Noiseless Heater Vacuum Relief Valve
|
|
- Isaac Greene
- 6 years ago
- Views:
Transcription
1 Noiseless Heater Vacuum Relief Valve -1
2 Step Type/Structure/Features Please refer to this for structure and feature of Noiseless Heater and Vacuum Relief valve. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended of uses. Confirm the additional details on the product page. Step 2 Sizing Please refer to P.-6 to 7. Step 3 Attention for usage Please check some guidelines for optimal usage of Noiseless Heater and Vacuum Relief Valve such as installation. -2
3 Purposes and Types of Noiseless Heaters Purposes of Noiseless Heaters A noiseless heater is used to reduce noise and vibration generated when steam is blown into water to produce hot water. A sound deadening effect can be expected by connecting a noiseless heater to piping simply. Types and Principles of Noiseless Heaters Sound deadening principle Steam and water are mixed and discharged from the outlet. * Noiseless heaters cannot be used as direct mixing type inline heaters. Max. warning sound temperature limit * 6 C Features Simple in structure and trouble-free. Just attach to the end of piping. MS-1 MS-2 MS-6 Steam is blown out from the nozzle and mixed with water. Steam produces hot water while drawing water around. 9 C 9 C Available in a higher temperature range than the MS-1. Lotus root shape, compact, and produces less vibration and noise. * The max. warning sound temperature limit means the upper limit temperature at which a sound deadening effect can be expected. Lotus Root Shape Noiseless Heater MS-6 It is compact size and produces less noise. Stainless steel made body offers outstanding durability. The use of hot water is indispensable in food processing, cleaning, and plating operations. Although the simplest and most efficient way to provide the hot water is by a direct heating format. Such format often results in vibration and noise caused by steam blowing into the water tank that can be greatly reduced by mounting an MS-6 noiseless heater at the end of the pipe. steam water -3
4 Why Vacuum Relief Valves are Necessary Necessity A vacuum relief valve is used to introduce air into a device or piping and, at the same time, prevent accidents attributable to a negative pressure (vacuum). What is a Vacuum? A vacuum means a specific state of space filled with a gas whose pressure is lower than the atmospheric pressure. VB-7 Vacuum Relief Valve VB-7 When it comes to setting under pressure, a vacuum relief valve is used to introduce air into a device or piping and, at the same time, prevent accidents attributable to a negative pressure (vacuum). In addition, it ensures to prevent water pulling at the time of steam stop in the meanwhile water from tank directly touched with steam and transform into hot water. VALVE CLOSE VALVE OPEN -4
5 VACUUM RELIFE VALVES & NOISELESS HEATERS Control Charts Vacuum Relief Valve ID-Charts Model Fluid Material Pressure regulating range (KPa) Maximum temperature ( C) Connection Size Feature Page VB-7 C Steam, Air -.5 to C JIS R VB--7S SUS Stainless steel made -9 Noiseless Heater ID-Charts Model Fluid Material Maximum pressure (MPa) Max.warning sound temperature limit ( C) Connection Size Feature Page MS-1 Steam CAC C JIS Rc MS-3-13 SCS MS-2 Steam CAC C JIS Rc MS-4-13 SCS F-type -11 F-type Stainless steel made S-type -12 S-type Stainless steel made -12 MS-6 Steam SUS C JIS Rc 15- Stainless steel made -13 * Please contact us about other specifications. -5
6 Sizing for Noiseless Heaters Flow Rate Chart MS-1, Nominal size MS-2, Nominal size W: Flow rate kg/h P: Steam pressure MPa MS-6 Noise Characteristic Chart MS-6 Steam pressure {.3 MPa} W: Flow rate kg/h A Nominal size 2A P: Steam pressure MPa 8 6 W: Flow rate kg/h Steam pressure {.5 MPa} Nominal size - Noise level: db (A) Temperature C Nominal size - Noise level: db (A) Temperature C 2A P: Steam pressure MPa Nominal size - The noise characteristics of the MS-6 noiseless heater depend on the size and shape of the fluid tank, and the position where the noiseless heater is installed. Use these steam noise characteristic charts for reference. The noise levels are values measured at 1 meter above the water surface. Noise level: db (A) Temperature C Nominal size - Noise level: db (A) Temperature C -6
7 Sizing for Vacuum Relief Valve Nominal Size Selection Chart 45 4 Nominal size 35 3 Flow rate kg/h A Pressure kpa * Chart of the flow rate is for reference value. -7
8 Guidelines for Piping example of a noiseless heater without check valve Solenoid valve VB-7 Vacuum relief valve Solenoid valve VB-7 Vacuum relief valve MS-6 Noiseless heater MS-6 Noiseless heater Piping example of equipment for temperature regulation with vacuum relief valve <Calculation formula> VB-7 Vacuum relief valve Unit heater Stop valve The quantity of steam required to increase the temperature of Q kg of water by B C in time A (h) is: W = B x Q 5 x A Select a nominal size by applying the calculated quantity of steam W and the steam pressure P to the flow rate chart for nominal size selection. (Note) Use the flow rate chart for nominal size selection for reference. Stop valve Strainer Float trap Sight glass <Calculation example> When increasing the temperature of kg of water from 2 C to 6 C in an hour with.5 MPa steam (6 2) x W = = 56 (kg/h) 5 x 1 When an MS-2 silencer is used By applying the pressure of.5 MPa and the steam quantity of 56 kg/h to the flow rate chart for MS-2 nominal size selection, the nominal size of the MS-2 should be. -8
9 Vacuum Relief Valve VB-7,7S (VB-7S) Features 1. Protects devices and piping by adjusting vacuum and preventing accidents resulting from vacuum pressure. 2. Special valve structure ensures stable performance without chattering and hunting. 3. Compact, lightweight and easy to handle. 4. Made of corrosion resistant material. Specification Model Application Working pressure Pressure regulating range Maximum temperature Body Material Valve Valve seat Connection Dimensions (mm) and Weights (kg) Nominal size 2A VB-7 VB-7S Steam, Air 1. MPa Spring A.5 to 21 kpa (Standard set pressure: 4 kpa) Spring B 21 to 48 kpa (Standard set pressure: 21 kpa) Spring C 48 to 81 kpa (Standard set pressure: 48 kpa) 2 C Brass Stainless steel Cast bronze Cast stainless steel Brass Stainless steel JIS R screwed d H A R 1/2 R 3/4 R 1 R 1-1/4 R 1-1/2 R Weight
10 VB-7, 7S Example Piping Diagram <Piping example of temperature regulating equipment> <Piping example of noiseless heater without check valve> Stop valve VB-7 Vacuum relief valve VB-7 Vacuum relief valve Stop valve Unit heater Sight glass MS-2 Noiseless heater Discharge Strainer Float trap Tank Nominal Size Selection Chart Flow rate kg/h Nominal size 2A Pressure kpa * Chart of the flow rate is for reference value. -1
11 Noiseless Heater MS-1,MS-3 (MS-3) Features 1. Noise can be reduced by attaching to the end of the piping. 2. Trouble-free simple structure. 3. Made of corrosion-free stainless steel (MS-3-13). Specification Model Application Working pressure Max. warning sound temperature limit Material Connection Dimensions (mm) and Weights (kg) Nominal size 2A Steam d Rc 1/2 Rc 3/4 Rc 1 Rc 1-1/4 Rc 1-1/2 Rc 2 L L MS-1 MS-3-13 Steam.5-.7 MPa 6 C Cast bronze Cast stainless steel JIS Rc screwed L 2 H Weight Nominal Size Selection Chart W: Flow rate kg/h Nominal size 2A Water P: Steam pressure MPa * Chart of the flow rate is for reference value
12 Noiseless Heater MS-2,MS-4 (MS-4) Features 1. Noise can be reduced by attaching to the end of the piping. 2. Trouble-free simple structure. 3. Available in a higher temperature range than the MS-1 and MS Made of corrosion-free stainless steel (MS-4-13). Specification Model Application Working pressure Max. warning sound temperature limit Material Connection Dimensions (mm) and Weights (kg) Nominal size 2A d Rc 1/2 Rc 3/4 Rc 1 Rc 1-1/4 Rc 1-1/2 Rc 2 C MS-2 MS-4-13 Steam.1-.7 MPa 9 C Cast bronze Cast stainless steel JIS Rc screwed B Weight.5 (.4) (1.2) 3.2 (2.2) 4.2 (3.9) 7. (5.4) * Nozzle shape, hole diameter and the number of holes are different depending on the nominal diameter. * The above values in parentheses are the weights of MS Steam Nominal Size Selection Chart W: Flow rate kg/h Nominal size 2A P: Steam pressure MPa * Chart of the flow rate is for reference value
13 Noiseless Heater MS-6 Features 1. Stainless steel made body offers outstanding durability. 2. Easy to connect to piping, inexpensive. 3. Easy to maintain. Specification Application Working pressure Max. warning sound temperature limit Material Connection Dimensions (mm) and Weights (kg) Nominal size 2A Steam.5-.7 MPa 9 C Stainless steel JIS Rc screwed d L D Rc 1/2 Rc 3/4 Rc 1 Rc 1-1/4 Rc 1-1/2 Rc Weight Steam -13
14 MS-6 Nominal Size Selection Chart 1 9 Nominal size 8 W: Flow rate kg/h A P: Steam pressure MPa * Chart of the flow rate is for reference value. Noise Characteristic Chart Steam pressure {.3 MPa} Nominal size - Nominal size - Noise level: db (A) Noise level: db (A) Temperature C Temperature C Steam pressure {.5 MPa} Nominal size - Nominal size - Noise level: db (A) Noise level: db (A) Temperature C Temperature C The steam noise characteristic chart depends on the size or shape of the liquid tank, the location of the noiseless heater, and other factors. Use it for reference. The noise level was measured at a point 1 meter above the water surface
15 Annex CAUTION Please refer to the manual attached to the product for procedures for installation and operation. MS-1 to 6 Noiseless Heater Annex Caution for installation Noiseless Heater To obtain a result as planned, fully utilize the nominal size selection chart. There are various methods in attachment. Consider intake position and discharge position with the tank size, etc (see piping example). Use noiseless heater with sinking under water inside tank. If used as piping example-b, makelength as short as possible. Install noiseless heater 3 mm or more away from wall or bottom of tank. To prevent back flow phenomenon when steam is stopped, installation of VB-7 vacuum relief valve is recommended. Piping example Noiseless Heater For MS-1, 3 For MS-2,4 For MS
16 Annex CAUTION Please refer to the manual attached to the product for procedures for installation and operation. Troubleshooting Vacuum Relief Valve Trouble Cause Remedy Fluid leakage from cap can be checked visually or by sound. The product starts to work at pressure lower than set pressure. The product does not work even at set pressure. Foreign substances are stuck on the contact Repair at our factory is needed. face between valve and valve seat. Contact face between valve and valve seat is Product disassembly and parts replacement are needed. damaged. Repair at our factory is needed. Malfunction occurs due to vibration at the piping The product cannot be used for devices or equipments where the product is installed. where large vibration occurs. Difference between set pressure and normal Difference between set pressure and normal pressure pressure of the product is small. has to be increased. To regulate set pressure again, regulation at our factory is needed. Sliding part of valve and valve seat does not Disassembly and cleaning of the product is needed. move smoothly. Repair at our factory is needed. Product specification is different with usage Check the set pressure engraved on the plate of the condition. product. If usage condition is different, replace the product. Pressure gauge is out of order. Calibrate or replace the pressure gauge. Set pressure of the product is distorted. Repair at our factory is needed. Product specification is different with usage Check the set pressure engraved on the plate of the condition. product. If usage condition is different, replace the product. Pressure gauge is out of order. Calibrate or replace the pressure gauge. Set pressure of the product is distorted. Repair at our factory is needed. Sliding part of valve and valve seat does not Disassembly and cleaning of the product is needed. move smoothly. Repair at our factory is needed. -
13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationRadiator Trap Radiator Valve
Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products
More informationDisc Type Steam Trap TSD-42
Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat
More informationPamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationPamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationPamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet A2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationINSTALLATION, OPERATION
OM No. E-ES8N-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ES8N MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku Osaka
More informationComplex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator VN Series
EXTERNAL GENERATOR CONTROLLER PAD ACCESSORIES Complex Vacuum Generator realizing Stable and High-Speed Response Vacuum Generator Series 282 Suitable for semiconductor industry such as IC chip loader or
More informationVRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT
Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related
More informationPressure Switches Precautions 1 Be sure to read this before handling.
Pressure Switches Precautions 1 Design / Selection 1. Confirm the specifications. Products represented in this catalog are designed ony for use in compressed air systems (including vacuum). Do not operate
More informationMembrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification
Membrane Air Dryer Series IDG Dew point indicator Dew point indicator visually confirms air drying (Except IDG) (Optional on IDG3, IDG5, IDG3H, IDG5H) Compact Lightweight Space-saving Type with fitting
More information.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.
Issued 2006/08/01 Section 15181 Hydronic Specialties Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal.3 Section 01780
More informationSteam Trap. Assist Trap Radiator Trap Radiator Valve
Assist Trap Raiator Trap Raiator Valve /Assist Trap Selection 0.3 0.5 0.7 1.0 150 160 170 220 231 232 231 233 TF-1 TFA-2000 TF-2 TB-5 1.0 2.0 4.2 183 220 425 228 228 229 229 227 227 226 TSD-7 TSD-7F TS-7
More informationSteam Condensing Heat Exchanger SR-3 / SR-8
172-65207M-03 (SR-3/SR-8) 23 April 2014 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Steam Condensing Heat Exchanger SR-3 / SR-8 Copyright 2014 by TLV CO.,
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationOPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"
OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER Electric Heater Company Base Model "BWXP" HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationC. B. Trading Corporation
+91-8048737256 C. B. Trading Corporation http://www.cbtc.in/ C. B. Trading Corporation is an eminent distributor and trader of a wide range of s, Pipe Fittings, Forged Carbon Steel and Water & Steam Flow
More informationMini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.
Armstrong Mini Pump Bulletin AFH-223 The Armstrong mini pump trap is the smallest non-electric solution that can move condensate or other liuids from lower to higher points and from lower to higher pressures.
More informationInstallation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier
OM001 Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier These operating and maintenance instructions are for standard semi-storage calorifiers (vessels fitted with
More informationMaintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently
Part One How to Maintain a TOWER of POWER Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently BY GLENN A. BABCOCK The cooling tower is often the forgotten component
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
Membrane Air Dryer RoS New Possible to easily supply dry air using the hollow fiber membrane! Non-fluorocarbon Compatible with low dew point ( 6C) No vibration or heat discharge Purge air flow rate (L/min
More informationINSTALLATION, OPERATION
OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku
More informationReducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Reducing Valve Direct Mount Type with Pressure Gauge 232 Direct Mount Type (Compact size) Pressure Gauge is selectable. Display
More informationAir. Pressure. Motion. nnnnnnnn
Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page
More informationVacuum Saving Valve. ZP2V Series. With One-touch fitting type available!
Vacuum Saving Valve Series Can restrict the reduction of vacuum pressure even when there is no workpiece. When multiple vacuum pads are operated by one vacuum generator, and some of them are not holding
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationSeries 300 VTB. Installation Instructions
Series 300 VTB Installation Instructions Sizes 7 12 16 20 30 HP #2 Fuel Oil Gas (500 to 2500 BTU) Gas Light Oil Combination High Pressure Steam Sizes 7 thru 16 HP (125 PSI) Sizes 20 and 30 HP (150 PSI)
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE
Page 1 of 12 1. (Refer to Figures 1-7.) Viking supervised Single-Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system piping
More informationA. This Section includes the following domestic water piping specialties:
SECTION 221119 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationOPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F
OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationTel: Fax: Website:
Vacuum Dehydration Oil Purification System(Oil Purifier) The water and particles contamination in lubrication, hydraulic and dielectric oils badly affect the oils performance and threaten system reliability.
More informationFilter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Redcing Valve with Built-in Filter Filter Regulator 238 Filter for Drain and Dust (Filtering Accuracy: 5µm) Plastic made Bowl
More informationPUGMILL/MIXER. Instruction Manual NVS-07
92895B PUGMILL/MIXER Instruction Manual NVS-07 Attention After carefully reading this manual, be sure to store it in a safe and convenient place for easy reference. Before using this unit, please read
More informationPure Performance For Steam Mains and Tracers
Pamphlet M2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Redefining the Disc Trap Concept Life Cycle Cost for steam trap management includes
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationInverted Bucket Steam Traps
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,
More informationCost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.
Membrane Air Dryer A/ RoS Possible to easily supply dry air using the hollow fiber membrane! AT Non-fluorocarbon Compatible with low dew point ( 6 C) No vibration or heat discharge Purge air flow rate
More informationTECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.
September 8, 2000 Dry 132 a 1. PRODUCT NAME High Pressure Dry System Manufactured 2000-2. MANUFACTURER The Viking Corporation 210 N Industrial Park Road Hastings MI 49058 U.S.A. Telephone: (616) 945-9501
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More informationVS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL
VS SERIES NH3 STEAM VAPORIZERS Revised March 1997 OPERATION MANUAL CONTENTS PAGE 1. GENERAL................................... 1 Figure 1-1 - VS Series Vaporizer......................... B How to Select
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer
INSTRUCTION MANUAL Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES SS3N SS3V / SS5N SS5V / SS5NH SS5VH Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo
More informationMultistage Ejector MODEL / Series / Product Number
Doc. no. ZL-0M00801 PRODUCT NAME Multistage Ejector MODEL / Series / Product Number ZL112 212 Series Contents Doc. no. ZL-OM00801 Safety Instructions 2 Model Indication and How to Order 10 Mounting and
More informationInstallation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50
Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationDomestic Pump Condensate Transfer Equipment
Bulletin S-944L Domestic Pump Condensate Transfer Equipment CONDENSATE RETURN UNITS BOILER FEED UNITS LOW NPSH PUMPS VACUUM HEATING UNITS INDUSTRIAL VACUUM UNITS www.domesticpump.com Condensate Return
More informationEBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL WM150 OWNERS MANUAL Page 1 of 9 INTRODUCTION Designed for a wide range of applications, the WM150 is a rugged, industrial unit, which utilizes an
More informationScrew Water Cooled Chiller SCW210
Screw Water Cooled Chiller SCW210 Nominal Cooling Capacity 185.1 to1480.8 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical
More informationMFP14 Automatic pumps. for condensate and other industrial fluids
MFP1 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationCOOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...
COOLING SYSTEM DESCRIPTION... Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... CO-5 CO-6 THERMOSTAT... CO-8 RADIATOR... CO-9 CO-2 COOLING SYSTEM - Description
More informationV48 Series 3-Way Water Regulating Valves For Cooling Tower Systems
Product/Technical Bulletin V48 Issue Date 0512 V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems Application IMPORTANT: The V48 Series Water Regulating Valve is intended to control water
More informationMEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Features, Dehumidification Principles, Order Codes 209 Specifications, Dimensions 210 Dry Air Flow Rate,
More informationModels: FM FM WARNING
Installation Stainless Steel Blowout Urinal Models: 923-8000 923-8001 923-8002FM 923-8003FM Table of Contents Overview...2 Pre-Installation Information...3 Installation Instructions...4-7 Cleaning Instructions...7
More informationValve timing. Atmospheric air
31.5-mm wide vacuum unit is designed to optimize the control of large vacuum flows. Vacuum generator and External vacuum controller are available for various needs. Three different types of vacuum generator
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationDiocese of Cleveland Facilities Services Corporation
Diocese of Cleveland Facilities Services Corporation BOILER MAINTENANCE and SERVICING SEASONAL MAINTENANCE - to be performed by trained boiler technician or boiler contractor only: 1. Disassemble the low
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationVacuum system component SELVACS
Vacuum system component SELVACS Vacuum related components CC-796A 1 Wide variations for an assortment of applications New SELVACS vacuum components respond to a wide range of applications from fine work
More informationCKD refrigerating type dryer
CKD refrigerating type dryer GT9000 Applicable air compressor: 90, 120, 1, 190, 240, 300, 380, 4, 710, 960kW Components for air preparation and pressure adjustment / main line unit / refrigerating type
More informationYARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260
SERIES 40/40D AND C250/260 Designed for a variety of high pressure and high capacity applications found in utility, industrial and marine service FEATURES Designed to fail open. Designed for superheat
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationEnvironmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.
As a specialized enterprise in making vacuum pumps, we have devoted ourselves to satisfy our customers need for high quality products. We adopt the latest designs and technology to make sure that our products
More informationINSTALLATION & MAINTENANCE MANUAL FOR QuickDraw
INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube
More informationDatasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description
FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components
More informationTECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE
Page 1 of 8 1. DESCRIPTION Viking Deluge Systems utilize a Viking Deluge Valve to control the water supply to system piping equipped with open sprinklers and/or spray nozzles. The system piping remains
More informationCost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500
embrane Air Dryer Possible to easily supply dry air using the hollow fiber membrane! Purge air flow rate (L/min [ANR]) 18 16 14 12 8 6 4 IDGA..5 1. Variations Non-fluorocarbon Energy saving IDGA Inlet
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationExternal Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series
EXTERNAL PAD ACCESSORIES External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series 37 Small in size and lightweight External Vacuum
More informationInstallation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63
Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION
More informationTroubleshooting the MPH 24FP Series Pedestal Hydrant
MAPA Products P.O. Box 129 Naples, Texas 75568 Toll Free: 877 897 2371 How the Hydrant Works: Troubleshooting the MPH 24FP Series Pedestal Hydrant The design of the hydrant assembly is based on a venturi
More informationSECTION 1D ENGINE COOLING
SECTION 1D ENGINE COOLING CAUTION: Disconnect the negative battery cable before removing or installing any electrical unit or when a tool or equipment could easily come in contact with exposed electrical
More informationOWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:
OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,
More informationKRF15A-03 KRF25A-03 KRF40A-03
OILLESS ROTARY VACUUM PUMP & BLOWER ORION DRY PUMP KRF15A-03 KRF25A-03 KRF40A-03 KRF40A-03 CAUTION This product is intended only for industrial use. Use with caution. Read this Instruction Manual and follow
More informationAir Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)
http://www.pisco.co.jp AIR PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Filter for Removing Dust and Drain in Compressed Air Air Filter 220 Filter for Drain and Dust (Filtering Accuracy: 5µm) Resin-made
More informationTotalPac 3 Firecyle III Deluge Remote controlled system
(Optional) DESCRIPTION This TOTALPAC 3 integrated fire protection system by FireFlex Systems Inc. consists of a Firecycle III system trim totally preassembled, pre-wired and factory tested. All electrical
More informationMVG. Modular Vacuum Grippers. US5
Modular Vacuum Grippers MVG www.coval.com US5 MVG COVAL s MVG Series: Customized Customized Solution COVAL s MVG series vacuum grippers correspond perfectly to the expectations of integrators and users:
More informationModel DDX Deluge Valve
Model DDX Deluge Valve Bulletin 510 Bulletin 510 Features 1. Differential type, simple, lightweight, dependable construction. 2. Simply and easily trimmed for releasing by: Manual pull stations Wet pilot
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationPure Performance For Steam Mains and Tracers
Pamphlet A2004-2 Thermodynamic Steam Traps P Series FP Series HR Series Pure Performance For Steam Mains and Tracers Are you looking for Improved Performance? Disc traps are valued for their compact size
More informationScroll Water Cooled Chiller
Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical
More informationVacuum Pump Vacuum Pump
1 COVP28-38-46-65-106 vacuum pump Oil lubricated vacuum pump COVP is a compact oil lubricated vacuum pump series, ready for connection and operation. The main electrical motor is directly connected to
More informationBK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4
More informationMODEL 7000 SUCTION UNIT
MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices
More informationMC5-G1,G3 SPARE PARTS. Temperature Controller : TEMP. CONTROLLER CODE NO. PART NAME MACHINE MODEL PRICE (THB)
SPARE PARTS Temperature Controller : TEMP. CONTROLLER 117749 TEMPERATURE CONTROLLER MR16-AN-04 (MC5-G1) MC5-G1 9,000 TEMP. CONTROLLER 118273 TEMPERATURE CONTROLLER MR16-CT-04 (MC5-G3) MC5-G3 20,000 FLOAT
More informationheating liquids PENBERTHY JET PUMP TECHNICAL DATA Section 1000 Bulletin 1400 Issued 6/87 Replaces 6/85
Section 1000 Bulletin 1400 Issued 6/87 Replaces 6/85 PENBERTHY JET PUMP TECHNICAL DATA heating liquids This technical bulleting includes general information about Penberthy Steam Jet Heaters plus specific
More informationMFP14 Automatic pumps for condensate and other industrial fluids
MFP14 Automatic pumps for condensate and other industrial fluids Effective condensate management... an essential part of any steam plant If energy requirements are to be kept to a minimum, then efficient
More informationFunne~ Jiffy J-4000 Model Steamer FEATURES INCLUDES: From the library of: Superior Sewing Machine & Supply LLC
Jiffy J-4000 Model Steamer FEATURES Built-in, easy-to-read sight gauge also indicates sediment build-up Cast aluminum housing unit for durability Corrosion-proof stainless steel boiler tank--no water lines
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More informationTrouble Shooting Guide PWA, 3-phase (D10571)
Trouble Shooting Guide PWA, 3-phase (D10571) Trouble Shooting Guide Problem Possible Cause Possible Remedy Unit does not start Unit does not cool No power to unit, breaker tripped Low voltage Loose wire
More informationPackaged Steam Fired Water Heater
MODEL ST Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters Features Reliable Packaged System Only high grade materials used in construction
More informationPRODUCT SPECIFICATION GUIDE
TM PRODUCT SPECIFICATION GUIDE CONTENTS Intro 04 SECTION 1.0 TAPWARE 05 1.1 BUBBLERS Wolfen 122 Wall Bubbler 06 Wolfen 90 Wall Bubbler 08 Wolfen Hob Bubbler 10 Wolfen Remote Button Bubbler 12 1.2 FOOT
More informationSteam Traps and Steam Specialties
Steam Traps and Steam Specialties The new shape in steam traps... Bestobell s Delta Element A sophisticated, yet simple, design that will provide years of trouble-free service with no live steam loss.
More informationTOTALPAC2 Integrated Fire Protection System
TOTALPAC2 Integrated Fire Protection System Page 1 of 8 General 1. Applicable Standards The TOTALPAC2 Surefire complies with the following standards: - NFPA-13 Sprinkler Systems; - NFPA-15 Water Spray
More informationNiles Steel Tank Hot Water Generator Installation and Operation Manual
Niles Steel Tank Hot Water Generator Installation and Operation Manual Contents: Contents 1 Hazard definitions 1 1. General Information.... 2 Availability... 3 Optional Control Packages... 5 2. Installation....
More informationACORE Filtration Co.,Ltd provides engineering,
Oil Filtration Systems For Every Demanding Application VLF Lube Oil Purifier ACORE Filtration Co.,Ltd provides engineering, manufacturing, sales of industrial oil filtration systems, we have been striving
More informationTECHNICAL DATA OBSOLETE
January 27, 2012 311a 1. DEsCrIpTIoN (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system.
More informationSilhouette. Feedwater Heater. Boiler Feedwater
Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator
More informationHollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting
http://www.pisco.co.jp PREPARATION ACTUATOR PLARAILCHAIN HARMO ROBOT PARTS Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting Fiber Dry Series 188 Hollow Fiber Membrane Filter Type
More informationPamphlet M2012 BALANCED PRESSURE THERMOSTATIC STEAM TRAPS
Pamphlet M01 BALANCED PRESSURE THERMOSTATIC STEAM TRAPS capsule element for reliability and safety. The capsule element contains a liquid whose saturation temperature is slightly lower than the saturation
More information