1 Alfa Laval Optigo CC Instruction manual Product description Product labels Unpacking & lifting Installation aintenance Spare parts ORIGINAL INSTRUCTIONS
2 Index 1. Important information 1.1 Disclaimer Intended use Where to find product information Product description Optigo CC 2.1 General information & application Standard configuration Options Code description Product labels Unpacking and lifting Installation 5.1 ounting dimensions ounting bracket Technical spaces Refrigerant connections Drain line Electrical connections Electric defrost capacities aintenance 6.1 Fan replacement Driptray & drain Side covers Coil heater element replacement Driptray heater element replacement Spare parts
3 1 Important information 1.1 Disclaimer This Instruction anual applies to all Alfa Laval Optigo CC air cooler products and is supplied in combination with the Alfa Laval Air Cooler Product anual AHE Both manuals must be carefully examined and instructions should be followed up at all times. Alfa Laval does not accept liability for any damage resulting from non-compliance to the instructions as given in the manuals and order-related documents. 1.2 Intended use Air coolers are partly completed machinery according to achine Directive 2006/42/EC and are intended for incorporation in cooling systems. Declarations of Incorporation are available on www. alfalaval.com. Air cooler units may not be put into operation until the conformity of the complete machine or cooling system has been declared according to the following standards and directives: Pressure Equipment Directive 2014/68/EU achine Directive 2006/42/EC Low Voltage Directive 2014/35/EU Electrical Equipment of achines IEC Electro agnetic Compatibility 2014/30/EU Any applicable local or national legislation 1.3 Where to find product information Detailed technical data for individual product models are available in order related documents, on the product sticker and in product data sheets. Comprehensive technical information for all Alfa Laval air heat exchanger products is available on-line on This includes: Product manuals Instruction manuals Product leaflets & brochures Product data sheets (selection software) Dimensional drawings Electrical wiring diagrams Certificates Optigo CC Alfa Laval offers world-wide service and support in over 55 countries. In case of any questions or uncertainty please contact your local Alfa Laval representative. Contact addresses are available at 3
4 2 Product description Optigo CC 2.1 General information and application Optigo CC are commercial single discharge unit coolers for general application in small to mediumsized cooling, freezing and working rooms. Coolers are available in draw-through (CC) and blowthrough design (CCB). A wide range of models make them especially suitable for refrigerated working, processing and storage rooms. Dedicated ranges for H(C)FC refrigerants (E), brine (W) and CO2 (X). Optigo CC coolers are available from stock. Suitable for all HFC DX (E), CO2 DX (X) and brine refrigerants (W). Room temperatures +10 to -30 C. Capacity range 1 up to 55 kw (SC2). Air volumes 770 up to m3/h. odel Refrigerant Design pressure Test pressure CC(B) E HFC 40 bar 57 bar CC(B) X CO2 80 bar 114 bar CC(B) W Brine 10 bar 14.3 bar 2.2 Standard configuration Internally grooved Cu tubes and aluminium fins, smooth tubing for brine applications and dedicated thicker tubes for CO 2 application. Tube pitch is staggered. All HFC DX models fitted with a T-connection to improve the refrigerant distribution and for hotgas defrost in coil. Optigo CC coolers are available with 1 to 4 fans fitted with AC or EC fan motors in two fan speed executions (noise levels) H/L. Fan diameters 250, 300, 350, 400 or 500 mm drawing or blowing through the coil. Integrated thermo contacts (Clixon) standard for 3-phase AC motors. All single phase motors protected by an integrated internal overload switch. Electronically integrated overload protection for EC fan motors. All casing parts made of durable sheet metal, epoxy coated RAL Top plate corrosion resistant agnelis. All models fitted with hinged side panels and aluminium drip tray. Drip tray is adjustable for perfect leveling. Removable internal drip tray for inspection & cleaning. Hinged side panels and driptray, drain(s) 1½" BSP external Fitted with schräder valve on the suction connection for testing purposes. Sufficient room for fitting the expansion valve inside. Stickers indicate fan direction and refrigerant in/out. Optigo CC(B) 250/300/350 models are delivered in wood-reinforced cardboard boxes, CC(B) 400/500 models in wooden crates. All packings suitable for safe stacking. 4
5 2.3 Options Electric defrost systems. For cold rooms with room temperatures below 4 C and where frost build-up is likely, the application of a defrosting system is advised. Electric defrost for Optigo CC consists of stainless steel heater elements. The defrost elements are connected to separate terminals in the terminal box. Available defrost systems are: - Electric defrost in coil (standard E1, heavy E2) - Electric defrost in drip tray (HD) - Hotgas defrost in drip tray (HG) - Electric defrost in driptray & hotgas in coil Driptray insulation 12 mm + cladding (IS) Shut-up sock (S) Airsock adapter ring (SR) Available for CC400 and CC500 draw-through models only. Coil protection - Pre-coated aluminium fins (EP) - Cataphoresis treatment (CA) Stainless steel 304 casing and frame (SSC) Fan ring heater (FRH) Re-heating coil (RH) Switch on/off (SW) All fan motors wired to central connection box (CB) 2.4 Code description CC B E H E A S 230V BO SS E - EP 4.0 CU HD Commercial unit cooler 2 Air direction (default=draw through, B=blow through) 3 Refrigerant system (E = H(C)FC DX, X=CO2, W=brine) 4 Fan speed (H = high; L = low) 5 Fan motor type (empty=ac, E=EC fan) 6 Fan Ø (25=250, 30=300 [CCB only], 35=350, 40=400, 50=500 mm) 7 Number of fans (1 to 4) 8 CC version 9 Tube rows code (A, B, C) 10 No. of phases (S= 1 phase, T= 3 phases) 11 otor voltage 12 Packing (BO=box, CR=crate) 13 Casing material (PC=powder coated, SS= stainless steel) 14 Defrost system (A= air defrost, E= electric defrost, HG= hotgas, HG+E= hotgas + electic defrost in driptray) 15 Coil protection (EP= epoxy coated aluminium, CA=cataphoresis) 16 Fin spacing (3.3, 4, 5.5, 6, 7, 8, 10 or 11 mm) 17 Tube material (CU=copper) 18 Options 5
6 3 Product labels Product label anufacturer: Year: Alfa Laval Krakow Sp. z.o.o 2015 odel: CCEH502.1BD 400V CR PCE CA 5.5 CU Item ID: Serial no. AP O Unit Net Weight: 190 Kg ±5% Sn EXAPLE otorfan data: Vn: 3~400V f: 50 Hz odel Item ID Serial no..o. Unit Net Weight Code description (paragraph 2.4) To be communicated when ordering spare parts as they identify the unit. Order number Check before any lifting operation to ensure that proper lifting tools are used. WARNING READ INSTRUCTION ANUAL BEFORE INSTALLATIONS ORATIONS AND AINTENANCE TO AVOID INJURIES OR DAAGE Service enquiries 2. Product label - coil anufacturer: Year: Alfa Laval Krakow Sp. z.o.o 2015 odel:.o CCEH502.1BD 400V CR PCE CA 5.5 CU Item ID: Serial no. AP Sn Coil D data: I ax DN: 38 mm Fluid Group 2 Coil Ts: +125/-60 C Ps: 40 bar Pt: 57 bar Test Date: EXAPLE WARNING READ INSTRUCTION ANUAL BEFORE INSTALLATIONS ORATIONS AND AINTENANCE TO AVOID INJURIES OR DAAGE Service enquiries odel Item ID Serial no. ax DN Fluid Group Coil Ts Ps Pt Test date Code description (paragraph 2.4) To be communicated when ordering spare parts as they identify the unit. aximum diameter of the distributor tube According to D Range of operating temperatures for the coil Design pressure Test pressure Date on which the coil has been pressure tested in the factory 6
7 5.307 ATTENZIONE! CIRCUITO FRIGORIFERO PRECARICATO CON AZOTO WARNING! PRECHARGED REFRIGERANT CIRCUIT WITH NITROGEN ACHTUNG! VERLADTER KÄLTEITTELKREISLAUF IT STICKSTOFF ATTENTION! CIRCUIT FRIGORIFIQUE PRE-CHARGE AVEC AZOTE BHИМАНИЕ! СИСТЕМА ЗАПРАВЛНА АЗОТОМ 3. Nitrogen precharge warning Units are delivered from the manufacturer with an overpressure. Check pressure on the Schrader valve. With unpressurised unit: Immediate report to manufacturer and note on bill of delivery. ATTACCO GAS CALDO HOT GAS CONNECTION HEISSGASLEITUNG RACCORDEENT GAZ Cod Hotgas connection Connection for hotgas defrost (optional). ATTACCO LIQUIDO LIQUID CONNECTION FLÜSSIGKEITSLEITUNG RACCORDEENT LIQUIDE Cod Liquid connection Refrigerant liquid connection. 6. Fan motor Spare part item number 7. Electrical warning Electrically powered component. Switch off power supply before any maintenance or installation operation 8. Fan direction Sticker indicates fan rotation direction PARTI INTERNE IN OVIENTO A COANDO AUTOATICO. TOGLIERE TENSIONE PRIA DI TOCCARE AUTOATIC CONTROL EANS OVING INTERNAL PARTS. SWITCH OFF POWER BEFORE TOUCHING SCHALTUNG AUF AUTOATIK, INTERNE BAUTEILE IN BETRIEB. VOR ARBEITSBEGINN SPANNUNG UNTERBRECHEN ÉLÉENTS INTERNES A DÉARRAGE AUTOATIQUE. COUR L ALIENTATION ÉLECTRIQUE AVANT INTERVENTION Cod oving parts Warning: moving parts. Switch off power supply before any maintenance or installation activities. 10. Eurovent Product included in the Eurvent Certify All program. 7
8 4 Unpacking and lifting Always follow guidelines and instructions as given in the air cooler product manual AHE Optigo CC air coolers are delivered on a wooden pallet, either covered with a cardboard box or a wooden crate. Handling and positioning can take place manually (smaller models) or with use of a forklift. When more than one cooler units are delivered in a single shipment, packed air coolers may be stacked during transportation. Respect the maximum number of stacked air cooler units. max. units floor stacking : : : 2 max. 2 In order to avoid damage to the air cooler or falling of the unit, ensure that the lifting forks fully cover the support pallet. A CC 250/300/350 odels 250/300/350 must be turned before mounting. Place the unit on the ground and remove the cardboard box or top crate. Remove fixing screws to lower support pallet. anually turn the air cooler into mounting position on a second wooden pallet. Use adequate protective material to prevent the driptray from damaging. The cooler is now ready to be lifted into mounting position. 8
9 CC400/500 odels 400/500 are supplied in mounting postion. Place the unit on the ground and loosen the fixing materials from the top crate. Remove top crate and driptray (supplied unmounted). Remove fixing screws to lower support pallet. For CC400/500, turn mounting brackets into correct position and secure with supplied fixing materials. The cooler is now ready to be lifted into mounting position. Lift the unit into mounting position and secure following instructions given in chapter 5 Installation. After having fixed the cooler to the ceiling, place driptray on its hinges (CC400/500 only). Use supplied fixing materials to fasten the driptray. 9
10 5 Installation Always follow guidelines and instructions as given in the air cooler product manual AHE ounting dimensions cooler model Shipping Dimensions ± 5 mm volume C H L A B m 3 Draw-through CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC CC Blow-through CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB CCB L L A ( B ) ( B ) H C C Ø1" Ø1" A ( B ) ( B ) H G ext. 10 CC250/300/ CC400/ CCB250/300/ CCB400/500 Detailed drawings showing all required mounting and refrigerant connection dimensions are available for download on Dimensional drawings 10
11 5.2 ounting bracket CC250/300/350 CC400/500 Use extra wide washers (ISO 7093) when mounting the unit to the ceiling. extra wide washers ISO Technical spaces Respect the minimum wall distance on suction side. D H coil H coil D Respect the minimum space for defrost heater extraction and replacement. D D L L 11
12 5.4 Refrigerant connections Never bend the air cooler refrigerant connection tubes. 5.5 Drain line The drain line diameter must be at least the size of the driptray drain diameter and should be laid with an adequate slope. For room temperatures below 0 C drain line insulation and defrosting are required. A syphon must be installed on the drain line, outside the cold room Tighten drain connection by hand only. 12
13 5.6 Electrical installation Fully detailed electrical connection diagrams are available for download on The following data determine which connection diagram is to be selected and respected for electrical installation: Cooler model indication Fan motor type Electrical options Electrical connections Please find below the electrical connection diagrams for standard configurations. When in doubt always contact your local supplier or Alfa Laval representative for assistance. Electrical connections 1-phase AC fan motors 1 fan 2 fans L N L N L N L N L N
14 Electrical connections 1-phase AC fan motors 3 fans L N L N L N L N L N fans L N L N L N L N
15 Electrical connections 3-phase AC fan motors 1 fan U V W TK TK WH PK U1 V1 W1 TK TK -1 3 ~ TK1 2 fans U V W TK1 TK2 TK3 WH PK WH PK U1 V1 W1 TK TK U1 V1 W1 TK TK -1 3 ~ TK1-2 3 ~ TK2 15
16 3 fans U V W TK1 TK2 TK3 TK4 WH PK WH PK WH PK U1 V1 W1 TK TK U1 V1 W1 TK TK U1 V1 W1 TK TK -1 3 ~ TK1-2 3 ~ TK2-3 3 ~ TK3 U V W TK1 TK2 TK3 TK4 TK5 4 fans WH PK WH PK WH PK WH PK U1 V1 W1 TK TK U1 V1 W1 TK TK U1 V1 W1 TK TK U1 V1 W1 TK TK -1 3 ~ TK1-2 3 ~ TK2-3 3 ~ TK3-4 3 ~ TK4 16
17 Electrical connection for 1-4 EC fan motors 1-phase (2-speed, CC250 only) L SN N -1 SN N -2 SN N -3 SN N -4 L L L L Fan speed selection High/Low SN N Open the fan motor connection box. You will find the electric wiring diagram inside. High speed connection - Connect blue wire (N) to neutral. - Connect black wire (L) to power supply. black blue black brown Low speed connection - Connect blue wire to neutral (N) and black wire to power supply (L). - Open the orange clamps from the blue and brown wires. - Create a jumper connection between the brown (SN) and the blue (N) wires. This extra piece of cable is not supplied with the unit. blue 17
18 Electrical connection for 1-4 EC fan motors 1-phase with 0-10V speed regulation Signal box L N 10V SN 0V Jumper connection for fixed high fan speed. Replace with 6.7V resistance for low fan speed or external signal for rpm modulation. BU L N +10V 0-10V GND L N +10V 0-10V GND L N +10V 0-10V GND L N +10V 0-10V GND Blue: GND - Control interface Yellow: Control input 0-10V or PW Red: Voltage output +10V (1.1 ma) White: Tach output Black: 230 VAC, Hz Blue: Neutral Green/Yellow: Protective earth Jumper Resistance kit Axial-lead resistor 0.25W 3.9 kω ±5% 6.8 kω ±5% 10V SN 0V High speed setting The High speed setting provides the maximum fan speed according to datasheet. This is achieved when a jumper connects the +10 V output of the fan motor to the inlet signal (see electrical scheme). If continuous rpm modulation is needed, the jumper should be removed and replaced by an external signal (between 0 and 10 V max). The jumper connection can be made in the connection box or inside each fan motor s black box. Low speed setting The Low speed setting provides the reduced fan speed according to datasheet. This is achieved with a resistance kit reducing the steering signal from 10 V to 6.7 V. The fan will operate at a fixed rpm value. If continuous rpm modulation is needed, the resistance kit should be removed and replaced by an external signal (between 0 and 6.7 V max). This resistance kit is located inside the connection box (if selected) or inside each fan motor s black box. 18
19 Electrical connection for 1-4 EC fan motor 3-phase with 0-10V speed regulation L1 L2 L3 10V SN 0V Jumper connection for fixed high fan speed. Replace with 6.7V resistance for low fan speed or external signal for rpm modulation. Signal box L1 L2 L3 +10V 0-10V GND L1 L2 L3 +10V 0-10V GND L1 L2 L3 +10V 0-10V GND L1 L2 L3 +10V 0-10V GND Control Control Control Control For High/Low fan speed setting and fan speed modulation follow the same procedure as given for the 1-phase fan motors on page 18. Electrical connection for electric defrost CC400 & CC500 U V W N -R1 -R4 -R7 -R10 -R2 -R5 -R8 -R11 -R3 -R6 -R9 -R12 19
20 Electrical connection for electric defrost CC250 & CC350 N L N L Incoming supply 230V - 50Hz 1phase -R7 -R10 -R8 -R11 -R9 -R12 N L1 L2 L3 N L1 L2 L3 Incoming supply 400V - 50Hz 3phase+N -R1 -R4 -R2 -R5 -R3 -R6 20
21 5.7 Electric defrost capacities Draw-through CC odel Coil defrost Driptray defrost Optigo CC Tube rows heater elements no. power per heater W total power W heater elements no. total power W no. std heavy std heavy std heavy std heavy 251.1A B C A B C A B C A B A B C A B C A B C A B A B C A B C A B C A B C A B C A B C B C B C
22 Blow-through CCB odel Coil defrost Driptray defrost Optigo CCB Tube rows heater elements no. power per heater W total power W heater elements no. total power W no. std heavy std heavy std heavy std heavy 251A B C A B C A B C A B A B C A B C A B C A B A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C A B C
23 6 aintenance Always follow guidelines and instructions as given in the air cooler product manual AHE Fan replacement Always disconnect power supply before performing any maintenance activities on fans and fan motors. Unscrew fixing bolts and remove old fan. ount new fan in identical position. Cable glands must be positioned downwards. Use an anti-corrosion compound when remounting the fixing bolts. Restore electric connection when the new fan has been mounted. 6.2 Driptray & drain The driptray can be opened for inspection, cleaning and maintenance purposes. Always disconnect drain line before opening the driptray. To open tray, first loosen and remove fixing bolts and then lower driptray. Respect the maximum opening angle (90 ) to avoid damage to the driptray hinges. 6.3 Side covers Hinged side covers can be opened for inspection, cleaning and maintenance purposes. To open side covers, loosen fixing bolts. 23
24 6.4 Coil heater element replacement Always disconnect power supply before handling heater elements. To remove coil heater elements, open side covers on both sides. Disconnect heater element from connection box. On the opposite cooler side, remove fixing screws and extract element from coil. ount new element in reverse order. Restore electrical connections and close side covers. 6.5 Driptray heater element replacement Always disconnect power supply before handling heater elements. To remove driptray heater elements, open side cover on connection box side and disconnect heater element. Open drip tray. Disconnect heater element and remove element from bottom plate while slightly bending open the fixing clips. ount new element in reverse order. Close drip tray and restore electrical connections. Close side cover. Bend open clips 24
25 7 Spare parts Spare parts CC Article no. Spare parts CCB Article no. 1 AC fan motors 230/50/1 ø 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1 AC fan motors /50/3 ø 3ph/230D-400YV/50-60Hz H SP 3ph/230D-400YV/50-60Hz H SP 3ph/400V/50-60Hz H SP 3ph/400V/50-60Hz L SP 3ph/400V/50-60Hz H SP 3ph/400V/50-60Hz L SP 1 EC fan motors 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 3ph/ V/50-60Hz H SP 3ph/ V/50-60Hz L SP 1 AC fan motors 230/50/1 ø 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1ph/230V/50-60Hz H SP 1ph/230V/50-60Hz L SP 1 AC fan motors /50/3 ø 3ph/230D-400YV/50-60Hz H SP 3ph/400V/50-60Hz L SP 3ph/230D-400YV/50-60Hz H SP 3ph/400V/50-60Hz H SP 3ph/400V/50-60Hz H SP 3ph/400V/50-60Hz L SP 1 EC fan motors 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 1ph/230V/50-60Hz H/L SP 3ph/ V/50-60Hz H/L SP 25
26 Spare parts Optigo CC Article no. Spare parts Optigo CCB Article no. 2 Electric defrost heaters (coil & drip tray heater identical) Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP Defrost heater CC SP 2 Electric defrost kits (heaters, conn. box & fixing materials) KIT defrost heaters CC251AB SP KIT defrost heaters CC251C SP KIT defrost heaters CC252AB SP KIT defrost heaters CC252C SP KIT defrost heaters CC253AB SP KIT defrost heaters CC253C SP KIT defrost heaters CC254AB SP KIT defrost heaters CC351AB SP KIT defrost heaters CC351C SP KIT defrost heaters CC352AB SP KIT defrost heaters CC352C SP KIT defrost heaters CC353AB SP KIT defrost heaters CC353C SP KIT defrost heaters CC354AB SP KIT defrost heaters CC354C SP KIT defrost heaters CC401AB SP KIT defrost heaters CC401C SP KIT defrost heaters CC402AB SP KIT defrost heaters CC402C SP KIT defrost heaters CC403AB SP KIT defrost heaters CC403C SP KIT defrost heaters CC404AB SP KIT defrost heaters CC404C SP KIT defrost heaters CC501AB SP KIT defrost heaters CC501C SP KIT defrost heaters CC502AB SP KIT defrost heaters CC502C SP KIT defrost heaters CC503AB SP KIT defrost heaters CC503C SP KIT defrost heaters CC504AB SP KIT defrost heaters CC504C SP 2 Electric defrost heaters (coil & drip tray heater identical) Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB Defrost heater CCB501 Defrost heater CCB502 Defrost heater CCB503 Defrost heater CCB SP SP SP SP SP SP SP SP SP SP SP SP 2 Electric defrost kits (heaters, conn. box & fixing materials) KIT defrost heaters CCB251AB KIT defrost heaters CCB251C KIT defrost heaters CCB252AB KIT defrost heaters CCB252C KIT defrost heaters CCB253AB KIT defrost heaters CCB253C KIT defrost heaters CCB254AB KIT defrost heaters CCB301AB KIT defrost heaters CCB301C KIT defrost heaters CCB302AB KIT defrost heaters CCB302C KIT defrost heaters CCB303AB KIT defrost heaters CCB303C KIT defrost heaters CCB304AB KIT defrost heaters CCB304C KIT defrost heaters CCB351AB KIT defrost heaters CCB351C KIT defrost heaters CCB352AB KIT defrost heaters CCB352C KIT defrost heaters CCB353AB KIT defrost heaters CCB353C KIT defrost heaters CCB354AB KIT defrost heaters CCB354C KIT defrost heaters CCB401AB KIT defrost heaters CCB401C KIT defrost heaters CCB402AB KIT defrost heaters CCB402C KIT defrost heaters CCB403AB KIT defrost heaters CCB403C KIT defrost heaters CCB404AB KIT defrost heaters CCB404C KIT defrost heaters CCB501AB KIT defrost heaters CCB501C KIT defrost heaters CCB502AB KIT defrost heaters CCB502C KIT defrost heaters CCB503AB KIT defrost heaters CCB503C KIT defrost heaters CCB504AB KIT defrost heaters CCB504C SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP 26
27 Spare parts Optigo CC(B) Article no. Spare parts Optigo CC(B) Article no. 3 Fan ring heaters Fan ring heater P300W - CC(B)250 Fan ring htr P300W - CC (B) Fan ring heater P350W - CC(B)400 Fan ring heater P450W - CC(B)500 Heater support (4 per heater ring) SP SP SP SP SP 3 Fan ring heater kits (heaters, connection box & fixing materials) KIT fan ring heater SP KIT fan ring heater SP KIT fan ring heater SP KIT fan ring heater SP KIT fan ring heater 301 KIT fan ring heater 302 KIT fan ring heater 303 KIT fan ring heater 304 KIT fan ring heater 351 KIT fan ring heater 352 KIT fan ring heater 353 KIT fan ring heater 354 KIT fan ring heater 401 KIT fan ring heater 402 KIT fan ring heater 403 KIT fan ring heater 404 KIT fan ring heater 501 KIT fan ring heater 502 KIT fan ring heater 503 KIT fan ring heater SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP SP 4 Drip trays CC Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP Drip tray CC SP 4 Drip trays CCB Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP Drip tray CCB SP 5 Air streamer (draw-through models only) Air streamer for all CC500 models SP Spare parts can be selected and ordered in the online ebusiness tool Alfa Laval Anytime. If required please contact your local Alfa Laval Representative for assistance. Alfa Laval Anytime 27
28
Alfa Laval Arctigo ID
Alfa Laval Arctigo ID Instruction manual Product description Product labels Unpacking & lifting Installation Maintenance Spare parts ORIGINAL INSTRUCTIONS Index 1. Important information 1.1 Disclaimer...3
More informationAlfa Laval Arctigo IS
Alfa Laval Arctigo IS Instruction manual Product description Product labels Unpacking & lifting Installation Maintenance Spare parts ORIGINAL INSTRUCTIONS Index 1. Important information 1.1 Disclaimer...3
More informationSpare parts. Alfa Laval Arctigo IS - Industrial air coolers
Alfa Laval Arctigo IS - Industrial air coolers 2 3 4 5 6 7 8 9 10 1 Industrial air coolers Arctigo The listed items are available as spare parts for Alfa Laval Arctigo air coolers. 1 2 3 4 5 6 7 8 9 10
More informationAntarctic-Unit Cooler/Air Cooler
6- Installation, Operating & Maintenance Instructions Declaration by the Manufacturer, Annex II B As defined by the EC Machinery Directive (MD) 98/7/EC, the Low Voltage Directive (LVD) 006/95/EC and the
More informationBlow through unit coolers LEX. Standard coolers for cooling & freezing rooms
Blow through unit coolers LEX Standard coolers for cooling & freezing rooms O `çåíéåíë pag. Model indication..................................2 Eurovent.......................................2 General
More informationFincoil FMP and FMPG. Air coolers and liquid circulated air coolers
Fincoil FMP and FMPG coolers and liquid circulated air coolers FMP air coolers and FMPG liquid circulated air coolers are designed for cold rooms where low profi le dual discharge air cooler is needed.
More informationCompact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.
INFO SLIM Compact Air cooler GASC Air coolers in a flat design with forced draught fans Optimal for commercial cooling HFCs, CO 2 0.6 14 kw Air coolers for small cold rooms The ideal solution for small
More informationWIRING DIAGRAM for Connection Box for electric fan motor (JB-1)
0 INTERNAL VIEW WIRING DIAGRAM for Connection Box for electric fan motor (JB-1) INCOMING SUPPLY 3ph/400V/50-60Hz (ALTERNATIVELY SUPPLY 3ph/230V/50-60Hz) WHITE GRAY R S T R S T R S T R S T R S T TK TK TK
More informationNew Industrial Dual Flow Unit Coolers
New Industrial Dual Flow Unit Coolers One single smart platform offering a wide range of solutions 01 Applications Thanks to a considerable air flow and an optimal air distribution, the new Dual Flow Units
More informationGüntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw
GHN Güntner Info Vario Cubic for all refrigerants 4 240 kw Variable aircooler for industrial refrigerationw Variable aircoolers for manifold applications Material combinations for any application! The
More informationCompact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw
INFO CUBIC Compact Air cooler GSF Highly efficient compact air cooler Optimal for commercial refrigeration HFCs 1 55 kw Everything an air cooler requires The universal solution for commercial refrigeration!
More informationAir cooler BC50 Blast freezer
Air cooler BC50 Blast freezer Cu/Al - R404A GEA Heat Exchangers Goedhart Goedhart Air Cooler Cu/Al BC50 Goedhart BC50 Goedhart BC50 blastfreezers The Goedhart BC50 blast freezers are a range of floor mounted
More informationAir product news. Mid year Refrigeration
Air product news Mid year 2017 This newsletter is a sum up of what's new in this first half of 2017 for Alfa Laval air heat exchangers. News are organized by topic and product. 1 Refrigeration 1.1 Arctigo
More informationGoedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers
Goedhart VNS Air coolers for agricultural applications Cu/Al R404A - CO 2 engineering for a better world GEA Heat Exchangers Goedhart VNS The Goedhart VNS range of ceiling mounted aircoolers are specially
More informationThe ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners
More informationEngineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle
Engineered efficiency - no matter where or what KMe Coolers Fresh ideas from Searle GEA Searle GEA Searle - Commercial Air Coolers GEA Searle s wide range of commercial unit coolers guarantee the continued
More informationGHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.
GHF CXGHF GGHF HFC CO 2 Glycol Güntner Info High efficiency wall/ceiling-mounted air cooler 0.5 80 kw The all-in-one solution for commercial refrigeration! A well-thought-through solution for all commercial
More informationInstructions OP-LPHM & OP-MPHM OP-LPHM & OP-MPHM & OP-MPUM & OP-MPGM034
OP-PH018-026 & OP-PH007-010-012-015-018 OP-PH048-068 & OP-PH026-034 & OP-P034-046 & OP-PG034 1 FRCC.EI.019.A2. Danfoss Commercial Compressors 06/12 OP-PH096-136 & OP-P068-080-107 OP-PH215-271 & OP-P125-162
More informationMain technical datas:
DCS - DCVS Dry Coolers Frigosystem, the patent holder for free cooling and dual free cooling in single frame, present the new generation line of DRY COOLERS, born to satisfy the request of cost saving.
More informationTEC Coolers. GEA Heat Exchangers. GEA Searle
TEC Coolers GEA Heat Exchangers GEA Searle Quality and Performance making the difference Quality and Performance Eurovent Certification All applicable products are certified under the Eurovent CERTIFYALLprogram,
More informationEvaporators and Coolers for COMMERCIAL USE. ALFACUBIC MODEL (DX, Brine and NH3) INSTRUCTIONS MANUAL IM EN
Evaporators and Coolers for COMMERCIAL USE ALFACUBIC MODEL (DX, Brine and NH3) INSTRUCTIONS MANUAL IM005 2006- TABLE OF CONTTS GERAL To the user... page 2 Safety... page 2 Equipment description... page
More informationAir cooler VNS Agricultural
Air cooler VNS Agricultural Cu/Al - R404A GEA Heat Exchangers Goedhart Goedhart Air Cooler Cu/Al VNS Goedhart VNS The Goedhart VNS range of ceiling mounted aircoolers are specially designed for use in
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationInstallation and maintenance instructions for cabin units type vertical IDAC (V50)
GB Installation and maintenance instructions for cabin units type vertical IDAC (V50). Application. Bundled parts. Handling. Marking. Weight. Transport. Storage 5. Installation 5. Mounting 5. Water trap
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article
More informationInnovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)
Innovative Engineering Catalogue Evaporators EKL1. Extra low temperature applications (60 Hz) Heat Exchangers www.eka-kool.com Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms
More informationPR / MP I Laboratory / Medicine
Technology for Life Medical SYSTEMS Technology for Life PR / MP I Laboratory / Medicine / Pharmaceutical Refrigerators (with glass door) +5 C +4 C 292.9707.80 02/2013 BIOMEDICAL REFRIGERATION Innovative
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationDeep Freezers. Freezers. Biomedical Refrigeration I FR / MF
Deep Freezers and Plasma Storage Freezers Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu Deep Freezers
More informationKüba SG commercial
GEA Küba 42 Küba Blue Line : Specific advantages High performance air cooler for commercial applications with a large scope and complete capacity spectrum. Draw-through fans guide the air flow evenly through
More informationDEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE
TECHNOLOGY FOR LIFE DEEP FREEZERS AND PLASMA STORAGE FREEZERS Biomedical Refrigeration I FR / MF Low-temperature storage of plasma and other blood products at 41 C/ 35 C According to DIN 58375 www.dometic.lu
More informationRoof top SPACE RPC 315Z R407C MA00
Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,
More informationEvaporators 60HZ version
Innovative Engineering Catalogue Evaporators 60HZ version Heat Exchangers Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms Humidity controled cold rooms Air conditioning Refrigerated
More informationTECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE
GB TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE 5 kw - 213 kw TABLE OF CONTENTS 1 The series...4 2 Constructive features...4 3 Layout of components...5 4 Models and configurations...13 5 Technical
More informationTransformer oil coolers BETA & CETA
2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More information1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationAP-EH500-L/RQA9837. Installation Guide
AP-EH500-L/RQA9837 Duct Mounted Burst Fire Heater The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Duct Mounted Burst Fire Heater This Burst Fire Heater should only be used as a supplementary
More informationBrazed heat exchangers
HYGIENIC EQUIPMENT FOR FOOD & LIFE SCIENCES Brazed heat exchangers A product catalogue for refrigeration Refrigeration applications The brazed plate heat exchanger (BHE) is a well-established component
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More information30RH B Nominal cooling capacity kw Nominal heating capacity kw
Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.
More informationDirections for use. CPS/XPS - Condensor / Dry cooler
61221 Directions for use 1 2 Declaration by the Manufacturer, Annex II B As defined by the EC Machinery Directive (MD) 98/37/EC, the Low Voltage Directive (LVD) 2006/95/EC and the EMC Directive 2004/108/EC.
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationSP-RANGE INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR SP12 & SP25 SERIES 4
SP-RANGE INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR SP12 & SP25 SERIES 4 Imperial Machine Company Limited Unit 1, Abbey road Wrexham Industrial Estate Wrexham, LL13 9RF Tel: +44 (0)1978
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationBR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators
BR I Blood Bank Refrigerators 9.9707.50 09/015 > Legally safe storage of blood at +4 C > In compliance with international standards and directives BIOMEDICAL REFRIERATION Innovative and reliable refrigeration
More informationBlue. Efficient design, optimized performance. Alfa Laval Blue Enhanced design for outdoor duty
Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers optimize the performance
More informationPlanning guide. Atec.
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationHIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS
Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose
More informationBHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:
INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationDEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE
DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE 1 SUMMARY 1. GENERAL..... 3 1.1 General terms of delivery.... 3 1.2 Voltage... 3 1.3 Standards. 3 2. DESCRIPTION.... 3 2.1 Presentation..... 3 2.2
More informationCONTENTS. 1.1 General terms of delivery Voltage Water treatment... 2
CONTENTS 1 General... 2 1.1 General terms of delivery... 2 1.2 Voltage... 2 1.3 Water treatment... 2 2 Description... 2 2.1 Presentation... 2 2.1.1 Edenpac 2, 3, 4 and 5 2.1.2 Edenpac 6 2.2 Dimensional
More informationPGDX Rectangular duct coolers with DX coil
PGDX Rectangular duct coolers with DX coil Rectangular duct coolers with DX Coil PGDX Rectangular duct coolers with DX coil The PGDX is used for central cooling of the ventilation air in a ventilation
More informationINFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.
INFO DUAL Compact GADC Air Cooler for HFC and CO 2 Dual discharge air cooler with and without integrated condensation water pump 2 25 kw As you see, you see nothing Where has the condensation water drain
More information1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationAIR COOLERS FOR WIDE RANGE OF APPLICATIONS
Goedhart air coolers Goedhart StSt/Al - StSt/StSt air coolers AIR COOLERS FOR WIDE RANGE OF APPLICATIONS Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationInstallation manual Washer extractor
Installation manual Washer extractor W555H Type W.55.H Original instructions 438 9054-30/EN 2017.11.06 Contents Contents 1 Safety Precautions...5 1.1 General safety information...6 1.2 Commercial use
More informationUSER GUIDE. TL6015W TL6018W 60cm Larder
USER GUIDE TL6015W TL6018W 60cm Larder Thank you for buying this high quality appliance This handbook is designed to help you through each step of owning your new appliance, from installation to use. Please
More informationOPERATING INSTRUCTIONS
TECHNICAL INFORMATION OPERATING INSTRUCTIONS BITZER AUSTRALIA BUFFALO TRIDENT HEAT EXCHANGE Models PS1LE016 PS2LE233 Content 1 Important Recommendations 2 Safety Recommendations 3 Application Ranges 4
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for
More informationFWC153, FWC304, FWC604 & FWC624
FWC153, FWC304, FWC604 & FWC624 Wine Coolers Installation, use and maintenance www.cda.eu Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation
More informationKüba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing
High-performance air cooler for blast chilling and shock freezing engineering for a better world GEA Heat Exchangers High-performance air cooler for blast chilling and shock freezing Large fin spacing
More informationFWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance
FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E :
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products, Inc. 700 Thimble Shoals Blvd, Suite 109 Newport News, VA. 23606-2575 Tel: (757) 873 6800 Fax: (757) 873 3632
More informationHi-Pres Cooling Products Catalogue. Product Catalogue
Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationBRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.
More information
Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationCR64-1 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationCR A-F-A-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html
More informationLOW PROFILE EVAPORATORS
PS SERIES & PSL SERIES LOW PROFILE EVAPORATORS MEDIUM & LOW TEMPERATURE EVAPORATORS ORIGINAL MANUFACTURED EQUIPMENT PS Series PSL Series HX-404-3 AUS Product Specifications The PS Series Low Line Evaporators
More informationSPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC
APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationInstallation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control
manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:
More informationCRN A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html
More informationTechnical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging
Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013
More informationFRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY
FRAL SRL via dell industria e dell artigianato, 22/C - 35010 Carmignano di Brenta - PADOVA - ITALY TELPHONE: +39 049 9455839 FAX: +39 049 5991129 E-MAIL: info@fral.it WEB: www.fral.it DEHUMIDIFIERS FD
More informationLH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.
H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions. H and GH/G SERIES UNIT COOERS H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height,
More information30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw
Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER 30G - 50 Hz Nominal cooling capacity 384-03 kw The 30G units are air-cooled chillers, designed from the ground up to meet the needs of today and
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationBOILING PANS GAS & ELECTRICS
PREMIUM BOILING PANS GAS & ELECTRICS MANUFACTURER'S INSTRUCTIONS Part A: Technical data Part B: Installation manual - WARNING - Installation and repairs must be carried out by personnel approved by the
More informationInstallation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke
918149-0 GB Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Transport 3. Storage 4. Installation 4.1 Prior to attachment 4.2 Attachment
More informationINSTALLATION AM ; AMC
INSTALLATION AM 0. 00. 00. 800; AMC 0.. SAFETY INSTRUCTIONS This Manual must be read before installing the Airmaster air handling unit. Following this Manual will ensure this product is operated correctly.
More informationATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech
AKING ODERN LIVING POSSIBLE Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech
More informationPURESTREAM. ACW Air Cooled Fluid Cooler User and Maintenance Manual AMBIENT FLUID COOLER BY FRIULAIR
PURESTREAM AMBIENT FLUID COOLER BY FRIULAIR ACW Air Cooled Fluid Cooler User and Maintenance Manual Dear Customer, Please read this manual carefully in order to obtain the best performance from our products.in
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationTechnical documentation
Technical documentation AIR WATER HEATERS IN STEEL CASING S SERIES MODELS: REVENTON GROUP S1-3S REVENTON GROUP S2-3S REVENTON GROUP S3-3S REVENTON GROUP S4-3S ENG TECHNICAL DOCUMENTATION Table of contents
More informationCENTRIFUGAL AIR CONDENSERS
OPERATING INSTRUCTIONS INSTALLATION COMMISSIONING OPERATING MAINTENANCE (must be given to the end user in order to complete the operating manual during the equipment service life) CAC and SIROCCO CENTRIFUGAL
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More information