EXA Conductivity & Resistivity Analysers

Size: px
Start display at page:

Download "EXA Conductivity & Resistivity Analysers"

Transcription

1 EXA Conductivity & Resistivity Analysers S C202 & S C402 Bulletin 12D7A2-E-H

2 Yokogawa s innovative online EXA analysers have long set the pace in measurement and control of liquid conductivity in many industries including electricity generation and chemical processing. Precision measurement of conductivity/resistivitiy is also required in industries where water quality is critical such as semi-conductors, pharmaceuticals and food processing. The EXA range of high-tech analysers has a proven track record in precision measurement, reliable performance especially under harsh environmental conditions, and offer great flexibility in measurement and output capabilities. This combination of features has made EXA analysers an industry standard. All analysers have built-in two-way communication for remote control, built-in diagnostics, and push button controls for quick and easy operation, programming and maintenance. Robust casings and mountings ensure the analysers are well protected for reliable performance under all types of environmental conditions.

3 Reliability is the key word in analyser systems: reliability in terms of accurate measurement and reliability in terms of continuous instrument operation with minimum maintenance. Reliability and low maintenance are thus the two main criteria for our customers in selecting different types of analyser systems for a process environment. But these two selection criteria do not rule out ease of use and multifunctions, both of which are important to our customers in selecting the best instrument for the job. The cost of defective measurements no matter how small can be inestimable in a process environment, especially if the error goes undetected. One of the most common sources of error, a cracked or fouled sensor, is notoriously difficult to pick up. Even redundant systems can give perfectly plausible readings despite a small defect in the sensor. Thus, reducing and eliminating this type of error has been and continues to be a major objective for Yokogawa s Process Analyser Division in the design of the EXA series of analyser systems.

4 The EXA range includes analysers with either a 2-wire or 4-wire transmitter for conductivity and/or resistivity measurement as well as a 4-wire dual cell conductivity analyser ( see Table ) A guide to choosing an online conductivity analyser to meet your specific requirements 2-wire 4-wire SC202 ISC202 SC402 DC402 ISC402 Conductivity range (µs)* 1 200, ,000, , , ,000,000 Resistivity range (Mohm) 0-50 none none Temperature Range -20 and 250 C -20 and 140 C -20 and 250 C -20 and 250 C - 10 and 130 C (4 to 482 F) (4 to 284 F) (4 to 482 F) (4 to 482 F) (14 to 266 F) Power VDC VDC 100/115/230 VAC 100/115/230 VAC 100/115/230 VAC 24 VDC 24 VDC 24 VDC Output 4 to 20 ma 4 to 20 ma 0 (4) to 20 ma 0 (4) to 20 ma 0 (4) to 20 ma twice twice twice Input 1 sensor 1 sensor 1 sensor 2 sensors 1 sensor Contacts none none Communication HART, FF, Profibus HART, FF, Profibus HART and 2-way HART and 2-way HART and 2-way 2-way with 2-way with with PCviewer with PCviewer PCviewer (HART) PCviewer (HART) Hazardous area certification ATEX / CSA / FM ATEX / CSA / FM no no no * Specific Conductivity range = Conductivity range * Cell constant (cm -1 ) More detailed information can be found in our General Specifications sheet. Please refer to the European web-site ( to contact your nearest representative. Remote control Users in the process industry want to be able to do more than just examine raw process data. Process engineers want two-way communication with the process in order to able to make timely adjustments to improve process accuracy, reduce waste and improve quality. All EXA analysers offer dynamic, real-time data exchange. The vital link for real-time monitoring is maintained via RS485/Hart protocol or FSK/HART/FF protocol (see Table 1). Windows 98- based PCviewer software enables remote access to critical data on PC screens in an office, maintenance workshop or control room. Logbook The automatic logbook function in PCviewer available on all EXA analysers can capture and store up to 100 user-selectable events, such as calibration and alarm records. The electronic logbook provides vital time and cost-saving information about predictive maintenance and system integrity. PCviewer software also enables remote reconfiguration of up to 15 analysers on a single, shielded, 2-wire cable. Furthemore, operators can adjust parameters and high/low levels, perform diagnostics, re-range outputs, reset setpoints and manipulate product and temperature limits. Equally important, remote troubleshooting eliminates time-consuming disassembly of the unit in the field.

5 Resistivity measurements The semiconductor and pharmaceutical industries have strict requirements for measurement and control of ultra-pure water flows. That s why Yokogawa has incorporated highly sensitive resistivity features and advanced temperature compensation into several of the EXA analysers (EXA SC402, SC202 and DC402; see Table 1). These analysers are highly sensitive to resistivity in ranges up to 18 Megaohm with repeatability and linearity of Megaohm for high-resolution monitoring. The system maintains accuracy of Megohm including temperature compensation using simple polynomial equations over the 0-80 C ( F) range. USP guideline Designed and built with these critical resistivity measurements in mind, EXA SC402 and SC202 analysers are available with titanium / SS sensors with adjustable insertion depth. These robust sensors are designed for pure-water applications where probes can be exposed to highly corrosive solutions during ion exchange regeneration. In monitoring water quality for pharmaceutical applications, the USP conductivity section 645 edition no. 23 guideline sets the maximum level for uncompensated conductivity and process temperature. SC202 and SC402 analysers can monitor water quality to this guideline and display uncompensated conductivity and process temperature. The USP curve is pre-programmed in the SC402 and SC202 analysers and is the alarm set point. A warning alarm can be set as a percentage of the USP value, and both analysers display a warning code when this trigger level is reached.

6 Self diagnostics From cooling tower to boiler feed water and condensate recovery processes, conductivity measurement and control are vital to the efficient operation of an electricity generation plant. Built-in diagnostics in the EXA analysers monitor the cell integrity and the scaling of sensors for immediate detection of a corrupted signal. Furthermore, built-in diagnostics can play an important role in plant maintenance and safety by helping ensure secure operation of water quality processes from the most concentrated acids and alkalis to de-ionised feed water, as well as monitoring condensate leakage. The easy-to-understand diagnostic signals include upscale and downscale ma outputs for sophisticated interface and control. Temperature compensation Outputs capabilities EXA analysers have a wide range of output capabilities, including PI control on both the contacts (only SC402) and current output. These output features can be harnessed to drive solenoid valves or feed pumps to create a costefficient and reliable control system for many small applications. A dedicated FAIL contact output immediately alerts users to any error in the measuring loop. Accurate conductivity measurement is critical in a reliable control strategy. The precision of these vital measurements is increased by the precision of the EXA SC402 and SC202 analysers because of a broad selection of temperature compensation options. Temperature compensation modes feature correction for ultra pure water and concentrated solutions according to NaCl tables, manual compensation, and automatic matrix temperature compensation (preprogrammed and user-definable) for the specific applications.

7 Universal mounting and compatibility Both the EXA SC402 and SC202 analysers have robust IP65 (NEMA 4X) housings suitable for field mounting in the harshest industrial environments and also for panel mounting in a control room. The flexible but durable polycarbonate faceplate window allows pushbutton programming and calibration while maintaining the weatherproof integrity of the enclosure. The EXA SC202 analyser is certified for hazardous area duty. On-line mounting adapters use compression fittings for easy maintenance, a crucial factor in any industry where process downtime is extremely costly. The SC402 and SC202 analysers are compatible with a wide range of Yokogawa and other sensors, whether for high concentration, phase-changing or pure water applications. Specially designed holders for the sensors are available from Yokogawa in a variety of metals and engineering plastics. Flow-through, immersion and retractable assemblies with JIS, EN, DIN or ANSI flanges are compatible with most process standards. Yokogawa quality certification All Yokogawa analysers are designed to meet rigorous ATEX (CE mark) requirements, and thus comply with the highest standards in design testing and manufacture. The approval of the Canadian Standards Association and the Factory Mutual (FM) Research Corporation bears further testimony to the Yokogawa quality commitment, especially in electromagnetic compatibility and noise immunity.

8 Dimensions SC (6.4) Unit: mm (inch) Dimensions SC (5.67) 16.5 (0.65) 180 (7) 30 (1.2) 144(5.67) 115.5(4.55) 92 (3.6) 115 (4.5) 24(1) Specifications SC202 Power supply : up to 40 VDC (Fieldbus Foundation model 9-32 volt) Outputs : 4-20 ma Measuring range: 0-2 S/cm Output Span : Conductivity : > 0.01µS/cm and < 1999 ms/cm (max 90% zero suppression) Resistivity : > kω/cm and < 999 MΩ/cm (max 90% zero suppression) Temperature : NaCl standard, programmable factor Compensation or 5 x 5 Matrix (pre-programmed or user- Defined) Specifications SC402 Power supply : 230, 115 or 100 VAC & 24 VDC Outputs : 2 x 4-20 ma, RS485, 4 x SPDT Relays Measuring range: 0-2 S/cm Output Span : Conductivity : > 0.01µS/cm and < 1999 ms/cm (max 90% zero suppression) Resistivity : > kω/cm and < 999 MΩ/cm (max 90% zero suppression) Temperature : NaCl standard, programmable factor Compensation or 5 x 5 Matrix (pre-programmed or user- Defined) Model Suffix Option Description SC202G...Conductivity Transmitter General Purpose version SC202S...Conductivity Transmitter Intrinsic Safe version Type -A...Milli-amp (+HART ) version -F...FOUNDATION Fieldbus version -N...Non-Incendive Milli-amp (+HART ) version -B...Non-Incendive FOUNDATION Fieldbus version IM -E...English language* Options /H...Hood for Sun Protection /U...Pipe & Wall mounting hardware /SCT...Stainless steel tagplate /Q...Calibration certificate /T...Turck Fieldbus connector * For other languages contact local sales office Model Suffix Option Description code code SC402G... Conductivity/resistivity transmitter -E... Always E Supply Volts 50/60 Hz voltage Volts 50/60 Hz Volts DC Volts 50/60 Hz Instruction manual -E... English language* Options /U... Pipe and wall mounting hardware /PM... Panel mounting hardware /Q... Quality certificate /SCT... Stainless steel tag * For other languages contact local sales office YOKOGAWA HEADQUARTERS 9-32, Nakacho 2-chome, Musashinoshi Tokyo 180 Japan Tel. (81) Fax (81) webinfo@mls.yokogawa.co.jp YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA United States Tel. (1) Fax (1) info@yca.com Yokogawa has an extensive sales and distribution network. Please refer to the European web-site ( to contact your nearest representative. YOKOGAWA EUROPE B.V. Databankweg AL AMERSFOORT The Netherlands Tel Fax info@nl.yokogawa.com YOKOGAWA ELECTRIC ASIA Pte. Ltd. 5 Bedok South Road Singapore Singapore Tel. (65) Fax (65) webinfo@yas.com.sg BU12D7A2-E-H Subject to change without notice. Copyright Printed in The Netherlands, (A)

Two global companies, one solution.

Two global companies, one solution. Two global companies, one solution. About the Partnership March 2002, Yokogawa Electric Corportation, Japan and Pepperl+Fuchs Germany signed a Global Preferred Vendor Agreement. Solutions found in this

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev. STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.1 Introduction Honeywell s STT 3000 family of microprocessor based smart

More information

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors Dräger Polytron 8100 EC Detection of toxic gases and vapors The Polytron 8100 EC is Dräger s top of the line explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2 APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,

More information

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2 APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer. The Process TDLS Solution New Features TDLS 200 Tunable Diode Laser Spectroscopy (TDLS) Analyzer Bulletin 11Y01B01-01E-A www.yokogawa.com/an/index.htm The first Tunable Diode Laser analyzer Innovative

More information

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0) Data Sheet 220 LEVEL MONITOR Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Model 220 Powered by 4-20mA loop Non-linear tank correction Four level alarms Level bar graph display

More information

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1 Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based

More information

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN. Pulp & Paper Pulp & Paper Instruments and for Pulp & Paper Industry LF3BUSS03-00EN www.yokogawa.com Pulp & Paper Plant for the World Process for Fundamental Materials, Requires Effective Production with

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

Electronic Pressure Digest. Pressure and Temperature Transmitters

Electronic Pressure Digest. Pressure and Temperature Transmitters Electronic Pressure Digest Electronic Pressure Digest Pressure and Temperature Transmitters R General Purpose Pressure Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.

Intelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E. Intelligent ph Converter PH400G PH400G Intelligent ph Converter Bulletin 12B7C1-01E www.yokogawa.com/an/ Places a multitude of functions at your fingertips EXA PH Intelligent ph Converter (Model PH400G)

More information

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS SECTION 40 75 16 INDUCTIVE CONDUCTIVITY ANALYZERS PART 1 General 1.01 SUMMARY A. Requirements for a digital inductive conductivity sensor for standard, hazardous and hightemperature applications. The sensor

More information

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full

More information

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/ Compact and lightweight 220g IP67 Waterproof Various Convenient Functions Data memory Alarm

More information

Toroidal Conductivity Transmitters Series APT4000 Specifications

Toroidal Conductivity Transmitters Series APT4000 Specifications Toroidal Conductivity Transmitters Series APT4000 Specifications 70-82-03-42 March 2001 Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,

More information

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance

More information

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 TC APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

Dew-Point Transmitters and Instruments

Dew-Point Transmitters and Instruments Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement

More information

Temperature Solutions Line Card

Temperature Solutions Line Card Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,

More information

Software Version 2.01 LEVEL MONITOR MODEL 220

Software Version 2.01 LEVEL MONITOR MODEL 220 Software Version 2.01 LEVEL MONITOR MODEL 220 19 April 2000 CONTENTS 1. Introduction 1 1.1 Model Number Designation 2 1.2 Intrinsic Safety Considerations 3 2. Specification 4 3. Operation 6 3.1 Display

More information

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8000 Stationary gas detector (EC) Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic

More information

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Weighing System Ronan Model X96S Series Weighing System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com Compact and lightweight 220g IP67 Waterproof CE,C-tick Compliance Various Convenient Functions

More information

I/A Series 716C 1/16 DIN Temperature Controller

I/A Series 716C 1/16 DIN Temperature Controller Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Personal ph, ph/orp, Conductivity Meters

Personal ph, ph/orp, Conductivity Meters Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/ Compact and lightweight 220g IP67 Waterproof CE,C-tick Compliance Various Convenient Functions

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD INGOLD Leading Process Analytics Transmitter Series M300 / M400 / M700 / M800 Transmitters Reliable Intelligent Diagnostics Versatile and Tailorable Easy Handling Intelligent Transmitter Series Tailor

More information

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement

More information

Maxline 2 Thermal Imaging Solutions for Manufacturing

Maxline 2 Thermal Imaging Solutions for Manufacturing Maxline 2 Thermal Imaging Solutions for Manufacturing For automated Process Control and Process Inspection applications IRCON Maxline 2 Thermal Imaging and Analysis Solutions The Maxline 2 infrared thermal

More information

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement Data sheet High Temperature Zirconia Oxygen Analyzer Superior technology and quality from the world leader in oxygen measurement User-friendly language options selectable system analysis comprehensive

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Polytron 7000 Detection of toxic gases and oxygen Dräger Polytron 7000 Detection of toic gases and oygen The Dräger Polytron 7000 is a gas detector that can satisfy many toic and oygen gas measurement applications on a single platform It meets the requirements

More information

Inductive Conductivity

Inductive Conductivity Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8310 Stationary gas detector (DSIR) Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Steam and Water Analysers

Steam and Water Analysers Steam and Water Analysers A Comprehensive Range for Steam and Water Analysis System (SWAS) ANALYTICAL INSTRUMENTS Energy Conservation Environment Process Efficiency www.forbesmarshall.com Steam and Water

More information

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C) Product Data Sheet December 2012 00813-0100-4027, Rev BB Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued R 37-01 Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Rosemount 4500 Hygienic Pressure Transmitter

Rosemount 4500 Hygienic Pressure Transmitter Product Data Sheet Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter Hygienic design conforms to 3-A and EHEDG standards Demonstrated best-in-class performance during SIP/CIP for process temperatures

More information

Proven Technology for Safety Instrumentation Systems

Proven Technology for Safety Instrumentation Systems Proven Technology for Safety Instrumentation Systems The ultimate solution - safety without compromise Bulletin 48B03A00-01E-E www.yokogawa.com/eu Bulletin 48A03A00-01E-H 280 mm Japan 297 mm A4 Europa

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Corporate Profile. needs and product demands. CON 08X /03 Rev 0 Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation

More information

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2 APT 2000 Series 2-Wire ph Transmitters 70-82-03-32 2/00 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

OMA-300 Process Analyzer

OMA-300 Process Analyzer A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance

More information

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Dissolved Oxygen Measurement liquisys M COM 223 / 253 Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS GENERAL INFORMATION Please read these instructions and keep them in a safe place. These instructions must

More information

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16 TraceTek TTSIM-1A TraceTek Sensor Interface Module with Relay Installation/OPERATION Instructions Approvals and Certifications TYPE NM General Signaling Equipment 76LJ Only AC versions are UL listed and

More information

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 4500 Hygienic Pressure Transmitter. Start Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and

More information

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2 H 2 S Ex p Ex d The world s safest continuous H 2 S analyzer. The OMA continuously measures H 2 S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the power of collateral data to

More information

Controller Specification Sheet

Controller Specification Sheet Controller Specification Sheet MC9550ABXXBX Proportional Inhibitor Dosing, Dual Conductivity Bleed Control, Dual Point ph Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS. SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone

More information

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER ISO-14001 ISO-9001 SPECIFICATION SHEET SILICA ANALYZER Model: SLC-1605 (for very low concentration) SLC-1615 (for low concentration) SLC-1625 (for high concentration) This equipment is used for high accuracy

More information

Series 5000 Hydrazine Analyzer Model 60002

Series 5000 Hydrazine Analyzer Model 60002 Series 5000 Hydrazine Analyzer Model 60002 T he patented* Series 5000 Hydrazine Analyzer is a continuous-reading instrument using the p-dimethylaminobenzaldehyde method of analysis for colorimetric measurement

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

UDC 700 Universal Digital Controllers and Indicator Specifications

UDC 700 Universal Digital Controllers and Indicator Specifications UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality

More information

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING POSITIONERS ELECTRO-PNEUMATIC INTELLIGENCE CONTROLS SERIES 6A FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS CELEBRATING The High Performance Company Y E A R S INTELLIGENCE Series 6A Intelligent Electro-Pneumatic

More information

General Specifications

General Specifications General Specifications Model GD402 Gas Density Meter Overview The Model GD402 gas density analyzer and Model GD40 detector not only provide continuous measurement of gas density, but also several other

More information

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

OIL FILM DETECTOR (Flame-proof Version) SODL-1600 OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Transmitters 3/01 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures ph or ORP in industrial processes

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Bionics Instrument. Alarm Handling. Gas Alarm Systems Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,

More information

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Data Sheet Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications Ideal for small gas/oil fired boilers Cost effective solution for OEM outlets with a quick return on end-user investment Continuous

More information

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 3051CFP Integral Orifice Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters

More information

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Analyzers 70-82-03-44 10/03 Page 1 of 8 Specification Overview The Honeywell Analytical Process Analyzer (APT) 4000 Series 2 continuously measures ph or ORP in industrial processes

More information

Ronan Model X96S Series Density System

Ronan Model X96S Series Density System Ronan Model X96S Series Density System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

Enraf Servo Gauge 854 ATG

Enraf Servo Gauge 854 ATG Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

Hydrazine Analyzer Series 2171 Specifications

Hydrazine Analyzer Series 2171 Specifications Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination

More information

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter PD685 Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter Actual Size Digits C US Intrinsically Safe 3½ Digits LARGE DISPLAY NEMA 4, Type 4X, IP67 Loop-Powered Field-Mount Process Meter 4-20 ma

More information

Altanium Temperature Controllers

Altanium Temperature Controllers Designed to provide the industry s most consistent part quality Benefits 2 to 254 zones of control Simple and intuitive operation Interchangeable cards and interfaces across the entire product line Active

More information

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE DSGH Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE Revision History Revision History Version of manual Description Date 1.0 Initial release 051025 1.1

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Technologies, Solutions, and Applications. Radiation-based Level

Technologies, Solutions, and Applications. Radiation-based Level Technologies, Solutions, and Applications Radiation-based Level Contents Leadership in Radiation-based Level 3 Principle of Operation 4 Models and Versions 6 Radiation-based Level in the plics System 8

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity Product Specifications PSS 6-1C1 F 873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity METAL ENCLOSURE VERSION MOUNTING HARDWARE NOT SHOWN EASY-TO-USE

More information

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001 OCX 4400 Product Data Sheet PDS 106-440.A01 February, 2001 Oxygen/Combustibles Transmitter Both oxygen and combustibles measurements in a single instrument Unique architecture - electronics mounted with

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E

OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102.  Bulletin 11M10A01-03E Limiting-current type Oxygen Analyzer OX00, OX02 OX00, OX02 Limiting-current type Oxygen Analyzer One Instrument measures 00 ppm to 25% Oxygen Simple "One Touch" Calibration Self Diagnostics Assure High

More information