CRYOGENIC PRODUCTS SEB Series Trim Heater

Size: px
Start display at page:

Download "CRYOGENIC PRODUCTS SEB Series Trim Heater"

Transcription

1 SEB Series Trim Heater Cryoquip manufactures a new series of modular Trim Heaters. The new units are available for use with industrial gases such as Oxygen, Nitrogen, Argon, CO2 as well as other specialized gases. Improved features include: Removable and replaceable heater elements Low pressure drop Small footprint Lightweight and portable Electric Cryogen Trim Heater utilize high quality electric heating elements and stainless steel heat exchanger tubes. Heating elements and tubes are specially positioned in the highly conductive aluminum modules. Modules consist of multiple stainless steel tubes in parallel to provide low pressure drops. The electric trim heaters are made optionally for high purity applications which include electropolished tubing. SEB 1R SEB 2R SEB 3R SEB 4R SEB 6R SEB 8R SEB 10R SEB 12R Overall Length System Features Solid state temperature controller. Independent solid state auto resetting high-temperature switch controller. A separate manual/auto resetting high limit shutdown controller. NEMA 4 electrical control enclosure, door interlock handle. Individual electrical components UL recognized. CSA certified, IEC approved and CE stamped. Standard Options Available Low temperature solenoid shut-off valve NEMA 4x electrical control enclosure. ANSI, Mueller four-bolt or DIN Flange end connections. Design Data Standard maximum working pressure 450 psig (30 barg) : working pressures to 10,000 psig (6 barg) available. Pressure drops are based on 100 psig (6.9 barg) inlet Units available in multiple voltages (575V, 480V, 415V, 400V, 380V, 240V). Power requirements may vary slightly with each specific model. Consult factory for pricing and delivery. 5.03

2 Flow rate SCFH/Nm³/hr 5,000/130 10,000/260 15,000,395 20,000/ 25,000/657 30,000/7 40,000/1050 2/0.1 SEB-2R-8T6-10-X SEB 3R-12T6-15-X 5/0.4 SEB 1R-4T6-5-X SEB 1 R-4T6-5-X SEB 3R-12T6-15-X SEB 2R-8T6-10-X Pressure Drop 10/0.7 SEB 1R-4T6-10-X SEB 1 R-4T6-5-X SEB 2R-8T6-10-X SEB 5R-20T6-25-X *US Patent #5,251,452 Psi/bar Psi/bar Psi/bar Flow rate SCFH/Nm³/hr 80,000/ ,000/ ,000/ ,000/1840 SEB 4R-16T6-20-X SEB 4R-16T6-40-X 50,000/1315 SEB 4R-16T6-20-X Temprise ºF / Cº 84/47 42/23 75/42 104/58 84/47 Temprise ºF / Cº 7/26 105/58 52/29 140/78 108/60 72/40 54/30 Psi/bar 5/0/4 SEB 8R 32T6 80 X SEB 8R 32T6 40 X SEB 10R 40T6 100 X SEB 10R 40T6 50 X SEB 8R-32T6-80-X SEB 8R-32T6-40-X SEB 5R-20T6-50-X SEB 5R 20T6-25-X Psi/bar 10/0.7 SEB 6R 24T6 60X SEB 6R 24T6 30 X SEB 8R 32T6 80X SEB-5R-20T6-50-X SEB 5R-20T6-25-X SEB 6R-24T6-30-X SEB-4R-16T6-40-X SEB-4R-16T6-20-X UFV Uniflo Series Cryoquip s UFV Uniflo Series ambient air vaporizer is an entirely new, patented* concept in high-flow natural draft vaporizers, designed for ambient air vaporization of cryogenic fluids. The Uniflo vaporizer had significant advantages over conventional designs for high flow service. The heat transfer elements are connected in parallel, which eliminates the differential thermal gradients between extrusions. Counter flow heat exchange between the downward flow of air in natural convection and the upward flow of the cryogenic in the vaporizer improves the thermal performance substantially compared to conventional designs with the same surface area. Ice accumulates safely during continuous operation in the lower part of the vaporizer with ice free extrusions protruding out of the ice pack. The low ice build-up lowers the center of gravity and therefore, reduces structural requirements in meeting the Uniform Building Code (UBC). Description The UFV series feature Cryoquip s patented Uniflo configuration of all parallel flow offering the following advantages: Even thermal gradients. High-flow, low pressure drop design. Unique internal aid fluid distribution Ice forms safely at bottom of vaporizer. Better approach exit temperatures from pure counter flow design. Features High thermal efficiency Advanced integral design Manufactured in the USA Cleaned for oxygen service Patented Spar Link construction Proven Cryoquip heat transfer design Designed in accordance with the UBC and ASCE Seismic zone 4,100+mph wind available MAWP up to 580 psig (40 bar-g) standard Flow rates up to 304,000 SCFH (8,000 Nm³/hr) 5.04

3 Dimension A (Length) Dimension B (Width) Dimension C (Height) UFV-856-XXL40 UFV-864-XXL40 UFV-1264-XXL40 UFV-1272-XXL40 UFV-1280-XXL40 UFV-12-XXL Capacities Surface Area 8 hr Capacity 12 hr Capacity 16 hr Capacity 24 hr Capacity 48 hr Capacity 72 hr Capacity ft² m² UFV UFV 864 (XX) L UFV UFV UFV UFV Wide Space Ambient Air Vaporizers Series New, improved unitized construction yields the highest structural to cost ratio available, and precludes the use of welds that cannot be heat treated, thereby maintaining the greatest structural integrity. Employs the unique Cryoquip spar link design; an efficient attachment method that enhances load carrying capability, which maintains the highest level of structural integrity available in the industry, during all modes of transportations. Can be deployed or redeployed with ease since these units are capable of resting on a flat bed trailer without the need for added shipping pallets, support blocks, or other shipping pieces. Can be handled with a fork lift without the vaporizer sustaining damage. Can be tied down on a trailer without any additional crating provisions. Lifting eyes are provided to facilitate handling. Designed in accordance with the Uniform Building Code (UBC) and applicable sections of ANSI A Units available for seismic zone 4, and 100 mph (160 km/h) conditions with normal frost loading. Continuous service rating is permitted for operating periods 5 to 7 days, or longer under certain conditions, with greater frost/ice loading for freeze periods. 5.05

4 PTE LTD YEW CHEONG VAI 804 F VAI 806 FL 10 VAI 806 FL 12 VAI 812 F VAI 812 FL 12 VAI 812 FL 15 VAI 816 FL 10 VAI 820 FL 12 VAI 824 FL 12 VAI 830 FL 12 VAI 836 FL 12 VAI 836 FL 15 VAI 836 FL 18 VAI 836 FL 20 VAI 848 FL 12 VAI 848 FL 15 VAI 848 FL 18 VAI 848 FL 20 VAI 856 FL 12 VAI 856 FL 15 VAI 856 FL 18 VAI 864 FL 15 VAI 864 FL 18 VAI 864 FL 20 VAI 872 FL 20 VAI 872 FL 23 Increase ground clearance further enhances heat transfer by natural convection. Extra capacity. Each finned aluminum heat transfer element features eight fins which measure 8 inches (200 ) from tip to tip and provide high capacity performance and fast defrosting. Elements have approximately 5 square feet per foot length (1.5 square meters per meter length) of external heat-exchanger surface area. Low pressure drop, full-bore passages in the elements provides more flow cross section. Internal fins promote heat transfer with additional surface area. Heat transfer elements of heights to 23ft (7,010 ) are available to meet a range of process demands. Coon assembly configurations and ratings are shown on the reverse side. New, larger bore fluid pages are available to maintain ultra low pressure drops on high flow rate multiple element units. Dimensions Performance Data External Heat Approx Ratings L x W Transfer Area Weight KSCFH (Nm³/hr) ft² m² lbs kg inches 8-hours 1-day 3-days 5-7 day x21 31x21 31x21 46x46 58x46 69x46 58x69 102x91 102x91 650x x x x x x x x x x x x CHEONG (ASIAPAC) PTE LTD YEW CHEONG (ASIAPAC) PTE LTD For models to meet special requirements including other models for greatly extended operating periods; for low pressure drop requirements for these vaporizers and others; for pressure drops for 8 hour ratings- consult Cryoquip. Pressure drop is less than 10% for the 1 day rating, based on 150 psig (10.3 bar) inlet pressure for all models except the L-18 and L-20 series. The performance of ambient air vaporizers is subject to many factors. These include flow, duty cycle, ambient temperature, relative humidity, freeze period, altitude, wind, solar radiation, operating pressure and proximity to adjacent structures. The effects of average solar and wind conditions are not included in the above ratings. Ratings are based on mean ambient conditions of 70ºF (21ºC) and 70% relative humidity. Special conditions may vary considerably for a particular application, thereby affecting performance. Specification YEW CHEONG (ASIAPAC) PTE LTD YEW CHEONG (ASIAPAC) PTE LTD Module overall Heights; L-10:163 (4150), L-12:185 (4700), L-15:220 (5600) L-18:255 (6450), L-20:291 (7400),L-23:327 (8300) Working Pressure- Up to 500 psig (34.5bar) (All Aluminum Units) Options Available YEW CHEONG (ASIAPAC) PTE LTD YEW CH D YEW CHEONG (ASIAPAC) PTE LTD YEW CHEONG (ASIAPAC) PT 5.06 End Connections Standard: four bolt flange Optional: four bolt mates 1,1½, and 2 inch Special end connections available on special order. Stainless Steel or Monel lined for services up to 15,000psig (1,034bar) and for semiconductor industry applications. Complete piping module assembly packages for complete vaporizer/piping installation. YEW CHEONG (ASIAPAC) PTE LTD IAPAC) PTE LTD

5 VEC/VEB Series Electric Vaporizer Cryoquip manufactures a new series of NEMA 4 modular Electric vaporizers. The new units are available for use with industrial gases such as Oxygen, Nitrogen, Argon (model VEB), and Carbon Dioxide (model VEC) as well as other special fluids. Improved features include: Removable and replaceable heater elements Low pressure drop Smaller footprint Lightweight and portable Electric Cryogenic Vaporizer utilize high quality electric heating elements and stainless steel process tubes. Heating elements and tubes are specially positioned within the highly conductive aluminum wafer modules. Heat transfer is further enhance in vaporizer units by means of a spirovane turbulence promoter within each stainless tube, which also reduces fluid slugging and surging. Special Designs are available for low temperature gas exit vaporizers with controls to provide exit gas temperature near saturated vapor for special applications. The new VEC/VEB Electric vaporizer Series VEC-Carbon Dioxide Service VEB-Oxygen, Nitrogen, Argon Service VEx 1R 2T12 VEx 2R 3T12 VEx 2R 3T24 VEx 3R 4T24 VEx 4R 6T12 VEx 6R 8T12 VEx 10R 12T12 *Dimensions - () A 34.5 (877) B 24 () 24 () 24 () 24 () Standard/ Options Available Electronic digital controller Wafer module insulation Stainless steel enclosures ANSI, Mueller four-bolt or DIN flange end connections Explosion-proof Class 1, Div.2, Group D Alarm dry contacts ASME Code Certification Design Data Standard maximum working pressure 450 psig (31 barg); working pressures to 10,000 psig, (6 barg) available. 10psi (.7 bar) pressure drop at rated flow and 150 psig (10 barg) working pressure, except T24 O2 units have higher pressure drops. System Features Easy dial thermostatic temperature controller. Adjustable auto resetting over-temperature switch. Adjustable manual resetting high limit shutdown switch. NEMA 4 electrical control enclosure, door interlock handle. Non-overheating design during no-flow. Individual electrical components U.L. recognized, CSA certified and IEC approved. Replaceable heating elements. Units available for any voltage. Power requirements may vary slightly with each specific voltage. For pressure greater than 580 psig (40 barg) consult factory for proper model number. Specify operating pressure range. 5.07

Oxygen Rating Power SCFH Nm³ / hr kw 20,000 30,000 36,000 45,000 54,000 80,000 95, , , , , ,000

Oxygen Rating Power SCFH Nm³ / hr kw 20,000 30,000 36,000 45,000 54,000 80,000 95, , , , , ,000 Fan Assisted Series HAF and KAF Cryoquip fan-assisted units provide maximum heat exchange and high vaporization rates of liquid oxygen, nitrogen, argon, LNG and other cryogenic fluids. The heat exchange

More information

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

ACD s patented Sub-ZeroTM (SZ)

ACD s patented Sub-ZeroTM (SZ) Volume 9 No. 1 A Newsletter from Spring 1998 NPSH (PSIG) 10 ACD s patented Sub-ZeroTM (SZ) reciprocating pump designs continue to meet customer s needs in diverse markets. ACD recently developed the 3-SZGU

More information

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR ELECTRONIC MATERIALS GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR Continuous flow, point-of-use purified CO 2 gas at a low cost of ownership continuous flow, point-of-use

More information

Cryoquip was recently challenged by an industrial chemical

Cryoquip was recently challenged by an industrial chemical Volume 13 No. 3 A Newsletter from Cryogenic Industries Spring 2003 Cryoquip engineers a unique heat exchanger with very high thermal efficiency N1 N4 Cryoquip was recently challenged by an industrial chemical

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

Economical and simplified solutions that offer quality and optimum steam trap service.

Economical and simplified solutions that offer quality and optimum steam trap service. Economical and simplified solutions that offer quality and optimum steam trap service. It All Comes Down To Protection Regardless of the temperature and pressure characteristics of steam line drips or

More information

Call us today! (800)

Call us today! (800) PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 1005A-2005A SUGGESTED SPECIFICATIONS Catalog No.: 6000.63B Effective: 3-01-15 Replaces: 9-01-09 WATER-TUBE POOL HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes condensing,

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S SERIES PB, 29, 129Y AND 29S Economical and simplified solutions that offer quality and optimum steam trap service FEATURES 29S 29 Thermostatic traps Pressure assisted fail-open design Freeze proof Easy

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS INDUSTRIAL AIR AND INFRARED RADIANT HEATERS Portable Unit Heaters Portable electric heaters are available in radiant-heat or fan-forcedair designs.

More information

RA2000 Thermostatic Radiator Valves

RA2000 Thermostatic Radiator Valves Data Sheet RA2000 Thermostatic Radiator Valves Application regulate the flow of hot water or steam through free-standing radiators, baseboards or convectors in hot water and two-pipe low pressure steam

More information

Nuclear Electric Heating

Nuclear Electric Heating Nuclear Electric Heating Caloritech has exceeded the most demanding nuclear heating requirements for over 30 years. We design and manufacture products for nuclear applications in PWR, BWR and PHWR nuclear

More information

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web   Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 981-4500 Facsimile (805) 981-4501 I. Installation Instructions Installation And Operating

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 2503-4003 SUGGESTED SPECIFICATIONS Catalog No.: 2000.934A Effective: 04-01-14 Replaces: 06-01-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS XTHERM, TYPE P - MODELS 2505-4005 SUGGESTED SPECIFICATIONS Catalog No.: 6000.70 Effective: 09-15-16 Replaces: NEW WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes condensing, gas-fired

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 2000.932C Effective: 04-01-14 Replaces: 07-15-13 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS AIR COOLER Products COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS Overview Certifications API 614 - ISO VG 32 Mineral Oil Flushing Capabilities API 661 ASME U-Stamp ASME UM-Stamp

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises Helical Coil Heaters Hot Oil Heaters Booster Heaters CEI Enterprises Helical Coil Hot Oil Heaters Helical Coil Hot Oil Heaters Overflow Pipe Fill C Standard model without stack heat exchanger Stack Heat

More information

The Leaders in Heat Transfer. CRES MF Compact In-Line Electric Heater

The Leaders in Heat Transfer. CRES MF Compact In-Line Electric Heater The Leaders in Heat Transfer CRES MF Compact In-Line Electric Heater COMPACT, RAPID HEATING OF LIQUIDS, STEAM AND GASES FOR SEMI-CON, POWER GENERATION, FOOD SERVICE, CHEMICAL, INDUSTRIAL AND AND PHARMACEUTICAL

More information

PACKAGED COMMERCIAL WATERTUBE BOILERS

PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILERS PACKAGED COMMERCIAL WATERTUBE BOILER American Boiler Manufacturers Association 4001 N. 9 th Street, Suite 226 Arlington, VA 22203-1900 703/522-7350 2003, American

More information

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS MVB, TYPE WH - MODELS 503A-2003A SUGGESTED SPECIFICATIONS Catalog No.: 3500.952C Effective: 06-25-15 Replaces: 12-22-09 DIVISION 23 34 36.29 COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

More information

FE1 Explosion-Proof Electric Air Heaters

FE1 Explosion-Proof Electric Air Heaters Explosion-Proof Electric Air Heaters The heater core assembly is contained in a sturdy, epoxy-coated, 14-gauge steel cabinet which also carries the motor and fan assembly. Adjustable louvers allow directional

More information

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E) ECS Pre-Engineered Wall Mount PGEN-10/(PGEN-10E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Cabinet Dimensions: Weight Temperature Range: Power Supply: Power Consumption:

More information

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS MVB, TYPE H - MODELS 504A-2004A SUGGESTED SPECIFICATIONS Catalog No.: 2000.933C Effective: 06-25-15 Replaces: 12-21-09 DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

Air-Cooling Evaporators

Air-Cooling Evaporators Air-Cooling Evaporators Types of construction Circuit Configurations Methods of Refrigerant Feed Methods of Air Circulation Methods of Defrost Type of Construction Bare tube Finned Tube Plate-surface Bare

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Water heaters. B. Packaged water heating systems. C. Domestic water heat exchangers. D. Water storage tanks. E. Water softeners. F. Reverse osmosis equipment. G.

More information

FUEL-FIRED VERTICAL TUBELESS BOILERS

FUEL-FIRED VERTICAL TUBELESS BOILERS FUEL-FIRED VERTICAL TUBELESS BOILERS 4 60 P orizontal and Vertical Feedwater / Condensate Return Systems and Blow-down Tanks FULTON FUEL-FIRED VERTICAL TUBELESS BOILERS FULTON: AN INDUSTRY LEADER SINCE

More information

Revitalize Building Mechanical Systems (4619)

Revitalize Building Mechanical Systems (4619) SECTION 235216 FIRE-TUBE CONDENSING BOILERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS) MAXIFLO TM Overview MaxiFlo TM KM Series Metal Tube Rotameters are rugged, versatile and accurate variable area (VA) flow meter offering 2.0% full scale accuracy. It s based on simple and easy-to-understand

More information

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax A R R O W P N E U M A T I C S Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca. 93308 661-399-9569 fax 661-393-9654 F I L T E R S R E G U L A T O R S L U B R I C A T O R S A C C E S S O R I E S H E

More information

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. HVAC Math The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb. Math F. to C. Conversion = (f-32)*(5/9) C. to F. Conversion = C * 9/5 +

More information

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series DESICCANT AIR DRYERS BD + CD + CD series AIR TREATMENT, A CRUCIAL INVESTMENT WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often

More information

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

Phillips. HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants Phillips REFRIGERATION MECHANICAL PUMP RECIRCULATORS BULLETIN MPR-03E Engineering Data VALVES VESSELS SYSTEMS CONTROLS HORIZONTAL AND VERTICAL ASSEMBLIES For Ammonia (R-717) and Halocarbon Refrigerants

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

PACKAGED AIR COOLED Product Data Catalog

PACKAGED AIR COOLED Product Data Catalog PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES

More information

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000 s AV(W)0500 AV(W) The domestic hot water boiler shall be a Camus ADVANTUS TM model having a recovery capacity of gph (lph) at 100ºF (56ºC) for DHW The domestic hot water boiler shall be design certified

More information

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

"ESDDR" Series Electric Humidifier

ESDDR Series Electric Humidifier ESDDR-1 Deionized, Demineralized, or Reverse Osmosis Water "ESDDR" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is deionized,

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

clean, dry compressed air

clean, dry compressed air clean, dry compressed air Adsorption Air Dryers Air and gas purification have been at the core of Xebec adsorption technology since 1967. We have built, installed and continue to service over 9000 dryers.

More information

CLE SERIES Fluid heating for emergency eyewash stations

CLE SERIES Fluid heating for emergency eyewash stations Keltech Electric Tankless Water Heaters CLE SERIES Fluid heating for emergency eyewash stations Contents 2 Keltech Electric Tankless Water Heaters 3 CLE Series Overview 4 Standard Features 6 Optional Features

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing

More information

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.

More information

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT Products Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT s s s s s CA-10-W CA-10-R CF-3-W CF-3-A CE-3-W CE-3-A CLH-6-W CLH-3-A

More information

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters PACKAGED MARINE THERMAL FLUID (HOT OIL) HEATERS Packaged Marine Design Thermal Fluid (Hot Oil) Heaters For Heating Asphalt Barges, Tankers, And Any Other Application Requiring Dependable Heating 13 Models

More information

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS HI DELTA, TYPE WH - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 3500.932A Effective: 04-01-17 Replaces: 10-31-16 DIVISION 23 52 33.13 FINNED WATER-TUBE WATER HEATERS - GENERAL 1.1 SUMMARY A.

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E) ECS Pre-Engineered Wall Mount PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E) Specifications For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Cabinet Dimensions: Weight Temperature Range: Power Supply:

More information

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr) snowstorm filled ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2 3 ultra-high purity compressed air dryers flow capacity: 3-1110 scfm (5-1900 Nm 3 /hr) D 1 2

More information

Condensing Unit Installation and Operating Instructions

Condensing Unit Installation and Operating Instructions Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.

More information

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2 H 2 S Ex p Ex d The world s safest continuous H 2 S analyzer. The OMA continuously measures H 2 S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the power of collateral data to

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web    Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 520-8631 Facsimile (805) 520-8640 I. Installation Instructions CEXI ELECTRIC VAPORIZER

More information

Temptek Auxiliary Equipment

Temptek Auxiliary Equipment Temptek Auxiliary Equipment Mold Temperature Controllers - Water Units VT-275-LX VT Series Mold Temperature Controllers are used to process temperature control to 250 F. These units use an incoloy heater

More information

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products Chromalox PRECISION HEAT AND CONTROL Cold Weather Electric Heat and Control Products INDUSTRIAL COMFORT HEATERS INDUSTRIAL COMFORT HEATERS Chromalox electric comfort heaters provide efficient, economical

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Stars Management JLT SUBMITTAL EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series) Tel: 00971 (04) 457 2383 Fax: 00971 (04) 457 2382 P.O. Box: 25867 Dubai U.A.E. E-mail: info@starsmanagementjlt.com Website:

More information

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000 Section 10 Bulletin A -7 Pneumatech is proud to offer this range of reliable and innovative refrigerated air dryers. These dryers are a cost effective

More information

Yarway Narvik Steam Desuperheater Series 4300 TempLow

Yarway Narvik Steam Desuperheater Series 4300 TempLow For precise and economical control of steam temperature Features and benefits Easy installation Installation in straight, vertical or horizontal pipe. Minimal headroom is required for mounting Only standard

More information

Landfill & Digester Gas Dryers. Features and Benefits

Landfill & Digester Gas Dryers. Features and Benefits Landfill & Digester Gas Dryers Landfill gas is generated by the anaerobic decomposition of organic matter deposited in landfills. Digester gas is produced as a by-product of the digestion of sewage sludge.

More information

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH CE CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH Energy Savings and Environmental Benefits Due to its highly effective heating surface area and true counter-flow heat exchanger arrangement,

More information

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm Desiccant Air Dryers ABP Series Blower Purge Desiccant Air Dryer 70-8,000 scfm Since 1994, Aircel has been delivering quality, industry leading compressed air dryers and accessories for production lines

More information

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation Filtration Balston Membrane Nitrogen Generators Compressed Air Dryers 157 Parker Hannifin Corporation Membrane Air Dryers Provide Clean, Dry Compressed Air Offer a reliable, efficient, and economical alternative

More information

EP PURIFICATION. clean water through microplasma technology EP-PURE.COM

EP PURIFICATION. clean water through microplasma technology EP-PURE.COM 2018 EP PURIFICATION clean water through microplasma technology EP-PURE.COM ABOUT US EP Purification manufactures novel and environmentally-sound systems for the purification of water and air. Based on

More information

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer Smart Solutions for Drying Compressed Air Dual Tower Heat Reactivated Desiccant Air Dryer HR Heated HB Blower 800.943.794 www.engineeredairproducts.com Engineered Air Products Moisture in compressed air

More information

Refrigerant Valves/Accessories

Refrigerant Valves/Accessories Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating

More information

CONDENSING HIGH EFFICIENCY BOILERS

CONDENSING HIGH EFFICIENCY BOILERS Built by 3I Innovative Industrial Inc. ABS Series CONDENSING HIGH EFFICIENCY BOILERS ABS 1500-2000-2500-3000-4000MBH Cast aluminum heat exchanger 10 to 1 turndown ratio Honeywell Sola boiler control system

More information

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature 40-95 F Humidity < 80 % Particulates Pressure Gas and Noxious Vapors < 0.14 mg/scf 14.7 PSI NO ELECTRICAL DATA Mains voltage 400 Vac ± 10 % Frequency

More information

Thermal Fluid Heaters

Thermal Fluid Heaters Thermal Fluid Heaters Vertical Coil, Vertical Tubeless, Electric and Horizontal Sizes from 75,000 to 40,000,000 BTU/HR The heat transfer innovators. THERMAL FLUID FEATURES AND BENEFITS KEY FEATURES No

More information

SECTION HEATING BOILERS

SECTION HEATING BOILERS SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Selecting an Environmental Test Chamber

Selecting an Environmental Test Chamber Selecting an Environmental Test Chamber Eric Berchtold, Cincinnati Sub-Zero Cincinnati Sub-Zero Products, LLC 12011 Mosteller Road Cincinnati, Ohio 45241 513-772-8810 www.cszindustrial.com 1 Selecting

More information

Ronan Model X90 Series Point Level Monitor

Ronan Model X90 Series Point Level Monitor Ronan Model X90 Series Point Level Monitor For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing

More information

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Cast Line Heaters The Benefits of This Space Saving Electric Heater WHITE PAPER Cast Line Heaters The Benefits of This Space Saving Electric Heater Introduction Cast line heaters, or cast-in heaters, offer an alternative to the more common inline process heaters that have

More information

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most

More information

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call  2-1/2 Pipe Thread Heaters Pipe Thread Heaters Construction Features " -/" Pipe Thread Heaters Element bends repressed uniformly to insure electrical insulation integrity. One piece forging hex, thread and riser assures reliability.

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Weighing System Ronan Model X96S Series Weighing System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Capacities W E A R E F R I E N D L Y T O T H E E A R T H Gas Fired DOUBLE-EFFECT Chiller-Heater Absorption Principle Yazaki MG-Series

More information

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series Over 100,000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. If it is

More information

PureLine D. Technical Specification

PureLine D. Technical Specification ... Complete Range Model Maximum Disinfection Maximum Disinfection Min. Flange Approx Weight (kg) Capacity * (m 3 /hr) Capacity ** (m 3 /hr) T 10 Size Chamber Power Power 26mJ/cm 2 RED 120mJ/cm 2 RED (%)

More information

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2 I&M NUMBER: 316-42-15-1 Page: 1 _ Pre Installation Check to make sure that heater received is the same as that ordered. Elements may come in contact with each other during shipment. Minor adjustments to

More information

GB Condensing Gas Boiler

GB Condensing Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB12/90 condensing hot water boiler(s), suitable for induced draft

More information

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER PART 1 GENERAL 1.01 RELATED DOCUMENTS A. ANSI Z21.13 American National Standard for Gas-Fired Low Pressure Steam and Hot Water Boilers B. ASME Section

More information

Flanged Immersion Heaters

Flanged Immersion Heaters Flanged Immersion Heaters Are designed for use in tanks and pressurized vessels to heat both liquids and gases. They mate to a companion flange that is either welded to a tank wall or, for circulating

More information

TPF Series Ozone Generators

TPF Series Ozone Generators TPF Series Introduction The model TPF is modular series of medium frequency ozone generators employing the latest electronics. The generators are manufactured by Ozono Elettronica Internazionale (OEI)

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information