Field Top Mounted Condensing Unit
|
|
- Collin Spencer
- 5 years ago
- Views:
Transcription
1 Field Top Mounted Condensing Unit INSTALLATION & OPERATIONS MANUAL RF/RF-N, RM/RM-N IMPORTANT Keep in store for future reference!
2 REVISION HISTORY VERSION 1.0 New manual This manual is specific to the field top mounted condensing unit. For standard display case, please refer to standard case installation & Operations Manual.
3 TABEL OF CONTENTS GENERAL INFORMATION... 4 Safety Notice General Information INSTALLATION... 5 Condensing Unit Pump Evaporating Heater Pan Condensing Unit Cover ELECTRICAL Wiring Diagrams OPERATION Control Setting APPENDIX... RF/RF-N Electrical Data & Case Dimensions RM/RM-N Electrical Data & Case Dimensions
4 GENERAL INFORMATION SAFETY NOTICE All warning messages will inform you of the potential hazard; how to reduce the risk of case damage, personal injury or death; and what may happen if the instructions are not properly followed. DANGER Indicate[s] a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicate[s] a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicate[s] a hazardous situation which, if not avoided, could result in minor or moderate injury. GENERAL INFORMATION STORE CONDITIONS Cases are designed to operate in an air-conditioned store that maintains a 75 F (24 C) store temperature and 55% (max) relative humidity. Case operation will be adversely affected by exposure to excessively high ambient temperatures and/or humidity. ANSI/NSF-7 Type I Display Refrigerator / Freezer Intended for 75 F / 55%RH Ambient Application REFRIGERATION SYSTEM OPERATION Adequate ventilation must be provided to dissipate rejected heat from the top of unit for proper performance. Clearance between top of Condensing unit covers and ceiling should be more than 30. EXTERIOR LOADING Do not walk on top of merchandisers. It could damage the cases and serious personal injury could occur. They are not structurally designed to support excessive external loading such as the weight of a person. Do not place heavy objects on the merchandiser. SERIAL NUMBER LOCATION The serial number is located in left top inside of cabinets. SHIPPING DAMAGE All equipment should be thoroughly examined for shipping damage before and during unloading. Any claim for loss or damage must be made to the carrier. The carrier will provide any necessary inspection reports and/or claim forms. Claims for obvious damage must be noted on either the freight bill or the express receipt and signed by the carrier's agent; otherwise, the carrier may refuse the claim. If damage becomes apparent after the equipment is unpacked, retain all packing materials and submit a written request to the carrier for inspection within 14 days of receipt of the equipment. LOST/MISSING ITEMS Any claim for missing items must be made to Texaking within 48 hours of receipt of the equipment.
5 INSTALLATION WARNING Refrigeration lines are under pressure and should be depressurized before attempting to make any connections. Always wear safety glasses and protective gloves when working with refrigerants. Contact with refrigerant may cause injury. Disconnect pipes with extreme caution. All pipes may contain liquid refrigerant under high pressure. Avoid breathing refrigerant and lubrication vapor or mist. Exposure may irritate eyes, nose and throat. If accidental system discharge occurs, ventilate work area before resuming service. Be sure that any room where you are working is thoroughly ventilated, especially if a leak is suspected. Refrigerant vapor is hazardous to your health and can cause death. CONDENSING UNIT 1) Open Condensing Unit Package CABLE TIE (6) CONDENSING UNIT PIPE INSULATION (2) MOUNTING SCREW (4) WASHER (4)
6 INSTALLATION CONDENSING UNIT 2) Mount Condensing Unit on top of the case. d b b a d c a c Place Condensing Unit on the top of the case, using provided Mounting Screws and Washers. Make sure to mount Condensing Unit at the corresponding location, so that the quick connects are facing each others. Front View After Mounting Back View After Mounting d c a b
7 INSTALLATION CONDENSING UNIT 3) Wiring-Power 1 ELECTRONIC UNIT CONTROLLER (EUC) Step 1: Find wires covered with conduit for condensing unit. It should be 2 yellows (male and female), red, black, and green. ELECTRICAL BOX COVER 2 Step 2: Remove screws to remove electrical box cover. Step 3: Pass through wires to the hole of electrical box of the Condensing Unit. 3
8 INSTALLATION CONDENSING UNIT CONDUIT WASHER CONDUIT GROUND TERMINAL 5 BLACK TO CONTACTOR (BLACK, RED) TO ELECTRONIC UNIT CONTROLLER (EUC) (YELLOW-MALE) (YELLOW-FEMALE) TO GROUND TERMINAL (GREEN) CONTACTOR 4 Step 4: Tighten the Conduit Washer to anchor to the electrical box of Condensing Unit. Step 5: Connect power supply wires (black and red) to the contactor, and green wire to the ground terminal.
9 INSTALLATION CONDENSING UNIT 4) Wiring-EUC 1 EUC 2 CONTROLLER BRACKET #17 #14 Step 1: Pop out the controller bracket. Step 2: Locate terminal #14 and #17 connection of EUC. Step 3: Disconnect #14 and #17 terminal connection. 3 (EUC) #17 #14
10 INSTALLATION CONDENSING UNIT 4 #17 #14 TO ELECTRONIC UNIT CONTROLLER (EUC) (YELLOW-MALE), (YELLOW-FEMALE) YELLOW YELLOW Step 4: Find male and female yellow wires from the conduit. Connect female terminal to #17 male terminal, and male terminal to #14 female terminal. Step 5: Complete wiring of EUC. Close the controller bracket and electrical box cover. 5 #17 YELLOW YELLOW #14
11 INSTALLATION CONDENSING UNIT 5) Quick Connects Step 1: Find quick connects on the back of the unit. Step 2: Mount the condensing unit with quick connects facing each other. Step 3: Remove the quick connects cover. Step 4: Align and pre-lubricate the quick connects. Step 5: Tighten coupling connections with hand first. Use a torque wrench to tighten the quick connect couplings to these settings to get a leak proof seal. Step 6: Use piece of insulation provided to cover quick connect coupling of the suction pipe. Cable ties are also provided.
12 INSTALLATION PUMP 1) Find Pump and T-Trap assembly parts. PUMP ADAPTOR T-TRAP HOSE (4ft) CABLE TIE (2) PUMP PUMP BUCKET T- TRAP ADAPTOR T- TRAP 2) Assemble T-trap to the case Step 1: Tighten T-trap to the drain at the bottom of the case. Step 2: Assemble T-trap adaptor and T-trap hose. Step 3: Run T-trap hose through the base to the desired pump location.
13 INSTALLATION PUMP 3) Pump installation. PUMP HOSE BACK OF THE CASE 4 Step 4: Tighten Pump Adaptor to the pump, followed by Pump Hose running from the back to the bottom of the case. PUMP HOSE T-TRAP HOSE Step 5: Locate the Pump Bucket at the desired pump location, and place the Pump inside. Step 6: Run T-trap Hose to the Pump Bucket, and secure using cable ties. Step 7: Make sure T-trap hose is 2 inches above from the floor of the Pump Bucket, to avoid blocking the drain path.
14 INSTALLATION PUMP 8 9 Step 8: Make sure to open the breath nose (red cap). Step 9: Plug power to the receptacle, which can be found on bottom left of the case.
15 INSTALLATION CONDENSATE PAN HEATER ASSEBLY 1) Find Condensate Pan Heater assembly parts PUMP HOSE SCREW (4) HOSE CLAMP CONDENSATE PAN HEATER 2) Install Condensate Pan Heater PUMP HOSE Step 1: Place the Condensate Pan Heater at appropriate location at the top of the case. Step 2: Mount the Condensate Pan Heater with screws provided. Step 3: Tighten the Pump Hose and Condensate Pan Heater connection using Hose Clamp.
16 INSTALLATION CONDENSATE PAN HEATER ASSEBLY 3) Wiring Condensate Pan Heater. Step 4: Find power supply wire of the Condensate Pan Heater. Make sure folk terminals are applied to black and red wires. RED BLACK Step 5: Pass power supply wires through the second hole of the electrical box. Step 6: Connect wires as shown above.
17 INSTALLATION Condensing Unit Cover
18 ELCTRICAL FIELD WIRING Field wiring must be sized for component amperes stamped on the data label in left top inside of case. Electrical hookups are made to a junction box located at top of case WIRING DIAGRAM Junction Box mounted top RF/RF-N Model
19 ELCTRICAL WIRING DIAGRAM Case RF/RF-N Model
20 ELCTRICAL FIELD WIRING Field wiring must be sized for component amperes stamped on the data label in left top inside of case. Electrical hookups are made to a junction box located at top of case WIRING DIAGRAM Junction Box mounted top RM/RM-N Model
21 ELCTRICAL FIELD WIRING Field wiring must be sized for component amperes stamped on the data label in left top inside of case. Electrical hookups are made to a junction box located at top of case WIRING DIAGRAM Case RM/RM-N Model
22 OPERATION
23 APPENDIX Condensing Unit Electrical Data Fans (120V) Lighting Data (120V) Refrigeration Data Defrost Data (208V) 2 door 3 door 4 door 5 door Fans Per Case Amps Watts LED Lighting 2 door 3 door 4 door 5 door Anthony OptiMax Pro Amps Watts Frozen Food Ice cream Evaporator ( F) Discharge Air ( F) Superheat Set point at Bulb ( F) 3~5 3~5 BTU/door Parallel Conventional Parallel Conventional door 3 door 4 door 5 door RF/RF-N MODELS Top Field Mounted Condensing Unit 2 door 3 door 4 door 5 door Condensing Unit Model FFAP-015Z-CFV-072 FFAP-022Z-CFV-071 FFAP-022Z-CFV-071 FFAP-022Z-CFV-071 Refrigerant Charge (R404a, lbs) Electrical Rating 115V/208V-1PH-60Hz : Red & Black power, white neutral, green ground MOCP (amps) MCA (amps) Notes: 1. MOCP: Maximum over-current protection, Including condensing unit and condensate removal system. 2. MCA: Minimum circuit ampacity, Including condensing unit and condensate removal system Defrsot Heaters (208V) Electric Amps Watts Frequency (Hr) 24 Fail-Safe (min) 45 Anti Condensate Heater Data (120V) 2 door 3 door 4 door 5 door Anthony ELM Amps Watts
24 APPENDIX CASE DIMENSIONS RF MODELS Top Field Mounted Condensing Unit Case L A 2 DOOR 62" (1575) 31" (787) 3 DOOR 92-7/16" (2348) 54-1/8" (1374) 4 DOOR 122-7/8" (3121) 69-5/16" (1760) 5 DOOR 153-5/16" (3894) 84-1/2" (2147) Drain Pipe (in) 1 Liquid Line (in) 3/8 Suction Line (in) 7/8
25 APPENDIX CASE DIMENSIONS RF-N MODELS Top Field Mounted Condensing Unit Case L A 2 DOOR 62" (1575) 31" (787) 3 DOOR 92-7/16" (2348) 54-1/8" (1374) 4 DOOR 122-7/8" (3121) 69-5/16" (1760) 5 DOOR 153-5/16" (3894) 84-1/2" (2147) Drain Pipe (in) 1 Liquid Line (in) 3/8 Suction Line (in) 7/8
26 APPENDIX RM/RM-N MODELS Top Field Mounted Condensing Unit Condensing Unit 2 door 3 door 4 door 5 door Condensing Unit Model FFAP-015Z-CFV-072 FFAP-015Z-CFV-072 FFAP-015Z-CFV-072 FFAP-015Z-CFV-072 Refrigerant Charge (R404a, lbs) Electrical Rating 115V/208V-1PH-60Hz : Red & Black power, white neutral, green ground MOCP (amps) MCA (amps) Notes: 1. MOCP: Maximum over-current protection, Including condensing unit and condensate removal system. 2. MCA: Minimum circuit ampacity, Including condensing unit and condensate removal system Electrical Data Fans (120V) 2 door 3 door 4 door 5 door Fans Per Case Amps Watts Lighting Data (120V) LED Lighting 2 door 3 door 4 door 5 door Anthony OptiMax Pro Amps Watts Refrigeration Data Medium Temp Evaporator ( F) 28 Discharge Air ( F) 33 Superheat Set point at Bulb ( F) 3~5 BTU/door Parallel Conventional Defrost Data Type Timed-Off Frequency (Hr) 4 Anti Condensate Heater Data (120V) 2 door 3 door 4 door 5 door Anthony ELM Amps Watts
27 APPENDIX CASE DIMENSIONS RM MODELS Top Field Mounted Condensing Unit Case L A 2 DOOR 62" (1575) 31" (787) 3 DOOR 92-7/16" (2348) 54-1/8" (1374) 4 DOOR 122-7/8" (3121) 69-5/16" (1760) 5 DOOR 153-5/16" (3894) 84-1/2" (2147) Drain Pipe (in) 1 Liquid Line (in) 3/8 Suction Line (in) 7/8
28 APPENDIX CASE DIMENSIONS RM-N MODELS Top Field Mounted Condensing Unit Case L A 2 DOOR 62" (1575) 31" (787) 3 DOOR 92-7/16" (2348) 54-1/8" (1374) 4 DOOR 122-7/8" (3121) 69-5/16" (1760) 5 DOOR 153-5/16" (3894) 84-1/2" (2147) Drain Pipe (in) 1 Liquid Line (in) 3/8 Suction Line (in) 7/8
29 WARRANTY LIMITED WARRANTY Texaking warrants to the original purchaser of every new cases to be free from defects in material and workmanship under normal use and maintenance for a period of twelve months from the date of original installation or fifteen months after shipment date from Texaking, whichever occurs first. Any parts covered by this warrant that are examined and determined by Texaking to have been defective within fourteen months from the date of original installation or seventeen months after shipment date from Texaking, whichever occurs first, shall be repaired or replaced as stated below. Texaking shall be deemed to have fully complied with its obligation under the foregoing warranties by electing either one of the following procedures, at the sole discretion of Texaking. 1. Furnishing a replacement part, freight collect, in even exchange for the returned part, freight collect. 2. Receiving the defective part, freight collect; repairing it: and returning it, freight collect WHAT IS NOT COVERED BY THIS WARRANTY 1. To any unit or any part thereof which has been subject to accident, alteration, negligence, misuse or abuse, operation on improper voltage, or which has not been operated in accordance with the Manufacturer s recommendation, or if the serial number of the unit has been altered, defaced, or removed. 2. When the unit, or any part thereof, is damaged by fire, flood, or other act of god. 3. To labor cost for replacement of parts, or for freight, shipping expenses, sales tax or upgrading. 4. When the operation is impaired due to improper installation. 5. When installation and startup forms are not properly complete or returned within two weeks after startup. 6. Outside the continental united states. This plan does not cover consequential damages. Manufacturer shall not be liable under any circumstances for any consequential damages, including loss of profit, additional labor cost, loss of refrigerant or food products, or injury to personnel or property caused by defective material or parts or for any delay in its performance hereunder due to causes beyond its control. The foregoing shall constitute the sole and exclusive remedy of any purchases and the sole and exclusive liability of manufacturer in connection with this product. All claims should include: Model number, the serial number of case, proof of purchase, date of installation and all pertinent information supporting the existence of the alleged defect. Any action or breach of these warranty provisions must be commenced within one year after the cause of action has accused. MAIL CLAIM TO: Texaking 1800 s. Great SW Pkwy., Grand Prairie, TX Tel: / Fax :
30
Ice Cream Freezer Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Ice Cream Freezer Installation and Operation Manual Please read this manual completely before
More informationCOMMERCIAL REFRIGERATOR INSTRUCTION MANUAL
COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-69R FEATURE CHART ADVERTISING PANEL FLOURESCENT SWITCH COOLING FAN FLOURESCENT LAMP EVAPORATOR INNER DRAIN PAN SHELF DOOR HANDLE GLASS DOOR CONDENSER
More informationRefrigerator Freezer Installation and Operation Manual
Speeds Up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING FREEZER Refrigerator Freezer Installation and Operation Manual Please read this manual completely before attempting
More informationGlass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Glass Door Merchandiser Installation and Operation Manual Please read this manual completely
More informationCOMMERCIAL REFRIGERATOR INSTRUCTION MANUAL
COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL Model No.: TGM-50RS TGM-72RS FEATURE CHART Before operating this unit, please read these instructions completely. HOW TO INSTALL In good ventilation. Place the
More informationMilk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Milk Coolers Installation and Operation Manual Please read this manual completely before attempting
More informationRefrigerator Freezer Installation and Operation Manual
Speeds Up the Pace of Innovation CAUTION! Refrigerator Freezer Installation and Operation Manual PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Please read this manual completely before attempting
More informationInstructIon Manual KrEs EQuIPMEnt stands
Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available
More informationBlue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers
Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 BACRF14 Blue Air reserves
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important
More informationHANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION
HANDBOOK INSTALLATION & OPERATION O3EIF MEAT CASES Table of Contents General Information... 2 Using Casters... 3 Case Dimensions... 4 Case Operations... 5 Line Up & Trim Out... 6 Piping: Refrigeration
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser
More informationInstallation & Operation Manual Ice Cream Freezers
Installation & Operation Manual Ice Cream Freezers Please read this manual completely before installing or operating this unit! BACF11 BACF15 Blue Air reserves the right to make product modification at
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Salad Bars Olive Bars Food Prep Cases Refrigerated Cases with Air-Over Displays Refrigerated Cases with Coppered Cold Well Displays Cases with Under-Counter Refrigerators
More informationHorizontal Bottle Cooler Installation and Operation Manual
Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,
More informationTurbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely
More informationTrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More informationMaxLite LED High Bay Fixtures
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT
ISLAND PRODUCE C A S E S MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK COMPONENT P054956H Rev. 7 11/06 Welcome to the ORIGIN 2 display case family. We re very pleased you joined us. This
More informationMANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier
MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250
More informationINSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112
INSTRUCTIONN MANUAL for Angle Curved Top Chest Freezer MMF9106 MMF9109 MMF9112 Please read this user s manual thoroughly before using. Keep this manual handy for further reference. Email: Service@atosausa.com
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS SPECIALTY REFRIGERATED TRANSPORT CABINETS FOR SATELLITE LOCATIONS RBQ-96 Caution: Read the instructions before using the machine. CONGRATULATIONS......and thank you for purchasing
More informationTrueClean ToteCleaner
TrueClean ToteCleaner Installation, Operation, and Maintenance Manual www.trueclean.us TrueClean Check Valve Table of Contents Introduction.... 1 About... 1 Warranty... 2 Safety... 3 Important Safety Information....
More informationCLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N
CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Model INSTRUCTION MANUAL Rev. H 2015 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS RECEIVING THE HEAT EXCHANGER...3
More informationHazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners
Product Profile Hazardgard Engineered to perform in the harshest environments Features Hazardous Location Room Air Conditioners Permanent split capacitor motor Hermetically sealed refrigeration system
More informationWMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit
January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow
More informationModel 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual
Model, 2025BN, 2025ST Staging Cabinets Instruction Manual Part No 53021 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS DANGER Machine must be properly grounded to prevent electrical shock to personnel.
More informationInstruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo
Instruction Manual Dogeroo, Super Dogeroo, and Mini Dogeroo Model No. 8102, 8103, 8108 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA Part No. 87793 SAFETY PRECAUTIONS Page 2 INSTALLATION INSTRUCTIONS
More informationOPERATION, SERVICE & PARTS MANUAL
OPERATION, SERVICE & PARTS MANUAL BROASTER 620NXP & 621 EASY BREADER Be sure ALL installers read, understand, and have access to this manual at all times. MODEL 620NXP MODEL 621 Genuine Broaster Chicken,
More information6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA
REFERENCE NOTES FOR ENGINEERING DATA "0.00" indicates that data is not available yet. Defrost heater 3-phase load is unbalanced. 3-Phase defrost heater data listed represent the maximum amps per phase.
More informationPOLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL
POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL www.polartemp.com TABLE OF CONTENT Disclaimer.......................................... Page 3 Inspection, unpacking and FMU setup.................. Page
More informationOwner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.
Owner s Manual VFH-B Series Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1 www.marsdelivers.com In line with the policy of continual product improvement, the aesthetic and dimensional
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationFor Additional Copies Please Contact:
Service & Installation Instructions Keep this booklet for Future Reference BWU SERIES BWU-BCC SERIES BWU-RB SERIES For Additional Copies Please Contact: Hillphoenix Barker Specialty Products 703 Franklin
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales BAKERY and DELI USE AND SERVICE MANUAL WARRANTY INFORMATION SPECIFICATIONS
More informationModel R060 Installation - Operation Manual
Residential Heat Pump Water Heaters Model R060 Installation - Operation Manual Important Note Read this entire manual before beginning installation Manufactured By: 6670-A Corners Industrial Court Norcross,
More informationModel AV1LED Audio-Visual LED Light Installation and Maintenance Manual
Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual 2561528A REV. A 810 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under
More informationIMPORTANT INFORMATION - PLEASE READ CAREFULLY
Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part
More informationBlade Series Heat Exchanger Operation and Installation
Blade Series Heat Exchanger Operation and Installation *IMPORTANT* For safe and satisfactory operation, please read the following instructions. Keep these instructions for future reference. Some information
More informationIMPORTANT INFORMATION - PLEASE READ CAREFULLY
Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part
More informationService Manual Models CPH2 & CPH3
Plate Heater Service Manual Models CPH2 & CPH3 888-892-2213 alluserv.com Plate Heater Service Manual Models CPH2 & CPH3 Table of Contents Introduction...................................................2
More informationRev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50
3227447 Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50 GENERAL SAFETY INFORMATION 1. PRESSURIZED DEVICES: This equipment is a pressure containing device.
More informationEnspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS
Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning
More informationIOM & Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.
IOM & Owner s Manual VFH-B Series Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1 www.marsdelivers.com In line with the MARS policy of continual product improvement, the aesthetic and dimensional
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MOBILE HEATED DISH CABINET TM HDC Series Stores, heats, and holds dishes. CONGRATULATIONS... HDC-252-I Heated model shown with flip back top opened....and thank you for purchasing
More informationMODEL NO CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL
MODEL NO. 0581 CRIMPING AND BEADING MACHINE OPERATION, PARTS & MAINTENANCE MANUAL Model: Serial #: Purchased From: Date Received: FOREWORD This manual has been prepared for the owner and operators of Roper
More informationUse and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC
Use and Care Manual Flammable Material Storage Refrigerator LRBFS06W1HC 7085 471-00 Table of Contents Table of Contents Page Please Read and Follow these Instructions... 2 California Proposition 65...
More informationInstallation, Operation, and Maintenance Manual
Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap
More informationADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT
More informationMODEL HBX-1 P/N 3G59332
MODEL HBX-1 P/N 3G59332 LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by Getz Equipment Innovators, to be free from defects in material
More informationXaact Spot. Xaact Hot Spot
Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............
More informationInstallation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.
Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator
More informationRPI Industries, Inc.
IMPORTANT: THE FOLLOWING INFORMATION SHOULD BE RETAINED FOR FUTURE REFERENCE RPI Industries, Inc. building a better case for sales CONFECTIONERY USE & SERVICE MANUAL WARRANTY INFORMATION For Models Bradford
More informationPanel Mounted Heat Exchangers by Dantherm, Inc.
Panel Mounted Heat Exchangers by Dantherm, Inc. PRODUCT INFORMATION MANUAL C0028 003 Pinnacle OM Manual Rev AB Page 1 of 14 Dantherm, Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 Tel # +1 864
More informationChanging the Light Bulb The light bulb is located behind the Temperature control. IMPORTANT: Depending on your model, the light bulb in your new refrigerator may use LED technology. If your model uses
More informationSPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax
SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts
More informationP/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)
Low Temperature Frozen Food and Ice Cream Field Installed Dual Temp Operation E P Controlled (Evaporator Pressure egulator) GENEAL Model Dual Temperature Kit Application A dual temperature kit allows one
More informationSEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL
SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL This manual is provided as a guide to installation. All installations must comply with any and all local and national electrical
More informationMaxLite LED Vapor Tight Linear Fixture
General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions
More informationService & Parts Manual
Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department
More informationMN908 No. 282C Replaces 282B LB7013
No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals
More informationAir Pump Up to 800 gallons
Air Pump Up to 800 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM #PBPAPK40W Questions, problems, missing parts? Before returning to your retailer, call our customer
More informationInstallation, Operation & Troubleshooting Instructions Pizza Table Refrigerator
R e f r i g e r a t i o n a t i t s b e s t Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator For Models: VPT- 46-NS, VPT- 65-NS, VPT- 88-NS, VPT-119-NS Manual Part No.: 50842804
More informationDUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL
DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find
More information36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included
F3610G FMI PRODUCTS, LLC 36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included FMI Products, LLC TABLE OF CONTENTS Safety Information... 3 Operating Instructions...
More informationCitation Models #2001, 2001ST, 2001BN Instruction Manual
Models #2001, 2001ST, 2001BN Instruction Manual Part No. 67861 Revised: February 2009 Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS 2 Forward This manual covers the 16oz. Popcorn Machine, model number
More informationBLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.
OWNER S MANUAL BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC. PROPER FREON USAGE The below list shows the correct Freon usage for each Sno-Block B-220-SB MP-220-SB 409-220-SB 414-08-SPB 404-08-SPB B-440-SB
More informationInstruction Manual. Double Candy Apple Cooker
Instruction Manual Double Candy Apple Cooker Model No. 4416 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2014 Gold Medal Products Co. Part No. 46841 SAFETY PRECAUTIONS DANGER Machine must be
More information36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)
36 & 48 E-Z Cone Fan Installation & Operator s Instruction Manual (Direct Drive) September 1997 MV1433C Chore-Time Warranty Chore-Time Equipment warrants each new product manufactured by it to be free
More informationMobile Hot Food Merchandiser Series. Series: MHB Operation Manual
Mobile Hot Food Merchandiser Series Series: MHB Operation Manual BKI LIMITED WARRANTY Grandview Drive Simpsonville, SC 0 USA () - Toll Free: (00) - Fax: () - WHAT IS COVERED WHO IS COVERED COVERAGE PERIOD
More information3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT
3-DECK ISLAND PRODUCE C A S E S M O D E L S : O 3 I P & O 3 I P B INSTALLATION & OPERATION HANDBOOK COMPONENT P053096D Rev. 9 11/10 Welcome to the Hill PHOENIX display case family. We re very pleased
More informationDigital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS
Digital Refrigerant System Analyzer INSTRUCTION MANUAL ENGLISH LOW START PRS T-LOW SUPERHEAT MAXMIN kpa Bar MPa R TIME P T HIGH END PRS T-HIGH SUBCOOL VAC 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com
More informationKPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationFan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.
Mode 0F Cool Dry Temp Fan Speed Timer 0n/0ff Money Saver Mode 0F hr Fan Cool Only Dry Temp Auto Swing Power Fan Speed hr Timer 0n/0ff Money Saver Fan Only Auto Swing Power For inner cleaning, contact
More informationKNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER
Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER
More informationWhynter Portable Ice Maker 33 lb capacity - White
Whynter Portable Ice Maker 33 lb capacity - White Model # : IMC-330WS INSTRUCTION MANUAL Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully
More informationZeus Extreme Owner's Manual
Owner's Manual Read and Save These Instructions Seaira Global LLC 14021 NC Highway 50 Surf City, NC 28445 910-660-0962 sales@seairaglobal.com Safety Notes WARNING: Do not adjust or alter the unit in any
More informationUSER MANUAL SAVE THESE INSTRUCTIONS
USER MANUAL Model: PM50 SAVE THESE INSTRUCTIONS CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067
More informationInstruction Manual. Cheddar Easy All-In-One Cheese Corn Shop
Instruction Manual Cheddar Easy All-In-One Cheese Corn Shop Model No. 2703-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 110028 SAFETY PRECAUTIONS
More informationThermoSaver TM Hot Gas Defrost System
PRODUCT DATA, APPLICATION & INSTALLATION GUIDE Supplement to Condensing Unit Installation and Maintenance Manual Bulletin B40-THERM-PDI-14 1069132 ThermoSaver TM Hot Gas Defrost System For use on select
More informationInstallation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.
Important Information Page 2 Installation and Operation Manual 445 Procedures Cart Installation Page 3 Description Page 5 Components Overview Page 6 Controls & Indicators Page 7 Operation Page 8 HOT Operator
More informationIAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide
Installation Manual and Owner s Guide IAQ Series Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application PCOB-09012-0--A - 9" PCO BULB PCOB-14024-0--A - 14" PCO BULB 67202220344 Revised 07-12
More informationMH70230AS MH70236AS MH70248AS
MODEL #. MH70230AS MH70236AS MH70248AS Installation, Use and Care Guide READ AND SAVE THESE INSTRUCTIONS 2014.NOV SAFETY NOTICE... 2-3 LIST OF MATERIALS... 4 INSTALLATION Ducting Calculation Sheet...
More informationHI Industrial Utility Heater HI Soleus Air International
HI1-50-03 Industrial Utility Heater HI1-50-03 2010 Soleus Air International Thank you for choosing a Soleus Air Utility Heater. This owner s manual will provide you with valuable information necessary
More informationELECTRICAL DATA: FEATURES: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET. 15 Width 7 Width
FOOD WARMING/ MERCHANDISING CABINET MODEL 323HH MODEL 323HH-7 15 Width 7 Width With the ability to hold a point-of-purchase advertisement, these sleek, compact warmers are sure to draw eye catching attention.
More informationMaxLite LED MICRO-T PANEL
` Installation Instructions General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all
More informationInstruction Manual. Super 88
Instruction Manual Super 88 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA Part No. 49555 SAFETY PRECAUTIONS DANGER Machine must be properly grounded to prevent electrical shock to personnel. Failure
More informationInstruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets
Instruction Manual 36 in. and 42 in. Popcorn Staging Cabinets Model Series 2856 and 2855 42 in. Model 2855-00-000 36 in. Model 2856-00-000 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2016 Gold
More informationQuick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010
Document No. 1800-60 Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831
More informationInline Heater for Solvent or Gas. Installation and Operation Manual
SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading
More informationGENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R
GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R OWNER S INSTRUCTIONS This manual describes how to operate and care for your appliance to get the best, most efficient, performance.
More informationHot Dog Roller Grills
Part No. 87630 Hot Dog Roller Grills Model No. 8022, 8022PE, 8023, 8023SL, 8023PE, 8024, 8024PE, 8024SL, 8025, 8025SL Cincinnati, OH 45241-4807 USA SAFETY PRECAUTIONS DANGER Machine must be properly grounded
More informationWHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel
WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel Model Number: JC-88 MODEL# : BR-125SD Instruction Manual Thank you for your purchase of this WHYNTER product. Please read this Instruction
More informationQUICK START GUIDE. Modular 3000 Series. 115 V / 60 Hz
Modular 3000 Series 115 V / 60 Hz WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making,
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dcn0620 Page 1 of 12 INSTALLATION INSTRUCTIONS CAUTION
More informationInstruction Manual. Nacho Cheese Dispenser and Warmer
Instruction Manual Nacho Cheese Dispenser and Warmer 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2013 Gold Medal Products Co. Part No. 36060 SAFETY PRECAUTIONS Page 2 INSTALLATION INSTRUCTIONS
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationAPPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS
APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS SCU-30 SWU-30 Napps Technology Corporation P.O. Box 3066 Longview, TX 75606-3066 Phone: (903) 758-2900 FAX:
More information