WIRING DIAGRAM for Connection Box for electric fan motor (JB-1)
|
|
- Garry Bruce
- 5 years ago
- Views:
Transcription
1
2
3 0
4 INTERNAL VIEW WIRING DIAGRAM for Connection Box for electric fan motor (JB-1) INCOMING SUPPLY 3ph/400V/50-60Hz (ALTERNATIVELY SUPPLY 3ph/230V/50-60Hz) WHITE GRAY R S T R S T R S T R S T R S T TK TK TK TK TK TK FAN MOTORS CONNECTION CONNECTION DIAGRAM R S T R S T R S T R S T R S T TK TK TK TK TK TK PE M M M M M FAN MOTOR 5 FAN MOTOR 4 FAN MOTOR 3 FAN MOTOR 2 FAN MOTOR 1
5 This page and next one show the connection box for connection of defrost and electric element drain line
6 INTERNAL VIEW MAXIMUM CONFIGURATION Connection diagram 12 elements Max 48 kw WIRING DIAGRAM L N L1 L2 L3 N L2 L3 L1L2L3 N L1 L2 L3 N PE L1 L2 L3 N INCOMING SUPPLY 3ph/400V/50-60Hz BY CUSTOMER L1 L2 L3 N INCOMING SUPPLY 3ph/400V/50-60Hz BY CUSTOMER L1 2 WIRES X 4 mmq L2 2 WIRES X 4 mmq L3 N 2 WIRES X 4 mmq 3 WIRES X 4 mmq RB (OPT.) RB - RESISTOR FOR ELECTRICAL DEFROST ON DRIP TRAY ONLY (OPTIONAL)
7 This page and next one show the connection box for connection of defrost and electric element drain line
8 INTERNAL VIEW MAXIMUM CONFIGURATION Connection diagram 21 elements Max 84 kw WIRING DIAGRAM L N L2 L3 L1 L2 L3 N L1 L2 L3 N L1 L2 L3 N PE L1 L2 L3 N INCOMING SUPPLY 3ph/400V/50-60Hz BY CUSTOMER L1 L2 L3 N INCOMING SUPPLY 3ph/400V/50-60Hz BY CUSTOMER RB (OPT.) L1 5 WIRES X 4 mmq L2 5 WIRES X 4 mmq L3 N 5 WIRES X 4 mmq 5 WIRES X 4 mmq RB - RESISTOR FOR ELECTRICAL DEFROST ON DRIP TRAY ONLY (OPTIONAL)
9 Valid for fan ring heater, drain line heating element and dip tray heating connections (OPTIONALS)
10 INTERNAL VIEW Supply V (3ph+N) by customer Alternatively supply 230V (3ph+N) by customer MAXIMUM CONFIGURATION Connection diagram 12 elements Max 48 kw INCOMING SUPPLY 3ph/ V/50-60Hz (Max: 24A) BY CUSTOMER (For max. power consumption sum total power of RH+RS+RB) N L1 L2 L3 PE WIRING DIAGRAM N L L2 L3 L1 PE L2 L3 PE L1 L2 L3 N INCOMING SUPPLY 3ph/400V/50-60Hz BY CUSTOMER RH RH RH RH RH RB RB RB RS NOTE : (1) THE CONNECTION DIAGRAM SHOWS THE MAXIMUM CONFIGURATION POSSIBLE (2) FOR POWER CONSUMPTION OF RESISTOR RB SEE SHEET N 13
11 0 Valid for local safety switch (optional)
12 NOTE : (1) Nom. current at Tair=20 C. Variations occur due to different voltage or Tair
13
14
15 MODEL Ø500 LOW ELECTRICAL DEFROST MODEL Ø560 ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST LOW ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST MODEL Ø630 LOW ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST ELECTRICAL DEFROST MODEL Ø800 ELECTRICAL DEFROST LOW ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST ELECTRICAL DEFROST
16
17
18 MODEL Ø500 LOW ELECTRICAL DEFROST MODEL Ø560 ELECTRICAL DEFROST LOW ELECTRICAL DEFROST ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST MODEL Ø630 LOW ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST MODEL Ø800 ELECTRICAL DEFROST LOW ELECTRICAL DEFROST DRIP TRAY ELECTRICAL DEFROST ELECTRICAL DEFROST
19 MODEL Ø500 WITH LEFT STANDARD CONNECTIONS WITH LEFT STANDARD CONNECTIONS ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FAN MOTOR - JB1 FRH AND ELECTRIC HEATERS(*) - JB3 FRH AND ELECTRIC HEATERS(*) - JB3 FAN MOTOR - JB1 ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FAN MOTOR - JB1 MODEL Ø630 ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FRH AND ELECTRIC HEATERS(*) - JB3 FRH AND ELECTRIC HEATERS(*) - JB3 MODEL Ø800 WITH RIGHT CONNECTIONS ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FRH AND ELECTRIC HEATERS(*) - JB3 FAN MOTOR - JB1 FRH AND ELECTRIC HEATERS(*) - JB3 ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FAN MOTOR - JB1 FAN MOTOR - JB1 WITH LEFT STANDARD CONNECTIONS WITH LEFT STANDARD CONNECTIONS WITH RIGHT CONNECTIONS FAN MOTOR JB1 MODEL Ø560 WITH RIGHT CONNECTIONS WITH RIGHT CONNECTIONS ELECTRIC HEATERS ON OPPOSITE SIDE - JB2 FRH AND ELECTRIC HEATERS(*) - JB3 FRH AND ELECTRIC HEATERS(*) - JB3 FAN MOTOR JB1
20
Evaporators and Coolers for COMMERCIAL USE. ALFACUBIC MODEL (DX, Brine and NH3) INSTRUCTIONS MANUAL IM EN
Evaporators and Coolers for COMMERCIAL USE ALFACUBIC MODEL (DX, Brine and NH3) INSTRUCTIONS MANUAL IM005 2006- TABLE OF CONTTS GERAL To the user... page 2 Safety... page 2 Equipment description... page
More informationPRICE LIST 2015 HEAT PUMPS
PRICE LIST 2015 HEAT PUMPS Propulsion Systems bvba Dooren 72 1785 Merchtem, Belgium BE 0478.198.221 Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.propulsionsystems.be info@propulsionsystems.be COMPACT 135
More informationCDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.
DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the
More informationFincoil FMP and FMPG. Air coolers and liquid circulated air coolers
Fincoil FMP and FMPG coolers and liquid circulated air coolers FMP air coolers and FMPG liquid circulated air coolers are designed for cold rooms where low profi le dual discharge air cooler is needed.
More informationCOTES ALL-ROUND THE C30 RANGE
COTES ALL-ROUND THE C30 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM COTES ALL-ROUND THE C30-RANGE IDEAL FOR USE IN Food industry processing facilities Cold stores Waterworks General humidity management
More informationPRICE LIST 2016 PR PULSION HEAT PUMPS SYSTEMS
PRICE LIST 2016 HEAT PUMPS Propulsion Systems bvba Dooren 72 1785 Merchtem, Belgium BE 0478.198.221 Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.propulsionsystems.be info@propulsionsystems.be COMPACT 135
More informationComplements and Accessories
Contents Chillers/heat pumps...196 GOD RX/C, Reversible heat pump...196 COO DX/COO DX Top, Cooling unit...211 Chiller, Celest +...218 lue ox, Chiller/eat pump...220 Air handling unit section...221 TCR
More informationAlfa Laval Optigo CC. Instruction manual. Product description Product labels Unpacking & lifting Installation Maintenance Spare parts
Alfa Laval Optigo CC Instruction manual Product description Product labels Unpacking & lifting Installation aintenance Spare parts ORIGINAL INSTRUCTIONS Index 1. Important information 1.1 Disclaimer...3
More informationRAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES
Digital touchpad control panel: 1. On-off switch 2. Reading of room temperature 3. Indicator for normal operation (green lamp) 4. Reading of RH value / setting of RH value 5. Indicator for full water container
More informationHIWARM COMPACT kw
Total heat recovery multi-purpose s HIWRM COMPCT Outdoor monobloc air-water with BLDC compressor HIWRM COMPCT - kw Total recovery and energy efficiency in every condition Total heat recovery multi-purpose
More informationMeiko USA 1349 Heil Quaker Blvd. Lavergne, TN
0 Meiko USA Heil Quaker Blvd. Lavergne, TN 0 00--0 FOR USE WITH THE FOLLOWING OPTIONS: Model Number : Voltage : Phase : DV0. 0 VAC 0 HZ ~ Internal Chemical Dosing Pumps Drain Water Tempering Kit Power
More informationBoiling water heater KA
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals > Catering services Product information 1 / 7 Product information boiling > 15 25 40 Part number
More informationApplications Damage service Building drying Water works Dry storing FEATURES
MOBILE DEHUMIDIFIER Function The is a robust, cost-effective and energy-efficient, reliable mobile dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the
More informationCDP 40 SWIMMING POOL DEHUMIDIFIER
CDP 40 SWIMMING POOL DEHUMIDIFIER Function The CDP 40 is an energy efficient and quiet pool dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier
More informationENVIRONMENT FRIENDLY CLIMATIC CHAMBER
ZERO OZONE DEPLETION POTENTIAL ODP NEGLECTIBLE GLOBAL WARMING POTENTIAL GWP ENVIRONMENT FRIENDLY CLIMATIC CHAMBER KK-50 DFA TK-50 CKA KK-730 DFA TK-730 CKA Environment friendly solution for temperature
More informationBoiling water heater HBE
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals Product information 1 / 6 Product information boiling > 6-003 6-005 6-007 Part number [case painted
More informationNew Generation KBF 240 series
Constant climate chambers New Generation 240 series The constant climate chamber is the expert for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationBottom Mount Refrigerator Technical Information
Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information
More informationGoedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers
Goedhart VNS Air coolers for agricultural applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VNS The Goedhart VNS range of ceiling mounted aircoolers are specially
More informationDue to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
Bottom Mount Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTIN All safety information
More informationBCP & BCM COMBI OVENS REPLACEMENT PARTS LIST
BCP & BCM COMBI OVENS REPLACEMENT PARTS LIST EFFECTIVE APRIL, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are not available.
More informationJBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0
Bottom Mount Refrigerator Technical Information JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0 Due to a possibility
More informationDue to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.
Bottom Mount Refrigerator Technical Information Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.! CAUTION
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationBlow through unit coolers LEX. Standard coolers for cooling & freezing rooms
Blow through unit coolers LEX Standard coolers for cooling & freezing rooms O `çåíéåíë pag. Model indication..................................2 Eurovent.......................................2 General
More informationS F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu
GB D S F IT 6" / 8"HES Quick Installation Guide franklinwater.eu Summary Page English 5-19 Deutsch 25-39 Svenska 44-60 French 63-81 Italian 84-101 GB 6" / 8"HES Quick Installation Guide franklinwater.eu
More informationin/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)
CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used
More informationCDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES
CDP 40T SWIMMING POOL DEHUMIDIFIER Function The CDP 40T is an energy efficient and quiet pool dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationCAUTION. No-Load Performance, Controls in Normal Position
Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*
More informationEEDEN technical data ERHQ AA
EEDEN08-70 technical data Altherma Outdoor units R-410A Altherma Outdoor units 34 1 Features 1 O u t d o o r u n i A l t h e r m a E R H Q 0 1 1-0 1 6 A A R - 4 1 0 A Cost effective alternative to a fossil
More informationAFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION
Bottom Mount Refrigerator Technical Information AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0! CAUTION Due to a possibility of personal injury or property damage, always contact an authorized technician
More informationColt CoolStream Adiabatic Cooling & Ventilation System
Colt CoolStream Adiabatic Cooling & Ventilation System Colt CoolStream Adiabatic Cooling & Ventilation System Colt coolstream Adiabatic cooling & ventilation system DESCRIPTION Colt CoolStream is a natural
More informationSubmittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating
GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating The High Efficiency AYF60-119 units are 2 module appliances; each AYF is
More informationSINGLE COMPACT DISC METALLIZATION TYPE SINGULUS III / 3
Revision Date: 10. March 1999 TECHNICAL SPECIFICATION SINGULUS III / 3 SPECIFICATION NO. 010696 PRODUCTION SYSTEM PREPARED FOR SINGLE COMPACT DISC METALLIZATION TYPE SINGULUS III / 3 SINGULUS TECHNOLOGIES
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationEnvironmental Chambers
Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm
More informationRoth fixed-value control set with high-efficiency pump
Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical
More informationCompact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.
INFO SLIM Compact Air cooler GASC Air coolers in a flat design with forced draught fans Optimal for commercial cooling HFCs, CO 2 0.6 14 kw Air coolers for small cold rooms The ideal solution for small
More informationRoom Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature
1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and
More informationCAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.
Bottom Mount Technical Information ABB1922FE* ABB1922FE*0, ABB1927DE* ABB1927DE*2, ABB2222FE* ABB2222FE*0, ABB2227DE* ABB2227DE*2, ABB222FE* ABB222FE*0, ABB227DE* ABB227DE*2, ABC2037DE* ABC2037DE*2, ABC2037DP
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationCAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%
Bottom Mount Refrigerator Technical Information JBC2088HT* JBC2088HT*1, JBL2088HES JBL2088HES1, JBR2088HES JBR2088HES1, JFC2089HE* JFC2089HE*1, JFC2089HP* JFC2089HP*1, JFC2089HT* JFC2089HT*1, KBFA20ERBL
More informationShrinking STCW 60 / STCW 80 Drying DU 60 / DU 80 Transporting CB 60 / CB 80
Shrink Units Shrinking STCW 60 / STCW 80 Drying DU 60 / DU 80 Transporting CB 60 / CB 80 Inline shrink equipment for large / industrial size operations A d v anc ed V acuum P ack a g ing S y s t ems Shrink
More informationModels Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.
Models Vallox 096 MC R Vallox 096 MC L Type 3721-1 Document D2609 Valid from 24.2.2017 Updated 12.2.201 MANUAL Manual Ventilation unit MAIN PART Extract air fan (behind the protective cover) upply air
More informationThe ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners
More informationMPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS
Air chillers and heat pumps MPI DC Outdoor monobloc unit with BLDC compressor MPI DC - 9 kw Large operating range and energy efficiency under every condition BLDC scroll compressor PLUS BLDC rotary compressor
More informationMain technical datas:
DCS - DCVS Dry Coolers Frigosystem, the patent holder for free cooling and dual free cooling in single frame, present the new generation line of DRY COOLERS, born to satisfy the request of cost saving.
More informationConstant climate chambers
Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationAlfa Laval Arctigo ID
Alfa Laval Arctigo ID Instruction manual Product description Product labels Unpacking & lifting Installation Maintenance Spare parts ORIGINAL INSTRUCTIONS Index 1. Important information 1.1 Disclaimer...3
More informationACE. HydroStream Model HC-100. Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...
AC E Air Cleaning Equipment Inc 303 N Main St Broadway NC 27505 800-962-0650 www.industrialairtreatment.com Evaporative Humidification (100 lbs/hr) Produces Already Humidified Air Information Specifications...
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationKMF Environmental test chamber for constant climate
SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The
More informationTILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018
Page 1 of 7 Publish Date May 29, 2018 FUNCTION Rotation detection at 45 in vertical position APPLICATIONS 1 Rotation Detection for kinds of monitor/device 2 Toys / Entertainment devices FEATURES 1 Suitable
More informationPlanning guide. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More information2 Gallon Water Boiler
USER S GUIDE 2 Gallon Water Boiler READ AND SAVE THESE INSTRUCTIONS NOTICE TO INSTALLER: Please leave this booklet with the machine. CONTENTS CL39...FS39... IS2...II20...II21...CI16............ES83.........
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationTITAN SYSTEM ENGINEERING DATA SHEET TITAN HXS
This document and specifications are the property of REsys and shall not be reproduced or disseminated other than for recipients use for internal evaluation of REsys prices and product specifications.
More informationMotor-driven condensing units MTE MTE R-410A
Motor-driven condensing units MTE Outdoor motor-driven condensing units MTE - 0 kw Efficiency and compactness for commercial air conditioning Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split
More informationAir cooler BC50 Blast freezer
Air cooler BC50 Blast freezer Cu/Al - R404A GEA Heat Exchangers Goedhart Goedhart Air Cooler Cu/Al BC50 Goedhart BC50 Goedhart BC50 blastfreezers The Goedhart BC50 blast freezers are a range of floor mounted
More informationModel CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor
Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor The BINDER CB series CO 2 incubator is the premium class among the CO 2 incubators. It is suitable for all sensitive
More informationSERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS Revision : A MXZ-A5/A7VA- MXZ-A0/A5VA- Please void OB77 E E has been added. has been added. OUTDOOR UNIT SERVICE MANUAL HFC utilized R0A No. OB77 REVISED EDITION-A
More informationWS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.
Technical sheet Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection TOUCHSCREEN DISPLAY - RADIO-CONTROLLED TIME AND DATE INDOOR/OUTDOOR TEMPERATURES AND HUMIDITIES - WEATHER
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationAir cooler VNS Agricultural
Air cooler VNS Agricultural Cu/Al - R404A GEA Heat Exchangers Goedhart Goedhart Air Cooler Cu/Al VNS Goedhart VNS The Goedhart VNS range of ceiling mounted aircoolers are specially designed for use in
More informationCOTES ALL-ROUND THE C35 RANGE
EPERTS IN HUMIDITY MANAGEMENT COTES.COM DEHUMIDIFICATION THE WAY YOU WANT IT C35 DEHUMIDIFIER IDEAL FOR USE IN > PHARMACEUTICAL PRODUCTION FACILITIES > FOOD INDUSTRY PROCESSING FACILITIES > COLD STORES/FREEZER
More informationAir Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses
NEW! REC Temovex Blue 4 Experts on indoor climate in low-energy houses REC Temovex Blue 4 Third generation of our Temovex units! - Dual counterflow heat exchangers with over 9% efficiency * - SFP < 1,
More informationConstant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:
Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationAir Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1
Air Conditioning Technical Data EEDEN-00 RZQSG-L(/8)V Outdoor Unit RZQSG-L(/8)V TABLE OF CONTENTS RZQSG-L(/8)V Features............................................................. 2 2 Specifications.......................................................
More informationInstallation Instructions
CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11
More informationAir Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C
Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................
More information1 of 9. A Craft Kitchen RUBINE WATER HEATER RSO-IAS8-35GX
A Craft Kitchen WATER HEATER SERIES INTELLIGENT AGENT (IA) PUMP DC (Inverter silent pump with 60% energy saving) COLOR SILVERED TITANIUM, CLASSIC GOLD, MODERN WHITE, METALLIC GREY SHOWER ACCESSORIES SHOWER
More informationHeating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT
Heating / Air Conditioning Energy Heat Recovery Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONENTAL COFORT Heating Air Conditioning ENVIRONENTAL
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationModel MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range
Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range The BINDER MKFT series environmental simulation chamber for low temperature
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationGAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND
GAS CONDENSING BOILERS RELIABILITY AND PEACE OF MIND THE DAIKIN GAS CONDENSING BOILERS: A NEW GENERATION OF HIGH-EFFICIENCY BOILERS FOR TOP COMFORT AND LOW COSTS The quality solution for reliability, flexibility
More informationSpare parts. Alfa Laval Arctigo IS - Industrial air coolers
Alfa Laval Arctigo IS - Industrial air coolers 2 3 4 5 6 7 8 9 10 1 Industrial air coolers Arctigo The listed items are available as spare parts for Alfa Laval Arctigo air coolers. 1 2 3 4 5 6 7 8 9 10
More informationEXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction
Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision
More informationAir Conditioning. Technical Data EEDEN RZQG-L8/7V1
Air Conditioning Technical Data EEDEN14-100 RZQG-L8/7V1 Outdoor Unit RZQG-L8/7V1 TABLE OF CONTENTS RZQG-L8/7V1 1 Features............................................................. 2 2 Specifications.......................................................
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationOil & Gas Case History
Unit Type: Air Handling Unit & Compressor Skid (AHU+CSV) Project Name: FGP LER Substation 51 Cooling Duty: No. 2 x 228 kw Site Location: Kazakhstan Year: 2017 End User: TengizChevrOil Manufacture of 2
More informationHIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS
Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose
More informationConstant climate chambers
Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the
More informationTruck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)
Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM (Rev. 0, 06/17) Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM
More informationTILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018
Item No RBS100600 Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018 FUNCTION 25 Tilt Detecting for 4 Directions in horizontal position APPLICATIONS 1 Wake up systems for power saving,
More informationCOTES ALL-ROUND THE C65 RANGE
COTES ALL-ROUND THE C65 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM COTES ALL-ROUND THE C65 RANGE IDEAL FOR USE IN Food industry processing Pharmaceutical production Cold stores/freezer facilities Waterworks
More informationShrinking STCW 60 / STCW 80 Drying DU 60 / DU 80 Transporting CB 60 / CB 80
Shrink Units Shrinking STCW 60 / STCW 80 Drying DU 60 / DU 80 Transporting CB 60 / CB 80 Inline Shrink Equipment for Large/Industrial Size Operations Shrink Units Visually appealing and in excellent form
More informationOperating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P
Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P with integrated pressure sensor - Art-No.: 30588 / mit eingebautem Drucksensor - Art-Nr.: 30588 GB DE Operating instructions DVC-P 2-13
More informationTumble dryer PT 5136 PT en - GB. Installation plan
Installation plan Tumble dryer PT 5136 PT 7136 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning
More informationKüba SG commercial
GEA Küba 42 Küba Blue Line : Specific advantages High performance air cooler for commercial applications with a large scope and complete capacity spectrum. Draw-through fans guide the air flow evenly through
More informationMPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.
Air chillers and heat pumps MPE Outdoor monobloc unit MPE - kw Efficiency under all operating conditions Rotary compressor PLUS Scroll compressor R-0A R-0A refrigerant Cooling only Cooling / Heating Monobloc
More informationAir Conditioners Technical Data
Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 CTXS-K Indoor Unit Wall mounted unit CTXS-K TABLE OF CONTENTS CTXS-K Features.............................................................
More informationPERTRONIC INDUSTRIES LTD F4-RMAX Installation Note
Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to
More informationNew TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system
New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,
More informationPARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001
EFFECTIVE: SEPTEMBER 1, 2001 ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 211-0044L-R / 212-0044R-L ADC-44 Conveyor Dishwasher 2
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More information