Enthalpy Efficiency[%] Efficiency [%] L M H L M H L M H L M H L M H L M H ,

Size: px
Start display at page:

Download "Enthalpy Efficiency[%] Efficiency [%] L M H L M H L M H L M H L M H L M H ,"

Transcription

1 ERGO Download lnorcm uy via 2 uxiliary Equipment and ccessories Heat and energy recovery ventilator ERGO has high efficient counter flow heat exchanger. Total heat exchanger is made of ER paper which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. The clearance between the fibers is very small, so only the moisture molecules of small diameter can go through, the odor molecules of larger diameter are unable to pass through it. y this means, the temperature and humidity can be recovered smoothly, and prevent the pollutants infiltrating to the fresh air. ERGO has 3 speeds, double filters. irflow from 250m3/h to 1000m3/h. Product code: HRU - ERGO type D E O 5 C E - exhaust air O - outdoor air R - room air S - supply air E R S F G M I Model ir flow [m3/h] External pressure [Pa] Enthalpy Efficiency[%] Summer Winter Temp. Efficiency [%] Noise [d] Voltage [V] Current [] Rated Power [W] Wei ght [kg] M H M H M H M H M H M H ERGO-250 ERGO-350 ERGO-500 ERGO-650 ERGO-800 ERGO , , , , , , first gear M - second gear H - third gear

2 ERGO Download lnorcm uy via 2 Model ERGO-250 C D E F G I ERGO ERGO ERGO ERGO ERGO ERGO Technical data Charts M ERGO-350 uxiliary Equipment and ccessories II I II I

3 ERGO Download lnorcm uy via 2 uxiliary Equipment and ccessories Technical data Charts ERGO-500 III bieg II bieg I bieg ERGO-800 ERGO-650 II I ERGO-1000 II II I I

4 ECCO Download lnorcm uy via 2 Heat and energy recovery ventilator ECCO has high efficient cross flow heat exchanger. Total heat exchanger is made of ER paper which is featured by high moisture permeability, good air tightness, excellent tear resistance, and aging resistance. The clearance between the fibers is very small, so only the moisture molecules of small diameter can go through, the odor molecules of larger diameter are unable to pass through it. y this means, the temperature and humidity can be recovered smoothly, and prevent the pollutants infiltrating to the fresh air. ECCO has 3 speeds, double filters. irflow from 200m3/h to 400m3/h. Product code: HRU - ECCO typ D E O 5 C E - exhaust air O - outdoor air R - room air S - supply air Model E C R S F G M ECCO ECCO D E F G I I M uxiliary Equipment and ccessories ECCO Model ir flow [m3/h] External pressure [Pa] Enthalpy Efficiency[%] Summer Winter Temp. Efficiency [%] Noise [d] M H M H M H M H M H M H Voltage [V] Current [] Rated Power [W] Wei ght [kg] ECCO-200 ECCO-300 ECCO , , , first gear M - second gear H - third gear

5 ECCO Download lnorcm uy via 2 uxiliary Equipment and ccessories Technical data Charts ECCO-200 ECCO-400 I II ECCO-300 II I I II

6 Controler CONTR Download lnorcm uy via 2 CONTR controller is a panel with posibility to control the operation of heat and energy recovery unit. CONTR controller allows, among others programming the timer. Heat and energy recovery unit is connected via a standard cable length of 5 meters. Product code: CONTR type power supply N uxiliary Equipment and ccessories bypass black white blue yellow supply air fan black white blue yellow ports reserved exhaust fan black white blue yellow sensor ports tin the tip should be included in the port, the order invalid temp. S temp. E temp. O temp. R cable connection control panel

7 Counterflow heat exchanger HRE-ERGO Download lnorcm uy via 2 uxiliary Equipment and ccessories Counterflow heat exchanger HRE-ERGO is used for ERGO recuperators. Heat exchanger is made of paper with a high moisture permeability, good sealing and good resistance to aging. The distance between the fibers of the cellulose particle size corresponds to the moisture. arger molecules such as fragrances are nieprzepuszczane through the heat exchanger. This prevents the penetration of pollutants into the air. Product code: HRE - ERGO type HRE-ERGO HRE-ERGO HRE-ERGO HRE-ERGO HRE-ERGO HRE-ERGO

8 Crossflow heat exchanger HRE-ECCO Download lnorcm uy via 2 Crossflow heat exchanger ECCO is used for ECCO recuperators. Heat exchanger is made of paper with a high moisture permeability, good sealing and good resistance to aging. The distance between the fibers of the cellulose particle size corresponds to the moisture. arger molecules such as fragrances are nieprzepuszczane through the heat exchanger. This prevents the penetration of pollutants into the air. Product code: HRE - ECCO type HRE-ECCO HRE-ECCO HRE-ECCO uxiliary Equipment and ccessories

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV Inspir Compact Heat and Energy Recovery Multi-Family HRV/ERV High-Profile Performance & Low-Profile Design Small spaces demand smart technology. Aldes Inspir Compact Heat and Energy Recovery Ventilators

More information

Auxiliary Equipment and Accessories

Auxiliary Equipment and Accessories http://www.ventilation-alnor.co.uk/index/products_en/heat-recovery-%e2%80%93-air-handling-units/ Description is recommended for use in residential houses with max. area of 200m2. The most important key

More information

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1 Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

HRV Brochure. Heat Recovery Ventilation

HRV Brochure. Heat Recovery Ventilation HRV Brochure Heat Recovery Ventilation The Importance of Ventilation In todays hi tech world, ventilation is more important than ever before. Gone are the days when we relied on natural ventilation with

More information

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic

More information

HOYME CONTROLS

HOYME CONTROLS INDEX HAC SERIES UNIVERSAL INLINE DAMPERS HANSEN MOTOR DRIVE... 7-5 UNIVERSAL AIR CONTROL... 7-2 7-5 HOM SERIES FRESH AIR DAMPERS COMBUSTION AIR CONTROL... 7-6 COMMERCIAL APPLICATIONS (WHERE BTUs EXCEED

More information

Munters Heat Exchangers

Munters Heat Exchangers Munters Heat Exchangers Brad Perdew Applications Engineer 8/27/12 DOAS Configurations Cheryl Hughes Regional Sales Manager October 11, 2016 cheryl.hughes@munters.com Munters DOAS Configurations Presentation

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

Beijing Holtop Artificial Environment Technology Co., Ltd

Beijing Holtop Artificial Environment Technology Co., Ltd Heat recovery ventilators Energy recovery ventilators Rotary heat exchangers Air handling units Beijing Holtop Artificial Environment Technology Co., Ltd ISO9001:2000 Approved company ENERGY RECOVERY VENTILATION

More information

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company COMPANY BRIEF INTRODUCTION

More information

Home Performance Science

Home Performance Science Home Performance Science Symptoms of a Sick House Too hot/too cold rooms Respiratory problems Headaches/nausea Smoky fireplace Foggy windows Stuffy air and lingering odors Peeling paint Constant dust problems

More information

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure. Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants

More information

Zehnder Comfosystems. ComfoAir 180 Datasheet

Zehnder Comfosystems. ComfoAir 180 Datasheet Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2. RANGE HOODS ATTIC VENTILATORS AIR EXCHANGERS DELUXE RANGE HOODS For more than 25 years, Venmar Ventilation has been one of North America s leading manufacturers of innovative Indoor Air Quality products

More information

Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow. Building Science. Adventures In Building Science. presented by

Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow. Building Science. Adventures In Building Science. presented by Joseph Lstiburek, Ph.D., P.Eng, ASHRAE Fellow Building Science Adventures In Building Science presented by www.buildingscience.com Build Tight - Ventilate Right 2 Build Tight - Ventilate Right How Tight?

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 800 m /h COMFORT 00 Product description The Comfort 00 is an energy-efficient ventilation

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Part #461006 Indirect Gas-Fired Furnaces Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

DES CHAMPS PRODUCTS 85% 4,400 CFM

DES CHAMPS PRODUCTS 85% 4,400 CFM DES CHAMPS PRODUCTS Saves up to 85% of the heat from exhaust airstream Removes pollutants before they accumulate Transfers heat energy in winter/cool energy in summer Low cost Capacities up to 4,400 CFM

More information

ComfoAir Q. Mechanical Ventilation and Heat Recovery

ComfoAir Q. Mechanical Ventilation and Heat Recovery ComfoAir Q Mechanical Ventilation and Heat Recovery 2 MVHR by OMNIE Optimum indoor ventilation The ComfoAir Q from OMNIE is the NEW generation of heat recovery ventilation units, with state of the art

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

Heat and energy recovery ventilators

Heat and energy recovery ventilators Description is recommended for use in residential houses with max. area of 200m2. The most important key features of : Heat recovery up to 95% according to EN 308 - TUV SUD Plastic counterflow heat exchanger

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates Creating an Energy-Chic Home The Highgate Society, 8 February 2017 No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates www.rickabythompson.com No Taxation Without Representation

More information

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h PRODUCT DATA COMFORT 5000 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 5300 m 3 /h COMFORT 5000 The Comfort 5000 is a ventilation unit suitable for central

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode) LOSSNAY LINE-UP Application 2 6 8 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST THE TRADITIONAL HEAT RECOVERY COIL SYSTEM SHALL BE UPDATED TO COME UP TO REQUIREMENTS OF THE ECODIRECTIVE. HIGH EFFICIENCY UNDER LOW OPERATING TEMPERATURE DEMANDS A NEW IMPROVED CONCEPT TO PREVENT FREEZING

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

Ventilation systems. Indoor air quality for inner well-being

Ventilation systems. Indoor air quality for inner well-being Ventilation systems Indoor air quality for inner well-being Why (controlled) ventilation? With increasing pressure from Building Regulation Part F (adequate ventilation) and Part L (energy conservation),

More information

Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted.

Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted. Breathe Balanced Easy With The best solutions provide fresh the whole Out Bad -only ventilation uses a relatively low-volume bathroom fan run either continuously or at intervals on a timer to expel stale

More information

ERVB ENERGY RECOVERY VENTILATORS. Form No. PDS ERV.64.1

ERVB ENERGY RECOVERY VENTILATORS. Form No. PDS ERV.64.1 ENERGY RECOVERY VENTILATORS ERVB The Energy Recovery Ventilator (ERV) offered by Bryant is the finest unit on the market today. The ERVB provides efficient and cost-effective heat recovery when needed

More information

A whole lot of fresh.

A whole lot of fresh. Indoor Air Quality A whole lot of fresh. Trane FreshEffects Energy Recovery Ventilator provides a whole-house solution for fresh air ventilation. Trane FreshEffects exhausts stale indoor air and brings

More information

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual RETIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Part # 461006 MODEL PVF INDIRECT GS FIRED FURNCES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual Model PVF, Indirect Gas Furnace,

More information

Breathe Fresh Air at Home

Breathe Fresh Air at Home Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans Breathe Fresh Air at Home Residential Ventilation 2 Category name / Registername

More information

Ventilation & Heat Recovery. The whole house system from OMNIE

Ventilation & Heat Recovery. The whole house system from OMNIE Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit Heat Recovery Ventilation Unit IGH FX / IGH FX EC has been designed to provide energy saving by recovery through heat energy exchangers. IGH FX / IGH FX EC is used in order to increase the quality of interior

More information

Heat Recovery Ventilator

Heat Recovery Ventilator REKUPETORI Heat Recovery Ventilator Heat recovery ventilator Larger air supply rate enhanced heat exchange efficiency enhanced energy saving property The heat recovery ventilator (HRV) can reclaim heat

More information

Residential ventilation concepts based on the idea of displacement airflow distribution

Residential ventilation concepts based on the idea of displacement airflow distribution A strategy for reducing energy demand Student: Aris Gkitzias (I.D:4180380) Mentors: Dr. Regina Bokel, Ir. John van der Vliet MSc graduation project Department of Building Technology, faculty of architecture

More information

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation

More information

DOMEKT. Residential ventilation units

DOMEKT. Residential ventilation units OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

Zehnder ComfoAir 550. Ventilation unit

Zehnder ComfoAir 550. Ventilation unit Use The ventilation unit was specially developed for use in residential and commercial buildings with high ventilation demand. It combines maximum comfort, simple operation and high efficiency with flexible

More information

Dee Fly Cube 300 and 370. Heat Recovery ventilation

Dee Fly Cube 300 and 370. Heat Recovery ventilation V E N T I L A T I O N Dee Fly Cube 300 and 370 Heat Recovery ventilation 2 Simple and streamlined design Perfect integration in dwelling The principle of heat recovery ventilation Heat recovery ventilation

More information

HRV Enthalpy. Catalogue

HRV Enthalpy. Catalogue HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts A highly efficient Enclosure is Key Maximize Solar Gain Minimum Insulation Values Walls R-65 Roof R-90 Slab R-60 No Thermal Bridging! 0.6 ACH_50 or better The Building is always the sum of ALL it s parts

More information

XB-EFA-8L-BK & XB-EFA-8R-BK

XB-EFA-8L-BK & XB-EFA-8R-BK Supply & Extract Ventilation Unit with Heat Recovery The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU The information contained in this document provides details of installation, operation

More information

Heat Recovery Ventilators models:

Heat Recovery Ventilators models: User s Manual Read and save these instructions. Heat Recovery Ventilators models: 1000 HE 2000 HE 3000 HE 3055 Compact HE 1.3 HE 1.8 HE 2.6 5585 Compact VB0021 VVI, 550 Lemire Blvd., Drummondville, Qc,

More information

Compact Filter Unit Type CFU

Compact Filter Unit Type CFU Compact Filter Unit Type CFU 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344 e-mail: info@ltg-inc.net Internet: http://www.ltg-inc.net

More information

Designing Energy Efficient Outdoor Air Systems

Designing Energy Efficient Outdoor Air Systems Designing Energy Efficient Outdoor Air Systems Joseph Thorndal Applied Products Sales Manager Greenheck, Schofield, Wisconsin 1 Joseph Thorndal BS Industrial Engineering North Dakota State University Work

More information

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9 ERV/ HRV CONTENTS Horizontal rotor heat recovery ventilation unit RH 5 Vertical rotor heat recovery ventilation unit RV 9 Suspended plate heat recovery ventilation unit CFP Horizontal plate heat recovery

More information

Product Data HRV A10299

Product Data HRV A10299 HRVCCLHA Heat Recovery Ventilator ERVCCLHA Energy Recovery Ventilator Product Data A10299 The Heat Recovery Ventilation (HRV) and Energy Recovery Ventilator (ERV) systems offered by Carrier are the finest

More information

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz

More information

EU Air Handling Units with SEMCO EXCLU-SIEVE

EU Air Handling Units with SEMCO EXCLU-SIEVE EU Air Handling Units with SEMCO EXCLU-SIEVE The acquisition of US based Semco has given us the opportunity to include a new range of rotary heat exchangers in our EU air handling unit range. Hygienic

More information

Air to Air Heat Exchanger

Air to Air Heat Exchanger Air to Air Heat Exchanger VN-M1HE / VN-M2HE VN-M3HE / VN-MHE VN-M6HE / VN-M8HE VN-M1HE VN-M1HE VN-M2HE Air to Air Heat Exchanger MMD VN2HEXE MMD VN82HEXE MMD VN12HEXE with DX-coil Type CONTENTS 1. Specifications

More information

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h PRODUCT DATA COMFORT 300 TOP BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 325 m 3 /h COMFORT 300 TOP Product description The Comfort 300 Top is an energy-efficient

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 450 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 450 m 3 /h COMFORT 450 Product description The Comfort 450 is an energy-efficient ventilation

More information

ENERGY RECOVERY VENTILATOR

ENERGY RECOVERY VENTILATOR ENERGY RECOVERY VENTILATOR ERV 60H Part no. 606 (TOP PORTS) Part no. 60 (SIDE PORTS) 5 to 05 CFM (0. in. w.g.) VB0073 AN INGENIOUS AIR EXCHANGE SOLUTION THAT S AS VERSATILE AS IT IS COMPACT! Configured

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden Efficient energy recovery in AHU DOHA, Qatar 11.04.2010 Timo Schreck Enventus AB, Sweden Main principles for cooling and dehumidification process in AHU 1. With cooling coil and reheater 2. Energy recovery

More information

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group State of MN Energy Code Ventilation Review for 2017 Energy Design Conference By 1. Mike D. Wilson Dakota Supply Group In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11,

More information

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR INSTALLATION INSTRUCTIONS Models: ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR For Use with Bard 2 Thru 5 Ton "P" Series Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan,

More information

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 15 TOP M2 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 400 m 3 /h Comfort heating Comfort cooling VPL 15 TOP M2 Product description VPL 15 Top

More information

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed) 27 SYSTEM LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E

More information

Residential Heat & Energy Recovery

Residential Heat & Energy Recovery Residential Heat & Energy Recovery Aeromatic Series Standard Residential HRV/ERV 95-215 CFM 2 Discover Heat & Energy Recovery A tightly built, high-performance home is a great way to conserve energy and

More information

Topvex SX/C, Topvex TX/C Air Handling Unit

Topvex SX/C, Topvex TX/C Air Handling Unit Topvex SX/C, Topvex TX/C Air Handling Unit Operation and Maintenance Instructions Document in original language 131678 A003 GB Contents 1 Warnings...1 2 Product Description...2 2.1 Internal components...2

More information

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro

More information

MASS AND HEAT RECOVERY SYSTEM SALAH MAHMOUD HINDAWI DIRECTOR HINDAWI FOR ENGINEERING SERVICES & CONTRACTING NEW DAMIETTA, EGYPT

MASS AND HEAT RECOVERY SYSTEM SALAH MAHMOUD HINDAWI DIRECTOR HINDAWI FOR ENGINEERING SERVICES & CONTRACTING NEW DAMIETTA, EGYPT ESL-IC-10-10-56 MASS AND HEAT RECOVERY SYSTEM SALAH MAHMOUD HINDAWI DIRECTOR HINDAWI FOR ENGINEERING SERVICES & CONTRACTING NEW DAMIETTA, EGYPT ABSTRACT : In the last few years heat recovery was under

More information

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2

More information

VERSO Air Handling Units

VERSO Air Handling Units VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO Air Handling Units VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P

More information

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with

More information

Energy Recovery Ventilator

Energy Recovery Ventilator Energy Recovery Ventilator LG Electronics www.lg.com http://partner.lge.com Distributed by Copyright 2015 LG Electronics. All rights reserved. 2015 Eco_V Energy Recovery Ventilator Heat Exchanger Bypass

More information

STAS SERIES SELECTRONIC ALARM ANNUNCIATORS

STAS SERIES SELECTRONIC ALARM ANNUNCIATORS STS-90N Revised 07-0 Section (00-0-089) STS SERIES SELECTRONIC LRM NNUNCITORS DESIGN, INSTLLTION ND OPERTING MNUL CLL MURCL TO PLCE YOUR ORDER MurCal www.murcal.com P:(66)7-700 F:(66)97-770 e-mail: sales@murcal.com

More information

Tech to Tech May 07 HRV s & ERV s

Tech to Tech May 07 HRV s & ERV s Tech to Tech May 07 HRV s & ERV s Make daily deposits to your box of knowledge, soon it will have many reference cards. --Randal S. Ripley With the cost of energy going up all the time, home owners and

More information

Total Heat Exchanger GAE-50D GAE-80D GAE-100D GAE-150D GAE-400D GAE-350D GAE-500D

Total Heat Exchanger GAE-50D GAE-80D GAE-100D GAE-150D GAE-400D GAE-350D GAE-500D Total Heat Exchanger GAE-15D GAE-25D GAE-35D GAE-50D GAE-80D GAE-100D GAE-150D GAE-250D GAE-350D GAE-500D GAE-200D GAE-300D GAE-400D Thank you for choosing our Total Heat Exchanger. Please read this USER

More information

OA Processing unit GUF-RD4, GUF-RDH4

OA Processing unit GUF-RD4, GUF-RDH4 Processing unit DT G GUFRD4, GUFRDH4 I. Processing unit. SPEIFITIOS... 27 2. SOUD EVES... 28 2. Measurement ondition... 28 22. curves... 28. F HRTERISTIS URVES... 29 4. EXTER DIMESIOS... 240 5. EETRI WIRIG

More information

HRU-MinistAir-W-450. Elementy dachowe. Heat recovery units. Dimensions. Description. Control. ALNOR systemy wentylacji

HRU-MinistAir-W-450. Elementy dachowe. Heat recovery units. Dimensions. Description. Control. ALNOR systemy wentylacji Heat recovery units -W-450 Dimensions 160 710 725 797 Elementy dachowe Description The -W-450 heat recovery unit is designed for single-family houses up to 200 m 2 in usable floor area. 610 630 Key performance

More information

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling. PRODUCT DATA VPL 28 BY NILAN Ventilation & active heat recovery Domestic Active heat recovery Ventilation < 1000 m 3 /h Comfort heating Comfort cooling VPL 28 Product description VPL 28 is an energy-efficient

More information

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Heat Recovery Ventilation Systems Data Sheet PA600LI The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications Houses ranging in size from 100 300 M2

More information

PRODUCT RANGE: ROOFTOP PACKAGE

PRODUCT RANGE: ROOFTOP PACKAGE Packaged Air Cooled Reverse Cycle Type Air Conditioner Range 11-125kWr With Energy / Heat Recovery The Roof Top Packaged unit range is designed to be used when high fresh air quantities are required. They

More information

Energy recovery unit. Projection documents

Energy recovery unit. Projection documents Energy recovery unit Projection documents 1. Technical charakteristics 1.1. Function and uses The energy recovery unit Futura is a device designed for controlled ventilation and interior adjustment of

More information

220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP OPERATION MANUAL

220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP OPERATION MANUAL 220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP OPERATION MANUAL 220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP MANUAL F-1H-01SS 1 TABLE OF CONTENTS I. II. III. IV. V. Important safety Information

More information

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER Journal of Ecological Engineering Volume 17, Issue 5, Nov. 2016, pages 163 172 DOI: 10.12911/22998993/65466 Research Article VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER Vyacheslav Pisarev 1, Sławomir

More information

Ventilation Solutions IAQ Canada

Ventilation Solutions IAQ Canada Ventilation Solutions IAQ Canada 2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines.

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs Custom Units to Meet Your Unique Design Needs Engineered for flexibility and performance Contents Horizontal Configuration....1 Horizontal with Standard Economizer Configuration...2 Stacked Configuration...3

More information

Convection Rework Made Easy

Convection Rework Made Easy Convection Rework System Convection Rework Made Easy The Convection Rework System combines sophisticated process control and wide-ranging capabilities with a user-friendly, ergonomic design to speed and

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-09 QWSERV with Occupied Air Capabilities For Use With Bard Through Ton QW*S Series Bard Manufacturing Company, Inc. Bryan, Ohio

More information

Heat Exchanger Earny Type

Heat Exchanger Earny Type Big Dutchman International GmbH Heat Exchanger Earny Type 4. Efficiency of heat recovery under practical conditions DLG Test Report 614 F Revision 1: Amendment(s) see page 1 Assessment summary The DLG

More information

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction: Refrigeration Systems Theoretical hours: 2 Practical hours: 2 Units: 6 COOLING TOWERS First 10 minutes: review the last lecture. Then explain the new lecture, solve an example. Last 10 minutes review the

More information