MODELS D1EH018 THRU 060, 1-1/2 THRU 5 TON (12 SEER) AND MODELS D1EM036 THRU 060, 3 THRU 5 TON (13 SEER)
|
|
- Rodger White
- 5 years ago
- Views:
Transcription
1 INSTALLATI INSTRUCTI CHAMPI SERIES SINGLE PACKAGE AIR CDITIERS ELECTRIC/ELECTRIC, AIR-COOLED Supersedes: 6666-YIM-A-0404/ A YIM-B-004 MODELS DEH08 THRU 060, -/ THRU 5 T ( SEER) AND MODELS DEM036 THRU 060, 3 THRU 5 T (3 SEER) GENERAL Models DEH and DEM units are factory assembled cooling only air conditioners designed for outdoor installation on a rooftop or a slab. Field-installed electric heater accessories are available to provide electric heat combined with electric cooling. The units are completely assembled on rigid, but easily removable base rails. All piping, refrigerant charge, and electrical wiring is factory installed and tested. The units require only electric power and duct connections at the point of installation. The electric heaters have nickel-chrome resistance wire elements and utilize single point power connection. INSPECTI As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. Refer to Form 50.5-NM for additional information. REFERENCE Additional information on the design, installation, operation and service of this equipment is available in the following reference forms: N -General Installation N -Pre-start & Post-start Check List 5.6-N.V -Electric Heater Accessory REPLACEMENT PARTS Refer to Replacement Parts Manual for complete listing of replacement parts on this equipment. Installer should pay particular attention to the words: NOTE, CAUTI and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly. CAUTI THIS PRODUCT M UST BE INSTALLED IN STRICT COMPLIANCE W ITH THE ENCLOSED INSTALLATI INSTRUCTIS AND ANY APPLICABLE LOCAL, STATE, AND NATIAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES. WARNING INCORRECT INSTALLATI MAY CREATE A CDITI WHERE THE OPERATI OF THE PRODUCT COULD CAUSE PERSAL INJURY OR PROPERTY DAMAGE.
2 6666-YIM-B-004 PRODUCT CATEGORY D = Single Package Air Conditioner (Air Cooled) PRODUCT GENERATI = NEW or Current Design PRODUCT IDENTIFIER EH = SEER Cooling Models EM = 3 SEER Cooling Models LIMITATIS These units must be installed in accordance with the following national and local safety codes.. National Electrical Code ANSI/NFPS No. 70 or Canadian Electrical Code Part, C. (latest editions).. Local plumbing and waste water codes and other applicable local codes. Refer to Table for unit application data and to Tables 5 and 6 for electric heat application data. If components are to be added to a unit to meet local codes, they are to be installed at the dealer's and/or the customer's expense. Rated in accordance with ARI Standard 0, utilization range A. A low ambient accessory is available for operation down to 0 F 3 T" transformer primary tap must be moved from the 30 volt connection to the 08 volt connection for low voltage applications of 08 volt and below. Size of unit for proposed installation should be based on heat loss/heat gain calculations made in accordance with industry recognized procedures identified by the Air Condition- TABLE - UNIT APPLICATI DATA 3 08/30V 87 / 53 3 Voltage Variation Min. / Max. 460V 44 / V 58 / 630 Wet Bulb Temperature ( F) of Air on 57 / 7 Evaporator Coil, Min. / Max. Dry Bulb Temperature ( F) of Air on Condenser Coil, Min. 45 / 0 / Max. ing Contractors of America. LOCATI Use the following guidelines to select a suitable location for these units.. Unit is designed for outdoor installation only.. Condenser must have an unlimited supply of air. Where a choice of location is possible, position unit on either north or east side of building. 3. For ground level installation, a level pad or slab should be used. The thickness and size of the pad or slab used should meet local codes and unit weight. Do not tie the slab to the building foundation. PRODUCT NOMENCLATURE D E H 0 4 A 0 6 NOMINAL COOLING CAPACITY (MBH) 08 = 8,000 BTUH 04 = 4,000 BTUH 030 = 30,000 BTUH 036 = 36,000 BTUH 04 = 4,000 BTUH 048 = 48,000 BTUH 060 = 60,000 BTUH INSTALLATI VOLTAGE CODE 06 = 08/ = 08/ = = FACTORY INSTALLED ELECTRIC HEAT A = No Electric Heat Installed 4. For roof top installation, be sure the structure will support the weight of the unit plus any field installed components. Unit must be installed on a level roof curb or appropriate angle iron frame providing adequate support under the compressor/condenser section. 5. Maintain level tolerance of unit to /8" maximum. RIGGING OR HANDLING Care must be exercised when moving the unit. Do not remove any packaging until the unit is near the place of installation. Rig unit with slings placed under the unit. Spreader bars of sufficient length should be used across the top of the unit. BEFORE LIFTING A UNIT, MAKE SURE THAT ITS WEIGHT IS DISTRIBUTED EQUALLY THE CABLES SO THAT IT WILL LIFT EVENLY. Units may also be moved or lifted with a fork-lift. Slotted openings in the skid are provided for this purpose. Forks must pass completely through the base. TABLE - UNITS WEIGHTS UNIT SIZE FRT OF UNIT SHIPPING WEIGHT (lbs.) "' & OPERAT- ING WEIGHT (lbs.) A 6 D B FIG. - CENTER OF GRAVITY CORNER WEIGHTS (location, lbs.) A B C D ! CENTER OF GRAVITY C "% " Unitary Products Group
3 6666-YIM-B-004 Refer to Table for unit weights and to Figure for approximate center of gravity. CLEARANCES All units require certain clearances for proper operation and service. Refer to Figure 6 for the clearances required for combustion, construction, servicing and proper unit operation. WARNING:Do not permit overhanging structures or shrubs to obstruct the condenser air discharge outlet. DUCT WORK These units are adaptable to downflow use as well as rear supply and return air duct openings. To convert to downflow, use the following steps:. Remove the duct covers found in the bottom return and supply air duct openings. There are four (4) screws securing each duct cover (save these screws to use later).. Install the duct covers, removed in step one, to the rear supply and return air duct openings. Secure with the four (4) screws used in step one. 3. Seal the duct covers with silicone caulking. Downflow units must have an L-shaped supply duct without any outlets or registers located directly below the supply outlet of the unit. Duct work should be designed and sized according to the methods of the Air Conditioning Contractors of America (ACCA), as set forth in their Manual D. A closed return duct system shall be used. This shall not preclude use of economizers or ventilation air intake. Flexible joints may be used in the supply and return duct work to minimize the transmission of noise. CAUTI: When fastening duct work to the side duct flanges on the unit, insert the screws through the duct flanges only. DO NOT insert the screws through the casing. Outdoor duct work must be insulated and waterproofed. NOTE: Be sure to note supply and return openings. Refer to Figure 6 for information concerning rear and bottom supply and return air duct openings. FILTERS Single phase units are shipped without a filter and is the responsibility of the installer to secure a filter in the return air ductwork or install a Filter/Frame Kit (FF04). A filter rack and a filters are standard on three phase units. Filters must always be used and must be kept clean. When filters become dirt laden, insufficient air will be delivered by the blower, decreasing your units efficiency and increasing operating costs and wear-and-tear on the unit and controls. Filters should be checked monthly especially since this unit may be used for both heating and cooling. CDENSATE DRAIN A condensate trap is required to be installed in the condensate drain. The plumbing must conform to local codes. Use a sealing compound on male pipe threads. Install the condensate drain line (! " NPTF) to spill into an open drain. SERVICE ACCESS Access to all serviceable components is provided by the following removable panels: Blower service access Electrical/filter access Compressor service access Refer to Figure 6 for location of these access panels and minimum clearance. THERMOSTAT The room thermostat should be located on an inside wall approximately 56" above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or appliances. Follow manufacturer's instructions enclosed with the thermostat for general installation procedure. Four, five or six color coded insulated wires (minimum #8 AWG) should be used to connect thermostat to unit. See Figure 3. POWER AND CTROL WIRING Field wiring to the unit must conform to provisions of the current N.E.C. ANSI/NFPA No. 70 or C.E.C. and/or local ordinances. The unit must be electrically grounded in accordance with local codes or, in their absence, with the N.E.C./C.E.C. Voltage tolerances which must be maintained at the compressor terminals during starting and running conditions are indicated on the unit Rating Plate and Table. The wiring entering the cabinet must be provided with mechanical strain relief. A fused or HACR breaker disconnect switch should be field provided for the unit. If any of the wire supplied with the unit must be replaced, replacement wire must be of the type shown on the wiring diagram. Electrical line must be sized properly to carry the load. Each unit must be wired with a separate branch circuit fed directly from the meter panel and properly fused. Refer to Figure for typical field wiring and to the appropriate unit wiring diagram for control circuit and power wiring information. COMPRESSORS Units are shipped with compressor mountings factory-adjusted for shipping. CAUTI: Loosen compressor mounting bolts half turn before operating unit. Cooling The following sequences of operation are based on using a standard single-stage cooling thermostat. Unitary Products Group 3
4 6666-YIM-B-004 TABLE 3 - PHYSICAL DATA MODELS DEH EVAPORATOR CENTRIFUGAL BLOWER (Dia. x Wd. in.) 9 x 6 0 x 8 0 x 8 0 x 8 x 0 x 0 x 0 BLOWER FAN MOTOR HP(Threre Speed, Direct Drive)! "! "! " ROWS DEEP EVAPORATOR FINS PER INCH COIL FACE AREA (Sq. Ft.) PROPELLER DIA. (in.) CDENSER FAN MOTOR HP FAN " " " " "!! NOM. CFM TOTAL,800,800,800,800,400 3,000 3,000 ROWS DEEP CDENSER FINS PER INCH COIL FACE AREA (Sq. Ft.) CHARGE REFRIGERANT (lbs./oz.) 5 / 5 5 / 3 4 / 7 4 / 5 / 0 7 / 0 9 / 0 FILTER FACE AREA (Sq. Ft. / Qty. / Size).4 / / 4" x " COMPRESSOR HERMETIC, QTY. = (Type) Reciprocating Reciprocating Scroll Scroll Scroll Scroll Scroll MODELS DEM EVAPORATOR CENTRIFUGAL BLOWER (Dia. x Wd. in.) 0 x 8 x 0 x 0 BLOWER FAN MOTOR HP (ECM)! " ROWS DEEP EVAPORATOR FINS PER INCH COIL FACE AREA (Sq. Ft.) PROPELLER DIA. (in.) CDENSER FAN MOTOR HP FAN "!! NOM. CFM TOTAL,800 3,000 3,000 ROWS DEEP CDENSER FINS PER INCH COIL FACE AREA (Sq. Ft.) CHARGE REFRIGERANT (lbs./oz.) 4 / 6 6 / 0 7 / FILTER FACE AREA (Sq. Ft. / Qty. / Size).4 / / 4" x " COMPRESSOR HERMETIC, QTY. = (Type) Scroll Scroll Scroll ECM = Electrically Controlled Motor ** = Minimum wire size of 8 AWG wire should be used for all field installed 4 volt wire. PROGRAMMABLE THERMOSTAT LY * = Only required on units with supplemental electric heat. THERMOSTAT 4 / ; 9 + CTROL WIRING ** * * 9 9 UNIT TERMINAL STRIP 4 / ; 9 + POWER WIRING NOTE: HEAT ANTICIPATOR SHOULD BE SET AT 0.5 AMPS FOR ALL MODELS. 4 VOLT TRANSFORMER CAUTI: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. REFER TO ELECTRICAL DATA TABLES TO SIZE THE DIS- CNECT SWITCH, WIRING & OVERCURRENT PROTEC- FIG. - TYPICAL FIELD WIRING DIAGRAM REFER TO ELECTRICAL DATA TABLES TO SIZE THE DIS- CNECT SWITCH, WIRING & OVERCURRENT PROTEC- 4 Unitary Products Group
5 6666-YIM-B-004 TABLE 4 - ELECTRICAL DATA (BASIC UNIT) MODEL POWER SUP- DEH PLY VOLTAGE LIMITATIS COMPRESSOR MIN. MAX. RLA LRA CD. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, AMPS MAX. HACR BREAKER SIZE, AMPS UNIT POWER FACTOR TRANS-FORMER SIZE (VA) 08 08/ / / / / / / / MODEL POWER SUP- DEM PLY VOLTAGE LIMITATIS COMPRESSOR MIN. MAX. RLA LRA CD. FAN MOTOR, FLA SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, AMPS MAX. HACR BREAKER SIZE, AMPS UNIT POWER FACTOR TRANS-FORMER SIZE (VA) / / / / / =Rated in accordance with ARI Standard 0, utilization range A. = Dual element, time delay type. Unitary Products Group 5
6 6666-YIM-B-004 TABLE 5 - ELECTRICAL DATA (COOLING / ELECTRIC HEAT) DEH08, 04, 030, 036, 04, 048, 060 DEH MODEL POWER SUPPLY COMPRESSOR CD. FAN MOTOR FLA SUPPLY AIR BLOWER MOTOR, RLA LRA FLA MODEL NO. ELECTRIC HEAT ACCESSORY STAGE KW TOTAL AMPS MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, AMPS MAX. HACR BREAKER SIZE 08 08/ NH NH NH / NH NH NH / NH NH NH NH / NH NH NH NH / NH NH NH / NH NH / NH NH / NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH NH = Dual element, time delay type. = Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. 3.8/5.0 * 5.6/7.5 * 3.8/5.0 * 5.6/7.5 * 7.5/0.0 * 3.8/5.0 * 5.6/7.5 * 7.5/0.0 *.3/5.0 * 3.8/5.0 * 5.6/7.5 * 7.5/0.0 *.3/5.0 * 3.8/5.0 * 5.6/7.5 * 7.5/0.0 *.3/5.0 * 7.5/0.0 *.3/5.0 * 7.5/0.0 *.3/5.0 * 7.5/0.0 *.3/5.0 * 0.0 ** 5.0 ** 0.0 ** 5.0 ** 0.0 ** 5.0 ** 0.0 *** 5.0 *** 0.0 *** 5.0 *** 0.0 *** 5.0 *** 0.0 *** 5.0 *** 0.0 *** 5.0 *** 0.0 *** 5.0 *** 8./0.8 7./3.3 8./0.8 7./ /4.7 8./ / / /6.5 8./0.8 7./ / /6.5 8./0.8 7./ / / /4. 3.3/ /4. 3.3/ /4. 3.3/ / / / / / / / / / / / / / / / / / / / / / / / /30 40/45 30/30 40/45 50/60 30/30 40/45 50/60 35/40 40/45 50/60 40/40 50/50 50/60 30/35 45/50 35/35 45/50 35/35 45/ * = KW listed is for 40 volts, use this table for 08 or 30 volts. ** = KW listed is for 480 volts, use this table for 460 volts. *** = KW listed is for 600 volts, use this table for 575 volts. 30/30 40/45 30/30 40/45 50/60 30/30 40/45 50/60 35/40 40/45 50/60 40/40 50/50 50/60 30/35 45/50 35/35 45/50 35/35 45/ ELECTRIC HEAT CORRECTI FACTORS NOMINAL VOLTAGE VOLTAGE KW CAP. MULTI- PLIER Unitary Products Group
7 6666-YIM-B-004 TABLE 6 - ELECTRICAL DATA (COOLING / ELECTRIC HEAT) DEM036, 048, 060 DEM MODEL POWER SUPPLY COMPRESSOR CD. FAN MOTOR FLA SUPPLY AIR BLOWER MOTOR, RLA LRA FLA MODEL NO. ELECTRIC HEAT ACCESSORY STAGE KW TOTAL AMPS MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, AMPS MAX. HACR BREAKER SIZE / NH NH NH NH NH / NH NH NH NH / NH NH NH NH / NH NH NH NH / NH NH NH NH NH NH NH NH NH NH NH = Dual element, time delay type. = Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. 3.8/5.0 * 5.6/7.5 * 7.5/0.0 *.3/5.0 * 7.5/0.0 *.3/5.0 * 5.0/0.0 * 8.8/5.0 * 7.5/0.0 *.3/5.0 * 5.0/0.0 * 8.8/5.0 * 7.5/0.0 *.3/5.0 * 5.0/0.0 * 8.8/5.0 * 7.5/0.0 *.3/5.0 * 5.0/0.0 * 8.8/5.0 * 0.0 ** 5.0 ** 0.0 ** 5.0 ** 0.0 ** 5.0 ** 0.0 ** 5.0 ** 8./0.8 7./ / / / /6.5 7./ / / /6.5 7./ / /4. 3.3/ /48. 5./ /4. 3.3/ /48. 5./ / / / / / / /3.3.0/ / / / / / /54. 6./ / / / / / /40 40/45 60/60 60/70 00/5 5/50 70/70 0/5 5/50 40/40 50/60 70/70 50/50 60/60 70/ * = KW listed is for 40 volts, use this table for 08 or 30 volts. ** = KW listed is for 480 volts, use this table for 460 volts. 35/40 40/45 60/60 60/70 00/5 5/50 70/70 0/5 5/50 40/40 50/60 70/70 50/50 60/60 70/ ELECTRIC HEAT CORRECTI FACTORS NOMINAL VOLTAGE VOLTAGE KW CAP. MULTI- PLIER Unitary Products Group 7
8 6666-YIM-B-004 Checking Supply Air CFM To check the supply air CFM after the initial balancing has been completed:.remove the two ¼ inch dot plugs in the duct panel..insert at least 8 inches of ¼ inch tubing into each of these holes for sufficient penetration into the airflow on both sides of the indoor coil. 3.Using an inclined manometer, determine the pressure drop across the dry evaporator coil. Since the moisture on an evaporator coil may vary greatly, measuring the pressure drop across a wet coil under field conditions would be inaccurate. To ensure a dry coil, the compressors should be deactivated while the test is being run. 4.Knowing the pressure drop across a dry coil, the actual CFM through the unit can be determined from the curve in Coil Delta P vs. Supply Air CFM figure. WARNING! Failure to properly adjust the total system air quantity can result in extensive system damage. After readings have been obtained, remove the tubes and reinstall the two ¼ inch plugs removed in Step. NOTE: De-energize the compressors before taking any test measurements to ensure a dry indoor coil. DEH Coil Delta P vs Airflow 0.4 DEH DEH ID Coil Delta P DEH08 DEH04 DEH030 DEH04 DEM Linear (DEH08) Linear (DEH030) Linear (DEH04) Linear (DEH04) Linear (DEM048-60) DEH03 DEH Airflow (CFM) 8 Unitary Products Group
9 6666-YIM-B-004 TABLE 7 - SUPERHEAT CHARGING TABLE FOR MODEL DEH08 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) TABLE 8 - SUPERHEAT CHARGING TABLE FOR MODEL DEH04 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) TABLE 9 - SUPERHEAT CHARGING TABLE FOR MODEL DEH030 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) TABLE 0 - SUPERHEAT CHARGING TABLE FOR MODEL DEH036 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) Unitary Products Group 9
10 6666-YIM-B-004 TABLE - SUPERHEAT CHARGING TABLE FOR MODEL DEH04 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) TABLE - SUPERHEAT CHARGING TABLE FOR MODEL DEM036 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) TABLE 3 - SUPERHEAT CHARGING TABLE FOR MODEL DEM048 OUTDOOR SUPERHEAT AT COMPRESSOR SUCTI (F), AIRFLOW = 400 CFM/T TEMPERATURE INDOOR WB TEMPERATURE (F) (F) Unitary Products Group
11 6666-YIM-B-004 DISCHARGE PRESSURE OUTDOOR DRY BULB TEMP FIG. 3 - DEM060 DISCHARGE PRESSURE/TEMPERATURE (utilizes a thermal expansion valve) SUCTI CFM OUTDOOR DRY BULB TEMPERATURE FIG. 4 - DEM060 SUCTI PRESSURE/TEMPERATURE (utilizes a thermal expansion valve) SUCTI 000 CFM OUTDOOR DRY BULB TEMPERATURE FIG. 5 - DEM060 SUCTI PRESSURE/TEMPERATURE (utilizes a thermal expansion valve) Unitary Products Group
12 6666-YIM-B-004 HIGH VOLTAGE CN.!! " DIA. KNOCKOUT LOW VOLTAGE CN. % & DIA. KNOCKOUT SIDE SUPPLY AIR OPENING HIGH VOLTAGE CN. % & " DIA. KNOCKOUT FRT! & A (OVERALL) COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL UNIT SIZE DIMENSI A SIDE RETURN AIR OPENING REFRIGERANT CNECTIS ELECTRICAL/FILTER SERVICE ACCESS COMPARTMENT PANEL "' & (OVERALL) & " " % " % " " & " "% " (OVERALL) HIGH VOLTAGE CN.! $"" DIA. KNOCKOUT!! " LOW VOLTAGE CN. % & DIA. KNOCKOUT 4 UNIT CDENSATE CNECTI! " NPTI (TRAP REQUIRED) FRT All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. HIGH VOLTAGE CN.!! x % &" DIA. KNOCKOUT SIDE SUPPLY AIR OPENING " "! " $! " &! & 6 CDENSATE DRAIN! " NPTI CDENSER COIL "!! & BACK SIDE RETURN AIR OPENING BOTTOM SUPPLY AIR OPENING CLEARANCES (Minimum) Front " Back 0" Left Side (Filter Access) 4" Right Side 4" Below Unit 0" Above Unit 36" (For Condenser Air Discharge) Units may be installed on combustible floors made from wood or class A,! " 5 & ' $ 5!! &! " 5 4 "! BOTTOM RETURN AIR OPENING B or C roof covering material.! " Units must be installed outdoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. FIG. 6 - DIMENSIS AND CLEARANCES Unitary Products Group
13 6666-YIM-B-004 SEQUENCE OF OPERATI FOR DEH MODELS WITH POWER TO UNIT AND THERMOSTAT IN COOLING MODE.. If the fan switch on the thermostat is in the position, the 4 volts at G will energize the K" relay on the fan control board, close the K" relay contacts, and energize the indoor blower motor. If the fan switch is in the AUTO position, the blower will operate only when there is a call for cooling by the thermostat.. On a call for cooling, the thermostat will send 4 volts to Y on the fan control board. The 4 volt signal will energize contactor M", and power will be supplied to the compressor and outdoor fan motor. If the fan switch on the thermostat is on the AUTO" position, the thermostat will also send a 4 volt signal to G on the fan control board and the indoor blower will operate as indicated in step. 3. When the demand for cooling has been satisfied, the M" contactor will be de-energized when the 4 volt Y" signal is removed. If the fan switch on the thermostat is energized when the 4 volt Y signal is removed. If the fan switch on the thermostat is in the position, the indoor blower will continue to run. If the fan switch is in the AUTO position, the 4 volt G signal will be removed, and after a 60 second delay, the K" relay will open and de-energize the indoor blower motor. Heating WITH POWER TO UNIT AND THERMOSTAT IN HEATING MODE.. If the fan switch on the thermostat is in the position, the 4 volts at G will energize the K" relay contacts, and energize the indoor blower motor. If the fan switch on the thermostat is in the AUTO" position, the blower will operate only when there is a call for heating by the thermostat.. On a call for heating, the thermostat will send 4 volts to W" on the fan control board. The 4 volts signal will energize relay K" on the fan control board, and the first stage of electric heat will be energized. 3. When the heating demand is satisfied, the electric heat will be de-energized when the 4 volt W" and W" signals are removed. If the fan switch on the thermostat is in the position, the indoor blower will continue to run. If the fan switch is in the AUTO position, the K" relay will open and de-energize the indoor blower motor after the appropriate time delay. Please refer to Table 4 and 5 for more information. Cooling SEQUENCE OF OPERATI FOR DEM MODELS The following sequences of operation are based on using a standard single-stage cooling thermostat. Heating WITH POWER TO UNIT AND THERMOSTAT IN HEATING MODE. WITH POWER TO UNIT AND THERMOSTAT IN COOLING MODE.. If the fan switch on the thermostat is in the position, the 4 volts at G will be sent to the ECM indoor motor and the blower will operate at the programmed airflow. If the fan switch is in the AUTO position, the blower will operate at the programmed airflow only when there is a call for cooling by the thermostat.. On a call for cooling, the thermostat will send 4 volts to Y on the fan control board. The 4 volt signal will energize contactor M", and power will be supplied to the compressor and outdoor fan motor. If the fan switch on the thermostat is on the AUTO" position, the thermostat will also send a 4 volt signal to G on the fan control board and the indoor blower will operate as indicated in step. 3. When the demand for cooling has been satisfied, the M" contactor will be de-energized when the 4 volt Y" signal is removed. If the fan switch on the thermostat is in the position, the indoor blower will continue to run. If the fan switch is in the AUTO position, the 4 volt G signal will be removed, and after a 30 second delay, the indoor blower motor will shut down.. If the fan switch on the thermostat is in the position, the 4 volts at G will be sent to the ECM indoor motor and the blower will operate at the programmed airflow. If the fan switch is in the AUTO position, the blower will operate at the programmed airflow only when there is a call for heating by the thermostat.. On a call for heating, the thermostat will send 4 volts to W" on the fan control board. The 4 volts signal will energize relay K" on the fan control board, and the first stage of electric heat will be energized. The indoor blower will operate as indicated in step. 3. On units with (two) stages of electric heat, the second bank of heaters will be energized by a 4 volt signal to W" on the fan control board. After a 0 second delay, the third bank of heaters will be energized if the unit is so equipped. 4. When the heating demand is satisfied, the electric heat will be de-energized when the 4 volt W" and W" signals are removed. If the fan switch on the thermostat is in the position, the indoor blower will continue to run. If the fan switch is in the AUTO position, the indoor motor will shut off after the appropriate time delay. Please refer to Table 4 and 5 for more information. Unitary Products Group 3
14 6666-YIM-B-004 TABLE 4 - THERMOSTAT SIGNALS (SINGLE PHASE UNITS) SIGNAL STATE BOARD FUNCTI SIGNAL STATE BOARD FUNCTI G G Y G W" G W" W" FAN INSTANT COMPRESSOR AND OUTDOOR COMPRESSOR AND OUTDOOR FAN INSTANT FAN 60 SECD DELAY DEH MODELS FAN 30 SECD DELAY DEM MODELS HEATER BANK (HTR ) INSTANT HEATER BANK (HTR ) INSTANT FAN 0 SECD DELAY W" W" HEATER BANK (HTR ) INSTANT HEATER BANK (HTR & HTR 3) 0 SEC. DELAY HEATER BANK 3 (HTR 4 & HTR 5) 0 SEC. DELAY W" HEATER BANK 3 (HTR 4 & HTR 5) INSTANT W" HEATER BANK (HTR & HTR 3) SEC. DELAY HEATER BANK (HTR ) SECD DELAY FAN 0 SECD DELAY HEATER BANK (HTR ) INSTANT HEATER BANK (HTR ) INSTANT FAN 0 SECD DELAY HEATER BANK (HTR ) INSTANT HEATER BANK (HTR & HTR 3) 0 SEC. DELAY HEATER BANK (HTR & HTR 3) INSTANT HEATER BANK (HTR ) SECD DELAY FAN 0 SECD DELAY HEATER BANK (HTR ) INSTANT HEATER BANK (HTR & HTR 3) 0 SEC. DELAY HEATER BANK 3 (HTR 4 & HTR 5) 0 SEC. DELAY HEATER BANK 3 (HTR 4 & HTR 5) INSTANT HEATER BANK (HTR & HTR 3) SEC. DELAY HEATER BANK (HTR ) SECD DELAY FAN 0 SECD DELAY TABLE 5 - THERMOSTAT SIGNALS (THREE PHASE UNITS) SIGNAL STATE BOARD FUNCTI SIGNAL STATE BOARD FUNCTI G FAN INSTANT G Y COMPRESSOR AND OUTDOOR COMPRESSOR AND OUTDOOR FAN INSTANT FAN 60 SECD DELAY DEH MODELS FAN 30 SECD DELAY DEM MODELS W" HEATER BANK (HTR, & 3) INSTANT HEATER BANK (HTR, & 3) INSTANT FAN 0 SECD DELAY G W" HEATER BANK (HTR, & 3) INSTANT HEATER BANK (HTR, & 3) INSTANT FAN 0 SECD DELAY W" HEATER BANK (HTR, & 3) INSTANT HEATER BANK (HTR 4, 5 & 6) 0 SEC. DELAY HEATER BANK (HTR 4, 5 & 6) INSTANT HEATER BANK (HTR, & 3) SEC. DELAY FAN 0 SECD DELAY G W" W" HEATER BANK (HTR, & 3) INSTANT HEATER BANK (HTR 4, 5 & 6) 0 SEC. DELAY HEATER BANK (HTR 4, 5 & 6) SEC. DELAY HEATER BANK (HTR, & 3) SEC. DELAY FAN 0 SECD DELAY W" W" HEATER BANK (HTR, & 3) INSTANT HEATER BANK (HTR 4, 5 & 6) 0 SEC. DELAY HEATER BANK (HTR 4, 5 & 6) SEC. DELAY HEATER BANK (HTR, & 3) SEC. DELAY FAN 0 SECD DELAY SECURE OWNER'S APPROVAL: When the system is functioning properly, secure the owner's approval. Show him the location of all disconnect switches and the thermostat. Teach him how to start and stop the unit and how to adjust temperature settings within the limitations of the system. 4 Unitary Products Group
15 6666-YIM-B-004 NORMAL MAINTENANCE WARNING: Prior to any of the following maintenance procedures, shut off all power to the unit, to avoid personal injury. Periodic maintenance consists of changing or cleaning filters and general cleaning of the outdoor coil. MAINTENANCE OUTDOOR COIL - Dirt should not be allowed to accumulate on the outdoor coil surface or other parts in the air circuit. Cleaning should be as often as necessary to keep the coil clean. Use a brush, vacuum cleaner attachment, or other suitable means. If water is used to clean the coil, be sure that the power to the unit is shut off prior to cleaning. FILTERS - Inspect once a month. Replace Disposable or clean Permanent Type as necessary. DO NOT replace Permanent Type with Disposable. MOTORS - Indoor and outdoor fan motors are permanently lubricated and require no maintenance. CAUTI: Exercise care when cleaning the coil so that the coil fins are not damaged. Do not permit the hot condenser air discharge to be obstructed by overhanging structures or shrubs. WARNING:Troubleshooting of components necessarily requires opening the electrical control box with the power connected to the unit. Use extreme care when working with live circuits! Check the unit nameplate for the correct line voltage and set the volt meter to the correct range before making any connections with line terminal TROUBLESHOOTING CAUTI: The wire number or color and terminal designations referred to may vary. Check the wiring label inside the control box access panel for the correct wiring.. If the variable speed motor found in the DPH048 and DPH060 models operates erratically, check the fan control board for the presence of a c break-off tab. Remove tab if present. Unitary Products Group 5
16 6666-YIM-B-004 NOTES FOR WIRING DIAGRAMS PAGES 6, 7, 8, 9, 0 AND LEGEND FOR WIRING DIAGRAMS PAGES 6, 7, 8, 9, 0 AND -F (NOT USED) - M3, 30V COIL 6 Unitary Products Group
17 6666-YIM-B-004 OPTIAL CCH S / P CFIGURATI CCH BLK L BLK T SEE DETAIL "A" D / P CFIGURATI CCH BLK L BLK L M- T L DETAIL "A" FIG. 7 - TYPICAL WIRING DIAGRAM (08/ POWER SUPPLY) DEH MODELS 5695BASH030 Unitary Products Group 7
18 6666-YIM-B-004 SEE DETAIL OPTIAL CCH "A" S / P CFIGURATI CCH BLK BLK L T D / P CFIGURATI CCH BLK L BLK L M - T L DETAIL "A" 5556BBSH030 FIG. 8 - TYPICAL WIRING DIAGRAM (08/ POWER SUPPLY) DEM MODELS 8 Unitary Products Group
19 6666-YIM-B-004 FIG. 9 - TYPICAL WIRING DIAGRAM (08/ POWER SUPPLY) DEH MODELS Unitary Products Group 9
20 6666-YIM-B-004 FIG. 0 - TYPICAL WIRING DIAGRAM (08/ POWER SUPPLY) DEM MODELS 0 Unitary Products Group
21 6666-YIM-B-004 FIG. - TYPICAL WIRING DIAGRAM ( AND POWER SUPPLY) DEH MODELS Unitary Products Group
22 6666-YIM-B-004 FIG. - TYPICAL WIRING DIAGRAM ( AND POWER SUPPLY) DEM MODELS Unitary Products Group
23 6666-YIM-B-004 Unitary Products Group 3
24 ISO 900 Certified Quality Management System Unitary Products Group 5005 York Drive, Norman, Oklahoma Subject to change without notice. Printed in U.S.A. Copyright 004 by York International Corporation. All Rights Reserved YIM-B-004
Supersedes: N1Y (1099) N1Y (0500) MODELS B1HA018 THRU THRU 5 TON (10 SEER)
CHAMPI SERIES SINGLE PACKAGE HEAT PUMPS INSTALLATI INSTRUCTI Supersedes: 5.8NY (099) 5.8NY (0500) MODELS BHA08 THRU 060.5 THRU 5 T (0 SEER) 0356004 GENERAL YORK Model BHA units are factory assembled heat
More informationINSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)
INSTALLATION MANUAL CONTENTS GENERAL...................................... 3 INSPECTION.................................... 3 INSTALLATION.................................. 3 REFERENCE....................................
More informationSupersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)
CHAMPION SERIES SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.18-N2Y (8) 511.18-N2Y (7) MODELS B1HH018 THRU 00 1.5 THRU 5 TON (12 SEER) 035-1707-000 GENERAL YORK Model B1HH units are
More informationMODELS B1PA024, 030 AND 036
STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat
More informationSupersedes: A-0202 MODELS B1HA018 THRU THRU 5 TON (10 SEER)
CHAMPION SERIES SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 035600400A00 035600400A004 MODELS BHA08 THRU 060.5 THRU 5 TON (0 SEER) GENERAL YORK Model BHA units are factory assembled
More informationR-410A AFFINITY SERIES DEX DEY Ton
R-410A AFFINITY SERIES 024-048 DEY060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations......................................
More informationR-410A AFFINITY SERIES
R-410A AFFINITY SERIES BHZ024-060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations......................................
More informationSUNLINE 2000 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N7Y (993) 530.
SUNLINE 00 ELECTRIC / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: 530.18N7Y (993) 530.18N7Y (295) MODELS D3CE 036, 048 & 060 ( SEER) MODEL D1CE 072 (9 EER) (STYLE B &
More informationSupersedes: N2W (398) N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 208/230/460 VOLT MODELS ONLY
INSTALLATION SINGLE PACKAGE HEAT PUMPS 71/2 & 10 TON INSTRUCTION Supersedes: (398) 511.06N2Z (1298) MODELS BCCB 090 & 120, MODELS BECB090 & 120 (9 EER) 03516199 208/230/460 VOLT MODELS ONLY 208/230/575
More informationINSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BCH 036, 048 & 060
INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BCH 036, 048 & 060 CONTENTS GENERAL................................ 4 SAFETY CONSIDERATIONS................. 4 INSPECTION..............................
More informationSTELLAR 2000 SINGLE PACKAGE AIR CONDITIONERS GAS/ELECTRIC, AIR-COOLED INSTALLATION INSTRUCTION
STELLAR 2000 SINGLE PACKAGE AIR CONDITIONERS GAS/ELECTRIC, AIR-COOLED INSTALLATION INSTRUCTION Supersedes: 530.44-N4Y (893) 530.44-N4Y (1294) MODELS D3GA018 THRU 042 (10 SEER) 035-12496 GENERAL YORK Model
More informationMODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 208/230/575 VOLT MODELS ONLY 208/230/460 VOLT MODELS ONLY
SUNLINE 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.06N2Y (1191) 511.06N2Y (293) MODELS B3CH 090 & 120A25, A46 MODELS B4CH090 & 120A58 (9 EER) 03510256 208/230/460 VOLT MODELS
More informationINSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BP
INSTALLATION MANUAL SUNLINE 2000 SINGLE PACKAGE HEAT PUMP BP 036-072 CONTENTS GENERAL................................ 4 SAFETY CONSIDERATIONS................. 4 INSPECTION..............................
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationMODELS B3CH 048 AND 060 (WORLD 50 HZ)
SUNLINE 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 5.3-NYI (900)/035-2984-000 035-2984-00-A-0204 MODELS B3CH 048 AND 060 (WORLD 50 HZ) GENERAL YORK Model BCH units are single package
More informationINSTALLATION MANUAL CHAMPION PLUS SINGLE PACKAGED GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON
INSTALLATION MANUAL CHAMPION PLUS SINGLE PACKAGED GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 1-1/2 THROUGH 5 NOMINAL TON CONTENTS GENERAL.................................... 3 INSPECTION.................................
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationINSTALLATION MANUAL SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) HB Ton HB Ton HB Ton NOTES, CAUTIONS AND WARNINGS
INSTALLATION MANUAL SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) CONTENTS GENERAL................................... 5 SAFETY CONSIDERATIONS.................... 5 AGENCY APPROVALS.........................
More informationACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72
ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY, 16, 26, 36 & 72 FOR SPLIT-SYSTEM AIR CONDITIONERS 5, 7-1/2, & 15 TONS SPLIT-SYSTEM HEAT PUMPS 7-1/2 & TONS GENERAL This instruction covers the
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationR-410A. DYQ Ton TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES. General
R-410A DYQ024-060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations....................................
More informationINSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGED GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 THROUGH 5 NOMINAL TON DNA:
INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGED GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 THROUGH 5 NOMINAL TON CONTENTS GENERAL.................................... 3 INSPECTION.................................
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION MODULAR AIR HANDLER MODEL: N*AH CONTENTS GENERAL... 1 INSPECTION... 2 REFERENCE... 2 LIMITATIONS... 2 LOCATION... 2 BLOWER/COIL ASSEMBLY UPFLOW AND HORIZONTAL INSTALLATIONS...
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 13CHPX SERIES UNITS PACKAGED HEAT PUMPS (2 5 TONS) 505,136M (38152A071) 12/09 Supersedes 05/09 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation,
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,
More informationSUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES
50.TGY (95) SINGLE PACKAGE COOLED CONDITIONERS DCE 0, 0, 00 & DCE 07 0, 0, 00 & 07, AND 5 NOMINAL TONS (0 SEER) AND NOMINAL TONS (9 EER) SHOWN SUNLINE 000 DESCRIPTION YORK Sunline 000 units are convertible
More informationTECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS SUNLINE 2000ô MODELS: H5CE090, H3CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 9.0-9.5 EER DESCRIPTION These Sunline 2000ô units are completely
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationR-410A AFFINITY SERIES
R-410A AFFINITY SERIES DNZ024-060 2-5 Ton ISO 9001 Certified Quality Management System General.......................................... 1 Installation........................................ 3 Limitations....................................
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationINSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP. MODELS: BA-15 and BA-20. ASHRAE 90.1 Compliant. Model BA-15. Model BA-20
INSTALLATION MANUAL CONTENTS GENERAL....................................4 SAFETY CONSIDERATIONS.....................4 INSPECTION..................................4 REFERENCE..................................4
More informationINSTALLATION MANUAL - 50 Hz
INSTALLATION MANUAL - 50 Hz SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) CONTENTS GENERAL................................... 5 SAFETY CONSIDERATIONS.................... 5 AGENCY APPROVALS.........................
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:
GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant
More informationINSTALLATION MANUAL SUNLINE GAS/ELECTRIC SINGLE PACKAGE AIR CONDITIONERS D(CE, CG) 036, 048, 060 & 072 D(HE, HG) 036, 048 & 060
INSTALLATION MANUAL CONTENTS GENERAL................................ 5 SAFETY CONSIDERATIONS................. 5 INSPECTION.............................. 5 REFERENCE.............................. 6 RENEWAL
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION TABLE OF CONTENTS GENERAL............................. 5 SAFETY CONSIDERATIONS.............. 6 SINGLE PACKAGE HEAT PUMP HIGH EFFICIENCY BP078, 090,102, 120 AND 150 6-1/2 TO 12-1/2
More informationMODELS K2EU060A, K4EU090A, & K3EU120A
AIR COOLED SPLIT-SYSTEM AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: 550.23-N2Y (589) 550.23-N2Y (399) MODELS K2EU060A, K4EU090A, & K3EU120A 035-16672 GENERAL These completely assembled 5, 7-1/2
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationINSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS 15 THROUGH 20 NOMINAL TON HB B-0804
INSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS 15 THROUGH 20 NOMINAL TON CONTENTS GENERAL................................. 3 REFERENCE............................... 3 INSPECTION...............................
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act
More informationINSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS. HB 180 & thru 20 Nominal Tons NOTES, CAUTIONS AND WARNINGS
INSTALLATION MANUAL TABLE OF CONTENTS GENERAL.................................... 3 REFERENCE................................. 3 INSPECTION.................................. 4 OPERATION.................................
More informationINSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER MODEL: LA120 NOTES, CAUTIONS AND WARNINGS SAVE THIS MANUAL B-0203
INSTALLATION MANUAL (AIR COOLED) SPLIT-SYSTEM AIR CONDITIONER CONTENTS NOMENCLATURE............................. 3 GENERAL.................................... 4 SAFETY CONSIDERATIONS.....................
More informationINSTALLATION INSTRUCTIONS
2011 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS 13HPP UNITS PACKAGED HEAT PUMP UNIT (2 5 TONS) 506750 01 06/11 Supersedes 03/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE
More informationProduct Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons
007-014 Single- Package Rooftop Units - 50 Hz 6 to 12 Nominal Tons Product Data Single package rooftop cooling units with electric heat option. Compact, horizontal discharge units (vertical discharge option),
More informationPAR5. Product Specifications
TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced
More informationMODELS W1LC220, 260 AND 320 STYLE B
LIQUID CHILLER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: 570.05-NY (494) 570.05-N3Y (495) MODELS WLC0, 60 AND 30 STYLE B 035-3053 Only -5 and -46 voltage codes GENERAL YORK s WLC Packaged Air-Cooled
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationWeathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS
48HJ-13SB Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationDESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506
TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & 060 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER DESCRIPTION YORK Sunline Ultra units are convertible
More informationSUNLINE 2000 GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: N6Y (593) 530.
SUNLINE 2000 GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: 530.18-N6Y (593) 530.18-N6Y (1294) MODELS D2CG180 & 240 (STY. B) (8.4-8.5 EER) 035-12552 208/230/575 VOLT
More informationR-410A ZS SERIES. 3-6 Ton 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES
R-410A ZS SERIES 3-6 Ton 60 Hertz General.......................................... 2 Installation........................................ 5 Installation Safety Information....................... 5 Limitations......................................
More informationPAJ3. Product Specifications
13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,
More informationPC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]
PC SERIES 50 Hertz Self-Contained Packaged Air Conditioners 4 and 5 Ton [14.1 kw to 17.6 kw] Nominal Cooling Capacity: 48,000 to 60,000 BTUH The PC 50 Hz self-contained packaged air conditioners are designed
More informationELECTRIC / ELECTRIC & GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTRUCTION. Supersedes: N11W (1095) N11W(399)
INSTALLATION ELECTRIC / ELECTRIC & GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS INSTRUCTION Supersedes: 530.18-N11W (1095) 530.18-N11W(399) MODELS DBHB & DBUC300 (8.5 EER) 035-16601 208/230/575 VOLT
More informationConcealed Ducted Split Series R-407C MBH
Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY
More informationMIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/
1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5
More informationMODELS E1FB180 & E1FB240
SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNITS INSTALLATION INSTRUCTION Supersedes: 035-16192-000 (0601) 035-16192-001-A-1001 MODELS E1FB180 & E1FB240 GENERAL The outdoor units are completely piped and wired at
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationSPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION
SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationInstallation Instructions
Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationFLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13
Tag Data - Split System Air Conditioning Units (Large) (Qty: 6) Item Tag(s) Qty Description Model Number A1 20 ton vfd 6 6-25 Ton Unitary Split Systems ( SSC2 TTA24004H00-TWE240E404A TTA Air Condensing
More informationTECHNICAL SPECIFICATIONS
TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the
More informationCROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25
More informationProduct Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:
DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationTECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) LISTED ISO 9001 Certified Quality Management System Due to continuous product
More informationTECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT
TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet
More informationPackaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE
Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature
More informationProduct Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS
Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationEER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER
ENVIRONMENTALLY SOUND REFRIGERANT PA4E Product Specifications 9.2 9.5 EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, 400 3 50 REFRIGERATION CIRCUIT Environmentally sound R 410A refrigerant
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationFLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 AND 4 NOMINAL TON GENERAL
TECHNICAL GUIDE CHAMPION PLUS SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 AND 4 NOMINAL TON D1NP036 and 048 13 SEER FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL YORK s Champion package units are
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationR-410A ZS SERIES. 3-6 Ton 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES
R-410A ZS SERIES 3-6 Ton 60 Hertz General.......................................... 2 Installation........................................ 5 Installation Safety Information....................... 5 Limitations......................................
More informationProduct Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:
PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230
More informationFLEXIBLE LIGHT COMMERCIAL UNIT TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 THROUGH 5 NOMINAL TON GENERAL
FLEXIBLE LIGHT COMMERCIAL UNIT GENERAL TECHNICAL GUIDE AFFINITY SERIES SINGLE PACKAGE GAS/ELECTRIC AIR COOLED AIR CONDITIONERS 3 THROUGH 5 NOMINAL TON DNA036 THROUGH 060 10 SEER York Affinity Series packaged
More informationINSTALLATION INSTRUCTION Supersedes: N11Y (195) N11Y (399)
SUNLINE 2000 ELECTRIC / ELECTRIC & GAS / ELECTRIC SINGLE PACKAGE AIR CONDITIONERS (Constant Air Volume) INSTALLATION INSTRUCTION Supersedes: 530.18-N11Y (195) 530.18-N11Y (399) MODELS D2CE & D2CG300 (8.5
More informationTECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION
TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) LISTED MODELS: 018-060 (3 PH) MODELS: 076 (3 PH) ISO 9001 Certified Quality
More informationProduct Data. Fig. 1 - Unit 50VR -A
50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged
More informationTECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)
TECHNICAL GUIDE VARIALE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: N1VS 600-2000 CFM LOWERS 2-5 TON COILS OPTIONAL 1 & 3 φ ELECTRIC HEATERS ISO 9001 Certified Quality Management
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 001 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationProduct Data. FH4A Fan Unit. Sizes 001 thru 004
Product Data FH4A Fan Unit Sizes 00 thru 004 Air Handling Technology At Its Finest Reliability, dependability, and great value are built into the FH4A fan units. The unit is compact and easy to install,
More informationSUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION
SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTION Supersedes: Nothing 530.25-N3Y (394) MODELS D*SC360 & 480 035-11820 208/230/575 VOLT ONLY 208/230/460 VOLT ONLY GENERAL This instruction
More informationRooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION
PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS 3HPP / rhp3 Rooftop Units 60HZ Bulletin No. 0634 October 04 Supersedes October 0 MODEL NUMBER IDENTIFICATION -PHASE MODELS Nominal SEER (3HPP Shown) Unit Type
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationRGE 13 A T - 1 A
PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE
More informationCHAMPION SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: N4 (778) N4Y (492)
CHAMPION SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: 550.13-N4 (778) 550.13-N4Y (492) MODELS H2CA480 & 600 035-09563 GENERAL CHAMPION units are designed for outdoor
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More informationR-410A MODELS: YD360 Thru Ton 60 Hertz
R-410A MODELS: YD360 Thru 600 30-50 Ton 60 Hertz Nomenclature..................................... 2 General.......................................... 2 Renewal Parts.....................................
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationInstallation Instructions
Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2
More information