COOLING ONLY HEAT PUMP

Size: px
Start display at page:

Download "COOLING ONLY HEAT PUMP"

Transcription

1 Warning PCVID06F Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. JMI-007 Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION Organization: DAIKIN INDUSTRIES (THAILAND) LTD. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM JQA-45 Dealer Dealer All of the Daikin Group s business facilities and subsidiaries in Japan international standard for environment management. A special air condi tioning system designed for sma ll s an d shops Head Office: Umeda Center Bldg., -4-, Nakazaki-Nishi, PT. DAIKIN AIRCONDITIONING INDONESIA Head Office: Kita-ku, Osaka, Japan GRHA37, 3rd FloorTokyo Office: JR Shinagawa East 0730, Bldg., -8-, Konan, Jl. Pangeran Jayakarta No. 37, Jakarta Indonesia Phone : Minato-ku, Tokyo, Japan Fax : Website : c All rights reserved 08/ Y.K. Specifications, designs and other content appearing in this brochure are current as of August 0 but subject to change without notice. COOLING ONLY HEAT PUMP Only 50 Hz/60 Hz Heat Pump 50 Hz/60 Hz

2 The ideal air conditioning system for small offices and shops Extending the core 5S conceptspace saving, Sufficient capacity, Slim design, Soundreduced operation and Single phase power supplydaikin s VRVIII-S offers added value with the E concepteasy installation. With all these features and more, we proudly present the ideal air conditioning system designed for small-sized buildings. Slim, compact and sufficient capacity The VRVIII-S is highly space saving, featuring slim and compact outdoor units. It is suitable for small offices and shops with capacities of 4, 5 and 6 HP. Volume Approx. 50% reduction The 5S+E concepts of Footprint 635 VRVIII Approx. 40% reduction 900 (5 HP) (4, 5, 6 HP) VRVIII (5 HP) (4, 5, 6 HP) 5S concept Space saving Sufficient capacity Slim design Sound-reduced operation Single phase power supply Easy installation E E concept Contents Outdoor unit can be installed on a balcony The compact, trunk-shaped outdoor unit can easily be installed on a balcony, realising complete system installation within each floor. This enables more useful utilisation of the space on the building rooftop. Introduction... page Main features...page 3 Control systems... page 9 Indoor unit lineup... page 5 Specifications... page 5 Indoor units... page 5 Outdoor units... page 3 Option list... page 33 Indoor units... page 33 Outdoor units...page 35 Control systems...page 35

3 MAIN FEATURES Wide range of choices To suit the variety of rooms found in small offices and shops, the VRVIII-S system offers wide range of indoor and outdoor units. VRVIII-S indoor and outdoor units are almost as easy to install as residential air conditioning systems, making them ideal for small offices and shops. Indoor units 4 types 7 models* A wide range of indoor units includes 7 models in 4 types. The indoor units can be selected to match every room and preference. Outdoor units 3 models Outdoor unit can be selected from three models to provide the power that suits your needs. The trunk-shaped outdoor unit can be neatly installed outside the office. Outdoor unit lineup Model Name Capacity Range Capacity Index RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE 4 HP (. ) 5 HP (4.0 ) 6 HP (5.5 ) Indoor unit lineup Ceiling Mounted Cassette (Round Flow) Ceiling Mounted Cassette (Compact Multi Flow) Ceiling Mounted Cassette (Double Flow) Ceiling Mounted Cassette Corner Model Name FXFQ-PVE FXZQ-MVE FXCQ-MVE FXKQ-MAVE FXDQ-PBVE (with drain pump) 4 types 7 models* Capacity Range 0.8 HP HP.5 HP.6 HP HP.5 HP 3. HP 4 HP 5 HP Capacity Index HP 40 Slim Ceiling Mounted Duct Ceiling Mounted Duct FXDQ-PBVET (without drain pump) FXDQ-NBVE (with drain pump) FXDQ-NBVET (without drain pump) FXMQ-PVE (700 width type) (900/,00 width type) Ceiling Suspended FXHQ-MAVE Wall Mounted New FXAQ-PVE New New New New New New Floor Standing FXLQ-MAVE Concealed Floor Standing FXNQ-MAVE Note: R-40A VRV system indoor units are not compatible with the R- VRV system. * 3 types and 68 models for 60 Hz specifications. Connection unit series indoor units (50 Hz only) Ceiling Suspended Cassette Model Name FXUQ-MAV Capacity Range Capacity Index Connection Unit 0.8 HP HP.5 HP.6 HP HP 3 HP 4 HP 5 HP BEVQ7MAVE BEVQ00MAVE BEVQ5MAVE Note: BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details. 3 4

4 MAIN FEATURES Energy efficiency and quiet operation Outdoor units use Daikin s unique scroll compressor to realise energy saving performance and quiet operation. High COP during both cooling and heating operations One of the top features of the VRVIII-S is its energy efficiency. It achieves high COP during cooling and heating operations by employing Daikin s unique scroll compressor. Quiet operation provides luxurious comfort Quietness is yet another important feature of Daikin s VRVIII-S system. To reduce noise and realise comfortable operation, latest technologies and features are applied to the outdoor units. 4 HP 5 HP 6 HP 4 HP 5 HP 6 HP VRVII-S Previous model RXYM-MVM Above values are based on the following nominal conditions: Ceiling Mounted Cassette (Round Flow) type units are connected (4 HP: FXFQ50P x ; 5 HP: FXFQ63P x ; and 6 HP: FXFQ63P + FXFQ80P.) : Indoor temp. of 7 CDB, 9 CWB, and outdoor temp. of 35 CDB. : Indoor temp. of 0 CDB, and outdoor temp. of 7 CDB, 6 CWB. Lower operation sound is achieved in cooling operation! VRVII-S Previous model RXYM-MVM High COP achieved in all ranges! db(a) reduced in each model! 4 HP 5 -db(a) 50 5 HP 5 -db(a) 5 A collection of cutting-edge technologies realises efficient and quiet operation. The high efficiency compressor to achieve a higher COP Compressor equipped with Reluctance DC motor Daikin DC inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses different types of torque, neodymium magnet* and reluctance torque*. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. Motor efficiency (%) Reluctance DC motor More than 0% AC motor Conventional DC motor Rotational speed (rps) Small load Low capacity Large load High capacity Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products. * A neodymium magnet is approximately 0 times stronger than a standard ferrite magnet. * The torque created by the change in power between the iron and magnet parts. Reluctance DC motor >> Smooth sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. Sine wave DC inverter 3 RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE Nighttime quiet operation function Operation sound level selectable from 3 steps for the night mode Mode. Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours* after the peak temperature in the daytime, and operation will return to normal 0 hours* after that. The operation sound level for the night mode can be selected from 47 db(a) (Step ), 44 db(a) (Step ) and 4 db(a) (Step 3). Capacity % Load % Mode. Automatic mode Peak in outdoor temperature 8 hrs 0 hrs (Initial setting) (Initial setting) Smooth Air Inlet Bell Mouth and Aero Spiral Fan These two features work to reduce sound. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. With the bent blade edge Without the bent blade edge Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. 5 Mode. Manual mode Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA04A6 or DTA04A6, and a locally obtained timer are necessary.) Mode 3. Combined mode Combinations of modes and can be used depending on your needs. *. Initial setting. Can be selected from 6, 8 and 0 hours. *. Initial setting. Can be selected from 8, 9 and 0 hours. Operation sound db(a) Step max. - 3 db(a) ( 4 HP/. ) Step max. - 6 db(a) ( 4 HP/. ) Step 3 max. - 9 db(a) ( 4 HP/. ) Night mode starts Night Mode Step : 47 db(a) Step : 44 db(a) Step 3: 4 db(a) Night mode ends 8:00 :00 6:00 0:00 0:00 4:00 8:00 Note: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. The capacity reduction rate differs depending on the operation sound level step selected. 3 DC fan motor Efficiency improved in all areas compared to conventional AC motors, especially at low speeds. DC fan motor structure Efficiency (%) Approx. 40% increase DC motor efficiency (comparison with AC motor) DC motor Approx. 0% increase AC motor Motor speed (rpm) Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. 6

5 MAIN FEATURES Design flexibility VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and multiple indoor unit combinations, which provides generous freedom for office and shop design both inside and out. As many as 9 indoor units can be connected to a single outdoor unit Multiple indoor unit combinations are possible.* As many as 9 indoor units can be connected to a single outdoor unit, making the VRVIII-S a remarkably versatile system. * Total capacity index of connectable indoor units must be % of the capacity index of the outdoor unit. For a 6 HP installation Long piping design possible The VRVIII-S provides the long piping length possibility of 50 m, with a total piping length of 300 m. If the outdoor unit is installed above indoor units the level difference can be up to a maximum of 50 m. These generous allowances facilitate an extensive variety of system designs. Actual piping length Max. 50 m Total piping length Max. 300 m Max. 9 units * >> Max. 8 indoor units for a 5 HP installation >> Max. 6 indoor units for a 4 HP installation Max. 5 m Level difference between indoor units Max. 50 m* Level difference Notes: *. 40 m when the outdoor unit is installed below indoor units. *. Maximum piping length between the indoor unit and the first branch is 40 m. Easy installation A variety of functions are provided that make installation easier, such as simple wiring and piping and automatic test operation. Easy wiring A printed circuit board has been adopted that is easy to see and wire during installation. Automatic test operation Simply press the test operation button and the unit performs an automatic system check, including wiring, shutoff valves, and sensors. The results are returned automatically after the check finishes. Simple wiring and piping connection Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily. >> Super wiring system A super wiring system is used to enable shared use of the wiring between indoor and outdoor units and the central control wiring, with a relatively simple wiring operation. The DIII-NET counication system is employed to enable the use of advanced control systems. Central remote controller Outdoor unit Indoor unit Previous model VRVII-S >> REFNET piping system Wide operation temperature range The versatile operation range of the VRVIII-S system works to reduce limitations on installation locations. The operation temperature range for heating goes all the way down to -0 C, while cooling can be performed with outdoor temperatures as high as 46 C. Both these achievements are due to the adoption of a high-pressure dome-type compressor. Outdoor temperature ( CDB) Certified operation temperature range 46 CDB -5 CDB Outdoor temperature ( CWB) CWB CWB Daikin s advanced REFNET piping system makes installation easy. Only two main refrigerant lines are required in any one system. REFNET greatly reduces the imbalances in refrigerant flow between units, while using small-diameter piping. 7 8

6 CONTROL SYSTEMS Control systems The VRVIII-S system uses the same DIII-NET counication system as the VRV, enabling the use of advanced control systems. Individual control systems Navigation remote controller (Wired remote controller) (Option) Large buttons and arrow keys for easy operation. Guide on display gives an explanation of each setting. Backlight and dot matrix LCD display for easy viewing. Weekly schedule timer can be set up easily. 0 display languages are available. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian and Turkish) Wireless remote controller (Option) The same operation modes and settings as with wired remote controllers are possible. A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included. A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit. Signal receiver unit can be installed on the panel ex. Ceiling Mounted Cassette (Round Flow) type BRCE6 Signal receiver unit (Separate type) Wired remote controller (Option) Displays current airflow, swing, temperature, operating mode and timer settings. Wired remote controller with weekly schedule timer (Option) Adds weekly schedule timer function. Wireless remote controller *Wireless remote controller and signal receiver unit are sold as a set. *Refer to page 35 for the name of each model. Signal receiver unit (Installed type) Simplified remote controller (Option) BRCC6 BRCD6 Notes:. Standard remote controllers (BRCC6) not required.. If the BRCD6 is connected to the centralised remote controllers (DCS303A5, DCS30CA6, DCS30BA6, DST30BA6), the schedule function is not available. The wired remote controller supports a wide range of control functions Exposed type (BRCC5) Concealed type (For hotel use) (BRC3A6) The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms. The exposed type remote controller is fitted with a thermostat sensor. The concealed type remote controller smartly fits into a night table or console panel in a hotel room. Control of Cool/Heat changeover In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote controller of the indoor unit. Outdoor unit Equipment related to the central control Group control One remote controller can control the operation of max.6 indoor units at the same time. Control by two remote controller The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last coand has a priority.) Of course, the group control by two remote controller is also possible. Wide variation of remote controllers for indoor units Navigation remote controller (Wired remote controller) (BRCE6) Wired remote controller (BRCC6) FXFQ FXZQ FXCQ FXKQ FXDQ FXMQ FXHQ FXAQ FXL(N)Q FXUQ Remote controller Remote controller Remote controller Indoor unit Remote control The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for the different indoor units in one place. 3 Control for the combined operation Wired remote controller with weekly schedule timer (BRCD6) Wireless remote controller* (Installed type signal receiver unit) Remote controller Remote controller Remote controller Remote controller Heat Reclaim Ventilator Forced OFF input Remote controller The operation of Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter. 4 Expansion of system control Wireless remote controller* (Separate type signal receiver unit) Simplified remote controller (Exposed type) (BRCC5) 3 4 The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc. Simplified remote controller (Concealed type: for Hotel use) (BRC3A6) 9 Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. *Refer to page 35 for the name of each model. 0

7 CONTROL SYSTEMS Centralised control systems Up to 64 groups of indoor units (8 units) can be centrally controlled. Optional controllers for centralised control can be combined and optimised in accordance with building scale and purpose. System integration with various air-conditioning peripheral equipment such as Heat Reclaim Ventilator is easy. Wiring can be run up to a total length of km, and adapts easily to large-scale system expansion. DCS303A5 Residential central remote controller* (Option) Max. 6 groups of indoor units can be easily controlled with the large LCD panel. Max. 6 groups (8 indoor units) controllable Backlight and large LCD panel for easy readability ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. All indoor units can be turned on or off at once with ALL button. Each group has a dedicated button for convenience. Outside temperature display *For residential use only. Cannot be used with other centralised control equipment. Central remote controller (Option) Unified on/off controller (DCS30BA6) Connection of up to 8 units possible Connectable number of centralised control equipment Address setting of central control can be performed from the remote controller. Independent and centralised control of Heat Reclaim Ventilator is possible. DCS30CA6 Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller. Max. 64 groups (8 indoor units) controllable Max. 8 groups (8 indoor units) are controllable by using central remote controllers, which can control from different places. Zone control Malfunction code display Max. wiring length,000 m (Total:,000 m) Connectable with Unified ON/OFF controller, schedule timer and BMS system Airflow volume and direction can be controlled individually for indoor units in each group operation. Ventilation volume and mode can be controlled for Heat Reclaim Ventilator. Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer. Central remote controller units Group control of up to 6 units is possible (group control via automatic address setting) Unified on /off controller Schedule timer 8 units unit Unified ON/OFF controller (Option) Max. 6 groups of indoor units can be operated simultaneously/individually. Forced shut-down input Central remote controller (DCS30CA6) Up to units connectable Schedule timer (DST30BA6) unit connection possible; 8 weekly schedule control patterns possible System without remote control is also available. Interface adaptor for SkyAir series (built-in indoor unit) (DTA0A5) 6 cores 7 cores max. Unification adaptor for computerised control (DCS30A5) Central control adaptor kit (DTA07A55) Wiring adaptor for other airconditioners (DTA03A5) Outdoor-air processing unit can be connected. Interlink Building Management System (host computer monitor panel) also possible. Refer to page 7 for the total number of indoor units that can be connected to the outdoor unit. Certain indoor units limit the functions of some control systems. For more details, please refer to the Engineering Data Book. DCS30BA6 DST30BA6 Max. 6 groups (8 indoor units) controllable remote controllers can be used to control from different places. Operating status indication (Normal operation, Alarm) Centralised control indication Max. wiring length,000 m (Total:,000 m) Compact size casing (Thickness: 6 ) Connectable with Central Remote controller, Schedule timer and BMS system Schedule timer (Option) Max. 8 indoor units can be operated as prograed schedule. Max. 8 indoor units controllable When used in combination with a central remote controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to ON/OFF pairs can be set per day. Max. 48 hours back up power supply Max. wiring length,000 m (Total:,000 m) Compact size casing (Thickness: 6 ) Connectable with Central Remote controller, Unified ON/OFF controller and BMS system

8 CONTROL SYSTEMS Advanced control systems New One touch selection to total air comfort Daikin proudly introduces its new intelligent Touch Manager, a VRV system controller featuring an array of simple, useful system management functions for added value. Up to,560 groups (5,0 indoor units) can be controlled by one system system overview Air Conditioning Network Service System Internal modem (option) New DCM60A5 Counication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system. system overview DCS60C5 System Dio Unit DEC0A5 (Option) Input (Lights) Di Unit DEC0A5 (Option) Input (Key signal - General purpose ADP) Phone line LAN line Max. 64 groups Set temperature change coand OFF coand Internet Intranet LAN itm plus adaptor line Max. 50m itm plus adaptor (Max. 7 adaptors) Web Access USB memory Fire alarm Di/Pi line Max. 00m h meter I/O expansion line Max. 500m Di/Pi port I/O System (Max. 30 modules) I/O module I/O module I/O module Air Conditioning Network Service System modem for Via internet System Components ACC centre Air Conditioning Network Service System (Optional Maintenance Service) RS-3C D -NET Plus Adaptor DCS60A5 (Option) Indoor Unit D -NET Number of indoor units expanded from 64 to 8. Heat Reclaim Ventilator Web Access Lighting Pump Fan Sensor Features Central control Handy area settings simplify detailed management of VRV. Display of floor plans enables a quick search of desired air conditioning units. Operation history shows manner of control and origin in past operations of air conditioning units. Remote access Remote access with a PC allows total air conditioning management using the same type of screens as those displayed in the intelligent Touch Manager. Authorised users can centrally control individual air conditioning units from their own computers. Automatic control VRVs are controlled automatically throughout the year by the schedule function. Interlocking VRVs and other equipment enables easy automation of building facilities operation. Setback adjusts temperature settings even when rooms are unoccupied. Energy management The Energy Navigator feature simplifies energy management by tracking energy consumption data and identifying inefficient operation. Troubleshooting Contact information of maintenance contractors can be registered and displayed. s are sent automatically to alert of malfunctions and potential trouble. The intelligent Touch Manager can link to the Air Conditioning Network Service System for 4-hour monitoring of operating conditions and status. Scalability A single intelligent Touch Manager can manage a small building or be expanded to handle medium- to large-sized buildings. Large building properties can also take advantage of the itm integrator to link up and expand system up to 5 intelligent Touch Managers for integrated control. Features Colour LCD touch panel icon display Small manageable size Simplified engineering Multi language (English, French, Italian, German, Spanish, Dutch, Portuguese, Chinese and Korean) Yearly schedule Auto heat/cool change-over Temperature limitation Enhanced history function Simple Interlock Function Built-in modem for connecting to Air Conditioning Network Service System (Option) Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option) Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit) 3 4

9 INDOOR UNIT LINEUP Ceiling Mounted Cassette (Round Flow) FXFQ5P/ FXFQ3P/ FXFQ40P FXFQ50P/ FXFQ63P/ FXFQ80P FXFQ00P/ FXFQ5P Ceiling Mounted Cassette (Compact Multi Flow) FXZQ0M/FXZQ5M FXZQ3M/FXZQ40M FXZQ50M 360 airflow improves temperature distribution and offers a comfortable living environment. Quiet, compact, and designed for user comfort The industry s first* Round Flow Ceiling Mounted Cassette type offers 360 airflow with improved temperature distribution. 4-way flow Round Flow Dimensions correspond with 600 X 600 architectural module ceiling design specifications. Low operation sound level (db(a)) FXZQ-M 0/ There are areas of uneven temperature. *As of April 004, the release date for Japan. All models are lighter than the conventional ones. Ex: Models FXFQ5P-50P are 4.5 lighter (reduced from 4 to ). pump is equipped as standard accessory, and the 850 lift height has been improved from 750 to 850. A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating. Treated surface Resists soiling Example of airflow patterns: 360 airflow is available, as well as - to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout. Untreated surface Dirt and grime Condition after exposure to the smoke of 600 cigarettes in m 3 enclosed space. Control of the airflow rate has been improved from -step to 3-step control. Low operation sound level FXFQ-P Sound level (HH/H/L) 5/ There are much fewer areas of uneven temperature (db(a)) 5 30/8.5/7 3/9/7 3//7 34/3/8 36/33.5/3 43/37.5/3 44/39/34 All-round flow An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean. The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter. 4-way flow 3-way flow L-shaped -way flow Sound level (H/L) Comfortable airflow 0 Wide discharge angle: 0 to 60 Auto swing Fixed angles: 5 levels Angles can be also set on site to prevent drafts (0-35 ) or soiling of the ceiling (5-60 ), other than standard setting (0-60 ). 30 V 40 V -, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room. 4-way flow 30/5 3/6 36/8 4/33 3/6 34/8 37/9 4/35 3-way flow L-shaped -way flow For 3-way or -way flow installation, the sealing member for air discharge outlet (option) must be used to close each unused outlet. pump is equipped as standard accessory with 750 lift Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet. 6

10 INDOOR UNIT LINEUP Ceiling Mounted Cassette (Double Flow) FXCQ0M/ FXCQ5M/ FXCQ3M FXCQ40M/ FXCQ50M/ FXCQ63M FXCQ80M/ FXCQ5M Ceiling Mounted Cassette Corner FXKQ5MA/FXKQ3MA FXKQ40MA/FXKQ63MA Thin, lightweight, and easy to install in shallow ceiling spaces Slim design for flexible installation The low profile unit (only 305 high) can be installed in a ceiling space as shallow as 350. All models feature a compact design with a depth of only 600. FXCQ-M (When a high-efficiency filter is attached, the unit's height is 400.) Low operation sound level Sound level (H/L) 5/3 40/ (db(a)) 5 0 V 3/7 34/8 34/9 37/3 39/34 44/38 40 V 34/9 36/30 37/3 39/34 4/36 46/40 Designed with higher airflow suitable for high ceiling application up to 3 metres. Slim body needs only 0 space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 95. Min.95 0 Single-flow type allows effective air discharge from corner or from drop-ceiling. pump is equipped as standard accessory with 500 lift. 500 Panel spacer Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature. (m) 3 8 C 3 C 30 C 6 C 4 C C 0 C (m) Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall. Main body Downward discharge Providing different settings of standard and ceiling soiling prevention, the auto swing mechanism achieves even distribution of airflow and room temperature. pump is equipped as standard accessory with 600 lift. Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method). A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 5 day/month. For dust concentration of 0.5 mg/m 3 Set for front discharge using a suspended ceiling. Main body Air discharge grille (Option) Air discharge grille (Option) 600 Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy. Downward discharge is shut off and air is blown straight out (front discharge). A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 5 day/month. For dust concentration of 0.5 mg/m 3 7 8

11 INDOOR UNIT LINEUP Slim Ceiling Mounted Duct Slim design, quietness and static pressure switching Ceiling Mounted Duct FXMQ0P/FXMQ5P/FXMQ3P FXMQ40P/FXMQ50P/FXMQ63P FXMQ80P/FXMQ00P/FXMQ5P FXMQ40P Suited to use in drop-ceilings! FXDQ0PB/FXDQ5PB/FXDQ3PB Only 700 in width and 3 in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels. Great for hotel use! FXDQ40NB/FXDQ50NB/FXDQ63NB Only 00 in height, this model can be installed in rooms with as little as 40 depth between the drop-ceiling and ceiling slab. Middle and high static pressure allows for flexible duct design A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility. 30 Pa 00 Pa for FXMQ0P-3P 30 Pa 60 Pa for FXMQ40P 50 Pa 00 Pa for FXMQ50P-5P 50 Pa 40 Pa for FXMQ40P Only ,00 in width for the FXDQ63NB model. All models are only 300 in height, an improvement over the 390 height of conventional models. The weight of the FXMQ40P has been reduced from 44 to 8. Suspension bolt* Air filter 300 AIR Discharge grille* AIR Suction grille* 40 *To be obtained locally Easy installation in buildings with narrow ceiling spaces pump is equipped as standard accessory with 700 lift. Control of the airflow rate has been improved from -step to 3-step control. Low operation sound level FXDQ-PB/NB Sound level (HH/H/L) 0/5/3 33/3/ /3/ /33/3 (db(a)) 63 36/34/3 The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 db(a). Values are based on the following conditions: FXDQ-PB: external static pressure of 0 Pa; FXDQ-NB: external static pressure of 5 Pa. External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model. 0 Pa-30 Pa/factory set: 0 Pa for FXDQ-PB models. 5 Pa-44 Pa/factory set: 5 Pa for FXDQ-NB models. FXDQ-PB and FXDQ-NB models are available in two types to suit different installation conditions. FXDQ-PB/NBVE: with a drain pump (750 lift) as a standard accessory FXDQ-PB/NBVET: without a drain pump 750 Ceiling 700 Ceiling Control of the airflow rate has been improved from -step to 3-step control. Low operation sound level (db(a)) FXMQ-P 0/ / Sound level 33/3/9 34/3/30 39/37/35 4/39/37 4/40/38 43/4/39 44/4/40 46/45/43 (HH/H/L) Energy-efficient The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 0% decrease in energy consumption. (FXMQ5P) Improved ease of installation Airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately ±0% of the rated HH tap airflow for FXMQ0P-5P. Improved ease of maintenance The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. 9 0

12 INDOOR UNIT LINEUP Ceiling Suspended Wall Mounted FXHQ3MA/ FXHQ63MA FXHQ00MA New FXAQ0P/FXAQ5P FXAQ3P/FXAQ40P FXAQ50P/FXAQ63P Slim body with quiet and wide airflow Adoption of QUIET STREAM FAN Stylish flat panel design harmonised with your interior décor Stylish flat panel design creates a graceful harmony that enhances any interior space. Uses the quiet stream fan and many advanced technologies. Sound absorption material Flat panel can be cleaned with only the single pass of a cloth across their smooth surface. Flat panel can also be easily removed and washed for more thorough cleaning. Turbulent flow is produced Quiet stream fan Straightening vane Low operation sound level FXAQ-P (db(a)) 63 Low operation sound level (db(a)) Sound level (H/L) 35/3 36/3 38/3 39/34 4/37 47/4 FXHQ-MA Sound level (H/L) 3 36/ / /37 pan and air filter can be kept clean by mould-proof polystyrene. Installation is easy pump kit (option) can be easily incorporated. Vertical auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops pump kit (built inside main unit) Wide air discharge openings produce a spreading 00 airflow. Maintenance is easy Non-dew Flap with no implanted bristles Bristle-free Flap minimises contamination and makes cleaning simpler. Easy-to-clean flat design Non-dew Flap Maintenance is easier because servicing can be performed from below the unit. A long-life filter (maintenance free up to one year) is equipped as standard accessory. 5 steps of discharge angle can be set by remote controller. Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 0 for cooling and 70 for heating) Flexible installation pipe can be fitted to from either left or right sides. pump kit is available as optional accessory, which lifts the drain,000 from the bottom of the unit. Height of drain-up,000 pump kit Indoor unit

13 INDOOR UNIT LINEUP Floor Standing FXLQ0MA/ FXLQ5MA FXLQ3MA/FXLQ40MA FXLQ50MA/ FXLQ63MA Connection unit series indoor units Ceiling Suspended Cassette (50 Hz only) FXUQ7MA FXUQ00MA FXUQ5MA Suitable for perimeter zone air conditioning Floor Standing types can be hung on the wall for easier floor cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier. A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 5 day/month. For dust concentration of 0.5 mg/m 3 Concealed Floor Standing Wall hanging Floor installation This thin indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity Depending on installation site requirements or room conditions, -way, 3-way and 4-way discharge patterns are available. 4-way airflow from the centre of the store. The 3-way airflow can distribute comfortable air throughout the room. Only one unit is needed to distribute comfortable air throughout an L-shaped store. FXNQ0MA/ FXNQ5MA FXNQ3MA/ FXNQ40MA FXNQ50MA/ FXNQ63MA Designed to be concealed in the perimeter skirting-wall The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design. The connecting port faces downward, greatly facilitating on-site piping work. A long-life filter (maintenance free up to one year ) is equipped as standard accessory. 8 hr/day, 5 day/month. For dust concentration of 0.5 mg/m 3 Connecting port Refrigerant piping Applies also to Floor Standing type (FXLQ-MA). Connection unit BEVQ7MA/BEVQ00MA/BEVQ5MA Liquid pipe Refrigerant piping layout VRV -S series outdoor unit Gas pipe length* Connection unit is the device for connecting above indoor unit to VRVIII-S. Connection unit for indoor unit BEVQ-MAVE Indoor unit External wiring layout Super wiring (DIII-NET) Single-phase 0-40 V power supply Indoor unit Remote controller * Maximum piping length Model between the BEV unit and the indoor unit. FXUQ-MA 5 m Notes: When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA0A5). Connection unit BEVQ-MA is necessary for each indoor unit. The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m. The BEV unit must be installed within a maximum height difference between indoor units of 5 m. Branching of the refrigerant piping is not possible downstream of the BEV unit. 3 4

14 SPECIFICATIONS 5 INDOOR UNITS Ceiling Mounted Cassette (Round Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (HH/H/L) Sound level (HH/H/L) Gas (Flare) Panel (Option) Model Colour Weight (*) (*) (*) db(a) FXFQ5PVE FXFQ3PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ00PVE FXFQ5PVE,500 9,900,600 6,000 9,800 4,900 3, ,800 3,400 4,300 5,400 6,900 8,600 0, Galvanised steel plate 46X840X840 46X840X840 46X840X840 46X840X840 46X840X840 46X840X840 88X840X840 88X840X840 VP5 (External Dia, 3/Internal Dia, 5) BYCP5K-W Fresh white 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X ,00 3, /.5/0 3/.5/0 30/8.5/7 30/8.5/ phase, 0-40 V/0 V, 50/60 Hz 4,000 7, /406/ /406/ /459/ /477/388 67/583/477 74/636/530,30/98/706,65/989/794 3/9/ ,000, // ,300 7, /3/ ,000 34, /3/ 6/3.5/ 9/6.5/3.5 /8/5 36/33.5/3 43/37.5/ ,000 39,600 49, ,800 3,800 4, ,500 54, / / / / / / / / / / / / / / / /0.00 Ceiling Mounted Cassette (Compact Multi Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) Sound level (H/L) Gas (Flare) Panel (Option) 30 V, 50 Hz- 40 V, 50 Hz- 0 V, 60 Hz Model Colour Weight (*) (*) (*) db(a) FXZQ0MVE,000 7,800.3.,00 8, / / /7 38/47 30/5-3/6-3/9 55X700X700.7 FXZQ5MVE -phase, 0-40 V/0 V, 50 Hz/60 Hz,500 9, ,800 0, / / /7 38/47 30/5-3/6-3/9 Galvanised steel plate VP0 (External Dia, 6/Internal Dia, 0) 55X700X700.7 FXZQ3MVE 3/6/ /8/.5 44/39/34 Note: Specifications are based on the following conditions; : Indoor temp.: (*)7 CDB, CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 7 CDB, 9 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 0 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 3,00, ,400 3, / /0.073 / /65 3/6-34/8-33/9 86X575X575 8 BYFQ60B8W White (6.5Y/0.5) 55X700X700.7 FXZQ40MVE 4,000 6, ,300 7, / /0.088 /8 388/8 36/8-37/9-36/30 55X700X FXZQ50MVE 5,000 9, ,400, / /0. 4/0 493/353 4/33-4/35-4/34 55X700X700.7 Ceiling Mounted Cassette (Double Flow) capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) 0 V Sound level (H/L) 40 V Ceiling Mounted Cassette Corner capacity capacity (50 Hz/60 Hz) Airflow rate (H/L) Gas (Flare) Panel (Option) Model Colour Weight 50 Hz 60 Hz 0 V Sound level (H/L) 40 V Gas (Flare) Model Panel Colour (Option) Weight (*) (*) (*) db(a) (*) (*) (*) db(a) FXCQ0MVE FXCQ5MVE FXCQ3MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ5MVE,000 7,800 9,900,600 6,000 9,800 4,900 3,700 49, ,00,800 3,400 4,300 5,400 6,900 8,600 3,800 8, /5 FXKQ5MAVE,500 9,900.9,800 0, /9 FXKQ3MAVE 3,00, ,400 3, Galvanised steel plate FXKQ40MAVE 4,000 6, ,300 7, FXKQ63MAVE 6,300 4, ,900 7, /9 3/0 8/5 388/38 388/38 459/ /530 38/33 38/33 40/34 4/37 40/35 40/35 4/36 44/39 5X,0X X,40X phase, 0-40 V/0 V, 50/60 Hz 0.066/ / / / / / / /0.00 /8.5 /8.5 3/0 8/3 388/ / / /459 5X,0X70 3 VP5 (External Dia, 3/Internal Dia, 5) BYK45FJW 70X,40X Galvanised steel plate 47/77 3/7 34/9 38/30 34/8 36/30 38/30 34/8 36/30 44/38 34/9 37/3 44/38 34/9 37/3 58/459 37/3 39/34 98/74 39/34 4/36,65/883 44/38 46/40 305X775X X775X X775X X990X X990X X,75X X,665X X,665X X,030X ,500 0, /6.5 6 BYBC3G-W 53X,030X phase, 0-40 V/0 V, 50/60 Hz 3,00 3, /6.5 6 VP5 (External Dia, 3/Internal Dia, 5) 53X,030X ,000 7, /9 3 BYBC50G-W White (0Y9/0.5) 53X,45X ,000, /9 3 53X,45X White (0Y9/0.5) 5X,0X X,40X ,300 7, /3 35 BYBC63G-W 53X,430X680 8,000 34, / 47 53X,90X680.0 BYBC5G-W 5X,30X70 34 BYK7FJW 70X,440X800,500 54, / / / / / / / / / / / / / / / / / X,90X680 Note: Specifications are based on the following conditions; : Indoor temp.: (*)7 CDB, CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 7 CDB, 9 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 0 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions..0 6

15 SPECIFICATIONS 7 Slim Ceiling Mounted Duct (700 width type) capacity capacity (FXDQ-PBVE: 50 Hz/60 Hz) (FXDQ-PBVET: 50 Hz/60 Hz) Airflow rate (HH/H/L) with drain pump without drain pump External static pressure Sound level (HH/H/L) 3 Gas (Flare) (*) (*) (*) Pa db(a) FXDQ0PBVE FXDQ5PBVE FXDQ3PBVE FXDQ0PBVET FXDQ5PBVET FXDQ3PBVET,000 7,800.,00 8,500,500 9,900,800 0,900 Galvanised steel plate 3,00,600 3,400 3, / / / / / / /7./ 8/54/6 -phase, 0-40 V/0 V, 50/60 Hz /7./ 8/54/6 8.0/7./ 8/54/6 33/3/9 33/3/9 33/3/9 00X700X / / / / / / X700X60 3 VP0 (External Dia, 6/Internal Dia, 0) 00X700X60 Slim Ceiling Mounted Duct (900/,00 width type) capacity capacity (FXDQ-NBVE: 50 Hz/60 Hz) (FXDQ-NBVET: 50 Hz/60 Hz) Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 3 with drain pump without drain pump (*) (*) (*) Pa db(a) 4,000 6,000 4,300 7,00 -phase, 0-40 V/0 V, 50/60 Hz 5,000 9,800 5,400,500 Galvanised steel plate FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE FXDQ40NBVET FXDQ50NBVET FXDQ63NBVET 6,300 4, ,900 7, / / / / / / / / / / / / //8.5 37/335/300.5/.0/0.0 44/388/ /4.5/ /5/459 34/3/30 35/33/3 36/34/3 00X900X X900X X,00X60 Gas (Flare) VP0 (External Dia, 6/Internal Dia, 0) Note: Specifications are based on the following conditions; : Indoor temp.: (*) 7 CDB, CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 7 CDB, 9 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 0 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 0 Pa for FXDQ-PB models and 5 Pa for FXDQ-NB models.) : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 db(a). 3: Values are based on the following conditions: FXDQ-PB external static pressure of 0 Pa; FXDQ-NB: external static pressure of 5 Pa. 3 Ceiling Mounted Duct capacity capacity (50 Hz/60 Hz) Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Gas (Flare) capacity capacity (50 Hz/60 Hz) -phase, 0-40 V/0 V, 50/60 Hz FXMQ40PVE 6,000 FXMQ50PVE Note: Specifications are based on the following conditions; : Indoor temp.: (*) 7 CDB, CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. 7 CDB, 9 CWB, Outdoor temp.: 35 CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. : Indoor temp.: 0 CDB, Outdoor temp.: 7 CDB, 6 CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. : External static pressure can be modified using a remote controller that offers seven (FXMQ0-3P), thirteen (FXMQ40P), fourteen (FXMQ50-5P) or ten (FXMQ40P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ0-3P and 00 Pa for FXMQ40-40P. 4,000 7, / / / / / / / / / /0.03 Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) (*) (*) (*) FXMQ0PVE,000 7,800.3.,00 8,500 9/7.5/6.5 Galvanised steel plate 4,300 38/65/30 38/65/30 335/8/47 565/459/ /58/530 Pa db(a) 33/3/9 33/3/9 34/3/30 39/37/35 4/39/37 300X550X700 5 FXMQ5PVE,500 9, ,800 0,900 9/7.5/ X550X700 5 FXMQ3PVE 3,00, ,400 3,600 /8/7 300X550X X700X700 8 VP5 (External Dia, 3/Internal Dia, 5) FXMQ63PVE FXMQ80PVE FXMQ00PVE FXMQ5PVE 6,300 4, ,900 7, / / / / / / / /0.449 Gas (Flare) (*) (*) (*) 300X,000X ,000 3,700 8,600 34,00 300X,000X phase, 0-40 V/0 V, 50/60 Hz 0,000 39,600 0,800 4,700 Galvanised steel plate 300X,400X VP5 (External Dia, 3/Internal Dia, 5) 5,000 9,800 5,400,500 6/3/ 8/6.5/5,500 49,500 3,800 54,600 /7.5/6 5/.5/0 3/7/3 39/33/8 300X,400X X,000X FXMQ40PVE 4,300 57, ,500 6, /68/ /794/706,30/953/8,377/,65/988,64/,377/,30 Pa db(a) 4/40/38 43/4/39 43/4/39 44/4/40 46/45/ / / /39/3 300X,400X

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz

COOLING ONLY HEAT PUMP PCV0612F. Cooling Only 50 Hz/60 Hz. Heat Pump 50 Hz/60 Hz Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of

E 1E. small offices and shops. The ideal air conditioning system for. 5S+1E concepts of The ideal air conditioning system for small offices and shops Extending the core 5S concept Space saving, Sufficient capacity, Slim design, Soundreduced operation and Single phase power supply Daikin s

More information

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV1217. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV1217 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV0915 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings

PCV0915. Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz. A system with the high capacity needed to suit large-sized buildings PCV0915 Cooling Only 50 Hz Heat Pump 50 Hz/60 Hz A system with the high capacity needed to suit large-sized buildings Benefits for property OWNERS With Daikin's proprietary inverter technology and cutting-edge

More information

PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to

PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to Warning PCV1009A Daikin products are manufactured for export to numerous countries throughout the world. Prior to product conforms to the applicable standards, and is suitable for use, in the region where

More information

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz

PCVAU0828B WATER COOLED INVERTER SERIES. HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz PCVAU0828B WATER COOLED INVERTER SERIES HEAT PUMP 50 Hz HEAT RECOVERY 50 Hz A water cooled intelligent individual suitable for tall multi-storeyed build This unique system can perform as heat pump or heat

More information

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings

Single outdoor unit series suitable for homes, offices, shops, and middle-sized buildings PCV3 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,

More information

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type PVVAU1722 Preview 50 Hz Ceiling Mounted Cassette ( Round Flow with Sensing ) Type FXFSQ-AVM Round flow Circulation Airflow Evenly Distributes Cool Air Circulation Airflow P.5 Indoor unit lineup Ceiling

More information

OOL ING ONL Y HE AT P UM P PCV0612C. C ooling Only 50 Hz/60 Hz. Heat P ump 50 Hz/60 Hz

OOL ING ONL Y HE AT P UM P PCV0612C. C ooling Only 50 Hz/60 Hz. Heat P ump 50 Hz/60 Hz Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and

More information

VRVIV-0117-E. Cooling Only 50 Hz

VRVIV-0117-E. Cooling Only 50 Hz VRVIV-0117-E Some model names might differ and some products might not be available depending on the country of sale. For further information, please contact one of our sales companies. Cooling Only 50

More information

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz

FOR REPLACEMENT USE PCV1213. Cooling Only 50 Hz Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and

More information

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz

W SERIES. PCVMT1603aprv WATER COOLED SYSTEM. Cooling Only 50 Hz PCVMT1603aprv Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

PVVVN1325aprv. PCVAU1327 Preview. Cooling Only / Heat Pump 50 Hz

PVVVN1325aprv. PCVAU1327 Preview. Cooling Only / Heat Pump 50 Hz PVVVN1325aprv PCVAU1327 Preview Only / Heat Pump 50 Hz Next Generation VRV IV System First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for over 30 years. Now, Daikin

More information

VRV systems. Superior heating under low temperature conditions

VRV systems.   Superior heating under low temperature conditions VRV systems www.daikin.eu Superior heating under low temperature conditions ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality

More information

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your PCRMY1204 A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your lifestyle. Both series of Daikin air conditioners

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz Service Manual RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz R-410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi 1.2 PREFACE...x Part 1 General Information... 1 1. Model Names of Indoor/Outdoor

More information

PCV0320. Quieter, Smaller, Sleeker, Simpler: The is now four times better. Even earth friendly with a higher COP.

PCV0320. Quieter, Smaller, Sleeker, Simpler: The is now four times better. Even earth friendly with a higher COP. Cautions 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V PLXRMM1606B Wall Mounted FTN-A Series COOLING ONLY [50Hz] 220-240V ELEGANT, EFFICIENT 1 Daikin s FTN-A series wall mounted air conditioner that not only saves energy but also ozone friendly. Stylish Flat

More information

PCR0709A. Options. Indoor unit

PCR0709A. Options. Indoor unit Indoor unit No. 1 2 3 4 Item 5-room centralised controller Wiring adaptor for time clock/remote controller (Normal open pulse contact/normal open contact) Titanium apatite photocatalytic air-purifying

More information

DAIKIN Modular Inverter Air Cooled Chiller

DAIKIN Modular Inverter Air Cooled Chiller DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION What is Daikin VRV IV S-series? One flexible package Daikin VRV IV S-series

More information

Inverter Wall Mounted

Inverter Wall Mounted PLXRHK1603 Inverter Wall Mounted FTKS-A Series COOLING ONLY What is inverter technology? Inverter system ensures faster cooling with signifi cant energy saving. Moreover, it helps to maintain consistent

More information

The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve PCRSG0716C The Comfort and Luxury You Deserve Multi-Split Type Air Conditioners With DC Inverter and Swing Compressor Cooling Only [50 Hz] Air condition your entire home with a single outdoor unit. If

More information

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type Si001158 REMOVAL PROCEDURE S E R V I C E M A N U A L 2.5/3.2/3.5 kw Class Outdoor Unit Inverter Pair Type Service Manual Removal Procedure Outdoor Unit Applicable Models Heat Pump RXS225KC RXS232KC RXS225KCG

More information

The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and

More information

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type Si121174 REMOVAL PROCEDURE S E R V I C E M A N U A L 4.0/5.0/5.2/5.8/6.8/7.5 kw Class Outdoor Unit Inverter Multi Type Service Manual Removal Procedure Outdoor Unit Applicable Models Cooling Only 3MKS50E3V1B

More information

Quick & High Quality replacement

Quick & High Quality replacement PCVMT1619aprv Quick & High Quality replacement For Replacement Use Cooling Only 50 Hz Reusing existing piping for speedy replacement to an advanced energy-saving air conditioning system SERIES Upgrading

More information

VRV IV S-series heat pump

VRV IV S-series heat pump VRV IV S-series heat pump The most compact VRV Most compact unit on the market 3mm high & kg Control systems Indoor units VRV type indoor units Residential type indoor units (such as Daikin Emura) Air

More information

FBQ. DC Duct Heat Pump or Cooling Only

FBQ. DC Duct Heat Pump or Cooling Only FBQ DC Duct Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FBQ DC Duct systems offer a powerful solution, compact in design and easily concealed in a ceiling. With both cooling only and heat

More information

Split Type Air Conditioners

Split Type Air Conditioners PCRMY1450 Split Type Air Conditioners DC Inverter Control 50 Hz Urusara 7 FTKJ Series FTKV Series FTKC Series Urusara 7 FTKJ Series Lineup of DC Inverter Air Conditio Daikin is the sole manufacturer to

More information

LV Series. SEER 15+ Concealed Built in Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump LV Series SEER 15+ Concealed Built in Heat Pump EXPERTISE AND INNOVATION Daikin s slim duct systems offer a built in solution with the benefits of duct free technology. Installed similar to a traditional

More information

Product. ortfolio. Integrated climate control

Product. ortfolio. Integrated climate control Product ortfolio Integrated climate control Portfolio Outdoor unit range Capacity (HP) System Product name 4 5 6 8 0 4 6 8 0 RYYQ-T Heat pump with continuous heating () () () RXYQ-T Heat pump without continuous

More information

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz]

PCRAU0726F. Multi-Split Type Air Conditioners L Series with DC Inverter Power Control Cooling Only & Heat Pump [50 Hz] Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

FAQ. Wall Mount Heat Pump or Cooling Only

FAQ. Wall Mount Heat Pump or Cooling Only FAQ Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FAQ wall mount SkyAir systems feature streamlined indoor units in both cooling only and heat pump models. Sleek and sophisticated

More information

. Creating Maximum Comfort

. Creating Maximum Comfort P P r o d u c t E X P L A N A T I O N M M a i n F E A T U R E S AA. Creating Maximum Comfort 1 Inverter technology The linear VRV system makes use of a variable Proportional Integral (PI) control system

More information

Quick & High Quality replacement

Quick & High Quality replacement VRVIVQ-1216-A Quick & High Quality replacement For Replacement Use Cooling Only 50 Hz Reusing existing piping for speedy replacement to an advanced energy-saving air conditioning Upgrading air conditioning

More information

LV Series. SEER 20+ Wall Mount Heat Pump

LV Series. SEER 20+ Wall Mount Heat Pump LV Series SEER 20+ Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s SEER 20+ single split systems feature wall mounted units with a sophisticated appearance and a flat panel design. Packed with high

More information

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz

SiBE39-402A. Service Manual. R-410A Heat Pump 50Hz SiBE3-402A Service Manual R-410A Heat Pump 50Hz SiBE3-402A R410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi Part 1 General Information... 1 1. Model Names of Indoor/Outdoor Units...2

More information

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT PORTFOLIO

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS PRODUCT PORTFOLIO ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 10.15 PRODUCT PORTFOLIO What is Daikin VRV? One flexible package Daikin VRV is a modular, commercially applied airconditioning and heating system

More information

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz 201812 Engineering Data Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V Heat Pump 60 Hz Heat Recovery 60 Hz RWEQ-TATJU (208 / 230 V, 60 Hz) RWEQ-TAYDU (460 V, 60 Hz) RWEQ-TAYCU

More information

Energy-saving operation

Energy-saving operation DC Inverter can attain both comfort a Energy-saving operation All the models of Panasonic FS Inverter Series are equipped with DC inverters for the higher EER operation. The new design attains quiet and

More information

The Multi-talented VRV-S.

The Multi-talented VRV-S. Revolutionary comfort. Anywhere and everywhere. The Multi-talented VRV-S. R-410A INVERTER Light commercial :: Residential :: Renovation :: New Construction The singular pursuit of Absolute Comfort. Daikin

More information

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,

More information

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi Warning Daikin Industries, Ltd. s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and

More information

Up to SEER 26.1 Wall Mount Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump Up to SEER 26.1 Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s Quaternity system incorporates technological innovations that deliver features and benefits superior to traditional mini split systems.

More information

Daikin Inverter Ducted Systems

Daikin Inverter Ducted Systems Daikin Inverter Ducted Systems A traditional central-air system made better with Daikin Constant Comfort inverter technology. The Daikin Inverter Ducted line is a cost-effective alternative to traditional

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM. SHOPS MULTI SYSTEM RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM 2009 www.daikin.co.uk ABOUT DAIKIN Daikin UK is a leading supplier of heating, cooling and refrigeration solutions for commercial, residential

More information

R410A RZR-0916-C Authorized dealer: Catalogue No. PCSMY1546 Tel: Tel:

R410A RZR-0916-C Authorized dealer: Catalogue No. PCSMY1546 Tel: Tel: RZR-0916-C www.daikin.com.my Authorized dealer: Head Office: Tel: 03-7953 8388 Branches: Fax: 03-7956 4371 Kedah Tel: 04-730 5670 Penang Tel: 04-331 1670 Perak Tel: 05-548 2307 Negeri Sembilan Tel: 06-768

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Product. ortfolio. Integrated climate control

Product. ortfolio. Integrated climate control Product ortfolio Integrated climate control Portfolio Outdoor unit range Capacity (HP) System Product name 4 5 6 8 0 4 6 8 0 Cooling capacity (kw).6 4.0 5.5.4 8.0.5 40.0 45.0 49.0 55.9 Heating capacity

More information

The Comfort and Luxury You Deserve

The Comfort and Luxury You Deserve PCRAU0644C The Comfort and Luxury You Deserve Multi-Split Type Air Conditioners E series With DC Inverter and Swing Compressor Only & Heat Pump [50 Hz] Air condition your home with a single outdoor unit.

More information

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design VRF system for medium sized buildings SMALL OFFICES Compact Design For Light Commercial Buildings Perfect total air conditioning systems with features of energy saving, low noise, comfortable airflow,

More information

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz

SiE Service Manual. RXYQ5-48MAY1 R410A Heat Pump 50Hz SiE39-40 Service Manual RXYQ5-48MAY1 R410A Heat Pump 50Hz SiE39-40 R410A Heat Pump 50Hz 1 Introduction vi 11 Safety Cautions vi 12 PREFACE x Part 1 General Information 1 1 Model Names of Indoor/Outdoor

More information

EPCE03-06D. The Next Generation of Air Conditioning Systems

EPCE03-06D. The Next Generation of Air Conditioning Systems EPCE03-06D The Next Generation of Air Conditioning Systems T a b l e o f TC O N T E N T S INTRODUCTION Who is Daikin? p 4 The history of VRV systems p 6 WHAT IS? p 8 THE INTELLIGENT AIR CONDITIONING SYSTEM

More information

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR Comfort We offer a wide range of products, and always provide you with

More information

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only KE Series SEER 14+ Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s SEER 14+ single split systems feature streamlined, wall-mounted indoor units paired with quietly compact outdoor

More information

VRV HEAT RECOVERY

VRV HEAT RECOVERY PART 1: GENERAL 1.01 SYSTEM DESCRIPTION A. The variable capacity, heat pump heat recovery air conditioning system shall be a Daikin VRF (Variable Refrigerant Flow) AURORA system for cold climate installation,

More information

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL PRODUCT LINEUP VRF For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL 100 AIRSTAGE VRF Systems can be designed to create an air conditioning solution to suit most building requirements. AIRSTAGE VRF Systems

More information

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU1117

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU1117 HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU1117 THE BEST AIR ANYWHERE At Daikin, we're not just in the business of air conditioners. We're in the business of human comfort. Our passion for designing

More information

EDUS M. General Information. RXYQ-TYDN 3 phase, 460V, 60Hz. RXYQ-TTJU 3 phase, 208/230V, 60Hz

EDUS M. General Information. RXYQ-TYDN 3 phase, 460V, 60Hz. RXYQ-TTJU 3 phase, 208/230V, 60Hz EDUS341411-M General Information RXYQ-TYDN 3 phase, 460V, 60Hz RXYQ-TTJU 3 phase, 208/230V, 60Hz EDUS341411-M General Information... EDUS341411-M (This booklet) Indoor Units Ceiling Mounted Cassette Type

More information

HEATING AND COOLING SOLUTIONS DUCTED HEAT PUMPS PCDUNZ0717

HEATING AND COOLING SOLUTIONS DUCTED HEAT PUMPS PCDUNZ0717 HEATING AND COOLING SOLUTIONS DUCTED HEAT PUMPS PCDUNZ0717 THE BEST AIR ANYWHERE At Daikin, we're not just in the business of heat pumps. We're in the business of human comfort. Our passion for designing

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135 124 OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135 Water-Cooled VRV RWEYQ-MY1 136 INDOOR UNITS 1. Cassette

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................

More information

Inventor of the Inverter Digital Inverter System

Inventor of the Inverter Digital Inverter System Inventor of the Inverter Digital Inverter System Inventor of the Inverter The Digital inverter from Toshiba combines economy and ecology in a smart body. It offers state-of-the-art technology, exceptional

More information

PCH0601 HE A T R E CLA IM V E N T ILA T ION

PCH0601 HE A T R E CLA IM V E N T ILA T ION Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock,

More information

3 rd Generation of VRV. The professional solution for your professional project

3 rd Generation of VRV. The professional solution for your professional project 3 rd Generation of VRV The professional solution for your professional project CONTENT What is VRV? Definition, History, Concept VRVIII Range Outdoor units, indoor units. VRVIII features Piping limits,

More information

Concealed ceiling units

Concealed ceiling units Concealed ceiling units Daikin concealed ceiling units an invisible improvement to any space Why choose Daikin? Daikin is a world leader in air conditioning and heating. So no matter what your needs, you

More information

Daikin Airconditioning UK Ltd

Daikin Airconditioning UK Ltd Daikin Airconditioning UK Ltd Daikin Europe N.V. p. 02 Daikin has a worldwide reputation based on over 70 years experience in the successful manufacture of high quality air conditioning equipment for industrial,

More information

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147 140 OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 140 RXYQ5-54P7W1B(A) 142 RXYQ16-36P7W1B 144 RXYSQ4-6PA7Y1B 145 RXYSQ4-6PA7V1B 146 RXQ5-18P7W1B(A) 147 Water-Cooled VRV RWEYQ-MY1 148 INDOOR UNITS 1. Cassette

More information

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool Air Conditioning Product Brochure 2015/2016 Classic Series Hi-Wall Split Systems Everyday Cool 3 Everyday Innovation We design with you in mind. You ll find that Haier Air Conditioning units are quiet,

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Inverter Ducted Systems About Toshiba s Inverter Ducted systems. Toshiba s Inverter Ducted systems allows you to air condition your home without having to install the indoor

More information

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER FBQ SERIES HEATING AND COOLING SYSTEMS DC DUCT CONCEALED Indoor Unit FBQ18PVJU FBQ24PVJU

More information

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517 HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517 THE BEST AIR ANYWHERE At Daikin, we're not just in the business of air conditioners. We're in the business of human comfort. Our passion for designing

More information

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-100 FDQ-C TABLE OF CONTENTS FDQ-C 1 Features............................................................. 2 2 Specifications.......................................................

More information

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517

HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517 HEATING AND COOLING SOLUTIONS DUCTED SYSTEMS PCDUAU0517 THE BEST AIR ANYWHERE At Daikin, we're not just in the business of air conditioners. We're in the business of human comfort. Our passion for designing

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING

VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING VRV LIFE FLEXIBLE / DUAL-FUEL HEATING / INVERTER TECHNOLOGY / QUIET / SPACE-SAVING DAIKIN VRV LIFE Re-inventing residential air-conditioning by breaking technological barriers, Daikin VRV LIFE systems

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling Ceiling suspended unit Energy label:» Up to class A Seasonal efficiency, optimized for all seasons Heat pump system Installation possible in new and existing buildings

More information

Air conditioners, heating & cooling for shops,restaurants and offices

Air conditioners, heating & cooling for shops,restaurants and offices Air conditioners, heating & cooling for shops,restaurants and offices 4-way blow ceiling suspended unit air to air heat pumps www.daikin.eu FUQ-B made by daikin : WORLD-FAMOUS FOR EFFICIENCY By purchasing

More information

FTQ. Daikin Inverter Ducted Heat Pump

FTQ. Daikin Inverter Ducted Heat Pump FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative

More information

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value. Midea Ducted and Cassette Split Systems Maximum versatility, maximum value. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.

More information

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER FHQ SERIES HEAT PUMP AND COOLING ONLY SYSTEMS CEILING-SUSPENDED CASSETTE Up

More information

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER FTQ SERIES HEATING AND COOLING SYSTEMS MULTI-POSITIONAL AIR HANDLER Up to

More information

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System For Residential & Light Commercial Applications 4 Ton 8 Zone Multi Split Heat Pump System EXPERTISE AND INNOVATION The Super Multi PLUS Split System is the ultimate, flexible solution for individual zone

More information

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling Air Conditioners Heating & Cooling C o n c e a l e d C e i l i n g U n i t Energy label:» Up to class A Heat pump system Seasonal inverter technology Flexible duct system for large areas Neatly concealed»

More information

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems Technology that works fast Ducted Systems About Toshiba s Ducted systems. Combining high power with high efficiency. Toshiba s Ducted systems allows you to air The Toshiba Air Conditioning DC Hybrid. The

More information

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFAA2VEB > FFAA2VEB TABLE OF CONTENTS FFA-A 1 Features............................................................. 2 2 Specifications.......................................................

More information

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Si71-812 Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1 Heat Reclaim Ventilation - with DX coil - VKM 50GAV1 VKM 80GAV1

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information