1 GD-500 Bead Detection System Customer Product Manual Issued 4/08 NORDSON CORPORATION DULUTH, GEORGIA USA

2 Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General information about Nordson can be found on the Internet using the following address: Address all correspondence to: Nordson Corporation Attn: Customer Service Lakefield Drive Duluth, GA Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Baitgun, Blue Box, CanWorks, Century, CF, Clean Coat, CleanSleeve, CleanSpray, ColorMax, Color-on-Demand, Control Coat, Coolwave, Cross-Cut, Dispensejet, DispenseMate, DuraBlue, DuraDrum, Durafiber, DuraPail, Dura-Screen, Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo-Coat, e.dot, EFD, ESP, e stylized, ETI, Excel 2000, Fillmaster, FlexiCoat, Flex-O-Coat, Flow Sentry, Fluidmove, FoamMelt, FoamMix, HDLV, Heli-flow, Helix, Horizon, Hot Shot, icontrol, iflow, isocoil, Isocore, Iso-Flo, itrax, Kinetix, Lean Cell, Little Squirt, LogiComm, Magnastatic, March, Maverick, MEG, Meltex, Microcoat, Micromark, MicroSet, Millennium, Mini Squirt, Mountaingate, MultiScan, Nordson, OptiMix, Package of Values, Pattern View, PermaFlo, Plasmod, Porous Coat, PowderGrid, Powderware, PRIMARC, Printplus, Prism, ProBlue, Prodigy, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, RBX, Rhino, Saturn, Scoreguard, Seal Sentry, Select Charge, Select Coat, Select Cure, Slautterback, Smart-Coat, Solder Plus, Spectrum, Speed-Coat, SureBead, Sure Clean, Sure Coat, Sure-Max, Tracking Plus, TRAK, Trends, Tribomatic, TrueBlue, Ultra, Ultrasaver, UpTime, u TAH, Vantage, Veritec, VersaBlue, Versa-Coat, Versa-Screen, Versa-Spray, Walcom, Watermark, and When you expect more. are registered trademarks of Nordson Corporation. Accubar, Advanced Plasma Systems, AeroDeck, AeroWash, AltaBlue, AquaCure, ATS, Auto-Flo, AutoScan, Best Choice, Blue Series, Bowtie, Bravura, Check Mate, ClassicBlue, Classic IX, Controlled Fiberization, Control Weave, CountourCoat, CPX, CScan, Cyclo-Kinetic, DispensLink, DropCure, Dry Cure, DuraBraid, DuraCoat, Easy Clean, EasyOn, EasyPW, Eclipse, e.dot+, Emerald, Encore, E-Nordson, Equi=Bead, FillEasy, Fill Sentry, Fluxplus, Get Green With Blue, GreenUV, G-Net, G-Site, idry, ion, Iso-Flex, itrend, Lacquer Cure, Maxima, MicroFin, MicroMax, Mikros, MiniBlue, MiniEdge, Minimeter, MonoCure, Multifil, Myritex, OptiStroke, Partnership+Plus, PatternJet, PatternPro, PCI, Pinnacle, Powder Pilot, Powercure, Precise Coat, Process Sentry, Pulse Spray, Quad Cure, RediCoat, Ready Coat, Royal Blue, Select Series, Sensomatic, Shaftshield, SheetAire, Signature, Smart, SolidBlue, Spectral, Spectronic, SpeedKing, Spray Works, Summit, Sure Brand, SureFoam, SureMix, SureSeal, SureWrap, Swirl Coat, Tempus, TinyCure, Trade Plus, ThruWave, UltraMax, Ultrasmart, Universal, ValveMate, VersaDrum, VersaPail, Vista, Web Cure, and 2 Rings (Design) are trademarks of Nordson Corporation. Designations and trademarks stated in this document may be brands that, when used by third parties for their own purposes, could lead to violation of the owners rights. All rights reserved

3 Table of Contents i Table of Contents Safety Qualified Personnel Intended Use Safety Alert Symbols Regulations and Approvals Personal Safety Fire Safety Action in the Event of a Malfunction Equipment Disposal System Overview System Components GD-500 Controller GD-500 Sensor Trigger Encoder Installation Required Equipment Unpack the GD-500 Sensor Dimensions GD-500 Controller GD-500 Folding Carton Sensor GD-500 Corrugated Sensor Mounting Guidelines Mount the GD-500 Sensor Folding Carton System Corrugated System Mount the GD-500 Controller Cable Connections

4 ii Table of Contents Setup GD-500 Controller Operator Panel Operator Panel Buttons and LEDs Operational Overview Service Menu Setup Procedures Run Mode Sensor Trigger Offset (STO) Calibration Samples Minimum Tolerance Maximum Tolerance Sensitivity Threshold Encoder Ratio Language Software Version Return to Run Mode When to Adjust Service Settings Dynamic Calibration Mode Setup Procedure Calibrate the GD-500 System from the GD-500 Controller Operator Panel Calibrate the GD-500 System from the LogiComm Touch-screen Panel Learn Pattern Setup on the LogiComm Touch-screen Panel Glue Sensor Input Set-up Excess Sensor Input Set-up Maintenance Parts List GD-500 Parts for Folding Carton Machines GD-500 Parts for Corrugated Machines

5 GD-500 Bead Detection System 1 GD-500 Bead Detection System Safety Read this section before using the equipment. This section contains recommendations and practices applicable to the safe installation, operation, and maintenance (hereafter referred to as use ) of the product described in this document (hereafter referred to as equipment ). Additional safety information, in the form of task-specific safety alert messages, appears as appropriate throughout this document. WARNING: Failure to follow the safety messages, recommendations, and hazard avoidance procedures provided in this document can result in personal injury, including death, or damage to equipment or property. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include: using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings

6 2 GD-500 Bead Detection System Safety Alert Symbols The following safety alert symbol and signal words are used throughout this document to alert the reader to personal safety hazards or to identify conditions that may result in damage to equipment or property. Comply with all safety information that follows the signal word. WARNING: Indicates a potentially hazardous situation that, if not avoided, can result in serious personal injury, including death. CAUTION: Indicates a potentially hazardous situation that, if not avoided, can result in minor or moderate personal injury. CAUTION: (Used without the safety alert symbol) Indicates a potentially hazardous situation that, if not avoided, can result in damage to equipment or property. Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. All phases of equipment installation must comply with all federal, state, and local codes. Personal Safety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing any moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment.

7 GD-500 Bead Detection System 3 If you receive even a slight electrical shock, shut down all electrical equipment immediately. Do not restart the equipment until the problem has been identified and corrected. Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. Fire Safety To avoid a fire or explosion, follow these instructions. Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until the cause has been identified and corrected. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Provide adequate ventilation to prevent dangerous concentrations of volatile materials or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits while working with flammable materials. Shut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shut off valves, and fire extinguishers are located. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: Disconnect and lock out electrical power. Close pneumatic shutoff valves and relieve pressure. Identify the reason for the malfunction and correct it before restarting the equipment. Equipment Disposal Dispose off equipment and materials used in operation and servicing according to local codes.

8 4 GD-500 Bead Detection System System Overview This manual describes the installation, connection, setup, and operation of the GD-500 controller and sensor when used with the LogiComm control system. The GD-500 sensor monitors liquid adhesive applications, such as side-seem, wheel-pot, or extrusion gluing, for too much or too little adhesive. A keypad and an LCD display allows alarm thresholds to be set in order to prevent weak bonds or squeeze-out. The sensor has an automatic calibration feature to aid in establishing accurate maximum and minimum settings. When used with the LogiComm system, defective products can be tracked through the machine and ejected or marked for later ejection. There are several configurations of GD-500 systems to target specific applications. This includes sensor versions for the Folding Carton and Corrugated machines. The controller and sensor cable are the same for all configurations, but the sensor geometry and brackets are optimized for each application. See Figure 1 for a system overview.

9 GD-500 Bead Detection System 5 Figure 1 System components 1. LogiComm control module 2. Touch-screen panel 3. GD-500 controller 4. LogiComm cable 5. Trigger 6. GD-500 sensor (folding carton version) 7. Encoder

10 6 GD-500 Bead Detection System System Components The GD-500 bead detection system requires the following components: GD-500 controller GD-500 sensor Trigger Encoder LogiComm control system (control module and touch-screen panel) GD-500 Controller The GD-500 controller is an adhesive detection unit that works in conjunction with the GD-500 sensor to detect the amount of liquid adhesive on different materials, such as paper, carton, etc. The GD-500 controller contains an operator panel that allows for programming and operation. Figure 2 GD-500 controller showing the connector panel 1. GD-500 controller 3. Connector panel 2. Operator panel

11 GD-500 Bead Detection System 7 GD-500 Sensor The GD-500 sensor measures the amount of liquid adhesive on the substrate as it passes between the sensor arms. GD-500 Sensor for Folding Carton Machines Figure 3 GD-500 sensor for folding carton machines 1. Power input/signal output connector 2. Sensor measuring points 3. Sensor arms 4. Shock absorber and mounting bolts

12 8 GD-500 Bead Detection System GD-500 Sensor for Corrugated Machines Figure 4 GD-500 sensor for corrugated machines 1. Power input/signal output connector 2. Sensor measuring points 3. Sensor arms 4. Shock absorber and mounting bolts Trigger The trigger signal is transmitted from the photocell to the GD-500 and then to the LogiComm trigger input for product tracking and for displaying the measurement result on the touch-screen panel. Encoder The GD-500 sensor uses the LogiComm encoder signal from the Encoder Repeater output on the LogiComm master bank. By default the GD-500 controller is set for a ratio of 1 pulse/mm, but other ratios can be set through the GD-500 controller menus.

13 GD-500 Bead Detection System 9 Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. This section describes the following instructions: Mount the GD-500 sensor and controller Connect the GD-500 sensor to the LogiComm control module NOTE: The sensor is IP56 (NEMA 4) rated. Required Equipment Make sure that the following items are available for installation: GD-500 controller GD-500 sensor Mounting brackets GD-500 controller and sensor interconnect cable LogiComm interface cable Trigger and trigger cable GD-500 controller key GD-500 manual Unpack the GD-500 Sensor 1. Carefully unpack the contents of the box. Exercise care to prevent equipment damage during unpacking. 2. Inspect for any damage that may have occurred during shipping. Report any damage to your Nordson representative.

14 10 GD-500 Bead Detection System Dimensions The dimensions of the GD-500 controller and the sensors are as follows: GD-500 Controller Figure 5 1. Magnet location GD-500 controller dimensions GD-500 Folding Carton Sensor Figure 6 Folding carton sensor dimensions

15 GD-500 Bead Detection System 11 GD-500 Corrugated Sensor Figure 7 Corrugated sensor dimensions Mounting Guidelines Observe the following guidelines when installing the GD-500 sensor: Make sure that the mounting location provides sufficient clearance for easy access to the connectors and the associated cables. Select a location to provide access to the operator panel for programming. The sensor is designed to operate between 0 and 50 C (32 and 122 F). The sensor arms must be kept free of dirt, dust, and adhesive.

16 12 GD-500 Bead Detection System Mount the GD-500 Sensor The GD-500 sensor must be mounted on the bracket assembly. Proper mounting of the adhesive sensors is important to obtain optimum operation of the liquid adhesive detection system. Folding Carton System Figure 8 1. GD-500 sensor 2. GD-500 arms 3. Lower guide bar Mounting the sensor and trigger on a folding carton bracket assembly 4. Protection bars 5. Trigger 6. Folding carton bracket assembly 7. Adapter for wheel pot 8. Straight line mounting bar 9. Adjustment arm

17 GD-500 Bead Detection System 13 See Figure Mount the sensor assembly (bracket, sensor, and trigger) on the machine using one of the following methods: For straight line gluing use the straight-line mounting bar (shipped installed) For wheel pot installation install the wheel pot mounting adaptor (shipped un-installed). 2. Make sure that the sensor arms are protected by the protection bars of the bracket to avoid damage to the sensor. 3. Align the opening in the bracket so the product passes freely through the opening. The lower guide bar must be at the same height as the belt of the machine. 4. Align adhesive pattern with the optimum sensing point on the sensor, marked by a dot on the short sensor arm. 5. Align the reference point of the trigger with the sensor, as shown below: Figure 9 Trigger reference line

18 14 GD-500 Bead Detection System Corrugated System Figure 10 Mounting the sensor and trigger on a bracket assembly for corrugated machines 1. Corrugated market bracket assembly 2. Sensor 3. Sensor arms 4. Protection bars 5. Lower guide bar 6. Trigger

19 GD-500 Bead Detection System 15 See Figure Mount the sensor assembly (bracket, sensor, and trigger) on the machine. 2. Make sure that the sensor arms are protected by the protection bars of the bracket to avoid damage to the sensor. 3. Align the opening in the bracket so the product passes freely through the opening. The lower guide bar must be at the same height as the belt of the machine. 4. Align adhesive pattern with the optimum sensing point on the sensor, marked by dots on the short sensor arm. 5. Align the the reference point of the trigger with the sensor so that the flap can be tracked at the same time. See the following figure: Figure 11 Trigger reference line Mount the GD-500 Controller Install the controller using the magnets. The magnets are installed on the back of the controller.

20 16 GD-500 Bead Detection System Cable Connections Figure 12 Cable connections

21 GD-500 Bead Detection System 17 Connector Name Connecting Device 1. S (Sensor) Connects from the GD-500 controller to the GD-500 sensor. 2. Tin (Trigger in) Connects from the GD-500 controller to a trigger (photocell). The following connectors (items 3, 4, and 5) are bundled together as a single harness: 3. Tout (Trigger out) Connects from the GD-500 controller to any Trigger input connector on the control module. The harness is connected to Trigger B1 on the control module, as shown in Figure Enc (Encoder) Connects from the GD-500 controller to the Encoder Repeater connector on the Master I/O panel of the control module. 5. LC (LogiComm) Connects from the GD-500 controller to two Sensor input connectors on the Verification panel of the control module. 5a. Glue Connects to the Glue sensor input. The harness is connected to Sensor B1, as shown in Figure 12. 5b. Excess Connects to the Excess sensor input. The harness is connected to Sensor B2, as shown in Figure Port Nordson use only.

22 18 GD-500 Bead Detection System Setup GD-500 Controller Operator Panel Use the operator panel to program the system for operation. Refer to Operator Panel Buttons and LEDs for details on the component functionality. Figure 13 Operator panel 1. Display panel 2. Operator panel buttons

23 GD-500 Bead Detection System 19 Operator Panel Buttons and LEDs Button Name Function Dynamic calibration and Run Menu button Button: Press this button for 2 seconds for the system to activate Dynamic Calibration mode. LED: Turns green to indicate that the system is in run mode, and turns yellow during dynamic calibration. Decrease value button Increase value button Service Menu button Button: Press this button decrease the value of a parameter. LED: Not used. Button: Press this button increase the value of a parameter. LED: Turns green to indicate a trigger signal. Button: 1. Press this button for 2 seconds to activate the Service menu. 2. Press this button to scroll through the menu screens. LED: Turns yellow to indicate that the system is ready for setup.

24 20 GD-500 Bead Detection System Operational Overview The GD-500 system monitors the amount of liquid adhesive on a product by measuring the dielectric coefficient of the material passing between the sensor arms. The dielectric measurement is directly related to the amount of adhesive on the carton or other substrate. The GD-500 controller learns the correct amount of adhesive during an automated dynamic calibration process, see item 7 in Figure 14. The alarm levels are then set to monitor the upper (MAX) and lower (MIN) deviations from the calibration level. Figure 14 Calibration and tolerance settings 1. Machine direction 2. Carton 3. Glue flap 4. Glue bead 5. Trigger 6. Sensor signals a: Glue input b: Excess input 7. Calibration 8. Flap

25 GD-500 Bead Detection System 21 There are two outputs from the GD-500 that connect to LogiComm sensor inputs: Glue and Excess. The Glue sensor input provides a signal to LogiComm when glue is detected. The Excess sensor input provides a signal to LogiComm when too much glue is detected (above the MAX limit). For additional details on Glue and Excess refer to Cable Connections under Installation. Also see item 6 in Figure 14 for the status of the two inputs at different signal levels. Figure 15 Glue and Excess output settings as it appears on the Monitor screen of the touch-screen panel The sensor is also sensitive enough to read the change in dielectric measurement due to the carton passing between the sensor arms, see item 8 in Figure 14.

26 22 GD-500 Bead Detection System Operational Overview (contd) To eliminate false signals from the carton, the sensitivity is adjusted, see Figure 16. If the sensitivity threshold level is set too high, the glue output will sense the board or the glue, and will not change at all. If the sensitivity threshold level is set too low, the glue output will change as soon as the edge of the board enters between the sensor arms. The correct sensitivity setting is shown in the following figure: Figure 16 Sensitivity threshold setting 1. Machine direction 2. Carton 3. Glue flap 4. Glue bead 5. GD-500 sensor 6. Sensor signal a: Sensitivity level high b: Sensitivity level correct c: Sensitivity level low 7. Glue output signal a: Sensitivity level high b: Sensitivity level correct c: Sensitivity level low

27 GD-500 Bead Detection System 23 Service Menu Setup Procedures Once the system is installed, power on the LogiComm System and then power up the GD-500 controller and sensor. NOTE: The GD-500 system gets power from the 24 VDC output of the LogiComm Sensor input. Run Mode The system will start up in Run Mode. The Run button LED will turn green to indicate that the system is in Run Mode. Begin the setup procedure by pressing for two seconds. You will enter the Service menu, and the Service menu button LED will turn yellow.

28 24 GD-500 Bead Detection System Sensor Trigger Offset (STO) Press to move to the STO setting menu. Enter the STO distance in millimeter by pressing or. Refer to Figure 17 to determine the STO distance. Figure 17 STO settings 1. Machine direction 2. Carton 3. Glue flap 4. Glue bead 5. Trigger 6. GD-500 sensor 7. STO 8. Sensor signal 9. Trigger signal NOTE: The default STO value is 30 mm. For the Folding Carton bracket in standard mounting, the STO distance is approximately 30 mm (1.18 in.). For the Corrugated bracket the STO distance is approximately 34 mm (1.33 in.).

29 GD-500 Bead Detection System 25 Calibration Samples Press to move to the Calibration Samples menu. This setting determines how many pieces the sensor will measure when performing a calibration, refer to Figure 14 for calibration and tolerance settings. The sensor will calculate the average measurement of the programmed number of samples. Press or to select a number between 1 and 10. The typical setting is five.

30 26 GD-500 Bead Detection System Minimum Tolerance Press to move to the Minimum Tolerance menu. Minimum tolerance is the amount below the calibrated signal level where the glue output signal will no longer indicate the presence of glue. Press or to select minimum tolerance. The default setting is 15% and the range is 0 100%. Figures 18 and 20 and the corresponding LogiComm Sensor touch-screen panel screens show two examples of minimum tolerance defects. Figure 18 Minimum tolerance settings Example 1 showing low glue amount or not enough glue 1. Not enough glue or low glue amount 2. Sensor signal 3. Maximum setting See Example 1 settings as it appears on the touch-screen panel: 4. Calibration 5. Minimum setting Figure 19 Bead error screen

31 GD-500 Bead Detection System 27 Figure 20 Minimum tolerance settings Example 2 showing broken glue bead 1. Broken glue bead 2. Sensor signal 3. Maximum setting 4. Calibration 5. Minimum setting See Example 2 settings as it appears on the touch-screen panel: Figure 21 Bead error screen

32 28 GD-500 Bead Detection System Maximum Tolerance Press to move to the Maximum Tolerance menu. Maximum Tolerance is the amount above the calibrated signal level where the max output signal will indicate excess glue. Press or to select maximum tolerance. The default setting is 15% and the range is 0 100%. See Figure 22 and the corresponding LogiComm Sensor touch-screen panel screen for an example of a maximum tolerance defect caused by excess glue. Figure Heavy glue bead 2. Sensor signal Maximum tolerance setting 3. Maximum setting 4. Calibration 5. Minimum setting See the excess glue settings as it appears on the Monitor screen of the touch-screen panel: Figure 23 Excess glue settings

33 GD-500 Bead Detection System 29 Sensitivity Threshold Press to move to the Sensitivity Threshold menu. The Sensitivity Threshold setting sets the overall range of the sensor signal. Refer to Figure 16 for the correct sensitivity threshold setting. Press or to select sensitivity setting. The default setting is 50% and the range is 1 99%. NOTE: Press gain) and press signal gain). to increase the Sensitivity Threshold (reduces the signal to reduce the Sensitivity Threshold (increases the Encoder Ratio Press to move to the Encoder Ratio menu. The Encoder Ratio setting sets the number of pulses per millimeter of the encoder. Press or to select encoder ratio. The default setting is 1.0 pulses per mm. The range is pulses per mm.

34 30 GD-500 Bead Detection System Language Press to move to the Language menu. Press or to select the desired Language. The default setting is English. Software Version Press to move to the Software Version menu. The Software Version menu displays the current version of software installed in the GD-500 system. This screen is not programmable. Return to Run Mode Return to Run Mode by pressing off.. The Service menu button LED turns When to Adjust Service Settings Under normal operation, the Service menu settings do not change. After a product changeover the sensitivity may need to be adjusted for a different board material. The maximum and minimum settings may be changed for the requirements of different products.

35 GD-500 Bead Detection System 31 Dynamic Calibration Mode Setup Procedure Dynamic Calibration is the process that teaches the GD-500 controller the expected amount of adhesive by measuring the signal from the programmed number of products as they pass through the sensor. Dynamic Calibration can be started from the GD-500 controller operator panel or from the LogiComm touch-screen panel. Calibrate the GD-500 System from the GD-500 Controller Operator Panel To calibrate from the GD-500 controller operator panel follow these steps: 1. Start the Dynamic Calibration by pressing for two seconds, until the button LED turns from green to yellow. The display will change to Dynamic Calibration mode, see figure on the left. 2. Run the line normally, applying the desired adhesive pattern. The GD-500 controller display panel will show one bar on the screen for each product to be learned. As each product passes under the sensor, the bars will count down as each product is learned. When the programmed number of products has passed under the sensor, the system returns to Run mode.

36 32 GD-500 Bead Detection System Calibrate the GD-500 System from the LogiComm Touch-screen Panel To calibrate from the touch screen panel follow these steps: 1. On the Main Menu screen, select the sensor associated with GD-500 glue input (for e.g. B1). 2. Touch the Learn Pattern button on the Sensor Menu screen, and the following pop-up screen will appear: Figure 24 Initial learn pop-up screen 3. Touch the Calibrate button, then touch the OK button. The initial learn pop-up screen will change to the following: Figure 25 Calibration pop-up screen NOTE: Once the above pop-up screen appears, the calibration process has started in the GD-500 system. The GD-500 controller LEDs will change from green to yellow, and the display panel will change to Calibration mode, see figure under Calibrate the GD-500 Controller from the GD-500 Controller Operator Panel. 4. Touch the Cancel button to exit the Calibration pop-up screen. The GD-500 will complete the calibration process after learning the programmed number of products.

37 GD-500 Bead Detection System 33 Learn Pattern Setup on the LogiComm Touch-screen Panel The final step in setting up the GD-500 system is to configure the two pattern verification sensors on the LogiComm System. NOTE: It is recommended that you name the two sensors according to their function, for e.g. GD-500 Glue and GD-500 Excess. You can assign sensor names using the Sensor Names menu on System Setup Page 4. Glue Sensor Input Set-up The Glue sensor input is an input that is activated when the measured glue amount exceeds the programmed minimum threshold. This input is usually monitored using template gluing. Template gluing is a verification algorithm that compares the measured pattern to a learned template and alarms any defects outside of the programmed tolerance limit. To set up template verification for glue sensor input: 1. On the Main Menu screen, select the sensor associated with GD-500 glue input (for e.g. B1). 2. Touch the Inspection Parameters button. 3. Set the desired tolerance for the start and stop position of the glue pattern, typically using the All Beads settings. 4. Touch the OK button to exit this screen. Excess Sensor Input Set-up The Excess sensor input is usually best monitored using the maximum setting on a cumulative bead algorithm. Cumulative bead will identify a defective product any time the input is on for longer than the programmed maximum limit. The maximum limit should be set to the maximum allowed length of excess glue that is acceptable for the application. The minimum setting is not used for this function and should be set to zero. To set up maximum setting for excess sensor input: 1. On the Main Menu screen, select the sensor associated with GD-500 excess input (for e.g. B2). 2. Touch the Inspection Parameters button, and then touch the Cumulative Bead button to enable the settings 3. Define the measurement position in the Cumulative Bead pop-up screen using the Delay and Duration settings. 4. Set the minimum setting to zero and the maximum setting according to the application. NOTE: Alternately, the excess glue input can also be monitored using template verification as described in Glue Sensor Input Setup.

38 34 GD-500 Bead Detection System Example of Glue and Excess Input Application The following figure shows an example of a GD-500 system application and the corresponding LogiComm sensor screens display the settings as it appears on the touch-screen panel. Figure 26 Example showing the glue and excess sensor input settings 1. Machine direction 2. Carton 3. Glue flap 4. Glue bead 5. GD-500 sensor Figure 27 Example showing the glue sensor input settings on the touch-screen panel

39 GD-500 Bead Detection System 35 Figure 28 Example showing the excess sensor input settings on the touch-screen panel

40 36 GD-500 Bead Detection System Maintenance The unit is virtually maintenance-free. Check cables regularly for damage. Replace damaged cables immediately. Clean the parts without using solvents. Remove adhesive splashes simply using a damp cloth. CAUTION: Do not use sharp tools to clean the sensor arms. Using sharp tools will damage the sensor arms.

41 GD-500 Bead Detection System 37 Parts List To order parts, call the Nordson Customer Service Center or your local Nordson representative. GD-500 Parts for Folding Carton Machines Part Description Quantity GD500, FOLDING CARTON SYSTEM GD500 CONTROL BOX GD500 FOLDING CARTON SENSOR GD500 SENSOR CABLE, 5 MTR GD500, FOLDING CARTON BRACKET GD500, SENSOR BRACKET GD500, SIDE ADJUSTMENT BRACKET GD500, ADAPTER PLATE, STRAIGHTLINE BR GD500 BRACKET, ADAPTER FOR WHEEL POT SCREW ALLENHEAD M8x12, DIN912,SS,A2, WASHER, M5, DIN433, SS, A SCREW ALLENHEAD M5x16, DIN912,SS,A2, PHOTOCELL, LA650, NPN/PNP HARNESS, 10M, LOGICOMM, GD CABLE, EXT. PHOTOCELL, LCOMM/LA404, 5M SCREW ALLENHEAD M3X20 DIN 912,SS, A2, NUT HEX M3, DIN934, SS, A2, WASHER M3, DIN NUT HEX M6, DIN934, SS, A WASHER, M6, DIN433, SS, A2 2

42 38 GD-500 Bead Detection System GD-500 Parts for Corrugated Machines Part Description Quantity GD500, CORRUGATED SYSTEM GD500 CONTROL BOX GD500 CORRUGATED SENSOR GD500 SENSOR CABLE, 5 MTR CORRUGATED STATION, GLUE DETECTION UNIT CORR.BRACK. LAD MANIFOLD CORR.BRACK. LAD SHAFT LOCKING BOLT WITH SPRING M CGS, DETECTION, UPPER GUIDE ASSY CGS, DETECTION, LOWER GUIDE ASSY WASHER, SPRING, M4, DIN SCREW ALLENHEAD M4x8 DIN 912, BLACK, CGS, DETECTION, BRACKET PHOTOCELL WASHER, SPRING, M5, DIN7980, ZINC PLATED SCREW ALLENHEAD M5x12, DIN912, 8.8, BLACK HARNESS, 2M, LOGICOMM, GD PHOTOCELL INLINER CABLE, PHOTOC., DIN MALE 5P/M12, 5M, LCOM 1

43

44

Seal Sentry Series 10 Bead Detection System

Seal Sentry Series 10 Bead Detection System Seal Sentry Series 10 Bead Detection System Customer Product Manual P/N 321 289D02 This equipment is regulated by the European Union under WEEE Directive 2002/96/EC). See www.nordson.com for information

More information

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT Sponge Cleaner Manual P/N 768 651 A English Issued 05/03 NORDSON (UK) LTD STOCKPORT Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected

More information

Hot Melt Material Applicator MC 7

Hot Melt Material Applicator MC 7 Hot Melt Material Applicator MC 7 Parts List P/N 735003A English Issued 2/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation

More information

FillEasy C Adhesive Feed System

FillEasy C Adhesive Feed System FillEasy C Adhesive Feed System Customer Product Manual Issued 5/10 This document contains important safety information Be sure to read and follow all safety information in this document and any other

More information

Hot Melt Applicators SB60 BoD

Hot Melt Applicators SB60 BoD Hot Melt Applicators Manual - English - Edition 06/14 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document applies to the entire series. Order number P/N = Order number for Nordson articles Note

More information

AltaSpray Plus Applicators

AltaSpray Plus Applicators AltaSpray Plus Applicators Customer Product Manual Issued 5/3 This document contains important safety information Be sure to read and follow all safety information in this document and any other related

More information

Series AD-31 and Series L4 Extrusion Handguns

Series AD-31 and Series L4 Extrusion Handguns Series AD-31 and Series L4 Extrusion Handguns Customer Product Manual Issued 5/05 NORDSON CORPORATION DULUTH, GEORGIA USA www.nordson.com For CE Declaration, refer to melter documentation. Nordson Corporation

More information

Hot Melt Material Applicator MC 4420

Hot Melt Material Applicator MC 4420 Hot Melt Material Applicator Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This is

More information

DuraDrum Bulk Melters DD200

DuraDrum Bulk Melters DD200 DuraDrum Bulk Melters Manual English Issued 11/07 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

LA 820 / LA 820 RC Liquid Adhesive Gun

LA 820 / LA 820 RC Liquid Adhesive Gun Liquid Adhesive Gun Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by

More information

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Bulk Melters BM 200 with Piston Pump - EASY Pneumatics - Manual - English - Issued 05/06 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note After approx. December 2003, this manual applies to the entire series.

More information

U7698E Flame Detector

U7698E Flame Detector U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General

More information

Bulk Melters AltaPail

Bulk Melters AltaPail Bulk Melters AltaPail Manual - English - Edition 02/12 NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This document is for products with the following P/N: 7165698 7157455 7157502 7157503 Order number

More information

Level Monitor LA 100

Level Monitor LA 100 Level Monitor LA 100 Manual English NORDSON BENELUX MAASTRICHT THE NETHERLANDS www.nordson.com Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which

More information

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION Fill Sentry Automated Fill System Customer Product Manual Part NORDSON CORPORATION www.nordson.com CAUTION: If this equipment is used with other Nordson equipment, refer to the manuals provided with that

More information

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD Electropneumatic Hot Melt Application Heads Manual P/N 409 090 A English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson

More information

Hot Melt Application Head Series PW...

Hot Melt Application Head Series PW... Hot Melt Application Head Series... Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice This

More information

Envirocoat Twin Cyclone Powder Coating Booth

Envirocoat Twin Cyclone Powder Coating Booth Envirocoat Twin Cyclone Powder Coating Booth Manual P/N 779166 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue

More information

Hot-melt adhesive extruder EEX40

Hot-melt adhesive extruder EEX40 Hot-melt adhesive extruder EEX40 Manual 110900563/001 - English - Nordson Deutschland GmbH Buchholz-Mendt GERMANY Note This manual applies to the entire series. Part number P/N = 7549584 Notice This is

More information

Hot Melt Material Applicator MC 6

Hot Melt Material Applicator MC 6 Hot Melt Material Applicator Manual P/N 403 022 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums Manual P/N 464 958 C - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order

More information

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Material Applicator MC 12 / MC 24 Hot Melt Material Applicator Manual P/N 403 076 D English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products Notice

More information

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Piston Pump for 200 l Drums Bulk Melters BM 200 with Piston Pump for 200 l Drums Manual P/N 464 937 B - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number

More information

Hot Melt Applicator MC 405 for Foil Bags

Hot Melt Applicator MC 405 for Foil Bags Hot Melt Applicator for Foil Bags Manual English NORDSON ENGINEERING GMBH LÜNEBURG GERMANY NOTE This manual is for products with the following P/N: 8015767 8022490 8027924 8037680 8018042 8023117 8031127

More information

Hot-melt adhesive extruder EEX100

Hot-melt adhesive extruder EEX100 Hot-melt adhesive extruder EEX100 Manual 111121287/001 -- English -- NordsonDeutschlandGmbHBuchholz--MendtGERMANY Note This manual applies to the entire series. Part number P/N = 7552471 Notice This is

More information

Powder Conditioning System

Powder Conditioning System Powder Conditioning System Manual P/N 779168 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Table I Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF,

More information

Drum Melters DG 21 / DG 201

Drum Melters DG 21 / DG 201 Drum Melters DG 21 / DG 201 Manual P/N 464 839 A - English - NORDSON ENGINEERING GMBH LÜNEBURG GERMANY Note This manual applies to the entire series. Order number P/N = Order number for Nordson products

More information

DC200 Digital Dispenser Operating Manual

DC200 Digital Dispenser Operating Manual DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

Fixed Reclaim System

Fixed Reclaim System Fixed Reclaim System Manual P/N 779163 --English-- Keep for Future Reference Nordson China Sourcing - Shanghai Trademarks AccuJet, Aquaguard, Asymtek, Automotive, Autotech, Blue Box, CF, Can Works, Century,

More information

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK Manual P/N 768 643 A English NORDSON (UK) LIMITED STOCKPORT UK Order number P/N = Order number for Nordson products Notice This is a Nordson Corporation publication which is protected by copyright. Original

More information

FC-2200 Flame Detector

FC-2200 Flame Detector FC-2200 Flame Detector Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence

More information

Liquid Adhesive Detection System Alarm Box

Liquid Adhesive Detection System Alarm Box Liquid Adhesive Detection System Alarm Box Customer Product Manual Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products.

More information

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS

Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQXS Hot -melt adhesive extruder EEX100 -F5B2X2TWXMQX Manual 110717869/001 -- English -- Nordson Deutschland GmbH D Buchholz--Mendt D GERMANY Note This manual applies to the entire series. erial no. 110717869/001

More information

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model Part456A NORDSON CORPORATION. AMHERST, OHIO USA Corporation welcomes requests for information, comments and inquiries about its products.

More information

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA Customer Product Manual Issued 10/08 NORDON CORPORATION AMHERT, OHIO UA afety... 1 Qualified Personnel... 1 Intended Use... 1 Regulations and Approvals... 1 Personal afety... 1 High-Pressure Fluids...

More information

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10 ColorMax Engineered Booth Customer Product Manual Issued 11/10 For parts and technical support, call your nearest Finishing Customer Support Centre. Find your nearest centre at www.nordson.com/directory

More information

Safety Enclosure for Automated Dispensing Systems

Safety Enclosure for Automated Dispensing Systems Safety Enclosure for Automated Dispensing Systems Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www.nordsonefd.com You have selected a reliable, high-quality dispensing

More information

FS10-R30 Flame Detector

FS10-R30 Flame Detector FS0-R0 Flame Detector Customer Product Manual Part 00-0 Issued 0/ For parts and technical support, call the Industrial Coating Systems Customer Support Center at (00) - or contact your local Nordson representative.

More information

IntelliDoX Operator Manual

IntelliDoX Operator Manual IntelliDoX Operator Manual OPERATOR MANUAL TABLE OF CONTENTS Table of Contents Table of Contents...1 About this Publication...3 Important Safety Information: Read First...4 Getting Started...5 About the

More information

Protégé Eclipse LED Keypad User Manual PRT-KLES

Protégé Eclipse LED Keypad User Manual PRT-KLES Protégé Eclipse LED Keypad User Manual PRT-KLES The specifications and descriptions of products and services contained in this manual were correct at the time of printing. Integrated Control Technology

More information

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA Fiber Optic Module Part NORDSON CORPORATION AMHERST, OHIO USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address all correspondence to Nordson Corporation

More information

Fuel Management System Setup Guide

Fuel Management System Setup Guide Fuel Management System Setup Guide EVO-EXPC & EVO-EXPC2 Expansion Consoles for TS-5000 evo and TS-550 evo Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787

More information

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45 LOUP II DRILL MONITOR OPERATION MANUAL SOFTWARE v45 Service and Technical Support Contact: Loup Electronics Inc. Address: 2960 N. 38th Street Lincoln, NE 68504 Phone: 877-489-LOUP(5687) 402-464-7131 Fax:

More information

Non-RTD Hot Melt Hose Replacement

Non-RTD Hot Melt Hose Replacement Instruction Sheet P/N 7C 0 Safety WARNING: System pressurized! Relieve system hydraulic pressure before breaking any hydraulic connection or seal. Failure to relieve the system hydraulic pressure can result

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver

Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver MDE-4511B Card System Interface and Electro-mechanical Totalizer Retrofit Kits for Atlas Commercial Electronic Units Installation Instructions June 2011 Introduction Purpose This document provides installation

More information

RTO. User guide 05/

RTO. User guide 05/ RTO User guide Version: RT0 M&S (master & slave) Characteristics: Constant lighting, temperature regulation with a low inertia heating system. Building opening hour scheduler and presence detection. 05/2013

More information

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root #

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root # Manual Number: 01-61-141 Revision : 1.7 Date: 10/27/16 Installation Instructions Remanufactured Veeder-Root Position Sensitive Sump Sensor PMP # 62323 Replaces Veeder-Root #794380-323 Contents Disclaimer...

More information

Smart thermostat with Humidification/De-humidification control

Smart thermostat with Humidification/De-humidification control x Smart thermostat with Humidification/De-humidification control Enter/Confirm Scroll Right = Increase Left = Decrease Back/Cancel TABLE OF CONTENTS Everyday Use 1. Adjusting Temperature...3 2. Adjusting

More information

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide Installation Guide P/N 1028657A Econo-Coat RCM 8000 Powder Spray Booth Installation Guide WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual Parameter Method ####, Operation & Maintenance Manual Rev 3/26/2018 Contact Information Document Information Customer Name: Plant Name/Location: Date: Analyzer Serial #: ASA, Inc. (Applied Spectrometry

More information

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER ENGLISH ESPAÑOL Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER MODEL : LP0817WSR LP1017WSR LP1217GSR LP1417SHR LP1417GSR

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors Manual Number: 01-61-133 Revision : 1.8 Date: 10/27/16 Installation Instructions Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors PMP # 62322, 62352 Replaces Veeder-Root

More information

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209 Manual Number: 01-60-291 Revision : 5.6 Date: 12/11/15 Installation Instructions Remanufactured Veeder-Root Sump Sensor PMP # 62208, 62209 Replaces Veeder-Root #794380-208, -209 Contents Disclaimer...

More information

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic USER MANUAL Version: 1.0 ROBE Show Lighting s.r.o. Czech Republic www.robe.cz Table of contents 1.Introduction 4 2.Cautions 4 3. Unpacking & Inspection 5 4. Setup 5 5. Operation 5 5.1.Control Module Operation

More information

918 Clock Gauge Installation, Operation, and Maintenance Instructions

918 Clock Gauge Installation, Operation, and Maintenance Instructions 98 Clock Gauge Installation, Operation, and Maintenance Instructions The 98 Clock Gauge is designed to measure liquid level in an aboveground storage tank. The gauge mounts on top of the tank and is activated

More information

Alarm System SECURE AS 302

Alarm System SECURE AS 302 Alarm System SECURE AS 302 Operating Manual SECURE Light app now available! Table of Contents Before You Start.................................. 4 User Information....................................4

More information

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 2 IP. GJD230 IP Motion Detector D-TECT 2 IP GJD230 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 2 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

Replacing a Gun Thermostat

Replacing a Gun Thermostat Instruction Sheet Replacing a Gun Thermostat WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all other related documentation.

More information

Models: GW/R-T GW/R-2-T GW/R-3-T

Models: GW/R-T GW/R-2-T GW/R-3-T Part# GW/R-T-OM 1/12/04 TN Models: GW/R-T GW/R-2-T GW/R-3-T This manual contains important information concerning the installation and operation of the gun washers listed above. Read manual thoroughly

More information

PORT700CF Portable Fume Collector

PORT700CF Portable Fume Collector 11975 Portland Ave. S. Suite 104 Burnsville, MN 55337 Phone: 952-894-6637 Fax: 952-894-0750 Email: info@ventaire.com Website: www.ventaire.com PRODUCT GUIDE FOR PORT700CF Portable Fume Collector REV:110314

More information

D-TECT 3 IP. GJD260 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector D-TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D-TECT 3 IP 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare sliding curtains 2 x Tamper feet 1 x Tamper

More information

Remote Temperature Controller

Remote Temperature Controller Remote Temperature Controller Technical Manual Part 07 97A NORDSON CORPORATION. AMHERST, OHIO. USA Nordson Corporation welcomes requests for information, comments and inquiries about its products. Address

More information

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans Operating Instructions Edition 11/2005 Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA sitrans Introduction 1 General safety instructions 2 SITRANS Process monitoring Ex-barrier

More information

INLINE DI HEATER. Operation / Maintenance Manual

INLINE DI HEATER. Operation / Maintenance Manual INLINE DI HEATER Operation / Maintenance Manual PATENTS: U.S. 5971402, U.S. 6433319, U.S. 6479094B2, U.S. 6544583B2, U.S. 6580061B2, U.S. 6663914, U.S 6674053B2; ADDITIONAL PATENTS PENDING 11/12/15 MIDH

More information

This presentation is courtesy of

This presentation is courtesy of This presentation is courtesy of Waterborne Adhesive Application Equipment Presented by: Presented by: Chuck Chuck Waychoff Waychoff North American Sales Manager North American Sales Manager Paper & Paperboard

More information

Paradox Integration Module Settings Guide

Paradox Integration Module Settings Guide Paradox Integration Module Settings Guide List of Terms used in Paradox Integration Module Settings Guide............. 3 Introduction into Paradox Integration Module Settings Guide............... 4 Configuration

More information

Installation and operation manual

Installation and operation manual Installation and operation manual - + BRC1HHDAW BRC1HHDAS BRC1HHDAK English Table of contents Table of contents 1 General safety precautions 2 1.1 For the user... 2 1.2 For the installer... 2 2 About this

More information

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC 2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101 Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

Slot-Die Coater. User Manual. enabling materials science. Manual Version: 1.0.E Product code: L2005 Product Version: 1.0 Software Version: 1.

Slot-Die Coater. User Manual. enabling materials science. Manual Version: 1.0.E Product code: L2005 Product Version: 1.0 Software Version: 1. Slot-Die Coater Manual Version: 1.0.E Product code: L2005 Product Version: 1.0 Software Version: 1.0 enabling materials science ossila.com Contents Contents... 2 1. Overview... 4 2. EU Declaration of Conformity

More information

HOBO U14 Data Logger User Manual

HOBO U14 Data Logger User Manual HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity

More information

SYMS III MANUAL SEALER

SYMS III MANUAL SEALER MANUAL SEALER For CBS High Security straws, CBS High Security tubes and HSV High Security Vitrification Straw Copyright Cryo Bio System 2015 Cryo Bio System - ZI n 1 Est 61300 L Aigle contact@cryobiosystem-imv.com

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460 Manual Number: 01-60-309 Revision : 5.5 Installation Instructions Remanufactured Veeder-Root Steel Tank Interstitial Sensor PMP # 62420, 62460 Replaces Veeder-Root #794380-420, -460 Contents Disclaimer...

More information

Original operating instructions Safety switch with guard locking AC901S AC902S

Original operating instructions Safety switch with guard locking AC901S AC902S Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5

More information

3M Benchtop Air Ionizer 963E. User s Guide

3M Benchtop Air Ionizer 963E. User s Guide 3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.

More information

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY Table of Contents Non-Programmable Heat Pump Thermostat Installation Manual 97B0082N06 Revised: 16 September, 2013 Safety Considerations 3 General 3 Package Contents 3 Installation Considerations 3 Power

More information

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E

Installing the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E Overview 1 2 SIMATIC Getting Started 03/2013 A5E03973659-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as

More information

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. SYSTEM USER GUIDE SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM If

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Installation and user manual

Installation and user manual Installation and user manual Please read carefully and retain for future reference Models EcoHeat: C3, C5, C6, C8, C9, C11, C12 Rev.1_09-07-15 Page 1 Table of Contents 1 IMPORTANT: WARNINGS 1.1 GENERAL

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections. ISSUES ISSUE DATE RELEASED DETAILS OF CHANGE AUTHOR 4 Rev 2 September 2004 Changes for 4000 series. DB 4 Rev 3 April 2005 Screen shots updated and other minor changes K.Z. 4 Rev 4 September 2006 4 Rev

More information

SYMS II MANUAL SEALER

SYMS II MANUAL SEALER SYMS II MANUAL SEALER Dedicated to CBS High Security straws, CBS High Security tubes, and HSV High Security Vitrification Kits Copyright Cryo Bio System 2010 Cryo Bio System - ZI n 1 Est 61300 L Aigle

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

2012 Toolbar & NH3 Operators Manual

2012 Toolbar & NH3 Operators Manual 2012 Toolbar & NH3 Operators Manual P/N 320379 Amity Technology, LLC 2800 7th Avenue North Fargo, ND 58102 (701) 232-4199 www.amitytech.com This Page Left Intentionally Blank Page 2 2012 Toolbar/NH3 Manual

More information