Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing
|
|
- Shannon Payne
- 6 years ago
- Views:
Transcription
1 Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing
2 eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering company in the field of electrical heat tracing. Our rapidly growing company is characterised by our insistance on the highest quality, whilst using over 40 years of experience to provide the most flexible, optimised solutions. eltherm's clear commitment to Germany as a production location underlines the philosophy of supplying heat tracing solutions at the highest level, individually tailored to the customer's requirements. As an engineering company with our own development and production of heating cables, heating hoses, heating mats and jackets, measuring and control technology and accessories, we are one of the leading manufacturers of electric heat tracing. In addition to frost protection and temperature maintenance up to 1000 C, eltherm is the expert partner for complete system solutions right up to heating entire chemical and other industrial plants. We have proved our expertise and effectiveness in various areas of application, such as the oil and gas industry, in power plant construction and the automotive and food industries. Our product portfolio comprises: Heating cables and heating tapes Self-regulating heating tapes Flexible heated hoses Heating mats and heating jackets Special heating systems, like drum heating, rail and points heating, vessel and container heating Heat tracing solutions for hazardous areas Measurement and control technology Suitable accessories Heating Tapes for Sensitive Surfaces, Ready-to-Use Our factory terminated heating tapes for sensitive surfaces are suited for the heating of apparatus, technical equipment and installations made of glass, quartz or ceramic for laboratory applications. Their minimal dimensions enable close tracing. Our portfolio encompasses highly flexible heating tapes from temperatures around 260 C up to highest temperatures of 900 C. (If you plan to use the heating cable on metal and at an operating temperature in excess of 650 C, please consult our project engineers.) The preferred use of the heating cable is in a dry, non-corrosive environment. The factory terminated heating tape ELW- VA is not sensitive to rough surfaces and also suitable for use in corrosive environment. Advantages: Factory terminated Single end connection Highly flexible Surface-friendly (except ELW-VA) Small bending radius Easy to assemble Moisture proof To find out more visit 2 Ready-to-use Heat Tracing Solutions for Laboratory Applications
3 Electronic Temperature Controller, type ELTC/L-15 The plug-in ELTC/L-15 specially developed for laboratory applications is a controller with a digital display in a stable desktop housing. It was developed for applications, such as maintaining a constant temperature, heating up and controlled cooling in laboratories and technical centres, and is characterised by its simple operation. Thanks to its integrated rampmode functionality, it enables specific heating and defined cooling with counter heating in order to prevent too fast a cooling of the heated components. On the back, there is a mains lead for direct connection to a socket, a built-in socket for connection of ready-made heating tapes and one built-in socket each for connection of either a Pt100 or a type K thermocouple. It can also be used to operate heating jackets or heated hoses. Fields of application: Constant use in laboratories and technology centres Applications in the high-temperature field Advantages: Direct connection to the socket Direct connection of heating tapes, heating jackets or heated hoses Built-in socket for Pt100 in 2-wire and 3-wire connection or type K thermocouples LED display operable down to -25 C Programmable 0 to +999 C Connects 10 A resistive load with hybrid relay Operating voltage: VAC / 50/60 Hz Rampmode functionality Function: The temperature measured with a Pt 100 temperature sensor or thermocouple type K is processed by a micro controller and displayed. After having evaluated the actual and preset values, the appropriate output relays are switched, depending on the configuration. The new ELTC/L-15 desk-top controller is also suitable for operation with heating jackets and heated hoses. For To find more out information more visit visit Phone: +49 (0) /
4 Technical Information Type ELTC/L-15 Data Operating voltage 230 V AC +/- 10% Power consumption Switching capacity relay 1 Max. 5 W 10 A contact (heating) Operating temperature -25 to +55 C Storage temperature -30 to +60 C Display range -50 to +999 C Adjustable range 0 to +950 C, configurable Sensor connection Pt100 2-wire, 3-wire, and type K thermocouple Rampmode functionality for rising and falling temperature, configurable Display LED, red Protection IP 20 Dimensions [WxHxD]: 125 x 70 x 180 mm Type Designation Art. No. ELTC/L-15 Temperature controller up to 999 C, desk-top device with rampmode functionality Wiring diagram 3- and 4-pole ELTC/L Tracer and display: It is possible to use three types of sensors, either Pt100/2-wire, Pt100/3-wire or type K thermocouples. Optional display of C or Fvalues. In case of use of a Pt100/2-wire unit the actual temperature value can be corrected. Range +/- 10K or +/-18F, respectively. In case of use of a Pt100/3-wire unit the temperature is automatically corrected. Also suitable for use with ELTF-PTEx 1 and 2 sensor. Relay configuration: relay 1: regulator Thermocouple Typ U Rampmode functionality: Specific heating-up and defined cooling with counter heating to avoid rapid cooling of the heated components. T ( C) Ready-to-use Heat Tracing Solutions for Laboratory Applications
5 Heating Tape, for Sensitive Surfaces The factory terminated heating tape ELW-GN with E-glass insulation is suitable for trace heating of apparatus, appliances and systems in a non-corrosive environment and its preferred use is for glass devices and systems with sensitive surfaces. Technical Information Type ELW-GN to 260 C Data Insulation (1) PTFE Protective braid(2) Cu nickel plated Outer jacket (3) Textile e-glass Nominal voltage 230 V Output Approx. 50 W/m* Operating temp. max. 260 C Dimensions (WxH) Approx. 25 x 6 mm Bending radius flat min. 10 mm Installation temp. min. -60 C Moisture proof Yes Connection 1.2 m, with plug Protection class I Standards Manufactured Final inspection DIN VDE 0253 DIN VDE 0721 T411 2,5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you Type ELW-GN to 260 C For more information visit Phone: +49 (0) /
6 Heating Tape for Corrosive Environments The factory terminated heating tape ELW-VA is suitable for trace heating of apparatus, appliances and systems in a corrosive environment. The minimal dimensions of the heating tape enable close tracing. This heating tape is not sensitive to rough surfaces. Technical Information Type ELW-VA to 260 C Data Insulation (1) PTFE Protective braid (2) / SS 304 Nominal voltage 230 V Output Approx. 50 W/m* Operating temp. max. 260 C Dimensions Approx. 10 x 5 mm (W x H) Dimensions sleeve 32 x 16 x 65 mm (B x H x L) Bending radius, flat, min. 32 x 16 x 65 mm (W x H x L) Installation temp. min. -30 C Moisture proof Yes Connection 1.2 m silicone cable, with plug Protection class I Standards Manufactured Final inspection DIN VDE 0253 DIN VDE 0721 T411 2,5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. 2 1 Glass fibre spacers Type ELW-VA bis 260 C 6 Ready-to-use Heat Tracing Solutions for Laboratory Applications
7 Heating Tape for Maximum Flexibility It is used to heat up glass, quartz or ceramic devices and systems in a non-corrosive and dry environment. The tape is highly flexible, does not damage the surfaces and is suitable for high output requirements. The heating tape should be protected mechanically and adjacent metallic parts should be integrated in the electrical protection measures. Technical Information Type ELW-H bis 450 C Data Insulation (1) E-glass textile Outer jacket (2) E-glass textile Nominal voltage 230 V Output Approx. 250 W/m* Operating temp. max. 450 C Dimensions (W x H) 30 x 5 mm Bending radius flat min. 10 mm Installation temp. min. Not restricted Moisture proof No Connection 1.2 m silicone cable, with plug Protection class Is specified by installation. Standards Manufactured Final inspection DIN VDE 0721 T2 DIN VDE 0721 T411 1,5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. 1 2 Type ELW-H bis 450 C For more information visit Phone: +49 (0) /
8 Heating Tape Robust, for Higher Temperatures This factory terminated heating cable is ideally suited for trace heating of apparatus, appliances and systems in a non-corrosive and dry environment. The heating tape is highly flexible, does not damage the surfaces and is suitable four high output requirements. The braiding provides protection against mechanical damages and can be integrated in the electrical protection measures. Technical Information Type ELW-HS to 450 C Data Insulation (1) E-glass textile Protective braid (2) / SS 304 Outer jacket (3) E-glass textile Nominal voltage 230 V Output Approx. 250 W/m* Operating temp. max. 450 C Dimensions (W x H) 30 x 5 mm Bending radius flat min. 10 mm Installation temp. min. Not restricted Moisture proof No Connection 1.2 m, with plug Protection class I Standards Manufactured Final inspection DIN VDE 0721 T2 DIN VDE 0721 T411 1,5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you Type ELW-HS to 450 C 8 Ready-to-use Heat Tracing Solutions for Laboratory Applications
9 Heating Tape for Highest Output The preferred use of the heating cable is for glass, quartz or ceramic devices and systems with the highest output requirements in a dry environment. Single end connection and high flexibility simplify assembly. The heating tape must be installed touch-protected. If you plan to use the heating cable on metal and at an operating temperature in excess of 650 C, please consult our project engineers. Technical Information Type ELW-Q to 900 C Data Insulation (1) Quartz textile Outer jacket (2) Quartz textile Nominal voltage 230 V Output 350 W/m* Operating temp. max. 900 C Dimensions (WxH) Approx. 35 x 6 mm Bending radius flat min. 20 mm Installation temp. min. Not restricted Moisture proof No Connection 1.2 m, with plug Standards Manufactured Final inspection DIN VDE 0721 T2 DIN VDE 0721 T2 1,5 kv AC 1 min *Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers we will be pleased to advise you. 1 2 Type ELW-Q to 900 C For more information visit Phone: +49 (0) /
10 Order Numbers Heating Tapes, Pre-assembled Designation Heated length (m) Nominal output (W) max. temp. 100 C Art. No. Nominal output (W) max. temp. 150 C Article number Nominal output (W) max. temp. 200 C Art. No. ELW-GN 0,6 0, ELW-GN 1,1 1, ELW-GN 1,7 1, ELW-GN 2,4 2, ELW-GN 3,0 3, ELW-GN 4,2 4, ELW-GN 5,4 5, ELW-GN 6,0 6, ELW-GN 7,0 7, ELW-GN 10,0 10, ELW-VA 0,6 0, ELW-VA 1,1 1, ELW-VA 1,7 1, ELW-VA 2,4 2, ELW-VA 3,0 3, ELW-VA 4,2 4, ELW-VA 5,4 5, ELW-VA 6,0 6, ELW-VA 7,0 7, ELW-VA 10,0 10, Designation Heated length (m) Nominal output (W) Art. No. ELW-H-0,50 0, ELW-H-0,70 0, ELW-H-1,00 1, ELW-H-1,50 1, ELW-H-2,00 2, ELW-H-2,50 2, ELW-H-3,25 3, ELW-H-4,00 4, ELW-H-5,00 5, ELW-H-6,30 6, ELW-H-8,00 8, ELW-HS-0,5 0, ELW-HS-0,7 0, ELW-HS-1,0 1, ELW-HS-1,5 1, ELW-HS-2,0 2, ELW-HS-2,5 2, ELW-HS-3,25 3, ELW-HS-4,0 4, ELW-HS-5,0 5, ELW-HS-6,3 6, ELW-HS-8,0 8, Designation Heated length (m) Nominal output (W) Other lengths available on request. Resistance tolerance +/- 5%. All power details are nominal power at +20 C. Length tolerance ± 2 %, max. ± 0.25 m. Art. No. ELW-Q 0,6 0, ELW-Q 0,7 0, ELW-Q 1,0 1, ELW-Q 1,5 1, ELW-Q 2,0 2, ELW-Q 2,5 2, ELW-Q 3,0 3, ELW-Q 4,0 4, ELW-Q 5,0 5, When being laid, the cables must not touch each other or cross. Fuse protection with FI 30 ma must be provided. The heating tapes must be operated only with control. Observe the IEC , EN standards. 10 Ready-to-use Heat Tracing Solutions for Laboratory Applications
11 Order numbers controllers and accessories Fig. Type Designation Art. No. ELTC/L-15 Electronic temperature controller, in stable desk-top housing, with rampmode functionality, incl. built-in sockets for connecting mains cables, heating tape and Pt100 or type K thermocouples ELTF-PT.3* Pt100, 2-wire, 5 x 50 mm, mat.: , connecting cable 3 m, with 3-pole plug, fluoropolymer insulation, white, braid 2 x 0.35 mm², deployment temperature C ELTF-Te.10* Thermocouple NiCr-Ni (Typ K), class 1 Jacket element diameter 1.5 x 100 mm, plug type K, outer jacket Inconel with adapter sleeve, connecting lead 5.0 m, plug type K, sheathing fluoropolymer/silicone, crosssection 2 x 0.22 mm² Cable plug 3+PE, round, 400 V/16 A, with cable strain relief PG Diode plug For Pt100, 3-pole Cable plug For thermocouple type K Fixing material ELB m glass silk adhesive tape, 12 mm, 140 C ELGG-02 Glass woven tape 50 mm wide, roll of 100 m, max. temperature resistance: 350 C ELGG-04 Glass woven tape 70 mm wide with green marker thread in the middle, roll of 100 m, max. temperature resistance: 800 C, melting point 1,200 C ELB-11 Textile glass hose, Ø = 2.0 mm, natural *additional thermocouples available on request. For more information visit Phone: +49 (0) /
12 Your local contact: eltherm GmbH Headquarters / Production site Ernst-Heinkel-Straße 6-10 D Burbach, Germany Phone +49 (0) 27 36/ Fax +49 (0) 27 36/ info@eltherm.com Web Subject to change innovations in heat tracing
Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q
Documentation Glass -/quartz insulated Heating Cable Factory terminated Type: ELK-H, -HS, -Q ELW-H, -HS, -Q 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of
More informationHeating Mats and Jackets. innovations in heat tracing
Heating Mats and Jackets innovations in heat tracing The eltherm GmbH Solutions with electrical heat tracing systems eltherm GmbH is an international operating company specialising in the field of electrical
More informationDocumentation. Parallel Heating Cable. Type: ELP
Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant
More informationTemperature Control and Monitoring. innovations in heat tracing
Temperature Control and Monitoring innovations in heat tracing Table of Contents Overview 4-5 Type Ex-Box REG/DIS Type Ex-Box REG/LED Temperature Controller for Hazardous Areas Temperature Controller for
More informationElectrical Heat Tracing in Hazardous Areas. innovations in heat tracing
Electrical Heat Tracing in Hazardous Areas innovations in heat tracing Table of Contents Introduction 3 1. Heating Cables Type ELSR-N Self-regulating Heating Cable up to 80 C 4-5 Type ELSR-LS Self-regulating
More informationHeating Cables and Tapes. Technology. Constant wattage tapes
Heating Cables and Tapes Technology Heating cables and tapes are one of the most versatile product lines in the Isopad range. Available in a vast array of technologies, the Isopad range is surpassed by
More informationHot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological
Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution
More informationinnovative heating solutions
innovative heating solutions heatcart High density cartridge heater heatcoil Coil heater heatsens Temperature sensor Diameter Length Surface Load Sheath temperature 2,8 32 mm max. 3000 mm max. 480 V max.
More informationProduct Information Motor and machine protection
- Basic information The REISSMANN Sensortechnik heater bands were specifically designed for the electric motor industry. These heater bands are delivered as a finished product, in various combinations,
More informationAKOCABLE Heating Cable Solutions Electrical Tracing
AKOCABLE Heating Cable Solutions Electrical Tracing www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer
More informationAdvantages / Characteristics
Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg
More informationElectrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex)
Electrically Heated Sample Lines Type 3/4/5-N/M/H (Ex), PSP 4M(-W), Type 3/4/5-5/30/50/80/100/120 (Ex) Instruction Manual Version 1.00.01 Table of Contents 1 General information... 5 2 Declaration of conformity...
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationDESIGN GUIDELINES. THERMAL building SOLUTIONS
DESIGN GUIDELINES XL-Trace LSZH Self-Regulating Heating Cables for Pipe Freeze Protection Systems THERMAL building SOLUTIONS WWW.PENTAIRTHERMAL.COM Pipe Freeze protection system overview SBS Control Panel
More informationANTI-CONDENSATION HEATERS
Anti-condensation heaters prevent the occurrence of condensation in electric plant and equipment such as electric motors and generators. Their compact design facilitates easy installation, even in small
More informationF1202 TRACE HEATING. Road & Ramp
Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.
More informationPolymer solutions Heating mat EM2-CM
1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly
More informationTechnical Databook for Industrial Heat-Tracing Systems 2006/2007
R Technical Databook for Industrial Heat-Tracing Systems 2006/2007 www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the leading brands in industrial
More informationeltherm MEASUREMENT AND CONTROL TECHNIQUE
eltherm MEASUREMENT AND CONTROL TECHNIQUE eltherm competent in measuring, controlling, monitoring and indicating eltherm Elektrowärmetechnik GmbH is the specialist of electrical heat tracing systems. All
More informationTechnology. Heating Panels ZIEGLER ENGINEERING. Silicone heating panel (200 C)
Technology Silicone heating panel (200 C) Isopad silicone panels are fully waterproof and suitable for applications up to 200 C. Formed by encapsulating a resistive heating element between two layers of
More informationHeating elements for the packaging industry Proven solutions for packaging!
Heating elements for the packaging industry Proven solutions for packaging! Since the foundation in 1973 hotset has developed and produced heating elements and since then they have been on an expansion
More informationtempline electrically heated hoses with with system system options options
electrically heated hoses with with system system options options Economical Flexible Optimum Ready for use Reduce your energy by up to 30 % in comparison with conventional systems Extremely bendable in
More informationAKOCable Heating Cable Solutions Electrical Tracing
Heating Cable Solutions Electrical Tracing HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer cover Used in long
More informationeltherm Your EHT Turnkey Solutions Provider innovations in heat tracing
eltherm Your EHT Turnkey Solutions Provider innovations in heat tracing eltherm GmbH Your reliable EHT solutions provider eltherm GmbH is an international operating company specialising in the field of
More informationTechnology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design
Technology Metal drum heater design Drum H eaters Isopad offers a range of drum and base heaters that provide a reliable way to reduce viscosity, protect stored product from frost and enable product removal.
More informationConductive Leakage detectors of the Leckstar range
Conductive Leakage detectors of the Leckstar range with electrode and relay Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49 6325 6396 www.jola-info.de
More informationCoil Heaters. Design Features: Typical Applications: Coil Heaters
Coil Heaters INTRODUCTION Durex coil heaters feature continuous operating temperatures up to 1200 F (649 C). Rapid heating and cooling occur, due to the low mass construction. All heating elements are
More informationTechnical Databook for Industrial Heating Systems
Technical Databook for Industrial Heating Systems R 2003 / 2004 Edition www.tycothermal.com Tyco Thermal Controls brings together the knowledge, expertise, products and services of the five leading brands
More informationtempline electrically heated hoses with with system system options options
templine electrically heated hoses with with system system options options Economical Flexible Optimum Ready for use Reduce your energy by up to 30 % in comparison with conventional systems Extremely bendable
More informationSafety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)
Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection
More informationEnvironmental simulation chamber for complex alternating climate profiles
MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationTechnical Handbook
Technical Handbook 2010 2012 Smart heat for comfort and safety Smart heat for comfort and safety As the world leader in heat-tracing systems, Tyco Thermal Controls has the system that you need from pipe-freezing
More informationMobile measurement technology for HV components
Mobile measurement technology for HV components Also for AD and PT measurement modules! www.csm.de www.sab-worldwide.com CONTENT page The companies................................................................................
More informationHeaters for. Hot Runner Systems. COIL Heaters l MICRO TUBULAR COIL Heaters l. The first choice, to last...
Heaters for Hot Runner Systems COIL Heaters l MICRO TUBULAR COIL Heaters l HIGH PERFORMANCE HEATERS FOR MACHINE NOZZLES l TUBULAR Heaters The first choice, to last... 1 Coil Heaters Coil heaters are an
More information...just the right thing for everyone - individually adapted
...just the right thing for everyone - individually adapted Hellmich has been developing clever solutions for dedusting and flue gas cleaning, for pipelines and apparatus engineering for over 45 years.
More informationDrexan Energy Systems Inc.
Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING
More informationLABOKLAV. Autoclaves Made in Germany
LABOKLAV Autoclaves Made in Germany 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible and environmentally
More informationHYGROPHIL H process hygrometer
HYGROPHIL H 4230-10 process hygrometer Continuous humidity measurement in industrial processes. For very high demands in terms of being resistant to corrosion and dirt. Particularly suitable for cases
More informationConstant climate chamber with ICH-compliant illumination
KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert
More informationwww
HettCube INCubatORS AND COOLED INCubatORS sustainable. ERGONOMIC. HIGH QUALITY. www.hettichlab.com THE HettCube RANGE GET THE MOST OUT OF YOUR INCubatORS. ENVIRONMENTALLY FRIENDLY, ECONOMICAL AND WELL
More informationTemperature Sensor TRG Original Installation Instructions English
Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationDomestic Hot Water Application manual
Document Electrical Heating category Product name Domestic Hot Water Application manual 90% of the Legionella bacteria dies within the first 2 min at 60 C Let Danfoss do the work Index Danfoss Group is
More informationCYLINDER PLASTICS CERAMIC BAND HEATERS. Main technical characteristics: Mechanics. Electrics
CERAMIC BAND HEATERS These heaters are made up of a spiral in NiCr 80/20 or FeCrAl alloy inserted in steatite modular elements, while the outer casing is made of sheet Alusi or, upon request, stainless
More informationREF. Infrared Radiation Systems
Infrared Radiation Systems REF By quoting the REF/250 or REF/125 construction set designations and the heater type required, the REO/250 and REO/125 reflecrs are fitted with the FSR, FSM, HFS, HSR, HTS
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater
More informationEnergy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation
Energy Division CSJT MV cold shrinkable joint for 3-core cables CSJT MV cold shrinkable joint for 3-core cables Features Pre-expanded, single piece silicone rubber joint body with high mechanical expansion
More informationRotary Tube Furnaces
, Operating instruction Rotary Tube Furnaces DiaHeat-R Vollstädt-Diamant GmbH DiaHeat-R Operating instruction page1 Inhalt: 1 General description... 3 2 Main Components... 4 3 Installation... 5 3.1 General...
More informationDrum and IBC heaters
Drum and IBC heaters 2016-11 Contents Basic information on heating industrial packaging...3 Advantages...4 Selection of the right heating mat...5 WODL series drum warmers for plastic drums and canisters...6
More informationOverload relays. General descriptions. Configuration of the front
Overload relays General descriptions Type MT, bimetal-style, overload relays are designed to protect AC circuits and motors against overloads, phase failure, long starting times and prolonged stalling
More informationGas cooler series TC-Standard+
Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control
More informationCartridge Heaters. Components. Application Guidelines
Application Guidelines Up to 1.297" Dia. Up to 60" Lengths Up to 11,500 Watts 120 and 240 Volt Up to 1400 F Max. Working Temp. Modification Available to Fit Custom Applications Type CIR cartridge heaters
More informationCERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE
Electric underfloor heating Simple to install Cheap to install Simple to regulate Safe to use Maintenance free CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE WHY CHOOSE HEATCOM? Heatcom is a leading
More informationfor relative humidity and temperature
1 861 1861P01 Duct sensor for relative humidity and temperature QFM65 Operating voltage AC 24 V Signal output DC 0...10 V for relative humidity and temperature Measurement accuracy ±3 % r. h. within the
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationConstant climate chamber with humidity
KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationDanfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10
MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting
More informationELECTRIC HEATING THERMOSYSTEM
ELECTRIC RADIANT MAT 8200E INSTALLATION AND USE MANUAL heating passion ELECTRIC HEATING THERMOSYSTEM WARNING: For the guarantee to be valid, the product must be installed and handled as indicated in this
More informationElectronic Temperature Controller 70304,
Electronic Temperature Controller 70304, 70304.2 Instruction Manual Version 1.00.01 List of content 1 General information... 4 2 Declaration of conformity... 4 3 Safety instructions... 5 4 Warranty...
More informationHeated Gas Sampling Probe PSG Basic
Heated Gas Sampling Probe PSG Basic Application The heated gas sampling probes series PSG Basic are used for continuous extractive gas analysis. They enable troublefree representative sampling of hot predominantly
More informationSnow melting for ramps, access ways, and footpaths
Snow melting for ramps, access ways, and footpaths Ice and snow on paths, loading bays, driveways, ramps, stairs and other access ways, can present a major problem causing accidents and delays. To help
More informationHEATERS & SENSORS INC. - CATALOG
HEATERS & SENSORS INC. - CATALOG Mica Band Heaters Efficient, Reliable and Economical Solution Maximum 900 ⁰F Operating Temperatures Build according to custom specifications Holes and cut-outs are available
More informationManual and installation instructions. Function. Operating phase
LADDOMAT M120 Manual and installation instructions Thermal layering Function Thanks to its design and control features, the Laddomat M120 means optimal thermal layering in storage tanks, with a low and
More informationISIS SAFETY SYSTEM Installation guide
ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly
More informationGAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for FRIFRI
GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for FRIFRI FRIFRI heating elements heating elements heating elements for chip scuttles No. 48465 Ref.
More informationComfortTile Floor Heating Systems
ComfortTile Floor Heating Systems Luxurious Warmth for Your Floors The systems are easily installed under all types of floor surfaces to provide comfortable, even floor heat. ComfortTile radiant floor
More informationToll Free:
1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the
More information50 - WMS // Straight resistance thermometers with a metal thermowell and a built-in measurement insert
50 - WMS // Straight resistance thermometers with a metal thermowell 50-WMS and a built-in measuring insert The 50-WMS product group comprises ready-to-install large and small straight resistance thermometers
More informationfor relative humidity and temperature
1 860 1860P01 Duct sensor for relative humidity and temperature QFM651 Operating voltage AC 24 V Signal output DC 010 V for relative humidity Signal output L&S Ni 1000 (passive) for temperature Measurement
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationThermo Scientific Heraeus Heating and Drying Ovens
IMLAB CENTRE D'AFFAIRES HORLOGERIE 48 RUE DES CANONNIERS 59000 LILLE Tél 03 20 55 19 11 Fax 03 20 55 20 85 www.imlab.com Thermo Scientific Heraeus Heating and Drying Ovens Quality that meets every laboratory
More informationGeberit Assisted Toilet Pre-Installation Instructions
140mm Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried
More informationBlueSpin Magnetic Hotplate Stirrer
BlueSpin Magnetic Hotplate Stirrer BlueSpin LCD Digital 7 Inch Square Magnetic Hotplate Stirrer MS7-H550-Pro 7 inch square hotplate magnetic stirrers are widely used in chemical synthesis, physical and
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/11.01 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term stable membrane filter for immersion operation in activated sludge basins or wastewater
More informationInstallation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com
Installation Guide Heating cables Pipe tracing Intelligent solutions with lasting effect Visit DEVI.com Table of Contents 1 Introduction.................... 3 1.1 Safety Instructions...............3 1.2
More informationConductivity Electrode LRG Original Installation Instructions English
Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards
More informationBraided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding
2017 Supplier of choice for Harness Components Aerospace Defence Energy Commercial Marine Motorsport Braided Sleeving Powerful Solutions for Protection Mechanical Protection Electrical Insulation Thermal
More informationSWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00
TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00 CONTENTS 1 Introduction... 3 1.1 About this manual... 3 1.2 Usage according to regulations... 3 1.3 Label... 4 1.4 Symbols... 4 1.5 Safety instructions...
More informationClimate chambers with illumination and humidity The BINDER KBWF series shines with its
KBWF series (E5.2) Climate chambers with illumination Climate chambers with illumination and humidity The BINDER KBWF series shines with its homogeneous light distribution with natural illumination from
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationDryer Systems Heat Regenerating Adsorption Dryers
Heat Regenerating Adsorption Dryers Ultradryer HRS-L 1000-13600 MAIN FEATURES & BENEFITS 15 sizes available, matching to the compressor flow capacities Energy-efficient regeneration (desorption) in countercurrent
More informationResidual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)
Residual current monitor RCM470LY/RCM475LY for TN and TT systems (AC and pulsating DC currents) TDB401003en/03.2010 Residual current monitor RCM470LY Residual current monitor for TN and TT systems (AC
More informationEnergy Saving Band Heaters
Energy Saving Band Heaters MICA BAND HEATERS l MICA NOZZLE HEATERS l CERAMIC BAND HEATERS 1 The first choice, to last... Energy Saving Ceramic Band Heaters PHP Ceramic Band heaters are available with or
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationFOR PERFECT THERMAL MANAGEMENT WORLDWIDE
FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOG 2014 2 PERFECT THERMAL MANAGEMENT PRODUCT CATALOG - STEGO, Inc. STEGO, Inc. PRODUCT CATALOG - STEGO, Inc. PERFECT THERMAL MANAGEMENT 3 INNOVATION Thermal
More information1,000W (DAP-60K: 100 W per digestion vessel)
The perfect beginner s model All the benefits at a glance Speedwave Entry Technical specifications User-friendly Quick and easy to start: the high-quality TFM TM -PTFE digestion vessels consist of only
More informationDryer Systems Heat Regenerating Adsorption Dryers
Heat Regenerating Adsorption Dryers Ultradryer HRE 0375-13600 MAIN FEATURES & BENEFITS 19 sizes available, matching to the compressor flow capacities Energy-efficient regeneration (desorption) in countercurrent
More informationCASE STUDY. Safety and system uptime in the St. Gotthard Base Tunnel
CASE STUDY Safety and system uptime in the St. Gotthard Base Tunnel Two competent partners one solution: electrical enclosure manufacturer and thermal management specialist develop a concept that withstands
More informationTechnical handbook. Temperature maintenance and frost protection systems
R Technical handbook Temperature maintenance and frost protection systems Useful instructions for the use of this technical handbook For your customers... For the worksite... COPY FAX COPY COPY The as
More informationOUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW
OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW Our expertise Our expertise Company MUCKENHAUPT & NUSSELT is a cable production company in Wuppertal, which has been successful in the market since 1926 and,
More informationELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY
ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY Gas/Oil/Water Separation Hazardous area Immersion Crude oil Air treatment Steam generators Comfort Storage
More informationProtection and Control of Solid Fuel Boilers
Protection and Control of Solid Fuel Boilers thermal relief valves thermostatic valves and pump stations draft regulators www.regulus.eu BOILER PROTECTION AGAINST OVERHEATING Solid fuel boilers may get
More informationFlow Switches. Series VHS, VKS, VH
Flow Switches Series VHS, VKS, VH Reliable - Safe - Proven! Our tried-and-tested fl ow monitoring switches for liquids are used for two basic purposes: To ensure a minimum fl ow rate, e.g. of cooling water
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm
More informationFreezer Frost Heave Prevention
Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design
More informationInfrared Modules for Industrial Processes. Heraeus Noblelight
Infrared Modules for Industrial Processes Heraeus Noblelight Carbon Twin Infrared Emitters CIR Carbon Round Tube Infrared Emitters CIR Medium Wave Infrared Emitters Fast Response, Medium Wave Infrared
More informationFOR PERFECT THERMAL MANAGEMENT WORLDWIDE
FOR PERFECT THERMAL MANAGEMENT WORLDWIDE CATALOGUE 2018 2 COMPANY PRODUCT CATALOGUE - STEGO STEGO Catalogue 2018 STEGO - PRODUCT CATALOGUE PERFECT THERMAL MANAGEMENT 3 Global presence in Thermal Management
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationInfrared Modules for Industrial Processes. Heraeus Noblelight
Infrared Modules for Industrial Processes Heraeus Noblelight Infrared Halogen Emitters NIR Infrared Halogen Emitters NIR Short Wave Infrared Emitters Fast Response, Medium Wave Infrared Emitters Medium
More information