INSTALLATION, OPERATING and SERVICE MANUAL

Size: px
Start display at page:

Download "INSTALLATION, OPERATING and SERVICE MANUAL"

Transcription

1 ISTAATIO, OPERATIG and SERVICE MAUA TE ISTAATIO OF TE UIT SA BE I ACCORDACE WIT TE REGUATIOS OF TE AUTORITIES AVIG JURISDICTIO. E Electric Furnace EAD OFFICE MARKETIG / PRODUCTIO ewmac Mfg. Inc. DEBERT AIR IDUSTRIA PARK, ACASTER CRESCET P.O. BOX 9, DEBERT OVA SCOTIA, BOM G0 POE: FAX: WAREOUSE ewmac Mfg. Inc. 0 SPRIGBAK AVE., SOUT P.O. BOX WOODSTOCK, OTARIO S 7Y POE: FAX: EMAI: newmac@ca.inter.net Website: newmacfurnaces.com OTICE TO OMEOWER: READ AD SAVE TESE ISTRUCTIOS 007 MAY 00

2 MODE E CETRA EECTRIC WARM AIR FURACE GEERA ISTRUCTIOS It is the responsibility of the consignee of the unit to examine the package for damages and, if found, to note the same on the Carrier's Bill of ading. The furnace is shipped in one package. This includes the furnace assembly complete with elements, controls, blower, motor and casing, filter rack, filters, thermostat and instruction booklet. The furnace has 0 volt elements and for 0volt, wire, 0 volt blower motor, or 0/0volt, wire, 0 volt blower motor. All furnaces are phase, 0 z. See furnace label and this manual for more details. Model 0 BTU/hr Output Static Pressure ins wc Temp Rise F Blower Motor A Minimum Circuit Ampacity, A Maximum Circuit Fuse, A Air Filter 0V 0/0V 0V 0/0V 0V 0/0V E0* 0,0 0.0/0.0 / E*,80 0.0/0.0 / E0* 0 8,0 0.0/0.0 0/ 8 E* 8,00 0.0/0.0 0/ 8 0 E0* 0 0,0 0.0/0.0 / Model 0v BTU/hr Output Static Pressure ins wc Temp Rise F Blower Motor A Minimum Circuit Ampacity, A Maximum Circuit Fuse, A Air Filter 0v 0/0v 0v 0/0v 0v 0/0v E9* 9 0, /0.0 0/ E*.,0 0.0/0.0 0/ E8* 8, 0.0/0.0 0/ E*. 7, /0.0 /0 8 8 E7* 7 9, 0.0/0.0 0/ 8 0 *D Direct Drive, /P, speed motor, 0v, or 0v. Delhi G0-8 or Airdex DDblower. *DS Direct Drive, /P, speed motor, 0v. G0-8 or direct drive blower. *B Belt Drive, /P, 0v or 0v, 7 rpm motor. G0-8 or belt drive blower. E0 to E0 elements are kw, 0 volts. E9 to E7 elements are.kw, 0 volts. Control circuit is volts. Blower motor fuse: 0v - CR type D time delay. 0v TRM8 miniature time delay. CEARACE TO COMBUSTIBES The ewmac E Electric Furnace may be installed in the up-flow, down-flow, horizontal-left or horizontal -right positions with the following clearances to combustibles: Sides 0" Rear 0" Front (For Servicing) " Warm Air Plenum and Duct 0" cate the furnace to provide: Best heat distribution Shortest supply cable east interference with present or future plans. ISTA TO CODE This furnace shall be installed in accordance with the CSA Standard C., Canadian Electric Code, and the requirements of the authority having jurisdiction. These instructions are intended as a general guide and do not supersede local codes. Consult local authorities before installation. POWER CABE Use 7 C copper supply sized according to the minimum ampacity. This should be connected to a separate fused disconnect switch to power the furnace. Suitable ground must be provided.

3 RETUR AIR AD FITER RACK The filter rack may be mounted on either side, the bottom or the back of the appliance. Position the rack so that there is easy access to change the filter. WARM AIR Before installing the plenum, look into the furnace and check the heating elements to ensure that no damage has occurred and that they are free of foreign material. TERMOSTAT and ATICIPATOR Should be installed according to the instructions packed with it and connected to the volt terminals on the front of the appliance. The heat anticipator should be set to 0. amps. BOWER SPEED AD STATIC PRESSURE The ewmac E Electric Furnace is tested and approved by CSA for static pressures of 0.0 to 0.0 ins wc. The 0.0 ins wc static pressure setting is for normal use and the units are factory equipped with the blowers set to provide this. The 0.0 ins wc static pressure setting is for air conditioning. The installer should set the required blower speed - see table below. Set the speed of the belt-drive-blower units by adjusting the motor pulley. Adjust this pulley to give the recommended air temperature rise. SEQUECE OF OPERATIO As the room temperature drops, the thermostat contacts will close and energize the heating element on the first sequencer. After approximately 0 seconds, the first set of contacts in the sequencer will close, bringing on the # element. At the same time the circulating blower will start. After approximately 0 seconds, the # element will come on. Depending on the model, and if the furnace is set to i, #, #, #, and # elements will come on in sequence. See below for more information on the i/econo switch setting. When the room thermostat is satisfied, it will break contact. All the elements will turn off in random sequence. The blower will stop when the last element shuts off. I/O COTIUOUS FA SWITC This is located on the front of the furnace and provides the homeowner with the option of having the circulating blower run continuously at high or low speed. This control does not affect the normal heating and cooling cycles of the furnace. I/ECOO EAT SWITC This switch is provided on some models. It is located on the front of the furnace and provides the homeowner with the option of manually increasing or reducing the heating power of the furnace. It can be used to manually switch from "i" to "Econo" if less heating power is temporarily desired, depending on the outdoor temperature. This switch can also be controlled automatically by a suitable multi- or two-stage thermostat connected to the W (Econo) and W (i) terminals. Set the switch to "Econo" if a two stage or multi-stage thermostat is used. If a standard thermostat is connected across W- R, a remote switch or an outdoor temperature switch can be connected across OT-W to switch from "Econo" to "i" as the outdoor temperature drops. eave the furnace switch in "Econo" if a remote or outdoor temperature switch is used. OT W W C G R OT W W C G R Remote Switch (Optional) eat/cool Thermostat OT W W C G R Remote Switch (Optional) stage eat/cool Thermostat eating Thermostat R = vac C = vac G = Fan Relay W = eat Relay Stage W = eat Relay Stage OT = (R) vac MAITEACE To maintain the performance of the furnace, replace or clean the air filter monthly. OMEOWER If you, the homeowner, suspect the furnace is not operating properly, or if there is no heat, do not tamper with the furnace. ave a qualified service person check out the furnace installation. BOWER REMOVA Turn off the main electricity power supply before servicing the furnace. Open the centre access panel to disconnect the wiring to the blower motor Open the blower access panel. Carefully unscrew the bolt(s) holding the blower assembly in place, and remove the entire blower/motor assembly by sliding it out through the access opening.

4 MODE STATIC PRESSURE IS WC VARIABE SPEED MOTOR PUEY (TO) STADARD BOWERS BOWER PUEY IS BE T IS DIRECT DRIVE SPEED CFM BET DRIVE CFM DIRECT DRIVE APPROX TEMP RISE F DIRECT E0* 0.0 -/" (0) 0, /" () 8, E* 0.0 -/" (0) 0 M,00, /" () 8 M,00,000 E0* 0.0 -/" (0) 0 Mi,00, /" () 8 Mi,00,00 0 E* 0.0 -/" (0) 0 Mi,00, /" () 8 Mi,00,00 E0* 0.0 -/" (0) 0 i,00, /" () 8 i,00,00 70 E9* 0.0 -/" (0) 0, /" () 8, E* 0.0 -/" (0) 0 M,00, /" () 8 M,00,000 0 E8* 0.0 -/" (0) 0 Mi,00, /" () 8 Mi,00,00 E* 0.0 -/" (0) 0 Mi,00, /" () 8 Mi,00,00 0 E7* 0.0 -/" (0) 0 i,00, /" () 8 i,00,00 * = B for belt-drive blower and D for direct-drive blower. ote actual cfm and rise are installation dependent. MODE IG CFM ( SPEED) BOWER STATIC PRESSURE IS WC DIRECT DRIVE SPEED CFM APPROX TEMP RISE F E0DS 0.0, EDS 0.0 Med, Med,0 0 E0DS 0.0 Med, Med,0 EDS 0.0 i, i,0 E0DS 0.0 i, i,0 E9DS 0.0, EDS 0.0 Med,0 0.0 Med,0 E8DS 0.0 Med,0 0.0 Med,0 0 EDS 0.0 i, i,0 0 E7DS 0.0 i, i,0 0 DS for direct-drive high cfm speed blower. ote actual cfm and rise are installation dependent.

5 M M E0D, E7D OT W W C G R M M S- M M M M M M M M M M S- M M M M S- M M WR Cap i E0B, E7B M M S- M M M M M M M M M M S- M M M M S- M M WR OT W W C G R optional eat and DS models eat i Econo Econo eat Relay eat Relay i v i v wire wire DD Blower Motor wire fils wire Motor =Black M( spd),m( spd)=blue M( spd)=orange =Red or =White Belt drive blower motor wire models (0v motor) 0/0v, ph, 0z Connect to,, and o fuse Connect to and WR90-7 heat relays 0/v transformer CR type D fuse WR90-7 heat relays 0/v transformer See motor lead colours See motor lead colours wire models (0v motor) 0v, ph, 0z WIRIG DIAGRAMS - E0, E7

6 eat ED, ED E0D, E8D OT W W C G R eat EB, EB E0B, E8B OT W W C G R M M M M S- M M M M M M S- M M Cap M DD Blower Belt Motor drive blower M motor WR Primaire WR i M M M M S- M M M M S- M M M M i optional Econo i Econo i wire wire and DS models wire wire E0D and E8D omit element and use S- in place of S- eat Relay eat Relay E0B and E8B omit element and use S- in place of S- v v Motor = Black M( spd),m( spd)=blue M( spd)=orange = Red wire models (0v motor) 0/0v, ph, 0z Connect to,, and o fuse Connect to and WR90-7 heat relays 0/v transformer CR type D fuse WR90-7 heat relays 0/v transformer See motor lead colours See motor lead colours wire models (0v motor) 0v, ph, 0z ExxD = speed direct drive ExxDS = speed direct drive ExxB = Belt drive WIRIG DIAGRAMS - E, E, E0, E8

7 OT W W C G R ED, ED EB, EB wire M M S- M M M M Cap M M i E0D, E9D and DS models E0D and E9D omit element and use S- in place of S- eat Relay WR M M M M S- M M WR OT W W C G R v i E0B, E9B optional v wire wire eat Relay v DD Blower Motor Motor = Black M( spd),m( spd)=blue M( spd)=orange = Red or =White wire Belt drive blower motor E0B and E9B omit element and use S- in place of S- wire models (0v motor) 0/0v, ph, 0z Connect to,, and o fuse Connect to and WR90-7 heat relays 0/v transformer CR type D fuse WR90-7 heat relays 0/v transformer See motor lead colours See motor lead colours wire models (0v motor) 0v, ph, 0z ExxD = speed direct drive ExxDS = speed direct drive ExxB = Belt drive WIRIG DIAGRAMS - E, E, E0, E9

8 E REPACEMET PARTS IST PART O. DESCRIPTIO PART O. DESCRIPTIO / p Direct Drive Motor - Speed (0v) 090 eating Element Blank Cover / p Direct Drive Motor - Speed (0v) 0 Front Access Panel (Wiring) / p Direct Drive Motor - Speed (0v) 08 Front Panel - Switch 0000 / p Belt Drive Motor (0v) 07 Side Panel R (" DD models) / p Belt Drive Motor (0v) 09 Side Panel (" DD models) 000 Variable Speed Motor Pulley -/" X /" 00 Rear Panel (" DD models) 000 Blower Pulley - " (0."Wc Static) 08 Blower Access Door (for " DD models) 000 Blower Pulley - " (0."Wc Static) 0 Side Panel R (0" BD models) 008 Blower Belt - 8" (For " Pulley) 07 Side Panel (0" BD models) 000 Blower Belt - 0" (For " Pulley) 0 Rear Panel (0" BD models) Direct Drive Blower assembly complete 0 Blower Access Cover (for 0" BD models) Direct Drive Blower 09 Air Filter Assembly Belt Drive Blower c/w " pulley 0 Base Panel Belt Drive Blower c/w motor hardware Motor Belly Band assembly, 0" 007 Manual Instructions 0 Blower egs () Thermostat (heating only) 0000 Capacitor - uf Capacitor - 7.uF 00 eating Element - kw, 0v 0080 Switch - Blower, i/ Continuous 00 eating Element -.kw, 0v 008 Switch - eat, i/econo 007 Sequencer, S- 008 Sequencer, S- 000 Thermo-O-Disc 0imit 009 Sequencer, S- 00 Fuse older (0v motor) for CR fuse " x 0" air filter 008 Fuse older (0v motor) for TRM8 fuse 007 A Fuse (0v motor models) CR type D 008 8A Fuse (0v motor models) TRM8 miniature 000 v Transformer (0v model) 0008 v Transformer (0v model) 0008 Cooling Relay (v coil) WR eating Relay (0v coil) WR eating Relay (0v coil) WR v terminal block (all models) 7

9 EWMAC imited Warranty Subject to the following provisions, ewmac Mfg. Inc. ("ewmac") warrants the heating unit under normal use and repair against defects in workmanship or material for a period of one year from the date of installation. Under this warranty, ewmac will replace or repair any defective part at no cost or expense to you except for the cost of delivery and labour in the removal of the defective part and the installation labour of the replacement part. This warranty is void if the unit is not installed, operated, maintained, and cleaned according to the owner's manual. The heating unit must be installed by a competent, qualified installer in accordance with our installation instructions, applicable codes and the ational Warm Air eating and Air Conditioning Association Standards or generally accepted equivalent standards. The warranty is void if any alteration is made to the heating unit without written authorization by ewmac. This warranty is the only warranty made by ewmac. ewmac does not authorize any person or company to provide any other warranty or to assume any further obligation in connection with the sale of this heating unit on its behalf. This warranty shall not apply to damage of the heating unit caused by misuse or failure to maintain the heating unit properly. This warranty does not apply to the installation or wiring not integral to the heating unit. The operation of the heating unit in a corrosive atmosphere (such as concentration of acids or halogenated hydrocarbons) is considered misuse and voids this warranty. This heating unit must be used and cared for in accordance with the instruction manual. The purchaser is responsible for required periodic maintenance such as changing or cleaning air filters and lubrication of components. See instruction manual for details. ewmac shall not be responsible for any consequential damage however caused whether by a defect in the heating unit or any part thereof warranted hereunder or by the negligence of any person. If the heating unit requires service, contact the dealer who installed the equipment originally, or an alternate qualified and registered heating dealer or electrician. As stated herein, ewmac does not assume responsibility for costs of delivery and labour involved in the replacement of defective parts. Unless otherwise directed by ewmac, defective parts must be returned to the ewmac plant; freight prepaid. Collect charges will not be accepted. Replacement parts will be supplied F.O.B. our factory. Whenever requesting service, please be sure to give the model and serial numbers located on the rating plate of your heating unit. This warranty is not effective unless the warranty registration card is properly filled out with all of the required information and received by ewmac at the address below within thirty (0) days of the installation date. Keep this warranty certificate and the instruction manual for future reference. PEASE PRIT OR TYPE Warranty Registration Owner's name Address of Installation Date of Installation Dealer's name Dealer's address Furnace serial number Furnace Model umber ewmac Mfg. Inc, P.O. Box 9, 08 ancaster Crescent, Debert, ova Scotia, Canada, B0M G0 8

Installation instructions for Plenum-mounted add-on electric heaters

Installation instructions for Plenum-mounted add-on electric heaters Installation instructions for Plenum-mounted add-on electric heaters Aug. 2008 Version 4 THESE INSTALLATION INSTRUCTIONS COVER: MODEL T-4 to T-30 (4 Kw to 30 Kw) GENERAL NOTES - Please refer to CSA Standard

More information

B SERIES ELECTRIC FURNACE

B SERIES ELECTRIC FURNACE MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual Conforto Electric Furnace KHE 10 TO 27kW INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual in its entirety

More information

POSITION FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A

POSITION FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A ALIMENTATION 240 VAC POWER SUPPLY MULTI POSITION Models: FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A DNS-0981 Rev. A

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION OPERATION INSTALLATION PARTS MANUAL www.fostoriaindustries.com Made in U.S.A. ELECTRIC PORTABLE HEATER FES-1024-1CA 08860010 YES-1024-1CA 08861510 FES-1520-3A 08860110 YES-1520-3A 08860810 FES-1524-1A

More information

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE Save These Instructions For Reference ALL SOM SERIES FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED

More information

Model REAC / SEAC Self Contained Cooling / Electric Heating Units

Model REAC / SEAC Self Contained Cooling / Electric Heating Units Model REAC / SEAC Self Contained Cooling / Electric Heating Units Supersedes: 145.30-IOM1 (708) Form 145.30-IOM1 (908) UNIT MODELS REAC / SEAC - R22 ELECTRIC HEATING / ELECTRIC COOLING INSTALLATION, OPERATION

More information

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES Save These Instructions For Reference ALL SUMMERAIRE SLO115 / SFLO115 MODELS ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL

More information

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. MARCH 2011 version 7 Installation instructions for Plenum-mounted add-on electric heaters MODEL TU MARCH 2011 version 7 THERMOLEC PLENUM HEATER MODEL TU BEFORE YOU START -GENERAL SAFETY AND INSTALLATION PRECAUTIONS Please

More information

Models: Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20. Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20

Models: Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20. Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20 Models: COMFORT & ADVANTAGE (PSC MOTOR) Comfort SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20 Advantage SUPXX-A120D12 SUPXX-A240D12 SUPXX-A120D20 SUPXX-A240D20 INSTALLER / SERVICE TECHNICIAN:

More information

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE Save These Instructions For Reference ALL OLM SERIES FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED

More information

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE Save These Instructions For Reference SMO 112 FURNACES ARE AIR CONDITIONING READY! NOTICE TO HOMEOWNER THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED

More information

FEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A

FEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A (3 WIRES 120/240 60 1) MULTI POSITION Models: FEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A DNS-0981 Rev. A INSTALLER /

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. September 2016 Version 7

Installation instructions for Plenum-mounted add-on electric heaters MODEL TU. September 2016 Version 7 Installation instructions for Plenum-mounted add-on electric heaters MODEL TU September 2016 Version 7 THERMOLEC PLENUM HEATER MODEL TU BEFORE YOU START -GENERAL SAFETY AND INSTALLATION PRECAUTIONS Please

More information

Installation, Operation and Service Manual

Installation, Operation and Service Manual Installation, Operation and Service Manual KLF-100 85% + EFFICIENCY OIL FIRED LOWBOY FURNACE INSTALLATIONS MUST MEET ALL LOCAL AND FEDERAL CODES THAT MAY DIFFER FROM THIS MANUAL Please read the manual

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL Model RGAC/SGAC Self Contained Cooling/Gas Heat Supersedes: 145.24-O1 (708) Units Form 145.24-O1 (908) MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL CATEGORY III GAS HEATING/ELECTRIC

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.

More information

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION ISTAATIO AD OPERATIG ISTRUCTIOS VETIATIO FA / IGHT / IGHT IGHT READ AD SAVE THESE ISTRUCTIOS GEERA SAFETY IFORMATIO. Make sure that the electric service supply voltage is AC 0V, 60Hz.. Follow all local

More information

XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT

XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT A INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT UNIT MODEL NO. UNIT SERIAL NO. SERVICED BY: TEL. NO: CANADIAN HEAD OFFICE AND FACTORY 1401 HASTINGS

More information

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits TECHNICAL SPECIFICATIONS E2 Series Downflow, Upflow Electric Furnaces The E2 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low maintenance.

More information

Quest Power Electric Heat EHS 62 Pro

Quest Power Electric Heat EHS 62 Pro Quest DRY Power 150 Electric Heat EHS 62 Pro Read and Save These Instructions The Quest Power Electric Heat EHS 62 Pro portable, heavy duty electric heater features multiple power receptacles for connection

More information

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE). This document was created with FrameMaker 4.0.4 SIZES AVAILABLE: 024065 through 060150 EFFICIENCY: IGNITION: HEAT EXCHANGER: CONTROL BOARD: The GA1A Induced-Combustion Gas Furnace provides the efficiency

More information

ALIMENTATION 240 VAC POWER SUPPLY

ALIMENTATION 240 VAC POWER SUPPLY ALIMENTATION 240 VAC POWER SUPPLY MULTI POSITION Models: FEM10-M2301CM-B FEM15-M2301CM-B FEM18-M2301CM-B FEM20-M2301CM-B FEM23-M2301CM-B FEM20-M2301DM-B FEM23-M2301DM-B FEM27-M2301DM-B DNS-0981 Rev. A

More information

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250

More information

1022 R/T Remote Monitor

1022 R/T Remote Monitor 1022 R/T Remote Monitor INSTRUCTIONS AMC-1022R/T WITH REMOTE SENSOR OR TRANSMITTER INSTALLATION AND OPERATING INSTRUCTIONS FOR THE AMC-1022R/T UNIT IMPORTANT: Please read these installation and operating

More information

FOR EASY, FAST INSTALLATION AND FOR RESULTS

FOR EASY, FAST INSTALLATION AND FOR RESULTS Page 1 INSTALLATION & OPERATING INSTRUCTIONS FOR FEDERAL FLOOR FURNACE OFB-100 AND OFB100L UNPACK SHIPMENT CAREFULLY AND INSPECT FOR DAMAGE. ALL GOODS ARE CAREFULLY MANUFACTURED, INSPECTED, CHECKED, AND

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use

More information

USER S guide. electric furnace. This unit complies with. standards

USER S guide. electric furnace. This unit complies with. standards USER S guide SFE series electric furnace Replacement component list included This unit complies with the CSA and UL standards SYSTÈME QUALITÉ CERTIFIÉ - REGISTERED QUALITY SYSTEM This unit is approved

More information

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial

More information

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES FORM NO. G11-489 REV. 2 Supersedes Form No. G11-489 Rev. 1 GAS FURNACES RGPR- SERIES ECM Equipped Models with Input Rates from 50,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single Phase [15 to 37 kw] (U.S.

More information

Installation Instructions

Installation Instructions P700U -21NHP Base Non -Programmable Thermostats Installation Instructions Designed and Assembled in the USA. US patents: US20060165149 A1, USD578026 SI, US6205041 B1 A14005 Base Non---Programmable Thermostat

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace WARNING Improper installation, adjustment, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance

More information

Quest Power Electric Heat EHS 31 Pro

Quest Power Electric Heat EHS 31 Pro Quest DRY Power 150 Electric Heat EHS 31 Pro Read and Save These Instructions The Power Electric Heat EHS 31 Pro portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed

More information

Owner s Manual Phoenix FireBird

Owner s Manual Phoenix FireBird 4201 Lien Rd Madison, WI 53704 Owner s Manual Phoenix FireBird Installation, Operation and Service Instructions Important Instructions Read and Save These Instructions The FireBird portable, heavy duty

More information

INSTRUCTIONS! DO NOT DISCARD!

INSTRUCTIONS! DO NOT DISCARD! INSTRUCTIONS! DO NOT DISCARD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components d N0417 Page 1 of 10 INSTALLATION INSTRUCTIONS CAUTION

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT MASSAGE TO INSTALLER: "The United States Environmental Protection Agency ("EPA") has issued various regulations regarding the

More information

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax AllStyle Coil Company, LP 7037 Brittmore Houston, TX 77041 Phone 713-466-6333 Fax 713-466-6363 April 2005 VL / VLX Series Air Handler VL / VLX Series Air Handlers Installation Operation Maintenance The

More information

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.

More information

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input Product Data 58EFA Horizontal Gas Furnace 50,000 125,000 Btuh Input GAS SUPPLY MANUAL SHUTOFF VALVE SEDIMENT TRAP UNION Carrier presents the 58EFA, a dedicated horizontal gas furnace that excels in the

More information

Model SWAC Self Contained Cooling/ Hot Water Heating Units UNIT MODEL SWAC - R22 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Model SWAC Self Contained Cooling/ Hot Water Heating Units UNIT MODEL SWAC - R22 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Model SWAC Self Contained Cooling/ Hot Water Heating Units Supersedes: 145.26-IOM1 (708) Form 145.26-IOM1 (908) UNIT MODEL SWAC - R22 Hot Water Heating / Electric Cooling INSTALLATION, OPERATION & MAINTENANCE

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

SUBMITTAL SCHEDULE & DATA

SUBMITTAL SCHEDULE & DATA SUBMITTAL SCHEDULE & DATA Gas- and Oil-Fired Unit Heaters, Infrared Heaters, and Indoor Duct Furnaces Job Name: Date: 10/31/2016 Location: Engineer: Submitted by: Jeff Musto Architect: Contractor: Model

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ROOFTOP UNITS SIZES FROM 600 CFM TO 9,000 CFM I/O MANUAL Horizontal/Modular/Vertical/Rooftop AHU 2011pg. 1 INTRODUCTION READ THE ENTIRE INSTALLATION, OPERATION

More information

INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE

INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE COMFORT & ADVANTAGE (PSC MOTOR) MULTI-POSITION Models: COMFORT SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20 ADVANTAGE SUPXX-A120D12

More information

Service Parts, Kits and Accessories

Service Parts, Kits and Accessories The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. GSC-497 REV. 2 Supersedes Form No. GSC-497 Rev. 1 GF901U SERIES Models with Input Rates 45,000, 60,000, 105,000 & 120,000 BTU/HR [13.19, 17.58, 30.77, & 35.17 kw] (All Models 90% A.F.U.E. or Above)

More information

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL FORM NO. G11-499 Supersedes Form No. G11-499 GAS FURNACES RGFE- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.16 kw] (All Models 92% A.F.U.E. or Above) Equipped with Comfort

More information

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater

More information

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount. Recessed Mount Ceiling Mounted Fan Forced SERIES 500 Surface Mount Installation & Maintenance Instructions Dear Owner, Congratulations Thank you for purchasing this new heater manufactured by Marley Engineered

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-496 REV. 4 Supersedes Form No. G11-496 Rev. 3 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES SIZES AVAILABLE: 024045 through 060155 EFFICIENCY: The GB1AAV Induced-Combustion Gas Furnace provides the efficiency customers want with 80% Annual Fuel Utilization Efficiency (AFUE). IGNITION: The field-proven

More information

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS E3EB-xxx-H Series Downflow, Upflow Electric Furnaces The E3 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and

More information

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR FORM NO. G22-506 Supersedes Form No. G22-506 Rev. 1 GAS FURNACES RGLT- SERIES Models with Input Rates from 75,000 to 125,000 BTU/HR [22 to 37 kw] (U.S. & Canadian Models) Annual Fuel Utilization Efficiency

More information

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS E4EB-xxx-H Series Downflow, Upflow Electric Furnaces The E4 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) FORM NO. G22-482 REV. 8 Supersedes Form No. G22-482 Rev. 7 GAS FURNACES RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above) 90 PLUS WITH DUAL COMFORT CONTROL

More information

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4

More information

Model READ / SEAD Self Contained Cooling / Electric Heating Units

Model READ / SEAD Self Contained Cooling / Electric Heating Units Model READ / SEAD Self Contained Cooling / Electric Heating Units Supersedes: 145.31-IOM1 (708) Form 145.31-IOM1 (908) UNIT MODELS READ / SEAD - R410A ELECTRIC HEATING / ELECTRIC COOLING INSTALLATION,

More information

MODELS B1PA024, 030 AND 036

MODELS B1PA024, 030 AND 036 STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat

More information

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable LOW --- BOY OIL FURNACE INPUT CAPACITIES: 77,000 THRU 154,000 BTUH Product Data THE LATEST IN OIL FURNACE TECHNOLOGY A10232 The models OBL and OVL combine high efficiency and quiet operation with oil heating

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. F 2018 nvent P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4

More information

MS-600 DESICCANT DEHUMIDIFIER

MS-600 DESICCANT DEHUMIDIFIER MS-600 DESICCANT DEHUMIDIFIER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 5931 Ford Court Brighton, MI 48116 Phone: 810-229-7900 Fax: 810-229-7908 E-Mail: Sales@cdims.com Web-site: www.cdims.com

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS REVOLUTION L-360-CD & L-420-CD SERIES If for any reason, you cannot follow these instructions, FOR ANY REASON WHATSOEVER, just return the product to your dealer,

More information

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N T-SERIES Air Conditioner T62 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-239 TABLE OF CONTENTS RECEIVING THE AIR CONDITIONER... 3 HANDLING AND TESTING THE AIR CONDITIONER... 3 INSTALLATION INSTRUCTIONS...

More information

Owner s Manual Phoenix Aquadry TX 200

Owner s Manual Phoenix Aquadry TX 200 4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix Aquadry TX 200 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Aquadry TX 200, like the TX 80, can be

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS Table of Contents Models BTU & BRU General Information 3 Performance and Dimensional Data 4, 5 Model Number Description 6 Model BST General Information 7 Performance

More information

Installation & Maintenance Instructions

Installation & Maintenance Instructions PRH Series Plenum Heaters Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise

More information

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement. AHF / AHK SERIES AIR HANDLING UNITS INSTALLATION GUIDE GENERAL The AHF / AHK series is designed for horizontal recessed installations in a furred down area, above a suspended ceiling or recessed in the

More information

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION: Owner s Manual Model G70 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this heater. For your safety, always comply with all warnings and safety instructions

More information

Electric Duct Heaters

Electric Duct Heaters Electric Duct Heaters 12541_Tutco_Catalog.indd 1 3/4/11 8:46:01 AM TYPICAL HEATER CONSTRUCTION TUTCO, the world s largest supplier of open coil heating elements, produces the highest quality products in

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MOBILE HEATED DISH CABINET TM HDC Series Stores, heats, and holds dishes. CONGRATULATIONS... HDC-252-I Heated model shown with flip back top opened....and thank you for purchasing

More information

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Rheem Classic Series Downflow/ Horizontal Gas Furnaces Gas Furnaces Rheem Classic Series Downflow/ Horizontal Gas Furnaces RGTC- Series Up to 95% A.F.U.E. Input Rates from 45 to 105 kbtu [13.19 to 30.77 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE

INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL: ELECTRIC FURNACE COMFORT & ADVANTAGE (PSC MOTOR) MULTI-POSITION Models: COMFORT SUPXX-C120D12 SUPXX-C240D12 SUPXX-C120D20 SUPXX-C240D20 ADVANTAGE SUPXX-A120D12

More information

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25

More information

Quest PowerHeat HFC 100 Pro

Quest PowerHeat HFC 100 Pro Quest PowerHeat HFC 100 Pro Installation, Operation and Maintenance Instructions Read and Save These Instructions This manual is provided to acquaint you with the portable fan coil so that installation,

More information

Gas-Fired Indoor and Outdoor Duct Furnaces

Gas-Fired Indoor and Outdoor Duct Furnaces July, 2008 Gas-Fired Indoor and Outdoor Duct Furnaces INDOOR GRAVITY VENTED DFG, DBG, DCG INDOOR SEPARATED COMBUSTION DFS, DBS, DCS OUTDOOR GRAVITY AND POWER EXHAUSTED H Series table of contents A complete

More information

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price Product Data 58PAV Energy-Efficient Induced-Combustion Upflow Furnace Input Capacities: 45,000 thru 155,000 Btuh 80% AFUE At Budget Price Carrier provides an 80 percent Annual Fuel Utilization Efficiency

More information

MICROWAVE OVEN SERVICE MANUAL

MICROWAVE OVEN SERVICE MANUAL MICROWAVE OVE SERVICE MAUA MODE: MG-553MD/MG-553MDS CAUTIO BEFORE SERVICIG THE UIT, READ THE SAFETY PRECAUTIOS I THIS MAUA. SPECIFICATIOS ITEM MODE Power Requirement Power Output Microwave Frequency Magnetron

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...

More information

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER Keep This Manual With Heat Exchanger Find additional information on this model at kooltronic.com or use the Technical Documents QR code below. Technical Documents KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

More information

Installation Instructions

Installation Instructions Installation Instructions B5BV Series Electric Furnaces For HUD approved installations in manufactured homes and modular homes These instructions are intended to assist qualified individuals experienced

More information

INFRARED RADIANT HEATERS

INFRARED RADIANT HEATERS IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design

More information

Single Package Vertical R-410A A/C & H.P. UNIT MODELS VPC-B, VPP-B, & VPH-B INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Single Package Vertical R-410A A/C & H.P. UNIT MODELS VPC-B, VPP-B, & VPH-B INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Single Package Vertical R-410A A/C & H.P. Supersedes: 145.19-IOM1 (708) Form 145.19-IOM1 (908) UNIT MODELS VPC-B, VPP-B, & VPH-B INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Unit Model VPC-B R-410A

More information

RE9X Series Downflow, Upflow Electric Furnaces

RE9X Series Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS RE9X Series Downflow, Upflow Electric Furnaces The RE9X Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and low

More information

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation Product Data 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces 58BLA Low-Boy AN INDEPENDENT LABORATORY TESTING FOR PUBLIC SAFETY ama 58BMA 3-Way Multipoise 58BTA Upflow/Horizontal Copyright 1996 Carrier Corporation

More information

Single Package Vertical R-22 A/C & HP UNIT MODELS VPC, VPP, & VPH INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Single Package Vertical R-22 A/C & HP UNIT MODELS VPC, VPP, & VPH INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Single Package Vertical R-22 A/C & HP Supersedes: 145.20-IOM1 (708) Form 145.20-IOM1 (908) UNIT MODELS VPC, VPP, & VPH INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS Unit Model VPC R-22 Single Packaged

More information

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC WIRING DIAGRAMS R410A MODELS 2OAC/2OACH PAC CAC PWC OWC WIRING 02172017 TABLE OF CONTENTS PAGE 2OACH Deluxe Portable Air-cooled Heat Pump Electronic Controller... 2-3 Piping Schematic... 4 Single Phase

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS MODELS 170F, 174F & 178F FAN FORCED WALL HEATERS FINISH ASSEMBLIES FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING READ AND SAVE THESE INSTRUCTIONS IMPORTANT INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE INSTALLING

More information

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-498 REV. 5 Supersedes Form No. G11-498 Rev. 4 RGTS- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY DOWNF/

More information

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES FORM NO. G11-497 REV. 4 Supersedes Form No. G11-497 Rev. 3 RGRS/RGRT- SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to 35.17 kw] (All Models 90% A.F.U.E. or Above) 90 EFFICIENCY UPF

More information