DLFSCA and DLFLCA Cassette Ductless System Sizes 9 to 48 INDUSTRY LEADING FEATURES / BENEFITS

Size: px
Start display at page:

Download "DLFSCA and DLFLCA Cassette Ductless System Sizes 9 to 48 INDUSTRY LEADING FEATURES / BENEFITS"

Transcription

1 DLFA and DLFLA assette Ductless ystem izes 9 to 8 NOTE: Image for illustration purposes only. Actual model may differ slightly. INDUTRY LEADING FEATURE / BENEFIT A PERFET BALANE BETWEEN BUDGET LIIT, ENERGY AVING AND OFORT. The ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The in ceiling cassette fan coils are ideal for retrofit or modernization projects where a false ceiling is available. This selection of fan coils permits inexpensive and creative solutions to design problems such as: TABLE OF TENT PAGE ODEL NUBER NOENLATURE... 3 TANDARD FEATURE AND AEORIE... DIENI... 5 LEARANE... 6 PEIFIATI... 7 OPATIBILITY... 7 APPLIATI DATA... 8 WIRING... 9 WIRING DIAGRA GUIDE PEIFIATI... 1 Add ons to current space (an office or family room addition) pecial space requirements When changes in the load cannot be handled by the existing system When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork Historical renovations or any application where preserving the look of the original structure is essential. The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels. pecifications subject to change without notice.

2 LOW OUND LEVEL When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. EURE OPERATI If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather. FAT INTALLATI This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping needs to run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ductless systems the equipment of choice, especially in retrofit situations. IPLE ERVIING AND AINTENANE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. oils can be cleaned quickly from inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy to use cleanable filters. In addition, these cassette systems have extensive self diagnostics to assist in troubleshooting. BUILT IN RELIABILITY Ductless system indoor and outdoor units are designed to provide years of trouble free operation. The in ceiling cassette units include protection against freeze up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over current protection and the high temperature protection. INDIVIDUAL ROO OFORT aximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year round comfort can be provided with heat pumps. EOIAL OPERATI The ductless system design allows individual room heating or cooling when required. There is no need to run large supply air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted moving air through ducts. EAY TO UE TROL The in ceiling cassette has microprocessor based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between user and the unit. FATORY INTALLED DENATE LIFT PUP ustomizing these ductless systems to your application is easily accomplished. The factory installed condensate lift pump on the cassette fan coil unit provides installation flexibility. OPTIAL WIRED TROLLER AGENY LITING All systems are listed with AHRI (Air onditioning, Heating & Refrigeration Institute), and ETL. 2 pecifications subject to change without notice

3 ODEL NUBER NOENLATURE INDOOR UNIT DLF A H 09 X A K DLF = FAN OIL UNIT VOLTAGE K = 208/ & L = ODEL A = VARIATI INDOOR FAN OIL TYPE = AETTE AJOR ERIE INDOOR FAN OIL TYPE H = HEAT PUP X = NOT UED NOINAL APAITY 09-3/ T 12-1 T 2-2 T T 36-3 T 8 - T Use of the AHRI ertified T ark indicates a manufacturer s participation in the program For verification of certification for individual products, go to pecifications subject to change without notice

4 TANDARD FEATURE AND AEORIE Ease Of Installation ounting Brackets Low Voltage ontrols omfort Features icroprocessor ontrols Wired Remote ontrol Wireless Remote ontrol Automatic Horizontal Air weep Wi-Fi Remote ontrol A Air Direction ontrol Auto Restart Function old Blow Protection On Heat Pumps Freeze Protection ode On Heat Pumps Turbo ode ilence ode Auto hangeover On Heat Pumps Follow e Energy aving Features leep ode top/tart Timer 6 F Heating ode (Heating etback) afety And Reliability Indoor oil Freeze Protection Indoor oil High Temp Protection in Heating ode Aluminum Golden Hydrophilic pre-coated fins Ease Of ervice And aintenance leanable Filters Diagnostics Liquid Line Pressure Taps ondensate Drain Adaptor Application Flexibility ondensate Lift Pump Legend tandard A Accessory AEORIE ORDERING NO. DERIPTI FOR ODEL KAN0101AAA Wired Remote ontrol with Timer Function All izes KAN0501AAA Wired Remote ontrol 7 day Programmable All izes KALG0101AAA Grille/eiling Panel 2ft x 2 ft IZE KALG0201AAA Grille/eiling Panel 3ft x 3 ft IZE 2-8 KAIF001AAA Wi-Fi Kit All izes INDOOR UNIT AEORIE Grille To maximize shipping efficiency, the grille for the in ceiling cassette is set up as an accessory. NOTE: Grille is required. A pecifications subject to change without notice

5 DIENI Liquid side Gas side Body Drain hole ( for ervice ) Wiring connection port E-parts box 22.(570) 21.6(55) -crew hole (for install panel) -install hanger 21.6(55) 22.(570) 10.2(260) 0.98(25) Drain pipe 2.56(65) Outside Air Intake 2.95(75) Wiring connection port 1.65(2) 1.65(2) Panel 25.7(67) 1.73() 1.73() 1.73() 25.7(67) Fig. 1 - Indoor Unit 1.97(50) UNIT IZE Height Width Depth Height Width Depth Weight Gross Weight Net in (mm) In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg) 9K 12K 18K 2K 36K 8K Body Panel Body Panel Body Panel Body Panel Body Panel Body Panel DIENI (260) (50) (260) (50) (260) (50) (205) (55) (25) (55) (287) (55) (570) (67) (570) (67) (570) (67) (80) (950) (80) (950) (80) (950) 22. (570) 11.2 (290) (655) (655) 1.88 (19) (16) 25.7 (67).8 (123) (715) (715) 9.92 (.5) 5.51 (2.5) 22. (570) 11.2 (290) (655) (655) 1.88 (19) (16) 25.7 (67).8 (123) (715) (715) 9.92 (.5) 5.51 (2.5) 22. (570) 25.7 (67) PAKAGING (290) (123) (655) (715) (655) (715) (21) (.5) (18) (2.5) (80) 8.5 (217) 35.3 (900) 35.3 (900) 5.23 (2.6) 6.3 (21) 37. (950) 3.5 (90) 0.75 (1035) 0.75 (1035) 17.6 (8) (5) (80) (257) 35.3 (900) 35.3 (900) 66.1 (30) 58.2 (26.) 37. (950) 3.5 (90) 0.75 (1035) 0.75 (1035) 17.6 (8) (5) (80) 11.5 (292) 35.3 (900) 35.3 (900) (32.9) (28.7) 37. (950) 3.5 (90) 0.75 (1035) 0.75 (1035) 17.6 (8) (5) pecifications subject to change without notice

6 LEARANE Fig. 2 - Indoor Unit learance 6 pecifications subject to change without notice

7 PEIFIATI Heat Pump ystem ize 9K 12K 18K 2K 36K 8K Indoor odel DLFAH09XAK DLFAH12XAK DLFAH18XAK DLFAH2XAK DLFLAH36XAK DLFLAH8XAK Voltage, Phase, ycle V/Ph/Hz 208/ / / / / / Electrical Power upply Indoor unit powered from outdoor unit A A Wireless Remote ontroller ( F/ onvertible) tandard tandard tandard tandard tandard tandard ontrols Wired Remote ontroller ( F/ onvertible) Optional Optional Optional Optional tandard tandard ooling Indoor DB in -ax F ( ) 62~90 (17~32) 62~90 (17~32) 62~90 (17~32) 62~90 (17~32) 63~90 (17~32) 63~90 (17~32) Operating Range Heating Indoor DB in -ax F ( ) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) 32~86 (0~30) Pipe onnection ize - Liquid in (mm) 1/ (6.35) 1/ (6.35) 1/ (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) Piping Pipe onnection ize - uction in (mm) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7) 5/8 (16) 5/8 (16) 5/8 (16) Face Area q. Ft No. Rows Indoor oil Fins per inch ircuits Body Unit Width in (mm) 22. (570) 22. (570) 22. (570) (80) (80) (80) Body Unit Height in (mm) 10.2 (260) 10.2 (260) 10.2 (260) 8.07 (205) 9.65 (25) 11.3 (287) Body Unit Depth in (mm) 22. (570) 22. (570) 22. (570) (80) (80) (80) Body Net Weight lbs (kg) (16) (16) (18) 6.3 (21) 58.2 (26.) (28.7) Grille Unit Width in (mm) 25.7 (67) 25.7 (67) 25.7 (67) 37. (950) 37. (950) 37. (950) Grille Unit Height in (mm) 1.97 (50) 1.97 (50) 1.97 (50) 2.17 (55) 2.17 (55) 2.17 (55) Grille Unit Depth in (mm) 25.7 (67) 25.7 (67) 25.7 (67) 37. (950) 37. (950) 37. (950) Indoor Grille Net Weight lbs (kg) 5.51 (2.5) 5.51 (2.5) 5.51 (2.5) (5) (5) (5) Number of Fan peeds Airflow (lowest to highest) F 270/306/ /296/350 39/85/ /761/ /958/ /1030/1177 ound Pressure (lowest to highest) db(a) 33/35/38 27/3/2 33/0/6.5 7/50/52 9/52/55 9/52/55 Air throw Data ft (m) 23 (7) 23 (7) 30 (9) 30 (9) 30 (9) 30 (9) oisture removal Pint/h (L/h) 1.58 (0.75) 2.88 (1.366).26 (2.02) 5.22 (2.7) 8.53 (.0) 13.5 (6.39) Field Drain Pipe ize O.D. in (mm) 1 (25.) 1 (25.) 1 (25.) 1 (25.) 1 (25.) 1 (25.) Performance may vary based on the outdoor unit to which it is matched. ee the compatible outdoor unit's product data for performance data. OPATIBILITY Indoor Unit DLFAH09XAK DLFAH12XAK DLFAH18XAK DLFAH2XAK DLFLAH36XAK DLFLAH8XAK Outdoor Unit ingle Zone DLRAH09AAK DLRAH12AAK DLRAH18AAK DLRAH2AAK DLLRAH36AAK DLLRAH8AAK DLRAH18BAK DLRAH27AK Outdoor Unit ulti-zone DLRAH36DAK DLRAH8EAK pecifications subject to change without notice

8 APPLIATI DATA UNIT ELETI elect equipment to either match or handle slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part load operation. For units used in spaces with high sensible loads, base equipment selection on the unit sensible load, not on the total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing the equipment. UNIT OUNTING (INDOOR) Refer to unit Installation Instructions for further details. Unit leveling For reliable operation, units should be level in all planes. Align and level the unit by adjusting the nuts and lock nuts on the threaded hangers. learance A minimum of 12in (30.8mm) of clearance is required in the false ceiling. Unit location Placing the unit in the center of the room provides the best air circulation and comfort. The unit return and discharge should not be obstructed by anything that may cause unit short cycling or air recirculation. Installation Template Fan coil units are supplied with a cardboard template to help match the position of the hangers, refrigerant lines, condensate drain pipe, and power supply cable. UNIT OUNTING (OUTDOOR) Refer to the unit s Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. For those applications, contact your ductless representative. YTE OPERATING DITI OPERATING RANGE in / ax F ( ) ooling Heating Indoor DB 63 / 90 (17 / 32) 32 / 86 (0 / 30) Indoor WB 59 / 8 (15 / 29) DRAIN NETI Install drains to meet local sanitation codes. The in ceiling cassette is supplied with a condensate lift pump that is capable of lifting the water 29.5in (750mm) above the top of the unit. A downward sloped condensate drain pipe can be used to dispose of water. REFRIGERANT LINE General refrigerant line sizing: 1. The outdoor units are shipped with a full charge of R10A refrigerant. 2. Refrigerant lines should not be buried in the ground. If it is necessary to bury the lines, not more than 36in (91mm) should be buried. Provide a minimum 6in (152mm) vertical rise to the service valves to prevent refrigerant migration. 3. Both lines must be insulated. Use a minimum of 1/2in (12.7mm) thick insulation. losed cell insulation is recommended in all long line applications.. pecial consideration should be given to isolating interconnecting tubing from the building structure. Isolate the tubing so that vibration or noise is not transmitted into the structure. UPPORT Adequate support must be provided to support the weight of all fan coils. Refer to the Physical Data section for fan coil weights and the base unit dimensional drawings for the location of the mounting brackets. 8 pecifications subject to change without notice

9 WIRING All wires must be sized per NE (National Electrical ode) or E (anadian Electrical ode) and local codes. Use Electrical Data table A (minimum circuit amps) and OP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Recommended onnection ethod for Power and ommunication Wiring: The main power is supplied to the outdoor unit. The field supplied 1/3 stranded wire with ground with a 600 volt insulation rating, power/communication wiring from the outdoor unit to indoor unit consists of four () wires and provides the power for the indoor unit. Two wires are line voltage A power, one is communication wiring () and the other is a ground wire. Wiring between indoor and outdoor unit is polarity sensitive. The use of BX wire is NOT recommended. If installed in a high Electromagnetic field (EF) area and communication issues exists, a 1/2 stranded shielded wire can be used to replace L2 and () between outdoor unit and indoor unit landing the shield onto ground in the outdoor unit only.! AUTI EQUIPENT DAAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Wires should be sized based on NE and local codes. TROL YTE The indoor unit is equipped with a microprocessor control to perform two functions: 1. Provide safety for the system 2. ontrol the system and provide optimum levels of comfort and efficiency. The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor too) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. WIRELE REOTE TROL Fig. 3 - Wireless Remote ontrol 1. A wireless remote control is supplied for system operation of all in ceiling cassette units. 2. Each battery operated wireless (infrared) remote control may be used to control more than one unit.! AUTI EQUIPENT DAAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Be sure to comply with local codes while running wire from the indoor unit to the outdoor unit. Every wire must be connected firmly. Loose wiring may cause the terminal to overheat or result in unit malfunction. A fire hazard may also exist. Ensure all wiring is tightly connected. No wire should touch the refrigerant tubing, compressor or any moving parts. Disconnecting means must be provided and shall be located within sight and readily accessible from the air conditioner. onnecting cable with conduit shall be routed through the hole in the conduit panel. pecifications subject to change without notice

10 WIRED REOTE TROL (OPTIAL) Part Numbers (P/N) KAN0101AAA (Timer Function) KAN0501AAA (7 Day Programmable) 1. Optional wired remote controller used for system operation of all in ceiling cassette units. NOTE: Extension wire available through RD (KAN0101AAA Part Number: ; KAN0501AAA Part Number: ). 2. Kit includes a wired remote controller and a connecting cable. 3. onnect the wire terminal between the remote controller and the indoor unit.. Display in F or and temperature increments every 1 F or every 1. Fig. - KAN0101AAA (Timer Function) Fig. 5 - KAN0501AAA (7 Day Programmable) AIR FLOW DATA INDOOR (F) YTE IZE 9K 12K 18K 2K 36K 8K (208/230) (208/230) (208/230) (208/230) (208/230) (208/230) HIGH EDIU LOW AIR THROW DATA UNIT APAITY AX. APROXIATE AIR THROW ft. (m) APROXIATE AIR THROW RANGE ft. (m) 9K 23 (7) 11 (3.5) ~ 23 (7) 12K 23 (7) 11 (3.5) ~ 23 (7) 18K 30 (9) 13 () ~ 30 (9) 2K 30 (9) 13 () ~ 30 (9) 36K 30 (9) 13 () ~ 30 (9) 8K 30 (9) 13 () ~ 30 (9) OITURE REOVAL YTE IZE 9K 12K 18K 2K 36K 8K Dehumidifying Volume L/h Dehumidifying Volume PINT/h OUND PREURE YTE IZE 9K 12K 18K 2K 36K 8K ooling Operation Indoor ound Pressure dba (L//H) 33/35/38 27/3/2 33/0/6.5 7/50/52 9/52/55 9/52/55 Heating Operation Indoor ound Pressure dba (L//H) 31/3/37 27/3/1 32/39/5 5.7/8.8/ /52/ /52.8/ pecifications subject to change without notice

11 OUND PREURE TETING ETHOD Unit Outlet Indoor Unit 3.2 ft (1m) x icrophone Fig. 6 - ound Pressure Testing ethod 3.2 ft (1m) ELETRIAL DATA UNIT IZE 9K OPER. VOLTAGE INDOOR FAN AX / IN* V-PH-HZ FLA HP W K AX FUE B AP 18K Refer to outdoor unit installation instructions 253 / /1/60 2K Indoor unit powered by the outdoor unit 36K K *Permissible limits of the voltage range at which the unit will operate satisfactorily. LEGEND FLA - Full Load Amps FAN AND OTOR PEIFIATI YTE IZE 9K 12K 18K 2K 36K 8K aterial AB AB AB AB AB AB Indoor Fan Type LX-322*17.5*12-7N LX-322*17.5*12-7N LX-322*17.5*12-7N LX-60*128*12-7N LX-76*160*12-7N LX-76*170*12-7N Diameter inch Height inch Indoor Fan otor Indoor Fan otor odel WZDK6-38G WZDK6-38G WZDK6-38G ZKFP ZKFP ZKFN Volts V 208/ / / / / /230 Type D D D D D D Phase FLA Insulation lass E E E E E E afe lass IPX0 IPX0 IPX0 IPX0 IPX0 IPX0 Input W Output W Range of urrent Amps 0.16±10% 0.16±10% 0.16±10% 0.332±10% 0.8±10% 1.6±10% Rated urrent Amps apacitor µf N/A Rated HP HP peed rev/min 600/520/60 680/580/ /630/ /520/50 720/630/ /800/700 Rated RP rev/min ax. Input W pecifications subject to change without notice

12 WIRING DIAGRA FUNTI OF WITH WITHFOR UNIT ADDRE ADDRE etting ADDRE etting 9 A B 9 A B 0 8 W3 WITH FOR AUTO-RETART ETTING TATE 3 0~ ~7 ODEREEBERNO_REEBER etting W6 WITH FOR TEP.OPENATI 9 A B TATE VALUE etting 9 A B E function 16~31 3 8~63 2 Anti-cold air W1FAN OTOR TOP-TE 8 WITH FOR FAN OTER TROL W2 THEN NO POWER REQUET. TATE ODE FAN OFF FAN etting W5 WITH FOR ODE-PRIOR ETTING TATE 2 setting 15 According to the EEPRO setting ODEHEATHEATOOLOOL etting Y/G Inner Driver D otor 5 TO WIRE TROLLER DIPLAY BOARD 10 N10A 3 N0 - OFF N10 ALAR P5 N23 N8 RED N16 RED D OTOR N15 JR6 DRIVER ODLE N33 N7 T2B INDOOR UNIT 2 OUTER PIPE TEP. N13 AINBOARD P PUP 2 N6 T2 N5 N3 BLAK H P1 WATER LEVEL WITH N H N1 N1 E Y X T1 P3 P2 N110 WHITE ROO TEP. BROWN BLAK X9 XP9WING Y/G 6 Y/G OTOR N3 N13 Y/G Outer Driver D otor FAN1 AP1 TO WIRE TROLLER 5 Alarm Output To omm.bus Fig. 7 - Wiring Diagram (izes 9K 2K) RED(BROWN) Remote ontrol JR6 BLUE(BLAK) YELLOW L1 L2 NEWFAN TO OUTDOOR UNIT Reactor Y/G FUNTI OF WITH WITHFOR UNIT ADDRE EN1 WITH (FOR POWER) NUBER POWER ADDRE 5 0~15 16~31 6 / etting W-1000W(5.0HP) ADDRE 32~7 8~63 A 1500W-16000W(6.0HP) etting W3 W6 9 AB 9 AB WITH TATE WITH FOR TEP.OPENATI TATE 3 3 FOR AUTO-RETART ETTING ODE REEBER NO_REEBER etting VALUE 6 2 E function etting 8 9 AB 9 AB 3 3 etting W5 Anti-cold air W2 WITH W1 FAN OTOR TOP-TE TATE 2 setting ODE 15 According to the EEPRO setting WITH TATE ODE etting ODE: AIN NO LAVE FOR FAN OTER TROL THEN NO POWER REQUET. FAN OFF FOR AIN-LAVE ETTING AIN AIN FAN Reactor Y/G LAVE RED RED FAN1 AP1 Inner Driver D otor D OTOR Y/G DRIVER ODLE Outer Driver D otor X2 XP2 TO WING BOARD 6 3 N3 Remote ontrol Alarm Output N13 X2 XP2 5 BROWN BLAK TO GO-UP-AND -DOWN BOARD JR6 5 - OFF ALAR N23 N15 JR6 N33 N16 P3 H N P2 H N66 N3 N55 E Y X To omm.bus N0 N13 N10(N10A) INDOOR UNIT AINBOARD N2 Q E P Fig. 8 - Wiring Diagram (ize 36K 8K) Ferrite bead 2 1 To OUTDOOR omm.bus RED(BROWN) N1 L1 BLUE(BLAK) L2 N1 N8 N5 10 N7 N6 P Y/G P1 X9 NEWFAN 2 POWER DIPLAY BOARD Y/G G XP9 X10 XP10 G PUP TO WIRE TROLLER 5 TO WIRE TROLLER T2B OUTER PIPE TEP. T2 BLAK IDDLE PIPE TEP. T1 WHITE ROO TEP. WATER LEVEL WITH This symbol indicates the element is optional,the actual shape shall prevail. 12 pecifications subject to change without notice

13 WIRING DIAGRA (TABLE) ODE N1 N3 P1 N5 N6 N10A N13 N1 N15 N16 N23 N33 N0 N110 INDOOR UNIT PART NAE Input: 230VA High voltage onnection of the terminal Output: 0-5VD onnection of the Output: 0V onnection of the earth Output: 1-5VD onnection of the Water level switch Output: 5VD onnection of the Room and Pipe temperature Output: 12VD onnection of the Display board Output: 220VA High voltage onnection of the Pump Output: 12VD onnection of the wing motor Output: 320VD High voltage onnection of the D Fan Output: 320VD High voltage onnection of the Reactor Output: 1-12VD onnection of the Remote switch Output: 0V onnection of the Alarm Output: 12VD onnection of the Wire controller Output: 2VD between Pin2 of N1 connection of the signal pecifications subject to change without notice

14 GUIDE PEIFIATI INDOOR IN EILING AETTE DUTLE UNIT ize Range: 3/ to Ton Nominal ooling and Heating apacity odel Number: DLFA and DLFLA PART 1 GENERAL 1.01 ystem Description Indoor, in ceiling cassette, direct expansion fan coils are matched with a heat pump outdoor unit Agency Listings Unit are rated per AHRI tandards 210/20 and listed in the AHRI directory as a matched system Delivery, torage, and Handling Units are stored and handled per the unit manufacturer s recommendations. 1.0 Warranty (For Inclusion By pecifying Engineer) PART 2 PRODUT 2.01 Equipment A. General: Indoor, direct expansion, ceiling mounted fan coil. Unit is complete with a cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and an integral temperature sensing. B. Unit abinet: abinet is constructed of zinc coated steel. Fully insulated discharge and inlet grilles are attractively styled, high impact polystyrene. Grille has hinges and can be opened to obtain access to the cleanable filters, indoor fan motor and control box.. FAN: 1. The fan is a centrifugal direct drive blower type with an air intake in the center of the unit and a discharge at the perimeter. An automatic, motor driven vertical air sweep is provided standard. Automatic motor driven louvers are provided standard and are adjustable for a 2, 3 or way discharge. 2. The air sweep operation is user selectable. D. oil: The coil is a copper tube with aluminum fins and galvanized steel tube sheets. Fins are bonded to the tubes by mechanical expansion and specially golden hydrophilic pre coated for enhanced wet ability. A drip pan under the coil has a factory installed condensate lift pump and a drain connection for a hose attachment to remove condensate. E. otors: otors are open drip proof, permanently lubricated ball bearing with inherent overload protection. Fan motors are 7 speed. F. ontrols: ontrols consist of a microprocessor based control system which controls the space temperature, determines the optimum fan speed, and runs self diagnostics. The temperature control range is 62 F to 86 F (17 to 30 ) in increments of 1 F or 1, and has a 6 F Heating ode (Heating etback). The wireless remote controller, has the ability to act as the temperature sensing location for room comfort. The unit shall have the following functions as a minimum: 1. An automatic restart after a power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 2 hour timer cycle for the system s Auto tart/top. 3. Temperature sensing controls sense the return air temperature.. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Automatic air sweep control to provide on or off activation of air sweep louvers. 7. Dehumidification mode, which provides increased latent removal capability by modulating system operation and set point temperature. 8. A fan only operation to provide room air circulation when no cooling is required. 9. Diagnostics to provide continuous checks of the unit operation and warn of possible malfunctions. Any error messages are displayed at the unit. 10. The fan speed control is user selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes. 11. Automatic heating to cooling changeover in the heat pump mode. ontrol includes deadband to prevent rapid mode cycling between heating and cooling. 12. Indoor coil high temperature protection is provided to detect excessive indoor discharge temperature when unit is in the heat pump mode. G. Filters: The unit has a filter track with factory supplied cleanable filters. H. Electrical Requirements: The indoor fan motor operates on V on model sizes 09 8, as specified. Power is supplied from the outdoor unit. I. Operating haracteristics: The system has a minimum EER (easonal Energy Efficiency Ratio) and HPF at AHRI conditions, as listed on the specifications table. J. Refrigerant Lines: All units should have refrigerant lines that can be oriented to connect from the left, right or back of unit. Both refrigerant lines must be insulated. opyright 2018 International omfort Products NA 1025 obb Place Blvd NW Kennesaw, GA pecifications subject to change without notice

INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS. DLFSDA and DLFLDA Ducted Style Ductless System Sizes 09 to 58

INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS. DLFSDA and DLFLDA Ducted Style Ductless System Sizes 09 to 58 DLFDA and DLFLDA Ducted tyle Ductless ystem izes 9 to 5 INDUTRY LEADING FEATURE / BENEFIT NOTE: Images for illustration purposes only. Actual models may be slightly different. TABLE OF TENT PAGE MODEL

More information

Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS

Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS 0MBDQ Ducted lim Ductless ystem izes 09 to 58 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFET BALANE BETWEEN BUDGET LIMIT, ENERGY AVING AND OMFORT. The 0MBDQ series ducted slim ductless systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36 40AQ High Wall Ductless ystem izes 09 to 36 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIIT, ENERGY AVING AND COFORT. The 40AQ series ductless split systems are a matched

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 619PB HIGH WALL DUCTLE YTE IZE 09 TO 36 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIIT, ENERGY AVING AND COFORT. The 619PB series ductless systems are a matched combination

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 40MB*D Ducted tyle Ductless ystem izes 09 to 48 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MB*D series ducted style ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 40MBFQ Floor Console Ductless ystem izes 09 to 12 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MBFQ series ductless system are

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 0MHH High Wall Ductless ystem izes 09 to 2 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 0MHH series ductless systems are a matched

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36 38MA*R Outdoor Unit ingle Zone Ductless ystem izes 09 to 36 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38MA*R series ductless systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MBDQ Ducted tyle Ductless ystem izes to Product Data INDUTRY LEADING EATURE / BENEIT A PERET BALANE BETWEEN BUDGET LIMIT, ENERGY AVING AND OMORT. The MBDQ series ducted style ductless systems are a matched

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18 40MB*C / 38MAQ Cassette Ductless plit ystem izes 09 to 18 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40MB*C series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18 40MB*C / 38MAQ Cassette Ductless plit ystem izes 09 to 18 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40MB*C series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free plit ystem izes 009 to 024 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38/40MVC(Q) series duct-free

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHRB Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHRB Outdoor Unit Single Zone Ductless System Sizes 09 to 24 38MHRB Outdoor Unit ingle Zone Ductless ystem izes 09 to 24 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38MHRB series ductless systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12 40MB*F / 38MAQ Floor Console Ductless plit ystem izes 09 to 12 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MBF/38MAQ series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12 40MB*F / 38MAQ Floor Console Ductless plit ystem izes 09 to 12 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40MBF series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MBQ series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 38MPRA Outdoor Unit ingle Zone Ductless ystem izes 09 to 12 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The ductless systems are a matched

More information

Product Data. DLCERA Outdoor Unit Single Zone Ductless System Sizes 09 to 24 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. DLCERA Outdoor Unit Single Zone Ductless System Sizes 09 to 24 INDUSTRY LEADING FEATURES / BENEFITS DLCERA Outdoor Unit ingle Zone Ductless ystem izes 09 to 24 Product Data INDUTRY LEADING FEATURE / BENEFIT NOTE: Images are for illustration purposes only. Actual models may differ slightly. TABLE OF CONTENT

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ / 38MAQ High- Wall Ductless Split System Sizes 09 to 30

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ / 38MAQ High- Wall Ductless Split System Sizes 09 to 30 40MAQ / 38MAQ High- Wall Ductless plit ystem izes 09 to 30 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40MAQ series ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 38MHR Outdoor Unit ingle Zone Ductless ystem izes 09 to 24 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38MHR series ductless systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High- Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High- Wall Ductless Split System Sizes 09 to 18 40GRQ / 38GRQ High- Wall Ductless plit ystem izes 09 to 18 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40GRQ series ductless

More information

PERFORMANCE DATA Model Numbers Cooling High Heating 47 F Low Heating 17 F

PERFORMANCE DATA Model Numbers Cooling High Heating 47 F Low Heating 17 F ENVIRONMENTALLY OUND REFRIGERANT DLC4(A/H)6 Outdoor DLF4(A/H)6 Indoor Product pecifications DUCTLE HIGH WALL PLIT YTEM, R 410A Efficient 16 EER Air Conditioners and Up to 8.6 HPF Heat Pumps 3/4 thru 2

More information

Product Data. 38GVM / 40GVM Multi---Split High---Wall Ductless Split System 38GVM --- Size 18k, 24k, 30k, 36k and 42k 40GVM --- Size 9k, 12k, and 18k

Product Data. 38GVM / 40GVM Multi---Split High---Wall Ductless Split System 38GVM --- Size 18k, 24k, 30k, 36k and 42k 40GVM --- Size 9k, 12k, and 18k 38GVM / 40GVM Multi---plit High---Wall Ductless plit ystem 38GVM --- ize 18k, 24k, 30k, 36k and 42k 40GVM --- ize 9k, 12k, and 18k Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 40MKCF / 24AHA4 / 124AN 40MKQF / 25HHA4 / 224AN Under Ceiling/Floor Console Ductless ystem izes 18 to 54 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING

More information

Product Data. 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless Split System Size 18K, 24K, 30K, 36K, 42K, 48K and 56k

Product Data. 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless Split System Size 18K, 24K, 30K, 36K, 42K, 48K and 56k 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless plit ystem ize 18K, 24K, 30K, 36K, 42K, 48K and 56k Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 40MKCF / 24AHA4 / 124AN 40MKQF / 25HHA4 / 224AN Under Ceiling/Floor Console Ductless ystem izes 18 to 54 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING

More information

Product Data. 38GXM / 40GXM Multi---Split High---Wall Duct Free Split System 38GXM --- Size 18k, 24k, and 30k 40GXM --- Size 9k, 12k, and 18k

Product Data. 38GXM / 40GXM Multi---Split High---Wall Duct Free Split System 38GXM --- Size 18k, 24k, and 30k 40GXM --- Size 9k, 12k, and 18k 38GXM / 40GXM Multiplit HighWall Duct Free plit ystem 38GXM ize 18k, 24k, and 30k 40GXM ize 9k, 12k, and 18k Product Data NOTE: Read the entire instruction manual before starting the installation. INDUTRY

More information

MULTI INVERTER SERIE H6M

MULTI INVERTER SERIE H6M ULTI INVERTER SERIE H6 Service manual www.mundoclima.com Thank you very much for purchasing our products. Please read this manual carefully before installing and using the unit. L25 to L257 English TENTS

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K K

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K K 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless plit ystems ize 009K --- 036K Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38GVC(Q)/40GVC(Q)

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GXC / 38GXC 40GXQ / 38GXQ Inverter---Driven High Wall Duct---Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GXC / 38GXC 40GXQ / 38GXQ Inverter---Driven High Wall Duct---Free Split System Sizes 009 to 024 40GXC / 38GXC 40GXQ / 38GXQ InverterDriven High Wall DuctFree plit ystem izes 009 to 024 Product Data The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High Wall Ductless Split System Sizes 09 to 18 40GRQ / 38GRQ High Wall Ductless plit ystem izes 09 to 18 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 38/40GRQ series ductless split

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. DHCMA / DACMA DHQMA / DAQMA High Wall Ductless System Sizes 09 to 22

Product Data INDUSTRY LEADING FEATURES / BENEFITS. DHCMA / DACMA DHQMA / DAQMA High Wall Ductless System Sizes 09 to 22 DHCMA / DACMA DHQMA / DAQMA High Wall Ductless ystem izes 09 to 22 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The DACMA/DHCMA DAQMA/DHQMA

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48 40MB*D / 38MAQ / 38MBQ Ducted plit ystem izes 09 to 48 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MBD series ducted split systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48 40MB*D / 38MAQ / 38MBQ Ducted plit ystem izes 09 to 48 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MBD series ducted split systems

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

Product Data. High --- Wall Duct --- Free Split systems INDUSTRY LEADING FEATURES / BENEFITS

Product Data. High --- Wall Duct --- Free Split systems INDUSTRY LEADING FEATURES / BENEFITS High --- Wall Duct --- Free plit systems PA13A / PW3CA Cooling izes 009---012 PA13N / PW3CN Cooling izes 018---024 PH13A / PW3HA HP izes 009---012 PH13N / PW3HN HP izes 018---024 Product Data INDUTRY LEADING

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060 40QAC / 38HDR 40QAQ / 38QRR Ceiling---uspended Duct Free plit ystem izes 018 to 060 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38HDR(QRR)/40QAC(QAQ)

More information

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38MAQ series ductless

More information

Product Data. 38MG / 40MA / 40MB Multi- Zone Ductless Split System Size 18k, 27k, 36k and 48k INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MG / 40MA / 40MB Multi- Zone Ductless Split System Size 18k, 27k, 36k and 48k INDUSTRY LEADING FEATURES / BENEFITS 38MG / 40MA / 40MB Multi- Zone Ductless plit ystem ize 18k, 27k, 36k and 48k Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38MG / 40MA / 40MB ductless

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 0BFQ Floor Console Ductless ystem izes 09 to 8 Product Data INDURY LEADING FEAURE / BENEFI NOE: Image for illustration purposes only. Actual model may differ slightly. ABLE OF CEN PAGE ODEL NUBER NOENCLAURE...

More information

Product Data. 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 INDUSTRY LEADING FEATURES / BENEFITS 38MGQ Multi-Zone Ductless ystem izes 18, 27, 36 and 48 Product Data INDUTRY LEADING FEATURE / BENEFIT AN INEXPENIVE AND CREATIVE OLUTION TO DEIGN PROBLEM. The 38MGQ ductless inverter driven multi zone

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 58 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING... 4 DIMENSIONS... 5 CLEARANCES...

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

Installation Instructions

Installation Instructions 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Installation Instructions

Installation Instructions 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes

More information

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless System Sizes 09 to 22

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless System Sizes 09 to 22 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless ystem izes 09 to 22 TABLE OF CONTENT PAGE AFETY CONIDERATION... 1 INTRODUCTION... 1 MODEL / ERIAL NUMBER NOMENCLATURE... 2 TANDARD FEATURE AND ACCEORIE...

More information

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS

DLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32 40MKCB / 24AHA4 / 124AN 40MKQB / 25HHA4 / 224AN High---Wall Ductless plit ystem izes 18 to 32 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT.

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless Split System Sizes 09 to 36 Installation Instructions NOTE: Read the entire instruction manual before starting the installation TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 2 PARTS

More information

Installation Instructions

Installation Instructions 40MAQ High Wall Ductless System Sizes 09 to 36 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only. Actual models

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBD / 38MAQ / 38MBQ Ducted tyle Ductless plit ystem izes 09 to 48 Owner s Manual TABLE OF CONTENT PAGE A NOTE ABOUT AFETY... 2 GENERAL... 2 PART LIT... 3 DIPLAY PANEL... 4 REMOTE CONTROL... 6 REMOTE

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Installation Instructions

Installation Instructions 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... DLCMRA INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4

More information

SUPER INVERTER H6 Service manual

SUPER INVERTER H6 Service manual SUPER INVERTER H6 Service manual MUSR-H6 MUSTR-H6 MUR-H6 www.mundoclima.com Thank you very much for purchasing our products. Please read this manual carefully before installing and using the unit. L20230

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCC / 24AHA4 / 124ANS 40MKQC / 25HHA4 / 224ANS Cassette Ductless Split System Sizes 18 to 34

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCC / 24AHA4 / 124ANS 40MKQC / 25HHA4 / 224ANS Cassette Ductless Split System Sizes 18 to 34 40MKCC / 24AHA4 / 124AN 40MKQC / 25HHA4 / 224AN Cassette Ductless plit ystem izes 18 to 34 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT.

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless plit ystem izes 009 --- 024 Owner s Manual TABLE OF CONTENT PAGE AFETY PRECAUTION... 2 GENERAL... 2 INDOOR UNIT PART NAME... 3 REMOTE CONTROL PART NAME...

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

R4H4. Product Specifications

R4H4. Product Specifications R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons Product Data 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes 2to4NominalTons The 40QK Energy-Efficient In Ceiling Cassette fan coil incorporates innovative technology to provide

More information

Installation Instructions

Installation Instructions 40MBCQ Cassette Ductless System Sizes 09 to 8 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS INDOOR... 5 CLEARANCES INDOOR...

More information

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24 DLFEHA SERVICE MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 MODEL/SERIAL NUMBER NOMENCLATURES... 2 SPECIFICATIONS COOLING ONLY...

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

Installation Instructions

Installation Instructions 40MBD Ducted Style Ductless System Sizes 09 to 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr Product Data -188-05 Split System (R-10A) Air Handler for Multi Split Inverter System 9,000 to,000 BTU/Hr Ceiling Concealed Type Indoor Unit: MXD8509A10N0 MXD851A10N0 MXD8518A10N0 MXD851A10N0 MXD85A10N0

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS High --- Wall Duct --- Free plit systems PA13A / PW3CA Cooling izes 009---012 PA13N / PW3CN Cooling izes 012---024 PH13A / PW3HA HP izes 009---012 PH13N / PW3HN HP izes 012---024 Owner s Manual TABLE OF

More information

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION 619PB / 538PR HIGH-WALL DUCTLESS SPLIT SYSTEM SIZES 09 TO 30

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION 619PB / 538PR HIGH-WALL DUCTLESS SPLIT SYSTEM SIZES 09 TO 30 619PB / 538PR HIGH-WALL DUCTLE PLIT YTEM IZE 09 TO 30 TABLE OF CONTENT PAGE AFETY CONIDERATION... 1 INTRODUCTION... 1 MODEL / ERIAL NUMBER NOMENCLATURE... 2 TANDARD FEATURE AND ACCEORIE... 3 DIMENION-

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors

More information

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

R4H4. Product Specifications

R4H4. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

Installation Instructions

Installation Instructions 38MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 30, 36 and 48 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS...

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Installation Instructions

Installation Instructions 40MAQ / 38MAQ 619PB / 538PR High---Wall Ductless Split System Sizes 09 to 30 Installation Instructions TABLE OF CONTENTS PAGE PARTS LIST... 2 SAFETY CONSIDERATIONS... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS...

More information

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 12,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System Submittal Data: Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES -Compact and Quiet Design -High Efficiency DC Inverter Technology -Wireless Remote

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST Base eries Fan Coil izes 001 thru 004 Product Data AIR HANDLER TECHNOLOGY AT IT FINET The series fan coils are reliable, dependable, and a great value. These fan coils offer air handling for practical,

More information

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI 24,000 BTUH 24,000 Ceiling BTU/H Cassette Ceiling Heat Casse3e Pump Heat System Pump System Job Name Location Date Purchaser

More information

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To Submittal Data: Innovative Ductless solutions 24,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair. WALL-MOUNTED HEAT PUMPS SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) UP TO 23 SEER UP TO 11 HSPF HEATING UP TO -20 C 10 years* *See details on the back Warranty Exclusive distributor in Quebec descair.ca What

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BI Series M1200 Product Line R-410A Ultra High Efficiency Air Conditioner 24.5 SEER 2-3-4 Ton 2 M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Console Console Condenser & Mulit-Zone Satellite HDC, HDL, HDS & QR Condensers High Wall AN/BK Condensers Under Ceiling Cassette Copyright 2001

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price Product Data 58RAV High-Efficiency Downflow/Horizontal Induced-ombustion Gas Furnace Input apacities: 50,000 thru 5,000 Btuh 80% AFUE At Budget Price DOWNFLOW HORIZONTAL arrier provides an 80% Annual Fuel

More information

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Submittal Data: Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information