onlinecomponents.com
|
|
- Lorin Hamilton
- 6 years ago
- Views:
Transcription
1 English FF-SYZPF Post for Honeywell Safety Light Curtains Installation Instructions IMPROPER INSTALLATION Consult with US and/or European safety agencies and their requirements when designing a machine control link, interface and all control elements that affect safety. Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury Honeywell International Inc. All rights reserved EN FR26 GLO 903 Printed in France
2 Table of contents 1 PRODUCT DESCRIPTION 1 2 FF-SYZPF POST FOR HONEYWELL SAFETY LIGHT CURTAINS 2 3 FF-SYZPFM POST WITH PLAIN MIRROR 4 4 FF-SYZPF POST WITH INDIVIDUAL MIRRORS 6 5 ALIGNMENT INSTRUCTIONS Alignment and installation of FF-SYZPF posts ORDERING INFORMATION FF-SYZPF Post FF-SYZPF post for Safety Light Curtains FF-SYZPFM post with Plain Mirror FF-SYZPF post with Individual Mirrors Spare parts for FF-SYZPF post Alignment aid WARRANTY INFORMATION Warranty and Remedy Sales and Service EN FR26 GLO 903 Printed in France
3 1 - Product description The FF-SYZPF posts are designed for perimeter protection of dangerous areas when used together with the Honeywell safety light curtains. In this way, perimeter protections with different shapes can be realised cost-effectively (straight, L- shape, U-shape or 360 ) using one emitter and receiver only. Figure 1-1 U-shape perimeter protection using mirror posts and two posts for FF-SYA light curtains The FF-SYZPF posts exist in three versions. However, the same housing is used for all versions. FF-SYZPF: basic post to install a Honeywell safety light curtain emitter or receiver inside. FF-SYZPF : post with individual mirrors to be used with access detection systems. FF-SYZPFM : post with plain mirrors to be used with safety light curtains for limb detection such as finger, hand or leg. Mirrors in mirror posts are pre-mounted and pre-aligned in our factory. Broken mirrors can be easily exchanged on site. The mirror posts are available with mirrors reducing the scanning range by 10 % or 25 %. The Honeywell safety light curtains and the mirrors are mounted inside the post via a T-slot mounting system. The posts provide two T-slots on each straight panel offering the possibility to support additional sensors (i.e. muting sensors). Additional stacking beacons (incl. i.e. a muting lamp) can be easily installed on the plastic top plate of the post. There is a cable exit hole on the base plate for the cable of the light curtain and the cable supplying the stacking beacon. FSYZ3 POST DAMAGE BY FORKLIFT TRUCKS Install additional mechanical protection around the FF-SYZPF posts to avoid damage by forklift trucks. Failure to comply with these instructions may result in product damage EN FR26 GLO 903 Printed in France 1
4 2 - FF-SYZPF Post for Honeywell Safety Light Curtains The installation of the Honeywell safety light curtains is to be done via a T-slot mounting system using the recommended brackets (see Table 1 in Chapter 2) and eight T-shape mounting bolts (delivered with the FF-SYZPF posts). The light curtains can be mounted in two different positions inside the post. The following safety light curtain models can be installed inside the FF-SYZPF post, offering additional protection to the safety light curtain. Use of straight connectors is necessary when installing the safety light curtain on the FF-SYZPF fixed floor mounting post (See product datasheet). Table 1 FF-SY 14/30/50 or 60 series (Finger/hand /arm detection) Yellow RAL 1021 models FF-SY 234 Series (body detection) Yellow RAL 1021 models FF-SY 14/30/50 or 60 series (Finger/hand /arm detection) anodized gold colour models FF-SY to 096 FF-SY 02 to 04 FF-SY to 096 FF-SYZPF FF-SY to 096 FF-SY to 096 FF-SY 02 to 04 FF-SY to 096 FF-SY to 096 FF-SY 02 to 04 Recommended FF-SYZ straight FF-SYZ straight FF-SYZ bracket kits brackets (delivered with the brackets (delivered with the (delivered with the safety safety light curtain) safety light curtain) light curtain) Front cover Not Available FF-SYZ (2-beam) Not Available FF-SYZ (3-beam) FF-SYZ (4-beam) Mounting top view Straight bracket M4-T shape mounting bolt M4-T shape mounting bolt FF-SG18/30 series / FF-SLG18/30 series (Finger & hand detection) FF-SLG234 series (body detection) FF-SG18031 to FF-SG30031 to 109 FF-SLG02 to 04 FF-SYZPF FF-SLG18031 to FF-SLG30031 to 109 Recommended bracket kits FF-SGZ (to be ordered separately) FF-SLGZ (to be ordered separately) Front cover Not Available FF-SYZ (2-beam) FF-SYZ (3-beam) FF-SYZ (4-beam) Mounting top view FSYZ2 FF-SY 234 Series (body detection) anodized gold colour models FF-SY 02 to 04 FF-SYZ (delivered with the safety light curtain) FF-SYZ (2-beam) FF-SYZ (3-beam) FF-SYZ (4-beam) FSYZ1 FF-SG bracket kit M6 T-shape mounting bolt M5 T-shape bolt FF-SLGZ bracket M6 bolt Note: the light curtain is not included when ordering the FF-SYZPF post. FSYZPF_a FSYZPF_b EN FR26 GLO 903 Printed in France
5 Figure 2-1 Dimensions of FF-SYZPF Post for FF-SYA Light curtains (mm/in) 132 / / 5.20 R 6,5 / / / / / 0.75 Ø 64 / / 0.47 ø M10 / 0.39 R 103 / 4.04 R 6,5 / 0.26 R 6,5 / / / / ,6 / / ,2 / / ,2 / / / ,6 / 0.57 FSYA / 6.89 FSYA EN FR26 GLO 903 Printed in France 3
6 3 - FF-SYZPFM Post with Plain Mirror The FF-SYZPFM post with plain mirrors is designed to be used with light curtains for point-of-operation protection (finger, hand or leg detection). Figure 3-2 Dimensions of post (mm/in) 177 / 6.97 Figure 3-3 Dimensions of plain mirror (mm/in) 33 / / / / / / / / / Plain mirror 15 / / / / 4.17 FSYZPF / ø7 / / / / 0.24 FSYZPF97 64 / / 2.52 R 6,5 / 0.26 R 102,5 / / 0.75 R 6,5 / 0.26 ø 12 / 0.47 ø M10 / / / / / / 2.60 R 6,5 / / 6.89 FSYZ EN FR26 GLO 903 Printed in France
7 The FF-SYZPFM post is available with two different deflection mirrors (10% or 25% reduction of scanning distance) and is compatible with the following light curtains: Part Listings Description Suitable light curtain Weight (kg/lbs) FF-SYZPFM01 Floorstanding post with 1 plain mirror (10 % of loss) Point of operation: FF-SY 032 to 096 FF-SYZPFM11 Floorstanding post with 1 plain mirror (25 % of loss) FF-SG 031 to 109 FF-SLG 031 to 109 Access detection: FF-SY 02 to 04 FF-SLG02 to 04 11,1 / 24.4 Scanning ranges with FF-SYZPFM01 post with plain mirror (10% loss per mirror) Without any mirror With 1 mirror With 2 mirrors With 3 mirrors Meters Feet Meters Feet Meters Feet Meters Feet FF-SY 14 6, , ,9 16 4, FF-SY 30/50/60 20, , , , FF-SY 02 to 04 80, , , , FF-SG18/30 3, , , ,6 8.4 FF-SLG18/30 4, , , ,9 9.6 FF-SLG02 to 04 45, ,5 132,9 36, , Scanning ranges with FF-SYZPFM11 post with plain mirror (25% loss per mirror) Without any mirror With 1 mirror With 2 mirrors With 3 mirrors Meters Feet Meters Feet Meters Feet Meters Feet FF-SY 14 6, , , ,5 8,4 FF-SY 30/60/50 20, , ,3 37 8, FF-SY 02 to 04 80, , , , FF-SG18/30 3, , ,0 6,5 1,5 4.9 FF-SLG18/30 4, , ,3 7,4 1,7 5.6 FF-SLG02 to 04 45, ,8 110,8 25,3 83,1 19, EN FR26 GLO 903 Printed in France 5
8 4 - FF-SYZPF Post with Individual Mirrors The FF-SYZPF posts with individual mirrors are designed to be used together with access detection systems. Posts with 2, 3 or 4 mirrors with 10% or 25% of scanning range reduction are available. BEAM HEIGHTS Individual mirrors are pre-mounted and pre-aligned at beam heights per EN 999 in our factory. If different standards are applicable in your country, the height of the individual mirrors can be modified using a T-slot mounting system. The front cover would need to be removed if beam heights are different from those specified by EN 999. Figure 4-1 Dimensions of post D 100 / 3.94 C 122 / 4.81 B A 177 / / 8.08 Individual mirror 1300 / / / / / / / / / 2.72 Figure 4-2 Dimensions of individual mirror 15 / / 120 / / / / 2.52 Front cover FSYA / / 2.9 ø 7 / / 0.24 FSYA101 R 6,5 / 0.26 R 102,5 / / 0.75 R 6,5 / 0.26 ø 12 / 0.47 ø M10 / / / / / / 2.60 R 6,5 / / 6.89 FSYA EN FR26 GLO 903 Printed in France
9 Part Listings FF-SYZPF 2 FF-SYZPF12 FF-SYZPF 3 FF-SYZPF13 FF-SYZPF 4 FF-SYZPF14 Suitable multibeam system FF-SY FF-SLG02500 FF-SY FF-SLG03400 FF-SY FF-SLG04300 Beam heights above the reference plane per EN 999 mm ( A / B / C/ D) in (A / B / C/ D) Weight (kg/lbs) 400 / / ,7 / / 700 / / / / / 600 / 900 / / / / ,2 / 22.5 Scanning ranges with FF-SYZPF0 post with plain mirror (10% loss per mirror) Without any mirror With 1 mirror With 2 mirrors With 3 mirrors Meters Feet Meters Feet Meters Feet Meters Feet FF-SY 02 to 04 80, , , , FF-SLG02 to 04 45, , , , Scanning ranges with FF-SYZPFM1 post with plain mirror (25% loss per mirror) Without any mirror With 1 mirror With 2 mirrors With 3 mirrors Meters Feet Meters Feet Meters Feet Meters Feet FF-SY 02 to 04 80, , , ,8 110,8 FF-SLG02 to 04 45, , , , EN FR26 GLO 903 Printed in France 7
10 5 - Alignment Instructions This chapter contains information about installing and aligning the FF-SYZPF posts using a FF-SY safety light curtain. Proceed similarly with a FF-SLG access detection system using the FF-SXZLAT laser alignment tool. The use of the FF-SPZLASER laser pen with its FF-SYZ adapter for FF-SYA light curtains is recommended for an easy and fast alignment of light curtain posts and mirror posts, especially if the scanning distance is greater than 10 meters/324 feet. The laser adapter is designed to be easily clipped on the housing of the FF-SYA without any additional electrical connections. However, alignment without the laser pen alignment aid is also possible. Figure 5-1 FF-SYZ laser pen adapter and FF-SPZLASER laser pen for FF-SYA Series 5.1 Alignment and installation of FF-SYZPF posts Kitlaserflash.jpg Figure 5-2 Alignment using FF-SPZLASER laser pen and the FF-SYZ laser pen adapter for FF-SYA The following instructions explain how to align and install the FF-SYZPF posts with the FF-SYA emitter/receiver and the FF-SYZPF post(s) with mirrors in perimeter guarding applications. Alignment.jpg FSYZ4 Figure 5-3 U-shape perimeter protection using two mirror posts and two posts for FF-SYA light curtains EN FR26 GLO 903 Printed in France
11 1. Choose the correct location for the FF-SYZPF posts according to the calculated safety distance to the danger zone. IMPROPER INSTALLATION OF FF-SYA SERIES LIGHT CURTAIN Install FF-SYA Light Curtains in accordance with the safety distances following the applicable local safety regulations (OSHA, ANSI, European standards). See also the Installation Manual of the FF-SYA series. Allow entry into protected area by interruption of sensing field or other safeguarding device only. Failure to comply with these instructions could result in death or serious injury. 2. Install the barriers inside the FF-SYZPF post using the standard mounting brackets of the FF-SYA. Screw slightly to allow vertical adjustments of the barrier. Supply the emitter and the receiver with the correct power. 3. Prealign the FF-SYZPF posts roughly using one of the following methods: 1 st method: Draw a line on the ground to visualise the infrared beam path between the posts. Place the centre of each gauge on each end of this line and adjust the orientation of the gauge representing the column base plates according to this line. Figure 5-4 Positioning of the post using a straight line FSYZ7 Figure 5-5 Drilling gauge Cable exit slot Swivel hole 2 nd method: Make a visual alignment of the beam path using the image of the mirror(s): Example: U-shape perimeter guarding application (one post each for receiver and emitter, two mirror posts): Adjust the four posts until the image of the next post can be seen in the mirror of the previous post. Fixing hole Adjustment screw FSYZ4 FSYZ6 Visualcontrol.jpg Figure 5-6 U-shape perimeter protection using two mirror posts and two posts for FF-SYA light curtains Figure 5-7 Pre-alignment of posts using visual control EN FR26 GLO 903 Printed in France 9
12 4. Drill the ø 12 mm hole indicated on the centre of each gauge and install the swivel (included on delivery of posts) for each column. Drill the 3 fixing holes (ø12 mm/0.47 in) at each corner of the base plate. Place each post on its swivel and roughly adjust their orientation. 5. Each post is delivered with 3 wedges and M10 screws that are used to adjust the columns vertically. Place these wedges beyond the M10 adjustment screws. 6. Install fixing screws (not included on delivery of posts) and screw slightly. 7. Use the spirit level located at the bottom of each post to adjust each column precisely to the vertical. After the adjustment, all posts must be parallel to each other. M 10 adjustment screw Adjusting wedge Figure 5-8 Adjusting wedges Adjwedge.jpg Figure 5-9 Integrated spirit level Spirit level 8. After adjusting the columns vertically, make the optical alignment of the safety light curtains as well as the mirror posts. The laser alignment kit should be used to ease these adjustments. 9. Clip the laser adapter above an optical lens of the receiver that will be used as reference point (i.e. the first lens from the top). Tighten the screw of the laser adapter. Switch on the laser pen and slide it inside the tube. EYE EXPOSURE TO LASER LIGHT Avoid direct eye exposure to the laserlight of the FF-SPZLASER laser pen. It complies with laser Class IIa per the European standard EN and US standard US 21 CFR Failure to comply with these instructions could result in eye injury. Spirit level.jpg LASER PEN DAMAGE Ensure that the laser pen inside the mechanical adapter is well blocked, to avoid it falling down. Failure to comply with these instructions may result in product damage EN FR26 GLO 903 Printed in France
13 Figure 5-10 Alignment using FF-SPZLASER laser pen and the FF-SYZ laser pen adapter for FF-SYA 10. Adjust the receiver post in relation to the first mirror post by pivoting horizontally and vertically. The laser spot must hit the middle of the mirror. Note: visualise the red spot in the mirror by using a blank sheet as a target. Spot of laser pen Blank sheet Figure 5-11 Visualisation of the laser spot using a blank sheet Laserspot.jpg Laserpenadapter.jpg 11. Pivot the first mirror post in order to visualise the red spot in the next mirror post etc. BEAM HEIGHTS Individual mirrors are pre-mounted and pre-aligned at beam heights per EN 999 in our factory. If different standards are applicable in your country, the height of the individual mirrors can be modified using a T-slot mounting system. The front cover would need to be removed if beam heights are different from those specified by EN EN FR26 GLO 903 Printed in France 11
14 X Figure 5-12 Position and alignment of the mirrors do not need to be changed if the beam heights per EN 999 standard are applicable in your country. 12. Adjust the last mirror post and the emitter post in such a way that the red laserspot appears approximately in the area (± 50 mm/1.97 in) of the reference lens of the emitter (i.e. the first lens from the top). Spot of laser pen X Mirrorpost.jpg Laserpenspot;jpg Figure 5-13 Position of laser pen spot at perfect post alignment EN FR26 GLO 903 Printed in France
15 13. Repeat steps 7 to 10 in the opposite way with the laser adapter clipped on the emitter. 14. Screw all the M4 screws of the emitter s and the receiver s mounting brackets tight. Fix the mirror posts on the ground whilst checking the optical alignment (mounting screws are not included on delivery). 15. Check the optical alignment of the emitter and the receiver using the yellow alignment LED and the output status LED (red and green LED) on the receiver (for further information, refer to the Installation Manual of the FF-SYA Series ). Figure 5-14 LED indicator status (receiver of FF-SYA light curtain) after optimal alignment Output status LED (green): Lit on. Alignment LED (yellow): Lit off. Led.jpg EN FR26 GLO 903 Printed in France 13
16 6 - Ordering Information 6.1 FF-SYZPF Post FF-SYZPF post for Safety Light Curtains Part Listings FF-SYZPF Description Post for the installation of the following safety curtains: (The light curtain is not included when ordering the FF-SYZPF listing) FF-SYZPFM post with Plain Mirror FSYZ12 Part Listings FF-SYZPM01 FF-SYZPM FF-SYZPF post with Individual Mirrors Description Floorstanding post with 1 plain mirror (10% of loss) Floorstanding post with 1 plain mirror (25% of loss) Part Listings (*) Description FF-SYZPF02 Floorstanding post with 2 individual mirrors for use with a 2-beam FF-SYZPF12 system FF-SYZPF03 Floorstanding post with 3 individual mirrors for use with a 3-beam FF-SYZPF13 system FF-SYZPF04 Floorstanding post with 4 individual mirrors for use with a 4-beam FF-SYZPF14 system (*) FF-SYZPF0 : 10% loss per mirror FF-SYZPF1 : 25% loss per mirror FSYZ EN FR26 GLO 903 Printed in France
17 6.1.4 Spare parts for FF-SYZPF post Part Listings Description FF-SYZ Top plate for FF-SYZPF post FF-SYZ Front Cover for FF-SYZPF post, 2 beams FF-SYZ Front Cover for FF-SYZPF post, 3 beams FF-SYZ Front Cover for FF-SYZPF post, 4 beams FF-SYZ Individual mirror for FF-SYZPF0, 10% FF-SYZ Individual mirror for FF-SYZPF1, 25% FF-SYZ Plain mirror for FF-SYZPFM01, 10% FF-SYZ Plain mirror for FF-SYZPFM11, 25% FF-SYZ M6 T-Bolt mounting kit 6.2 Alignment aid Part Listings Description FF-SPZLASER Laser pen (to be used with the FF-SY light curtains). FF-SYZ Mechanical adapter for FF-SPZLASER laser pen and FF-SY light curtains FSYZ8 FF-SXZLAT Laser alignment tool for FF-SLG02 to 04 access detection systems. Pointeur.jpg FSYZ EN FR26 GLO 903 Printed in France 15
18 7 - Warranty Information 7.1 Warranty and Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during that period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is the Buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. While we provide application assistance, personally, through our literature and the Honeywell website through our literature, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. 7.2 Sales and Service Honeywell serves its customers through a world-wide network of sales offices and distributors. For application assistance, current specifications, pricing or the name of the nearest distributor, contact a nearby sales office or call: TELEPHONE + 61 (0) Australia + 33 (0) France + 49 (0) Germany Spain International + 44 (0) UK USA & Canada FAX + 61 (0) Australia + 33 (0) France + 49 (0) Germany Spain + 44 (0) UK USA & Canada INTERNET info.sc@honeywell.com ISO 9001:2000 Characteristics and dimensions of equipment listed in this manual are for reference only and are subject to change without prior notice. REGISTERED MANAGEMENT SYSTEM Honeywell International Inc. All rights reserved. Certificate No. CC Honeywell 21 Chemin du Vieux Chêne Meylan Cedex, France EN FR26 GLO 903 Printed in France
Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING
Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE 1 50053338 PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices
More informationHOA6480 Series Barcode Sensor Infrared Products
HOA6480 Series Barcode Sensor Infrared Products DESCRIPTION The HOA6480 Series is a reflective barcode sensor that incorporates a VCSEL (Vertical Cavity Surface-emitting Laser) emitter and phototransistor
More informationFF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933
Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5
More informationFF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features
C US FF-ST Series Type Safety Light Curtains Approved as Type per IEC/EN 19-1/ Description The FF-ST Series is designed for hazardous point-of-operation or access detection in industrial machine safeguarding
More informationFF-SG Series. Safety light curtain Compact and low-cost unit
Safety light curtain Compact and low-cost unit FF-SG Series FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496 - parts 1 and 2 European norms for Type
More informationMuting function The muting sensors must be able to recognise the passing material (pallets, vehicles, etc.) according to the material's length and spe
Safety multibeam system for access detection with integrated muting function Compact, Smart and Full-featured FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN
More informationInstallation Instructions for the
Installation Instructions for the Particle Sensors General Information The Honeywell Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the
More informationHIH-4000 Series Humidity Sensors
HIH-4000 Series Humidity Sensors DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or
More informationInteractive Catalog Replaces Catalog Pages
Interactive Catalog Replaces Catalog Pages Honeywell has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product
More informationHOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control
Wide Gap Transmissive Sensor HOA1888 Series FEATURES Choice of phototransistor or photodarlington output Visible ambient light and dust protective filter 12 mm (0.47 in.) slot width Snap-in housing The
More informationHIH-4602-L Series Humidity Sensors
HIH-4602-L Series Humidity Sensors DESCRIPTION HIH-4602-L Series Relative Humidity (RH) sensors are designed to deliver RH sensing in a rugged, low-cost slotted TO-5 can. The laser-trimmed, thermoset polymer
More informationV-Basic Standard V15 Series
V-Basic Standard V15 Series Electromechanical Basic Switch DESCRIPTION Honeywell s V-Basic Standard V15 series is an electromechanical switch designed for enhanced reliability at a great value. This switch
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. HIH-4000 Series Humidity Sensors The HIH-4000 Series Humidity Sensors are
More informationMICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO
MICRO SWITCH Key Actuated Safety Switches GKN Series 004740 Issue 3 Datasheet FEATURES Red switch body for easy safety recognition Four different styles of stainless steel actuator keys Three conduits
More informationSVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!
FEATURES Scan Types: Retroreflective, Polarized Retroreflective, Diffuse, Thru-Scan, and Convergent Beam Self-diagnostic output with connector versions* Smart Distributed System version Highly visible
More informationType 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r
Type 2 safety light curtain FF-SLD Series FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 61496-parts 1 and 2 European Norms 30 mm resolution for hand detection
More informationHIH-5030/5031 Series Low Voltage Humidity Sensors
Low Voltage Humidity Sensors DESCRIPTION The HIH-5030/5031 Series Low Voltage Humidity Sensors operate down to 2.7 V, often ideal in battery-powered systems where the supply is a nominal 3 V. The HIH 5030/5031
More informationIntrinsically Safe Transmitters, Option Code 2n
Installation Manual for Intrinsically Safe Transmitters, Option Code 2n ATEX PERSONAL INJURY WARNING DO NOT USE these products as safety or emergency stop devices or in any other application where failure
More informationGeneral Purpose Industrial VRS Magnetic Speed Sensors
General Purpose Industrial VRS Magnetic Speed Sensors DESCRIPTION General Purpose VRS sensors are designed for use in applications with medium to high speeds or in electrically noisy environments with
More informationMICRO SWITCH NT Series
Flat Base Toggle Switch DESCRIPTION Honeywell MICRO SWITCH NT Series toggle switches meet the need for a rugged, cost-effective toggle switch. Quality construction features include a seal between the toggle
More informationNon-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION
Sensing and Internet of Things Non-Contact Switches FF6 Series DESCRIPTION Honeywell FF6 Series are magnetically actuated noncontact safety limit switches for use in machine guarding applications, designed
More informationCONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e
PDFINFO p a g e - 0 2 7 Turbidity Sensors Wash Process Sensors APMS-10G Series ORDER GUIDE Catalog Listings* Sensor Flow-through Included Cap Installed APMS-10GRCF Yes No APMS-10GRCF-50 Yes.5 inch OD APMS-10GRCF-18
More informationTable 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.
Installation Instructions for the SS49 Series Miniature Ratiometric Issue 6 SOLDERING INSTRUCTIONS NOTICE Do not wave solder surface mount sensor ICs (catalog listings with suffixes -S or -SP). Wave soldering
More informationHPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
Particle Sensor 32322550 Issue C FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m 3 to 1,000 µg/m 3 Fully calibrated EMC: Heavy industrial level IEC61000 Response
More informationHPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
HPM Series Particle Sensor DESCRIPTION The Honeywell HPM Series Particle Sensor is a laser-based sensor which uses the light scattering method to detect and count particles in the concentration range of
More informationMICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet
MICRO SWITCH Watertight Miniature Basic Switches V15W Series Datasheet MICRO SWITCH V15W Series Watertight Miniature Basic Switches Honeywell MICRO SWITCH V15W Series miniature, sealed basic switches feature
More informationPotential Applications
HIH-4602-L HIH-4602 Series monolithic IC humidity sensor with integral precision RTD in TO-39 Features Linear voltage output vs %RH Laser-trimmed interchangeability Chemically resistant Enhanced accuracy,
More informationMiniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet
Miniature Low Pressure Flow-Through Sensors 26PC Series, Compensated/Unamplified 1 psi to 100 psi Datasheet Miniature Low Pressure Flow-Through Sensors The 26PC Series Miniature Low Pressure Flow-Through
More informationQuadrature Speed and Direction Sensors
Quadrature Speed and Direction Sensors SNG-Q Series 32304260 Issue C SNG-QPLA-000 SNG-QPRA-000 SNG-QPCA-001 SNG-QPMB-000 SNG-QPDB-000 SNG-QPDB-002 DESCRIPTION Honeywell s SNG-Q Series Quadrature Speed
More informationMICRO SWITCH NT Series
Step Base Toggle Switch DESCRIPTION Honeywell MICRO SWITCH NT Series toggle switches meet the need for a rugged, cost-effective toggle switch. Quality construction features include a seal between the toggle
More informationDESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.
DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or other device is made possible by
More informationInstallation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified
Installation Instructions for the Table. Operating Specifications Analog Digital Characteristic Unit Min. Typ. Max. Min. Typ. Max., 2, 3 Supply voltage (V supply ): 3.3 Vdc 5.0 Vdc 3.0 4.75 3.3 5.0 3.6
More informationHPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION
Particle Sensor 550 Issue D FEATURES Laser-based light scattering particle sensing Datasheet Concentration range: 0 µg/m to,000 g/m Fully calibrated EMC: Heavy industrial level IEC6000 Response time:
More informationFR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES
FR/SR Series Full Sized, Sealed Rocker Switches FR SERIES SR SERIES DESCRIPTION FR SERIES The FR Series illuminated and non-illuminated full size sealed rocker switches offer enhanced design flexibility
More informationSupply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F
Installation Instructions for the oresistive s Table 1. Electrical Specifications ( V < Vcc < 4 V, -40 C < Ta < 85 C [-40 F < Ta < 185 F] unless otherwise specified.) Characteristic Condition Min. Typ.
More informationHigh Temperature Industrial VRS Magnetic Speed Sensors
High Temperature Industrial VRS Magnetic Speed Sensors DESCRIPTION High Temperature VRS sensors are designed for use in applications where the sensor is exposed to temperatures up to 260 ºC [450 ºF]. Sealed
More informationMICRO SWITCH V15W Series Watertight Miniature Switches
MICRO SWITCH V15W Series Watertight Miniature Switches Basic Switches DESCRIPTION The MICRO SWITCH V15W is a standard-sized basic switch designed for harsh-duty, wash down areas. Rugged yet precise, the
More informationHIH-4030/31 Series Humidity Sensors
HIH-4030/31 Series Humidity Sensors DESCRIPTION Honeywell has expanded our HIH Series to include an SMD (Surface Mount Device) product line: the new HIH 4030/4031. The HIH 4030/4031 complements our existing
More informationInstallation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter
Installation Instructions for the LM Series MCU (Microcontroller Unit) Issue 3 50082092, CAUTION Be cautious when working around and connecting to the LM Series terminals, especially those other than the
More informationInstallation Instructions for the 600 Series Optical Encoders
Installation Instructions for the 600 Series Optical Encoders GENERAL INFORMATION The 600 Series Optical Encoders use non-contact technology to convert mechanical rotary motion into a digital electrical
More informationMICRO SWITCH E6/V6 Series
MICRO SWITCH E6/V6 Series Enclosed Basic Switch DESCRIPTION MICRO SWITCH BZE/DTE enclosed basic switches offer enhanced precision operation and sturdy actuation in a compact but rugged metal housing. The
More informationMICRO SWITCH BAF/DTF Series
MICRO SWITCH BAF/DTF Series High Capacity Enclosed Switches DESCRIPTION MICRO SWITCH BAF1 high capacity enclosed switches offer elastomer boot on sealed actuator verions that protects the actuating mechanism
More informationModel 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES
Tension/Compression Pancake Load Cell DESCRIPTION Designed for general purpose use in demanding applications in automotive, aerospace, and military applications. Some advantages of these tension/compression
More informationThe open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.
DESCRIPTION The SS41F/SS41G Series are small, versatile digital Hall-effect devices that are operated by the magnetic field from a permanent magnet or an electromagnet, and are designed to respond to alternating
More informationHFX Fiber Optic Component 50 Mbps, 650 nm LED
HFX7000-200 Fiber Optic Component 50 Mbps, 650 nm LED DESCRIPTION The HFX7000-200 is a 50 Mbps LED designed to meet data transmission requirements in factory or office automation. The 650 nm wavelength
More informationHIH-4010/4020/4021 Series Humidity Sensors
HIH-4010/4020/4021 Series Humidity Sensors DESCRIPTION The HIH-40104020/4021 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input
More information19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control
FEATURES Low cost Rugged, isolated stainless steel package Small size Reliable semiconductor technology Calibrated and temperature compensated Absolute and gage pressures Vacuum compatible, isolated sensors
More informationDESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.
DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or other device is made possible by
More informationMICRO SWITCH GSX Series
MICRO SWITCH GSX Series Explosion-Proof Safety Switch DESCRIPTION Honeywell Sensing and Control MICRO SWITCH GSX Series Explosion-Proof Safety Switches combines the worldclass MICRO SWITCH global safety
More informationGMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION
GMS-10 RVS Series Oxygen Sensors Accurate oxygen measurement DESCRIPTION The GMS-10 is a high-accuracy oxygen sensor suitable for many applications. Originally developed for boiler applications, the product
More informationWARNING MISUSE OF DOCUMENTATION
FEATURES Mass flow and differential pressure versions Bi-directional sensing capability Highly stable null and full-scale Extremely low pressure drop Compact package design Extremely low hysteresis and
More informationFF-SYB14, FF-SYB30 and FF-SYB50 Series Safety Light Curtains. FF-SYB234 Multibeam Systems for Access Detection
FF-SYB14, FF-SYB0 and FF-SYB50 Series Safety Light Curtains FF-SYB24 Multibeam Systems for Access Detection 200-2004 Honeywell International Inc. All rights reserved IMPROPER INSTALLATION Consult with
More informationMICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet
MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series DESCRIPTION The SZL-VL-S Series miniature-type limit switch is designed for use in applications where limited space is available. With IP67
More informationMiniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet
Miniature Low Pressure Sensors 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi Datasheet Miniature Low Pressure Sensors The 24PC Series Miniature Pressure Sensors are small, cost-effective devices
More informationFF-SYB Series. Type 4 Safety light curtain Compact, Universal, Smart and Full-featured 1FF-SYB
Type 4 Safety light curtain Compact, Universal, Smart and Full-featured FEATURES 1- or 2-beam floating blanking Manual or automatic restart External Device Monitoring (EDM) 2 or 4 inputs for muting s Manual
More informationInterfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range
DESCRIPTION The SS39ET/SS49E/SS59ET Series Low-cost Linear Halleffect sensors are small, versatile devices that are operated by the magnetic field from a permanent magnet or an electromagnet. The linear
More informationWireless Panel-Mount Monitor
Wireless Panel-Mount Monitor Limitless Monitor 0BDESCRIPTION The new Limitless product line combines the best of MICRO SWITCH limit switches with the latest commercial off-theshelf wireless technology.
More informationMicropower Omnipolar Digital Hall-Effect Sensor ICs
Micropower Omnipolar Digital Hall-Effect Sensor ICs DESCRIPTION The SL5 Series sensor ICs (Integrated Circuits) are small, versatile, digital Hall-effect devices operated by the magnetic field from a permanent
More informationSUNSTAR 传感与控制 The main features are: - COMPACT SIZE The cross section of 4 mm x 55 mm /.65 in x.6 in makes installation poss
Safety multibeam system for access detection Compact, Universal, Smart and Full-featured FEATURES Active Optoelectronic Protective Device compliant with the requirements of the IEC/EN 6496 - parts and
More information1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.
Aerospace-Grade Pressure Switch High Pressure Series 0B0BDESCRIPTION Honeywell s MICRO SWITCH 1HP Series pressure switches are designed for high pressure ranges (150 psi to 5000 psi) for use in aerospace
More informationMICRO SWITCH BX/BX2 Series
MICRO SWITCH BX/BX2 Series Hazardous Area Switches DESCRIPTION The MICRO SWITCH BX/BX2 Series is ideal for outdoor use or in adverse environments where a combination of explosion proof plus sealing requirements
More informationMICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet
MICRO SWITCH Sealed Subminiature Basic Switches ZD Series 004988 Issue 4 Datasheet FEATURES Subminiature package size SPDT, SPNC, or SPNO switch options Power-duty switching with silver contacts or logic-level
More informationFSS-SMT Series. Low Profile Force Sensor
FSS-SMT Series Low Profile Force Sensor DESCRIPTION Honeywell s FSS-SMT Series force sensors are designed to be one of the most reliable force sensors available as illustrated by 20 million Mean Cycles
More informationMagnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions
252M 252M- 552MT 252M-T2 252M-T3 005987 Issue 2 Datasheet FEATURE High sensitivity: 25 Gauss maximum operate point allows for extended sensing distance or a smaller magnet 3.8 Vdc to 30 Vdc supply voltage
More informationHIH-4602 A & C Series.
Humidity Sensors Line Guide Performance and reliability. Just because humidity products are typically standardized and platform-based, they can still deliver superior performance right out of the box.
More informationFEATURES AND BENEFITS
APS00B DESCRIPTION Honeywell s APS00B High Resolution Magnetic Angular Position Sensor IC (Integrated Circuit) is a miniature surface mount device for angular or rotary displacement designed for magnetic
More informationInstallation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4
Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4 569443 GENERL INFORMTION The RTY Series uses a magnetically biased, Hall-effect integrated circuit (I) to sense rotary
More informationIssue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS
MICRO SWITCH Rocker Switches TP Series DESCRIPTION Honeywell MICRO SWITCH TP rocker switches are designed for flush mount to the panel for a low profile button or above panel for a distinctive button appearance.
More informationMagnetoresistive Sensor ICs. Nanopower Series. Datasheet
Magnetoresistive Sensor ICs Nanopower Series Datasheet Magnetoresistive Sensor ICs Honeywell s Nanopower Series Magnetoresistive (MR) Sensor ICs are ultra-sensitive devices designed to accommodate a wide
More information19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors
19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors DESCRIPTION Honeywell s stainless steel 19C, 19U, and 19 Vacuum Gage Series sensors were developed for pressure applications that involve
More informationAirflow Sensors Line Guide
Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design,
More informationMICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet
MICRO SWITCH Sealed Subminiature Basic Switches ZD Series 004988 Issue 3 Datasheet FEATURES Subminiature package size SPDT, SPNC, or SPNO switch options Power-duty switching with silver contacts or logic-level
More informationSX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi
SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi DESCRIPTION The SX Series pressure sensors provide the lowest cost components for measuring pressures up to 150 psi. These sensors
More informationMICRO SWITCH GLL Series
MICRO SWITCH GLL Series Limit Switches DESCRIPTION Honeywell MICRO SWITCH GLL Series limit switches are part of the OEM set of miniature limit switches. They combine and enhance MICRO SWITCH GLS and SZL-VL
More informationOmnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT
Omnipolar Digital Hall-effect s: 005917 Issue 3 Datasheet FEATUES Simple activation from a North pole or a South pole and sensitive magnetics Low voltage 3 Vdc capability Built-in reverse polarity protection
More informationLimitless Wireless Din-Rail Receiver. WDRR Series. Datasheet
Limitless Wireless Din-Rail Receiver WDRR Series Datasheet Limitless WDRR Series Wireless Din-Rail Receiver The WDRR Series is a reliable din-rail or panel-mountable receiver that is designed to receive
More informationWireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series)
Wireless Heavy-Duty Limit Switch with Eyelet-Pull (WLS Series) Limitless Switch DESCRIPTION Honeywell is extending its Limitless WLS Series of Heavy Duty Wireless Limit Switches with an eyelet-pull operating
More informationInteractive Catalog Replaces Catalog Pages
Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes
More informationIssue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series
Installation Instructions for the Basic Amplified Board Mount Pressure GENERAL SPECIFICATIONS The ABP Series are piezoresistive silicon pressure sensors offering a ratiometric analog or digital output
More information900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs
900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs Document Number: 51-52-33-135 Effective: September 2017 Supersedes: June 2005 Summary The Remote Termination Panel (RTP) provides an easy
More informationSensor Evaluation Kit, SEK001
For Use with TruStability RSC Series and Digital Output Versions of the HSC Series and SSC Series Board Mount Pressure Sensors 32330034 Issue A Datasheet FEATURES The SEK001 has sockets to receive TruStability
More informationModel A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES
Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION The Model A-5 low range wet/wet differential pressure transducer offers a stainless steel assembly. The Model A-5 line pressure zero shift
More informationModel 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES
Wing Union/Hammer Union Pressure Sensors DESCRIPTION The Model 424 Wing Union Pressure Sensors are rugged sensors designed for use with 2002 and 2202 wing unions in demanding land-based and off-shore applications.
More informationE + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638
SAFETY SENSITIVE EDGES FEATURES Sensor based on an optoelectronic technology Meets the EN 1760-2 standard for Pressure Sensitive Protective Devices Permanent self-checking electronics designed in compliance
More informationAirflow Sensors Line Guide
Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced chip design,
More informationSensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations
TRANSPORTATION, INDUSTRIAL, MILITARY, AEROSPACE AND MEDICAL APPLICATIONS SMART Position Sensor, 100 and 180 Arc Configurations Superior Measurement. Accurate. Reliable. Thinking. SOLUTION Honeywell s SMART
More informationControllers, Indicators & Set Point Programmers
Controllers, Indicators & Set Point Programmers PROCESS CONTROL MADE EASY Honeywell Solutions for Indicators and Controls Honeywell Controllers DC 1010 DC 1020 UDC 100 UDC 700 Honeywell supports your process
More informationSensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP
High ensitivity Latching Digital Hall-effect 32312441 ensor ICs: Issue B 360T, 360T, 360T-10K, 460, 460-T2, 460-LP Datasheet 360T 360T 360T-10K 460 460-T2 460-LP FEATURE Fastest response time in its class
More informationModel SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES
Transducer Display and Signal Conditioning Unit DESCRIPTION The SC series models are self-calibrating microprocessor-based signal conditioners. Indicators are available with several different types of
More informationModel HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS
High Line Wet/Wet Differential Pressure Transducer DESCRIPTION The High Line Wet/Wet Differential Pressure Model HL-Z is designed to accept extreme line pressures of up to 5000 psi.* This unique design
More informationFlat Line Spray Systems Kits
Instructions/Parts Flat Line Spray Systems Kits 3A03B EN Heated or non-heated fluid circulation kits for Merkur, Merkur Bellows, and NXT Dura-Flo Pumps. For professional use only. Maximum Fluid Working
More informationInstallation Instructions for the
Installation Instructions for the Basic Board Mount Pressure Sensors TBP Series, Compensated/Unamplified 60 mbar to 10 bar 6 kpa to 1 MPa 1 psi to 150 psi Issue F GENERAL INFORMATION Honeywell s Basic
More informationHigh Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP
High ensitivity Latching Digital Hall-effect ensor ICs: 360T, 360T, 360T-10K, 460, 460-T2, 460-LP 32312441 Issue C Datasheet 360T 360T 360T-10K 460 460-T2 460-LP FEATURE Fastest response time in its class
More informationGuide to Hazardous Location Approvals:
Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition
More informationAMR 4-Pin Quadrature Sensor Integrated Circuit
MR 4-Pin Quadrature Sensor Integrated Circuit 32336294 Issue D FETURES Integrated quadrature sensor IC Pole size independent operation 4-pin quadrature, open collector outputs -40 C to 150 C operating
More informationSSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi
SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi DESCRIPTION The Standard Accuracy Silicon Ceramic (SSC) Series is a piezoresistive
More informationAerospace and Defense Applications
Aerospace and Defense Applications SENSING AND CONTROL Sensor and Switch Solutions Aerospace and Defense Customers know Honeywell Sensing and Control (S&C) by two simple words: Problem solved. For more
More informationMICRO SWITCH Cable-Pull Safety Switches CPS Series Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS
MICRO SWITCH Cable-Pull Safety Switches CPS Series DESCRIPTION Honeywell s MICRO SWITCH CPS Series Cable-Pull Safety Switches provide a readily accessible emergency stop signal, a cost-effective means
More informationOriginal operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...12 m OY UK 704555 / 05 02 / 2018 Contents 1 Preliminary note...4
More informationHigh Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet
High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S Datasheet High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs The SS360NT/SS360ST/SS460S High Sensitivity
More information