OPERATING INSTRUCTIONS FOR:
|
|
- Nelson Davidson
- 5 years ago
- Views:
Transcription
1 OPERATING INSTRUCTIONS FOR: MODEL: BL-30 & BL-130 REFRIGERATED BATH Thermoline Scientific Equipment Pty. Ltd. ABN Ross Place Wetherill Park NSW P.O. Box 1851 Wetherill Park DC NSW 1851 Phone: (02) International: Fax: (02) International: thermoline@thermoline.com.au Web:
2 Introduction: Thank you for selecting this equipment from the large range of products manufactured & imported by Thermoline Scientific. This manual covers the operation, cleaning, & maintenance instructions for this equipment. Incorrect operation or use can cause harm or damage to the equipment, therefore it is very important that you read, understand, and implement the instructions, to ensure reliable operation. Please keep this manual in a safe place for future reference. LIST OF CONTENTS: INTRODUCTION: 2 LIST OF CONTENTS: 2 UNPACKING: 2 USE AND FUNCTION: 2 & 3 LOCATION & INSTALLATION: 3 & 4 Location: Level: Mains connection: Water supply & connection of external circuit: OPERATION: 4, 5, &6. Controls: Changing the temperature: CLEANING & MAINTAINANCE: 6 & 7 Calibration: 7,8 & 9 WARRANTY: 9 & 10 UNPACKING: Remove the equipment from the packing material and check for damage. Notify the detail of any damage to your supplier or to Thermoline Scientific without delay. Retain the packing materials until the equipment has been thoroughly tested. USE & FUNCTION: This precision circulated bath is ideal for applications where low temperature liquid is required, with a pump-out facility for liquid to be circulated through an external closed circuit. Operating temperature range is -5ºC to 100ºC. These baths will operate from a standard 240 volt, 50Hz, general purpose outlet (power point). BL-30L uses a 10 amp outlet, and the BL-130L uses a 15 amp outlet. Cooling is by means of a hermitically sealed refrigeration unit using environmentally friendly refrigerant
3 Features: Wide temperature range: -5ºC to +100ºC Built in heating and cooling systems. Drain valve for easy cleaning and changing of fluid. Pump out facility allows for closed loop heat exchange operation. 9 or 20 litre tank capacity. LOCATION & INSTALLATION: Location: All refrigerated equipment generates heat as part of the normal operation. It is vital for correct performance and reliability that adequate ventilation is provided to allow this heat to dissipate. Any refrigerated equipment that is operated in a small unventilated area, especially in warm weather, can cause the compressor to overheat and may result in premature failure. NOTE: Failure to observe ventilation guidelines will void the manufacturer s warranty! You will notice that there are ventilation slots on all sides of the base of the bath, make sure that none of these vents are blocked to ensure adequate air flow to dissipate heat generated by the refrigeration unit. Level: The refrigerated bath should be standing on firm level surface. Note: Because of the size the BL-130 is fitted with castors to allow for easy movement. Push down the tabs on the castors to restrict movement once the bath is in place. Mains connection: This bath is suitable for connection to a standard 240 volt, 50Hz, supply. A dedicated outlet should be used for the supply, do not use power boards or the like. A 3- pin moulded plug is fitted as standard to the mains lead. BL-30L uses a 10 amp outlet, and the BL-130L uses a 15 amp outlet. Water supply: The water bath should be filled with liquid to within 40mm of the top. This will ensure that the float switch safety device is covered (the heating will not work until the float switch is covered). CAUTION: When working at a temperature below +5 C, add an antifreeze such as Ethylene Glycol at the following rate: Range: +5 C to 5 C 15% Ethylene Glycol
4 Connection of external water fluid circuit: As previously mentioned, the refrigerated bath has a pump-out facility that allows cooled or heated liquid to be pumped through an external closed circuit. Fittings are provided at the rear of the equipment for water inlet and water outlet connections. The refrigerated bath is supplied with a flexible silicon rubber hose connecting the inlet to the outlet if the pump-out facility is not necessary. Fill the bath with to the correct level with water or water/glycol mix, making sure that the drain valve is not open. Connect the external liquid circuit to the fittings shown in the photograph below, use hose clamps if necessary: OPERATION: 1: Locate the refrigerated bath as previously described, and plug the mains lead into the power supply but do not turn the power on just yet. 2: Fill the bath as previously described to the correct level with the relevant fluid to suit the temperature range. 3: Connect external closed circuit as described, or if the pump-out facility is not being used, make sure that the flexible silicon rubber hose is connected between water inlet and water outlet. 4: Controls:
5 5: Temperature control: PV (process variable): SP (set point): This digital display is the actual temperature in the bath. This digital display is the set temperature in the bath. This button is used to enter changes to parameters and to move between functions. These arrows are used to move between, and to alter the numbers on the screen. 6: Power switch: This illuminated switch is used to turn on the temperature controls and the circulating pump. 7: Refrig. switch: This illuminated switch is used to turn on the refrigeration unit to allow cooling to take place. Please note that the refrigeration switch should be turned off when operating at temperatures above 40ºC. Operating the refrigeration system at temperatures above 40ºC may result in reducing the life of the compressor. Also note that the Power switch has to be turned on for the Refrigeration switch to work. 8: Water indicating light: This light is illuminated when the temperature control is calling for heating, and if the fluid level in the tank is below the height of the float switch, the float switch turns off the element and also turns off the water light. This is a safety feature that stops the heating in the bath until the fluid is at a safe level
6 9: Changing the temperature: Turn on the Power switch. The circulating pump will run immediately, and the temperature will go through a short warm up before displaying the set temperature (SP) on the lower display and the bath temperature on the top display (PV). Use the arrow to highlight the digit on the set temperature to be altered. Use the or arrows to increase or decrease the value. Press the button to enter the new temperature. The display will stop flashing when the new temperature is accepted. Turn on the Refrigeration switch to start the refrigeration system if cooling is required (Only at temperatures below 40ºC!) General cleaning: CLEANING & MAINTENANCE: The interior tank and exterior case can be cleaned using a soft cloth. Never use abrasive cleaners or scouring pads as these will scratch the surface and may result in corrosion. Never use caustic type cleaning agents. The bath can be emptied easily using the drain valve at the rear of the bath. This refrigerated bath has electrical components such as the temperature control and refrigeration condensing unit. These items should not be subjected to any levels of moisture. For example do not use a hose to wash down the circulator. Evidence of moisture entry into any electrical device will void the manufacturer s warranty! Maintenance: Apart from normal levels of cleanliness, it is important that the refrigeration condenser is kept clean and free from dust. Failure to keep the condenser clean could lead to higher temperatures, higher running costs, and often a failure of the compressor. A clean condenser is a critical factor in keeping the refrigeration system operating correctly. The condenser should be cleaned at least 3 monthly, in some dusty locations this may need to be more frequent. By monitoring the amount clogging due to dust, the frequency of cleaning can be adjusted to keep it clean. Manufacturer s warranty does not cover the failure of the compressor due to a blocked condenser. A yellow sticker is placed on the front of the bath above the condenser face. Use this sticker to maintain a schedule or record of when the condenser is cleaned
7 Procedure for cleaning the condenser: The condenser is located at the front of the bath. Access is gained by removing the front ventilation panel; this can be removed by unscrewing 2 screws. Turn off the power at the power point before cleaning the condenser! Using a stiff paint brush, carefully remove dust and dirt build-up from the condenser, ensuring that dust is not pushed back into the condenser fins. The use of a vacuum cleaner will help in cleaning up the dislodged material. The condenser fins may be sharp, take care to avoid personal injury by not directly contacting them with your hands! The fin material is thin and can be easily bent, take care not to flatten the fins as this may affect the efficiency of the condenser. Calibration of temperature control (should be performed only by qualified technician): There are a number of factors that will affect the accuracy of the temperature displayed in relation to the actual temperature inside the bath, these include the following: Bath temperature. (At higher or lower temperatures the heat loss from the bath will be greater). Viscosity of fluid in the bath. Use of the pump-out facility. If a heat exchanger is in use, the lines will need to be well insulated
8 Because of the above factors, it will be common to have an error between the temperature displayed (PV), and temperature measured in the bath by a certified instrument. For this reason the digital temperature control has a parameter that can be used to correct the temperature displayed, called the BS. In simple terms this BS adds or subtracts a correction value to the displayed temperature to make it read the correct temperature. Please note that the temperature control has many parameters that are factory preset to provide accurate stable temperature control through the temperature range. These parameters are normally locked to prevent accidental changes to other control parameters; therefore it is important that they are not altered during the calibration procedure! The BS correction parameter can be accessed by means of the following procedure: Press the button for at least 3 seconds. This will allow access to the instrument configuration parameters. Use the button to scroll through the various control parameters that make the temperature control work. You will note that you cannot alter any parameters at this stage because they are locked. Scroll through to the LOCK parameter and use the arrow to make this parameter 0. This will now allow the operator to alter the BS parameter. Note: do not alter any parameter other than BS! AL-1 AT OFF AT.BS 0.0 P I D ARW CT 2 BS LOCK
9 BS is used to adjust the PV value to make it read the true value when measured by a calibrated independent instrument. For example, if the PV display read 20.0ºC and a calibrated instrument measured the bath temperature at 20.5ºC; you would make BS = +0.5ºC using the up arrow. Don t forget to press to enter the value. Make the LOCK parameter 1 again before exiting the parameter configuration level by holding the button for a few seconds. The output of the temperature control will now adjust the bath to the correct calibrated temperature. WARRANTY: Have the following information available when you contact the service department: Model number and serial number. This is generally found on the exterior of the case in the form of a stick-on label. The company name, address, contact name, contact phone number. A brief description of the problem. All warranty claims must be reported to, and agreed to by a Thermoline representative prior to any work being carried out
10 Standard 12 month Warranty Thermoline Scientific Equipment Pty Ltd ABN ( Thermoline ) Thermoline warrants to the original purchaser that this product will perform to its product specification for a period of 12 months from date of purchase, provided that the installation of the product has been carried out in accordance with the latest version of the manufacturer's instructions and further provided that the use of the product complies with that specified in the relevant specification. Thermoline is not responsible for any loss or damage arising from incorrect usage, usage outside the suitability of the product as stipulated in the manufacturer's instruction, damage caused by accident, fire, flood, act of God or failure to properly install, operate or maintain the goods in accordance with the printed instructions provided. The following statement applies only to product sales that fall within the definition of a Consumer Sale set out in the Australian Consumer Law contained within the Competition and Consumer Act (Cth) 2012: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Notwithstanding the preceding clause and to the extent permissible by law, the liability of Thermoline is limited, in relation to the warranted product and at the option of Thermoline to: replacing the product or the supply of equivalent product; the repair of the product; the payment of the cost of replacing the product or of acquiring equivalent product; or the payment of the cost of having the product repaired. To the extent permitted by law, all other warranties whether implied or otherwise, not set out in this Warranty are excluded and Thermoline is not liable in contract, tort (including, without limitation, negligence or breach of statutory duty) or otherwise to compensate the Purchaser for: any increased costs or expenses; calibration/certification services; any loss of profit, revenue, business, contracts or anticipated savings; any loss or expense resulting from a claim by a third party; or any special, indirect or consequential loss or damage of any nature whatsoever caused by Thermoline s failure in complying with its obligations or the purchaser s failure due to accident damage, impact, misuse or negligence. The benefits given to the purchaser in this Warranty are in addition to other rights and remedies under a law in relation to the products or services to which this warranty applies. This warranty applies only to products purchased and installed in Australia and does not cover any consumable items e.g. filters, light globes, ultrasonic nebulizers. The warranty does not extend to labour and freight costs where the warranted product is located outside Australia. To make a warranty claim, contact Thermoline on or service@thermoline.com.au
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN
OPERATING INSTRUCTIONS FOR: MODEL: TGO-80W, 150W, 240W GLASSWARE DRYING OVEN Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationfor LABORATORY REFRIGERATOR MODEL TELR-145/ L/200L CAPACITY REVISION
for LABORATORY REFRIGERATOR MODEL TELR-145/200 145L/200L CAPACITY REVISION 10-8-17 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10/12 Ross Place Wetherill Park NSW 2164. P.O. Box 1851 Wetherill
More informationREFRIGERATED RECIRCULATORY COOLER
REFRIGERATED RECIRCULATORY COOLER MODEL INCLUDES: TRC-3000 Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline Scientific ABN 80 000 859 129 10-12 Ross Place. Wetherill Park N.S.W. 2164. Australia.
More informationfor PHARMACY REFRIGERATOR MODEL TPR SD/GD TPR-750/950 2 SD/GD TPR SD/GD 520, 750, 950, 1150 Ltr CAPACITY REVISION
for PHARMACY REFRIGERATOR MODEL TPR-520 1 SD/GD TPR-750/950 2 SD/GD TPR-1150 3 SD/GD 520, 750, 950, 1150 Ltr CAPACITY REVISION 10-8-17 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12
More informationWITH OMRON E5CC CONTROL
LABORATORY OVENS, FAN FORCED & GRAVITY CONVECTION. MODELS: TO-152G & TOH-152G TO-152F, TOH-152F & TO-235F TO-330F & TO-500F WITH OMRON E5CC CONTROL Thermoline Scientific Equipment Pty. Ltd. T/A Thermoline
More informationfor LABORATORY STORAGE FREEZERS MODELS TUF GD/SD, TUF GD/SD, & TUF GD/SD 520, 740, & 950 Litre CAPACITY REVISION
for LABORATORY STORAGE FREEZERS MODELS TUF-520 1-GD/SD, TUF-750-2-GD/SD, & TUF-950-2-GD/SD 520, 740, & 950 Litre CAPACITY REVISION 26-1-16 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12
More informationLABORATORY ILLUMINATED FLOTATION BATH
LABORATORY ILLUMINATED FLOTATION BATH MODELS INCLUDE: TFB-1 Thermoline Scientific Equipment Pty. Ltd. ABN 80 000 859 129 10-12 Ross Place Wetherill Park NSW 2164. P.O. Box 6862 Wetherill Park DC NSW 1851
More informationPHARMACY REFRIGERATOR INSTRUCTION MANUAL
1 PHARMACY REFRIGERATOR INSTRUCTION MANUAL FOR MODELS: 145/200/440/740 520/750/950/1150 Fitted with Dixell XR70 Controller REVISION 19/4/2018 (2.1) 2 PRE USE CHECKLIST Read this manual All packaging removed
More informationfor CLIMATRON GROWTH CABINET MODEL CLIMATRON 520 & 1100-DL/SL-H-CO 2 With Humidity, CO 2 & Touch screen Control REVISION
for CLIMATRON GROWTH CABINET MODEL CLIMATRON 520 & 1100-DL/SL-H-CO 2 With Humidity, CO 2 & Touch screen Control REVISION 26-01-16 Thermoline Scientific Equipment Pty. Ltd. T/AThermoline ScientificABN 80
More informationOWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)
OWNER S MANUAL Convair Tower Heater CTH09 (English) (CTH09) SAFETY General Safety Please read these instructions before using the heater and keep for future reference. This appliance is not intended for
More informationInstructIon Manual KrEs EQuIPMEnt stands
Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available
More informationETLW7. Product: 7kg Top Load Washing Machine. User Manual
User Model Manual: Code/s: ETLW7 Product: 7kg Top Load Washing Machine Document: 1 User Manual Dear Customer, Congratulations on purchasing your washing machine. The Esatto brand is proudly distributed
More informationR A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL. TT-MTM Wall Controller
R A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL TT-MTM Wall Controller TT-MTM Wall Controller Rev B JUL12 TT-MTM wall controller This controller is a custom designed
More informationPRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote
PRODUCT MANUAL TT-MTM2 Hard-Wired Controller with Remote TT-MTM2 Hard-Wired Controller with Remote Rev D JUN16 TT-MTM2 Wall Controller This controller is a custom designed and manufactured controller for
More informationOperating Manual Refrigerated Display Cabinet
Operating Manual Refrigerated Display Cabinet This manual covers the Installation, Operation and Routine Maintenance requirements for the following Topaz Refrigeration product: HTS2GDCB, LTS2GDCB, HTM145GDCB,
More informationCamping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET
Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET Safety Information: Take care when moving and using the Camping Toilet Ensure that
More informationINSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA
INSTRUCTION MANUAL / INSTALLATION MANUAL 7kg Vented Dryer MODEL: KA7VENTDRYA THIS PAGE IS INTENTIONALLY LEFT BLANK 2 CONTENTS Safety Instructions 4 Your Kogan Vented Dryer 5 Before First Use 5 Accessory
More informationCUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2
CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2 STUART MANUFACTURING 1 Jayelem Crescent Padstow NSW 2211 Australia Telephone (02) 9773 3711 Fax
More information70L FRIDGE USER MANUAL
70L FRIDGE USER MANUAL SCD-70L Please read and understand this manual completely before using this product. SAFETY INFORMATION: Do not operate the fridge if it is visibly damaged. The fridge may only be
More informationBlade Series Heat Exchanger Operation and Installation
Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information
More informationRSA2CL6SS model pictured
Issue: 1 Description: Model Numbers: ROBINHOOD SLIDEOUTS RSA2CL6SS RSA2CL9SS RSA2CL6SS model pictured 1 Overview * All dimensions shown above are in mm and apply to 600mm and 900mm models Pre-installation
More informationREFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual
REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual For service information call 800-544-3057 Please have the following information available before calling. Information can be found on
More information45L & 60L FRIDGE USER MANUAL
45L & 60L FRIDGE USER MANUAL BCD-45L & BCD-60L Please read and understand this manual completely before using this product. SAFETY INFORMATION: Do not operate the fridge if it is visibly damaged. The fridge
More informationTable of Contents. Features Quality Policy Section A - Unit Operation Section B Unit Maintenance Trouble Shooting Guide...
Table of Contents Features... 3 Quality Policy... 3 Section A - Unit Operation... 4 Section B Unit Maintenance... 6 Trouble Shooting Guide... 7 Wiring Diagram... 9 Section C Unit Installation... 9 Unit
More informationWARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at
WARRANTY BOOKLET EHPA Electric Heat Pump Water Heaters Register online at www.rinnai.com.au Rinnai EHPA Series Electric Heat Pump Water Heater Product Warranty Warranty Terms The warranty terms in this
More informationOPERATION & MAINTENANCE INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz
RV Products Division OPERATION & MAINTENANCE INSTRUCTIONS FOR 230/240 VAC, 1ø, 50Hz 47000 SERIES RV ROOF TOP AIR CONDITIONER/HEAT PUMP AND REMOTE CONTROLLER Service Contact: Coast to Coast RV Services
More informationWatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)
WatchDog NXT60 Installation and Operations Manual Seaira Global, LLC 14021 NC Highway 50 Surf City, NC 28445 (910) 660-0962 Table of Contents Important Notes 2 Warranty Registration 2 Specifications 3
More informationTable of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...
Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Section B Unit Maintenance... 6 Trouble Shooting Guide... 6 Wiring Diagram... 7 Section C Unit Installation...
More informationModel pictured: ST6001
ST6001 Issue: 1 Description: ROBINHOOD SUPERTUB SGL DRW Model Number: ST6001 All dimensions in mm Model may vary slightly from images pictured Model pictured: ST6001 1 Overview Contents of packaging: 1
More informationLABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F
0 LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F WITH WEST 6100 CONTROL 1 IMPORTANT INFORMATION This manual contains operating
More informationPRODUCT MANUAL. The intelligent, energy saving solution
PRODUCT MANUAL The envirotouch is a range of intelligent, timer based switches which allows easy, point-of-use control of lighting and electrical devices. It includes multiple pre-set, countdown timer
More informationModel pictured: ST3701
ST3701 Issue: 1 Description: ROBINHOOD SUPERTUB CLASSIC SHDL Model Number: ST3701 All dimensions in mm Model may vary slightly from images pictured Model pictured: ST3701 1 Overview Contents of packaging:
More informationOWNER S MANUAL Compact Portable Refrigerated Air Conditioner CP35CW1
OWNER S MANUAL Compact Portable Refrigerated Air Conditioner (ENGLISH) () CONTENTS INTRODUCTION 1 SAFETY 2 COMPONENT LOCATION 3 INSTALLATION 4 CONTROL AND DISPLAY 5 REMOTE CONTROL 6 OPERATION 7 MAINTENANCE
More informationInstruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.
Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety
More informationICS PACIFIC. Installation Instructions & User Manual. G135L Medical Refrigerator
ICS PACIFIC G135L Medical Refrigerator Installation Instructions & User Manual 31 Healey Road, Dandenong South, Victoria, 3175, Australia P.O. Box 4140, Dandenong South BC, Victoria, 3164, Australia E-
More informationHorizontal Bottle Cooler Installation and Operation Manual
Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,
More informationSTEAM WALLPAPER STRIPPER MODEL HTW5
STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,
More informationTable of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...
Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Setting the Timer... 6 Typical Loading System... 8 Section B Unit Maintenance... 9 Trouble Shooting
More informationMASTERCOOL (MIC, MICH)
OWNER S MANUAL Portable Evaporative Cooler MASTERCOOL (MIC, MICH) ILL863-A ILL1222-A ILL863-A MEGACOOL (MIV, MIVH) MILLENIA (MI, MIH) (English) (MI MIH MIC MICH MIV MIVH) CONTENTS SAFETY... 1 General Safety
More informationOWNER S MANUAL. CoolTower CTF07. (English) (CTF07)
OWNER S MANUAL CoolTower CTF07 (English) (CTF07) SAFETY General Safety Please read these instructions before using the fan and keep for future reference. This appliance is not intended for use by persons
More informationDrying Cabinet With Timer
Malmet (Australia) Pty Ltd Head Office & Customer Service 9-11 McKay Avenue PO Box 373 LEETON NSW 2705 Phone: (02) 6953 7677 Email: inquiries@malmet-aus.com.au ABN 95 001 717 791 Operation, Maintenance
More informationUse and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC
Use and Care Manual Flammable Material Storage Refrigerator LRBFS06W1HC 7085 471-00 Table of Contents Table of Contents Page Please Read and Follow these Instructions... 2 California Proposition 65...
More information12L DEHUMIDIFIER OPERATING INSTRUCTIONS
12L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 12L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating
More informationPoolSweepa Wallclima / Optima Pool Cleaners. Operating Instructions
PoolSweepa Wallclima / Optima Pool Cleaners Operating Instructions 8151634 PoolSweepa Wallclima / Optima Pool Cleaners Operating Instructions Contents 1. INTRODUCTION... 2 2. SPECIFICATIONS... 2 3. WARNINGS
More informationIndustrial Vacuums, Inc
Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances
More informationOperation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA
HIGH MID LOW DRY FAN COLL HEAT TIMER SLEEP SWING Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA F C This appliance shall be installed in accordance with: Manufacturer
More informationINSTALLATION MANUAL Wolfen Slimline Hand Dryer Stainless Steel. Installation Details Warranty
INSTALLATION MANUAL 2039655 Wolfen Slimline Hand Dryer Stainless Steel Installation Details Warranty IF AFTER CHECKING THE INSTALLATION INSTRUCTIONS AND IMPORTANT INFORMATION, THE PROBLEM HAS NOT BEEN
More informationGeneral Care and Safety Guide
General Care and Safety Guide Thank you for choosing a Goldair Select Dehumidifier. This Goldair Select appliance has been designed and manufactured to high standards of engineering and with proper use
More informationFTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00
FTC-350A Flow Through Cooler Thermo NESLAB Manual P/N 002679 Rev. 11/08/00 Instruction and Operation Manual ual FTC-350A Flow Through Cooler Instruction and Operation Manual PREFACE SECTION I Safety SECTION
More informationWARRANTY BOOKLET. Commercial Hot Water. Register online at
WARRANTY BOOKLET Commercial Hot Water Register online at www.rinnai.com.au Rinnai Commercial Water Heating Products Warranty Warranty Terms The benefits to the consumer given by this warranty are in addition
More informationModel pictured: ST7001SLIM/ST7001SLIMA
ST7001SLIM Issue: 2 Description: ROBINHOOD SUPERTUB DBL DRW SLIM Model Number: ST7001SLIM / 7001SLIMA Model pictured: ST7001SLIM/ST7001SLIMA All dimensions in mm Model may vary slightly from images pictured
More informationTRAVELMATE. Instruction Manual
Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety Instructions carefully before using your refrigerator.
More informationInstruction Manual. By Evakool. Please read these instructions and the Safety section carefully before using your refrigerator.
Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety
More informationVX SERIES Wireless Thermostat with Occupancy Sensor
VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat
More informationRTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual
RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators NESLAB Manual P/N 013529 Installation, Operation and Service Manual RTE-5 & RTE-9 Bath and Circulator Instruction and Operation Manual Table of Contents
More informationTRAVELMATE FRIDGE FREEZER Instruction Manual
Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read these instructions and the Safety section carefully before using your refrigerator. 1.Safety
More informationInstallation and Operating Instructions for Microlene Underbench System
Installation and Operating Instructions for Microlene Underbench System WARNING : Microlene underbench system installation must be in compliance with all local legislative requirements, and installed by
More informationDigital Refrigerator/Freezer Thermometer model 00986
Instruction Manual Digital Refrigerator/Freezer Thermometer model 00986 CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensors... 2 Features &
More informationMini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems
SumpMaster Mini Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems Please pass these instructions on to the operator of this equipment. 1 DSM-Mini-0.4 = 10A combined Max DSM-Mini-0.75
More informationRHPK3000_IB_FA_ SALT & PEPPER MILLS 2 YEAR WARRANTY RHPK3000
RHPK3000_IB_FA_160115 SALT & PEPPER MILLS 2 YEAR WARRANTY RHPK3000 INSTRUCTIONS 1 & WARRANTY Congratulations on the purchase of your Russell Hobbs appliance. Each unit is manufactured to ensure safety
More informationUSER MANUAL RANGE HOOD CG920FGS. User manual_cg920fgs 28/11/2012
USER MANUAL RANGE HOOD CG920FGS 2 4 5 8 8 9 10 11 DESCRIPTION OF YOUR RANGEHOOD RANGEHOOD DIMENSIONS 1 2 20mm 280mm 540mm Min 820 Max 110mm 4 54mm 5 6 500mm 7 500mm 900mm Fig.4 8 Fig. Components list 1.
More informationSMOOTH FINISH CERAMIC 2 YEAR WARRANTY S3505AU USE & CARE MANUAL. To register your product go to
SMOOTH FINISH CERAMIC USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au www.remington.co.nz 2 YEAR WARRANTY S3505AU 1 IMPORTANT SAFEGUARDS Warning:
More informationH-16.5 Record Cleaning Machine Setup and Instruction Manual
H-16.5 Record Cleaning Machine Setup and Instruction Manual VPI INDUSTRIES, INC., 77 CLIFFWOOD AVE., #3B, CLIFFWOOD, NJ 07721 PHONE: 1-732-583-6895, FAX: 1-732-946-8578 http://www.vpiindustries.com 1 Table
More informationPoolSweepa FloorCova Pool Cleaner. Operating Instructions
PoolSweepa FloorCova Pool Cleaner Operating Instructions 8151633 PoolSweepa FloorCova Pool Cleaner Operating Instructions Contents 1. INTRODUCTION...2 2. SPECIFICATIONS...2 3. WARNINGS AND CAUTIONS...2
More informationPoolSweepa FloorCova Pool Cleaner. Operating Instructions
PoolSweepa FloorCova Pool Cleaner Operating Instructions 8151633 PoolSweepa FloorCova Pool Cleaner Operating Instructions Contents 1. INTRODUCTION...2 2. SPECIFICATIONS...2 3. WARNINGS AND CAUTIONS...2
More informationProduct & Assembly Manual
Product & Assembly Manual HEATSTRIP Intense Portable Electric Heater Model THY2200P For HEATSTRIP Installation video go to: www.youtube.com, search HEATSTRIP www.heatstrip.com.au Contents Manual # Rev
More informationPRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater
PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL Indoor Convective Panel Heater CONTENTS Rev A NOV14 1. Product Overview 2. Specification Data 3. Operations 4. Installation 5. Safety 6. Maintenance
More informationUSER MANUAL. Adventure Kings 50L Refrigerator
Adventure Kings 50L Refrigerator USER MANUAL Please read and understand these instructions and the safety information section before using your refrigerator. CONTENTS Safety Information 1 Notes on using
More information20L Electronic Dehumidifier
Operating Instructions 20L Electronic Dehumidifier Attention: This Dehumidifier is rated to extract 20L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard
More informationOWNER S MANUAL. ClimateMaster Portable Refrigerated Air Conditioner. (English) (CM9CW1)
OWNER S MANUAL ClimateMaster Portable Refrigerated Air Conditioner (English) (CM9CW1) CONTENTS Introduction... 1 Safety... 2 Component Location... 3 Installation... 4 Control and Display... 5 Remote Control...
More informationIssue 1 ROBINHOOD ISLAND CANOPY 90CM. Product may vary slightly from the picture
Issue 1 Description: Model Numbers: ROBINHOOD ISLAND CANOPY 90CM RIE3CL9SS Product may vary slightly from the picture Pre-installation Thank you for purchasing a quality Robinhood rangehood. Robinhood
More informationOPERATION, INSTALLATION AND MAINTENANCE MANUAL. THX Flush Mount Enclosure. Take heating to the Max!
OPERATION, INSTALLATION AND MAINTENANCE MANUAL THX Flush Mount Enclosure Take heating to the Max! Mounting options Rev C MAR16 The installation of HEATSTRIP Max is simple and easy with the standard mounting
More informationModel pictured: RCB2AH6WH/SS
RCB Issue: C Description: ROBINHOOD COMPACT CANOPY Model Numbers: RCB2AH6WH, RCB2AH6SS, RCB2AH9WH, RCB2AH9SS Model pictured: RCB2AH6WH/SS All dimensions in mm Model may vary slightly from images pictured
More informationThermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13
Installation Manual Thermostat Series TSTBM-RRS--TW-A Remote Temperature Sensor (Requires TSTBM3H2CPH6W-A) TSTBM-RRS--TW-A 2 TSTBM-RRS--TW-A Table Of Contents Table of Contents Thermostat Quick Reference...
More informationWALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL
WALL MOUNT ELECTRIC FIREPLACE EF-BLT13-36 EF-BLT13-42 EF-BLT13-50 EF-BLT13-60 OWNERS MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 120-VOLT
More informationWARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at
WARRANTY BOOKLET Hotflo (HFE) Series Electric Storage Water Heaters Register online at www.rinnai.com.au Rinnai Hotflo (HFE) Series Electric Water Heating Product Warranty Warranty Terms The warranty
More informationSILK CERAMIC STRAIGHTENER
SILK CERAMIC STRAIGHTENER USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au SILK CERAMIC PLATES 240 C FAST HIGH HEAT 3 YEAR WARRANTY S9600AU 1 IMPORTANT
More informationMariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.
MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including
More information2.9kW Portable Air Conditioner
Operating Instructions 2.9kW Portable Air Conditioner Item: GCPAC210 General Care and Safety Guide Thank you for choosing this Goldair product. This Goldair appliance has been designed and manufactured
More informationINSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling
INSTRUCTION MANUAL TS21 2 Heating and 1 Cooling WELCOME TO Flexible applications - Universal and easy to install in residential or commercial environments. Advanced features - Precision electronics provide
More informationTurbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely
More informationProduct Manual. Argon (AMC 1020)
Product Manual Argon (AMC 1020) CONTACT US: Forme Medical Pty Ltd 11 Frankston Gardens Drive, Carrum Downs, Victoria 3201 AUSTRALIA Phone: 03 9708 2661 Web: www.formemedical.com.au ABN: 48 154 618 014
More informationInstruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.
Nexberg Pty Ltd T/a Evakool 16 Enterprise St CALOUNDRA QLD 4551 Tel : 07 5492 7777 Fax : 07 5492 7733 Please read this manual and the Safety Instructions carefully before using your refrigerator. 1. Safety
More informationDear Valued Customer:
Dear Valued Customer: Thank you for purchasing CARON Products & Services equipment. We appreciate your business and look forward to being your preferred supplier of controlled environment equipment products
More informationThermometer model 02059
Instruction Manual Thermometer model 02059 pm CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2 Features & Benefits: Sensor... 2 Features & Benefits: Display... 3 Setup...
More informationPress the Manual / Automatic select button and then choose the desired parameters according to the following table:
Press the Manual / Automatic select button and then choose the desired parameters according to the following table: Cleaning cycle indicator This determines the length of the cleaning cycle. Fast -hour
More information8L DEHUMIDIFIER OPERATING INSTRUCTIONS
8L DEHUMIDIFIER OPERATING INSTRUCTIONS Attention: This Dehumidifier is rated to extract 8L per day in an environment of 80% humidity and temperature of 30 C. This is the world-wide standard for rating
More informationINSTRUCTION MANUAL P Heating and 1 Cooling
REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION www.totaltouch.info Technical Support: 1-866-90TOUCH (1-866-908-6824) INSTRUCTION MANUAL P286-1200 2 Heating and 1 Cooling Physical Dimensions Case:
More informationCARE & MAINTENANCE ALUMINIUM WINDOW & DOOR SYSTEMS BY
CARE & MAINTENANCE ALUMINIUM WINDOW & DOOR SYSTEMS BY FRONT COVER: MELBOURNE MODERN ARCHITECT CANNY ARCHITECTURE WINDOWS BY WINDOWS BY DESIGN PHOTOGRAPHY BY REBEKAH JEWEL CONGRATULATIONS ON PURCHASING
More informationHumidity Monitor model 01080
Instruction Manual Humidity Monitor model 01080 Features & Benefits 19 18 1 2 3 4 12 11 10 17 16 5 9 RECORDS ºC/ºF 15 14 FRONT 6 7 8 1. Humidity Level Indicator Indicates a high, low or ideal humidity
More informationPRO BIG CURLS 2 YEAR WARRANTY CI5338AU USE & CARE MANUAL. PRO CERAmIC TECHNOlOGy 30 PRO HEAT SETTINGS PLEASE READ PRIOR TO USE
PRO BIG CURLS USE & CARE MANUAL PLEASE READ PRIOR TO USE PRO CERAmIC TECHNOlOGy 30 PRO HEAT SETTINGS 2 YEAR WARRANTY CI5338AU 2 IMPORTANT SAFEGUARDS Warning: Do not use this appliance near bath tubs, showers,
More informationTo get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.
User s Guide BS116 Thank you for purchasing the VACMASTER BS116 Impulse Bag Sealer. You are about to advance your operation with one of the most reliable sealers available. The BS116 is a fully automatic,
More informationDuct Mount. Installation Instructions
Duct Mount Installation Instructions 00809-0600-4975 Legal Notice The Flame Detector described in this document is the property of Rosemount. No part of the hardware, software, or documentation may be
More informationPlatinum Series Electronic Panel Heaters
Operating Instructions Platinum Series Electronic Panel Heaters Models: GPPH500, GPPH510, GPPH520, GPPH530 General Care and Safety Guide Thank you for choosing a Goldair Panel Heater. This Goldair Heater
More informationVOLUME UP STRAIGHTENING BRUSH
VOLUME UP STRAIGHTENING BRUSH Creates voluminous, smooth styles in minutes USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au www.remington.co.nz 2
More informationSPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax
SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts
More informationPERFECT CURLS 2-IN-1
PERFECT CURLS 2-IN-1 USE & CARE MANUAL PLEASE READ PRIOR TO USE To register your product go to www.remington-products.com.au www.remington.co.nz 2 YEAR WARRANTY CI63E1AU IMPORTANT SAFEGUARDS Warning: When
More informationProfessional Warming Drawer and Warming Drawer Cabinet
Professional Warming Drawer and Warming Drawer Cabinet Care & Use/Installation Instructions Models: (C)VQEWD5300SS (C)VQEWD5420SS IMPORTANT SAFETY INSTRUCTIONS WARNING: Read this manual carefully and completely
More informationInstallation and Operations Manual
Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More information