Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Size: px
Start display at page:

Download "Hygro and hygrothermo transducers (capacitive) for HVAC monitoring"

Transcription

1 Data Sheet Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special miniature rod version for OEM applications with current or voltage outputs These humidity transducers have been especially developed for HVAC applications and are characterized by their outstanding long-term stability, high measuring accuracy, excellent high-humidity response and good chemical resistance. Attractively designed cases as wall or duct models for indoor use, and as miniature rod models, can optimally handle almost any air-conditioning task. Transducers for humidity, as well as combined instruments for humidity and temperature with current or voltage outputs are available. Applications include the complete air conditioning and ventilation sector in domestic and office buildings, as well as in storage areas and greenhouses. For the especially high requirements of indoor swimming pools and stables, transducers in version A have proved particularly successful, in addition to achieving excellent measurement results in metereology. Furthermore, the special rod model is available for integrating humidity measurement into existing systems where space is tight, thus making it particularly suitable for OEM applications. Technical data Humidity sensor Humidity range Humidity working ranges Humidity accuracy at 20 C capacitive, condensation permitted 0 100% rh 10 90% rh: indoor version 20 90% rh: wall and duct version (version B); rod version 0 100% rh: wall and duct version (version A) ± 3% rh: indoor version with voltage output ± 3% rh: indoor version with current output; wall and duct version (version B) within humidity range 40 60% rh ± 5% rh: indoor version with current output; wall and duct version (version B) in remaining damp area ± 3% rh: rod version at 54% rh ± 5% rh: rod version in remaining damp area ± 2% rh: wall and duct version (version A) in damp area 0 90% rh ± 3% rh: wall and duct version (version A) in remaining damp area Temperature error at 45% rh typically -0.05% rh / C Temperature sensor platinum-chip temperature sensor Pt1000 to EN , tolerance class A Temperature ranges 0 to +50 C: indoor version; wall and duct version (version B) -20 to +80 C: wall and duct version (version A) -40 to +60 C: rod version Temperature accuracy at 20 C ± 0.3 C: indoor version: voltage output; wall and duct version (version A) ± 0.5 C: indoor version: current output; wall and duct version (version B); rod version Output signals 4 20mA, 0 1V, 0 5V, 0 10V (instrument version according to order code)

2 Data Sheet Page 2/6 Supply 15 35V DC; 24V AC ± 20%: instruments with voltage output 20 28V DC: instruments with current output V DC: only for rod version Electromagnetic compatibility to EN and EN Case ABS plastic for indoor version PC plastic with wall, duct and rod version Protection IP20: indoor version IP40: wall and duct version (version B) IP65: wall and duct version (version A); rod version Load resistance R L 500 Ohm max. for current output Current 20mA max., 5mA for rod version Ambient temperature - 5 to +50 C: indoor, wall and duct version (version B) -20 to +50 C (sensor head +80 C): wall and duct version (version A) -20 to +60 C: rod version Storage temperature -30 to +60 C Weight approx. 100g for indoor version approx. 150g for wall version approx. 250g for duct version approx. 50g for rod version Accessories Dust filter Membrane filter (standard) for low-level contamination in the HVAC area (indoor application) Sintered bronze filter for mechanical loads and very dusty atmospheres Sintered stainless steel filter extremely effective with mechanical and thermal loads, as well as with corrosive media Metal mesh filter for high humidity, risk of condensation or rapidly changing humidity cycles Humidity sensors Temperature sensor Humidity sensor checks Type: HC 101 for rod version nominal capacity 200 ± 20pF operating temperature -40 to +120 C Type: HC 200 for wall and duct versions (version B) nominal capacity 200 ± 20pF operating temperature -40 to +110 C Type: HC 1000 for indoor, wall and duct versions (version A) nominal capacity 500 ± 50pF operating temperature -40 to +120 C platinum-chip temperature sensor made in thin-film technology to EN , tolerance class A nominal value 1000 Ohm at 0 C dimensions in mm (W x L x H) 2.0 x 5.0 x 1.3 temperature range -50 to +400 C Humidity sensor checks can be carried out, to check the accuracy of humidity transducers. The checking procedure is described in detail in DIN , IEC Publication 260, ISO/R The underlying principle is that a certain climate forms in the air above an aqueous, saturated salt solution. Sensor check sets with values of 33%, 55% and 76% rh are available from stock.

3 Data Sheet Page 3/6 Dimensions Indoor version Type /10 Wall version Type /20 Type /21 Duct version Type /30 Type /31 Rod version Type /40 Measurements in mm.

4 Data Sheet Page 4/6 Connection diagram Indoor version Type /10 Wall/duct version Type /20, Type /21, Type /30, Type /31 Rod version Type /40

5 Data Sheet Page 5/6 Order details: Hygro and hygrothermo transducers (capacitive) for HVAC monitoring (1) Basic version /10 Hygro/hygrothermo transducer, indoor version /20 Hygro/hygrothermo transducer, wall version (version A) /21 Hygro/hygrothermo transducer, wall version (version B) /30 Hygro/hygrothermo transducer, duct version (version A) /31 Hygro/hygrothermo transducer, duct version (version B) /40 Hygro/hygrothermo transducer, rod version (2) Hygro/hygrothermo transducer X X X X X X 1 Humidity X X X X X X 2 Humidity and temperature 1 (3) Ranges X % rh; 0 to +50 C X X % rh; 0 to +50 C X X % rh; -20 to +80 C X % rh; -40 to +60 C (4) Output signals X X X X X mA X X X V X X V X X X X X V (1) (2) (3) (4) Order code Order example / Please take note of the humidity working ranges under Technical Data! Stock versions: (1) (2) (3) (4) Sales No / / / / / / / / / / / / / / / / / / / / / / / /

6 Data Sheet Page 6/6 Order details: Accessories (1) Basic version /90 Filter /91 Humidity sensors, capacitive /92 Temperature sensor /93 Humidity sensor check sets (2) Filter X 801 Membrane filter (standard) X 802 Sintered bronze filter X 803 Sintered stainless steel filter X 804 Metal mesh filter (2) Humidity sensors X 806 HC 1000 X 807 HC 200 X 808 HC 101 (2) Temperature sensor X 005 Pt 1000 (2) Humidity sensor checks X % rh magnesium chloride X % rh magnesium nitrate X % rh sodium chloride (1) (2) Order code - Order example / Stock versions (1) (2) Sales No / / / / / / / / / / / / / / / / / / / / / /

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration

More information

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring Data Sheet 907021 Page 1/9 Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring For measuring relative air humidity, temperature, and fresh

More information

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications Data sheet 907020 Page 1/7 Hygro and Hygrothermo Transducers (capacitive) for climatic applications To measure relative humidity and temperature For versatile climatic applications and ventilation For

More information

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications Data Sheet 907020 Page 1/9 Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications For measuring relative humidity and temperature For versatile climatic applications and ventilation

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 90.7031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 907031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH HT-1300 Series Temperature and Humidity Duct Sensor Product Bulletin Specifically designed for HVAC application, the HT-130x-UD1 sensor is a highly accurate and reliable for measuring relative air humidity

More information

Hygrostats (hygrometric)

Hygrostats (hygrometric) Data Sheet 907032 Page 1/6 Hygrostats (hygrometric) For easy 2-state control of relative air humidity For indoor and air duct mounting With potential-free change-over contact(s) No voltage supply required

More information

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature 1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and

More information

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection. Features Humidity and Temperature outputs in same unit With or without display Humidity output 0-10 Vdc or 4-20 ma Temperature output 0-10 Vdc or 4-20 ma As option passive direct temperature output PT1000,

More information

DP 300 mobile dew point instrument

DP 300 mobile dew point instrument Instruction manual DP 300 mobile dew point instrument For measuring pressure, dew point and atmospheric dew point in different applications: Compressed air plants (refrigeration/ adsorption dryer) Granulate

More information

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering Duct Humidity and Temperature Transmitter DHT Apr. 17 Features Humidity and Temperature outputs in same unit Humidity output 0-10 Vdc or 4-20 ma Temperature output 0-10 Vdc or 4-20 ma As option passive

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature 1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and

More information

Relative Humidity Transmitters

Relative Humidity Transmitters Relative Humidity Transmitters Standard Accuracy Series 730,732, ± 2% RH or Low Cost 733 and 734 Design ± 3 % RH Analog : 2-Wire (4-20mA) or User-Selectable (0-1V, 0-5V, 0-10V or 0-1mA) CE-approval TYPICAL

More information

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes. Series Humidity / Temperature Transmitter for Industriell Applications Calculation of Dew Point and Frost Point Temperature The series stands for multifunctionality, highest accuracy, easy mounting and

More information

for relative humidity and temperature

for relative humidity and temperature 1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the

More information

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2 Sensors and switches Temperature, Pressure, Humidity, Air flow, CO 2, CO and NO 2 Regin sensors and switches Comfortable and economic indoor climate To measure is to know. Temperature, carbon dioxide,

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Product data sheet AIRWIN BO-FK-120J Humidity sensors Product data sheet AIRWIN BO-FK-120J The room humidity sensor BO-FK-120-J is used in offices and computer rooms to measure the relative air humidity. Other fields of application for BO-FK-120J are the

More information

for relative humidity and temperature with calibration certificates

for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 QFA4160 AQF4150 Symaro Room Sensor for relative humidity and temperature with calibration certificates QFA4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level Sensor EK-L CSM_EK-L_DS_E_4_ Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to 11 mm or 1 to mm Built-in

More information

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet FTK+ Duct sensor for humidity and temperature Datasheet Subject to technical alteration Issue date: 03.04.2018 A002 Application Duct humidity and temperature sensor in new hinged lid enclosure USE for

More information

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Instruction manual Hygrothermo transmitter THD-500 Series No.THD51E1 2001.11 To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual. Notes This

More information

Duct Humidity/Temp Sensor

Duct Humidity/Temp Sensor Duct Humidity/Temp Sensor Model HU-226 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from

More information

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range Moisture Sensors DP & Rh The basic low cost solution With a wide range Moisture technologies and their ranges DEW-POINT SENSOR TRAINING No single technology can cover the entire range All have limitations

More information

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g. INSTRUCTION MANUAL FA 400 Humidity measuring instruments with display and alarm for measurement of the pressure dew point and the atmospheric dew point in different applications: - compressed air plants

More information

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE: The RO120 is a precision transmitter that provides quick and accurate humidity, barometric pressure, temperature, absolute pressure and dew point measurements in a wide range of applications. It has a

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Outside Air Humidity & Temperature Sensor

Outside Air Humidity & Temperature Sensor Outside Air Humidity & Temperature Sensor RoHS Model HU-227 Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

SITRANS F M MAG 3100 P:

SITRANS F M MAG 3100 P: Dedicated for the chemical industry SITRANS F M MAG 3100 P: The electromagnetic flowmeter solution with devoted features. Process Instrumentation usa.siemens.com/mag The best choice for the chemical industry

More information

HYGROMER MP 100 A Meteorology probe

HYGROMER MP 100 A Meteorology probe HYGROMER MP 100 A Meteorology probe Bedienungsanleitung Mode d emploi Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 100A for measuring humidity and temperature, you have

More information

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Connection. e. g. Pt100. reference limit. yellow Output I. Composition Trip amplifiers for Pt1, Ni1 KFD2GREx1 Connection e. g. Pt1 Input EEx ia IIC 1+ 2 3 Hazardous area 1channel Input EEx ia IIC 2 switching points operate on 2 output relays High/low alarm can be selected

More information

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output

More information

Condensation drying for industry and trade

Condensation drying for industry and trade Air dehumidifying 2011 Condensation drying for industry and trade Condensation drying for industry and trade 2011 DH 18 domestic dehumidifiers Development, production and sales: All from a single source

More information

Room Humidity/Temp Sensor

Room Humidity/Temp Sensor Room Humidity/Temp Sensor Model HU-225-EU (Not Available in North America) RoHS Ultra fast response cross-linked bulk polymer...capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter

More information

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma

More information

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield. Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity

More information

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY > Mechanical > Electronic > Guards PRODUCT RANGE 2017 FÜHLBARE PRÄZISION HYGRASREG MECHANICAL For use in dust-free, non-polluted and non-aggressive air HYGRASREG

More information

HUM-M2 Humidity Sensor Module Description

HUM-M2 Humidity Sensor Module Description HUM-M2 Humidity Sensor Module Description Humidity Sensor Modules are designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used for

More information

Potential Applications

Potential Applications HIH-4602-L HIH-4602 Series monolithic IC humidity sensor with integral precision RTD in TO-39 Features Linear voltage output vs %RH Laser-trimmed interchangeability Chemically resistant Enhanced accuracy,

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

Selecting the right humidity sensor for your application

Selecting the right humidity sensor for your application Selecting the right humidity sensor for your application Humidity is the presence of water in the air. The amount of vapour can affect human comfort as well as many manufacturing processes. Monitoring

More information

Measurement and Control Technology

Measurement and Control Technology Measurement and Control Technology Keep a firm grip on temperature and humidity Complete solutions for indoor temperature Humidification and evaporative cooling Humidity and Temperature Sensors Sensors

More information

Digital Salt / TDS Meter. 390a. The Value Leader TM

Digital Salt / TDS Meter. 390a. The Value Leader TM Digital Salt / TDS Meter 390a The Value Leader TM www.tpi-thevalueleader.com Contents Before Use... 1 Description... 1 Applications... 1 Precautions... 2 Overview... 3 Functions... 4 LCD Symbols... 5 Specifications...

More information

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - wwwmytubcouk - info@mytubcouk 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Use Operating voltage

More information

HYGROMER - MP 400 A Meteorology probe

HYGROMER - MP 400 A Meteorology probe HYGROMER - MP 400 A Meteorology probe Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 400A for measuring humidity and temperature, you have purchased a precision measuring

More information

Product data sheet AIRWIN BO-120 Hygrostats

Product data sheet AIRWIN BO-120 Hygrostats Product data sheet AIRWIN BO-120 The room hygrostat BO-120 is used as two-point controller in climate cabinets, as well as for humidifiers in offices and computer rooms to control the relative humidity.

More information

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 1859P04 QFM41.. AQF4150 AQF3153 Symaro Duct sensors for relative humidity and temperature with calibration certificates QFM41.. Operating voltage AC 24 V / DC 13.5...35 V Signal output

More information

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats

More information

GMH 285 / GMH 285-BNC

GMH 285 / GMH 285-BNC GMH 285 GMH 285-BNC H69.0.01.6C-02 Operating Manual Pt1000 Precision Thermometer For exchangeable probes, with alarm as of version V1.0 GMH 285 / GMH 285-BNC GMH-GREISINGER GMH-GREISINGER WEEE-Reg.-Nr.

More information

Model 5190-F Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

More information

MP 601A Humidity Probe INSTRUCTION MANUAL

MP 601A Humidity Probe INSTRUCTION MANUAL MP 601A Humidity Probe INSTRUCTION MANUAL CONTENTS DESCRIPTION... 3 OPERATION... 3 WIRING... 5 INSTALLATION... 7 MAINTENANCE...7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 9 SPECIFICATIONS... 11

More information

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10

More information

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the Model 1500 Portable Chilled Mirror Hygrometer APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

WIO200 Water In Oil measuring instrument

WIO200 Water In Oil measuring instrument WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at

More information

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control: 7 711 Flame detector QRA4.U UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate

More information

Introduction to humidistats

Introduction to humidistats P 8/8 Introduction to humidistats technology J.Jumeau 20121030 P 1/4 Some humidity measurement devices, 18eme Century (Ultimheat collection) Relative humidity control is relatively new, and the first mechanical

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy

More information

THERMASREG TR 040 THERMASREG TR 060

THERMASREG TR 040 THERMASREG TR 060 THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary

More information

Accessories, interfaces, sensors and complete solutions.

Accessories, interfaces, sensors and complete solutions. 101101_DSsensors_EN Accessories, interfaces, sensors and complete solutions. Overview Boomerang is much more than just another temperature log system. Boomerang is a versatile and flexible monitoring and

More information

Duct Temperature Sensors

Duct Temperature Sensors 1 762 1761P03 1762P01 Mounting flange AQM630 QAM21 Symaro Duct Temperature Sensors QAM2161040 QAM2171040 Active sensors for acquiring the air temperature in air ducts AC 24 V or DC 13535 V Signal output

More information

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications MEAS 5700 Subermsible Liquid Level Pressure Transducer Features Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.25% Accuracy

More information

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION... 3 OPERATION... 4 MEASUREMENT... 5 MAINTENANCE... 7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 10 SPECIFICATIONS...

More information

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids

More information

U5300 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.1% Accuracy ±0.5% Total Error Band Compact Outline -40 C to +125 C

More information

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products 1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On

More information

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits Characteristics analog input module - 16 inputs - thermocouple - 16 bits Product availability : Stock - Normally stocked in distribution facility Price* : 5684.45 USD Main Range of product Product or component

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Are Thermistors the Right Choice for Your Temperature Measurement Application?

Are Thermistors the Right Choice for Your Temperature Measurement Application? Are Thermistors the Right Choice for Your Temperature Measurement Application? A Primer on Thermistor Technology Hampton VA., June 8, 2008 There are numerous technologies available to measure temperature

More information

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1 emperature Multi-Input Device for Cabinet Installation Features Assembly For 8 temperature or analog sensors Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Room Temperature Sensors

Room Temperature Sensors 1 749 1749P01 QAA201 Symaro Room Temperature Sensors QAA201 Active sensors for acquiring the room temperature Operating voltage AC 24 V or DC 135 35 V Signal output DC 010 V or 420 ma Use In heating, ventilation

More information

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Flame detector. Building Technologies Division Infrastructure & Cities Sector 7 711 Flame detector QRA4 UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4... and this Data Sheet are intended for use by OEMs which integrate

More information

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed

More information

FAST RESPONSE TEMPERATURE SENSORS 42.11a

FAST RESPONSE TEMPERATURE SENSORS 42.11a FAST RESPONSE TEMPERATURE SENSORS 42.11a DESCRIPTION AND APPLICATION These resistance-type sensors are intended for contact temperature measurements of liquid and gaseous substances. The sensor consists

More information

Duct Temperature Sensors

Duct Temperature Sensors Duct s Model TE-701 / 702 RoHS More than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs are available for universal compatibility. Five installation options probe

More information

LOW PRESSURE Intrinsically Safe Transducer AST44LP

LOW PRESSURE Intrinsically Safe Transducer AST44LP Intrinsically Safe Transducer AST44LP Overview The AST44LP is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and the best price-toperformance ratio in

More information

Snifter ATEX22 VERSION. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5

More information

INTERNAL STIRRING CF LIQUIDS

INTERNAL STIRRING CF LIQUIDS A, INTERNAL STIRRING CF LIQUIDS (1) Magnetic Stirrer for an Evacuated Sorption Apparatus (2) Magnetic Stirrer for Use in the Cup Type of Moisture-Transfusion Apparatus 1941 I. \"? ' R FEB 11 1955 UNITED

More information

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products 7 711 Flame Detector QRA4.U Flame detector for use with burner controls from for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate the flame

More information

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks.

Light is simple Compact Monsun The LED damp-proof luminaire range for challenging lighting tasks. www.osram.com/lightingsolutions Light is simple The LED damp-proof luminaire range for challenging lighting tasks. Light is OSRAM Product Efficient in diverse situations is the tried-and-true range of

More information

MELA Sensortechnik GmbH

MELA Sensortechnik GmbH Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH Rivenditore: TERSID Srl Via Demostene,15 128 Milano Tel. 02/27001002 Fax 02/2575313 Mail: tersid@tersid.it Sito web: www.tersid.it sensors -

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control: 7 711 Flame detector QRA4.U UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4.U and this Data Sheet are intended for use by OEMs which integrate

More information

Model 5190-E Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe Model 5190-E Temperature/Humidity Probe User s Manual Rev. D All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2010, All Weather, Inc. All Rights

More information

Sitron s CF Line of Flow Switch Monitors

Sitron s CF Line of Flow Switch Monitors Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,

More information

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and

More information

UDC100 Universal Digital Controller Specifications

UDC100 Universal Digital Controller Specifications UDC100 Universal Digital Controller Specifications 51-52-03-29 November 1999 Overview The UDC100 Universal Digital Controller is a microprocessor-based 1/4 DIN low cost temperature controller. It combines

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Reproducible Climate...

Reproducible Climate... Reproducible Climate...... the new standard in test technology Temperature and Climatic Test Chambers VT 3 & VC 3 Reliable test results... Your adviser for environmental test technology... Characteristics,

More information

Complete packages with Software and Controller

Complete packages with Software and Controller Thermoguard Basic Complete packages with Software and Controller Thermoguard Basic packages contain the software, one sensorcontroller and one sensor. The functional scope of the Thermoguard Basic software

More information

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400 Pressure Transducer / Transmitter AST4400 Overview The AST4400 is a stainless steel pressure transducer with a wide variety of options. With its rugged construction and best price-toperformance ratio in

More information

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

U5600. Wireless Pressure Transducer SPECIFICATIONS

U5600. Wireless Pressure Transducer SPECIFICATIONS SPECIFICATIONS Enhanced Pressure Accuracy Digital 24-bit ADC Output, I 2 C Protocol Wireless Bluetooth 4.0 Connection CE Compliant with Variety of Pressure Ports Compact and Battery Powered [CR2050] Optional

More information

Sintrol Snifter A1+ Manual. Version 1.2.2

Sintrol Snifter A1+ Manual. Version 1.2.2 Sintrol Snifter A1+ Manual Version 1.2.2 Table of Contents 1 INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2 INSTALLATION... 4 2.1 Selecting the installation location...

More information

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE TEMPERATURE AND HUMIDITY MODULE Compliant with RoHS recommendations Based on the rugged HS1101LF humidity sensor, HTF3000LF PVH-3.3 is a dedicated humidity and temperature transducer designed for OEM applications

More information