VRV systems. Superior heating under low temperature conditions

Size: px
Start display at page:

Download "VRV systems. Superior heating under low temperature conditions"

Transcription

1 VRV systems Superior heating under low temperature conditions

2 ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning equipment for industrial, coercial and residential use. Daikin Europe N.V. ENVIRONMENTAL AWARENESS Air Conditioning and the Environment Air conditioning systems provide a significant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested enormous efforts in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significant contribution to limiting the impact on the environment. 2

3 TABLE OF CONTENTS INTRODUCTION ON VRV III-C 4 Features 5 1. Wide Application Range 5 2. High comfort levels Environmental Awareness installation & Maintenance Friendly Design 14 Outdoor Units VRV III-C TECHNOLOGY specifications Accessories 23 Indoor Units Features Specifications & Accessories 31 Ventilation HRV-Heat Reclaim Ventilation FXMQ-MFV1 - Outdoor Air Processing Unit VRV +EXV-kit - VRV Air Handling Applications 47 Powerful Selection Prograes VRV Xpress VRV pro 49 User Friendly Control Systems Individual Control Systems Centralised Control Systems Network Solutions Accessories 58 3

4 > newly developed 2-stage Compression technology > powerful heating even in Cold climates > enhanced Comfort through quick-start heating > higher COP under low temperature conditions > Cuts defrosting time INTRODUCTION ON VRV III-C Daikin Europe has extended its range of VRV air conditioning systems with the technologically advanced VRV III-C inverter controlled heat pump system, designed specifically for installation in colder climates. Available in 10, 14, 16 and 20HP versions, VRV III-C is the first heat pump system on the market able to provide year round heating in outdoor temperatures down to -25 C without the need for any supplementary heating. In low ambient conditions, VRV III-C offers 30% more heating capacity compared to a standard VRV III heat pump.* Cooling is also available in ambient temperatures down to -5 C. System heating is extremely stable a 10HP system for example, operating in an ambient of -10 C, has a capacity reduction ratio of just 11%. less than 50% of that of a standard VRV III heat pump of comparable size.* VRV III-C comprises a newly designed outdoor unit and function unit, featuring two stage compression technology, which provides its outstanding performance characteristics by creating the higher pressures necessary for efficient operation under low ambient conditions. Energy saving potential is excellent with a COP at -10 C of over 3.0 for all models, with rapid heat up to 40 C discharge temperature at low ambient achievable in only 8 minutes. Also, the short defrost cycle of 4 minutes ensures a more stable interior temperature, resulting in considerably improved comfort levels. Performance figures such as these lead to annual power costs around 20% lower than those of VRV III HP models. The system can be linked to the complete range of Daikin ceiling mounted, concealed, ducted, corner, cassette, wall mounted and floor mounted indoor fan coil units. 4 * Field test data Akita city 06/Jan, Japan

5 Features 1. Wide Application Range RTSYQ10PY1 RTSYQ20PY1 1. VRV III-C Outdoor Unit Range VRVIII - C N of outdoor units N of compressors Maximum n of connectable indoor units Minimum capacity index - 50% Maximum capacity index - 130% * RTSYQ10PY1 1 + function unit RTSYQ14PY1 1 + function unit RTSYQ16PY1 1 + function unit RTSYQ20PY1 2 + function unit * Please contact you local dealer for more information 2. Indoor Unit Capacity Index Model Capacity index eg. Selected indoor units: FXCQ25 + FXFQ100 + FXMQ200 + FXSQ40 + FXFQ40 Connection ratio: = 405 > possible outdoor unit RTSYQ16PY1 5

6 features wide application range 3. Wide Range of Indoor Units VRV air conditioning brings suer freshness and winter warmth to offices, hotels, department stores and many other coercial premises. It enhances the indoor environment and creates a basis for increased business prosperity and whatever the air conditioning requirement, a Daikin indoor unit will provide the answer. VRV air conditioning can be supplied via 13 DIFFERENT INDOOR UNIT MODELS in a total of 75 VARIATIONS. Roundflow ceiling mounted cassette 2-way blow ceiling mounted cassette 4-way blow ceiling mounted cassette Small concealed ceiling unit Ceiling mounted corner cassette Slim concealed ceiling unit 6

7 Indoor units NEW Roundflow ceiling mounted cassette 4-way blow ceiling mounted cassette 2-way blow ceiling mounted cassette Ceiling mounted corner cassette Small concealed ceiling unit Slim concealed ceiling unit Concealed ceiling unit Concealed ceiling unit Wall mounted unit Ceiling suspended unit 4-way blow ceiling suspended unit Floor standing unit Concealed floor standing unit FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ FXSQ FXMQ FXAQ FXHQ FXUQ FXLQ FXNQ Concealed ceiling unit Wall mounted unit Concealed ceiling unit 4-way blow ceiling suspended unit Ceiling suspended unit (Concealed) Floor Standing Unit 7

8 features wide application range 4. Integrated ventilation Daikin offers a variety of solutions for the provision of fresh air ventilation to offices, hotels, stores and other coercial outlets each one complementary to and as flexible as the VRV system itself. HRV - Heat Reclaim Ventilation Heat and humidity are exchanged between supply and exhaust air, which - Brings outdoor air close to indoor air conditions - Recovers energy loss - Realises considerable reduction of air conditioning capacity. The heat exchanger modulates the humidity and temperature of incoming fresh air to match indoor conditions. The cooling/heating load placed on the air conditioning system is reduced. (Heat and humidity are exchanged). Most energy saving solution as smaller indoor units can be selected: - Size down of indoor units down to 40 % - Payback total VAM system: ±2.5 years* *conditions: - outside cooling conditions: 30 C / outside heating conditions: - 8 C - Inside cooling conditions: 24 C / inside heating conditions: 22 C - Ventilation per room: 150m 3 /h Ideal modular concept to cope with the fresh air requirements FXMQ-MFV1 Outdoor Air Processing Unit 100% fresh air intake possible Leaves maximum floor and wall space for furniture, decorations and fittings Operation range: -5 C to 43 C 225 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Drain pump kit available as accessory 8

9 5. STABLE heating capacity VRV III-C has a stable heating capacity, even in low ambients, making it suitable for single source heating. The heating capacity is 130% in comparison with the standard VRV III heating capacity under similar conditions () Heating capacity 10HP outdoor unit standard heat pump Outdoor temp. ( CWB) operation range HEATING COOLING 6. WIDE HEATING OPERATION RANGE VRV III-C is the first system on the market with a standard operation range down to -25 C outdoor ambient in heating and can also provide cooling down to - 5 C outdoor ambient outdoor temperature VRV III-C CDB -25 CDB VRV III CDB -20 CDB VRV III -C +43 CWB VRV III +43 CWB -5 CWB -5 CWB 7. Flexible piping design VRV III-C offers an extended piping length of 165m (190m equivalent piping length) with a total system piping length of 500m. Actual piping length 165 m Equivalent piping length 190 m If the outdoor unit is located above the indoor unit, the height difference is 50m. If the outdoor unit is located below the indoor unit, the height difference is 40m. The distance between the outdoor unit and the function unit should be a maximum of 10m (13m equivalent piping length). 165m Actual piping length 50m Level difference between indoor and outdoor units 15m Level difference between indoor units 90m maximum After the first branch, the difference between the longest piping length and the shortest piping length can be a maximum 40m, provided that the longest piping length amounts to a maximum of 90m. 9

10 features wide application range 8. Super silent operation Outdoor Units Quietness is another important feature. To reduce noise and ensure comfortable operation, the latest technologies and features have been applied to the outdoor units. Night quiet function (max. -8dBA) Peak in the outdoor temperature Capacity* % Operation Sound dba 8 hrs 9 hrs Max. -8dB (10 HP) Notes: This function is available for on site setting. the relationship between outdoor temperature (load) and time shown in the graph is merely an example. Night mode starts Night mode ends During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and ending time can be input 2 modes (*1) with low sound level at night: Mode 1 Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours (*2) after the peak temperature in the daytime and operation will return to normal after 9 hours (*3). Mode 2 Customized mode Starting and ending times can be input. (External control adapter for outdoor unit, DTA104A61 or DTA104A62 and a separately ordered timer are necessary.) Notes: (*1). Determine which mode to select depending on the climatic characteristics of each country. (*2). Initial setting. Can be selected from 6, 8 and 10 hours. (*3). Initial setting. Can be selected from 8, 9 and 10 hours. 10 Indoor Units Daikin indoor units operate at sound levels as low as 25 dba db(a) Perceived loudness Sound 0 Treshold of hearing - 20 Extremely soft Rustling leaves 40 Very soft Quiet room 60 Moderately loud Normal conversation 80 Very loud City traffic noise 100 Extremely loud Symphonic orchestra 120 Threshold of feeling Jet taking off Daikin indoor units

11 2. High comfort levels 1. High heat up speed Heat up speed is dramatically reduced, particularly under low ambient conditions. The required time for discharge temperature to reach 40 C has been reduced by 50%. Start heating operation Indoor heat exchanger temperature VRV III-C 50 Indoor temperature VRV III-C Indoor heat exchanger temperature standard heat pump Indoor temperature standard heat pump Discharge temperature ( C) Standard heat pump Indoor temperature C % REDUCTION Elapsed time (min.) * Field test data in Japan with 14 HP unit (Akita City Jan 2006) 2. Short defrost time The time required for defrost is reduced to 4 minutes less than half that of the standard VRV III system (10 minutes), leading to a more stable interior indoor temperature and considerably improved comfort levels. * Field test data in Japan with 10 HP unit (Akita City Jan 2006) 11

12 3. Environmental Awareness 1. High COP (VRV III -C) The use of two stage compression technology results in improved energy saving performance at low ambients, with a COP of more than 3.0 at -10 C outdoor ambient. Annual power costs are therefore, considerably lower than those of the standard heat pump. COP COP (10HP) Standard VRVIII heat pump Outdoor temp. (WB ) 12

13 2. Inverter Technology The linear VRV system makes use of a Variable Proportional Integral (PI) control system, which uses refrigerant pressure sensors to provide added control over inverter and ON/OFF control compressors. This reduces the control steps into smaller units, providing precise control in both small and larger areas. Energy efficiency is also higher under part load conditions. Since less capacity is required, the compressor rotates more slowly and the coil becomes virtually oversized. Superior efficiencies can therefore, be achieved with inverter compressors, rather than with non inverter compressors, which always run at the same speed. T Slow start Temperature remains stable Air conditioning with Inverter Air conditioning without Inverter t 3. Less Frequent Start/Stop Cycle The technique adopted by Daikin, of regulating the capacity using multiple compressors clearly results in minimum switching losses and power surges because of the overlap in capacity and frequency Since Daikin utilises small 5HP inverter compressors, the influence of harmonics is less than that generated by a single large compressor The use of multiple compressors by Daikin also ensures a 50 % standby facility Smaller compressors are cheaper and faster to replace Capacity 60% 65% 50% 55% on 116+on Frequency 13

14 features 4. Installation & Maintenance Friendly Design 1. Automatic Charge Function Conventional Way: 1. calculation of additional refrigerant charging volume 2. charging the unit with additional refrigerant 3. measuring the weight of the cylinder 4. judgment based on pressure (test operation) 32 C Indoor temperature VRV III-C With VRV III-C however, these 4 steps are omitted since VRV III-C unit can be charged with the necessary amount of refrigerant automatically via a push button on the PCB. Automatic charging will cease once the appropriate amount of refrigerant has been transferred. If temperature drops below 10 C manual charging is necessary. After having switched to heating and once the indoor temperature rises above 10 C, push the auto charge button to activate auto charge function. Refrigerant containment is only available after performing the automatic charge function. 10 C 0 C Automatic charge function Manual charge 43 C Outdoor temperature 2. Automatic Test When refrigerant charging has ceased, pushing the test operation button on the PCB will initiate a check on the wiring, shut off valves, sensors and refrigerant volume. This test ceases automatically when completed. 3. Easy Maintenance 14 Automatic refrigerant containment check Simply activated by pressing a button on the PCB, the system calculates if any refrigerant has been lost, ensuring optimum performance of the VRV system. Self Diagnostic Function This function operated via push button on the PCB, speeds up troubleshooting and should be used for start-up and maintenance. Disconnected thermistors, faulty solenoid valves or motor operated valves, compressor malfunctions, counication errors, etc can be diagnosed quickly. Automatic Information Storage During unit operation, storage of data from the last 5 minutes occurs automatically. In cases of malfunction, analysis of data from the last 5 minutes will be carried out to identify the location of the problem and cause of malfunction. Measures to eliminate the cause of malfunction then be implemented.

15 4. Short Installation Time Thanks to small refrigerant pipes and REFNET piping options, the VRV piping system can be installed very easily and quickly. Installation of the VRV III-C system can also be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling the air conditioning system to be coissioned and operated in stages, rather than on final completion of the project. 5. Modular & Lightweight Modular design enables units to be joined together in rows with an outstanding degree of uniformity. The design of the outdoor units is sufficiently compact to allow them to be taken up to the top of a building in a coercial elevator, overcoming site transportation problem, particularly when outdoor units need to be installed on each floor. 6. No structural reinforcement necessary Thanks to the lightweight and vibration-free construction of the outdoor units, floors do not need to be reinforced, reducing the overall cost of the building. 7. Refrigerant Piping Reduced piping diameters Use of high efficiency R-410A enables the VRV III-C to operate on a smaller refrigerant charge to be used, leading to a reduction in liquid and gas pipe diameters. Reduced piping costs thanks to modular design Smaller diameter liquid and gas piping contributes to a reduction in installation space and installation costs. 4-way Piping Connection VRV III-C series not only offer the possibility to run piping from the front, but also from the left, right or bottom, thus providing greater freedom of layout. Front Left Bottom Right 15

16 features installation & maintenance friendly design 8. Unified REFNET piping The unified Daikin REFNET piping system is especially designed for simple installation. The use of REFNET piping in combination with electronic expansion valves, results in a dramatic reduction in imbalance in refrigerant flowing between indoor units, despite the small diameter of the piping. REFNET joints and headers (both accessories) can cut down on installation work and increase system reliability. REFNET joint REFNET header Attached insulators for REFNET joint Attached insulators for REFNET header Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed to optimise refrigerant flow. REFNET joint T-joint 9. Cross Wiring Check The cross wiring check facility available on the VRV is the first of its type in the industry to warn operatives of connection errors in inter unit wiring and piping. This function identifies and alerts system errors by means of on/off LEDs on the outdoor unit s PC boards. 10. Simplified Wiring A simple 2-wire non-shielded multiplex transmission system links each outdoor unit to multiple indoor units using one 2-core wire, thus simplifying the wiring operation. Furthermore, outdoor units have power connection outlets on side and front, resulting in easier installation and maintenance and saving space when rows of units are connected together. 16

17 11. Super Wiring System A Super Wiring system is used to enable the shared use of wiring between indoor units, outdoor units and the centralised remote control. This system makes it easy for the user to retrofit the existing system with a centralised remote control, simply by connecting it to the outdoor units. Thanks to a non polarity wiring system, incorrect connections become impossible and installation time is reduced way Wiring Connection Wiring can be fed from the front panel, both left and right side panels and bottom panel of the outdoor unit. 13. Auto Address Setting Function Left Front Right Allows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without the bothersome task of manually setting each address. Bottom 17

18 18

19 Outdoor Units 1. VRV III-C TECHNOLOGY 1. two stage compression Heating capacity Two stage compression technology enables the system to create higher pressures resulting in a higher heating capacity under low ambient conditions. The second inverter compressor (located in the function unit) is specially designed to provide higher pressures. Gas-liquid separator Liquid injection High After heat is exchanged in the indoor unit, gas and liquid are separated at the gasliquid separator. This enables the refrigerant in gas condition to be recovered and transmitted direct to the high pressure compressor. Pressure Gas injection Middle Low Evaporator capacity Input power Enthalpy 19

20 outdoor units VRVIII-C TECHNOLOGY VRV III Technology 1 Reluctance Brushless DC Compressor The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using 2 different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. The motor comprises powerful neodymium magnets, that create the reluctance torque. These magnets are approximately 12 times stronger than ferrite magnets and make a major contribution to its energy saving characteristics. Ferrite magnet High thrust mechanism (VRV III cooling only/heat pump) By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound level. Neodymium magnet 2 Sine Wave DC Inverter Optimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency. 20

21 3 DC Fan Motor DC fan motor structure The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation. Efficiency (%) DC motor efficiency (comparison with a conventional AC motor) AC motor Motor speed (rpm) 4 Dual DC Fans maximum 10% increase in airflow (16 HP) due to dual DC fans 10 HP: 3 blades, ø700 --> 4 blades, ø680 blade area increased by 25%, uneven pitch: No NZ noise 18 HP: ø700 --> ø540 x 2 blade area increased by 20%, sound reduced by 0.7 db > > Fans optimized for their casings (increased air flow without sound increase) increased output and reduced pressure loss together with increased external static pressure and reduced rated fan input. Internal resistance (H 2 185m /min 10HP VRV II VRV III Substantial reduction in pressure loss Three-dimensional integrated woven soft steel grilles with plastic coating High strength (withstands weight of 60 kg) Increased outflow area opening ratio Increased heat exchange area Increase in heat exchange effectiveness 5 e-pass Heat Exchanger Current Model HD Type Optimization of the path layout of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section - a more efficient use of the heat exchanger. IN 85 C 27 C 27 C 27 C OUT 45 C IN 85 C 55 C 27 C 55 C 37 C 55 C 27 C 50 C 27 C OUT 45 C 43 C 60 C 55 C OUT 45 C In cooling mode, the heat exchanger of the condensor is improved. This means an improvement of COP by 3%. 21

22 outdoor units 2. specifications Independent Unit Outdoor Unit Outdoor Unit Function unit Capacity Cooling Heating Heating Casing Colour Dimensions Unit Height Width Depth Function unit Height Width Depth Weight Unit kg Function unit kg Heat Exchanger Tube type Fan Type Piston displacement m Air Flow Rate Cooling m 3 /min (nominal at 230V) Heating m 3 /min Motor Drive Output motor W Compressor Motor Type Sound level Cooling Starting method Sound Pressure (Maximum) dba Sound Pressure (Nominal) dba Starting Method Refrigerant Name Charge kg Control Piping connections Liquid (OD) Type Diameter (OD) Gas Type Diameter (OD) Oil equalizing Type Diameter (OD) Defrost Method Capacity Control Safety devices Power Supply Name, Phase, Frequency, Voltage RTSYQ10PY1 RTSYQ14PY1 RTSYQ16PY1 RTSYQ20PY1 RTSQ10PY1 RTSQ14PY1 RTSQ16PY1 RTSQ8PY1 RTSQ12PY1 BTSQ20PY1 BTSQ20PY1 BTSQ20PY1 BTSQ20PY (1) 40.0 (4) 45.0 (7) 56.0 (10) 31.5 (2) 45.0 (5) 50.0 (8) 63.0 (11) 28.0 (3) 40.0 (6) 45.0 (9) 56.0 (12) Ivory white (5Y7,5/1) Ivory white (5Y7,5/1) Ivory white (5Y7,5/1) Ivory white (5Y7,5/1) 1,680 1,680 1,680 1, ,24 1, ,570 1,570 1,570 1, Cross fin coil Cross fin coil Cross fin coil Cross fin coil Propeller Propeller Propeller Propeller ( ) ( )+16.9 ( ) ( ) ( ) ( ) Direct drive Direct drive Direct drive Direct drive 0.75x1 0.35x2 0.75x2 (0.75)+ (0.75) Hermetically sealed scroll compressor Soft start Soft start R-410A R-410A R-410A R-410A Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type) Expansion valve (electronic type) Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Braze connection Deicer Deicer Deicer Deicer 9 to to to to 100 HPS - Fan motor driver overload protector - Over current relay - Inverter overload protector Y1, 3~, 50, (1) indoor temperature: 27 CDB, 19 CWB; outdoor temperature 35 CDB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (2) indoor temperature: 20 CDB; outdoor temperature 7 CDB,6 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (3) indoor temperature: 20 CDB; outdoor temperature -10 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 5 units (4) indoor temperature: 27 CDB, 19 CWB; outdoor temperature 35 CDB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 7 units (5) indoor temperature: 20 CDB; outdoor temperature 7 CDB,6 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 7 units (6) indoor temperature: 20 CDB; outdoor temperature -10 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 7 units (7) indoor temperature: 27 CDB, 19 CWB; outdoor temperature 35 CDB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 8 units (8) indoor temperature: 20 CDB; outdoor temperature 7 CDB,6 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 8 units (9) indoor temperature: 20 CDB; outdoor temperature -10 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 8 units (10) indoor temperature: 27 CDB, 19 CWB; outdoor temperature 35 CDB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 10 units (11) indoor temperature: 20 CDB; outdoor temperature 7 CDB,6 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 10 units (12) indoor temperature: 20 CDB; outdoor temperature -10 CWB; equivalent piping length: 7.5m; level difference 0m; function unit length: 6m; combined indoor unit: FXFQ50P x 10 units 22

23 3. ACCESSORIES Optional accessories Distributive piping Refnet header Refnet joint Kit (inlet + outlet) Air outlet Snowbreak hood* Left side air inlet Right side air inlet Back side air inlet Outdoor unit multi connection piping kit RTSYQ10PY1 RTSQ14PY1 RTSYQ20PY1 RTSYQ16PY1 KHRP26M22H (max.4 branch) KHRP26M22H (max.4 branch) KHRP26M33H (max.8 branch) KHRP26M33H (max.8 branch) - KHRP26M72H (max.8 branch) KHRP26A22T KHRP26A22T KHRP26A22T KHRP26A33T KHRP26A33T KHRP26A33T - KHRP26A72T KHRP26A72T - - KHRP26A73T KPS26C280 KPS26C504 KPS26C280* KPS26C280T KPS26C504T KPS26C280T* KPS26C504L KPS26C504L KPS26C504L* KPS26C504R KPS26C504R KPS26C504R* KPS26C280B KPS26C504B KPS26C280B* - - BHFP30A36 Note: * Snowbreak hoods are field supply. For technical drawings and more information contact your local Daikin dealer. Snowbreak hoods are advised to be installed when regular snowfall occurs. 23

24 Indoor Units 1. Features FXFQ-P Round Flow ceiling mounted cassette Comfort Modern style decoration panel in white (RAL9010) 360 air discharge ensures uniform air flow and temperature distribution Air discharge from the corners avoids dead zones that may be subject to temperature differences Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible Fresh air intake: up to 20% Flexible installation and easy maintenance Reduced installation height: 214 for class Easy visible drain check thanks to clear drain socket Drain-up pump with 850 lift fitted as standard 850 Examples of Airflow Patterns 360 Round Flow 4-Way Flow 3-Way Flow 2-Way Flow FXZQ-M Way blow ceiling mounted cassette (600x600) Comfort Modern style decoration panel in white (RAL9010) Extremely quiet in operation Excellent low draught characteristics. Since the flaps can move to a 0 position, virtually no draught can be experienced Any one of 5 different air flow patterns can be freely selected between 0 and 60 and will then be maintained during the operational cycle of the air conditioner Ceiling void is Flexible Installation and Easy Maintenance Thanks to the compact casing, it matches standard architectural modules of 600x600, therefore ceiling tile cutting is no longer necessary Air can be discharged in any of 4 directions Possibility to shut 1 or 2 flaps for easy installation in corners Since the switch box is located within the unit, it is easy to access from below for maintenance without removing ceiling tiles Drain-up pump with 500 lift fitted as standard 500

25 FXKQ-MA Ceiling mounted corner cassette Comfort Equipped with special draught prevention and anti-ceiling soiling technology 1 Standard 2 Draught prevention 3 Anti-ceiling soiling technology Note: Standard setting when shipped. Automatic air flow director ensures uniform air flow and temperature distribution Air flow by either downward air discharge, frontal discharge or a combination of both Downward discharge Frontal discharge Combination Closed by the decoration panel Flexible Installation Compact dimensions, can easily be mounted in a narrow ceiling void (only 220 ceiling space required, 195 with spacer, available as accessory) Min. 195 Panel spacer Drain-up pump with 500 lift fitted as standard FXCQ-M Way blow ceiling mounted cassette Comfort Quiet in operation Leaves maximum floor and wall space for furniture, decorations and fittings Automatic air flow director ensures uniform air flow and temperature distribution Anti-ceiling soiling technology Filter Standard long life filter Flexible Installation and Easy Maintenance Easy installation in false ceilings of only 355 Drain-up pump with 600 lift fitted as standard Maintenance can be performed by simply removing the front panel Easy to clean flat suction grille Detachable swing flaps minimum ceiling height is

26 Indoor units features FXDQ-M Small concealed ceiling unit Comfort Designed for hotel bedrooms Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Extremely quiet in operation Filter Air suction filter fitted as standard Flexible Installation Compact dimensions (230 high & 652 deep), can easily be mounted in a ceiling void The air suction direction can be altered from rear to bottom suction For easy mounting, the drain pan can be located to the left or the right of the unit FXDQ-P/NA Slim concealed ceiling unit Comfort Quiet in operation Blends unobtrusively with any interior décor Leaves maximum floor and wall space for furniture, decorations and fittings Flexible Installation Slim design, can easily be mounted in a ceiling void of only Air filter [Duct connection] Suction Chamber Can be installed in both new and existing buildings Medium external static pressure facilitates unit use with flexible ducts of varying lengths Drain-up pump with 750 lift fitted as standard Ceiling 26

27 FXSQ-M Concealed ceiling unit Comfort High flexibility for a wide variety of applications Quiet in operation Blends unobtrusively with any interior décor Filter Long life filter fitted as standard High efficiency filters (65% and 95%) available as accessory Flexible Installation and Easy Maintenance High external static pressure facilitates unit use with flexible ducts of varying lengths When using suction panel, unit requires only 350 of ceiling space Drain-up pump with 625 lift fitted as standard The air suction direction can be altered from rear to bottom suction The switch box can be reached from the side or from the bottom side of the unit for easy servicing Min NEW FXMQ-P/MA Concealed ceiling unit Comfort Leaves maximum floor and wall space for furniture, decorations and fittings Flexible Installation Compact unit (a height of 300 ), allows installation in narrow ceiling voids More than 200 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Built-in drain pump (standard for sizes 40 to 125) increases reliability of the drain system Complete range of models (FXMQ-PVE: ) (FXMQ-MAVE: ) Possibility to change ESP through wired remote control allows optimisation of the supply air volume Reduction of power consumption of 20 % (compared to FXMQ-MAVE series) through use of new DC Fan 27

28 Indoor units features FXAQ-MA Wall mounted unit Comfort Compact and stylish design blends unobtrusively in any interior décor Automatic air flow director ensures efficient air distribution via louvers that close automatically when the unit is switched off 5 different discharge angles can be prograed via the remote control Discharge angle automatically returns to its previous position on restart (initial setting 10 degrees for cooling and 70 degrees for heating) 10 Cooling 70 Heating Filter Mildew proof polystyrene filter and drain pan Flexible Installation and Easy Maintance Both horizontal flaps and front panel can easily be removed and washed All maintenance operations can be carried out from the front of the unit Drain-up pump with 1,000 lift available as accessory Drain pipe can be fitted either to the left or right side of the unit Height of drain-up 1,000 Drain-up kit Indoor unit Drain-up kit FXHQ-MA Slim concealed ceiling unit Comfort Quiet in operation Leaves maximum floor and wall space for furniture, decorations and fittings Enhanced horizontal and vertical air circulation in all directions thanks to an air flow pattern of 100 Filter Long life filter fitted as standard 100 Flexible Installation and Easy Maintance Can be installed in both new and existing buildings The ideal solution for installation without false ceilings Drain-up pump with 600 lift available as accessory Maintenance can be performed easily from below the unit Bristle free flap makes cleaning easier Drain-up kit (built inside main unit) 28

29 FXUQ-MA way blow ceiling suspended unit Comfort Group control with other VRV indoor units possible Cool heat selection Prevention of cold draught at hot start, defrost and oil return in heating Air can be discharged in any of 4 directions Air can be discharged at 5 different angles between 0 and 60 degrees Automatic air flow director ensures efficient air and temperature distribution. Air flow distribution for ceiling heights up to 3.5m without loss of capacity. Filter Air filter, drain pan and heat exchanger fin are mildew proof and antibacterial treated Flexible Installation Ideal for installation in new and existing buildings 5m maximum distance between FXUQ unit and junction box Possibility to shut 1 or 2 flaps for easy installation in corners Drain-up pump with 500 lift fitted as standard 29

30 Indoor units features FXLQ-MA Floor standing unit Comfort Ideal for installation beneath a window Compact dimensions (only 222 deep and 600 high) All models are available with remote control Filter Long life filter fitted as standard Flexible Installation and Easy Maintance Running the pipes from connections at the back, enables the unit to be wall mounted Wall mounted Floor standing On site connection during installation is easier The fibreless discharge grille prevents condensation and staining FXNQ-MA Concealed floor standing unit Comfort Ideal for perimeter air conditioning Ideal for installation below a window All models are available with remote control Filter Long life filter fitted as standard Flexible Installation and Easy Maintance On site connection during installation is easier The connecting port faces downward, eliminating the need to attach auxiliary piping Connecting port Refrigerant piping 30

31 2. specifications & accessories FXFQ-P Roundflow ceiling mounted cassette specifications FXFQ-P Capacity cooling heating Power input cooling heating Dimensions (H x W x D) Weight unit kg Casing Air Flow Rate cooling high / low m 3 /min heating high / low m 3 /min Sound power (nominal) cooling db(a) Sound pressure cooling high / low db(a) heating high / low db(a) Refrigerant name Power Supply Piping Connections L / G / D diameter Air Filter Drain-up Height model Decoration Panel colour (H x W x D) weight kg FXFQ20P FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P x 840 x x 840 x x 840 x Galvanised steel 12.5 / / / / / / / / / / / / / / / / / / / / / / / / / / / / 34 R-410A 1~ / V / 50Hz 6.35 / 12.7 / / 12.7 / / 15.9 / 32 Resin net with mold resistance 750 BYCQ140CW1 RAL x950x Notes: The sound pressure values are mentioned for a unit installed with rear suction The sound power level is an absolute value indicating the power wich a sound source generates. Nominal cooling capacities are based on: indoor temperature: 270CDB, 190CWB, outdoor temperature: 350CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent refrigerant piping: 5m, level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Accessories FXFQ-P Wired remote control Infrared remote control cooling only heat pump Decoration panel Replacement long life filter (non-woven type) Fresh air intake kit (20 % fresh air intake) (chamber type) Air discharge outlet sealing member FXFQ20P FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P BRC1D52 BRC7F533F BRC7F532F BYCQ140CW1 KAFP551K160 KDDQ5C140 KDBHQ55C140 31

32 Outdoor units spcifications & accessories FXZQ-M8 4-way blow ceiling mounted cassette (600 x 600) specifications FXZQ-M8 Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) (220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Drain-up height Power supply V1 Decoration panel dimensions (H x W x D) weight kg colour FXZQ20M8 FXZQ25M8 FXZQ32M8 FXZQ40M8 FXZQ50M x 575 x galvanised steel plate 9.0 / / / / / / / / / / R-410A ø6.4 / ø12.7 resin net with mold resistant 500 1~, 50Hz, V 55 x 700 x white (RAL 9010) Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent piping length: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent piping length: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Accessories FXZQ-M8 Wired remote control Infrared remote control Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long life filter Fresh air intake kit cooling only heat pump direct installation type FXZQ20M8 FXZQ25M8 FXZQ32M8 FXZQ40M8 FXZQ50M8 BRC1D52 BRC7E531 BRC7E530 BYFQ60B KDBH44B60 KDBQ44B60 KAFQ441B60 KDDQ44X60 32

33 FXCQ-M8 2-way blow ceiling mounted cassette specifications FXCQ-M8 FXCQ20M8 FXCQ25M8 FXCQ32M8 FXCQ40M8 FXCQ50M8 FXCQ63M8 FXCQ80M8 FXCQ125M8 Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Drain-up height Power supply V3 Decoration panel dimensions (H x W x D) weight kg colour x 780 x x 995 x x 1,180 x x 1,670 x galvanised steel plate 7 / 5 9 / / / 9 12 / / / / / / / / / / / / R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 resin net with mold resistant 600 1~, 50Hz, 230V 53 x 1,030 x x 1,245 x x 1,430 x x 1,920 x ivory white Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference: 0m. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Accessories FXCQ-M8 Wired remote control Infrared remote control Decoration panel High efficiency filter 65% *1 High efficiency filter 90% *1 Filter chamber for bottom suction Replacement long life filter cooling only heat pump FXCQ20M8 FXCQ25M8 FXCQ32M8 FXCQ40M8 FXCQ50M8 FXCQ63M8 FXCQ80M8 FXCQ125M8 BRC1D52 BRC7C67 BRC7C62 BYBC32G BYBC50G BYBC63G BYBC125G KAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160 KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160 KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160 KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160 Note: *1. Filter chamber is required when installing a high efficiency filter. 33

34 Outdoor units spcifications & accessories FXKQ-MA Ceiling mounted corner cassette specifications FXKQ-MA FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) (220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Drain-up height Power supply VE Decoration panel dimensions (H x W x D) weight kg colour x 1,110 x x 1,310 x galvanised steel plate 11 / 9 11 / 9 13 / / / / / / 37 * * * * R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 resin net with mold resistant 500 1~, 50Hz, V 70 x 1,240 x x 1,440 x ivory white Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication. Accessories FXKQ-MA FXKQ25MA FXKQ32MA FXKQ40MA FXKQ63MA Wired remote control Infrared remote control Decoration panel Panel spacer Replacement long life filter Air discharge grille Air discharge blind panel Flexible duct (with shutter) cooling only heat pump BYK45F KPBJ52F56 KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52F56 BRC1D52 BRC4C63 BRC4C61 BYK71F KPBJ52F80 KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52F80 34

35 FXDQ-M8 Small concealed ceiling unit specifications FXDQ-M8 Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (HxWxD) Weight kg Casing Air flow rate (H/L) m 3 /min Sound pressure level (H/L) db(a) Sound power level db(a) Refrigerant type Piping connections liquid/gas Air filter Power supply V3 FXDQ20M8 FXDQ25M x502x galvanised steel plate 6.7/ /5.8 37/32 50 R-410A ø6.4/ø12.7 resin net with mold resistant 1~, 50Hz, 230V Notes : Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference : 0m Nominal heating capacities are based on: indoor air temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference : 0m Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Accessories FXDQ-M8 Wired remote control Infrared remote control cooling heating FXDQ20M8 BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 FXDQ25M8 35

36 Outdoor units spcifications & accessories FXDQ-P / NA Slim concealed ceiling unit specifications FXDQ-P / NA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) db(a) Sound power level db(a) Refrigerant type Drain-up height Piping connections liquid / gas Air filter Power supply VE FXDQ20P FXDQ25P FXDQ32P FXDQ40NA FXDQ50NA FXDQ63NA x 700 x x 900 x x 1,100 x galvanised steel plate 8.0 / / / / / / / / / / / / 32 * * * * * * R-410A 750 ø6.4 / ø12.7 ø9.5 / ø15.9 removable, washable, mildew proof 1~, 50Hz, V Notes: Nominal cooling capacities are based on: Indoor temperature: 27 CDB, 19 CWB Outdoor temperature: 35 CDB Equivalent piping length: 7.5m (horizontal). Nominal heating capacities are based on: Indoor temperature: 20 CDB Outdoor temperature: 7 CDB, 6 CWB Equivalent piping length: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction. * Data were not available at time of publication. Accessories FXDQ-P / NA Wired remote control Infrared remote control cooling only heat pump FXDQ20P FXDQ25P FXDQ32P FXDQ40NA FXDQ50NA FXDQ63NA BRC1D52 BRC4C64 BRC4C62 36

37 FXSQ-M8 Concealed ceiling unit specifications FXSQ-M8 Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Drain-up height Power supply V3 Decoration panel dimensions (H x W x D) weight kg colour FXSQ20M8 FXSQ25M8 FXSQ32M8 FXSQ40M8 FXSQ50M8 FXSQ63M8 FXSQ80M8 FXSQ100M8 FXSQ125M x 550 x x 700 x x 1,000 x x 1,400 x galvanised steel plate 9 / / / / 9 15 / / / / / / / / / / / / / / R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 resin net with mold resistant 625 1~, 50Hz, 230V 55 x 650 x x 800 x x 1,100 x x 1,500 x ivory white Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference: Om. Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference: Om. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction. Accessories FXSQ-M8 Wired remote control Infrared remote control Decoration panel Service access panel High efficiency filter 65% *1 High efficiency filter 90% *1 Filter chamber for bottom suction Filter chamber rear suction Air suction canvas Screening door / blind board Air discharge adapter for round duct cooling only heat pump FXSQ20M8 FXSQ25M8 FXSQ32M8 FXSQ40M8 FXSQ50M8 FXSQ63M8 FXSQ80M8 FXSQ100M8FXSQ125M8 BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 BYBS32D BYBS45D BYB571D BYBS125D KTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160W KAFJ252L36 KAFJ252L56 KAFJ252L80 KAFJ252L160 KAFJ253L36 KAFJ253L56 KAFJ253L80 KAFJ253L160 KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160D KAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160B KSA-25K36 KSA-25K56 KSA-25K80 KSA-25K160 KBBJ25K36 KBBJ25K56 KBBJ25K80 KBBJ25K160 KDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140 Notes: *1. If installing a high efficiency filter in the unit, an assembly chamber for either bottom or rear suction is required. 37

38 Outdoor units spcifications & accessories FXMQ-P/MA NEW Concealed ceiling unit specifications FXMQ-P/MA FXMQ40P FXMQ50P FXMQ63P FXMQ80P FXMQ100P FXMQ125P FXMQ200MA FXMQ250MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Casing Air flow rate (HH/ H / L) m 3 /min Sound pressure level db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Power supply VE ,4 28, ,0 31, (1) / 0.193(2) 0.215(1) / 0.214(2) 0.230(1) / 0.229(2) 0.298(1) / 0.297(2) 0.376(1) / 0.375(2) 0.461(1) / 0.460(2) x 700 x x 1,000 x x 1,400 x x1.380x galvanised steel plate 16/13/11 18/16.5/ /17.5/16 25/22.5/20 32/27/23 39/33/28 58/50 72/62 * * * * * * 48/45 48/45 * * * * * * * * R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 ø9,5/ø19,1 ø9,5/ø22,2 cf. note 4 1~, 50Hz, V / 1~, 60Hz, 220V Notes: Nominal cooling (static pressure). Nominal heating (static pressure). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The air filter is not standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more. (1) 50Hz, V (2) 60Hz, 220V (3) Data were not available at time of publication. (4) The air filter is not standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more. *Data were not available at time of publication. Accessories FXMQ-P/MA Wired remote control Infrared remote control High efficiency filter 65% High efficiency filter 90% Filter chamber Longlife replacement filter cooling only heat pump FXMQ40P FXMQ50P FXMQ63P FXMQ80P FXMQ100P FXMQ125P FXMQ200MA FXMQ250MA BRC1D52 BRC4C66 BRC4C65 KDU-30L250 KAF372AA56 KAF372AA80 KAF372AA160 KAFJ372L280 KAF373AA56 KAF373AA80 KAF373AA160 KAFJ373L280 KDDF3AA56 KDDF37AA80 KDDF37AA160 KDJ3705L280 KAF371AA56 KAF371AA80 KAF371AA160 KAFJ371L280 38

39 FXAQ-MA Wall mounted unit specifications FXAQ-MA Cooling capacity capacity Nominal input cooling W heating W Dimensions (HxWxD) Weight kg Colour Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) (220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Power supply VE FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA x 795 x x 1,050 x white 7.5 / / 5 9 / / 9 15 / / / / / / / / 39 * * * * * * R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 resin net washable 1~, 50Hz, V Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication. Accessories FXAQ-MA Wired remote control Infrared remote control Drain pump kit cooling only heat pump FXAQ20MA FXAQ25MA FXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MA BRC1D52 BRC7E619 BRC7E618 K-KDU572DVE 39

40 Outdoor units spcifications & accessories FXHQ-MA Ceiling suspended unit specifications FXHQ-MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (HxWxD) Weight kg Colour Air flow rate (H/ L) m 3 /min Sound pressure level (H/ L) (220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid / gas Air filter Power supply VE FXHQ32MA FXHQ63MA FXHQ100MA x 960 x x 1,160 x x 1,400 x Ivory white 12 / / / / / / 37 * * * R-410A ø6.4 / ø12.7 ø9.5 / ø15.9 Resin net with mold resistant 1~, 50Hz, V Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication. Accessories FXHQ-MA Wired remote control Infrared remote control Drain pump kit Replacement long life filter L-type piping kit cooling only heat pump resin net for upward direction FXHQ32MA FXHQ63MA FXHQ100MA BRC1D52 BRC7E66 BRC7E63 KDU50M60 KDU50M125 KDU50M125 KAFJ501DA56 KAFJ501DA80 KAFJ501DA112 KHFP5M35 KHFP5M63 KHFP5M63 40

41 FXUQ-MA 4-way blow ceiling suspended unit specifications FXUQ-MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (HxWxD) Weight kg Colour Air flow rate (H/ L) Sound pressure level (H/ L) (220V) db(a) Sound power level (H) db(a) Refrigerant type Piping connections liquid / gas Air filter Power supply V1 Combination with junction box FXUQ71MA FXUQ100MA FXUQ125MA x 895 x x 895 x x 895 x white 19 / / / / / / R-410A ø9.5 / ø15.9 ø9.5 / ø15.9 ø9.5 / ø15.9 resin net with mold resistant 1~, 50Hz, 230V BEVQ71MA BEVQ100MA BEVQ125MA Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB, 24 CWB. Nominal heating capacities are based on: indoor temperature: 20 CDB, 15 CWB outdoor temperature: 7 CDB, 6 CWB. Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat. Accessories FXUQ-MA FXUQ71MA FXUQ100MA FXUQ125MA Wired remote control Infrared remote control cooling only heat pump BRC1D52 BRC7C529 BRC7C528 Sealing member of air discharge outlet Air discharge decoration panel Vertical flap kit Replacement long life filter L-type connection piping kit KDBHJ49F80 KDBTJ49F80 KDGJ49F80 KHFP49M63 KAFJ495F140 KDBHJ49F140 KDBTJ49F140 KDGJ49F140 KHFP49M140 JUNCTION BOX FOR CONNECTION TO VRV BEVQ-MA Dimensions H x W x D Weight kg Casing Power supply VE BEVQ71MA BEVQ100MA BEVQ125MA 100x350x225 x galvanised steel plate 1~, 50Hz, V BEVQ-MA 41

42 Outdoor units spcifications & accessories FXLQ-MA Floor standing unit specifications FXLQ-MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (H x W x D) Weight kg Colour Air flow rate (H/L) m 3 /min Sound pressure level (H/L) (220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid/gas Air filter Power supply VE FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA x 1,000 x x 1,140 x x 1,420 x ivory white 7/6 7/6 8/6 11/8.5 14/11 16/12 35/32 35/32 35/32 38/33 39/34 40/35 * * * * * * R-410A ø6.4/ø12.7 ø9.5/ø15.9 resin net with mold resistant 1~, 50Hz, V Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 7.5m (horizontal). Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 7.5m (horizontal). Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. *Data were not available at time of publication. Accessories FXLQ-MA Wired remote control Infrared remote control Long life replacement filter cooling only heat pump FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 KAFJ361K28 KAFJ361K45 KAFJ361K71 42

43 FXNQ-MA Concealed floor standing unit specifications FXNQ-MA Cooling capacity Heating capacity Nominal input cooling W heating W Dimensions (HxWxD) Weight kg Casing Air flow rate (H/L) m 3 /min Sound pressure level (H/L)(220V) db(a) Sound power level db(a) Refrigerant type Piping connections liquid/gas Air filter Power supply VE FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA x 1,00 x x 1,140 x x 1,420 x Ivory white 7/6 7/6 8/6 11/8.5 14/11 16/12 35/32 35/32 35/32 38/33 39/34 40/35 * * * * * * R-410A ø6.4/ø12.7 ø9.5/ø15.9 Resin net with mold resistant 1~, 50Hz, V Notes: Nominal cooling capacities are based on: indoor temperature: 27 CDB, 19 CWB outdoor temperature: 35 CDB equivalent refrigerant piping: 8m level difference: Om. Nominal heating capacities are based on: indoor temperature: 20 CDB outdoor temperature: 7 CDB, 6 CWB equivalent refrigerant piping: 8m level difference: Om. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. The sound pressure values are mentioned for a unit installed with rear suction. Accessories FXNQ-MA Wired remote control Infrared remote control Replacement long life filter cooling only heat pump FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA BRC1D52, BRC2C51, BRC3A61 BRC4C64 BRC4C62 KAFJ361K28 KAFJ361K45 KAFJ361K71 43

44 Ventilation 1. HRV-Heat Reclaim Ventilation 1. VAM-FA8 The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly. HRV units can be controlled individually or integral with the air conditioning system Daikin VRV or Sky Air series) Total heat exchanged foul air Clean outdoor air Foul indoor air Total heat exchanged clean air 9 models to choose from Compact, energy saving ventilation Specially developed heat exchange element with HEP (High Efficiency Paper) Easy integration into the VRV system Connectable to current Daikin control systems: VAM-FA 44 VENTILATION Air flow rate m/h 3 Sound pressure level (max.) (1) dba External static pressure (max.) Pa Temperature exchange efficiency % Enthalpy exchange efficiency heating % cooling % Dimensions H W D Weight kg Duct diameter Power supply VE (1) Sound pressure level is measured in heat exchange mode. VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA ,000 1,500 2,000 27/ /29 32/34 33/ / /37 36/ / / ,498 1, , , Ø 100 Ø 150 Ø 150 Ø 200 Ø 200 Ø 250 Ø 250 Ø 350 Ø 350 1~, 50Hz, V

45 2. VKM-GA / VKM-GAM Heat purge (economiser): heat accumulated indoors is discharged at night Integration of humidification and air conditioning into HRV unit Increased static pressure thanks to improved fan performance Individual control via HRV remote control Connectable to current Daikin control systems: VKM-GAM VENTILATION, DX coil & humidifier Fresh air conditioning load cooling heating Air flow rate ultra high - high - low m/h 3 Sound pressure level - 220V ultra high - high - low dba Sound pressure level - 240V ultra high - high - low dba Static pressure ultra high - high - low Pa Temperature exchange efficiency ultra high - high - low % Enthalpy exchange efficiency - cooling ultra high - high - low % Enthalpy exchange efficiency - heating ultra high - high - low % Humidifier type Humidification capacity kg/h Dimensions height width depth Weight kg Power supply V1 VKM50GAM VKM80GAM VKM100GAM natural evaporating humdifier ,764 1,764 1, ,214 1, ~, V, 50Hz VKM-GA VENTILATION & DX coil Fresh air conditioning load cooling heating Air flow rate ultra high - high - low m/h 3 Sound pressure level - 220V ultra high - high - low dba Sound pressure level - 240V ultra high - high - low dba Static pressure ultra high - high - low Pa Temperature exchange efficiency ultra high - high - low % Enthalpy exchange efficiency - cooling ultra high - high - low % Enthalpy exchange efficiency - heating ultra high - high - low % Dimensions height width depth Weight kg Power supply V1 VKM50GA VKM80GA VKM100GA ,764 1,764 1, ,214 1, ~, V, 50Hz 45

46 ventilation 2. FXMQ-MFV1 - Outdoor Air Processing Unit Combined fresh air treatment and air conditioning via a single system. Both fresh air treatment and air conditioning can be achieved successfully in a single system via heat pump technology without the usual design problems associated with balancing air supply and discharge. Air conditioning fan coil units and an outdoor air treatment unit can be connected to the same refrigerant line, resulting in enhanced design flexibility and a significant reduction in total system costs. 100% fresh air intake possible Leaves maximum floor and wall space for furniture, decorations and fittings Operation range: -5 C to 43 C 225 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas Drain pump kit available as accessory FXMQ-MFV1 indoor Units FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 Capacity cooling kw heating kw Power Input cooling kw heating kw Dimensions HxWxD 470x744x1, x1380x1,100 Weight kg Air Flow Rate cooling medium m 3 /min heating medium m 3 /min Refrigerant - Power Supply V/50Hz Piping Connections liquid (od)/gas/drain 9.5 / 15.9 / PS1B 9.5 / 19.1 / PS1B 9.5 / 22.2 / PS1B 46

47 3. VRV +EXV-kit - VRV Air Handling Applications A new range of R-410A inverter condensing units for multi application with air handling units. Inverter controlled units Large capacity range (from 5 to 18HP) Cooling only R-410A Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed) Large range of expansion valve kits available BRC1D52 is used to set the set point temperature (connected to the EKEXMCB). EXV-kit Air handling unit gas pipe liquid pipe F1, F2 counication EKEXMCB Cooling only RXQ-P(A) Capacity range HP Capacity cooling kw Power input (Nominal) cooling kw Dimensions HxWxD 1,680x635x765 1,680x930x765 1,680x1,240x765 Weight kg Sound Level sound power cooling dba sound pressure cooling dba Air Flow Rate (nominal at 230V) cooling m³/min Operation Range cooling min~max CDB -5.0~43.0 Refrigerant R-410A Power Supply 3N~/400V/50Hz Max n of indoor units to be connected Piping connections liquid (OD)/gas 9.5 / / / / / / 28.6 Combination table Outdoor unit 3ph Control box Expansion valve kit control z class 50 class 63 class 80 class 100 class 125 class 140 class 200 class 250 EKEXMCB EKEXV50 EKEXV63 EKEXV80 EKEXv100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 RXQ5P x x x x x x x x x RXQ8P x x x x x x x x x RXQ10P x x x x x x x x x RXQ12P x x x x x x x x x RXQ14PA x x x x x x x x x RXQ16PA x x x x x x x x x RXQ18PA x x x x x x x x x 47

48 Powerful Selection Prograes 1. VRV Xpress Daikin has developed a new user friendly, software tool that allows rapid VRV selection and provides a professional result in the 7 following steps: 1. Select indoor units 2. Connect outdoor units to indoor units 3. Automatic receipt of piping diagram with joints 4. Automatic receipt of wiring diagram 5. Connect appropriate centralised control systems 6. Visualise result in Microsoft Word, Microsoft Excel and AutoCAD 7. Save project Using VRV Xpress enables VRV selection to be achieved in a simple, complete and professional manner. Windows95, Windows98, WindowsNT, Windows2000, WindowsXP and WindowsVista are registered trademarks of Microsoft corporation. 48

49 2. VRV pro Features: The VRV Pro selection prograe offers 3 separate modes to accoodate different design formats according to customer requirements. Multi languages are possible. 1. Expert mode: once the cooling and heating loads in the different rooms have been calculated, the software will select the most appropriate system plus an estimate of the power consumption. 2. Quick mode: based on calculated system loads, the software will select the most appropriate system. 3. Drawing mode: selecting the indoor and outdoor units from a list enables the user to design a system in no time at all. A simple to use, Daikin computerised selection prograe, designed for use with Windows 95, Windows 98, WindowsNT, Windows 2000, Windows XP and WindowsVista systems, enables consulting engineers, design and build contractors, property developers and architects etc. to plan a Daikin air conditioning project on a step by step basis, complete with detailed drawings, bills of quantities and costs. The prograe thus enables VRV air conditioning systems to be engineered precisely and economically (without over-sizing units), thereby ensuring optimum operating cycles and maximum energy efficiency. Windows95, Windows98, WindowsNT, Windows2000, WindowsXP and WindowsVista are registered trademarks of Microsoft corporation. 49

50 User Friendly Control Systems 1. Individual control systems BRC4* BRC7* Infrared remote control Operation buttons: ON / OFF, timer mode start / stop, timer mode on / off, prograe time, temperature setting, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), operating mode, fan speed control, filter sign reset, inspection / test indication Display: Operating mode, battery change, set temperature, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), prograed time, inspection / test operation, fan speed BRC2C51 Simplified remote control Simple, compact and easy to operate unit, suitable for use in hotel bedrooms Operation buttons: ON / OFF, operating mode selection, fan speed control, temperature setting Display: Cool / heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost / hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test / operation BRC3A61 Simplified built-in remote control for hotel applications Compact, user friendly unit, ideal for use in hotel bedrooms Operation buttons: ON / OFF, fan speed control, temperature setting 50 Display: Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost / hot start, malfunction

51 Wired remote control BRC1D52 Limit operation (min/max): room temperature is controlled within adjustable upper and lower limits. Limit operation can be activated manually or by schedule timer Real time clock: indicates real time and day Schedule timer: - It is possible to prograe a weekly schedule timer - It is possible to prograe the remote control for each day of the week. Five day actions can be set as follows: Set point: unit is switched ON and normal operation is maintained OFF: unit is switched OFF Limits: unit is switched ON and min / max control (cf. limit operation for more details) Home leave (frost protection): during occupants absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF Different levels of disabled buttons can be selected as follows: - Level 1: all buttons are accessible - Level 2: all buttons are disabled except for: ON / OFF, set temperature up / down, fan speed, cooling / heating mode, enable / disable schedule timer, air flow direction adjustment button - Level 3: all buttons are disabled except for: ON / OFF, set temperature up / down, fan speed User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed Constantly monitoring of the system for malfunctions in a total of 80 components Iediate display of fault location and condition Reduction of maintenance time and costs Operation buttons: ON / OFF, timer mode start / stop, timer on / off, prograed time, temperature setting, air flow direction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test / operation Display: Operating mode, Heat Recovery Ventilation (HRV) in operation, cool / heat changeover control, centralised control indication, group control indication, set temperature, air flow direction, prograed time, inspection / test operation, fan speed, clean air filter, defrost / hot start, malfunction 51

52 user friendly control systems 2. Centralised control systems DCS302C51 Centralised remote control Providing individual control of 64 groups (zones) of indoor units A maximum of 64 groups (128 indoor units, max. 10 outdoor units) can be controlled A maximum of 128 groups (128 indoor units, max. 10 outdoor units) can be controlled via 2 centralised remote controls in separate locations Zone control Group control (up and down buttons are added for group selection) Control of HRV air flow direction and air flow rate Expanded timer function Malfunction code display Maximum wiring length of 1,000m (total: 2,000m) DCS301B51 Unified ON/OFF control Providing simultaneous and individual control of 16 groups of indoor units A maximum of 16 groups (128 indoor units) can be controlled 2 remote controls in separate locations can be used Operating status indication (normal operation, alarm) Centralised control indication Maximum wiring length of 1,000m (total: 2,000m) DST301B51 Schedule timer Enabling 64 groups to be prograed A maximum of 128 indoor units can be controlled 8 types of weekly schedule A maximum of 48 hours back-up power supply Maximum wiring length of 1,000m (total: 2,000m) 52

53 3. Network Solutions DS-NET adapter P1 - P2 F1 - F2 The ideal solution for control and management up to 2,000 indoor units PC for monitoring Modem Public phone line RS485 Malfunction Modem RS232C Max. of 10 DS-NET adapters P1 - P2 F1 - F2 Application area A small coercial area of less than 40 indoor units. Critical applications for centralized monitoring. System layout Allows monitoring and control of up to up to 50 stores or sites and 2,000 indoor units with just one modem and phone line. Automates daily air conditioning operation in order to free users from the hassle of air conditioning operation / management. The daily schedule setting allows automatic operation afterward. Automates alarm (report messages) for any malfunctions / errors. Iediate report of any indoor unit breakdown to the servicing company. Automatic report of breakdown / malfunction information. Minimizes the inconvenience of not having air conditioning via rapid messages Functions Schedule setup (Daily schedule) - Start / stop A / C malfunction report - Send message to monitoring system Manual operation - Start / Stop, set temperature, operation mode, fan speed Status monitoring - Start / Stop, set temperature, - Operation mode, room temperature, operation time, error code 53

54 user friendly control systems Allows detailed and easy monitoring and operation of VRV systems (max. 2 x 64 control groups) Languages English, French, German, Italian, Spanish System layout Up to 2 x 64 indoor units can be controlled Onboard Ethernet port (web browser & ) Digital i / o contacts (option) Touch panel (full colour LCD via icon display) Management Web application & internet compatibility - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet Power Proportional Distribution (option) PPD data is available on the internet Easy management of electricity consumption Enhanced history function Control Individual control (set point, start / stop, fan speed) (max. 2 x 64 indoor units / groups) Schedule control (8 schedules, 17 patterns) Flexible grouping in zones Yearly schedule Fire emergency stop control Interlocking control Increased HRV monitoring and control function Automatic cooling / heating changeover Quick selection and full control Simple navigation Heating optimization Temperature limit Password security: 3 levels (general, administration & service) Air Conditioning Network Service System Public line PCMCIA flash memory CSV output of PPD (option) result Onboard Ethernet port Onboard modem Remote monitoring / control via internet, PPD data is available on internet third party controller (domotics, BMS, etc.) Ethernet Pi-port Links to the wattmeter when using the PPD (option) function Malfunction 54

55 Forced OFF contact input Fire alarm Monitoring Visualisation via Graphical User Interface (GUI) Icon colour display change function Indoor units operation mode Error messages via & mobile phone (option) Indication filter replacement Multi PC DIII-NET Indoor units DIO unit HRV Cost performance Labour saving Easy installation Compact design: limited installation space Overall energy saving Controls drain pump, lighting etc. Monitoring of room enter/exit sign Open interface Counication to any third party controller (domotics, BMS, etc.) is possible via open interface. RS-232C DIII-NET PLUS adapter DI unit DIII-NET Allows monitoring/control of up to 64 units (groups) Indoor unit HRV Connectable to VRV HRV Sky Air (via interface adapter) Split (via interface adapter) 55

56 user friendly control systems The ideal solution for control and management of maximum 1,024 VRV indoor units System layout Up to 1,024 indoor units can be controlled (by 4 ipus) Ethernet TCPIP / 10 base / T counication Integrated digital contacts on the Intelligent Processing Unit (ipu) - 19 general input ports - 2 digital outputs Stand alone operation of the ipu for minimum 48 hours Compatible with UPS shutdown software Management Web access function (option) Power Proportional Distribution Operational history management (start/stop, malfunction, operation hours) Generation of reports (graphics & tables) (daily, weekly, monthly) Peak load shedding Advanced tenant management Sliding temperature Eco mode (option) Control Individual control (setpoint, start / stop, fan speed) (max. 1,024 indoor units) Group control (100 groups) Schedule control (128 programs) Fire emergency stop control (32 programs) Interlocking control Setpoint limitation Automatic cooling heating changeover Power failure / release control Temperature limit (automatic start) Timer extension Monitoring Visualisation via a Graphical User Interface (GUI) featuring free layout Operation mode of indoor & outdoor units Fault indication Indication filter replacement Setpoint indication Operation time monitoring Multi PC On-line help ~ Intranet/Internet Web Access Web Access Malfunction report by (Via Internet) Air Conditioning Network Service System (Optional Maintenance Service) DAM602B51/52 Ai unit DIII-NET DIII-NET DIII-NET Dio unit Power supply facility ETHERNET DIII-NET Fire alarm Electricity Measurement 56 Sub PC ~ DMS502A51 BACnet Gateway (monitoring only) Local monitoring & control VRV System Daikin Central Air Conditioning System HRV

57 LON BMS Lonworks Networks Compatible Gateway LonTalk adapter dms504b51 DIII- NET Interface for connection to LonWorks networks Counication via Lon protocol (twisted pair wire) 64 units connectable per DMS-IF Unlimited site size Quick and easy installation ETHERNET (TCP/IP) BUILDING CONTROL NETWORK HRV adapter LonTalk LonPoint LonPoint Local Control Remote Control VRV Outdoor unit DAIKIN A / C INFRASTRUCTURE Security Fire alarm System Integrated control system connecting VRV system with BMS system. PPD data is available on BMS-system Interface for BMS system Counication via BACnet protocol (connection via Ethernet) 256 units connectable per BACnet gateway Unlimited site size Easy and fast installation BMS DMS502A51 DIII- NET DAM602B51 / 52 (Intelligent Manager) Control and monitoring Local Control VRV Outdoor unit BACNET / ETHERNET HRV DAIKIN A / C INFRASTRUCTURE Remote Control Fire alarm Security Power supply facility BUILDING CONTROL NETWORK Pump Lighting Elevator 57

58 user friendly control systems 4. accessories Individual control systems DESCRIPTION FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ Wired remote control Infrared remote control Simplified remote control Simplified remote control for hotel use cooling only heat pump BRC1D52 BRC7F533 BRC7E531 BRC7C67 BRC4C63 BRC4C64 BRC4C64 BRC4C64 BRC4C66 BRC7C529 BRC7E66 BRC7E619 BRC4C64 BRC4C64 BRC7F532 BRC7E530 BRC7C62 BRC4C61 BRC4C62 BRC4C62 BRC4C62 BRC4C65 BRC7C528 BRC7E63 BRC7E618 BRC4C62 BRC4C BRC2C51 BRC2C51 BRC2C51 BRC2C BRC2C51 BRC2C BRC3A61 BRC3A61 BRC3A61 BRC3A BRC3A61 BRC3A61 Centralised control systems DESCRIPTION Centralised remote control Unified ON/OFF control Schedule timer FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ DCS302C51 DCS301B51 DST301B51 Others DESCRIPTION Wiring adapter Wiring adapter (hour meter) Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) Remote sensor Installation box for adapter PCB Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface only) External control adapter Interface adapter for Sky Air series Connector for forced on/forced off FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ - KRP1B57*1 - KRP1B61 KRP1B61 KRP1B56 - KRP1B61 KRP4A53 KRP1B3 - KRP1B61 KRP1B61 EKRP1C11*1 - EKRP1B2 - EKRP1B2*2 - EKRP1B KRP2A526*1 KRP2A526*1 KRP2A516*1 KRP2A61 KRP2A516 KRP2A53 KRP2A516 KRP2A61 KRP2A62* KRP2A51 KRP2A51 KRP2A51 KRP4AA53*1 KRP4A536*1 KRP4A516*1 KRP4A51 KRP4A516 KRP4A54 KRP4A516 KRP4A51 KRP4A52* KRP4A51 KRP4A51 KRP4A51 KRCS01-4 KRCS01-1 KRP1H98 KRP1BA101 KRP1B96*3/4 - - KRP1BA101 - KRP1B97 KRP1C93*3 KRP4A93*3/ KJB311A KJB212AA KJB212A - KEK26-1A - DTA104A52 DTA104A51*1 DTA104A61 DTA104A51 DTA104A53 DTA104A51 DTA104A61 DTA104A62 DTA104A51 DTA104A61 DTA104A DTA102A EKRORO Notes: *1: Installation box is required *2: Fixing box is KRP1A90 *3: Up to 2 adapters can be fixed per installation box *4: Only 1 installation box can be installed per indoor unit DESCRIPTION DS-net adapter Software REFERENCE DTA113B51 DPC001B1-B51 COMMENTS 4 units can be connected per adapter, 40 units when 10 adapters are connected Monitoring panel software DESCRIPTION REFERENCE COMMENTS Intelligent Touch Controller Software Hardware Installation box Touch-Pen Interface adapters Digital input Digital input/output DCS601C51 2x64 units can be connected DCS002C51 Power Proportional Distribution (PPD) software DCS004A51 / Web software DCS601A52 DIII NET-Plus adapter KJB411A For wall mounted installation Spare part n of Touch-Pen for Intelligent Touch Controller KRP928A2S For connection to Split units DTA102A52 For connection to R-22 / R-407C Sky Air units DTA112B51 For connection to R-410A Sky Air units DEC101A51 Input contacts: 16 points DEC102A51 Input contacts: 8 points; output contacts: 4 points 58

59 DESCRIPTION REFERENCE COMMENTS Intelligent Processing unit Software Interface adapters DIII Ai Digital input Digital input / output Power Proportional Distribution ECO Mode Web Acces Function DAM602B51 DAM602B52 IM3.XX KRP928A2S DTA102A52 dta112b51 DAM101A51 DEC10151* DEC10251* DAM002A51 DAM003A51 DAM004A indoor units per IPU 128 indoor units per IPU Up to 1,024 indoor units For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units Outdoor temperature sensor Input contacts: 16 points Input contacts: 8 points; output contacts: 4 points DESCRIPTION REFERENCE COMMENTS LonWorks networks compatible Gateway Interface adapters DMS504B51 KRP928A2S DTA102A52 dta112b51 Up to 64 units can be connected per DMS-IF For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units DESCRIPTION REFERENCE COMMENTS BACnet Gateway DIII board Digital input/output Interface adapters DMS502B51 DAM411B51 DAM412B51 KRP928A2S DTA102A52 dta112b51 64 units per Gateway Extension of 3 x DIII lines (3 x 64) indoor units For forced shutdown For connection to Split units For connection to R-407C/R-22 Sky Air units For connection to R-410A Sky Air units BMS: Building Management system DESCRIPTION REFERENCE COMMENTS Contact / analog signal Parallel interface - Basic unit Temperature measurement units Temperature setting units Unification adapter for computerised control Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (2) External control adapter for outdoor unit DIII-net expander adapter Mounting kit DPF201A51 DPF201A52 DPF201A53 DCS302A52 KRP2A51 KRP2A52 KRP4A51-53 DTA104A51 DTA104A52 DTA109A51 KRP4A92 enables ON/OFF coand, operation and display of malfunction can be used in combination with up to 4 units. enables temperature measurement output for 4 groups; 0~5VDC.» enables temperature setting input for 16 groups; 0~5VDC.» used for combining of air conditioning control computer and central remote controller (ON/OFF, display) simultaneously controls air conditioning control computer and up to 64 groups of indoor units. to control the group of indoor units collectively, which are connected by the transmission wiring of remote controller. cooling/heating mode change over, demand control and low noise control are available between the plural outdoor units. a maximum of 10 outdoors or 128 indoors can be connected to 1 DTA109A51 a maximum of 8 DTA109A51 can be connected to DIII-net for easy installation of the DTA109A51 59

60 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium BTW: BE RPR Oostende Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. VRV products are not within the scope of the Eurovent certification prograe. FSC The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Daikin products are distributed by: EPCEN XXXX 05/08 Copyright Daikin The present publication supersedes EPCEN Printed on non-chlorinated paper. Prepared by La Movida, Belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

. Creating Maximum Comfort

. Creating Maximum Comfort P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system

More information

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S SYSTEMS t a b l e o f C O N T E N T S INTRODUCTION Who is Daikin? p 4 The history of VRV systems p 5 WHAT IS? p 6 PRODUCT EXPLANATION p 10 Possible indoor units using R-407C p 12 Possible outdoor units

More information

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM. SHOPS MULTI SYSTEM RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM 2009 www.daikin.co.uk ABOUT DAIKIN Daikin UK is a leading supplier of heating, cooling and refrigeration solutions for commercial, residential

More information

Daikin Airconditioning UK Ltd

Daikin Airconditioning UK Ltd Daikin Airconditioning UK Ltd Daikin Europe N.V. p. 02 Daikin has a worldwide reputation based on over 70 years experience in the successful manufacture of high quality air conditioning equipment for industrial,

More information

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz Service Manual RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz R-410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi 1.2 PREFACE...x Part 1 General Information... 1 1. Model Names of Indoor/Outdoor

More information

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV1217 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV0915 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz PCVAU0828B WATER COOLED INVERTER SERIES HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz A water cooled intelligent individual suitable for tall multi-storeyed build This unique system can perform as heat pump or heat

More information

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of The ideal air conditioning system for small offices and shops Extending the core 5S concept Space saving, Sufficient capacity, Slim design, Soundreduced operation and Single phase power supply Daikin s

More information

EPCE03-06D. The Next Generation of Air Conditioning Systems

EPCE03-06D. The Next Generation of Air Conditioning Systems EPCE03-06D The Next Generation of Air Conditioning Systems T a b l e o f TC O N T E N T S INTRODUCTION Who is Daikin? p 4 The history of VRV systems p 6 WHAT IS? p 8 THE INTELLIGENT AIR CONDITIONING SYSTEM

More information

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz SiE39-40 Service Manual RXYQ5-48MAY1 R410A Heat Pump 50Hz SiE39-40 R410A Heat Pump 50Hz 1 Introduction vi 11 Safety Cautions vi 12 PREFACE x Part 1 General Information 1 1 Model Names of Indoor/Outdoor

More information

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV0915 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz 201812 Engineering Data Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V Heat Pump 60 Hz Heat Recovery 60 Hz RWEQ-TATJU (208 / 230 V, 60 Hz) RWEQ-TAYDU (460 V, 60 Hz) RWEQ-TAYCU

More information

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz SiBE3-402A Service Manual R-410A Heat Pump 50Hz SiBE3-402A R410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi Part 1 General Information... 1 1. Model Names of Indoor/Outdoor Units...2

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................

More information

VRVIV-0117-E. Cooling Only 50 Hz

VRVIV-0117-E. Cooling Only 50 Hz VRVIV-0117-E Some model names might differ and some products might not be available depending on the country of sale. For further information, please contact one of our sales companies. Cooling Only 50

More information

PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to

PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to Warning PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to product conforms to the applicable standards, and is suitable for use, in the region where

More information

Concealed ceiling units

Concealed ceiling units Concealed ceiling units Daikin concealed ceiling units an invisible improvement to any space Why choose Daikin? Daikin is a world leader in air conditioning and heating. So no matter what your needs, you

More information

VRV HEAT RECOVERY

VRV HEAT RECOVERY PART 1: GENERAL 1.01 SYSTEM DESCRIPTION A. The variable capacity, heat pump heat recovery air conditioning system shall be a Daikin VRF (Variable Refrigerant Flow) AURORA system for cold climate installation,

More information

COOLING ONLY HEAT PUMP

COOLING ONLY HEAT PUMP Warning PCVID06F Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION What is Daikin VRV IV S-series? One flexible package Daikin VRV IV S-series

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

For small and medium-sized food retailers. Conveni-Pack. The integrated solution for refrigeration, heating and air conditioning

For small and medium-sized food retailers. Conveni-Pack. The integrated solution for refrigeration, heating and air conditioning For small and medium-sized food retailers Conveni-Pack The integrated solution for refrigeration, heating and air conditioning Daikin is a strong competitor in the refrigeration market. We aim to deliver

More information

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz PCVMT1603aprv Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

Product. ortfolio. Integrated climate control

Product. ortfolio. Integrated climate control Product ortfolio Integrated climate control Portfolio Outdoor unit range Capacity (HP) System Product name 4 5 6 8 0 4 6 8 0 RYYQ-T Heat pump with continuous heating () () () RXYQ-T Heat pump without continuous

More information

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135 124 OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135 Water-Cooled VRV RWEYQ-MY1 136 INDOOR UNITS 1. Cassette

More information

Daikin air conditioners for shops, restaurant and offices

Daikin air conditioners for shops, restaurant and offices Daikin air conditioners for shops, restaurant and offices ROUNDFLOW CEILING MOUNTED CASSETTE w w w. d a i k i n. e u FCQH-C The new Daikin Sky Air Roundflow Cassette: Daikin has renewed its Sky Air ceiling

More information

Product. ortfolio. Integrated climate control

Product. ortfolio. Integrated climate control Product ortfolio Integrated climate control Portfolio Outdoor unit range Capacity (HP) System Product name 4 5 6 8 0 4 6 8 0 Cooling capacity (kw).6 4.0 5.5.4 8.0.5 40.0 45.0 49.0 55.9 Heating capacity

More information

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz 201806 Engineering Data RXYQ-TAYCU, 575 V Heat Pump 60 Hz RXYQ-TAYCU (575 V, 60 Hz) 1. Features and Benefits...3 2. Nomenclature...4 3. Model Names of Indoor Unit and Outdoor Unit...7 3.1 Outdoor Units...7

More information

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147 140 OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147 Water-Cooled VRV RWEYQ-MY1 148 INDOOR UNITS 1. Cassette

More information

NFZP Variable Refrigerant Flow Guide Specification

NFZP Variable Refrigerant Flow Guide Specification PART 1 - GENERAL 1.01 SECTION INCLUDES SECTION 23 81 29 VARIABLE REFRIGERANT FLOW HVAC SYSTEM A. (VRF) HVAC system includes: 1. Outdoor/Condensing unit(s): a. Size Range: 14 Tons Nominal b. YANMAR VRF

More information

VRV IV S-series heat pump

VRV IV S-series heat pump VRV IV S-series heat pump The most compact VRV Most compact unit on the market 3mm high & kg Control systems Indoor units VRV type indoor units Residential type indoor units (such as Daikin Emura) Air

More information

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING DAIKIN VRV LIFE Re-inventing residential air-conditioning by breaking technological barriers, Daikin VRV LIFE systems

More information

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU SiUS39-601 RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU R-410A Heat Pump 60Hz 1. Introduction... vi 1.1 Safety Cautions...vi 1.2 PREFACE...

More information

Concealed ceiling unit with medium ESP

Concealed ceiling unit with medium ESP FXSQ-A Concealed ceiling unit with medium ESP Slimmest yet most powerful medium static pressure unit on the market Slimmest unit in class, only 245mm (3mm built-in height) and therefore narrow ceiling

More information

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings PCV3 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,

More information

Daikin air conditioners for your home, shops, restaurants and offices

Daikin air conditioners for your home, shops, restaurants and offices Daikin air conditioners for your home, shops, restaurants and offices CONCEALED CE ILING UN IT www.daikineurope.com FDEQ-B7 Concealed ceiling units are built into the false ceiling, leaving only the suction

More information

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC January 2018 Engineering Data RXSQ24-60TAVJU Heat Pump 208/230V / 60 Hz / 1 ph Presales Manual DAIKIN NORTH AMERICA LLC DAIKIN NORTH AMERICA LLC RXSQ_TAVJU VRV LIFE TM Heat Pump Unit Contents 1. Features

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air conditioners, heating & cooling. for large spaces. air to air heat pumps.   FDQ-B Air conditioners, heating & cooling for large spaces CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDQ-B THE MOST ADVANCED CLIMATE CONTROL FOR LARGE SPACES The quality air conditoning of Daikin

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTED UN IT www.daikineurope.com FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series stylish

More information

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air technical data FHYKP-B Ceiling Mounted Corner Cassette air conditioning systems Split Sky Air Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human

More information

The Multi-talented VRV-S.

The Multi-talented VRV-S. Revolutionary comfort. Anywhere and everywhere. The Multi-talented VRV-S. R-410A INVERTER Light commercial :: Residential :: Renovation :: New Construction The singular pursuit of Absolute Comfort. Daikin

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling 4 - W a y B l o w C e i l i n g M o u n t e d C a s s e t t e Energy label:» Up to class A Heat pump system Inverter technology Fits precisely» in standard modules» of

More information

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

AIR CONDITIONERS, HEATING & COOLING for your home

AIR CONDITIONERS, HEATING & COOLING for your home AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides

More information

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type PVVAU1722 Preview 50 Hz Ceiling Mounted Cassette ( Round Flow with Sensing ) Type FXFSQ-AVM Round flow Circulation Airflow Evenly Distributes Cool Air Circulation Airflow P.5 Indoor unit lineup Ceiling

More information

LV Series. SEER 15+ Concealed Built in Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump LV Series SEER 15+ Concealed Built in Heat Pump EXPERTISE AND INNOVATION Daikin s slim duct systems offer a built in solution with the benefits of duct free technology. Installed similar to a traditional

More information

for small rooms in multi application

for small rooms in multi application Air conditioners, heating & cooling for small rooms in multi application concealed ceiling unit air to air heat pumps www.daikin.eu FDbq-b HOSPITALITY STARTS WITH A STABLE AND DRAUGHT-FREE INDOOR CLIMATE

More information

w w w. d a i k i n. e u ATXS-E

w w w. d a i k i n. e u ATXS-E Daikin air conditioners for your home WALL MOUNTED UNIT ATXS-E w w w. d a i k i n. e u Daikin s stylishly elegant wall mounted Siesta unit will grace the dining, living or bedroom of any home. Siesta will

More information

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Remote control infrared ARC433B76 ARC433A8 ARC433B69 Cooling Only INDOOR UNITS FDKS25E FDKS35E FDKS50C FDKS60C Capacity cooling min~nom~max kw 1.3~2.4~3.0 1.4~3.4~3.8 1.7~5.0~5.3 1.7~6.0~6.5 Power input cooling min~nom~max kw -~0.69~- - ~1.09~- -~1.65~-

More information

Ultimate VRF System R410A, 50Hz

Ultimate VRF System R410A, 50Hz Ultimate VRF System R410A, 50Hz TVR WIZ Systems, a new leap in technology and innovation A proven solution from a trusted advisor Trane is proud to present their new line of variable refrigerant systems,

More information

DC Inverter Smart VRF Products(R410A)

DC Inverter Smart VRF Products(R410A) DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is

More information

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity

More information

Heat Reclaim Ventilation. VRV Air Handling Applications. a wide variety of daikin solutions. ventilation systems

Heat Reclaim Ventilation. VRV Air Handling Applications. a wide variety of daikin solutions.   ventilation systems Heat Reclaim Ventilation ventilation systems Outdoor Air Processing Unit VRV Air Handling Applications www.daikin.eu a wide variety of daikin solutions for the provision of fresh air and ventilation Daikin

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

Water cooled VRV IV W-series

Water cooled VRV IV W-series Water cooled VRV IV W-series Ideal for high rise buildings, using water as heat source Unified range for heat pump & heat recovery and standard & geothermal series 22 Indoor units VRV type indoor units

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e Energy label:» Up to class A Heat pump system Seasonal inverter technology Round flow 360 air discharge Fits flush» into a false ceiling

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for small rooms in multi application Daikin air conditioners for sall roos in ulti application CONCEALED CE ILING UN IT www.daikineurope.co FDBQ-B Concealed ceiling units are ideal for use in sall roos such as hotel bedroos. They are built

More information

DC inverter VRF presentation

DC inverter VRF presentation DC inverter VRF presentation NINGBO DEKON REFRIGERATION EQUIPMENT CO., LTD Wangchun Industrial Park, Yinzhou district,ningbo, China. Tel: 0086-574-88152763 Mob: 0086-15356475680 www.dekon-hvac.com Email:

More information

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating

More information

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Keep looking you ll never find me. VRV IV heat pumps for indoor installation Keep looking you ll never find me i VRV IV heat pumps for indoor installation Invisible Keep looking you ll never find me Daikin VRV IV i-series offers you the most aesthetic and integrated air conditioning

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

Ventilation. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Ventilation. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Ventilation All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration Daikin Europe N.V. ABOUT DAIKIN Daikin has a worldwide reputation based on almost 85 years experience

More information

VRV IV i-series heat pump

VRV IV i-series heat pump VRV IV i-series heat pump for indoor installation unique patented concept Air curtain Biddle Air curtain for VRV (CYV) 22 Indoor units VRV type indoor units Control systems Ventilation Heat Reclaim ventilation

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WALL MOUNTE D UNIT w w w. d a i k i n. e u FTKS/FTXS-D Daikin has taken a further step towards achieving the ideal combination of style and efficiency. The D series

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

your comfort. our world. Ventilation Catalogue Heating Ventilation Integrated Solutions Air Conditioning Refrigeration

your comfort. our world. Ventilation Catalogue Heating Ventilation Integrated Solutions Air Conditioning Refrigeration your comfort. our world. Ventilation Catalogue Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Daikin Europe N.V. ABOUT DaiKIN Daikin has a worldwide reputation based on almost

More information

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading

More information

Air conditioners, heating & cooling for the retailmarket and offices

Air conditioners, heating & cooling for the retailmarket and offices Air conditioners, heating & cooling for the retailmarket and offices floor standing unit air to air heat pumps www.daikin.eu FVQ-B MAXIMUM RELIABILITY, MINIMUM ENERGY USE Advanced climate systems in modern

More information

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

air conditioners for your home, shops, restaurants, offices, small hotels   MULTI MODEL APPLICATIONS air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture

More information

for your home FLXS-B Flexi type unit air to air heat pumps

for your home FLXS-B Flexi type unit   air to air heat pumps Air conditioners, HEATING & COOLING for your home Flexi type unit air to air heat pumps www.daikin.eu FLXS-B TOP CLASS, MADE FOR A LONG FUTURE The importance of well-being and pleasure is increasing in

More information

VRV, integrated climate control. for medium to large commercial spaces

VRV, integrated climate control. for medium to large commercial spaces VRV, integrated climate control for medium to large commercial spaces Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated

More information

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment

More information

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to

More information

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for small rooms in multi application Daikin air conditioners for sall roos in ulti application CONCEALED CE ILING UN IT www.daikineurope.co FDBQ-B7 Concealed ceiling units are ideal for use in sall roos such as hotel bedroos. They are built

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

SHOPS, RESTA URA NTS, OFFICES, HOTELS,

SHOPS, RESTA URA NTS, OFFICES, HOTELS, AIR CONDITIONERS FOR YOUR HOME, A P A RTMENTS, SHOPS, RESTA URA NTS, OFFICES, HOTELS, Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air

More information

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and

More information

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air technical data FDKS-CVMB Concealed ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDKS-CVMB TABLE OF CONTENTS FDKS-CVMB 1 Features.............................................................

More information

VRV, INTEGRATED CLIMATE CONTROL FOR MEDIUM TO LARGE COMMERCIAL SPACES

VRV, INTEGRATED CLIMATE CONTROL FOR MEDIUM TO LARGE COMMERCIAL SPACES VRV, INTEGRATED CLIMATE CONTROL FOR MEDIUM TO LARGE COMMERCIAL SPACES Total Solution Concept The Daikin VRV Total Solution provides a single point of contact for the design and maintenance of your integrated

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

Daikin leads the way:

Daikin leads the way: Daikin leads the way: Offering a full range of light commercial products optimised for seasonal efficiency All Seasons Climate comfort Heating Air Conditioning Applied Systems Refrigeration Daikin leads

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling R o u n d F l o w C a s s e t t e F U L L R A N G E A C L A S S E N E R G Y L A B E L Seasonal efficiency, optimized for all seasons Heat pump system Round flow principle:

More information

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR FTQ SERIES DUCTED HEAT PUMP SYSTEMS LEADING TECHNICAL PERFORMANCE

More information

FAQ. Wall Mount Heat Pump or Cooling Only

FAQ. Wall Mount Heat Pump or Cooling Only FAQ Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FAQ wall mount SkyAir systems feature streamlined indoor units in both cooling only and heat pump models. Sleek and sophisticated

More information

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S air conditioners for your home, apartments, shops, restaurants, offices, hotels, S U P E R M U L T I P L U S ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful

More information

AIR CONDITIONERS LINE-UP

AIR CONDITIONERS LINE-UP For Qatar IR CONDITIONERS LINEUP PRODUCT CTLOGUE 2017 SPLIT / WINDOW 50 HZ BOUT US Top Leader Brand in Middle East Fujitsu General started the sales of Window type air er in 1960 and expands the overseas

More information

Daikin air conditioners for your home

Daikin air conditioners for your home Daikin air conditioners for your home WLL MOUNTED UNIT www.daikineurope.com FTXG-C The UX1 has already won the Good Design ward 2003 for its modern design. This stylish wall mounted unit is available in

More information

Air Conditioners. Technical Data FBQ-C

Air Conditioners. Technical Data FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Air Conditioners Technical Data C o n c e a l e d C e i l i n g U n i t E E D E N 1 0-1 0 0 FBQ-C Indoor

More information

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air technical data FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit air conditioning systems Split Sky Air Indoor Units R410A FDXS-CVMB TABLE OF CONTENTS FDXS-CVMB 1 Features.............................................................

More information

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology. Our mission Achieve the lowest environmental impact

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology. Our mission Achieve the lowest environmental impact Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology Our mission Achieve the lowest environmental impact The most comfortable cassette just got better New round flow cassette

More information