KITCHEN EXTRACTORS K Series
|
|
- Wilfrid Anderson
- 5 years ago
- Views:
Transcription
1 KITCHEN EXTRACTORS K Series CK-4F CK-5 CK-6F Description Construction The K Series range of centrifugal extractors are specifically designed for the extraction of moist, grease laden air and fumes from under domestic cooker canopies. The range offer powerful and quiet extract operation suitable for all domestic kitchen environments The K Series fans are easy to install and maintain due to the flexible design and configuration. A comprehensive range of accessories is offered to complete the most demanding installations. In a kitchen, the use of a cooker canopy enables the extraction of polluted air. The airflow required depends upon the canopy width and the distance between the canopy and the cooker. Within this cross-section the recommended air capture velocity, must be between.15 and.25 m/s. Range VC = Capture velocity (m/s) volume = 36 x V x SR Reference section Sr = h x l (m 2 ) This range consists on seven models with airflows ranging between 25 and 625 m 3 /h: CK-25N CK-5 CK-35N ECO-5 CK-4F CK-6F Model CK-25N is manufactured from tough injection moulded plastic. The fan incorporates a single phase 23V 5Hz, fully speed controllable motor. All models are supplied with Class II insulation and an integrated Thermal Overload Fuse to protect against overheating. Model CK-25N is manufactured from tough injection moulded plastic. The fan incorporates a single phase 23V 5Hz, fully speed controllable motor. All models are supplied with Class II insulation and an integrated Thermal Overload Fuse to protect against overheating. The CK-25N, as standard incorporates a grease collection tray with a front facia and fan impeller that can be removed for easy cleaning and maintenance (these parts can be cleaned in a dishwasher). The CK-25N model operates at an air flow performance of 25 m 3 /hr. Model CK-35N is manufactured from sheet steel with an epoxy polyester paint finish. The fan incorporates a single phase 23V 5Hz, fully speed controllable motor with a Class II insulated rating. All models are supplied with Class II insulation and an integrated Thermal Overload Fuse to protect against overheating. The CK-35N model is fitted with a metallic filter at the air inlet to prevent the build-up of grease within the fan and enclosure. All models incorporate, as standard, a grease filter; grease collection tray and a front facia and fan impeller that can be removed for easy cleaning and maintenance. The CK-35N model operates at an air flow performance of 35 m 3 /hr. Model CK-4F is manufactured from tough injection moulded plastic. The fan incorporates a single phase 23V 5Hz, fully speed controllable motor, supplied with Class II insulation and an integrated Thermal Overload Fuse to protect against overheating. The CK-4F incorporate, as standard, grease collection tray and a front facia and fan impeller that can be removed for easy cleaning and maintenance. (these parts can be cleaned in a dishwasher). In addition the CK-4F incorporates a metallic Teflon coated filter fitted to the inlet to improve filter efficiency and facilitate cleaning. The CK-4F has a maximum airflow of 36 m 3 /hr. Model CK-5 and ECO-5 casings are manufactured from sheet steel with an epoxy polyester paint finish. The front, impeller and grease tray are manufactured from tough injection moulded plastic. The fans incorporates a single phase 23V 5Hz, fully speed controllable motor. All models are supplied with Class I insulation and an integrated Thermal Overload Fuse to protect against overheating. Both models are suitable for large domestic kitchen extract applications where the removal of strong kitchen odours and large amounts of airborne grease / moisture are required. The front e, impeller and grease tray can easy be removed for cleaning. The model CK-5 can be supplied with metallic filter to replace the standard inlet guard. The CK-5 and ECO-5 models operate at an air flow performance of 48 m 3 /hr. Model CK-6F is manufactured from tough injection moulded plastic. The fan incorporates a single phase 23V 5Hz, two speed (fully speed controllable) motor. All models are supplied with Class II insulation and an integrated Thermal Overload Fuse to protect against overheating. All models incorporate a grease filter, grease collection tray, impeller and front cover that can be removed without tools for easy cleaning and maintenance (these parts can be cleaned in a dishwasher). The CK-6F incorporates a stainless steel filter fitted to the inlet to prevent the build up of grease in the fan and enclosures and to facilitate cleaning. The CK-6F models operate at an air flow performance of 625 m 3 /hr at high speed and 415 m 3 /hr at low speed. 262
2 CK-25N The CK-25N centrifugal fan has been specifically and grease laden air generated from domestic cooking areas (25 m 3 /hr capacity) The models can be installed either inside or external to a kitchen cooker canopy. They operate with very low levels of noise and offer easy cleaning and maintenance access. The versatile design also enables the fan to be used in other ventilation applications that require the extraction of moist, odour and grease laden air. Pa Pa mmwg c.d.a CK-25N Model Type Speed Maximum Voltage Max. air Sound Weight absorbed (V) flow at pressure power free air level (r.p.m.) libre (W) 5 Hz (m 3 /h) (db(a))* (kg) CK 25N , (m 3 /h) Q (m 3 /s),25,5,75 GSA-1 GRA- 7 Worm drive CAR-1 CT PER-1 W PF-6 263
3 CK-35N The CK-35N centrifugal fan has been specifically and grease laden air generated from domestic cooking areas (35 m 3 /hr capacity). The fan can be installed either inside or external to a kitchen cooker canopy. Model CK-35N incorporates a metallic grease filter to prevent the build-up of grease within the fan and enclosures. The fan operates with very low levels of noise and offers easy cleaning and maintenance access. The versatile design also enables the fan to be used in other ventilation applications that require the extraction of moist, odour and grease laden air. P Pa Pa mmwg mmce CK-35N absorbed flow level (r.p.m.) (W) 5 Hz (m 3 /h) (db(a))* (kg) CK-35N , ,25,5,75 (m 3 /h) (m 3 /s) PER-16 W CM-13 GRA-1 PF-6 Worm drive 264
4 CK-4F Centrifugal fan specifically designed to remove the smoke, odours and grease laden air generated from large domestic cooking areas, can be installed either inside or external to a kitchen cooker canopy. Fan CK-4F incorporates powerful centrifugal impellers which generate substantial pressure developments for use with long runs. CK-4F incorporates a grease filter to improve efficiency and prevent the build-up of grease within the fan and enclosures. It operates with very low levels of noise and offer easy cleaning and maintenance access. Pa mmwg c.d.a CK-4F absorbed flow level (r.p.m.) (W) 5 Hz (m 3 /h) (db(a))* (kg) CK-4F , m 3 /h Q,25,5,75,1 m 3 /s PER-16 W Exterior back draft Kitchen extract kit CK-4F GSA-1 GRA-7 Worm drive CAR-1 Back draft PF-6 The kit includes: CK-4F fan. 3m of GSA-1 flexible aluminium. 2 duct connectors CX-8/125. In-line back draught CM
5 CK-5 The CK-5 centrifugal fan has been specifically and grease laden air generated from large domestic cooking areas (48 m 3 /hr capacity). The fan can be installed either inside or external to a kitchen cooker canopy. The CK-5 can be supplied with a metallic filter to replace the plastic inlet guard (please enquire). The CK-5 fan delivers high airflow performances (48 m 3 /hr) with the minimum levels of noise (52 db) and offers easy access to parts for cleaning and maintenance. The versatile design also enables the fan to be used in other ventilation applications that require the extraction of moist, odour and grease laden air. Pa mmwg mm.c.d.a CK absorbed at flow level (r.p.m.) (W) 5 Hz (m 3 /h) (db(a))* (kg) CK , ,2,4,6,8,1,12,14,16 m 3 /h Q m 3 /s Metal inlet filter Worm drive CM-13 PER-16 W GRA-1 PF-6 266
6 ECO-5 The ECO-5 centrifugal fan has been specifically and grease laden air generated from large domestic cooking areas (48 m3/hr capacity). The fan can be installed either inside or external to a kitchen cooker canopy. The ECO-5 can be supplied with a metallic filter to replace the plastic inlet guard (please enquire). The ECO-5 fan delivers high airflow performances (48 m 3 /hr) with the minimum levels of noise (52 db) and offers easy access to parts for cleaning and maintenance. The versatile design also enables the fan to be used in other ventilation applications that require the extraction of moist, odour and grease laden air. ECO-5 Pa mmwg absorbed at flow level (r.p.m.) (W) 5 Hz (m 3 /h) (db(a))* (kg) ECO ,5 Metal inlet filter Worm drive CM-13 Kitchen Extractors ECO PER-16 W GRA-1 PF-6 267
7 CK-6F The CK-6F centrifugal fan has been specifically and grease laden air generated from large domestic cooking areas ( 625/415 m 3 /hr capacity). The fan can be installed either inside or external to a kitchen cooker canopy. The CK- 6F is supplied with a stainless steel filter to prevent the build-up of grease within the fan and enclosures. The fan incorporates two speed operation as standard and offers easy access to parts for cleaning and maintenance access. The versatile design also enables the fan to be used in other ventilation applications that require the extraction of moist, odour and grease laden air. absorbed at flow level (r.p.m.) (W) 5 Hz (m 3 /h) (db(a))* (kg) CK-6F VR VL ,7 CK-6F P (mm.c.a.) (mmwg) VR VL Q (m3/h) REGUL-2 Two speed switches COM-2 Two speed switches PER-125 W Exterior back draft GRA-1 Ø 116,5 293, Kitchen extract kit CK-6F CM-13 Back draft shuter Worm drive Roof cowls PF-6 The kit includes: CK-6F fan. 3m of flexible aluminium. 2 duct connectors. /215. Two speed position switch. REGUL
K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK
KITCHEN EXTRACTORS K Series CK-25 N CK-35 N CK-6 F Range of centrifugal extractors specifically designed for the extraction of moist, grease laden air and fume from under domestic cooker canopies. This
More informationKITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N
KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz
More informationS ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5
S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE The Quietest Extractors in the World in their Category Lp 26,5 db AXIAL FLOW FANS Series -1-1 16182 6376-2 -3 NEW Installation examples Axial fl
More informationBATHROOM EXTRACT FANS SILENT-100 Series
SILENT-1 Series Range of axial extractors with airflow rates of 95 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow
More informationJSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters
JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air Product Description The Jeven JSI-UV canopy has been designed for kitchens where a comfortable, productive and healthy indoor climate is
More informationHRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series
AKOR BP HR Series AKOR BP HR Energy recovery ventilation systems for single dwelling houses or multi-dwelling blocks, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling
More informationBurner Outputs (MJ): Rapid burner: 1 x MJ/hr Semi-rapid burners: 2 x MJ/hr Auxiliary burner: 1 x MJ/hr
Esatto Gas Pack EOG6FF Cooking Pack Electric Oven and Gas Cooktop in 1 Box Cooktop Features: 4 burners Italian made Defendi burners 304 grade stainless steel Electronic Cooktop Accessories: under-knob
More informationHRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series
AKOR ST HR Series AKOR ST HR Balanced-airflow for single dwelling houses, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling houses up to 92% of efficiency. It connects,
More informationDomestic & Commercial Fans
Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO
More informationRANGE COOKER HOOD GUIDE
RANGE COOKER HOOD GUIDE CHOOSING THE RIGHT COOKER HOOD FOR YOUR KITCHEN You ve probably spent a lot of time choosing your perfect range cooker, but what about a cooker hood? Take a look through our handy
More informationCBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS
DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS CBP 03.08-01 CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS CBP Series Description Construction Fans are not appropriate for transportation of explosion-risk
More informationFRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %
Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed
More informationORT6WXA ORT9WXA Slide-out Rangehoods
Instructions for the Use and Care and Installation of ORT6WXA ORT9WXA Slide-out Rangehoods CONTENT 1. GENERAL 2. SAFETY PRECAUTION 3.. WARNING!! 4.. INSTALLATION INSTRUCTIONS 5.. ATTENTION 6.OPERATION
More informationGUH90 90 cm Canopy Hood
User Manual for your GUH90 90 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most out of your
More informationTYPICAL KITCHEN EXTRACT SOLUTION
TYPICAL KITCHEN EXTRACT SOLUTION We have set out below a recommendation for the control of grease, smoke and odour from a fast food outlet using a char grilling process. There are varying degrees of pollution
More informationCYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.
CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB (aluminium impellers) Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel
More information(57.7) X. March 2006 PRODUCTS. ... the complete solution
(57.7) X March 26 PRODUCTS... the complete solution CONTENTS UKV FAN RANGE 2-8 Useful Technical Information 2 Non-domestic Air Change Requirements (ACH) 3 Centrifugal Tube Fans (Plastic) 4 Centrifugal
More informationWarnings, Safety Information and Guidance
EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,
More informationCONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE
CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile
More informationThe Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans
The Silent Range Pure Elegance & Tranquillity The widest range of ultra quiet silent fans The most advanced SILENT technology delivering the highest extract performance. 1 Your first choice for ventilation
More informationInstruction Manual JLCHDD601/JLCHDD901 60cm/90cm Cooker hood
Contents 3 Introduction 3 Safety is important 3 In the box 4 Safety information 4 Important safety information 4 Warnings 5 Cautions 5 Electrical information 6 Operation 6 Automatic shut-down 7 Care and
More informationCANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY
CANOPY RANGEHOOD instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY Contents Guide to the Appliance 2 Caring for the Environment 3 Safety Information and Warnings 4 Installation Instructions 6 Operation
More informationPlus Perimeter Aspiration Timer Remote control predisposition
Island Plus Perimeter Aspiration Timer Remote control predisposition Features Installation Finish Controls N. Motors Portata Max Recycling Max Noise Level Min Noise Level Total Absorption Dimensions Lighting
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationGUH52SD 52 cm GUH75 75 cm Canopy Hood
User Manual for your GUH52SD 52 cm GUH75 75 cm Canopy Hood NOTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most
More informationColt CoolStream Adiabatic Cooling & Ventilation System
Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt coolstream Adiabatic cooling & ventilation system DESCRIPTION Colt CoolStream is a natural
More informationmore than just a fan supplier more than just a fan supplier Axair Fans UK Limited
1 more than just a fan supplier The most diverse range of industrial fans & accessories available from a single source... 2 products oem & industrial 3 single inlet centrifugal backward curved centrifugal
More informationInline mixed-flow fans with the air capacity up to 1850 m 3 /h
FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design
More informationWhole Home Heat Recovery Ventilation
Whole Home Heat Recovery Ventilation Lossnay VL220. Clean Fresh Air; for a Healthier, Drier and Warmer Home. Balanced Pressure Home Ventilation. Made in Japan, Designed for New Zealand Conditions. Lossnay
More information87cm. Cooker hood. Stainless steel JLCEILHD87. User guide
87cm Cooker hood Stainless steel JLCEILHD87 User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5
More informationWORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS
WORLD VENTILATION LEADER IO EM.COM SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS VENTS reserves the rights to modify any of its products featuers, designs, components and specifications
More information60cm Canopy Extractor
60cm Canopy Extractor LAM2300 User & Installation Guide Dear Customer, Congratulations on your choice of domestic appliance which has been designed to give you excellent service. The user manual will help
More informationECO dmev Decentralised MEV
ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the
More informationInline mixed-flow fans with the air capacity up to 450 m 3 /h
FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design
More informationJLBIHD624 60cm Cooker Hood
JLBIHD624 60cm Cooker Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions
More informationTELESCOPIC HOOD SL10160I-3 SRECO160I-2 TECHNIKA USER S MANUAL 安装和 INSTRUCTIONS FOR INSTALLATION AND USE 使用指示
SL10160I-3 SRECO160I-2 TELESCOPIC HOOD USER S MANUAL For original parts & reliable service: TECHNIKA 1800 333 244 使用指示 安装和 INSTRUCTIONS FOR INSTALLATION AND USE Table of Contents Schematic Diagram From
More informationINTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation
JAU /JCC/JVC Series Jet Fans - for car park ventilation INTRODUCTION Pacific HVAC Engineering is able to offer a complete solution in car park ventilation at a competitive price with in house developed
More informationALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector
ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential
More informationInstructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods
Instructions for the Use and Care and Installation of ORW6XA ORW9XA Wall Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationINSTALLATION INSTRUCTIONS USER GUIDE
INSTALLATION INSTRUCTIONS USER GUIDE Tilted wall cooker hood HT90GHB2 model GB IE CONTENTS Introduction 3 Safety and warnings 4 Installation instructions 8 About your cooker hood Energy efficiency 18
More informationBT16.4SS-HK BT19.4SS-HK Cooker Hood
BT16.4SS-HK BT19.4SS-HK Cooker Hood User Manual for your Baumatic User Manual for your Baumatic BT16.4SS-HK 60 cm Chimney Hood BT19.4SS-HK 90 cm Chimney Hood NOTE: This User Instruction Manual contains
More informationChrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover
Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when
More informationInstruction Manual JLHDA cm Cooker hood
Contents 3 Introduction 3 Safety is important 3 In the box 4 Safety information 4 Important safety information 4 Warnings 5 Cautions 5 Electrical information 6 Remote control 6 Programming the remote control
More informationInstructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods
Instructions for the Use and Care and Installation of ORC97G ORC98G Glass Canopy Rangehoods CONTENTS 1 Notice 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7 Maintenance
More informationAerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D
USA COOKER HOOD USER INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS EFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical
More informationINDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11
INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this
More informationCHAPTER 5: EXHAUST SYSTEMS
MOTORS, FANS AND FILTERS 503.1 General. Motors and fans shall be sized to provide the required air movement. Motors in areas that contain flammable vapors or dusts shall be of a type approved for such
More informationColt CoolStream Evaporative Cooling & Ventilation System
Colt CoolStream Evaporative Cooling & Ventilation System Colt CoolStream Evaporative Cooling & Ventilation System Colt CoolStrEam Adiabatic cooling & ventilation system DeSCrIPtIoN Colt CoolStream is a
More informationJLBIHD920 90cm Chimney Hood
JLBIHD920 90cm Chimney Hood User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information 5 Warnings 5 Cautions
More informationBelling Cooker Hood User Manual
Belling Cooker Hood User Manual 1 Contents Introduction................................................ 3 Using the Hood.............................................. 4 Care and Maintenance.........................................
More informationPRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h
PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central
More informationStoves Cooker Hood User Manual
Stoves Cooker Hood User Manual Contents Introduction................................................. 3 Using the Hood.............................................. 4 Care and Maintenance.........................................
More informationPRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation
PRODUCT DATA NILAIR BY NILAN Air distribution Domestic Ventilation NILAIR NilAIR is installed together with a ventilation unit,which in simple terms consists of distribution boxes from which tubes are
More informationFUME EXTRACT STRATEGY STATEMENT
FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular
More informationKOMFORT EC DB Suspended heat recovery air handling units
2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.
More informationTechnical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging
Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013
More informationApartment Ventilation. "Microbox" Continuous Mechanical Extract Units
Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation
More informationRWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.
RWC Issue: F Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX Model may vary slightly from images pictured. All measurements are in mm. 1 Overview Pre-installation Thank you for purchasing a quality
More informationFRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %
FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 % FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION
More informationCHAPTER 6 CONDENSING UNITS
CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.
More informationInstructions Manual SHC520X - SHC700X
Instructions Manual SHC520X - SHC700X INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for
More informationKVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology
KVF Capture Jet Canopy with Supply Air and Side-Jet Technology ALLIED EBER R LISTED HACCP* certified (PE-567-H01I). 30 to 40% reduction in exhaust airflow rates thanks to the Capture Jet technology. High-efficiency
More informationUV-TURBO HOODS. Product Brochure
UV-TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 0 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 UV-TURBO GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...
More informationA B C D E F 2
HOOD RS600 A B C D E F 2 3 4 7 11 EN DECORATIVE EXTRACTOR HOOD Dear Customer, Thank you for buying our hood. Please read these instructions carefully for its optimum installation, use and maintenance.
More informationStainless Steel and Glass Angled Extractor
Stainless Steel and Glass Angled Extractor HJA2600 User & Installation Guide CONTENTS Environmental Note 3 Product information 4 4 Parts List 4 Method of Extraction 5 Installation 6 Hanging Your Extractor
More informationFlexit air handling units UNI 2, 3 og 4
Flexit handling units UNI 2, 3 og 4 energy efficient ventilation for a healthy indoor environment FOR A HEALTHY INDOOR ENVIRONMENT Energy-efficient ventilation Flexit UNI 2, 3 and 4 The handling units
More informationSlider hood Grey metal/stainless steel panel JLHDA601
60cm Slider hood Grey metal/stainless steel panel JLHDA601 User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationCI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS...
CI/SfB (57) Uniclass Pr_30_59_96 December 2017 TRICKLE VENTILATORS... ................................................ TRICKLE VENTILATORS..................................................................
More information60cm Chimney Extractor
60cm Chimney Extractor LAM2401 HJA2480 User & Installation Guide Contents Page Environmental note 3 IMPORTANT SAFETY INFORMATION 4 6 Specifications of your extractor 7 8 Dimensions 7 Specifications 7-8
More informationCapture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING
FILTERMAX FilterMax is a complete filter solution for the entire workshop. Irrespective of whether you extract welding fumes or dust, use extraction arms or permanent built-in capture hoods, FILTER MODULES
More informationFlue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections
Now includes a Pressure Safety Switch and easier Electrical Connections Flue Dilution Fans VISIT US AT www.airflow.com UK SALESLINE 0845 330 1047 Specialists in Air Movement Technology SAFETY - NEW Differential
More informationKOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators
KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS
More information90cm Stainless steel pyramid canopy hood with 850 cubic m/h extraction and high output LED lighting
90cm Stainless steel pyramid canopy hood with 850 cubic m/h extraction and high output LED lighting RRP AUS $719.00-90cm Stainless steel pyramid canopy hood Product Details FEATURES Power Twin Blade centrifugal
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationELECTROSTATIC FILTER 1000
EDIA FILTER MF1000 ELECTROSTATIC FILTER 1000 ELECTROSTATIC FILTER 1000 The acs 1000 is designed for direct attachment to most machines and machining centres. Isolator Isolator for start/stop and mains
More informationST E /ST E / ST E / ST E ST E / ST E / ST E
ST-5-3-E /ST-5-4-E / ST-53-3-E / ST-53-4-E ST-533-40-E / ST-55-40-E / ST-59-40-E Turbo Electric Heater 800083-4 ENGLISH...-0 Read The Instruction manual: When this symbol is marked on a product, it means
More informationUSER MANUAL EFC60001 EFC70001 EFC90001
USER MANUAL EFC60001 EFC70001 EFC90001 We were thinking of you when we made this product electrolux 3 RECOMMDATIONS AND SUGGESTIONS 5 CHARACTERISTICS 6 INSTALLATION 8 USE 11 MAINTANCE 12 Welcome to the
More informationThe Straight Way K Sileo Series
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way K Series Systemair Sdn Bhd certifies that the K fans shown herein are licensed
More informationIsland Extractor. Instructions & Installation LAM
Island Extractor LAM2850 Instructions & Installation www.howdens.com/appliance-registration See back page for product serial number Dear Customer, Congratulations on your choice of domestic appliance.
More informationFume extraction system FEC.
TECHNOLOGY FOR THE WELDER S WORLD. Fume extraction system FEC. Weld fume extraction with cyclone technolgy! www.binzel-abicor.com Easy handling! Highest suction power. Fume extraction system FEC Harmful
More informationEN Instruction on mounting and use
EN Instruction on mounting and use EN - Instruction on mounting and use Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires
More informationElectrostatic Precipitator
lectrostatic Precipitator Manual Clean & Autowash System the SP solution to grease and smoke pollution... Local Legislation Local Legislation requires increasingly that the amount of grease and smoke in
More informationCooker hood Stainless steel/curved glass JLHDA623
60cm Cooker hood Stainless steel/curved glass JLHDA623 User guide 2 Cooker hood user guide Contents Contents 3 Introduction 4 Safety is important 4 In the box 4 Safety information 5 Important safety information
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor HJA2450-2 User & Installation Guide LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you
More informationMECHANICAL VENTILATION
MECHANICAL VENTILATION Natural and Mechanical Systems Four (4) possible combinations of natural and mechanical ventilations tions are as follows; Natural inlet and outlet; utilizing open able windows,
More informationMRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)
NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationORC93XA ORC94XBA. Wall Canopy Rangehoods
Instructions for the Use and Care and Installation of ORC93XA ORC94XBA Wall Canopy Rangehoods CONTENTS 1 Warning 2 Features 3 Installation 4 Notice of installation 5 Safety Warning 6 Use Instructions 7
More informationTURBO HOODS. Product Brochure
TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 04 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 TURBOSWING GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...
More informationwe make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)
we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established
More informationAir circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.
Air circulation Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year. At work employers are legally obliged to ensure that during working hours
More informationINSTALLATION INSTRUCTIONS USER GUIDE
INSTALLATION INSTRUCTIONS USER GUIDE Standard Rangehood HF60LX4 and HF60LW4 model NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 13 Cleaning and maintenance 14
More informationStainless Steel Chimney Extractor
Stainless Steel Chimney Extractor User & Installation Guide LAM2404 LAMONA Appliances Dear Customer, Congratulations on your choice of a LAMONA domestic appliance which has been designed to give you excellent
More informationCLEANAIRE. The energy efficient way to achieve a dry, healthy home. Product Information
The energy efficient way to achieve a dry, healthy home CLEANAIRE The Genuine Heat Recovery Ventilator (HRV) Product Information All that you need is the air that you breathe - make sure its cleanaire
More informationTUNNEL FANS STANDARD AND HOT SMOKE
TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC
More informationENVIRO UNIT ENGINEERING MANUAL KES SERIES
ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units
More informationFLUEBOOST. flueboost 350 gas fire model
350 FLUEBOOST flueboost 350 gas fire model The flueboost is a box shaped unit with in line spigots for the flue connection, a pressure switch to ensure safe operation and plug-in electrical fittings for
More informationCentral Heating and Ventilation
Central Heating and Ventilation Highly Efficient Ducted Heating, Cooling and Ventilation Quiet, Unobtrusive Comfort for Your Whole Home Efficient Comfort for Your Whole Home Ducted Heat Pumps Heat or Cool
More information