HEAT TREAT EQUIPMENT Quality Used Heat Treating Equipment Item V-1062 Furnace Super 36 Allcase IQ, 36x72x36
|
|
- Shauna Green
- 5 years ago
- Views:
Transcription
1 Manufacture: Surface Combustion FNC #6487 Type: Super 36 Allcase IQ Furnace Serial No.: BC Max Fuel Demand: Natural Gas CFH Heating Chamber: (4) sets of U-tubes Max Temp: 1950 F Power: 480V, 3-Phase, 60 Hz Working Dim s: 36 wide x 72 deep x 36 high Quench Tank: 5,000 gallon capacity Includes: High flow 25,000 GPM, 30 HP quench agitation system (4) Agitators, 7.5 HP each Two-speed quench agitation 54 KW quench heating for 460V, 160 F operation (6) heaters, 9 KW each Air cooled quench oil cooler for 160 F operation, (1) fan System #1 automatic internal handling (2 HP motors) Heavy duty 5 diameter super alloy rollers and rails located on 21 centers (2) Recirculating cast alloy fans, 5 HP each Vibrating absorbing fan mountings Proof of motion for fans Door opening enlarged 1 at both sides Atmosphere piping for high/low flow endothermic atmosphere to the furnace chamber (high flow during motions) Natural gas enriching gas control valve Waukee Flow meters: (1) each of endo, natural gas, air, ammonia, and nitrogen Automatic nitrogen purge system Office: (734) Fax: (734)
2 Heavy duty refractory insulation with arched roof that promotes atmosphere recirculation 13 ½ wall insulation for reduced heat losses Recuperation & Automatic plunge cooling Time delay for combustion system manual reset shut off valve Two 2 shim stock ports one on each side of the furnace roof drop Controls: Free-standing Nema 12 enclosure, 2-door 72 W x 18D x 72 H, 200 Amp disconnect Honeywell UDC2500 furnace hi-limit Honeywell UDC2500 quench hi-limit Allen Bradley SLC505 processing controller CASEmate Controlle with HMI Monitor (2) SSI Gold probe with Type S T/C for carbon Remote operator control station on quench tank Motors: (1) Combustion air blower, 3 HP (2) Recirculating fans, 5 HP each (1) Rear handler, 2 HP (2) Top cool fans, 2 HP each (4) Agitators, 7.5 HP each (1) Oil recirculating pump, 5 HP (1) Heat exchanger fan, 2 HP This unit is in excellent condition. The hoods, stacks, and vents are also included. Office: (734) Fax: (734)
3 NOTE: equipment is sold AS IS, WHERE IS and buyer shall indemnify seller against and hold seller harmless from any and all claims, actions and damages arising out of the possession, operation, condition or use of the equipment. Seller suggests that you contact the manufacture for important information pertaining to safety and proper use and operation of the above equipment. For safety reasons, we request that you do not place the equipment into service until you have received current safety instructions from the manufacturer. Specifications are taken with care, but are not certified. No warranties or guarantees, written or implied. Office: (734) Fax: (734)
4 Office: (734) Fax: (734)
5 Office: (734) Fax: (734)
6 Office: (734) Fax: (734)
7 Office: (734) Fax: (734)
8 Office: (734) Fax: (734)
9 Office: (734) Fax: (734)
26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace
HEAT TREAT EQUIPMENT USED EQUIPMENT DATA SHEET 26 Mesh Belt Brazing Annealing Furnace Stock #: U-3427 Serial Number: J. L. Becker Company J3454/J3455/J3456 Year Built: 2007 Equipment: The J.L. Becker furnace
More informationThe DWC-Series - Drum Washer / Crusher Unit
The DWC-Series - Drum Washer / Crusher Unit SRS Engineering's drum washing and crushing system (DWC-Series) is designed for applications that require washing of the drums prior to crushing the drums for
More informationSTR-Series Indirect-Fired Air Turnover Units
STR-Series Indirect-Fired Air Turnover Units Equipment Specifi cations 1.800.589.3691 www.weather-rite.com GAS/OIL HEATING ONLY INDIRECT-FIRED AIR TURNOVER UNIT GUIDE SPECIFICATIONS PART 1 GENERAL [Gas][Oil][Gas/Oil
More informationAFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh
WATER HEATERS / BOILERS COWB3 Oil-Fired Hot Water Boiler PRODUCT SPECIFICATIONS Bulletin No. 0654 March 08 Supersedes September 05 AFUE up to 85.% Heating Input 05,000 to 45,000 Btuh MODEL NUMBER IDENTIFICATION
More informationConveyor and Batch Reflow Ovens
Lead Free Soldering Technology Conveyor and Batch Reflow Ovens * LEAD FREE Conveyor Reflow Oven Features: Lead and Lead free Compatible 100% forced air Horizontal Convection TM oven** 3 vertical heating
More informationG315/6 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-6 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationSECTION HEATING BOILERS
SECTION 23 52 00 HEATING BOILERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes boilers, controls and boiler trim, steam and condensate connections, hot water connections, fuel burning system and connections,
More informationG315/5 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G315-5 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationRQE Series Temperature Controllers
RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature
More informationOil & Gas Case History
Unit Type: Air Handling Unit & Compressor Skid (AHU+CSV) Project Name: FGP LER Substation 51 Cooling Duty: No. 2 x 228 kw Site Location: Kazakhstan Year: 2017 End User: TengizChevrOil Manufacture of 2
More information.03 ATMOSPHERIC DEAERATOR
.03 ATMOSPHERIC DEAERATOR SPECIFICATION SHEET NO. 3200 OCTOBER 1, 2007 GENERAL DESCRIPTION The Sellers atmospheric.03 deaerators condition make-up water and condensate returns to convert them into more
More informationDOM-5. Domestic Hot Water Heaters & Boilers
DOM-5 Domestic Hot Water Heaters & Boilers Unlike other manufacturers, which rely solely on achieving high operating efficiency, the Dominator Series is designed for total efficiency based on operating
More informationSENTRA Series Water Unit
SENTRA Series Water Unit Standard Unit: F to 0 F Process Fluid Temperatures* Optional High Temperature Configuration to 0 F Direct Injection Cooling 0 to kw Heaters to 7. HP Centrifugal Pumps (0-00 GPM)
More informationAIR HANDLER SPECIFICATION
AIR HANDLER SPECIFICATION Air Handlers AH-1 through 5 The following air handlers will be supplied: AH-1 FX15-4842 Series 5700 CFM AH-2 FX15-4236 Series 3990 CFM AH-3 FX15-3633 Series 2570 CFM AH-4 FX15-3330
More informationProduct Data BW9 WATER BOILER SERIES B
GAS --- FIRED CONDENSING WATER BOILER SERIES B Product Data Fig. 1 - Model 50-100 Series B Fig. 2 - Model 125-200 Series B C US Use of the AHRI Certified TM Mark indicates a manufacturer s participation
More information30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)
Temperature Control Units Water & Oil - 00 F Portable Chillers Air & Water-Cooled 0-70 F Central Chillers Air & Water-Cooled Packages & Modules 0-70 F Pump Tank Stations Chilled or Tower Water 00-00 gallons
More informationSuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044
SuperOX TM Oxygen Sensor U.S. Patent No. 5,635,044 Operations Manual Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 513-772-0060 800-666-4330 Fax: 513-772-9466 www.supersystems.com Table of
More informationGalvanizing Line with Continuous Anneal Capabilities
Galvanizing Line with Continuous Anneal Capabilities Fueled by Drever International and SMS Group Introduction The Drever annealing furnace installed in the Big River Steel s galvanizing line is designed
More information6K-ENDOFLEX ENDOTHERMIC GAS GENERATOR INSTALLATION AND OPERATION MANUAL A TMOSPHERE E NGINEERING C OMPANY
A TMOSPHERE E NGINEERING C OMPANY Document ID BL-3005-MAN-R1 6K-ENDOFLEX ENDOTHERMIC GAS GENERATOR WITH ENDOINJECTOR AND REACTIONCORE TECHNOLOGY INSTALLATION AND OPERATION MANUAL Phone: 414-331-2457 419
More informationB.C.S. Shop Heaters 26, 30 & 36 (36 shown)
BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass
More informationIndiana WX Oil Furnace Inspection Guide
Indiana WX Oil Furnace Inspection Guide Client: Job # : Address: Phone: Client Interview: Oil Dealer: Date of last service: Comments/Billing information: Standard Inspection / Clean and Tune Follow-up:
More informationNXM2G Installation and Operating Manual
NXM2G-1001 MARCH 26, 2014 NXM2G Installation and Operating Manual (-1 UL version shown) 40VG This manual must be affixed on or adjacent to the boiler or kept with boiler operating manual or other information.
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationADF/ADFH 300 and 500
MODEL ADF/ADFH DIRECT-FIRED SYSTEMS TECHNICAL DATA Four Sizes - 300, 500, 700, 1200 Horizontal Configuration with Full Curb Cap Base Horizontal or Vertical (down) Discharge Indoor/Outdoor Installation
More informationWilliams & Davis Boilers
Williams & Davis Boilers Established 1921 3-Pass Dry-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000D Standard Features
More information5. CONDENSATE PUMPS/UNITS
INDEX Condensate Systems/Pumps GENERAL INFORMATION BURKS PARTS I&O MANUALS. CONDENSATE PUMPS/UNITS PUMP TYPES: GV GV6 USA: (937) 778-8947 Canada: (90) 47-6223 International: (937) 61-398 A 7/1 Condensate
More informationG515/7 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview Engineering Specifications There shall be provided and installed G515-7 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing with
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More information(2) 325 tpd York Chlorine Liquefier Systems
(2) 325 tpd York Chlorine Liquefier Systems The liquefier is a split bundle and serves as both the primary liquefier and the secondary liquefier. The total for each York system is 325 tons liquid Cl2,
More informationPower Flame Incorporated
Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,
More informationMDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.
3913017 03.15 Submittal Data MDVS 250-500 Tag: DF-1, DF-2 Job Name: Parkside Memory Cottage ALF Representative: Tom Barrow Company Job Location: Port Charlotte, FL Job #: 80036 Architect/Engineer: Contractor:
More informationThis series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.
The SRV-Series is designed for system sizes handling 25-250 gallons per hour and is the simplest and highest performance system design in its price range. It is composed of a non-scraped vessel with a
More informationCR Series Command Relays
CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for
More informationG615/11 Cast Iron Boiler
Engineering Submittal Sheet Boiler Overview LISTED Engineering Specifications There shall be provided and installed G615-11 Buderus sectional cast iron hot water boiler(s), suitable for forced draft firing
More informationA. Section Common Motor Requirements for HVAC Equipment: Fan motors.
SECTION 235533 - FUEL-FIRED UNIT HEATERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Gas fired unit heaters. B. Oil fired unit heaters. C. Tubular infrared heaters. 1.2 RELATED REQUIREMENTS A. Section 230513
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationCopper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving
Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters Low NOx, Quiet, Efficient, Space-Saving Mighty Therm Lo-NOx Greater energy efficiencies as high as 84% are achieved through
More informationLong lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction.
BANANZA 100% Thermal Efficient, Direct-Fired, Make-up Air Systems For Ventilation, Heating and Curing in Paint Booths and Finishing Areas SPRAY-CURE B-Series Helps reduce cycle time and increase productivity
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationConcrete Applications
Concrete Applications Sioux Industrial Water Heaters Sioux has been a leading supplier of water heaters to the concrete industry since the 1960s. Sioux offers standard units for any size operation, ranging
More informationSSi SUPER SYSTEMS INC. PROBE CONDITIONING SYSTEM- P/N FOR GENERATOR SAMPLING SYSTEMS ACTUATED BY AC20 INSTRUCTION MANUAL M4515.
April 12, 2005 PROBE CONDITIONING SYSTEM- P/N 13036 FOR GENERATOR SAMPLING SYSTEMS ACTUATED BY AC20 INSTRUCTION MANUAL M4515 SSi SUPER SYSTEMS INC. 7205 Edington Drive Cincinnati, Ohio 45249 1-513- 772-0060
More informationDesign Benefits and Advantages:
The SRH-Series is designed for system sizes handling 25-250 gallons per hour and features scrapers and immersion heaters in a large capacity oil bath. The system incorporates a self adjusting scraper unit
More informationBURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM
BURNERS/ FLARES VAREC BIOGAS 4W Series WASTE GAS BURNER & IGNITION SYSTEM The Varec Biogas 4W Series Waste Gas Burner is a highly reliable flare and ignition system ideal for use in burning excess biogas.
More informationGB Condensing Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB162/100 wall-hung condensing hot water boiler(s), suitable for
More informationEffective october 14, 2014
COS-101 & COS-101S COMBI OVEN STEAMER REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items
More informationModel R060 Installation - Operation Manual
Residential Heat Pump Water Heaters Model R060 Installation - Operation Manual Important Note Read this entire manual before beginning installation Manufactured By: 6670-A Corners Industrial Court Norcross,
More informationGH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM
GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM The GH Series The GH is Carver s horizontal, end suction pump series for handling water, oils, and chemicals in marine, process, and general
More informationThermal Devices, Inc. Mount Airy, Maryland USA
Unit Heater 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Wall or Ceiling Mounted Canadian Standards Standards Description The Chromalox self-contained blower heater provides
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationHCLEARFIRE. High-efficiency, modular steam boiler HP
HCLEARFIRE High-efficiency, modular steam boiler 10-60 HP High-Efficiency, Low-Emission Steam Boiler in a Compact Footprint The ClearFire -H compact, gas-fired horizontal boiler is designed specifically
More informationPROBATCH MODEL H. Optimize Your Polymer Performance
The ProBatch H dry polymer feed system precisely meters and mixes dry polymer with water to form a homogenous, fully activated polymer solution. The modular system design is fully assembled and factory
More informationINFRARED RADIANT HEATERS
IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationUpflow/Downflow Horizontal Right or Left Gas-Fired Furnace
Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace XT 80 TUDA00A9H2B, TUDB060A9H3B TUDB080A9H3B, TUDC080A9HB TUDB00A9H3B, TUDC00A9H5B TUDDA9H5B, TUDD0A9H5B TDDB060A9H3B, TDDB080A9H3B TDDC00A9H5B,
More informationCLIMATE CONTROL PRODUCT GUIDE
CLIMATE CONTROL PRODUCT GUIDE 0985822 Climate Control Product Guide 3/08-25M CURE THAW PREVENT FROST AIR HEAT DRY TABLE OF CONTENTS 2 3 GROUND HEATERS HEATING AND DRYING Ground Heaters is a brand of climate
More informationUS Filtermaxx. 200,000 BTU Waste Oil Burner
US Filtermaxx 200,000 BTU Waste Oil Burner Assemble the Burner: Remove all the parts from the box. Locate the burner flange coupling and attach it to the front of the burner as seen in the photo below
More informationSN Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH
TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationGB Condensing Gas Boiler
Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus GB142/45 wall-hung condensing hot water boiler(s), suitable for induced
More informationBurner Comparisons. Typical Competitor s Burner
Burner Comparisons INOV8 s Typical Competitor s Burner Automatic nozzle cleanout Yes No Available BTUs rated as input 100,000 to 1,000,000 76,500 to 500,000 Burner Motor - hp 1/5 1/7 Combustion safety
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationFEATURES AND BENEFITS
FEATURES AND BENEFITS Product Features and Benefits Full Product Line Offering Feature All models are 80% thermally efficient Blower performance up to 3.0 W.C. DX or chilled water section with factory
More informationVF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual
342 N. Co. Rd. 400 East Valparaiso, IN 46383 888-432-8924 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. VF/VG700 Jumbo Construction
More informationEffective october 14, 2014
COS-20G combi oven-steamer REPLACEMENT PARTS LIST Effective october 14, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationhinged tops or hinged doors.
With a Cyber-Jet conveyorized parts washer you get quality, elegance, and flexibility. Three(3) module C-14 system ( wide conveyor belt) Typical of C-24, C-36, and C-48 systems (,, wide conveyor belts)
More informationProudly assembled in U.S.A
s HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb Proudly assembled in U.S.A Up to 85% thermal efficiency! Raypak s Decades of expertise and technological innovations went into creating
More informationRental Boiler Specifications (Nebraska Boiler)
Rental Boiler Specifications (Nebraska Boiler) ESI's 72,000 pph trailer-mounted watertube steam boilers are designed and built in accordance with ASME Code. Each boiler is arranged for natural gas or #2
More information92831 TEL: (714) FAX:
Document No. 1800-11 High-Performance Vacuum/Nitrogen Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton,
More informationRev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4
More informationIndustrial Applications
Industrial Applications Sioux Industrial Water Heaters Sioux has been a leading supplier of industrial water heaters since the 1960s. Sioux offers standard units ranging from 415,000 BTUs to 6,000,000
More informationUW50 UTENSIL/PAN WASHER
Item # Quantity C.S.I. Section 11400 UW50 STANDARD FEATURES 2.1 gallons of water per rack (booster equipped models) 19 racks per hour Timed wash cycles for 2, 4 or 6 minutes Stainless steel tank, tank
More informationRotary Metal Parts Treatment System; Rotary Metal Parts Treater RMPT Effluent Heater MPT Quench Tower Rotary Metal Parts Treater
1 1 1 1 1 1 1 1 0 1 Rotary Metal Parts Treatment System; Rotary Metal Parts Treater (00-MPT-1), RMPT Effluent Heater (00-HEAT-1), and MPT Quench Tower (00-TOWR-1). There will be one Rotary Metal Parts
More informationSIOUX Water Heaters SIOUX WATER HEATERS. Hybrid Water Heater PWP Water Heater M-1
SIOUX Water Heaters SIOUX WATER HEATERS Hybrid Water Heater PWP-1000 Water Heater M-1 Sioux Industrial Water Heaters Sioux has been the number one supplier of water heaters to the concrete industry since
More informationMD-170 Installation/Operator's Manual
MD-170 Installation/Operator's Manual DATE OF PURCHASE DISTRIBUTORS NAME MODEL NO. MD-170 Serial Number(s) Table of Contents 3 4 5 Maximum Capacity (Dry Weight) 170 lbs. 77.1 kg Basket Diameter 51-1/2"
More informationREFRIGERATION PRODUCTS
REFRIGERATION PRODUCTS Product Catalog REFRIGERATION PRODUCTS PAUL MUELLER COMPANY Table of Contents 3 x 5 Falling Film Chiller.................................... 1 4 x 8 Falling Film Chiller...................................
More informationCNA-Series - Large Industrial Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to
More informationTECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS
TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM
More informationPortable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions
Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop
More informationLOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS
FTIIC-6 LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS Futera II Series boilers and water heaters are also available with corrosion-resistant, brushed stainless steel jacket. Ideal
More informationWilliams & Davis Boilers
Williams & Davis Boilers Established 1921 3-Pass Water-Back Scotch Marine Boiler SIZES 15HP THROUGH 1500HP GAS, OIL OR COMBINATION BURNER FIRETUBE HOT WATER & PRESSURE STEAM BOILERS 3000W Standard Features
More informationService Parts, Kits and Accessories
The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components
More informationExplosion-Proof Forced Air Unit Heater - XGB
Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions.
More informationProduct Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES
Product Data Model BW9 Gas-Fired Condensing Water Boiler Series A best way to obtain plenty of clean combustion air. The induced draft fan draws in the outside combustion air, then takes the cooler flue
More informationMODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS
MODEL ADF/ADFH 300 and 500 FOR INDUSTRIAL & COMMERCIAL APPLICATIONS Model ADF CSA 3.7 ANSI Z83.4 Non-Recirculating Industrial Air Heaters WARNING: GAS-FIRED APPLIANCES ARE NOT DESIGNED FOR USE IN HAZARDOUS
More informationIndustrial Air Heaters
HVH Horizontal or Vertical Discharge Fan Forced Unit Heater Industrial Air Heaters 2.6-50 kw 8,900 170,600 Btuh 208, 240, 277, 480, and 600 volt 1 or 3 phase Vertical or Horizontal Airflow Wall or Ceiling
More information2010 USA PRICE LIST.
2010 USA PRICE LIST STOVE BUILDER INTERNATIONAL INC. (SBI) 1700, Leon-Harmel Quebec City, Qc, Canada G1N 4R9 Tel. (418) 780-2332 Fax (888) 286-1418 ITO PLACE AN ORDER TO PLACE AN ORDER PURCHASE ORDERS
More informationPulse Firing Doubles Capacity and Cuts Fuel Costs
Honeywell Combustion Safety 11699 Brookpark Road Cleveland, Ohio 44130 www.combustionsafety.com Pulse Firing Doubles Capacity and Cuts Fuel Costs Why Pulse Fire? Many industrial manufacturing leaders are
More informationGas and Electric Convection Ovens
Gas and Electric Convection Ovens TURBO-FLOW TURBO-FLOW TURBO-FLOW TURBO-FLOW Door enhancements have increased the durability of the door mechanisms Dual-open doors one hand opens and closes both doors
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationBy Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
More informationLEAD RECYCLING PLANT. Battery Machine Manufacturers: Since 1989
Battery Machine Manufacturers: Since 1989 LEAD RECYCLING PLANT We provide TURNKEY SOLUTIONS for used lead-acid battery recycling that includes, Project Feasibility studies, Specification developments,
More informationLQ AQ SQ. Air-cooled and water-cooled portable chillers
LQ AQ SQ Air-cooled and water-cooled portable chillers Choose from a complete line of dependable Accuchiller portable chillers LQ Series AQ Series SQ Series No other manufacturer can offer you a larger
More informationEBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...
Installation & Operating Manual EBC 10 Fan Control USA CAN Product Information... Chapter 1+2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter
More informationInstruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANAUL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationControllers. Instruction Manual WARNING
Controllers Instruction Manual WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING OR SERVICING THIS PRODUCT. Like any piece of
More informationKeltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions
36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual
More informationOPERATING MANUAL 12 AXIAL FANS
Manual No. BLWR051 Rev. 0 April 2015 OPERATING MANUAL 12 AXIAL FANS MODELS: CVF-12AC CVF12CAN15 CVF12CAN25 Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967
More informationLAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters
LAARS MIGHTY THERM High Efficiency Boilers and Volume Water Heaters The Ideal Replacement Boiler % Thermal Efficiency Straight Forward, Easy to Use Controls - 000 MBH s Industry Leading Low NOx, ppm Indoor/Outdoor
More informationRefer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents
TABLE OF CONTENTS A complete line of commercial, industrial, and residential heating equipment is offered. This catalog describes in detail the gas-fired, gravity and power vented, commercial/ industrial
More informationAqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND
Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating
More information