OPERATOR S MANUAL. Horizontal Laminar Flow Clean Bench

Size: px
Start display at page:

Download "OPERATOR S MANUAL. Horizontal Laminar Flow Clean Bench"

Transcription

1 OPERATOR S MANUAL Horizontal Laminar Flow Clean Bench MODELS: EG3252/EG4252/EG4320/EG5252/EG6320/EG8252/EG8320

2 P. O. Drawer E / 161 Gatehouse Road / Sanford, Maine / USA / / Fax: / bakerco@bakerco.com / bakerco.com Welcome to Baker Thank you for choosing to join the growing number of people who are achieving excellence in science and clinical care through clean air, containment, and incubation solutions from Baker. As a fixture in laboratories and clinical settings around the world, Baker takes special pride in helping people just like you to create optimal environments for their work, while providing a safe and comfortable user experience. At Baker, nothing is more important to us than the trust you place in our solutions to help you achieve your goals. Whether you are involved with basic scientific research, drug discovery, or patient care, Baker has a proven record of delivering high-performing equipment through an uncompromising commitment to safety, testing, quality, and craftsmanship. Additionally, as a Mainebased family owned business in operation for more than 60 years, you can rest assured that Baker will be there for you throughout the life cycle of your new equipment. Baker is a pioneer in the field of biological safety, and our reputation is built on taking no shortcuts and making no compromises when it comes to user safety. We are the only manufacturer to routinely subject our own equipment to extensive microbiological aerosol testing in the most challenging conditions above and beyond what the average user would ever encounter. However, the adequacy of any equipment for user safety in a specific application should always be evaluated. This risk assessment should be performed by an industrial hygienist, safety officer, or other qualified person representing the purchasing organization. Remember that you, the owner and user, are ultimately responsible and that you use this equipment at your own risk. I recommend that you keep a copy of this manual, along with the factory test report (if applicable), near your new equipment for convenient reference by operators and qualified maintenance personnel. If you have any questions about the use or care of your Baker equipment, please do not hesitate to contact our Technical Service Department for assistance at (800) ( outside the United States) or techsupport@bakerco.com. Thank you for placing your trust in Baker. Sincerely,

3 P. O. Drawer E / 161 Gatehouse Road / Sanford, Maine / USA / / Fax: / bakerco@bakerco.com / bakerco.com David Eagleson President The Baker Company, Inc. Table of Contents Function of the EdgeGARD HF... 1 Clean Bench Design... 2 Regulatory Compliance... 4 Standards... 4 Cautionary Notes... 4 Standard Features... 5 Controls... 5 Filters... 5 Prefilter... 5 High Velocity Return Air Slots... 6 Lighting... 6 Motor Speed Control... 6 Outlets... 6 Pharmacy Configuration... 6 Spill Guard... 6 Optional Features... 7 Alarms... 7 Clean Bench Airflow Alarm... 7 Clean Bench Airflow Monitor D000D.docx i

4 P. O. Drawer E / 161 Gatehouse Road / Sanford, Maine / USA / / Fax: / bakerco@bakerco.com / bakerco.com Anchoring Systems... 7 Anchors... 7 Cable Port... 7 Extra Deep Work Surface... 7 IV Bar... 7 Outlets... 8 Plastic Storage Bins... 8 Pull Bars... 8 Pressure Monitor... 8 Service Connections... 8 Hardware... 8 Quantity and Exiting Direction... 8 Material... 8 Stand (Console)... 9 Base Risers... 9 Casters... 9 Leg Risers... 9 Ultraviolet Light (UV)... 9 Proper Clean Bench Use...10 Controls...11 Operation...12 Receptacle/Outlets...12 Fluorescent Light...12 UV Light (Optional)...12 Blower...13 Alarm Conditions...13 Clean Bench Airflow Alarm...13 Clean Bench Airflow Monitor...13

5 P. O. Drawer E / 161 Gatehouse Road / Sanford, Maine / USA / / Fax: / bakerco@bakerco.com / bakerco.com Start-up Procedure...13 Working in the Clean Bench...14 Using Ancillary Equipment...16 Reacting to Spills...16 Cleaning and Disinfecting Stainless Steel...17 Simple Cleaning...17 Disinfection...17 Cleaning Spills...18

6 Function of the EdgeGARD HF The EdgeGARD HF is a horizontal flow clean bench that provides product protection by delivering HEPA filtered supply air to the work area. The EdgeGARD HF does not provide any personnel or environmental protection. In operation, the EdgeGARD HF delivers HEPA filtered, unidirectional airflow to the work area in a horizontal direction. Initially room air is pulled inward through the lower louvered front panel(s), where it passes through a prefilter which removes large particulate from the air stream. The pre-filtered air is then drawn into a supply fan which forces the air into a plenum directly behind the supply HEPA filter. The pressurized air is forced through the supply HEPA filter and diffuser delivering a relatively uniform airflow at an average velocity of 100 FPM (.51 m/s) to the work area providing a better than ISO Class 5 work area. Concurrently, room air is drawn into the base of the clean bench through sections of high velocity air slots located along the work area sidewalls and leading edge of the work surface. The airflow into the high velocity air slots prevents the intrusion of particles from outside of the clean bench into the workspace maintaining the ISO Class 5 environment. CAUTION Proper equipment for any application should be determined after an assessment of risk by a qualified researcher and an industrial hygienist or bio-safety officer. 1

7 Figure 1. Clean Bench Airflow Clean Bench Design Figure 2 below shows the standard construction and components of the clean bench. 2

8 Pharmacy Diffuser (HEPA Filter Behind Diffuser) Stainless Steel IV Bar (Optional) Pressure Gauge (Optional) High Velocity Return Air Slots Stainless Steel Side Walls Work Surface Spill Guard Behind Diffuser Stainless Steel Work Surface Hinged Cleaning Panel Casters (Optional) Control Panel Figure 2. Clean Bench Features 3

9 Regulatory Compliance Standards This Baker product has been designed, manufactured and tested to comply with the following regulatory standards where applicable. Unless stated otherwise, the most recent edition of these standards has been applied. Electrical, Mechanical, Fire and Personal Safety: Electrical Equipment For Measurement, Control and Laboratory Use, General Requirements US: UL CANADA: CAN/CSA C22.2 No INTERNATIONAL: Low Voltage Directive 2006/95/EC; EN Electromagnetic Compatibility: Electrical Equipment For Measurement, Control and Laboratory Use, EMC Requirements INTERNATIONAL: Electro Magnetic Compatibility Directive 2004/108/EC; EN Hazardous Waste Abatement: Restriction of Hazardous Substances Directive, RoHS, 2011/65/EU; EN50581 Biological Safety: US: Biosafety Cabinetry Certification; NSF/ANSI 49 INTERNATIONAL: Biotechnology Performance criteria for microbiological safety cabinets; EN Industry Guideline References: IEST-RP-CC002.3: Unidirectional Flow Clean-Air Devices, Institute of Environmental Sciences and Technology, 2340 S. Arlington Heights Road, Suite 100, Arlington Heights, IL , USA, Cautionary Notes Hazards may still exist, especially if the clean bench is not installed, operated and maintained according to the instructions in this manual and the service manual. 4

10 This clean bench may be affected by high levels of electromagnetic radiation from other electronic devices that are being used in close proximity or connected to the same facility power system. This clean bench may cause radio interference or affect the operation of other equipment in close proximity. Mitigation measures such as relocation, re-orientation, or shielding may be required. Standard Features Controls There are rocker style switches to control power to the electrical outlets, fluorescent lights and the motor/blower on the clean bench. When the UV light option is installed, the light switch is dual purpose controlling both the fluorescent light and UV light. Filters CAUTION Filter media is very delicate and should never be touched. Only qualified technicians should replace HEPA filters. The High Efficiency Particulate Air (HEPA) filter is a disposable, dry type filter made of a continuous sheet of glass fibers which are pleated and sealed in a rigid metal frame. Baker clean benches are designed using HEPA filters with a minimum of 99.99% efficient on 0.3 micron size particle size (IEST- RP-CC001 Type C), or a minimum of 99.99% efficient at 0.1 to 0.2 or 0.2 to 0.3 micron particle size (IEST-RP-CC007 Type J). Each filter is leak checked after installation to ensure the integrity of the media and gasket seal perimeter. Prefilter Prefilters are made of a course material placed upstream or before the work area HEPA filter used to capture large particles. The prefilters can be cleaned using a HEPA vacuum and mild detergent and reused. 5

11 High Velocity Return Air Slots High velocity return air slots are located at the front access opening on both sidewalls and horizontally along the work surface. The purpose of the slots is to improve the clean bench integrity by capturing any particulates at these critical transitions. Lighting The work area is illuminated to provide a minimum average light intensity of 100 foot-candles (1076 lux) at the work surface. This clean bench features solid-state electronic ballasts for the visible and optional UV lighting. These ballasts increase reliability, efficiency and service life with lower heat output. Motor Speed Control The StediVOLT TM speed controller compensates for normal fluctuations in line voltage and is designed to maintain relatively consistent air flow when the clean bench filter(s) load. This helps to maintain airflow in the clean bench. Outlets The clean bench has one outlet below the work surface for powering instruments inside the work area. The outlet is protected by a self-resetting circuit breaker rated at 5 Amps. On 115V clean benches these outlets are protected by a Ground Fault Circuit Interrupter (GFCI). Pharmacy Configuration The pharmacy kit delivers first air (unidirectional HEPA filtered air) to the critical site of the workspace. The configuration includes a hinged diffuser, hardware and support clips used to position the diffuser for easy work surface cleaning. Spill Guard The work surface has a raised lip at the rear to prevent accidental spills from entering the HEPA Filter area. 6

12 Optional Features Alarms Clean Bench Airflow Alarm This option includes a switch to monitor the air pressure in the supply plenum and an audible alarm to alert the operator when an unsafe air pressure condition exists. Clean Bench Airflow Monitor This option provides a digital pressure gauge to monitor and display the air pressure in the supply plenum. Visual and audible alarms alert the operator when an unsafe air pressure condition exists. The audible alarm can be muted for five minute intervals. Anchoring Systems Anchors Floor and wall restraints are available without California OSHPD pre-approval. Cable Port Cable ports can be located in the left or right sidewall. Cable ports provide a safe means of introducing power and/or data cables, siphoning tubes, etc., into the work area of the clean bench without having to use the front opening. Extra Deep Work Surface The extra deep work surface provides additional work surface toward the back of the clean bench. IV Bar The clean bench can be equipped with an intravenous (IV) bar to facilitate the hanging of required materials. 7

13 Outlets Additional outlets can be mounted in the side wall(s) of the clean bench. A total of four outlets are allowed. The outlet circuit is protected by a self-resetting circuit breaker allowing 5A total for all outlets. On 115V units the outlets are protected by a Ground Fault Circuit Interrupter (GFCI). Plastic Storage Bins Plastic bins for storage can be purchased and are installed below the base of the clean bench. Pull Bars The clean bench can be equipped with pull bars to facilitate ease of movement within the laboratory when casters are installed. Pressure Monitor An optional analog pressure gauge displays the air pressure in the supply plenum. Service Connections Hardware Stainless steel petcocks, needle valves, and stainless steel needle valves are all available as alternative plumbing hardware. Quantity and Exiting Direction Factory installed services are available on either sidewall. Material Optional plumbing is available in black iron piping, copper or stainless steel. 8

14 Stand (Console) Base Risers The 10 (254 mm) base risers provide work surface heights of 40 3 /8 to 42 3 /8 (1025 mm to 1076 mm). The 12 (305 mm) base risers provide work surface heights of 42 3 /8 to 44 3 /8 (1076 mm to 1127 mm). Casters The 5 (127 mm) caster option provides a 36 (914 mm) work surface height. There are two 6 (152 mm) caster configurations, the first provides a 39 (991 mm) work surface height, the second provides a 42 (1067 mm) work surface height. Leg Risers The 6 (152 mm) adjustable leg risers provide work surface heights of 35 3 /4 to 37 1 /2 (908 mm to 953 mm). Ultraviolet Light (UV) WARNING UV light is hazardous, DO NOT use without UV shade down! Eyes and skin should not be exposed to direct UV light. The clean bench may be equipped with a UV light that provides an initial minimum intensity of 40 microwatts per cm 2 at the work surface. When the UV light is on the UV shade must be fully closed to protect the operator. 9

15 Proper Clean Bench Use CAUTIONS A clean bench provides product protection only. Hazardous materials should never be used with this clean bench. Explosive or flammable substances should never be used in this clean bench. Biological, chemical, radiological, or other hazardous substances should never be used in this clean bench. A clean bench is a valuable supplement to, but not a replacement for, good laboratory technique and safe practice. If the operator does not operate the clean bench correctly, it may not provide adequate protection. To ensure product protection the workstation must be operated per the manufacturer s instructions. Baker clean benches are designed for continuous operation. It is recommended that the blower be left on at all times to provide isolation and keep the interior work area clean and free of particulates. Reference sources are National Sanitation Foundation Standard 49 Annex E, and The Biosafety in Microbiological and Biomedical Laboratories (BMBL) 5 th edition published by the U.S. Department of Health & Human Services as HHS Publication No. (CDC) The facility industrial hygienist, pharmacist or biosafety officer shall ensure that: The clean bench is appropriate for all operations and procedures to be performed. All operators are thoroughly trained and competent regarding clean bench operation and all procedures they are required to perform. That the clean bench operation, procedures, and operators are monitored at regular intervals to ensure that safety is maintained. 10

16 Controls The standard operator controls and indicators are arranged below the work surface on the front of the clean bench. There are rocker switches for the receptacle, fluorescent light and blower [Reference Figure 3] Figure 3. Operator Controls Receptacle/Outlet Power On/Off This rocker switch controls the power to the outlet(s). The switch is illuminated when power is supplied to the outlets. Fluorescent Light On/Off This rocker switch controls the fluorescent light. The switch is illuminated when the fluorescent light is on. UV Light On/Off -- When the UV light option is installed, the fluorescent light switch changes from an On/Off rocker switch to an On/Off/On rocker switch. In the upper on position the fluorescent light is on and the upper part of the switch is illuminated. In the lower on position the UV light is on and the lower part of the switch is illuminated. The protective shade should always be fully closed when the UV light is on. 11

17 Blower On/Off This rocker switch controls the operation of the clean bench blower. The switch is illuminated when the blower is on. Operation Receptacle/Outlets The circuit powering the outlets is protected by a self-resetting circuit breaker which allows a total of 5 Amps on all outlets. This helps protect the primary clean bench controls from inadvertent overloads of the clean bench outlets. The clean bench is typically equipped with one outlet below the work surface. For 115V AC/60Hz clean benches, the outlets are also protected by a Ground Fault Circuit Interrupter (GFCI). The GFCI outlet is typically installed below the work surface. Additional optional receptacles are wired such that they are also protected by the GFCI. If the GFCI is tripped by the presence of an unsafe condition a red indicator on the GFCI will be on and the reset button on the front of the GFCI will be extended. Once the fault condition is corrected press the [RESET] button to reconnect power to the outlets. There is also a [TEST] button on the front of the device. The manufacturer recommends that the GFCI device be tested monthly to assure safe operation. Fluorescent Light The fluorescent lighting is designed to provide an average intensity of greater than 100 foot-candles (1076 lux) at the clean bench work surface. UV Light (Optional) WARNING UV light is hazardous, DO NOT use if UV shade is not fully closed. Eyes and skin should not be exposed to direct UV light. UV light should not be relied upon as the sole decontaminating agent and its effectiveness should be evaluated for the intended application. NSF/ANSI 49 does not recommend the use of UV lighting for decontamination purposes. Additional surface disinfection should be performed both before and after every clean bench use. 12

18 The UV light is designed to provide a minimum average intensity of 40 microwatts per cm 2 at the clean bench work surface. The intensity of the UV light will degrade over time so should be tested periodically to assure that its performance is adequate for the application. Blower The motor control/motor/blower system is designed to deliver relatively uniform, horizontal flow of HEPA filtered air to the work area at an average velocity of 100 FPM (.51 m/s) providing a better than ISO Class 5 work environment. Alarm Conditions There are no alarms on standard clean bench configurations. Clean Bench Airflow Alarm The optional airflow alarm uses a pressure switch to monitor the supply plenum pressure. A continuous audible alarm alerts the operator to an unsafe airflow condition. This alarm cannot be muted. Clean Bench Airflow Monitor The optional air flow monitor provides a digital display of the supply plenum pressure and is programmed to alert the operator with a visual and audible alarm when an unsafe condition occurs. The mute pushbutton indicator is the visual alarm and is on continuously when an alarm condition exists. The audible alarm is an intermittent tone and can be muted for 5-minute intervals. Start-up Procedure The operator should read and understand the controls and operation section of this manual prior to performing this procedure. 1. If the unit has not been left running continuously, turn on the blower. An indicator light located on the switch will illuminate when the switch is on and the running blower will make an audible sound. 2. With optional analog pressure gauge: check the reading on the analog pressure gauge; the displayed value should remain consistent with the recorded value in the most recent 13

19 certification report. A significant change in pressure should be cause for investigation. This device is not intended to be used for air flow set-point verification. 3. Turn on the fluorescent light. The indicator light on the switch will illuminate along with the interior work area. 4. If the clean bench has the optional UV light installed, lower UV shade and turn UV light on to make sure it is operational. CAUTION Do not operate UV light if UV shade is not fully closed. Turn off the UV light and raise the UV shade. 5. Wipe down all interior surfaces of the clean bench work area with an appropriate surface disinfectant. IMPORTANT Some disinfectants, such as bleach or iodine, may corrode or stain the steel surfaces. Good practice is to thoroughly clean the surface afterward with a detergent, rinse with sterile water and wipe completely dry to prevent corrosion. 6. Place all materials to be used for the next procedure inside the clean bench on the solid work surface. Disinfect the exterior of these materials prior to placing them on the work surface. Implements should be arranged in the clean bench s work area in logical order so that clean and dirty materials are segregated, preferably on opposite sides of the work area. 7. Begin working in the clean bench after it has run for at least 3 minutes. Working in the Clean Bench WARNING Never work inside the clean bench when an alarm condition exists. 14

20 This section contains some suggested basic work practices that should be observed when using a clean bench. It is not intended to be a comprehensive list for all applications. A good reference source is The Biosafety in Microbiological and Biomedical Laboratories (BMBL) 5 th edition published by the U.S. Department of Health & Human Services as HHS Publication No. (CDC) advisory document for safe work practices. The operator s hands and arms should be washed thoroughly with germicidal soap both before and after working in the clean bench. It is recommended that long-sleeved gowns or lab coats with tightfitting cuffs and sterile gloves are worn, to minimize the shedding of skin, or related contaminants, into the work area and to protect hands, arms and clothing from contamination. Avoid using floor-type pipette discard canisters. It is important that used pipettes be discarded into a tray or other suitable container inside the clean bench. This reduces unnecessary movement in and out of the work area. Because of the restricted access, pipetting within the clean bench will require the use of pipetting aids. Work should be performed using slow movements, and the number of movements should be limited as much as possible. All materials required should be placed in the clean bench prior to starting a procedure, and removed at the end of the procedure. Room airflow can significantly affect clean bench operation. Opening and closing doors in the laboratory can cause air disturbances which might interfere with clean bench airflow. This kind of activity should be kept to a minimum while the clean bench is in use. Personnel should avoid walking by the front of the clean bench while it is in use. The location of facility air diffusers and personal fans can have an adverse effect on clean bench safety. Use good aseptic techniques. When a procedure has been completed, all equipment that has been in contact with the research agent should be enclosed and the entire work surface decontaminated. Trays of discarded pipettes, glassware, etc., should be covered. Once this has been done, remove all equipment from the clean bench. WARNING Never use the clean bench to store supplies or laboratory equipment. 15

21 After removing all materials, culture apparatus, etc. from the clean bench, decontamination of all the interior surfaces should be repeated. Check the work area carefully for spilled or splashed solutions that might support bacterial growth or promote contamination. It is recommended that the clean bench be left running continuously to ensure cleanliness. Using Ancillary Equipment The more equipment and material that is placed in the clean bench, the greater the possibility of disrupted airflow. The resulting turbulence can alter the designed airflow and reduce the effectiveness of the clean bench. Reacting to Spills Even when good work practices are used, occasional spills may occur. All spills should be dealt with immediately to prevent contamination and to avoid any damage to the stainless steel surfaces. It is recommended that the operator, in coordination with the facility safety professional, have a written plan available in case of an accidental exposure or spill. The safety plan should include all of the emergency procedures to be followed in the event of an accident. All employees who use the clean bench should be familiar with the safety plan. 16

22 Cleaning and Disinfecting Stainless Steel IMPORTANT After cleaning and disinfection, all surfaces should be rinsed with sterile water and wiped completely dry. Simple Cleaning IMPORTANT Do not use steel wool or steel pads when cleaning stainless steel. Dirt deposits on stainless steel (dust, dirt and finger marks) can usually be removed using warm water, with or without detergent. If this does not remove the deposits, a mild, non-abrasive household cleaner can be used with warm water and bristle brushes, sponges or clean cloths. Iron rust discoloration can be treated by rubbing the surface with a solution of 15% to 20% by volume of nitric acid and water and letting it stand for one to two minutes to loosen the rust. The proper safety equipment should always be used when handling acids. Disinfection The purpose of disinfection is to destroy any organisms that could pose a potential hazard to humans or compromise the integrity of the experiment. To ensure an organism is killed it is important to use a disinfectant in the proper concentration that is known to be effective for the specific organism. See Appendix B of the BMBL 5 th edition for recommendations. Standard disinfectants include: Iodophordetergent, ethanol, phenol and alcohol. Hypochlorite (chlorine bleach) may also be used in dilute concentrations. Caution should be used, as hypochlorite can cause pitting and/or cracking of stainless steel if it is either too concentrated or not completely removed from the surface in a timely manner. Allow an appropriate time to lapse to allow the disinfectant to deactivate the organism, which depends on the specific agent used (ref. BMBL 5 th edition). Follow up with a sterile water rinse and wipe completely dry to protect the stainless steel surface. Disinfect the work area and work surface before and after each procedure. 17

23 Disinfect surfaces of all equipment used. Remove all items from the inside of the clean bench. Place all items that may have come in contact with the agent(s), such as used pipettes, in a plastic bag or other suitable container. Disinfect the entire inside surface of the clean bench. For additional information on cleaning and disinfecting stainless steel, please refer to: Decontamination, Sterilization, Disinfection, and Antisepsis, Vesley, Donald and Lauer, James L., Laboratory Safety Principles and Practices, 2 nd edition, 1995, Fleming, D.O., Richardson, J.H., Tulis, J.J. and Vesley, D., editors, ASM Press, Washington, D.C., pp ; and Biosafety Reference Manual, 2 nd edition, 1995, Heinsohn, P.A., Jacobs, R.R. and Concoby, B.A., editors, AIHA Publications, pp Cable Port Usage CAUTION! Conduct a risk assessment prior to removing or introducing cables or tubing through the cable port passageway. Cabinet decontamination may be required. The cable port provides a safe means of introducing power, cables, vacuum aspiration tubing, etc. into the cabinet work area. These items should be installed prior to initial cabinet use. Removing or introducing items through the cable port after cabinet use shall require a risk assessment as the cable port passageway may be contaminated. Caution labels are provided on the interior and exterior of the cabinet to remind the operator of potential hazards. Cleaning Spills Spills in the work area should be first cleaned and disinfected. Completely decontaminate the work surface. The work surface spill guard will protect the HEPA filter from damage. If a pharmacy diffuser is installed, lift the diffuser and surface decontaminate the work surface, as well as diffuser if necessary. 18

24 The Baker Company, Inc. P.O. Drawer E Sanford, Maine Tel: (207) / (800) Fax: (207) bakerco@bakerco.com Patent pending Air Bypass Armrest, Cable Port This manual includes information for proper biosafety clean bench operation. We recommend that the manual be kept near the clean bench for ready reference. 19

Class II Biosafety Cabinets

Class II Biosafety Cabinets Class II Biosafety Cabinets Proper Use of Biosafety Cabinet A biosafety cabinet (BSC) is a valuable supplement to good sterile technique and a containment device when working with biohazardous agents/materials.

More information

Safe Operating Procedure (Revised 2/10)

Safe Operating Procedure (Revised 2/10) Safe Operating Procedure (Revised 2/10) BIOSAFETY CABINETS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Biosafety Cabinet Classification Biological

More information

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station AES Environmental Operation and maintenance manual VWS Series Laminar Vertical Flow clean work station Contents 1. INTRODUCTION... 3 2. APPLICATIONS AND LIMITATIONS... 4 2.1 Applications:... 4 2.2 Limitations:...

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL HWS & VWS SERIES LAMINAR FLOW CLEAN WORK STATION OPERATION AND MAINTENANCE MANUAL CONTENTS 1. INTRODUCTION 3 2. APPLICATIONS AND LIMITATIONS 4 2.1 Applications 4 2.2 Limitations 4 3. HWS CABINET DESCRIPTION

More information

Biological Safety Cabinets or Fume Hoods Which one to use?

Biological Safety Cabinets or Fume Hoods Which one to use? Biological Safety Cabinets or Fume Hoods Which one to use? Betty Kupskay, MSc, RBP Biosafety Officer Department of Environmental Health and Safety University of Minnesota Minneapolis, MN kupsk001@umn.edu

More information

Appendix C IBC Safe Use of Biosafety Cabinets SOP

Appendix C IBC Safe Use of Biosafety Cabinets SOP Purpose To provide details for the safe operation of biological safety cabinets (BSCs) and ensure adequate containment of biohazards. Biological safety cabinets shall be used: a. For handling biohazardous

More information

Clean Bench Animal Transfer Stations

Clean Bench Animal Transfer Stations Animal Research Products Clean Bench Animal Transfer Stations Welcome to a comfortable clean bench. Underwriter Laboratories Listed Animal Research Clean Benches Comfortable, easily accessible designs

More information

VP, Facilities and Construction Management

VP, Facilities and Construction Management Title: Biological Safety Cabinets Procedure Effective Date: November 2005 Revision Date: February 24, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS SECTION 11 53 53 BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section

More information

OPERATOR S MANUAL. SterilSHIELD Product Protection Only Isolator MODEL SS500

OPERATOR S MANUAL. SterilSHIELD Product Protection Only Isolator MODEL SS500 THE BAKER COMPANY OPERATOR S MANUAL SterilSHIELD Product Protection Only Isolator MODEL SS500 This manual includes information for installation, operation, maintenance and spare parts. We recommend that

More information

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Main Features Greater protection against contamination

More information

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes Page 1 of 5 Title: Biological Safety Cabinet Guidelines Program or Department: Research Document Type: PROCEDURE Effective Date: January 01,2015 Author Steven Hayes Next Review Date: January 01,2016 Reviewing

More information

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class CLASS II, TYPE A BIOLOGICAL SAFETY CABINET SERIES BSC Models: MHE-N300A-PE + PP MHE-N400A-PE + PP MHE-N500A-PE + PP MHE-N600A-PE + PP Optimum protection of personnel, product and environment. BSC Class

More information

5.0 Installation Instructions

5.0 Installation Instructions 5.0 Installation Instructions 5.1 Location Within the laboratory, pharmacy, etc., the ideal location of the biological safety cabinet is away from personnel traffic lanes, air vents (in or out), doors

More information

Clean Air Device. Yale University. Office of Environmental Health & Safety. Primary Containment Device

Clean Air Device. Yale University. Office of Environmental Health & Safety. Primary Containment Device Yale University Office of Environmental Health & Safety Clean Air Device Primary Containment Device Yale University Table of Contents Section 1.0Introduction... 1 Section 2.0Clean Air Devices... 1 2.1

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow General Purpose Laminar Flow Cabinets, Horizontal and Vertical Horizontal Flow 36 48 72 96 Vertical Flow 36 48 72 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets Provides reliable

More information

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC) LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC) Policy: Maintenance of Laboratory Equipment Adopted April 26, 2012 Properly functioning laboratory equipment is a critical

More information

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Adv. 8.4 Guidelines for Biosafety Cabinets Rev UNIVERSITY OF CINCINNATI Environmental University Health Services 556-4968 Health and Safety ADVISORY NO. 8.4: GUIDELINES FOR THE SELECTION, INSTALLATION AND USE OF BIOSAFETY CABINETS (INCLUDING ISSUES

More information

Environmental Health and Safety Biological Safety Program Guidance Document

Environmental Health and Safety Biological Safety Program Guidance Document Environmental Health and Safety Biological Safety Program Guidance Document Title: Guidelines for Biological Safety Cabinets Original Date: January 2005 Revised Date: General: This document defines guidelines

More information

Safe Use of a Class II Biological Safety Cabinet

Safe Use of a Class II Biological Safety Cabinet UBC Biosafety Committee 102-6190 Agronomy Rd. Vancouver BC, V6T 1Z3 Standard Operating Procedure General Use IBC-SOP-002 Effective date: November 20, 2013. Review date: April 30, 2014. Supersedes: N/A.

More information

Florida International University. Biosafety Cabinet Program

Florida International University. Biosafety Cabinet Program Florida International University Biosafety Cabinet Program DEPARTMENT OF RISK MANAGEMENT & ENVIRONMENTAL HEALTH & SAFETY CSC 162 (305) 348-2621 ehs@fiu.edu www.fiu.edu/~ehs An ounce of prevention is worth

More information

PART III. Laboratory equipment

PART III. Laboratory equipment PART III Laboratory equipment 10. Biological safety cabinets Biological safety cabinets (BSCs) are designed to protect the operator, the laboratory environment and work materials from exposure to infectious

More information

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Biological Safety Cabinets. Presented by Mr. Rene Soetens President Biological Safety Cabinets Presented by Mr. Rene Soetens President Biological Safety Cabinets are referred to by several different names, some of the more common are: BSC, Biosafety Cabinet, Bio-Hood and

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations ANIMAL RESEARCH PRODUCTS Biological Safety Cabinets Animal Transfer Stations Energy efficient biological safety cabinets engineered for animal research offer high performance and superior safety. Meets

More information

Biological Safety Cabinets. Biological Safety Cabinets

Biological Safety Cabinets. Biological Safety Cabinets Biological Safety Cabinets Biological Safety Cabinets(BSCs) are among the most effective, as well as the most commonly used primary containment devices in laboratories working with infectious agents. Properly

More information

B. Design meeting requirements of the particular class and type of cabinet as follows:

B. Design meeting requirements of the particular class and type of cabinet as follows: SECTION 11535 BIOLOGICAL SAFETY CABINETS PART 1 - GENERAL 1.1 RELATED SECTIONS A. Section 15212 (22 60 13) Laboratory Gas Connections B. Section 15810 (23 33 00) Ductwork Connections C. Section 16150 (26

More information

IBC Position on Bunsen Burner Use in Biosafety Cabinets

IBC Position on Bunsen Burner Use in Biosafety Cabinets Background: IBC Position on Bunsen Burner Use in Biosafety Cabinets The Bunsen burner was once a part of every microbiology laboratory and is still widely used today. In the past, microbiologists had to

More information

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet Simplifying Your Safety Decisions Now it s easy to select the best biological safety cabinet for your work with gases and

More information

Thermo Scientific 1300 Series A2

Thermo Scientific 1300 Series A2 Thermo Scientific 1300 Series A2 Class II, Type A2 Biological Safety Cabinets Good for you, good for the environment Thermo Scientific 1300 Series A2 Enjoy best-in-class performance and value g Superior

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

General Purpose Laminar Flow Cabinets, Horizontal and Vertical General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a

More information

FagronLab NP-1 UV. Negative pressure workbench. User Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual Negative pressure workbench User Manual Table of contents 1. Introduction... 3 2. Service... 3 3. Warranty... 3 4. Application range... 4 5. Main technical parameters... 4 6. Performance index... 5 Vibration

More information

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories Airstream Class II Type B2 (Total Exhaust) Biological Safety Cabinet, Model AB2-4S_. Shown with optional support stand. Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution

More information

Innovation in air purification unmatched air quality

Innovation in air purification unmatched air quality Thermo Scientific Ductless Fume Hoods Innovation in air purification unmatched air quality Protects the operator from fume and particle hazards Easy to change filters Improved filter clamping eliminates

More information

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B. Air Showers The Safety Solution for Animal Research Laboratories Viva Air Shower, Model - EAS-1B. Main Features 2 High velocity shower jets in excess of 20 m/s ensure efficient scrubbing action to remove

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

General Purpose Laminar Flow Cabinets, Horizontal and Vertical 24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a multitude of applications. p:2 Product

More information

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories Esco Airstream Laminar Flow Clean Bench Model AHC-4D_ Esco Experience Esco is the world leader in premium

More information

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com LabGard NU-602 Biological Safety Cabinet

More information

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741

More information

Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets

Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets Appendix A Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets SECTION I INTRODUCTION This document presents information on the design, selection, function

More information

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI Animal Tissue Culture SQG 3242 Equipment and Lab design Dr. SITI PAULIENA MOHD BOHARI Sign Symbol? Biohazard sign Means? Hazardous For labeling the biological materials that carry a significant health

More information

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for safety equipment used in or in support of

More information

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety Forma 1400 Series Class II, Type A2 Biological Safety Cabinet Superior Ergonomics, Uncompromising Safety Analyze Detect Measure Control TM ELECTRON CORPORATION Redefining the Standard in Ergonomics and

More information

Fume Hood Safety TYPES OF FUME HOODS

Fume Hood Safety TYPES OF FUME HOODS Fume Hood Safety Fume hoods exhaust toxic, flammable, noxious, or hazardous fumes and vapors by capturing, diluting, and removing these materials. Fume hoods also provide physical protection against fire,

More information

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPSCLCMCQRL Merchandising Hot Cabinets Rev. (/) Page of 0 OPERATING and MAINTENANCE INSTRUCTIONS Models: H8NPSCLCMCQRL Merchandising Hot Cabinets Cabinet model number: Cabinet serial number: Authorized Service Agency: Ph: Fax: Keep this manual

More information

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection ESCO Airstream Class II Biohazard Safety Cabinets European Standard EN12469:2000 Tested Class II Design: Personnel, Product / Sample, Environment Protection Safe: Mini-pleated ULPA Filtration for 99.9998%

More information

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories UL 61010 Viva Dual Access Animal Containment Workstation, Model VDA-4A_ Viva Universal Animal Containment Workstation, Model VA2-4A_E Viva Animal Bedding Disposal Workstation Model VBD-4A_ Animal Containment

More information

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets Good for you, good for the environment Thermo Scientific MSC-Advantage Enjoy best-in-class performance and value Superior Containment

More information

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet Rev. 0 (/) Page of 9 OPERATING and MAINTENANCE INSTRUCTIONS Models: HNPS6CLCMQRL i7 Hot Cabinet Cabinet model number: Cabinet serial number: Authorized Service Agency: Ph: Fax: Keep this manual for future

More information

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

A. General Safety LAB/ROOM: INSPECTED BY: DATE: A. General Safety Item Subject Yes, No, A1 Exits are not obstructed, fastened or locked with keys A2 EXIT signs, if installed are clear and illuminated A3 A4 A5 A6 Fire extinguishers and fire blankets

More information

Insta-Therm Series Service, Installation and Operation Manual

Insta-Therm Series Service, Installation and Operation Manual Insta-Therm 16000 Series Service, Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components

More information

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems A Safe, Stable Environment for Culturing Cells Ultra-reliable Queue water-jacketed CO 2 incubators are carefully engineered to provide an optimal, stable growing environment for cultures. Easy Set-Up Control

More information

AIR PURIFIER WITH GERMICIDAL UV LIGHT

AIR PURIFIER WITH GERMICIDAL UV LIGHT Adorable Air Purifiers AIR PURIFIER WITH GERMICIDAL UV LIGHT FOR THE FOLLOWING MODELS : EE-5064 EE-5065 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS AIR PURIFIER.

More information

Model K205 M Plus Part No

Model K205 M Plus Part No Model K205 M Plus Part No. 1.223-820.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-3 Assembly Instructions.........................3

More information

LABORATORY CABINETS 103

LABORATORY CABINETS 103 LABORATORY CABINETS 103 MINIFLO DUE - TYPE 60 COMPACT VERTICAL LAMINAR FLOW CABINET DESIGNED FOR MICROBIOLOGICAL AND PCR PROCEDURES A very compact size (footprint 73x61 cm), for small laboratory or dedicated

More information

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Esco PCR Cabinet, Model PCR-4A_. Thermal cycler shown in picture not included. EN, JACA, AS2252.2, SFDA, SANS 12469 Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Main

More information

IVF/ART Series Laminar Flow Cabinets

IVF/ART Series Laminar Flow Cabinets IVF/ART Series Laminar Flow Cabinets Applications IVF/ART procedures for human and animal reproduction require a controlled work environment. Ultra-clean conditions are required to minimise microbial contamination

More information

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet Airstream Class II, Biological Safety Cabinet (E-series), Model AC2-4E_. Main Features Esco Sentinel Gold microprocessor

More information

BIOLOGICAL SAFETY CABINET

BIOLOGICAL SAFETY CABINET BIOLOGICAL SAFETY CABINET MIT-EHS Biosafety Program - 2014 Learning objectives Learn about different types of laboratory ventilation equipment and their uses in biological research Learn about best practices

More information

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106

MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES. SUBJECT: Infection Control POLICY NO: 106 MARSHALLTOWN MEDICAL AND SURGICAL CENTER LAUNDRY/LINEN SERVICES SUBJECT: Infection Control POLICY NO: 106 PURPOSE: The activities of collecting, processing and delivering an adequate supply of clean linens

More information

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this WL250 Water Treatment System,

More information

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL S-SCORT II Model 15006 SSCOR, INC. 11064 Randall Street Sun Valley, CA 91352 USA Telephone +1-818-504-4054 800-434-5211 Fax +1-818-504-6032 www.sscor.com Email:

More information

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets SECTION 15852 SPECIAL EXHAUST SYSTEMS PART 1 GENERAL 1.01 SUMMARY A. Laboratory Ventilation and Hazardous Exhaust Systems 1. Pre-Design Considerations 2. General Design Criteria 3. Chemical Fume Hoods

More information

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482

More information

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet Airstream Class II, Biological Safety Cabinet (E-series), Model AC2-4E_. Main Features dual exhaust filtered models

More information

E-Chef Hot Food Table Installation and Operation Manual

E-Chef Hot Food Table Installation and Operation Manual E-Chef Hot Food Table Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.

More information

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT University Policy requires that: GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT Equipment and facilities are maintained and tested, where appropriate, to ensure efficient and safe operation; All equipment used

More information

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES PRE INSTALLATION PROCEDURES DANGER! ELECTRICAL SHOCK HAZARD. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could

More information

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories Airstream Class lll, Biological Safety Cabinet, Model AC3-4B_. Main Features Exhaust air is double-filtered

More information

E-Chef Hot Food Table

E-Chef Hot Food Table E-Chef Hot Food Table Original Instructions Installation, Operation and Maintenance Manual This manual is updated as new information and models are released. Visit our website for the latest manual. Part

More information

Model K 280 M Part No

Model K 280 M Part No Model K 280 M Part No. 1.189-205.0 High Pressure Washer Operator Manual Overview...................................1 Precautions................................1-3 Assembly Instructions.........................3

More information

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES FIRE RADIATION SPILL PERSONAL INJURY CHEMICAL SPILL BIOLOGICAL SPILL Exterior Laboratory Hallway Sign EMERGENCY RESPONSE GUIDE Research and Graduate Studies Manager Laboratory Safety 330-672-4996 tom@rags.kent.edu

More information

XPert Balance and Bulk Powder Enclosures

XPert Balance and Bulk Powder Enclosures XPert Balance and Bulk Powder Enclosures Labconco Product Diversity Glove Boxes Fume Hoods Biological Safety Cabinets Freeze Dryers Glassware Washers Filtered Enclosures Carts & Mobile Benches Centrifugal

More information

CIRCULAIRE LAMINAR AIR FLOW

CIRCULAIRE LAMINAR AIR FLOW CIRCULAIRE LAMINAR AIR FLOW Including Visionaire Touchscreen British Design & Manufacture THE MARKET LEADER IN CLEAN AIR SOLUTIONS +44(0)1278 458090 How Does Laminar Flow Work? LAMINAR FLOW AIR FILTRATION

More information

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1 Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1 Introduction Congratulations on the choice of an Australian made quality product. Labec products are manufactured, tested and calibrated

More information

CF SERIES CF100 CF200 CF300

CF SERIES CF100 CF200 CF300 CF SERIES CF100 CF200 CF300 EMBALMING SINKS WALL MOUNTS W/OPTIONAL LEG SUPPORTS REFERENCE / USER MANUAL Rev 6-10-14 IMPORTANT INFORMATION MODEL NO.: SERIAL NO.: DATE OF PURCHASE: DATE OF INSTALLATION:

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax: Steril Air mobil Owner s Manual GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : +90212 244 4401 Fax: +90212 251 7136 SAFETY WARNINGS All personnel should be alerted to the potential hazards

More information

Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in Holding Cabinets

Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in Holding Cabinets 1551 McCormick Ave. Mundelein, IL 60060 Phone: (847) 362-5500 Fax: (847) 367-8981 Toll Free Service: 1 (800) 323-9793 Carter-Hoffmann Equipment Manual Models RTB201, RTB202 & RTB282 RTB Series Roll-in

More information

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS Prepared for the: RPIC/SLCan Sustainable Labs Regional Workshop Presented by: THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY

More information

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL SSCOR/board SUCTION FOR THE EMS VEHICLE SSCOR, INC. 11064 Randall Street Sun Valley, CA 91352 USA Telephone +1-818-504-4054 800-434-5211 Fax +1-818-504-6032

More information

CBC s Inspection Findings and Possible Remedies Thereto

CBC s Inspection Findings and Possible Remedies Thereto CBC s Inspection Findings and Possible Remedies Thereto Contents of this Presentation This presentation contains examples for findings which CBC has identified during the inspection of GMP / biosafety

More information

INCREASE YOUR LAB EFFICIENCY

INCREASE YOUR LAB EFFICIENCY 1 INCREASE YOUR LAB EFFICIENCY Titan Small Portable Vertical Laminar Flow Clean Air Cabinets Scandinavian by Design 2 We have the cabin et for you for w hatever k ind of protectio n you req uire! Compact

More information

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual VACUUM OVEN Model: VPX9-2 Installation and Operation Manual Sheldon Manufacturing, Inc. P.O. Box 627, 300 N 26 th Avenue, Cornelius, Oregon 97113 EMAIL: tech @ Shellab.com; www.shellab.com 1-800-322-4897

More information

SCIF SOP for BSL 2 samples on Aria3

SCIF SOP for BSL 2 samples on Aria3 Date Last Modified: July 2, 2015 Author: David Gravano SCIF SOP for BSL 2 samples on Aria3 Overview of BSL-2+ Sorting Area and Procedures: This document aims to provide a description of the facility, instrumentation,

More information

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science LaboGene SCANdinavian by design. ORION ALMOST Rocket Science Safety Class 2 100% exhaust Probably the best Class 2 with 100% exhaust for work with animal handling or high concentrations of organic solvents

More information

Models 1839 Forma Laminar Airflow Workstation Class 100 Operating and Maintenance Manual Rev. 6

Models 1839 Forma Laminar Airflow Workstation Class 100 Operating and Maintenance Manual Rev. 6 Visit us online to register your warranty www.thermoscientific.com/labwarranty Models 1839 Forma Laminar Airflow Workstation Class 100 Operating and Maintenance Manual 7001839 Rev. 6 Preface A printed

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL CHIP WARMERS MODELS: 500-CW 700-CW 500-CW-EX (New 2014) 700-CW-EX (New 2014) INSTALLATION & OPERATION MANUAL For additional information on WITTCO or to locate an authorized parts and service provider in

More information

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products 1.0 PURPOSE The purpose of this document is to provide specifications for maintaining

More information

User Manual / Installation Instructions

User Manual / Installation Instructions User Manual / Installation Instructions Outdoor Refrigerator MODEL: L24REF Lynx Professional Grills 5895 Rickenbacker Rd., Commerce, CA 90040 Service: (888) 289-5969 Tel: (323) 838-1770 Fax: (323) 838-1778

More information

This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials.

This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials. CBS-SOP-016-18 Effective Dec 2018 Author: A. Holliss Purpose This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials.

More information

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations LABORATORY EQUIPMENT Fume Hoods Class II Biological Safety Cabinets Carbon Filtered Enclosures Ventilation Stations HEPA Filtered Safety Enclosures Clean Benches Glove Boxes Lab Animal Research Stations

More information

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet ALMOST Rocket Science FORTUNA Clean Air Cabinet Vertical Laminar Flow Cabinet FORTUNA ALMOST Rocket Science Advanced design for a clean working environment In your daily work with the Fortuna, you will

More information

Models: 1828 and and 1846

Models: 1828 and and 1846 Models: 1828 and 1829 1845 and 1846 Forma Laminar Airflow Workstation Class 100 Operating and Maintenance Manual Manual No: 7011845 Rev. 4 Model 1828 and 1845 Series Read This Instruction Manual. Failure

More information

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection Part of Thermo Fisher Scientific Advanced Operator and Product Protection Thermo Scientific precision-engineered

More information

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies Medical Biological Research & Technologies DNA/RNA UV-cleaner box UVT-B-AR Operating Manual Certificate for versions: V.3AA V.3AB V.3AD V.3AE V.3A04 Contents 1. Safety P recautions 2. General Information

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL CBFT SERIES CORRECTIONAL HEATED HOLDING CABINETS INSTALLATION & OPERATION MANUAL MODELS: CBFT CBFTHS ML-152028-0000Z ML-152029-0000Z VULCAN 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP,

More information

Use and Care Guide. Over the Patient Units and Swing Mount Units

Use and Care Guide. Over the Patient Units and Swing Mount Units Over the Patient Units and Swing Mount Units Table of Contents Page General Information 2 Operation 3-5 Dental Unit Adjustments 6-10 Cleaning, Disinfecting and Sterilization 11-12 Maintenance 13-15 Page

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL VCD & VCW SERIES CHIP WARMERS MODELS: VCD22* ML-138037 VCD44 ML-138069 VCW26 VCW46 *Formerly VCD5 VULCAN 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC

More information

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE THE HOTTEST MACHINES ON ICE CORNELIUS INC www.cornelius.com IMPORTANT: TO THE INSTALLER. It is the responsibility of the Installer to ensure

More information