CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
|
|
- Ethan Cunningham
- 5 years ago
- Views:
Transcription
1 SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-8CA RCW-8HA RO-8CB RO-8HB C O N T E N T S SPECIFICATIONS OUTLINE AND DIMENSIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM DIAGRAM ERROR CONTENTS INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM DISASSEMBLY ILLUSTRATION PARTS LIST
2 SPECIFICATIONS TYPE COOL COOL & HEAT INDOOR UNIT RCW-8CA RCW-8HA OUTDOOR UNIT RO-8CB RO-8HB COOLING CAPACITY (kw) HEATING CAPACITY (kw) ELECTRICAL DATA POWER SOURCE (V) 0-40 FREQUENCY (Hz) 50 RUNNING COOLING (A) CURRENT HEATING INPUT COOLING WATTS (kw) HEATING COOLING E.E.R. (kw/kw) HEATING STARTING CURRENT (A) 4 MOISTURE REMOVAL ( /h). AIR CIRCULATION-Hi (m 3 /hr) 650 COMPRESSOR TYPE Hermetic type, Rotary DISCRIMINATION JS38D5BA0 POWER SOURCE 0-40V 50Hz REFRIGERANT R- (g),50,500 FAN MOTOR POWER SOURCE (V) 40 DISCRIMINATION MFA-8GTT MFA-8GTBT INDOOR HI-SPEED (r.p.m.) 80 UNIT MED-SPEED (r.p.m.) 740 OUTDOOR UNIT LO-SPEED (r.p.m.) 60 DISCRIMINATION MFB-4JTBT FAN SPEED (r.p.m.) Hi : 800 Lo : 400 DIMENSIONS INDOOR UNIT 35 x 580 x OUTDOOR UNIT H x W x D (mm) 650 x 830 x 30 GRILLE 35 x 650 x 650 WEIGHT INDOOR UNIT 3 / 8 OUTDOOR UNIT GROSS / NET (kg) 55 / 5 60 / 56 GRILLE 4.3 /. - -
3 MODELS REFRIGERANT CIRCUIT CONDITION PIPING RCW-8CA RO-8CB RCW-8HA RO-8HB DISCHARGE COOLING.0.0 PRESSURE kg/cm G HEATING SUCTION COOLING PRESSURE kg/cm G HEATING DISCHARGE COOLING 73 8 TEMP. HEATING REFRIG. PIPE LENGTH m 7.5 DISCHARGE COOLING 3 AIR TEMP. HEATING INDOOR ENTERING AIR TEMP. OUTDOOR ENTERING AIR TEMP. DB/WB DB/WB COOLING 7.0 / 9.0 HEATING 0.0 / ---- COOLING 35.0 / 4.0 HEATING 7.0 / 6.0 PIPE DIA. LIQUID 6.35 mm SIZE GAS.7 CONNECTION METHOD HEIGHT Max. 8 BETWEEN m PIPE LENGTH Max. 0 REFRIGERANT TYPE R- Flare REFRIGERANT CHARGE (R-) MODELS PIPE LENGTH 7.5 m 0 m 5 m 0 m Additional refrigerant FULL CHARGE AMOUNT RCW-8CA RCW-8HA,50 g,88 g,63 g,338 g 5 g / m,500 g,575 g,75 g,875 g 30 g / m - -
4 OUTLINE AND DIMENSIONS INDOOR UNIT (unit : mm) ( 650) (Grille measurement) 650 (Hanging bolt position) 400 (Hanging bolt position) Drain pipe (I.D. 3) (Ceiling opening measurement)
5 OUTDOOR UNIT (unit : mm) Bottom Air flow
6 CIRCUIT DIAGRAM Models : RCW-8CA / RO-8CB INDOOR UNIT FLOAT SWITCH THERMISTOR (ROOM TEMP.) THERMISTOR (PIPE TEMP.) DISPLAY BOARD CN TO OUTDOOR UNIT TERMINAL M STEP MOTOR GREEN/ FM FAN MOTOR M DRAIN PUMP MOTOR ORANGE BLUE PURPLE CN CN5 CN7 CN6 CN 3 CN8 CONTROL BOARD 3 CN5 CN4 FAN MOTOR CAPACITOR ORANGE BLUE CN3 CN9 3 PURPLE CN N L Use T3.5A-50V Fuse on F0 FILTER BOARD GREEN (N) (L) OUTDOOR UNIT BLUE THERMAL PROTECTOR INTERNAL OVERLOAD PROTECTOR R FAN MOTOR C S COMPRESSOR CAPACITOR FAN MOTOR CAPACITOR COMPRESSOR MAIN RELAY FUSE 5A TERMINAL L N (L) (N) TO POWER SUPPLY TO INDOOR UNIT - 5 -
7 Models : RCW-8HA / RO-8HB INDOOR UNIT FLOAT SWITCH THERMISTOR (ROOM TEMP.) THERMISTOR (PIPE TEMP.) DISPLAY BOARD CN TO OUTDOOR UNIT TERMINAL FAN MOTOR STEP MOTOR GREEN/ FM FAN MOTOR CAPACITOR M ORANGE BLUE PURPLE PINK CN CN5 M CN7 CN8 CONTROL BOARD 3 CN5 ORANGE BLUE CN6 CN 3 PURPLE CN3 CN CN9 3 N L Use T3.5A-50V Fuse on F0 FILTER BOARD GREEN DRAIN PUMP MOTOR BLUE (N) (L) OUTDOOR UNIT BLUE THERMAL PROTECTOR INTERNAL OVERLOAD PROTECTOR R FAN MOTOR C S COMPRESSOR CAPACITOR FAN MOTOR CAPACITOR COMPRESSOR MAIN RELAY FUSE 5A 4-WAY VALVE COIL SV TERMINAL L N (L) (N) TO POWER SUPPLY TO INDOOR UNIT - 6 -
8 REFRIGERANT SYSTEM DIAGRAM Models : RCW-8CA / RO-8CB INDOOR UNIT OUTDOOR UNIT Refrigerant pipe 6.53mm(/4") Capillary tube Dryer Evaporator Condenser Refrigerant pipe.7mm(/") Charging valve Compressor Models : RCW-8HA / RO-8HB INDOOR UNIT OUTDOOR UNIT Refrigerant pipe 6.35mm(/4") Dryer Compressor Capillary tube Capillary tube Evaporator Accumulator Muffler Strainer Strainer Condenser Cooling Heating : Flare coupling Refrigerant pipe.7mm(/") Charging valve Check valve 4-Way valve - 7 -
9 ERROR CONTENTS Operation can be checked by lighting and flashing of the grille display section OPERATION and TIMER lamps. Perform judgment in accordance with the following. CHECK ITEMS. INDOOR UNIT SWING TIMER OPERATION MANUAL AUTO () Is operation of each button on the remote control unit normal? () Does each lamp light normally? (3) Do not air flow direction louvers operate normally? (4) Is the drain normal? (5) Is there any abnormal noise and vibration during operation? SWING LAMP (Orange) TIMER LAMP (Green) OPERATION LAMP (Red). OUTDOOR UNIT TEST RUNNING When the air conditioner is run by pressing the remote control unit test run button, the OPERATION and TIMER lamps flash slowly at the same time. ERROR The OPERATION, TIMER, and SWING lamps operate as follows (Table ) according to the error contents. () Is there any abnormal noise and vibration during operation? () Will noise, wind or drain water from the unit disturb the neighbors? (3) Is there any gas leakage? Do not operate the air conditioner in the test running state for a long time. Error display OPERATION TIMER SWING lamp lamp lamp Table Error contents Blinks Blinks Goes off Model information abnormal (permanent type) Pulses 4 times Blinks Goes off Drain abnormal (permanent type) Pulses 6 times Blinks Goes off Indoor fan abnormal Pulses times Blinks Goes off Blinks Room air temperature thermistor open circuit Room air temperature thermistor short circuit Pulses 3 times Blinks Goes off Blinks Piping thermistor open circuit Piping thermistor short circuit - 8 -
10 Model : RCW-8CA INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM UL05 AWG4 UL05 AWG4 L TM0 N TM0 R 3.3 <5W> UL05 AWG6 GREEN FH0 E0 FAN CAPACITOR.0uF 480VAC TERMINAL BOARD E D D3SB60 C5 00/450V F0 3.5A <BET> SA0 3600V F M FAN MOTOR POWER SOURCE 0 / 40V 50Hz OUTDOOR UNIT W03 UL05 AWG8 UL05 AWG8 UL05 AWG8 BLUE PURPLE + FH0 DRAIN PUMP R4 330K <W> Q SC436 R3 00 R.5 <W> VA0 470V M VA0 470V W04 UL05 AWG0 UL05 AWG0 Q SC85 C0 0. UL05 AWG8 UL05 AWG8 UL05 AWG8 UL05 AWG8 UL05 AWG8 BLUE L UL05 AWG8 PURPLE M UL05 AWG8 H C6 4700P R7 330 </4W> CN- CN4- CN5- CN5- CN5-6 CN5-5 CN5-4 C D DFL0U D3 MTZJ5.B LF0 ELF7N05A K3 G5S- CN5-3 JM5 CN5 B6P-VH-B UL05 AWG UL05 AWG R5 6K <W> D5 SR D0 SR C03 C04 CN BP3-VH-B-C CN- CN4 BP3-VH-B-Y CN4- H I LO R6 00 </W> D4 DFL0U C8 + 00/6.3V C05 C06 PRIMARY POWER SUPPLY PCB EZ-003SWSE-P CN9 BP3-VH-B-R CN9- CN6 BP3-VH-B-E CN6- CN6- CN-3 CN- K G5S- CN BP3-VH-B-R T SWITCHING TRANSFORMER ZFT9B0 D6 DFL0U C0 0. CR8 TA0033 C3 0. R88 0 </W> K6 G5S- C54 K8 G5NB-A K4 G5NB-A CN6- K5 G5NB-A C4 0. R89 0 </W> C9 000 / NOT USED JM R8.0K P5 P0 76 CUSTOM CODE SWITCHING JM R9.0K P6 CUSTOM CODE SWITCHING JM3 R0.0K 3 P7 I C + SECONDARY R 56K <W> JM6 VA 470V + - SSR G3MC-0P-VD NO. NO. NO.3 TEST 4V R8 0K D8 DF60 SW DSS803 I C9 TLP6 (D4) - GB CN9- CN9- CN9-3 CN9-4 CN9-5 4V R38 0K R37 0K R39 0K CN9 B5P-SHF-AA R3 0K I C K 4 K 3 K NC NC NC K 8 NC K 5 K 6 AUTO RESTART SWITCHING I O G R.0K R - R4 0K X 4 R5 - R7 0K x 3 C3 0. C V 9 R93 - R96 0K x 4 7 I C5 (6/7) 8 4V upa003gr C4 00/ 6.3V C7 R4 R4 R40 ROOM TEMPERATURE CORRECTION ( HEATING OPERATION ) ROOM TEMPERATURE CORRECTION ( HEATING OPERATION ) R0 0K C6 - C9 x 4 I C6 (5/7) upa003gr R5 - R8.0K x 4 C0 C.0K x 3 R9 - R3 x 3 0K x 4 R33 - R36.0K x 4 C - C5 X 4 CONTROLLER PCB ASSEMBLY ( MAIN PCB ) EZ-003SWSE-C C9 - C x 3 C5 0. R9 390 Q3 DTC4EKA C GND JM0 7 I C C30 P upd780058bgc BT P57 74 VDD0 P56 68 VDD 75 AVREF0 7 AVREF 4 AGND P GND0 7 XT NC 63 CR6 36 P60 37 P6 38 P6 39 P63 40 P64 4 P P0 P33 P34 P35 P37 5 P0 9 P40 0 P4 P4 56 P4 P P5 58 P6 59 P7 43 P67 44 P30 45 P3 46 P3 X X P70 P7 P7 P5 P5 P53 P54 P55 P0 P50 P7 P6 P5 P P P0 P P36 50 P 53 P45 P44 P P46 5 P4 5 P3 4 P47 6 P 54 P3 55 P05 P04 P66 P4 P3 P P XT 73 RESET 60 C3 000P <R> C35 000P <R> R77 - R79 0K x 3 I C4 (7/7) upa003gr 6 7 4V 9 I C6 (/7) upa003gr C43 R44.0K R46.0K R50 0K CR5 000P <R> R56 NC R7.0K C6 C3 R58 R75 R76 R00 R59 R97 R98 R99 CR CR CR3 R8.0K R7.0K 0K 0K 0K 0K 0K 0K 0K 0K 0K 0K 0K CR4 0K JM R55 0K C44 0. C CR D0 VCC 8 3 D NC 7 CK NC 6 CS GND 5 I C7 BR93LC46RF R5 K R67.0K I C8 PST600C 3 5 R43 0K (%) R K (%) C39 0. R54 47 I C5 (/7) upa003gr NC NC NC NC R57.0K 4V C34 0. C37 0. R53 0K BZ PKM3EPY-4000 R80 0K R69 0K R70 0K B Z R68.0K C45 0. C 0. RJ 0K C49 Q4 DTC4EKA R49.0K C38 R5 0K + C4 0/ 4V RJ 0K CN5- CN5- CN5-3 CN5 B3B-XARK--A R R48 0K CN3 B8B-XASK--A CN3- CN3- CN3-3 CN3-4 CN3-8 CN3-5 C4 CN3-7 CN3-6 UL430 AWG UL430 AWG ORANGE PURPLE BLUE CN0 B5B-XASK--A UL430 AWG8 CN0- CN0- CN0-3 CN0-4 CN0-5 CN8 BB-XASK--A CN7 BB-XAKK--A CN4 B8B-XASK--A UL430 AWG8 ORANGE CN8- CN8- CN7- CN7- CN4-4 CN4-3 CN4- CN4- ORANGE PURPLE BLUE ORANGE HA JEM-A R0 330 </4W> R0 330 </4W> R </4W> CN0 7P-SCN FLOAT SWITCH ROOM TEMPERATURE THERMISTOR HEAT EXCHANGER THERMISTOR SW0 MANUAL AUTO SWITCH EVQ-PAG-04K DISPLAY PCB EZ-097HHSE-D M D0 SLR-35 <> D0 SLR-35 <GRN> D03 SLR-35 <ORG> C0 0/ + C0 0. LOUVER ( UP / DOWN ) OPERATE TIMER LOUVER OUT PHA0 SBX
11 DISASSEMBLY ILLUSTRATION Models : RCW-8CA RCW-8HA
12
13 Model : CG-E
14 Models : RO-8CB RO-8HB
15 Model : RO-8CB
16 Model : RO-8HB
17 Model : RO-8CB Model : RO-8HB
18 Models : RO-8CB RO-8HB
19 PARTS LIST RCW-8CA RCW-8HA INDOOR UNIT When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Ref. No. Description RCW-8CA Part No. RCW-8HA Ord. Q'ty Ref. No. Description RCW-8CA Part No. RCW-8HA Ord. Q'ty 34 Capacitor (Fan Motor) Rubber Special Washer M Drain Hose Separate Wall-A Evaporator Assy-IN Inlet Pipe (Eva. ) Assy Drain Pan Fan Motor Assy-IN Thermo. Spring-A Rubber Bushing Clamp No Clamp SKB Control Box Outlet Pipe (Eva. ) Assy Thermistor Assy-Room Thermistor Assy-Pipe Controller PCB Assy Remote Control Unit Pipe Cover Drain Port Special Nut-A (Large) Special Nut-B (Small) Separate Wall-B Turbo Fan Turbo Fan Rubber Special Nut M Special Washer Special Washer Sensor M. Bracket Float Switch Pump Unit Hanger Metal Drain Pan Plug Clamp No. U Control Box Cover Locking Spacer-B EMI Filter Therm. Holder Pipe Remote Control Holder Case Cap (Power) Clamp NK-N Hooking Wire Motor Fixture Locking Spacer Supporter (Eva. ) Air Duct Supporter-A Clamp NK-7N Drain Pan Support Separate Wall-C Pump Hook Bracket Terminal-7P Fuse Wire Cover Cushion-A (For Pump) Cushion-B (For Pump) Filter PCB Assy Flare Nut-A Flare Nut-B Top Cover Plate Body-A Body-B Cord Clamp-A Cord Clamp-B GRILLE ASSY (CG-E) Ref. No. Description Part No. Ord. Q'ty Ref. No. Description Part No. Ord. Q'ty 93 Filter Motor Cover Clamp SKB Motor Gear Indicator PCB Assy Cover-A Insulation (Panel)-A Insulation (Panel)-B Joint-A Joint-B Joint Shaft Cam Gear Panel Louver Intake Grille Filter Clamp-A Filter Clamp-B Decoration Plate Receiver Cover Grille Stopper Grille Hook Step Motor-V
20 RO-8CB RO-8HB OUTDOOR UNIT When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. Ref. No. Description RO-8CB Part No. RO-8HB Ord. Q'ty Ref. No. Description RO-8CB Part No. RO-8HB Ord. Q'ty Fan Guard Emblem-Rear Front Panel Ptd Connector Cover (Cabinet) Wire Assy (Comp) Side Panel R Ptd Base Assy Ptd Way Valve Way Valve Dryer Condenser Assy Discharge Pipe Assy Discharge Pipe-A Discharge Pipe-B Compressor Cover-A Separate Wall Control Box Capacitor, Plastic Running Capacitor Capacitor Clamp Metal Bolt, Hex. Socket Valve Plate Ptd Rubber Seat-A Terminal Cover (Comp) Clip (Cable) Relay Muffler Way Valve Rubber Accumulator Suction Pipe-B Suction Pipe-C Solenoid Way Valve Accum. Support Assy Cvr Gasket (Comp) Protection Net Inlet Pipe (Cond) Assy Top Panel Terminal Gasket Washer Joint Pipe (Valve) -A Propeller Fan Assy Motor, Induct Motor Bracket Motor Bracket-Top Motor Bracket-Ctr Motor Bracket-Bottom Compressor Assy Rubber (Discha. Pipe) Special Nut M Special Nut M Terminal-7P Terminal-8P Joint Pipe (Valve) -B Fuse Holder Fuse Condensing Pipe Assy Condensing Pipe Capillary Assy Strainer-B Cord Clamp-A Suction Pipe-A Suction Pipe-A Side Panel L, Ptd Cord Clamp-B Air Seal Plate
21 STANDARD ACCESSORIES INDOOR UNIT ACCESSORIES Name and Shape Application Part No. Coupler heat insulation For indoor side pipe joint Special nut A (large flange) For installing indoor unit Special nut B (small flange) For installing indoor unit Template For ceiling hole cutting Remote control unit Battery (penlight) Use for air conditioner operation For remote control unit (Cooling model) (Cooling & Heating model) Remote control unit holder For mounting the remote control unit Tapping screw ( 3 x ) For remote control unit holder installation OUTDOOR UNIT ACCESSORIES Name and Shape Drain Pipe Application For outdoor unit drain piping work [Heat & Cool (Reverse cycle) model only] Part No GRILLE ASSY ACCESSORIES Bolt Name and Shape Application For opening the refrigerant valve on the outdoor unit Part No Washer For mounting grille Blower cover insulation For discharged air
22 040J59 January 004 Printed in Japan
CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationRC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit RCW-54CB RO-50CA RC-54CA RO-50CA RC-54HA RO-50HA CONTENTS SPECIFICATIONS OUTLINE AND DIMENTIONS CIRCUIT DIAGRAM REFRIGERANT SYSTEM
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationCEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARG25ALC ARG25RLC ARY25ALC ARY25RLC ART25ALC ART25RLC ARG30ALC ARG30RLC ARY30ALC ARY30RLC ART30ALC ART30RLC AOG25ANBL AOG25RNBL
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationFLOOR CONSOLE / UNDER CEILING DUAL type
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT
More informationDUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit RD-25CA RD-25HA RD-30CA RD-30HA RO-25CA RO-25HA RO-30CA RO-30HA C O N T E N T S SPECIFICATIONS.............................................
More informationDUCT type. SPLIT TYPE AIR CONDITIONER (50Hz)
SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARY0ELA AOY0EPBL CONTENTS SPECIFICATIONS.............................. OUTLINE AND DIMENSIONS...................... CIRCUIT DIAGRAM............................
More informationFLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25ALC-W AUG25ALQ-W AUG25RLC-W AUG30ALC-W AUG30ALQ-W AUG30RLC-W AOG25AZCL AOG25AZQL AOG25RZCL AOG30ABML AOG30ABSL AOG30RBML
More informationCASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.
SPLIT TYPE AIR CONDITIONER CASSETTE type (60Hz) Models Indoor unit AUU8RCLX AUURCLX AUU6RCLX AUURCLX Outdoor unit AOU8RLX AOURLX AOU6RLX AOURLX CONTENTS SPECIFICATIONS... DIMENSIONS... REFRIGERANT SYSTEM
More informationWALL MOUNTE SPLIT T YPE ROOM AIR CONDITIONER. type. Models. Models. Outdoor Unit Serial No. Starting with T ( Compressor Recipro type )
SPLIT T YPE ROOM AIR CONDITIONER WALL MOUNTE type Models Outdoor Unit Serial No. Starting with T000001 ( Compressor Recipro type ) Indoor unit ASU18C1 ASU18R1 ASU24C1 ASU24R1 ASU30C1 Outdoor unit AOU18C1
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFW AOURLXFW CONTENTS SPECIFICATIONS.................... DIMENSIONS........................ REFRIGERANT SYSTEM
More informationASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT
WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT Indoor unit ASU8RLF ASURLF Outdoor unit AOU8RLXFWH AOURLXFWH CONTENTS SPECIFICATIONS.................... DIMENSIONS........................
More informationAUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS
SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit AUXG8LRL AUXGLRL UTG-UKYA-W Outdoor unit AOYG8LCA AOYGLCA CONTENTS SPECIFICATIONS.................... DIMENSIONS....................... REFRIGERANT
More informationC E IL IN G W A L L SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE ROOM AIR CONDITIONER C E IL IN G W A L L t y pe Models Indoor unit Outdoor unit AWY24LBAJ AOY24LMAL AOY30LMAL CONTENTS SPECIFICATIONS................................ 1 OUTLINE AND DIMENSIONS..........................
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606
MODEL-ICE0250, ICE0400, ICE0500, ICE0606 ICE SERIES CUBERS SERVICE PARTS MANUAL Includes 50HZ units Mile High Equipment 11100 East 45th Ave Denver, Colorado 80239 Print Date 03/03 * This parts list contains
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081299-01 Rev 8/08 # This parts
More informationParts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-901MAJ KM-901MWJ KM-901MRJ/3 hoshizakiamerica.com Number: 71391 Issued: 10-23-2017 Revised: 6-8-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationCU1526, CU2026, CU3030 Service Parts
This is the illustrated list of service parts for all models of the CU, CU0 and CU00 self contained ice machines. These machines were manufactured in several voltages, which is designated by a numeric
More informationTAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE040427 Models TAC-07CS/K TAC-09CS/K TAC-2CS/K TAC-8CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-2CHS/K TAC-8CHS/K TAC-24CHS/K CONTENTS. IMPORTANT
More informationSERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications
CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM SERVICE Manual AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Block Diagrams
More informationParts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3 hoshizakiamerica.com Number: 71375 Issued: 5-15-017 Revised: 10-3-018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More informationSERVICE Manual FREE JOINT MULTI AIR CONDITIONER
FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More informationParts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com
Parts List Stackable Crescent Cuber Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3 hoshizakiamerica.com Number: 71384 Issued: 8-31-2017 Revised: 3-26-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering
More information6868 Ardmore Street Houston, Texas Toll Free Phone Fax
P-09 P-09 P-09A COMPONENT PART NO. COMPONENT PART NO. BASE PAN 67904000 AIR OUTTAKE 67809008 OUTDOOR CENTRIFUGAL FAN 67809032 TURNING WHEEL (CASTER) 67904001 (4) ERECT LOUVER ASSY 67809006 (5) OUTDOOR
More informationCME1856W Service Parts
This parts list contains the part numbers and description of the replacement parts available for this model. To avoid costly and time consuming errors, double check the model and voltage before ordering
More information4. Disassembly and Reassembly
4. Disassembly and Reassembly Stop operation of the air conditioner and remove the power cord before repairing the unit. 4-1 Indoor Unit 4-1-1 MH FPEA /MH VP2-1 Front Panel 1) Stop the air conditioner
More informationParts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-1100MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71392 Issued: 12-12-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More informationHoshizaki America, Inc.
Hoshizaki America, Inc. Commercial Series Refrigerated Kitchen Equipment Models CRA-FS CRA-HS CFA-FS CFA-HS A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71309 Issued: 7-1-011 CONTENTS
More informationNM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...
This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM9 SERVICE PARTS TABLE OF CONTENTS
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A
TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before
More informationAFE400 SERVICE PARTS
This is the parts list for the AFE00. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationSERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications
SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT SERVICE Manual SYSTEM AIR CONDITIONER CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Set Up the
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338
TECHNICAL & SERVICE MANUAL SA 128S5 FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-128S5-A 1 851 004 09 General (50Hz) & Europe SA 128S5 REFERENCE NO. SM700338 IMPORTANT!
More informationUNIT PANELS 6/25/ :15:30 AM Page 2 of 27
MF56 1 UNIT PANELS 2 REFRIGERANT SYSTEM AIR COOLED 3 REFRIGERANT SYSTEM WATER COOLED 4 WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 WATER SYSTEM AND INSULATIONS - FROM S.N. 23385 TO S.N. 24159 6 WATER
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationParts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-340MAJ, MWJ hoshizakiamerica.com Number: 71389 Issued: 10-23-2017 Revised: 6-12-2018 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationMDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6
This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing parts to be sure that this is the correct parts list. There have been several
More informationNM1850 SERVICE PARTS
This parts list contains the service parts and wiring diagrams for this model. Check the model number in question to be sure that it is applicable to this parts list. NM0 SERVICE PARTS TABLE OF CONTENTS
More informationParts Manual Frigoglass/Universal Nolin/Beverage Air - MT27
Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT7 Page of 0 0079 00696 PANEL,SIDE,MT7//9/7 LEFT, 06 0079 00697 PANEL,SIDE,MT7//9/7,RIGHT, PRE-PAINTED PRE-PAINTED 0790 BPS-6C0007A 00086 GRILLE,KIT,REPLACEMENT,MT7,BLACK.0
More informationFM1500 SERVICE PARTS
This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine needing the parts to be certain that this is the correct parts list. FM00 SERVICE PARTS
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationCMS1402 SERVICE PARTS
This parts lists shows the service parts for the CMS1402 air cooled and the CMS1402 water cooled. A B model was introduced in early 1992, the major change was the front panels. Check the model number of
More informationSERVICE Manual AIR CONDITIONER AW0719 AW Precautions. 2. Product Specifications. 3. Operating Instructions and Installation
ROOM AIR CONDITIONER AW079 AW089 SERVICE Manual AIR CONDITIONER CONTENTS. Precautions 2. Product Specifications 3. Operating Instructions and Installation 4. Disassembly and Reassembly 5. Troubleshooting
More informationTCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE031229 Models TAC-07CS/K TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CSC/K TAC-09CSC/K TAC-12CSC/K TAC-18CSC/K TAC-24CSC/K TAC-07CHS/K
More informationTechnical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.
Technical Support Division 2017-4-25 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram
More informationCHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION
CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION PART NUMBER BY CAPACITY 9/12 15 18/24 30 36/42 48 1 1 FRONT PANEL W/LOUVER 550-373 550-373 550-374 550-374 550-388
More informationEXPLODED VIEWS & PARTS LISTS
542 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More informationSERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305
SERVICE PARTS MANUAL The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305 ICE-O-Matic Print Date 04/05 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081332-01 * This parts list contains
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07LMCE ASYG09LMCE ASYG12LMCE ASYG14LMCE OUTDOOR AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE DR_AS037EF_01 2016.12.05 Notices: Product
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS1271 & PNR-XS1872 + CH1271 XHS1872 & PNR-XS1872 + CH1872 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS1271
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-325MAJ KML-325MWJ hoshizakiamerica.com Number: 71377 Issued: 4-7-2017 Revised: 9-8-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts...
More informationКондиционеры Mitsubishi Heavy
Кондиционеры Mitsubishi Heavy Техническое руководство Кондиционеры настенного типа SRK28HD, SRK40HD INDOOR UNIT Models SRK28HD, SRK40HD OUTDOOR UNIT Model SRC28HD REMOTE CONTROLLER Model SRC40HD GENERAL
More informationSERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.
SERVICE MANUAL Indoor unit Outdoor unit 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* INDEX PART1 GENERAL INFORMATION PART2 ELECTRICAL DIAGRAM PART3 TROUBLE
More informationRAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E
FILE NO. A0-05 SPLIT TYPE RAS-0JKVP-E RAS-0JAVP-E RAS-3JKVP-E RAS-3JAVP-E PRINTED IN JAPAN, Jun.,003 ToMo . EXPLODED VIEWS AND PARTS LIST -. Indoor Unit () 0 0 6 35 5 4 0 5 33 7 08 6 07 9 3 0 3 8 30 39
More informationAIR-CONDITIONER SERVICE MANUAL
FILE NO. A90-9608 SERVICE MANUAL AIR-CONDITIONER S SPLIT BUILT-IN DUCT TYPE RAV-362B-PE/ RAV-462B-PE/ SPLIT CEILING TYPE RAV-362C-PE/ RAV-462C-PE/ SPLIT CASSETTE TYPE RAV-362U-PE/ RAV-462U-PE/ PRINTED
More informationSERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units
SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units ICE-O-Matic 11100 East 45th Ave Denver, Colorado 80239 Part Number 9081307-01 Rev 3/06 * This parts list contains
More informationINVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)
TECHNICAL MANUAL & PARTS LIST DRAFT INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK20ZD-S - 1 - INDOOR UNIT Model SRK20ZD-S OUTDOOR UNIT Model SRC20ZD-S REMOTE
More informationRANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.
BAKE ELEMENT RANGE BAKE ELEMENT ADMIRAL AMANA CALORIC GLENWOOD HARDWICK IMPERIAL MAGIC CHEF MAYTAG WHIRLPOOL ROPER SUNRAY WELBILT 308180 2600/1950 Watts 240/208 Volts.250 male terminal push-in connection
More informationWALL MOUNTED TYPE ROOM AIR-CONDITIONER
TECHNICAL MANUAL & PARTS LIST DRAFT WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type) SRK50HE-S, SRK56HE-S (Split system, air cooled cooling only type) SRK50CE-S, SRK56CE-S
More informationParts and Service Manual
Section II Parts and Service Manual (70241A) CLARKE TECHNOLOGY Operator's Manual - MINI MAX Page -29- Frame and Front Cover Assembly Drawing 2/01 Page -30- CLARKE TECHNOLOGY Operator's Manual -MINI MAX
More informationSERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS
SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS SPECIFICATION... 1 FUNCTIONS... 5 SERVICE FUNCTION EXPLANATION... 7 OPERATION DETAILS... 8 TROUBLESHOOTING GUIDE... 13 PERFORMANCE
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationParts List. Low-Profile Modular Crescent Cuber. Models KML-500MAJ KML-500MWJ. hoshizakiamerica.com
Parts List Low-Profile Modular Crescent Cuber Models KML-500MAJ KML-500MWJ hoshizakiamerica.com Number: 71378 Issued: -8-017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main Assembly
More informationDC INVERTER SPLIT SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL XHS7 & PNRXS87 + CH7 XHS87 & PNRXS87 + CH87 FILE NO. Destination: North America DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) XHS7 (PNRXS87) XHS87 (PNRXS87)
More informationMega Top Sandwich Prep Table Manual
Mega Top Sandwich Prep Table Manual Model SUSS-27-12 1. Technical Specifications Amp 115V 3.4A Connection 15 amp plug Name R134a Refrigerant Q'ty (oz) 3.2 Q'ty (gram) 90 HP 1/5 HP Compressor Samsung SD162C-L1U2
More informationCompact 4-way Cassette ( ) Type
E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference
More informationParts Manual Frigoglass/Universal Nolin/Beverage Air - MT49
Parts Manual Frigoglass/Universal Nolin/Beverage Air - MT9 Page of NR 0 0079 00696 PANEL,SIDE,MT7//9/7 LEFT, NR 06 0079 00697 PANEL,SIDE,MT7//9/7,RIGHT, 090 998060 000898 GRILLE, MT, BTM 6 9999070 008
More informationService Manual & Installation Manual
GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR
More informationParts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com
Parts List Modular Crescent Cuber Models KM-515MAJ, MWJ, MRJ hoshizakiamerica.com Number: 71390 Issued: 10-23-2017 Revised: 11-17-2017 CONTENTS Auxiliary Codes... 3 Note About Ordering Parts... 3 A. Main
More informationGlobal-Tek (Singapore) Pte Ltd
Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz
More informationWater Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL
Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL-906-41 Compressors - Compressor Arrangements Compressors - Compressor Arrangements Q ty/unit No. Parts No. Parts Name
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationSpare Parts Catalogue MF56
Spare Parts Catalogue MF56 1 - UNIT PANELS 2 - REFRIGERANT SYSTEM AIR COOLED 3 - REFRIGERANT SYSTEM WATER COOLED 4 - WATER SYSTEM AND INSULATIONS - UP TO S.N. 23384 5 - WATER SYSTEM AND INSULATIONS - FROM
More informationAir Conditioner Service Manual
Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 MODEL: AC-S7HGB 3 CONTENTS TECHNICAL SPECIFICATION..4
More informationService Parts for models UF424 and UN324
Service Parts for models UF and UN This is the illustrated parts list for Scotsman ice maker models UF and UF. They were manufactured as either air or water cooled models, plus the air cooled models were
More informationSERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT. DocID: 00G00010EA
SERVICE MANUAL OFFICE PRO 36 SERIAL NUMBER FROM APRIL 2007 (0407) TO PRESENT DocID: 00G00010EA 2008 DENSO SALES CALIFORNIA, INC. All rights reserved. This book may not be reproduced or copied, in whole
More informationMDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5
This is the list of service parts for the MDT2C12A-1A and MDT2C12A-1B ice maker dispensers. The B series model began in late 2014. It has a number of electrical differences from the prior model. Always
More informationMcQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007
Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied
More informationCASSETTE TYPE AIR CONDITIONER
CASSETTE TYPE AIR CONDITIONER (5, / 3, BTU/h) TECHNICAL MANUAL Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. CONTENTS. FEATURES....
More informationParts List. Modular Flaker F-1501MAH(-C) F-1501MWH(-C) F-1501MRH(-C) hoshizakiamerica.com
Parts List Modular Flaker F-1501MAH(-C) F-1501MWH(-C) F-1501MRH(-C) hoshizakiamerica.com Number: 71353 Issued: 7-9-2014 Revised: 12-14-2017 CONTENTS Note About Ordering Parts... 3 A. Main Assembly & Refrigeration
More informationRoom Air Conditioner Service and Parts Manual
Cool Dry Temp Mode Room Air Conditioner Service and Parts Manual F Fan Speed hr Timer 0n 0ff Money Saver Fan Only Auto Swing Power CP06 CP08 93011401_01 CONTENTS 1. PREFACE 1.1 SAFETY PRECAUTIONS...2 1.2
More informationCME1056 Service Parts. Table of Contents
This is the parts list for the CME0 ice machine. The CME0 was manufactured in A, D, E and F series, as well as single phase 0 Hz, single phase 0 Hz, and three phase. The E series change was to side panels
More informationImage Key Part Number Description Substitution Qty.
Model Number: BOM/Serial #: Graphic Title: XRSR465BW PXRSR465BW0 SUPPLEMENTAL INFORMATION Image Key Part Number Description Substitution Qty. 1 1 67002385 HARNESS-CONTROL 1 1 1 67002384 HARNESS, ICE MAKER
More informationDisplay Cases Deli Cases Service Manual
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Display Cases Deli Cases Service Manual Please read this manual completely before attempting
More information