Hi-Pres Cooling Products Catalogue. Product Catalogue

Size: px
Start display at page:

Download "Hi-Pres Cooling Products Catalogue. Product Catalogue"

Transcription

1 Hi-Pres Cooling Products Catalogue Product Catalogue

2 Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product development. Copyright (c) , Novenco A/S. All rights reserved. Trademarks The following are registered trademarks of Novenco A/S and Novenco Building & Industry A/S. NOVENCO Novenco, Chinese script Novenco, Chinese script Novenco, Chinese script The following are registered trademarks of Novenco Marine & Offshore A/S. Hi-Pres HI-PRES Hi-Pres, Chinese script Hi-Pres, Chinese script Novenco is a registered trademark of Novenco A/S and Novenco Marine & Offshore A/S. ZerAx is a registered trademark of Novenco A/S and Novenco Building & Industry A/S. Other trademarks appearing in this document are the property of their respective owners. 1

3 Product Catalogue Table of contents Marine chillers, QCM... 3 Introduction... 3 Nomenclature... 3 Product family overview... 4 QCM-P(S,T)-BHE... 5 Capacity overview chart... 5 Advantages & application... 6 Scope of supply... 6 Technical specifications... 6 QCM-SS-BHE... 7 Capacity overview chart... 7 Advantages & application... 8 Scope of supply... 8 Technical specifications... 8 QCM-S(S,T)-ST... 9 Capacity overview chart... 9 Advantages & application Scope of supply Technical specifications QCMB - Marine Box Chiller Capacity overview chart Advantages & application Scope of supply Technical specifications Refrigeration Provision Plants Introduction Advantages & application Air cooler NovPAC Marine Self-contained A/C Casing Compressor Air cooler Fan Condenser-Air cooled Condenser-Water cooled Shell & tube Features NovPAC-R contents NovPAC-G contents Unit controls Optional supply Specifications-water cooled type Specification -air cooled type More Product Pictures Product Certificates A/C Direct Expansion Units Introduction Capacity overview chart Advantages & application Scope of supply

4 Marine Chillers, QCM INTRODUCTION The individual Marine chiller is designed for a cooling capacity ranging from 30-10kW. All system components are dimensioned and calculated for optimal performance at the required design parameters. The performance of the cooling plants depend on how the actual system parameters compare to the system design parameters. The specially developed Novenco control system allows for optimal adjustment of the cooling capacity. The unit output is accurately controlled within the range specified for individual compressors. In order to prevent the risk of low capacity operation, the unit automatically will stop when the output demand drops below minimum compressor capacity and will restart after a preset delay time when the output demand again rises above the minimum compressor capacity. The unit has passed a rigorous quality inspection and testing procedure prior to final factory approval and packing. NOMENCLATURE QCM: Default unit type B: Box Chiller P: Piston compressor S: Screw compressor QCM(B) - P S XXX - BHE S: Single system T: Twin system XXX: Cooling capacity BHE: Brazed Heat Exchanger ST: Shell and Tube Note: QCM(B) = Cooling Chiller Marine (Box) 3

5 Product Catalogue Product family overview Product Family Overview - QCM 1800 Cooling capacity/ kw Min Max Note: BHE = Brazed heat exchanger; ST = shell & tube 4

6 Marine Chillers, QCM QCM-P-(S,T)-BHE Single Twin Capacity overview for QCM-PS-BHE Chiller 6/12[ o C] 2 Cooling capacity/ kw QCM30 QCM60 QCM80 QCM90 QCM120 QCM1 QCM180 QCM Min Max Note: Unit code covers Hz, 60Hz - 6/12 range, 60Hz - 8/12 range As for QCM-PT-BHE, max will double while min remain 5

7 Product Catalogue ADVANTAGES AND APPLICATION Compact marine chiller, Piston compressor Designed optimized for marine application, compact & robust; Highly accurate capacity and temperature control system suited for AC as well as MGO/MDO cooling; High quality components for maximum reliability, endurance and minimum maintenance; SIEMENS PLC control of all unit functions. Touch screen interface for easy unit operation and status overview; Control of up to 4 independent chilled water consumers; Available both as single and twin versions for improved redundancy SCOPE OF SUPPLY Standard supply Semi-hermetic compressor, 400V/Hz, 440/690V/60Hz BHE water chiller ST condenser, Sea or freshwater SIEMENS electronic expansion valve Desmi chilled water pump Danfoss filters Software factory pre-load and function test. Standard options Manometers for chilled & cooling water Thermometers for chilled & cooling water Flexible connections for chilled & cooling water First charge of refrigerant and lubrication oil TECHNICAL SPECIFICATIONS - SIZE Chilled water Condenser 440V/60Hz R404A Cooling Overall unit dimension connections connections capacity Height Width Length Unit code [kw] Dry weight [Kg] Flange type [mm] [mm] [mm] QCM30-60/ DN32/PN10 DN QCM60-60/ DN32/PN10 DN QCM80-60/ DN40/PN10 DN65 QCM90-60/ DN40/PN10 DN65 QCM120-60/ DN40/PN10 DN80 QCM1-60/ DN40/PN10 DN65 QCM180-60/ DN40/PN10 DN64 QCM210-60/ DN/PN10 DN80 Chilled water Condenser 400V/Hz R404A Cooling Overall unit dimension connections connections capacity Height Width Length Unit code [kw] Dry weight [Kg] Flange type [mm] [mm] [mm] QCM30-/ DN32/PN10 DN QCM60-/ DN32/PN10 DN65 QCM90-/ DN40/PN10 DN65 QCM120-/ DN40/PN10 DN65 QCM1-/ DN40/PN10 DN80 QCM180-/ DN40/PN10 DN80 QCM210-/ DN/PN10 DN80 6

8 Marine Chillers, QCM QCM-SS-BHE Capacity overview for QCM-SS-BHE Chiller 6/12[ o C] Cooling capacity/ kw Min Max 0 QCM1 QCM170 QCM220 QCM260 QCM300 QCM330 QCM370 QCM420 QCM4 Note: Unit code covers & 60Hz range 7

9 Product Catalogue ADVANTAGES AND APPLICATION Compact marine chiller with screw compressor Designed optimized for marine application, compact & robust; Highly accurate capacity and temperature control system suited for AC & general chilled water application; High quality components for maximum reliability, endurance and minimum maintenance; SIEMENS PLC control of all unit functions. Touch screen interface for easy unit operation and status overview; Control of up to 4 independent chilled water consumers; Available both as single and twin versions for improved redundancy SCOPE OF SUPPLY Standard supply Compact screw compressor, 400V/Hz, 440/690V/60Hz BHE water chiller ST condenser, Sea or freshwater SIEMENS electronic expansion valve Desmi chilled water pump (optional) Danfoss filters Software factory pre-load and function test Standard options Manometers for chilled & cooling water Thermometers for chilled & cooling water Flexible connections for chilled & cooling water First charge of refrigerant and lubrication oil TECHNICAL SPECIFICATIONS - SIZE & CONSUMPTION Connections Condenser connections 440V / 60Hz R407C Cooling Overall unit dimension Chilled water capacity Height Width Length Dry weight Unit code [kw] Flange type [mm] [mm] [mm] [Kg] QCM1-FW-R407C-440/60-6-S DN80 DN100 QCM170-FW-R407C-440/60-6-S DN80 DN100 QCM220-FW-R407C-440/60-6-S DN80 DN100 QCM260-FW-R407C-440/60-6-S DN80 DN100 QCM300-FW-R407C-440/60-6-S DN80 DN125 QCM330-FW-R407C-440/60-6-S DN80 DN125 QCM370-FW-R407C-440/60-6-S DN80 DN125 QCM420-FW-R407C-440/60-6-S DN80 DN125 QCM4-FW-R407C-440/60-6-S DN80 DN V / 60Hz R407C QCM consumption Unit code Comp [kw] Comp [Amp] Condenser flow [m 3 ] Condenser water T o in C Condenser water T o out C Condenser water Δ o C Chilled water flow [m 3 ] QCM1-FW-R407C-440/60-6-S QCM170-FW-R407C-440/60-6-S QCM220-FW-R407C-440/60-6-S QCM260-FW-R407C-440/60-6-S QCM300-FW-R407C-440/60-6-S QCM330-FW-R407C-440/60-6-S QCM370-FW-R407C-440/60-6-S QCM420-FW-R407C-440/60-6-S QCM4-FW-R407C-440/60-6-S

10 Marine Chillers, QCM QCM-S(S,T)-ST Single Twin Capacity overview for QCM-SS-ST Chiller 6/12[ o C] Cooling capacity/ kw Min Max Note: Unit code covers & 60Hz range As for QCM-ST-ST, max will double while min remain 9

11 Product Catalogue ADVANTAGES AND APPLICATION Compact marine chiller with screw compressor Designed optimized for marine application, compact & robust; Highly accurate capacity and temperature control system suited for AC as well as MGO/MDO cooling; High quality components for maximum reliability, endurance and minimum maintenance; SIEMENS PLC control of all unit functions; Touch screen interface for easy unit operation and status overview; Control of up to 4 independent chilled water consumers; Basic system allows for 1-6 individual chillers to be easily connected to form a sequence controlled system; Available both as single and twin versions for improved redundancy SCOPE OF SUPPLY Standard supply Compact screw compressor, 400V/Hz, 440/690V/60Hz ST water chiller (single or twin circuit) ST condenser, Sea or freshwater SIEMENS electronic expansion valve Danfoss filters Software factory pre-load and function test Standard options Manometers for chilled & cooling water Thermometers for chilled & cooling water Flexible connections for chilled & cooling water First charge of refrigerant and lubrication oil 10

12 Marine Chillers, QCM TECHNICAL SPECIFICATIONS - SIZE & CONSUMPTION Chilled water Condenser 440V / 60Hz R407C Cooling Overall unit dimension connections connections capacity Height Width Length Dry weight Unit code [kw] Victaulic type [mm] [mm] [mm] [Kg] QCM1-FW-R407C-440/60-6-S "(DN80) 4"(DN100) QCM170-FW-R407C-440/60-6-S "(DN100) 4"(DN100) QCM220-FW-R407C-440/60-6-S "(DN100) 5"(DN125) QCM260-FW-R407C-440/60-6-S "(DN100) 5"(DN125) QCM300-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM330-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM370-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM420-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM4-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM0-FW-R407C-440/60-6-S "(DN1) 5"(DN125) QCM5-FW-R407C-440/60-6-S "(DN200) 5"(DN125) QCM600-FW-R407C-440/60-6-S "(DN200) 6"(DN1) QCM6-FW-R407C-440/60-6-S "(DN200) 6"(DN1) QCM700-FW-R407C-440/60-6-S "(DN200) 6"(DN1) QCM7-FW-R407C-440/60-6-S "(DN200) 6"(DN1) Chilled water Condenser 440V / 60Hz R407C Cooling Overall unit dimension connections connections capacity Height Width Length Dry weight Unit code [kw] Victaulic type [mm] [mm] [mm] [Kg] QCM300-FW-R407C-440/60-6-T "(DN1) 4"(DN100) QCM340-FW-R407C-440/60-6-T "(DN1) 4"(DN100) QCM440-FW-R407C-440/60-6-T "(DN1) 5"(DN125) QCM520-FW-R407C-440/60-6-T "(DN1) 5"(DN125) QCM600-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM660-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM740-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM840-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM900-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM1000-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM1100-FW-R407C-440/60-6-T "(DN200) 5"(DN125) QCM1200-FW-R407C-440/60-6-T "(DN200) 6"(DN1) QCM1300-FW-R407C-440/60-6-T "(DN200) 6"(DN1) QCM1400-FW-R407C-440/60-6-T "(DN2) 6"(DN1) QCM10-FW-R407C-440/60-6-T "(DN2) 6"(DN1) 11

13 Product Catalogue QCM consumption Compressor [kw] Compressor [Amp] Condenser flow [m 3 ] Condenser water T o in C Condenser water T o out C Condenser water Δ o C Chilled water flow [m 3 ] QCM unit consumption (based on each single parts) Compressor [kw] Compressor [Amp] Condenser flow [m 3 ] Condenser water T o in C Condenser water T o out C Condenser water Δ o C Chilled water flow [m 3 ]

14 Marine Chillers, QCM QCMB - Marine Box Chillers Capacity overview for QCMB Cooling capacity/ kw min max Note: Unit code covers 60Hz range 13

15 Product Catalogue ADVANTAGES AND APPLICATION Compact marine chiller with box enclosure Designed optimized for marine application, compact & robust; Highly accurate capacity and temperature control system perfectly suited for AC & general chilled water application; High quality components for maximum reliability, efficiency, endurance and minimum maintenance; Easy connection of up to 6 chillers in sequence - standard onboard option. SIEMENS PLC control of all unit functions. Full color touch screen interface for easy unit operation and status overview; remote device control option built in as standard; Control of up to 4 independent chilled water consumers per unit; Designed to be arranged as twin module, units arranged with one placed on top SCOPE OF SUPPLY Standard supply Compact screw compressor, 400V/Hz, 440/690V/60Hz BHE water chiller ST condenser, Sea or freshwater SIEMENS electronic expansion valve Desmi chilled water pump (optional) Danfoss filters Software factory pre-load and function test Standard options Manometers for chilled & cooling water Thermometers for chilled & cooling water Flexible connections for chilled & cooling water First charge of refrigerant and lubrication oil Technical Specifications Name code Model QCMB-SSXXX-BHE-FW-R407C-440/ Cooling capacity [kw] Power consumption [kw] Rated current [A] Refrigerant R407C Power supply 440V/3~/60Hz Condensing source Fresh water 6 oc Outlet water temperature Unit dimension (L*D*H) [mm3] Compressor type Box #1 Box #2 20*1000*1000 (incl. control box) 20*1000*15 (incl. control box) Semi-hermetic screw compressor Condenser type Shell & tube Evaporator type Brazed heat exchanger 14

16 A/C Direct Expansion Units, QDX INTRODUCTION The individual Air Conditioning Direct Expansion Units is designed for a cooling capacity ranging from -260kW. All system components are dimensioned and calculated for optimal performance at the required design parameters. The performance of the cooling plants depend on how the actual system parameters compare to the system design parameters. The specially developed Novenco control system allows for optimal adjustment of the cooling capacity. The unit output is accurately controlled within the range specified for individual compressors. In order to prevent the risk of low capacity operation, the unit automatically will stop when the output demand drops below minimum compressor capacity and will restart after a preset delay time when the output demand again rises above the minimum compressor capacity. The unit has passed a rigorous quality inspection and testing procedure prior to final factory approval and packing. Capacity overview for QDX A/C Direct Expansion Unit 300 Cooling capacity/ kw Min Max 0 OP-R407C OP-404A OP-R134a SP-407C SP-404A SP-R134a SS-R407C SS-R134a Note: OP = open piston; SP = semi-hermetic piston; SS = semi-hermetic screw Note: QDX = Cooling Direct expansion 15

17 Product Catalogue ADVANTAGES AND APPLICATION Modular standardized condensing unit, piston & compact or compact screw compressor Designed optimized for air conditioning, compact & robust Highly accurate capacity and temperature control system uited for AC as well as MGO/MDO cooling High quality components for maximum reliability, endurance and minimum maintenance Marine proof compressors, semi-hermetic or open type direct driven piston and semi-hermetic compact screw; Designed for operation with approved HFC refrigerants Ethernet connection enabling remote control to any PC on-board Environmental friendly design, on request the design may comply with all environmental certifications (LRS, DNV-GL, ABS, BV, RINA, etc.) Protective coating category C2 HIGH is using a paint system complying with EN ISO Standard colour is RAL 01, and can be changed to other standard RAL colours to meet customer requirements Compressor capacity regulation down to 25-33%, ensuring smooth operation without short cycling in part load conditions Easy maintenance despite the compact design Condenser holding the refrigerant charging during operational pumpdown Pre-assembled valve boards ensuring trouble-free installation on-board Factory pressure and leak testing of all units prior to shipment Combined suction accumulator and sub-cooler for long on-board piping distances Fresh or sea water proof condensers 3D documentation of all plants for easy integration SIEMENS PLC control of all unit functions Four types of system configurations are available: 1 or 2 QDXs with 1 or 2 AHUs Touch screen interface for easy unit operation and status overview R404A as standard, R134a and R407C as alternatives 16

18 A/C Direct Expansion Units, QDX SCOPE OF SUPPLY Standard supply Semi-hermetic/open type compressor, 400V/Hz, 440V/60Hz Robust shell & tube condenser for sea or fresh water Danfoss filters 2-in-1 suction accumulator and sub-cooler One-side service and unit state monitoring design Combined suction accumulator and sub-cooler Manometers for suction & discharge pressure Temperature sensor for suction pipe of AHU Flexible connections for connecting QDX to AHU First charge of refrigerant and lubrication oil Standard options Oil separator Additional sub-cooler Liquid receiver 17

19 Product Catalogue Refrigeration Provision Plants, QPP INTRODUCTION The individual QPP Refrigeration Provision Plant is designed for a cooling capacity ranging from 2-18kW. All system components are dimensioned and calculated for optimal performance at the required design parameters. The performance of the cooling plants depend on how the actual system parameters compare to the system design parameters. The specially developed Novenco control system allows for optimal adjustment of the cooling capacity. The unit output is accurately controlled within the range specified for individual compressors. In order to prevent the risk of low capacity operation, the unit automatically will stop when the output demand drops below minimum compressor capacity and will restart after a preset delay time when the output demand again rises above the minimum compressor capacity. The unit has passed a rigorous quality inspection and testing procedure prior to final factory approval and packing. Note: QPP = Cooling Provision Plant 18

20 Refrigeration Provision Plants, QPP ADVANTAGES AND APPLICATION Complete system supply - Condensing unit, open or semi-hermetic type - Air cooler(s) - Control panel, PLC system control - Necessary system components Simultaneous control of 8 individual cold storage rooms Intelligent defrost, energey efficient Quick freeze function Compact design insures both easy maintenance and minimum footprint AIR COOLER Wiring and valves pre-installed (internally) Easy cleanable High efficiency Hinged drip-pan As standard the Novenco system can handle up to 8 individually rooms in the provision plant system Total standard cooling capacity range, 2 18 kw 19

21 Product Catalogue NovPAC Marine Self-contained A/C WATER-COOLED TYPE (PLENUM) CASING Cold-rolled steel sheet casing built on a rigid galvanized steel frame. The casing is thermally insulated to prevent condensation and surface treatment by plastic spraying to resist corrosion. Plenum with adjustable grill and fresh air intake is optional. COMPRESSOR NovPAC-R/G models use hermetic reciprocating compressors. The compressors are fitted with heating elements and an internal suction accumulator (for azeotropic refrigerant) to ensure long life operation. AIR COOLER Cu/Cu coil for NovPAC-G, Cu/Al coil for NovPAC-R. The evaporation process is secured by a thermostatic expansion valve. A washable flat filter is placed in front of the air coil. The unit has a drip tray with extra depth to take pitch and roll into considerations. Material of drip tray is plastic spraying treated cold-rolled steel sheet, and stainless steel sheet is optional. WATER-COOLED TYPE (DUCT CONNECTION) FAN For optimum sound reduction a dual fan program is applied: fans with low static pressure for plenum to ensure a low noise level and high static pressure for duct connection, centrifugal fan with motor V-belt coupled. Note: NovPAC = Novenco Packaged Air Conditioning For NovPAC-R/G, R stands for Return and G stands for Galley 20

22 NovPAC Marine Self-contained A/C AIR-COOLED TYPE (INDOOR UNIT) AIR-COOLED TYPE (OUTDOOR UNIT) CONDENSER - AIR COOLED The air cooled condenser is a component supplied separated from the main NovPAC unit to be connected on site, allowing for optiomal flexibility in installation. AIR-COOLED TYPE (OUTDOOR UNIT) CONDENSER - WATER COOLED SHELL & TUBE A cleanable shell-and-tube condenser wiht 90/10 Cu/Ni tubes is used for sea water, and a cast iron shell and Cu tube condenser for freshwater. Automatic seawater valves and air cooled condenser are optional. 21

23 Product Catalogue FEATURES Packaged air conditioners NovPAC-R/G are specially designed for use in marine and offshore installations. These units can be used for all kinds of small capacity air conditioning requirements. Cooling coil for direct expansion High-efficiency centrifugal fan Hermetic reciprocating compressor with low sound generation Cu/Ni shell and tube condenser or seawater, a cast iron shell and Cu tube condenser for freshwater, a Cu/Al air cooled condenser for air Control panel wiht motor protection by thermal oveload relay, temperature control and compressor control Thermostatic temperature control Standard refrigerant R404A, R407C, or R134a Standard range of units for 3x400V/Hz or 3x440V/60Hz for freshwater, seawater or air cooled condenser. Air filter (EU-2), EU-4 is optional NOVPAC-R CONTENTS Specially designed for recirculation systems, e.g. for ECR (Engine Control Room), etc. with capacities from 6-98kW UNIT CONTROLS A digital temperature controller, with LED and sensors placed in the air flow, ensures the correct temperature. The LED is located on the small panel in front of the unit as well as switch knob for choosing operation mode such as cool, heat, ventilation or remote on/off of optional equipment. The electric panel includes automatic circuit breakers. The compressor safety equipment includes HP/LP switches, filter/ drier and liquid refrigerant sight glasses, and fittings to plug in pressure gauges. OPTIONAL SUPPLY Plenum Damper for fresh air intake and/or counter flanges Return air intake for a duct connection Flexible connections and counter flanges for air intake and outlet Stainless steel casing Cu/Cu cooling coil Electric heating coil Automatic seawater valve Pressure gauges NOVPAC-G CONTENTS Specially designed for Galley, with capacities from 10- kw 22

24 NovPAC Marine Self-contained A/C Specifications - Water-cooled type Cooling capacity [kw] # Comp. motor power consumption [kw] # Coolin [m 3 / Type R404A R407C R134a R404A R407C R134a R404A R SW FW SW FW SW FW SW FW SW FW SW FW SW FW SW NovPAC-R6 7.2/ / / / / / / / / / / / / / / 2.7 NovPAC-R / / / / / / / / / / / / / / / 3.9 Single system NovPAC-R14 NovPAC-R / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 5.9 NovPAC-R / / / / / / / / / / / / / / / 6.6 NovPAC-R NovPAC-R / / / / / / / / / / / / / / / 9.3 (Return air) NovPAC-R *2/ 19.8*2 15.3*2/ 19.2*2 15.0*2/ 17.9*2 13.9*2/ 16.7*2 10.3*2/ 13.1*2 9.6*2/ 12.3*2 5.4*2/ 7.2*2 5.7*2/ 7.4*2 4.5*2/ 5.4*2 4.7*2/ 5.7*2 3.1*2/ 4.1*2 3.3*2/ 4.3*2 11.4/ / / 11.8 NovPAC-R *2/ 24.5*2 19.3*2/ 22.5*2 18.9*2/ 22.7*2 17.6*2/ 21.3*2 13.5*2/ 16.3*2 12.6*2/ 15.4*2 7.2*2/ 9.5*2 7.5*2/ 9.8*2 5.9*2/ 7.0*2 6.1*2/ 7.3*2 4.1*2/ 5.3*2 4.2*2/ 5.5*2 14.5/ / / 15.0 Twin system NovPAC-R NovPAC-R *2/ 29.7*2 32.4*2/ 36.8*2 23.0*2/ 27.2*2 29.6*2/ 34.0*2 23.4*2/ 28.5*2 30.2*2/ 36.4*2 21.7*2/ 26.7*2 28.3*2/ 33.9*2 15.5*2/ 19.0*2 19.2*2/ 23.5*2 14.6*2/ 17.7*2 17.9*2/ 22.0*2 7.8*2/ 9.4*2 10.1*2/ 12.2*2 8.2*2/ 9.9*2 10.6*2/ 12.9*2 6.7*2/ 8.2*2 8.5*2/ 10.8*2 7.1*2/ 8.7*2 9.0*2/ 11.3*2 5.5*2/ 5.8*2 5.4*2/ 6.9*2 4.7*2/ 5.9*2 5.7*2/ 7.1*2 16.9/ / / / / / 23.9 NovPAC-R *2/ 43.2*2 33.9*2/ 39.8*2 33.5*2/ 40.9*2 31.3*2/ 38.5*2 23.5*2/ 28.1*2 22*2/ 26.5*2 11.7*2/ 14.5*2 12.3*2/ 15.1*2 9.7*2/ 12.0*2 10.2*2/ 12.7*2 6.8*2/ 8.5*2 7.0*2/ 8.9*2 25.0/ / / 26.8 NovPAC-R *2/ 46.7*2 37.1*2/ 43.0*2 38.2*2/ 45.4*2 35.8*2/ 42.6*2 25.8*2/ 31.1*2 24.2*2/ 29.4*2 13.6*2/ 16.8*2 14.2*2/ 17.5*2 11.3*2/ 14.1*2 11.9*2/ 14.8*2 7.5*2/ 9.6*2 7.8*2/ 10.0*2 27.7/ / / 30.1 NovPAC-G / / / / / / / / / / / / / / / 4.1 NovPAC-G / / / / / / / / / / / / / / / 4.3 NovPAC-G Single system NovPAC-G17 NovPAC-G / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 6.5 (Total fresh air) NovPAC-G / / / / / / / / / / / / / / / 8.9 NovPAC-G / / / / / / / / / / / / / / / 11.1 Twin system NovPAC-G42 NovPAC-G 21.0*2/ 24.6*2 23.6*2/ 27.4*2 19.3*2/ 22.6*2 21.7*2/ 25.2*2 18.3*2/ 21.8*2 20.6*2/ 24.6*2 17.1*2/ 20.5*2 19.2*2/ 23.1*2 13.6*2/ 16.3*2 15.4*2/ 18.4*2 12.7*2/ 15.4*2 14.5*2/ 17.4*2 6.3*2/ 8.5*2 7.4*2/ 9.9*2 6.6*2/ 8.8*2 7.7*2/ 10.2*2 5.5*2/ 6.5*2 6.0*2/ 7.2*2 5.8*2/ 6.8*2 6.3*2/ 7.6*2 3.6*2/ 5.8*2 4.2*2/ 5.6*2 3.8*2/ 5.0*2 4.4*2/ 5.8*2 15.0/ / / / / / 17.8 Note: # /60 Hz; SW = sea water; FW = fresh water; *2 = two compressors Limitations: Maximum air inlet temp.: 55oC. Minimum air inlet temp.: -20oC. Minimum cooling water temp.: 20oC Owning to continued product development Novenco reserves the right to introduce alterations without prior notice 23

25 Product Catalogue g water flow rate h] # Cooling water pre. loss [Kpa] For duct connection With plenum Electric heating capacity [kw] Dimensions & Weight H x W x D / Weight [mm 3 / kg] 407C R134a R404A/ R407C/ 134a FW SW FW SW/FW Air flow [m 3 /h] # R404A/ R407C R134a Unit external static pressure [Pa] R404A/ R407C/ R134a Motor power input [kw] # R404A/ R407C/ R134a R404A/ R407C Air flow [m 3 /h] # R134a Motor power input [kw] # R404A/ R407C/ R134a R404A/ R407C R134a Duct connection Plenum 2.1/ / / / / / / / / x 700 x 5 / x 700 x 5 / / / / / / / / / / x 800 x 5 / x 800 x 5 / / / / / / / / / / x 900 x 580 / x 900 x 580 / / / / / / / / / / x 10 x 580 / x 10 x 580 / / / / / / / / / / x 1100 x 700 / x 1100 x 700 / / / / / / / / / / x 1200 x 700 / x 1200 x 700 / / / / / / / / / / x 14 x 700 / x 14 x 700 / / / / / / / / / / x 1700 x 800 / x 1700 x 800 / / / / / / / / / / x 1900 x 900 / x 1900 x 900 / / / / / / / / / / x 1900 x 900 / x 1900 x 900 / / / / / / / / / / x 2000 x 1000 / x 2000 x 1000 / / / / / / / / / / x 2000 x 1000 / x 2000 x 1000 / / / / / / / x 800 x 5 / / / / / / / x 900 x 580 / / / / / / / x 10 x 580 / / / / / / / x 1100 x 700 / / / / / / / x 1200 x 700 / / / / / / / x 14 x 700 / / / / / / / x 1700 x 800 / / / / / / / x 1900 x 900 /

26 NovPAC Marine Self-contained A/C Specifications - Air-cooled type Cooling capacity [kw] # Comp. motor power consumption [kw] # Air outlet type - Duct connection Air outlet type - With plenum Type R404A R407C R134a R404A R407C R134a Air flow [m 3 /h] # R404A/ R407C R134a External static pressure [Pa] R404A/ R407C/ R134a Motor power input [kw] # R404A/ R407C/ R134a R404A/ R407C Air flow [m 3 /h] # R134a Motor input [ R40 R407C/ NovPAC-AR6 6.0/ / / / / / / / / / / NovPAC-AR10 8.3/ / / / / / / / / / / Single system NovPAC-AR14 NovPAC-AR / / / / / / / / / / / / / / / / / / / / / / NovPAC-AR / / / / / / / / / / / NovPAC-AR NovPAC-AR / / / / / / / / / / / (Return air) NovPAC-AR *2/ 16.4*2 12.9*2/ 15.6*2 8.9*2/ 11.5*2 6.0*2/ 7.6*2 4.9*2/ 5.9*2 3.4*2/ 4.4*2 5600/ / / / / NovPAC-AR *2/ 20.3*2 16.4*2/ 19.9*2 11.8*2/ 14.4*2 7.8*2/ 10.1*2 6.3*2/ 7.6*2 4.3*2/ 5.6*2 7000/ / / / / Twin system NovPAC-AR NovPAC-AR *2/ 24.8*2 26.9*2/ 31.5*2 20.0*2/ 24.6*2 26.3*2/ 30.9*2 13.4*2/ 20.2*2 16.6*2/ 30.9*2 8.6*2/ 9.1*2 11.1*2/ 13.6*2 7.4*2/ 10.3*2 9.5*2/ 13.6*2 4.9*2/ 6.1*2 5.9*2/ 7.2*2 8400/ / / / / / / / / / NovPAC-AR *2/ 36.2*2 29.1*2/ 36.0*2 20.5*2/ 24.8*2 12.8*2/ 15.7*2 10.7*2/ 13.3*2 7.3*2/ 9.2* / / / / / NovPAC-AR *2/ 39.2*2 33.4*2/ 39.3*2 22.5*2/ 27.5*2 14.8*2/ 18.2*2 12.5*2/ 18.2*2 8.0*2/ 10.2* / / / / / NovPAC-AG10 8.4/ / / / / / / / / NovPAC-AG14 9.4/ / / / / / / / / NovPAC-AG (Total fresh air) Single system NovPAC-AG17 NovPAC-AG20 NovPAC-AG / / / / / / / / / / / / / / / / / / / / / / / / / / / NovPAC-AG / / / / / / / / / Twin system NovPAC-AG42 NovPAC-AG 16.8*2/ 19.8*2 18.9*2/ 22.1*2 15.8*2/ 19.1*2 17.9*2/ 21.6*2 15.8*2/ 19.1*2 17.9*2/ 21.6*2 6.8*2/ 8.9*2 8.0*2/ 10.4*2 5.7*2/ 6.9*2 6.6*2/ 7.9*2 5.7*2/ 6.9*2 6.6*2/ 7.9*2 3800/ / / / / / Note: # /60 Hz; *2 = two compressors Owning to continued product development Novenco reserves the right to introduce alterations without prior notice 25

27 Product Catalogue 26 Electric heating capacity [kw] Outdoor fan power kw] # R404A/ R407C R134a Fan air flow [m 3 /h] # Motor power input [kw] # 4A/ R134a R404A/ R407C/ R134a R404A/ R407C/ R134a 5/ 2 EH-3 EH / / / 2 EH-6/3 EH-6/3 5700/ / / 2 EH-9/6/9 EH-9/6/3 70/ / / 5 EH-12/9/6 EH-12/9/ / / / 5 EH-15/12/9 EH-15/12/ / / / 0 EH-18/15/12 EH-18/15/ / / / 0 EH-21/18/15 EH-21/18/ / / / 0 EH-24/21/18 EH-24/21/ / / / 0 EH-30/24/21 EH-27/24/ / / / 0 EH-36/30/24 EH-30/27/ / / / 0 EH-45/36/30 EH-33/30/ / / / 0 EH-54/45/36 EH-36/33/ / / EH-6 EH / / EH-9/6 EH-6/3 70/ / EH-12/9/6 EH-9/6/ / / EH-15/12/9 EH-12/9/ / / EH-21/15/12 EH-15/12/ / / EH-27/21/15 EH-18/15/ / / EH-33/27/21 EH-24/18/ / / EH-39/33/27 EH-27/24/ / / 1.209

28 More Product Pictures We can provide more QCM-SS-BHE 2. QCM-ST-ST 3. QCM-SS-ST 4. QCM-PT-BHE 5. QCM-PT-ST 6. QCM-ST-BHE 7. QCM-PS-BHE 8. SCU-C 9. SCU-C 10. QDX with screw compressor 11. QDX with piston compressor 12. QDX with scroll compressor 13. Pump skid (1) (3) (2) (4) (5) 27

29 Product Catalogue (6) (7) (8) (10) 28

30 More Product Pictures (9) (11) (12) (13) 29

31 Product Catalogue Product Certificates 30

32 MU Novenco develops and manufactures heating, ventilation, air conditioning, refrigeration and cooling systems marketed and distributed worldwide through subsidiaries and agents. The company was founded in Denmark in 1947 and has become one of the world-leading suppliers of high quality energy efficient systems. Read more about Novenco Marine & Offshore on our website Novenco is a registered trademark of Novenco A/S and Novenco Marine & Offshore A/S., and NOVENCO are registered trademarks of Novenco A/S and Novenco Building & Industry A/S. Hi-Pres, HI-PRES and are registered trademarks of Novenco Marine & Offshore A/S. ZerAx is a registered trademark of Novenco A/S and Novenco Building & Industry A/S. Other trademarks appearing in this document are the property of their respective owners. Owing to continued product development Novenco Marine & Offshore reserves the right to introduce alterations without prior notice

Hi-Pres Cooling Products Catalogue

Hi-Pres Cooling Products Catalogue Sales offices: Novenco Marine & Offshore A/S Industrivej 22 4700 Naestved Denmark Tel:+45 7012 4222 Fax:+45 5575 65 E-mail: info@novencogroup.com Novenco A.S. Karenslyst Allé 11 N-0278 Oslo Norway Tel:+47

More information

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

500 EX Fusion Compressor Series

500 EX Fusion Compressor Series 500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e. ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60 Unit Dimension Unit Nomenclature DEHUMIDIFIER NOMENCLATURE R K D A - 0050 - C Z - M 4-8 UNIT VOLTAGE: 2: 240/1/60 5: 208-240/3/60 9: 480/3/60 8: 600/3/60 REFRIGEREANT R-404a MEDIUM TEMPERATURE SCROLL COMPRESSOR

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

OACS Outdoor Air-Cooled Central Chillers

OACS Outdoor Air-Cooled Central Chillers OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single

More information

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV Table of Contents Nomenclature Chart... 2 Features and Benefits...3

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Central Chillers & Pump Tanks C E N T R A L C H I L L E R S 30RAP Series Central Chillers 10-60 Tons 30RAP Series air-cooled central

More information

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Product Data Catalog Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X Variable Speed Total Access Modules MS010W, MS020W, MS030W, MS050W MS010V, MS020V,

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System

More information

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G Large Rooftop DIC-BIH-DIG 360 to 480 G Large Rooftop DIC-BIH-DIG A complete range from 119.1 kw up to 155.6 kw R407C Features Adjustable roof curb types YKlon 33 board Duct work configuration side or down

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 08/2017 1 PLEXUS CATALOGUE 08/2017 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller AWC Series - Single Chiller...

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz 30GXN-3SB 30GXN,R080-528 AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz PERFORMANCE DATA S FIELD WIRING DIAGRAMS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form 30GXN-3SB

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

General Catalogue. FORM SSI - G.C (94)

General Catalogue. FORM SSI - G.C (94) FORM SSI - G.C (94) www.ssi.co.ir General Catalogue INDEX 09CDF 16DNS 16DES 16JBP 16JBP Air Cooled Condenser Air Cooled Condenser Absorption Chiller Double Effect Direct Fired Absorption Chiller Double

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

30KAV Variable Speed Air-cooled Screw Chiller

30KAV Variable Speed Air-cooled Screw Chiller 0KAV Variable Speed Air-cooled Screw Chiller Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning and refrigeration

More information

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel. DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the

More information

Condensing Units w/ Screw Compressors

Condensing Units w/ Screw Compressors w/ Compressors Overview Increased Reliability Fewer moving parts result in improved durability Semi-hermetic motor design eliminates shaft seal and coupling concerns Integral oil system provides improved

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure

More information

Features. protection. durable. low vibration. application. optional. Indoor unit Outdoor unit (side fan) Outdoor unit (top fan)

Features. protection. durable. low vibration. application. optional. Indoor unit Outdoor unit (side fan) Outdoor unit (top fan) Marine Air-cooled ackaged Air Conditioner escription The air-cooled packaged air conditioner is specially designed for offshore application, and other locations such as engine control room, workshop, switchboard

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Air Cooled Scroll Chiller / Heat Pump

Air Cooled Scroll Chiller / Heat Pump Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

air systems Roomtop RTC-RTH 15 to 30 - L

air systems Roomtop RTC-RTH 15 to 30 - L air systems Roomtop RTC-RTH 15 to 30 - L york air-conditioning products Roomtop RTC-RTH - L A complete range from 14.6 kw up to 27.0 kw YKN2open Features New YKN2open board Possibility to be installed

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307 DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

Commercial and Technical Data

Commercial and Technical Data Chillers Commercial and Technical Data Air Cooled Single Circuit Condensing Unit» Wide capacity range (120 kw - 490 kw)» One refrigerant circuit with single screw compressor» Two sound versions available»

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Scroll Water Cooled Chiller

Scroll Water Cooled Chiller Scroll Water Cooled Chiller SRW145 Nominal Cooling Capacity 77 to 1232 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data 5 Unit Performance 8 Chiller Selection 9 Physical

More information

SCA 620C AIR COOLED SCREW CHILLER

SCA 620C AIR COOLED SCREW CHILLER DUNNAIR I N T E R N A T I O N A L L I M I T E D SCA 620C AIR COOLED SCREW CHILLER MV6 CONTROL Refrigerant: R22 Standard NOMINAL CAPACITY 620 kw(r) DUNNAIR INTERNATIONAL LIMITED Subject to change without

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...

More information

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

EN aquatech.piovan.com

EN aquatech.piovan.com EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.

More information

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE. Portable Chillers s P O RTA B L E C H I L L E R S SMC Series 1/2 to 3-1/2 HP Portable Chiller SMC ½ to 1½ HP Features: Environmentally

More information

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Multi-Scroll Air-Cooled Liquid Chillers Nominal cooling capacity: 167-582 kw 50 Hz EKS/BS business The picture refers to the model: EKS - BP / BS/AS 2 The competitive choice Air

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Mechanical Systems Mechanical Systems

Mechanical Systems Mechanical Systems VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell

More information

Specification Data. General:

Specification Data. General: Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to

More information

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY C A P A C I T Y R U G G E D, I N D O O R/ R E A D Y T O T O T A L L O C A L M A T C H E D O U T D O O R D E S I G N I N S T A L L S U P P O R T E N V I R O N M E N T A L C O N T R O L Liebert Industrial

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

EMI ENGINEERING SUBMITTAL

EMI ENGINEERING SUBMITTAL (MH4) MULTI-ZONE HEAT PUMP AIR CONDITIONING SYSTEM Rev. 1.4 [3/05] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT DESIGNATION:

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

Central Chillers TS Series

Central Chillers TS Series www.thermalcare.com Central Chillers TS Series With over 40 years of process cooling experience, Thermal Care is the dependable choice for industrial process chillers. Our TS Series is just one of several

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

F Series - Refrigeration dryers

F Series - Refrigeration dryers F Series - Refrigeration dryers Quality compressed Air Flows from 0,38 to 110 m 3 /min QUALITY, DRY COMPRESSED AIR: THE EFFECTS: Considerably reduced production costs. Circuit protected against corrosion.

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

BLAST FREEZING ROOMS

BLAST FREEZING ROOMS 11.2017 BLAST FREEZING ROOMS Applications Berries Poultry Prepared foods Fruits & vegetables Meat Baked goods Mushrooms Fish Seafood Complete solution Quick assembly freezing room Low temperature refrigeration

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Company History Locations Product range References

Company History Locations Product range References Company History Locations Product range References Sirocco 2017 Fact Sheet founded in 1888 as a subsidiary of White, Child & Beney London since 1903 distribution of industrial fans under the brand "SIROCCO"

More information

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by: Johnson Controls - Hitachi Air Conditioning Manufactured by: Johnson Controls-Hitachi Wanbao Air Conditioning (Guangzhou) Co.,Ltd. Address:No.110.ChengAo East Road, Conghua,Guangzhou City, Guangdong Province,China

More information

Guide Specifications

Guide Specifications Guide Specifications Hot Water fired Adsorption Liquid Chillers Bry-Air Adsorption Chiller Overview The chiller shall be a Bry-Air ADC series. The chiller shall consist of a robust, compact, packaged chiller

More information