ECOJET GREASE LEVEL SENSOR

Size: px
Start display at page:

Download "ECOJET GREASE LEVEL SENSOR"

Transcription

1 ACO Passavant Installation guide ECOJET GREASE LEVEL SENSOR AUTHOR Kate Jennings DATE COMPLETED 8 August 2016 DATE COMPLETED V13 ACO Polycrete, Old Bathurst Road, Emu Plains, NSW 2750 Tel: Fax: sales@acoaus.com.au

2 Contents 1 GENERAL SAFETY CONSIDERATIONS INSTALLATION MAINTENANCE WATER AUTHORITY APPROVALS CONTACT INFORMATION

3 1 GENERAL The ACO Passavant EcoJet grease separator is designed for above ground installation only. EcoJet grease separators are designed to remove waste Fats, Oils and Grease (FOG) from commercial tradewaste from applications such as commercial kitchens and food processing factories. They are not anticipated for use in residential applications. When discharging tradewaste into the public sewer system, local water authority requirements must be adhered to. 2 SAFETY CONSIDERATIONS All work in installing and maintaining this grease separator shall comply with requirements of the relevant authorities. 2.1 Site handling Inspect the EcoJet upon delivery and prior to installation, check for damage that may have occurred during transportation or at the job site prior to installation. Grease separators can be extremely large. To avoid damage to the grease separator, ensure that correct equipment (e.g. forklift, crane or sling ropes) is available for proper unloading and manoeuvring on site. 2.2 Foreseeable misuse No substances that pollute the water or limit the functionality of the grease separator should be introduced into the grease separator. This is particularly important in regard to: Wastewater containing faeces Wastewater containing light liquid oil (e.g. petrol) Wastewater in which a considerable amount of stable emulsions is present (e.g. dairy) EcoJet is not designed for waste oil to be tipped into it and macerators must not be discharged into it. Note that only wastewater from specific fixtures from commercial kitchen and food processing facilities should be connected to the grease separator. Good work practices are vital to ensure the correct functioning of the grease separator. Before plates and dishes are washed, they should be scraped of food scraps into a bin. Waste oil must never be poured down the sink. It should be set aside and removed by an appropriate disposal company. 2.3 Owners responsibilities All work performed on the grease separator equipment is to be carried out by trained and approved personnel, in accordance with local water authority regulations. The owner is responsible for complying with the following points and must ensure that: The grease separator is in proper condition 3

4 Personnel are qualified and authorised to operate and maintain the grease separator Adequate personal safety equipment is used The grease separator is operated according to relevant regulations There is adherence to a scheduled maintenance program (as per individual tradewaste agreement with the local water authority) and faults are immediately repaired. Contact ACO in relation to repairs or replacement. Complete and legible operating instructions are displayed at the grease separator s site of installation and training is provided for relevant personnel 2.4 Workplace Health and Safety (WHS) Safety instructions are intended to prevent damage to equipment or injury to personnel and must be read before any maintenance is performed. All safety instruction labels must be replaced if they become detached or illegible Installed devices (e.g. baffles, inlet and outlet parts, etc.) are not load bearing, they must not be used as steps, footholds or resting places for cleaning equipment etc. Grease separators should be not be installed where a danger to health is possible from the grease separator leaking, blocking or surcharging 3 INSTALLATION The EcoJet grease separator must be installed in compliance with local water authority regulations, Safework Australia and all other codes of practice. Prior to installation, ensure that the local water authority approves each installation. Queensland Urban Utilities Water requirement Queensland Urban Utilities require a raising piece on each maintenance opening cut to increase overall height of separator by 100mm. Ensure two are installed with each grease separator part number South Australia Water requirement South East Water, City West Water, Yarra Valley Water, Melbourne Water requirement ACTEW requirement A cap is required on top of each baffle (inlet and outlet) to prevent surcharge. Ensure each grease separator is installed with a baffle cap on the inlet and outlet baffle. Water Corporation requirement Require a cap on top of the outlet baffle only. To suit EcoJet NS 3-4: To suit EcoJet NS :

5 Sydney Water requirement Sydney Water requires a certificate of compliance from a licensed plumber when a grease separator is being installed. 3.1 Sizing The correct sizing and regular emptying of a grease separator is vital to its correct and on-going function. 5

6 Each separator is supplied with a sticker on each side identifying the separator and size. 3.2 Location Ensure the location of the grease separator is positioned where a maintenance contractor can easily access for pump out. If in doubt, contact a grease removal contractor and obtain a written agreement that the grease separator is able to be serviced. To minimise sedimentation in long runs, grease separators should be installed as close to the source of the grease as possible. Due to hygiene, grease separators should not be installed directly in the kitchen. A hose tap fitted with a backflow prevention device must be located within 5 metres of the grease separator for cleaning purposes(as per AS/NZS 3500). All above ground grease separators require steps and a platform for maintenance purposes, in accordance with AS Installation The grease separator should be installed on level concrete. Before using the grease separator for the first time, fill with clean water. 3.4 Connecting pipes Connecting pipes and pipe materials should be installed in accordance with AS 3500 and local plumbing codes. The grease separator has moulded 110mmØ (for NS 3-4 models) or 160mmØ (for NS ), outlet and inlet points, marked respectively. A calming region of 10 metres of straight pipe is recommended upstream of the inlet to reduce turbulent wastewater from entering the grease separator and disrupting separation. Any angled pipes to the inlet should not exceed 45. Adequate backflow prevention must be in place. 6

7 Vent IO IWSP *IO: Inspection Opening *IWSP: Industrial Waste Sampling Point ACO Passavant can be used in conjunction with a number of different pipe materials. The most commonly used pipe materials are HDPE (High Density Polyethylene) and PVC (Poly Vinyl Chloride). These pipe materials have various connection methods. The most commonly used methods are detailed below. a) HDPE pipe HDPE pipe is commonly used in applications where the temperature of discharging water is high. There are three options available for connecting the ACO Passavant inlet and outlet with HDPE pipe: HDPE connector (left) Flexible coupling (middle) Flex seal shielded coupling (right) The HDPE connector (pictured left) allows the ACO Passavant inlet or outlet to be buttwelded to the connector, and the other end of the connector is a push-fit connection to the connecting HDPE pipe. Flexible couplings are designed to fit two pipes of a similar outside diameter together. The flexible connector (pictured middle) is placed over the inlet or outlet and over the connecting HDPE pipe. The stainless steel hose clamps are tightened to achieve the seal. Note: some authorities do not permit the use of flexible couplings in ground slabs. Alternatively, a flex seal shielded coupling (pictured right) can be used. This coupling is also a flexible coupling, but has a layer of stainless steel and is designed for below ground applications. Check manufacturers approvals for use in ground slab applications prior to use. b) PVC pipe PVC pipe is used in projects where cost requirements 7

8 exceed the importance of hygiene, heat and corrosion resistance. To connect the ACO Passavant inlet or outlet to PVC pipe, a flexible coupling can be used (pictured left). The flexible connector is placed over the inlet/outlet and over the connecting PVC pipe. The stainless steel hose clamps are tightened to achieve the seal. Note: some authorities do not permit the use of flexible couplings in ground slabs. Another option is a flex seal shielded coupling (pictured middle). This is also a flexible coupling, but has a layer of stainless steel and is designed for below ground applications. Ensure to check manufacturers approvals for use in ground slab applications prior to use. A slip coupling (pictured right) is another option for connecting PVC pipe below ground. The inlet/outlet push-fits into one end of the slip coupling and the connecting PVC pipe the other. This method can also be used in ground slabs. Please note, couplings are not supplied by ACO. 3.5 Sampling To test the quality of the influent and effluent, some water authorities have a requirement for an Inspection Opening/Industrial Waste Sampling Point (IWSP) to be installed at both the inlet and outlet of the grease separator. Pipe work must be a minimum DN100. Water Corporation requirement Refer to drawing HX for precise construction requirements of IWSP. 3.6 Flow distribution installation A flow distributor is available for ACO grease separators to evenly split flow into two correctly sized separators. To ensure the correct functioning of this, the Y branch flow distributor must be installed completely level within the pipework system. An access point for rodding must be installed directly upstream of the Y branch for maintenance purposes. This must be regularly maintained according to the maintenance plan to ensure the pipes run without blockage. 3.7 Disconnector Gully Disconnector gullies shall be installed where required in accordance to the local water authority. Refer to AS3500 part 2 for typical detail. Water Corporation requirement Refer to drawing HX for precise construction requirements of disconnector gully. 8

9 3.8 Ventilation A grease separator must be adequately ventilated at both the inlet and outlet pipe. The high level vent on the inlet line must terminate above the roofline and the vent from the outlet shall be installed to AS/NZS To fit the vent, use a hole saw to drill open the cap marked vent or SA Water vent connection. Fasten the vent pipe (minimum DN100) using a flexible coupling. 4 MAINTENANCE 4.1 Disposal and cleaning The cleaning interval must be agreed with the local water authority. Once this has been reached, the contents of the grease separator must be emptied, cleaned and refilled with cold water to recommence kitchen activity. This must be carried out by qualified, approved personnel. Before disposal and cleaning, kitchen operation must stop. The entire contents of the grease separator should be removed by a disposal truck with a suction hose through the maintenance openings. Once emptied, the tank must be cleaned manually using a hose/high pressure hose to completely remove the residual FOG from the walls of the grease separator. Scraping may also be required to achieve this. The cleaning water must also be removed from the grease separator. Finally, the grease separator must be refilled at least 2/3 of the entire volume with a hosepipe from an on-site water supply and lids re-fitted with clamp ring in place. It is possible to install a fixed pump-out line for on-going servicing of grease separators. Consult the local water authority prior to installation. Water Corporation requirement Only camlock fittings are to be used for the pump out line and no fixed suction lines to be installed. 4.2 General inspection A general inspection should be carried out regularly by qualified personnel including: Visual check of the grease separator and its connections Determination of levels of sludge and grease 9

10 If any defects are found during the check, these must be remedied without delay (refer to 2.3). 5 WATER AUTHORITY APPROVALS Please refer to for ACO Passavant water authority approvals. 6 CONTACT INFORMATION For queries, servicing assistance and spare parts, contact ACO. ACO Polycrete Old Bathurst Road Emu Plains NSW 2750 Australia e: sales@acoaus.com.au p:

Modular Grease Trap MGTA

Modular Grease Trap MGTA Modular Grease Trap MGTA and MGTA) Installation Requirements Installation Water Requirements Corporation Water Corporation 22 Ethel Ave Brookvale NSW 2100 Postal: PO Box 255 Collaroy NSW 2097 Freecall

More information

ACO Construction & Building Products

ACO Construction & Building Products ACO Construction & Building Products Light oil and sediment separator system ACO Environment Oleopator P Oil Water Separator Operating Guide 1. Installation 2. Initial set-up/commissioning 3. Operation

More information

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental

More information

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation

KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation KESSEL Grease Separator G according to EN 1825-1 NG 1,2, 4 - for underground installation

More information

Grease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator

Grease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator Chapter contents Separator for freestanding installation With complete disposal Mobile separator for food stall or marquee Basic design for disposal via the cover Extension stage 1 for disposal via direct

More information

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES INTRODUCTION Wastes like cooking oil, grease and food solids are produced by food outlets and services throughout the Timaru District every day. When this

More information

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330 GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual for the GT 120 Family and GT 330 2 INSTALLATION PLANNING It's all in the planning! For proper operation of the toilet you should consider

More information

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty TM INSTALLATION MANUAL 9506036 Wolfen Hob Mounted Sensor Tap with Internal Solenoid Installation Details Warranty WOLFEN INSTALLATION MANUAL Technical Information TM IF AFTER CHECKING THE INSTALLATION

More information

APPENDIX P FAT, OIL AND GREASE MANAGEMENT ISSUE A AUGUST 17. Appendix P

APPENDIX P FAT, OIL AND GREASE MANAGEMENT ISSUE A AUGUST 17. Appendix P APPENDIX P FAT, OIL AND GREASE MANAGEMENT ISSUE A AUGUST 17 Appendix P Fat, Oil & Grease (FOG) Management of Wastewater systems: Specification for Tenant Fit Out Introduction For sites involved in the

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,

More information

Installation plan Commercial Washing Machine PW 413 PW 418

Installation plan Commercial Washing Machine PW 413 PW 418 Installation plan Commercial Washing Machine PW 413 PW 418 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first

More information

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation

Grease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants

More information

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice One to Three Compartment Sink When planning a multiple fixture discharge into a single Big Dipper, establish the size unit required by following the method outlined in the sizing section of this manual.

More information

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Note: Zurn Grease Interceptors with grease recognizing sensors are efficient appliances designed to separate grease from water.

More information

Approved Basic Trade Waste Pre-treatment Products

Approved Basic Trade Waste Pre-treatment Products Approved Basic Trade Waste Pre-treatment Products Reviewed 05/02/2016 This list shows the basic pre-treatment devices approved by SA Water for connection to its sewerage system. Dischargers may choose

More information

Trade Waste in the Food Industry

Trade Waste in the Food Industry Trade Waste in the Food Industry Trade Waste Bylaw 2008 Contents Introduction... 1 Why is there a need to control the effects of waste discharged from food premises?... 2 Food Premises are required to

More information

Pear Kitchen Sink Tap

Pear Kitchen Sink Tap Pear Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

EuroPEK Oil Separator

EuroPEK Oil Separator www.wavin-labko.fi WAVIN-LABKO LTD Labkotie 1 FIN-36240 KANGASALA Tel: +358 20 1285 270 Fax: +358 20 1285 280 E-mail: tanks@wavin-labko.fi 01/04 EuroPEK Oil Separator Instructions for Installation, Operation

More information

FLECK 5600 WATER SOFTENER INSTALLATION

FLECK 5600 WATER SOFTENER INSTALLATION FLECK 5600 WATER SOFTENER INSTALLATION Discount Water Softeners recommends using a licensed plumber to install your water softener. The following installation instructions are for use with the water softener

More information

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps About Us Product Overview Extended Capacity Hydromechanical Grease Traps Endura XL 75 Models DGT75 598L Light Trafficable Lid DGT75P 598L Pedestrian Lid Industry leading separation efficiency based on

More information

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it.

Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. Managing your waste. To help businesses get rid of fats, oils, greases and leftover food correctly. Bin it don t block it. What s the problem? If fats, oils, greases and leftover food go down your drains,

More information

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET Safety Information: Take care when moving and using the Camping Toilet Ensure that

More information

Innovative, Compact Design

Innovative, Compact Design Innovative, Compact Design Easy, Effective Compliance What in the world is? The Thermaco, Inc. Trapzilla Supercapacity Grease Trap collects free-floating (non-emulsifed) grease & oils contained in kitchen

More information

Operation Manual R205BV, R209BV

Operation Manual R205BV, R209BV Operation Manual R205BV, R209BV 1 Safety Instruction The rotary evaporator is manufactured according to current methods and accepted safety regulations. However, risks still exist during the installation,

More information

Lifting Station Type ABS Sanimax

Lifting Station Type ABS Sanimax 1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents

More information

Grease Control Device Maintenance Recordkeeping

Grease Control Device Maintenance Recordkeeping Grease Control Device Maintenance Recordkeeping All food service establishments are required to keep maintenance records for their grease traps, interceptors, and mechanical grease control devices for

More information

BioMaster 250/350/600 BioMaster Thermo 250/350/600

BioMaster 250/350/600 BioMaster Thermo 250/350/600 Downloaded from www.watergardeningdirect.com BioMaster 250/350/600 BioMaster Thermo 250/350/600 A BMR0003 B BMR0004 2 BioMaster 250/350/600, BioMaster Thermo 250/350/600 C D BMR0021 BMR0022 3 Downloaded

More information

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions Parenzo Range Basin Mixer, Bath Filler & Bath Shower Mixer Assembly instructions We have designed these products with your enjoyment in mind. To ensure that they work to their full potential, they need

More information

NZTIWF TECHNICAL GROUP

NZTIWF TECHNICAL GROUP NZTIWF TECHNICAL GROUP Paper #001 Grease Trap Guidelines for NZ Trade Waste Officers 2017 Edition - Version 1 Page 1 CONTENTS Title Page # Introduction and Acknowledgements 3 Sizing Guide for New Installations

More information

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms GB Page 1-18 Product

More information

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4 Carmel Utilities, in accordance with the National Pretreatment Program set forth by E.P.A. regulations (40 CFR 403), has hereby enacted a program for the controlling of Fats, Oils, and Grease discharges

More information

Operating instructions

Operating instructions Operating instructions for automatic detergent dispensing unit AWD 10 To avoid the risk of accidents en - AU, NZ or damage to the appliance, it is essential to read these operating instructions before

More information

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS

More information

Approved basic trade waste pre-treatment products

Approved basic trade waste pre-treatment products Approved basic trade waste pre-treatment products Released: 7 September 2017 This list shows the basic pre-treatment devices approved by SA Water for connection to its sewerage system. Dischargers may

More information

EuroPEK Roo Oil Separator

EuroPEK Roo Oil Separator www.wavin-labko.fi WAVIN-LABKO LTD Labkotie 1 FIN-36240 KANGASALA Tel: +358 20 1285 270 Fax: +358 20 1285 280 E-mail: tanks@wavin-labko.fi 01/04 EuroPEK Roo Oil Separator Instructions for Installation,

More information

EVAPOCYCLE OWNERS MANUAL

EVAPOCYCLE OWNERS MANUAL EVAPOCYCLE OWNERS MANUAL Introduction. The Aim of this manual to provide information to the property owner or occupant of the land on which an Evapocycle System has been constructed to insure that the

More information

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL English only (Australia and New Zealand) 1a 1 1b 1 1c 11 3 1 17 3 13 4 1 7 14 1 0 1 7174 Rev C www.insinkerator.com 01 InSinkErator, a business unit of Emerson

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE 1 SCHWAN INSTALLATION GUIDE For Schwan SC60 FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your Schwan system. 2 INFORMATION AND SAFETY

More information

Your Pressure Sewer System. A Homeowner s Guide

Your Pressure Sewer System. A Homeowner s Guide Your Pressure Sewer System A Homeowner s Guide Your Pressure Sewer System A Homeowner s Guide CONTENTS Using this manual 2 Why install a pressure sewer system? 2 What is a pressure sewer system? 3 What

More information

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware

More information

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL INTRODUCTION Congratulations on choosing the Poolrite S6000 mk2, S5000 mk2, S8000 mk1 or S9000 mk4 High Rate Media Filter fitted with the exclusive

More information

Cinnamon Kitchen Sink Tap

Cinnamon Kitchen Sink Tap Cinnamon Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS LX 300 Pool Bolero ND Pump Cleaner INSTALLATION AND OPERATING INSTRUCTIONS Melbourne: 03 8796 8600 Gold Coast: 07 5552

More information

Blueberry Kitchen Sink Tap

Blueberry Kitchen Sink Tap Blueberry Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s

More information

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden

More information

STERI-VAC CENTRAL SUCTION SYSTEM

STERI-VAC CENTRAL SUCTION SYSTEM STERI-VAC CENTRAL SUCTION SYSTEM INSTALLATION MANUAL This is a general installation manual for Steri-Vac Central Suction Systems. For detailed information see specific technical sheet. These are high-volume

More information

Web:

Web: P.O Box - 95466, United Arab Emirates Tel: +971 4 2637073, Mobile: +971 55 2191246, +971 52 864 1667 Email: info@sancouae.com, Web: It's about Peace of mind and a job done right, First time, Every time

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

Flue Installation Manual

Flue Installation Manual Flue Installation Manual Rinnai FFSS (Stainless Steel) flue systems Rinnai FFSS (Stainless Steel) coaxial flue system, suitable for use with the following Rinnai internal continuous flow water heater models:

More information

Monza Easyfit Kitchen Sink Mixer

Monza Easyfit Kitchen Sink Mixer Monza Easyfit Kitchen Sink Mixer Installation Instructions & User Guide Please keep these instructions for future reference Contents Thank you for choosing Bristan, the UK s leading taps and showers expert.

More information

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9 Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative

More information

Owners Instruction Manual

Owners Instruction Manual Owners Instruction Manual Ultra Clear WASTE WATER TREATMENT SYSTEMS Domestic Single Tank Systems Contents Page Foreword 1 Description & Function Primary Treatment Aerobic Treatment Sludge Return Surge

More information

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7. Zip Econoboil Installation and Operating Instructions 301042 Zip Econoboil 1.5 litre White 303042 Zip Econoboil 3.0 litre White 305042 Zip Econoboil 5.0 litre White 307042 Zip Econoboil 7.5 litre White

More information

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5. DS 5.600 English.... 5 Français... 11 Español... 17 CONSUMO DE ENERGIA 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.600 59634180 (04/12) 2 3 4 Dear Customer, Please read and comply

More information

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts Decade Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading taps

More information

Prohibitions on using

Prohibitions on using Prohibitions on using Chemicals, Enzymes, or Bacteria in Grease Traps and Interceptors CHEMICALS ENZYMES BACTERIA Chemicals: the use of chemicals to clean grease traps or interceptors is strictly prohibited

More information

Greenleaf 600 Macerator Toilet Waste Pump

Greenleaf 600 Macerator Toilet Waste Pump Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.

More information

ACO Building Services

ACO Building Services ACO Building Services Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Grease separators from ACO Building Services Areas

More information

Target Monobloc Kitchen Mixer Chrome

Target Monobloc Kitchen Mixer Chrome Target Monobloc Kitchen Mixer Chrome Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan,

More information

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation

More information

STEAM WALLPAPER STRIPPER MODEL HTW5

STEAM WALLPAPER STRIPPER MODEL HTW5 STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,

More information

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation Issue 4 Oct 2005 Panamatic Top loading Maxi & Optima 3 Installation Please Do handle the unit with care, to avoid scuffs and scratches during installation. Do not over-tighten plumbing or any other mechanical

More information

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water Installation and Operating Instructions Zip Hydroboil Filtered instant boiling water 01552 Zip Hydroboil 1.5 Litre White 01551 Zip Hydroboil 1.5 Litre Stainless Steel 03552 Zip Hydroboil 3 Litre White

More information

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 05 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed

More information

Keeping. Fats, Oils, and. Grease. Out of the Sewer

Keeping. Fats, Oils, and. Grease. Out of the Sewer Keeping Fats, Oils, and Grease Out of the Sewer Questions and Answers for Food Service Establishments regarding Fats, Oil, and Grease and Grease Removal Devices City of Paso Robles, Wastewater Division,

More information

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT GUARANTEE & AFTERCARE When installing or using tools, extra care must be taken to avoid damaging the finish or fitting. To maintain

More information

Installer manual GreenMaster-HP

Installer manual GreenMaster-HP Installer manual GreenMaster-HP Transport and installation Ventilation unit IHB EN 1747-2 8017172 2 GreenMaster-HP Transport and installation Introduction Here you can read about how best to handle the

More information

Beeline Monobloc Kitchen Mixer Tap

Beeline Monobloc Kitchen Mixer Tap Beeline Monobloc Kitchen Mixer Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the

More information

PROPOSED NEW BUILDING

PROPOSED NEW BUILDING HYDRAULIC DRAWINGS MATERIALS SERVICES TO BE CONSTRUCTED FROM MATERIAL AS LISTED BELOW UNLESS NOTED OTHER WISE SHOWN ON DRAWINGS. SERVICE MATERIAL REMARKS SEWER DRAINAGE upvc SOLVENT WELDED JOINTS SEWER

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

ACO Haustechnik. Installation and Operating Manual _01 As per: 03/2010

ACO Haustechnik. Installation and Operating Manual _01 As per: 03/2010 ACO Haustechnik Installation and Operating Manual 0150.15.14_01 As per: 03/2010 ACO Grease separator plants for free-standing installation and complete disposal according to DIN EN 1825 and DIN 4040-100

More information

SUBMERSIBLE WATER PUMP

SUBMERSIBLE WATER PUMP WHAT S IN THE BOX SUBMERSIBLE WATER PUMP 350W INSTRUCTION MANUAL SPECIFICATIONS Motor: 350W Max. Flow Rate: 7,000l/h Max. Head 5m Max. Immersion: 5m Min. Suction Depth 50mm Max Particle Size: Ø30mm Water

More information

Fat, oil and grease is known as FOG in the drainage industry.

Fat, oil and grease is known as FOG in the drainage industry. Fat, oil and grease is known as FOG in the drainage industry. Putting FOG down your drains can have serious consequences. It can damage your drains, cause costly blockages, and leave you open to prosecution

More information

GREEN LOO DRY COMPOSTING TOILET MANUAL. for the. GT 120 Family and GT 330

GREEN LOO DRY COMPOSTING TOILET MANUAL. for the. GT 120 Family and GT 330 GREEN LOO DRY COMPOSTING TOILET MANUAL for the GT 120 Family and GT 330 INSTALLATION PLANNING It's all in the planning! For proper operation of the toilet you should consider a number of issues during

More information

NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN

NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN NEUTRA grease separators for vege table and animal fat in compliance with EN 1825 and DIN 4040-100 Separating technology A problem that should not be underestimated: Fat in wastewater All vegetable and

More information

CLEAN WATER SUBMERSIBLE PUMP

CLEAN WATER SUBMERSIBLE PUMP WHAT S IN THE BOX CLEAN WATER SUBMERSIBLE PUMP 550W INSTRUCTION MANUAL SPECIFICATIONS Motor: 550W Max. Flow Rate: 15,500l/h Max. Head: 8.5m Max. Immersion: 7m Min. Suction Depth: 50mm (automatic) 5mm (manual)

More information

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens. 103592 Zip Econoboil 3.0 litre White HS503 105592 Zip Econoboil 5.0 litre White HS505

More information

PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.

PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP. PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP. GI SERIES GREASE TRAP INSTALLATION GUIDE Overview Atlantic Metalworks GI series grease traps are designed

More information

Specification, Installation and Operation Manual. Bain Marie. Models: W.BMA22, W.BMA23, W.BMA24, W.BMA25, W,BMA26, W.BMS11 & W.

Specification, Installation and Operation Manual. Bain Marie. Models: W.BMA22, W.BMA23, W.BMA24, W.BMA25, W,BMA26, W.BMS11 & W. Specification, Installation and Operation Manual Bain Marie Models: W.BMA22, W.BMA23, W.BMA24, W.BMA25, W,BMA26, W.BMS11 & W.BML21 A guide on the use, care and maintenance of your quality Woodson product

More information

DIRTY WATER SUBMERSIBLE PUMP

DIRTY WATER SUBMERSIBLE PUMP WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP 750W INSTRUCTION MANUAL SPECIFICATIONS Motor: 750W Max. Flow Rate: 15,000l/h Max. Head 8m Max. Immersion: 8m Min. Suction Depth 50mm Max Particle Size: Ø35mm

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

51AKS I S O OWNER S MANUAL

51AKS I S O OWNER S MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS

More information

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms. Installation Instructions Zip HydroTap Filtered Chilled drinking water for commercial kitchens and tea rooms. Affix Model Number Label Here 801525 801525 - Zip HydroTap Installation Instructions - Nov.

More information

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters 1 Heater kit contains : Heater, mounting bracket Fuel hose (3 meters), pump, a fuel tank connection to standard tanks (15, 22, 30 litres) Power supply

More information

CLEAN WATER SUBMERSIBLE WATER PUMP

CLEAN WATER SUBMERSIBLE WATER PUMP STANDARD EQUIPMENT CLEAN WATER SUBMERSIBLE WATER PUMP 400W INSTRUCTION MANUAL SPECIFICATIONS Motor: 400W Max. Flow Rate: 4,200l/h Max. Head: 11m Max. Immersion: 5m Min. Suction Depth: 50mm Max Particle

More information

Operating Instructions

Operating Instructions Operating Instructions ProtectoAutoclenz ProtectoAutoclenzTwin Weldability sif Peters House, The Orbital Centre Icknield Way, Letchworth Garden City Hertfordshire SG6 1ET Tel.: +44 (0) 845 862 2620 Fax:

More information

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT C US This manual must be left with owner and should be hung on or adjacent to the boilerfor reference. COMMON VENTING MODELS CHS-300 through CHS-399 INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS

More information

How To Size A Big Dipper Unit

How To Size A Big Dipper Unit Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size

More information

X62 Tap Range. Please keep these instructions for future reference

X62 Tap Range. Please keep these instructions for future reference X62 Tap Range This instruction booklet covers: X625205CP, X625215CP, X625255CP, X625265CP, X625122CP, X625126CP, X625135CP Please keep these instructions for future reference 02 For latest prices and delivery

More information

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages. Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water heater for beverages. Model No. Description Reg.No. Part No. HS503 Zip Econoboil 3.0 litre White EB003 103592 HS505

More information

Installation guide Sahara & Sahara Plus

Installation guide Sahara & Sahara Plus Installation guide Sahara & Sahara Plus Installation requirements. Components for Billi Sahara 310, 320, 360 & 3120 Models Before commencing installation, ensure you have identified the following. 1. Underbench

More information

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE: 0870 428 0075 CONTENTS Page 2 - Unpacking Page 3 - Heating system preparation and

More information

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

Owners Manual for the Rainmaster Water Recycling System

Owners Manual for the Rainmaster Water Recycling System Owners Manual for the Rainmaster Water Recycling System 22874 Manual.indd 1 4/8/05 8:45:05 AM Rain Master Water Recycling System Welcome! Thank you for purchasing a Rainmaster Water Recycling System. Your

More information

Manual / Handbuch Spare parts list / Ersatzteilliste

Manual / Handbuch Spare parts list / Ersatzteilliste Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a

More information

Wall Mounted BBQ GRHM & GRHL

Wall Mounted BBQ GRHM & GRHL Wall Mounted BBQ Rangehood GRHM & GRHL GRHM GRHL Gasmate is a registered trademark of: Sitro Group Australia Pty Ltd www.gasmate.com.au Aber Hamilton, N.Z. www.gasmate.co.nz Important: Retain these instructions

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by

More information

SCHWAN INSTALLATION GUIDE

SCHWAN INSTALLATION GUIDE SCHWAN INSTALLATION GUIDE For Schwan Versatap SC52E Instant Hot Cold Filtered Water FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your

More information