MP 601A Humidity Probe INSTRUCTION MANUAL

Size: px
Start display at page:

Download "MP 601A Humidity Probe INSTRUCTION MANUAL"

Transcription

1 MP 601A Humidity Probe INSTRUCTION MANUAL

2 CONTENTS DESCRIPTION... 3 OPERATION... 3 WIRING... 5 INSTALLATION... 7 MAINTENANCE...7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 9 SPECIFICATIONS PLEASE, READ THIS FIRST Check the product for any physical damage that may have occurred during shipment. We carefully pack and routinely insure all shipments. If any damage has occurred, it is your responsibility to file a claim with the carrier, prior to returning the damaged product. Please note that our warranty does not cover damage during shipment. Prior to installation, get fully familiarized with important information provided in this manual such as: supply voltage, electrical connections, adjustments, operating limits. A label located on the barrel of the probe provides the main technical data. Do not unnecessarily remove the sensor protection (slotted cap or dust filter) from the probe. Both sensors (humidity and temperature) can be mechanically damaged by careless removal of the protection. The ROTRONIC HYGROMER humidity sensor looks like a small white paper tag. Do not remove from the probe! Each ROTRONIC instrument is carefully checked before shipment. If you have any question or problem, please call our service department at 631/ and press 5 (or ask for extension 21).

3 -3- DESCRIPTION The MP601A is an OEM humidity probe designed primarily for manufacturers of meteorological systems. Operation from a DC voltage and low power consumption make the MP601A particularly suitable for integration with data acquisition systems that operate at remote locations. The probe provides a linear 0..1V output signal that corresponds to %RH. Energizing of the probe is required for only 0.25 seconds during each measurement. Use of the HYGROMER C94 humidity sensor results in exceptional resistance to contaminants. The MP601A can be used over long periods of time without any maintenance or recalibration. The HYGROMER C94 sensor maintains its accuracy over the full range of humidity, even at conditions close to condensation. The MP601A features electronic temperature compensation of the humidity sensor. The probe is equipped with an NTC temperature sensor that is used exclusively to provide data to the temperature compensation circuit. Separate power and signal grounds permit use of a long length of cable without loss of signal accuracy. The sensor bulkhead of the MP601A has two spare pins that can be used to attach a temperature sensor such as a thermistor or an RTD (2-, 3- or 4-wire connection). OPERATION 1. Power Supply The MP601A accepts an unregulated supply voltage between 4.8 and 30.0 VDC. The maximum current consumption is 2.5 ma. The MP601A does not have to be continuously energized. Measurements require that the probe be energized for 0.25 seconds after which the power can be turned off to conserve energy. 2. Output Signal The MP601A provides one linearized voltage output signal corresponding to relative humidity: VDC = 0 to 100%RH Do not connect a load to the output with an impedance of less than 1000 Ω.

4 -4- IMPORTANT: At all temperatures, the relative humidity signal is referenced to the saturation vapor pressure over water. When relative humidity is defined in that manner, conditions of saturation (maximum signal) at temperatures below freezing are generally less than 100%RH: TEMPERATURE SATURATION 0 C 100 %RH -10 C 90.7 %RH -20 C 82.3 %RH -30 C 74.6 %RH -40 C 67.8 %RH 3. Temperature Limits The MP601A can operate within -40 C and +60 C. Operating the MP601A outside of the temperature limits may result in inaccurate measurements and can permanently damage the unit. 4. Humidity Limits The MP601A can operate within 0 and 100 %RH. Direct condensation does not damage the sensor. However, the humidity sensor will not provide correct readings as long as condensation is present. 5. Temperature Compensation Practically every make of relative humidity sensor requires a compensation for the effect of temperature on the humidity output signal in order to provide accurate measurements over a wide range of temperature conditions. In the specific case of an instrument using a capacitive sensor, compensation is required because the dielectric characteristics of both the water molecule and the hygroscopic polymer used in the sensor vary with temperature. The MP601A is equipped with an NTC temperature sensor, located next to the humidity sensor, which is used exclusively for the purpose of compensating the humidity sensor. This sensor should not be used for measuring temperature since it would not provide sufficient accuracy. Compensation is automatically done by the electronic circuit of the MP601A, based on the data provided by the NTC sensor. 6. Sensor Protection As a standard, the MP601A is supplied with a D25 wire mesh dust filter. We strongly recommend to always use the filter. The wire mesh filter is suitable for most applications. Coastal and marine applications usually require use of an MF25-MP foam filter.

5 -5- WIRING Because the MP601A can be wired in different manners, it is provided without a cable. The board of the MP601A is equipped with 4 solder pads which are used to attach the power and signal cable. Power Ground Power (+) RH (+) RH (-) Signal Ground Note: Power Ground and Signal Ground are internally separated on the board by two 100 kω resistors in series. A) Shared Signal and Power Ground Wire This configuration economizes one wire and may be used for cable lengths up to 6.5 ft (2 meters). On the board of the MP601A, bridge the power ground and signal ground solder pads. Attach both the cable shield and the ground wire to the Power Ground pad. B) Separate Signal and Power Ground Wires With this configuration, separate wires are used for signal ground and power ground. The 2.5 ma used to power the probe do not flow in the signal ground wire. This permits cable lengths of up to 330 ft (100 meters). Attach both the cable shield and the ground wire to

6 -6- Power Ground pad. The signal ground wire and the power ground wire should be bridged at the opposite end of the cable. Note: Since the probe will have to removed from its location to be calibrated from time to time, we do not recommend using a single long length of cable. Instead of this, attach a short cable to the probe and provide an extension cable with a maximum length of up to 330 feet (100 meters). Humidity (+) Power (+) Humidity Ground (-) Power Ground (-) Shield MP601A Extension Cable Connector C) Adding a Temperature Sensor The sensor bulkhead of the MP601A has two free pins that may be used for adding a temperature sensor. This can be a thermistor, a RTD (2-, 3- or 4-wire connection) or another type of sensor. Attach one or two wires to each pin Customer Supplied Sensor

7 -7- INSTALLATION 1. Probe Location Install the probe so that the local conditions at the sensors are typical of the environment to be measured: Use either a shield or a shelter to protect the probe and sensors from direct exposure to solar radiation and precipitation. Several shields are available from ROTRONIC (see specifications). In an open field, install the probe at least 3.3 feet (one meter) above ground. Increase this distance if the ground surface is concrete of black top (such as above a roof). 2. Grounding Operation of the MP601A does not require that the unit be electrically grounded. However, we strongly recommend grounding the (-) side of the supply voltage to the probe. MAINTENANCE 1) Cleaning or Replacing the Dust Filter: Any filter insert should be cleaned or replaced from time to time, depending on the conditions of measurement. Cleaning should be done without removing the filter from the probe. Gently wipe the filter with a solution of water and mild detergent. If this does not remove most of the stains, the filter should be replaced. To do this, unscrew the filter from the probe. When removing the slotted cap, make sure that the sensors do not get caught. The humidity sensor is sometimes mistaken for a "white paper tag". Do not remove from the probe! Before putting on the slotted cap, check the alignment of the sensors with the probe. The wires that connect the sensors to the probe are very thin and bend easily. If this happens, correct the alignment by holding the sensor very gently with a pair of small flat nosed pliers. Do not puncture the sensor with sharp pliers or tweezers or pull too hard on the sensor. 2) Periodic Calibration Check: Long term stability of the humidity sensor is typically better than 1 %RH per year. For maximum accuracy, calibration of the unit may be verified every 6 to 12 months. Applications where the probe is exposed to significant pollution may require more frequent verifications. The calibration procedure is described in detail in this manual.

8 -8- CALIBRATION BASICS 1. Humidity Calibration When calibrating humidity, temperature stability is the single most important requirement. Do not calibrate unless the probe is at room temperature (20 to 25 C) and this temperature is stable to ±0.25 C or better during the period of time required for each calibration point. Do not calibrate close to an air vent or a heater, in direct exposure to sun rays, etc. If necessary during calibration, place the tip of the probe with the calibration device on it (see below) inside an insulating box filled with sand. a) Calibration Device: The calibration device is a small airtight container that fits on the instrument probe and seals around the humidity sensor. During calibration, a known reference humidity is produced inside the calibration device by means of a humidity standard (usually an aqueous salt solution). The calibration device model EM25 fits the MP601A. To install on the probe, remove the sensor protection (dust filter) and screw in its place the calibration device. Be very careful during this operation since the sensors are not mechanically protected. b) Humidity Standards: RIC humidity standards permit calibration by non-skilled personnel. These standards are available in boxes of 5 glass ampoules of the same value, which can be stored indefinitely. Standards in the range of 5 to 95 %RH are non-saturated aqueous salt solutions that are precisely titrated at our factory for the right concentration. The 0 %RH humidity standard is made of small granules of a highly porous ceramic that have been dried at a high temperature. A Material Safety Data Sheet is available for each standard. Since most standards are a salt solution, parts which have come in contact with the liquid should be cleaned after each use. 2. Temperature Calibration If a temperature sensor was added to the probe, it may be necessary to calibrate temperature from time to time. In order to be able to correctly evaluate the accuracy of the temperature measurements provided by the probe, you should be able to meet the following requirements: Both the probe and a reference thermometer should be ventilated with the same stream of air. Any dust filter used to protect the sensors should be removed from the probe.

9 -9- Air velocity should be within the limits of 200 to 500 feet/minute (1 to 2.5 meters/second). Any comparison between two instruments at velocities under 200 feet/minute may not be valid. Air velocity above 500 feet/minute may damage the unprotected humidity sensor. The temperature of the air stream should be as constant as possible. CALIBRATION PROCEDURE 1. Calibration Potentiometers To access the calibration potentiometers unscrew the cable grip so as to free the cable. Next, remove the 3 screws located near the tip of the probe. Carefully pull back the probe barrel over the cable to gain access to the electronic board. H35 H 80 H min 2. Calibration Procedure Calibration should be done exactly in the sequence indicated in this manual. The first calibration adjustment should be at 35 %RH or at a value close to that. Install the calibration device on the probe so that the receptacle (or solution holder) is below the sensors. Remove the receptacle from the calibration device. Connect a voltmeter to the Signal (+) and Signal Ground (-) wires. Set the H80 potentiometer in mid position. Place one fiber disc (each box of RIC humidity standards includes 5 discs) in the receptacle of the calibration device. The purpose of this disc is to prevent accidental spilling of the solution inside the calibration device or on the humidity sensor. Tap the top of one ampoule of 35 %RH solution so that all liquid drops to the bottom of the ampoule. Snap off top and empty contents on fiber disc. Since the ampoule is

10 -10- made of glass, exercise proper caution (gloves, safety glasses) when snapping off the top. Put the receptacle back on the calibration device and make sure that the solution does not come in contact with the sensor: The solution inside the calibration device should never be on top of the sensors. Allow at least 60 minutes to insure that the calibration device, the solution and the sensor are in a state of equilibrium. This is verified by monitoring the voltmeter. At equilibrium (stable output signal), adjust the reading of the voltmeter with the H35 potentiometer. Remove the receptacle from the calibration device. Throw away the wet disc (non reusable). Thoroughly wash and dry the receptacle with a soft tissue, removing all traces of the humidity standard. Use 80 %RH as the second calibration value as this provides the best overall accuracy over the full range of measurement. Repeat the procedure used for the 35 %RH adjustment with an 80 %RH standard. Allow at least 60 minutes for equilibrium. At equilibrium, adjust the probe output with the H80 potentiometer Remove the receptacle from the calibration device and clean thoroughly. The low humidity calibration is the last step of the calibration sequence. Repeat the procedure used before with either a 10%RH or a 0 %RH standard. Allow at least 90 minutes for equilibrium. At equilibrium, adjust the probe output with the H min potentiometer Carefully remove the calibration device from the probe (pay attention not to catch the unprotected sensors). Put the dust filter back on the probe. Thoroughly clean the receptacle.

11 -11- SPECIFICATIONS Model MP601A Meteorological Humidity Probe Humidity Sensor ROTRONIC HYGROMER C94 Humidity Measuring Range %RH Temperature Operating Limits C Humidity Output Signal (linear) VDC = %RH Output Minimum Load 1000 Ω Accuracy (at C) ± 1 %RH from 0 to 100%RH *) Repeatability ± 0.3 %RH Humidity Sensor Stability better than 1 %RH over a year Response Time (without filter) 10 seconds Calibration Potentiometers 35, 80%RH and RH min. Supply Voltage 4.8 to 30.0 VDC Max. Current Consumption 2.5 ma when powered with 12 VDC or less Sensor Protection Standard: D25 wire mesh filter Optional: MF25-MP foam filter Cable User provided and installed Weight 70g (0.16lb) *) When calibrated against highest quality reference standards. Both factory calibration and field calibration with ROTRONIC standards result in ±1.5%RH accuracy or better. Accessories (order separately) Natural Aspiration Shield Motor Aspirated Shield Calibration Device SMP MAS (12 VDC, 75 ma) EM25 Dimensions in mm / Modifications Reserved

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION... 3 OPERATION... 4 MEASUREMENT... 5 MAINTENANCE... 7 CALIBRATION BASICS... 8 CALIBRATION PROCEDURE... 10 SPECIFICATIONS...

More information

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL -2- CONTENTS DESCRIPTION...3 OPERATION...3 INSTALLATION (Tips for fixed probe installation)...4 MAINTENANCE...6 CALIBRATION...6 SPECIFICATIONS...8 PLEASE,

More information

Model 5190-E Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe Model 5190-E Temperature/Humidity Probe User s Manual Rev. D All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2010, All Weather, Inc. All Rights

More information

Model 5190-F Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

More information

HYGROMER - MP 400 A Meteorology probe

HYGROMER - MP 400 A Meteorology probe HYGROMER - MP 400 A Meteorology probe Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 400A for measuring humidity and temperature, you have purchased a precision measuring

More information

HYGROMER MP 100 A Meteorology probe

HYGROMER MP 100 A Meteorology probe HYGROMER MP 100 A Meteorology probe Bedienungsanleitung Mode d emploi Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 100A for measuring humidity and temperature, you have

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 90.7031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric) Data Sheet 907031 Page 1/7 Hygro/hygrothermal transducers (hygrometric) for measuring relative humidity and temperature for mounting indoors, outdoors, and in air ducts with resistance, current or voltage

More information

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY S E C T I O N 10 C O N T E N T S N A V I G A T I O N Introduction.................... 10.2 Portable Meters................. 10.3 Transmitter..................... 10.9 Probes......................... 10.10

More information

HI COD REACTOR and Test Tube Heater 2008 Series

HI COD REACTOR and Test Tube Heater 2008 Series Instruction Manual HI 839800 COD REACTOR and Test Tube Heater 2008 Series www.hannainst.com This Instrument is in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna product.

More information

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration

More information

SUNSTAR 传感与控制 TEL: FAX: Instructions for Humidity Calibration with Salt Solu

SUNSTAR 传感与控制   TEL: FAX: Instructions for Humidity Calibration with Salt Solu Instructions for Humidity Calibration with Salt Solutions of Series EE16 Transmitters 1. General 1.1. Purpose: These instructions describe the procedure for the humidity calibration of the Series EE16

More information

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications Data Sheet 907020 Page 1/9 Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications For measuring relative humidity and temperature For versatile climatic applications and ventilation

More information

Model OEM-2 INSTRUCTIONS FOR USE

Model OEM-2 INSTRUCTIONS FOR USE ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set

More information

RLD-H10P Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector FANs 125, 121 Product/Technical Bulletin RLD-H10P Issue Date 0396 RLD-H10P Refrigerant Leak Detector The RLD-H10P is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS HP727S Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS 1. General Description 2. Specifications 3. Installation Instructions 4. Electrical Wiring 5. Instrument Wiring

More information

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual Automatic Humidity Controller Model 512 (Revision C) Operating Manual 6/5/03 1 TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 GENERAL DESCRIPTION 3 3 2.1 Humidity Sensor 3 2.2 Control Unit 4 2.3 System Operation

More information

Duct Humidity/Temp Sensor

Duct Humidity/Temp Sensor Duct Humidity/Temp Sensor Model HU-226 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from

More information

Room Humidity/Temp Sensor

Room Humidity/Temp Sensor Room Humidity/Temp Sensor Model HU-225-EU (Not Available in North America) RoHS Ultra fast response cross-linked bulk polymer...capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 05-575 MiniMonitor III Multipurpose X and Gamma Ray Survey Meter Operators Manual February 2005 Manual No. 05-575-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed

More information

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

Humidity Measurement Technology pros & cons. Helping you make a better measurement. Humidity Measurement Technology pros & cons Helping you make a better measurement. Webinar Presenters & Humidity Experts Bruce McDuffee Michael Boetzkes Agenda & Takeaways Agenda Parameter review Mechanical

More information

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications Data sheet 907020 Page 1/7 Hygro and Hygrothermo Transducers (capacitive) for climatic applications To measure relative humidity and temperature For versatile climatic applications and ventilation For

More information

Selecting the right humidity sensor for your application

Selecting the right humidity sensor for your application Selecting the right humidity sensor for your application Humidity is the presence of water in the air. The amount of vapour can affect human comfort as well as many manufacturing processes. Monitoring

More information

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Document No. 155-755 Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air Description Features Application The Q-Series Relative Humidity and

More information

RLD-H10G Refrigerant Leak Detectors

RLD-H10G Refrigerant Leak Detectors FANs 125, 121 Product/Technical Bulletin RLD-H10G Issue Date 0396 RLD-H10G Refrigerant Leak Detectors The RLD-H10G is a professional grade leak detector for use by refrigeration and air conditioning technicians.

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards 3 Operating

More information

SIMRAD GD10PE IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application

More information

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions 1.0 GENERAL INFORMATION Every SRH humidity sensor product is tested and calibrated before

More information

Potential Applications

Potential Applications HIH-4602-L HIH-4602 Series monolithic IC humidity sensor with integral precision RTD in TO-39 Features Linear voltage output vs %RH Laser-trimmed interchangeability Chemically resistant Enhanced accuracy,

More information

SimpleVIS Viscometer Reference Guide P

SimpleVIS Viscometer Reference Guide P SimpleVIS Viscometer Reference Guide P82.0090 Run Status Indicator Lamps Sample/Solvent Port Waste Bottle Dust Cover Temperature Calibration Port Touch Screen Display RS-232 Serial Port Exhaust Muffler

More information

for relative humidity and temperature with calibration certificates

for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 QFA4160 AQF4150 Symaro Room Sensor for relative humidity and temperature with calibration certificates QFA4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for

More information

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..

More information

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6

More information

DAWN Electronics, Inc.

DAWN Electronics, Inc. APPLICATIONS INFORMATION THE ELECTRONICS PROPORTIONALLY CONTROLLED HEATE THEORY OF OPERATION All standard Dawn Proportionally controlled heaters (Fig. 1) are basically the same. They consist of a temperature

More information

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting

More information

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD NH 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard NH 3 Operating and Instruction Manual General description. 4 Installation.. 4

More information

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Operating voltage AC 24 V / DC 13535 V Signal output DC 010 V / 420 ma for relative humidity Signal output DC 010 V / 420 ma

More information

0-10 V Wall & Duct Humidistat Installation Instructions

0-10 V Wall & Duct Humidistat Installation Instructions 0-10 V Wall & Duct Humidistat Installation Instructions This document covers the operation and installation instructions for the following Nortec Digital Humidistats: Part #: Description: 1510142 0-10

More information

GAS MONITOR Model Model

GAS MONITOR Model Model Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00

More information

Digital Heat Block User Manual

Digital Heat Block User Manual Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in

More information

Operator s Manual. Histology Bath

Operator s Manual. Histology Bath Operator s Manual Histology Bath 110-827 05.09.12 Table of Contents Introduction... 2 General Safety Information... 2 Safety Recommendations... 3 Unpacking Your Histology Bath...4 Contents...4 Components

More information

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor INSTRUCTION MANUAL Oil-in-Water Monitor Type OMD-12 DECKMA HAMBURG GmbH Kieler Straße 316, D-22525 Hamburg Tel.: ++49 40 54 88 76-0, Fax: ++49 40 54 88 76-10, email: post@deckma.com IMPORTANT NOTICE Replacement

More information

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy

More information

Victoreen Primalert 35 Area Radiation Monitor

Victoreen Primalert 35 Area Radiation Monitor Victoreen 05-437 Primalert 35 Area Radiation Monitor Operators Manual March 2005 Manual No. 126011 Rev. 3 2003, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks

More information

Outside Air Humidity & Temperature Sensor

Outside Air Humidity & Temperature Sensor Outside Air Humidity & Temperature Sensor RoHS Model HU-227 Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing

More information

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..

More information

A measured step forward

A measured step forward A measured step forward Operations & Maintenance Manual TM JESCO UV 405-412-440-450-480-550-80 2 LCD LCD PLUS Contents 1. Introduction...3 2. General Principles and Safety Instructions...4 3. Instructions

More information

Models TX-KE and TX-KP Toxic Gas Transmitters

Models TX-KE and TX-KP Toxic Gas Transmitters Models TX-KE and TX-KP Toxic Gas Transmitters Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Dr. Lake Zurich, IL. 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com

More information

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature 1 864 1864P01 Symaro Duct sensors for relative humidity and temperature QFM21... Operating voltage AC 24 V / DC 13.5...35 V Signal output DC 0...10 V / 4 20 ma for relative humidity Signal output DC 0...10

More information

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...

More information

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL SSCOR/board SUCTION FOR THE EMS VEHICLE SSCOR, INC. 11064 Randall Street Sun Valley, CA 91352 USA Telephone +1-818-504-4054 800-434-5211 Fax +1-818-504-6032

More information

CMT MANUAL 6. NMC SENSORS

CMT MANUAL 6. NMC SENSORS CMT MANUAL 6. NMC SENSORS TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS... 5 6.1 INTRODUCTION... 6 6.2 TEMPERATURE AND HUMIDITY SENSORS... 7 6.2.1. TEMPERATURE SENSOR... 7

More information

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - wwwmytubcouk - info@mytubcouk 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21 Use Operating voltage

More information

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications: Industrial Chilled Mirror Hygrometer Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System ForceFrost TM function Ice-Test user calibration verification User configurable

More information

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement. Humidity Measurement Technology Pros & Cons Helping you make a better measurement. Webinar Presenters & Humidity Experts Bruce McDuffee Michael Boetzkes Agenda & Takeaways Agenda Parameter review Mechanical

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a

More information

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN: TM... TECHNICAL MANUAL MODEL USN-50 DESCRIPTION Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN: Commercial & Marine Cooking Equipment Gas & Electric Last Updated September

More information

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS

More information

RK CO 2 Transmitter Operator s Manual

RK CO 2 Transmitter Operator s Manual 65-2397RK CO 2 Transmitter Operator s Manual Part Number: 71-0185RK Revision: B Released: 7/18/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

USER S GUIDE Version: FM M AIR CURTAINS

USER S GUIDE Version: FM M AIR CURTAINS USER S GUIDE Version: FM35-201705M AIR CURTAINS Models: FM-3509-L/Y, FM-3510-L/Y, FM-3512-L/Y, FM-3515-L/Y (2 Speeds with Magnetic Switch) Thanks for purchasing this Air Curtain. PLEASE READ AND SAVE THESE

More information

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring Data Sheet 90.7021 Page 1/6 Hygro and hygrothermo transducers (capacitive) for HVAC monitoring for measuring relative humidity and temperature for HVAC applications as indoor, wall and duct versions special

More information

USER MANUAL 04-0_MOD-KH1204US_H9 Objecto.indb _MOD-KH1204US_H9 Objecto.indb /06/29 15:02: /06/29 15:02:46

USER MANUAL 04-0_MOD-KH1204US_H9 Objecto.indb _MOD-KH1204US_H9 Objecto.indb /06/29 15:02: /06/29 15:02:46 USER MANUAL 2 Safety Information Before use, be sure to carefully read all information to ensure that you use this product correctly. Always follow this information when using this unit. WARNING Do not

More information

POWER METER INSTRUCTION MANUAL

POWER METER INSTRUCTION MANUAL POWER METER INSTRUCTION MANUAL FOR KPD-1000 Version 1.0 Please read this instruction manual carefully and thoroughly Before installing or operating your power meter. TABLE OF CONTENTS 1. Introduction Introduction......1

More information

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS Portable Industrial Chilled Mirror Hygrometer Fundamental drift free humidity measurement Integral frost/dew point measuring head Internal sample pump Optimal Response Injection System for fast measurement

More information

Ionizer (Static Remover) STABLO-EX Instruction Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual 321-56879-21E Jan. 2009 For Electronic Balances Ionizer (Static Remover) STABLO-EX Instruction Manual Read the instruction manual thoroughly before you use the product. Retain this instruction manual for

More information

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC. Fig. 2: Blower & Evaporator Unit Specifications 2004 HVAC SYSTEMS Manual HVAC System - Sorento GENERAL SPECIFICATIONS AIR CONDITIONER Fig. 1: Air Conditioner Specifications BLOWER AND EVAPORATOR UNIT HEATER

More information

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Installing the Cisco ONS FAP-4 Fuse Alarm Panel Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document

More information

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) PART 1 - GENERAL A. RELATED DOCUMENTS SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu) Federal, State, and local requirements as applicable. Attached Permit Attached drawings B. SUMMARY 1. Provide

More information

Thermo-hygrometer. Use and maintenance manual Update 3 Apr INSTUM_01378 Pag. 1/8

Thermo-hygrometer. Use and maintenance manual Update 3 Apr INSTUM_01378 Pag. 1/8 Thermo-hygrometer DMA867 and DMA875 Use and maintenance manual Update 3 Apr 2014 INSTUM_01378 Pag. 1/8 Index 1 Description... 3 1.1 Main features... 3 1.2 Models and technical specifications... 3 2 Product

More information

Meteorology 432. Hygrometry Spring 2013

Meteorology 432. Hygrometry Spring 2013 Meteorology 432 Hygrometry Spring 2013 Hygrometry Objective: Determine the amount of water vapor present in the atmosphere. Pure water vapor in equilibrium (saturated conditions) with a plane surface of

More information

BC-HTO RELIABLE SENSING TECHNOLOGY

BC-HTO RELIABLE SENSING TECHNOLOGY BC-HTO DUCT MOUNT INSTALLATION The Series RHP duct mount transmitters are ideal for monitoring humidity and temperature in supply or return air ducts. For quick verification of measurements, an optional

More information

Desiccant / Pump Dehumidification System. Model Operating Manual

Desiccant / Pump Dehumidification System. Model Operating Manual Desiccant / Pump Dehumidification System Model 5471 Operating Manual 6/30/06 www.electrotechsystems.com TABLE OF CONTENTS Model 5471 Desiccant / Pump Dehumidification System PARAGRAPH DESCRIPTION PAGE

More information

CEM 2 Stage Probe. Part # 07202, 07204, 07206, 07208, Self-Regulating Heater Part # (optional) User Manual May, 2008

CEM 2 Stage Probe. Part # 07202, 07204, 07206, 07208, Self-Regulating Heater Part # (optional) User Manual May, 2008 212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 CEM 2 Stage Probe Part # 07202, 07204, 07206, 07208, 07210 Self-Regulating Heater Part # 07275 (optional) User Manual May, 2008 Questions? Contact us

More information

Black Body Calibration Source User Manual

Black Body Calibration Source User Manual Black Body Calibration Source Surface Plate Type with External Controller Model CBB18GC- 2 WD1069 Rev B 10/23/17 Wahl Instruments Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free: 800-421-2853

More information

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10 DESCRIPTION FEATURES PRODUCT DATA Solid and Split Core Vdc Output Current Transmitters. Fast Response Time. Integral

More information

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG FastGene Plate Centrifuge Instruction Manual Catalog No. NG040 www.nippongenetics.eu info@nippongenetics.eu Version 01 20.01.2015 Content -1x Plate Centrifuge -2x Adapter for 96 well plates -1x Power Cord

More information

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................

More information

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature 1 864 1864P01 Symaro Duct Sensors for relative humidity and temperature QFM21... Use Type summary Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity Signal output

More information

JENCO ELECTRONICS, LTD.

JENCO ELECTRONICS, LTD. OPERATION MANUAL THE JENCO MODEL 3677 1/8 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISON INSTRUMENTS GENERAL INTRODUCTION The model 3677 is a precise instrument for the measurement

More information

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet FTK+ Duct sensor for humidity and temperature Datasheet Subject to technical alteration Issue date: 03.04.2018 A002 Application Duct humidity and temperature sensor in new hinged lid enclosure USE for

More information

The GAK-800 Heated Exercise Gas Analyzer Accessory Kit

The GAK-800 Heated Exercise Gas Analyzer Accessory Kit Tech Note The GAK-800 Heated Exercise Gas Analyzer Accessory Kit Overview The GAK-800/801 are heated pneumotach and controller kits for use with iworx kits, like the MC-214, that are capable of measuring

More information

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS

More information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS SEEKIRK, INC. 2420 Scioto Harper Dr. Columbus, OH 43204 Tel: (614) 278-9200 FAX: (614) 278-9257 email: seekirk@seekirk.com

More information

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times USER MANUAL MODELS: COX 115V-N COX 220V-N COX 115V-R COX 220V-R 2364 Leicester Road, P.O. Box 175, Leicester, NY 14481 Phone (585)

More information

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc. MSPA-MP METAPACK SERVICE MANUAL Gecko Electronics Inc. Visual step-by-step guide to easily identify & correct technical problems! Table of Contents Power & Ground Check Tools and Parts 3 Electrical Wiring

More information

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX (219)

More information

Corning LSE 6L Digital Water Bath

Corning LSE 6L Digital Water Bath Corning LSE 6L Digital Water Bath INSTRUCTION MANUAL Models 6783 (120V US) 6784 (230V EU) Table of Contents 1.0 Warning 1 2.0 Safety Information 1 3.0 Package Contents 1 4.0 Unpacking 2 5.0 Installation

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

Revolutionary Science RS-IF-202

Revolutionary Science RS-IF-202 Instruction Manual for the Revolutionary Science RS-IF-202 Incufridge TABLE OF CONTENTS PAGES Recommended Safeguards 2 Introduction 3 Operating Instructions 4 Care and Maintenance 5 Specifications 5 Contact

More information

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13 USER MANUAL 2 Safety Information Before use, be sure to carefully read all information to ensure that you use this product correctly. Always follow this information when using this unit. WARNING Do not

More information

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL THE JENCO MODELS 3672, 3673, 3675 1/4 DIN ph/orp CONTROLLER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS INTENDED USE AND GENERAL INTRODUCTION The models 3672, 3673 and

More information

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series Humidity Sensors Line Guide Performance and reliability. Just because humidity products are typically standardized and platform-based, they can still deliver superior performance right out of the box.

More information

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2.

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2. Figure 1 This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2. Reasons for reissue are provided in Section 9, REVISION

More information

Model gffoz Process Ozone Sensor (In-Line)

Model gffoz Process Ozone Sensor (In-Line) Date ECO# Rev Description Originator 9/15/97 1.0 First Publication DB 10/8/97 2.0 Miscelaneous corrections DB 10/28/97 3.0 Minor changes BM 5/1/98 3.1 Added CE compliance BM TM IN USA, INCORPORATED 87

More information

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual GG-H2S HYDROGEN SULFIDE GAS SENSOR Installation and Operation Manual 2 GG-H2S Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by

More information

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet. StableTemp Low Temperature Incubator Model 146E Catalog Number 39063-00(115VAC) 39063-05(230VAC StableTemp Low Temperature Incubator offers laboratories precise temperature control over the -10 C to 60

More information