- cooling operation - built-in heat meter - electronic circulating pumps

Size: px
Start display at page:

Download "- cooling operation - built-in heat meter - electronic circulating pumps"

Transcription

1 -PN Brine to Water heat pump with domestic hot water tank 4,6-10,9 kw with R407c refrigerant The HAUTEC series may be used in conjunction with different heat sources such as geothermal probes or geothermal collector. The HAUTEC models are for space heating and hot water generating in residential and commercial buildings. The HAUTEC heat pumps are constructed to run especially quietly. All models may be delivered for cooling in summer as option. Besides optimum economic efficiency, a maximum in residential comfort, the heat pump incorporates the new HAUTEC heat pump controller especially developed for heat pump applications. The operator has full control of all functions of his heating system. The built-in ready for use HAUTEC source and heating kits and electric heating element reduce the on site assembly costs. Hot water generation is achieved into the hot water tank under the heat pump via an internal coil heat exchanger. The compact construction method has a small footprint, using very little floor space. The heat pump has a high efficiency compressor, suction gas cooled with 2 stainless steel plate heat exchangers, one for the heating circuit and one for the source circuit. It is built on a proven Hautec chassis in a sound insulated housing. The brine- and heating circulating pumps, the hot water priority switch and the electric heating element are built-in, ready for operation. The pre-wired heat pump is controlled with weather compensation and is supplied with a separate remote control. Configuration: - The integrated domestic hot water tank below the heat pump has a volume of 200 l capable of providing 340 l at 40 C (after blending) - built-in heat pump controller with plain text display - mixing circuit control ( temperature sensor must be ordered separately) - high efficiency - built-in electric heating element - easy assembly and easy operation - built-in hot water priority switch - easy transportation in two parts - built-in circulating pump for heat circuit - built-in circulating pump for brine circuit - built-in pressure transmitter (depending on the version) - flow temperature: R407c max 65 C Optional: - cooling operation - built-in heat meter - electronic circulating pumps HAUTEC comfort heat pump controller HSC1WPC, microprocessor controlled with weather compensation. It can control up to 2 heat generators for heating and domestic hot water and optional cooling, including 1 mixing circuit. Conditions: Output related switch of first heat generator (compressor), which can be operated in two power levels and additional 2nd heat generator ( e.g. electric heating element). Digital clock with perpetual calendar, clock change summer/winter time, several adjustable clocktimer programs, separate counting of operation hours and number of starts for every heat generator, plain text display. Showing the flow and return temperature of the heating system and source entrance and exit temperatures, outside and inside temperatures. Easy handling with two buttons and error diagnostics. With the master remote control it is possible to display up to 14 temperature values. Depending on the system configuration 4-8 of these will be available for use. Optional: Radio clock module, remote control with space temperature sensor, diagnostic module for data trasmission to a PC. HAUTEC digital remote control with plain text display and space temperature sensor to adjust the time, heating mode, automatic programs, holiday program or party mode. With the remote control the main values can be read out. A button for showing error messages, operation hours and number of starts for every heat generator, flow and return temperature of the heating system, source entrance and exit temperatures, outside and inside temperatures. The technican can use it as a master remote control to get other important information such as temperature and low and high pressure of the refrigerant circuit. Page 30 of 146

2 Source -PN Brine to Water heat pump with domestic hot water tank4,6-10,9 kw with R407c refrigerant Top view Heating flow 2 Heating return 3 Source inflow 4 Source exit TS Transport bracket Front view Side view Back view Heat pump Heating 1 3 TS Heating flow Cold water Circulation Hot water Heating return PN Page 31 of 146

3 -PN Brine to Water heat pump with domestic hot water tank4,6-10,9 kw with R407c refrigerant Type PN 219K PN 225K Refrigerant R407c R407c R407c R407c R407c PN 232K PN 235K Refrigerant filling weight kg 1,05 1,15 1,25 1,40 1,50 Compressor Oil (Polyol-Ester SEZ 68) kg 0,9 1,5 1,5 1,5 1,5 Primary-source (Brine-water) x x x x x Setting-up inside / outside + / - + / - + / - + / - + / - HEATING capacity B5/W35 kw 5,6 7,6 9,5 10,7 12,8 Coefficient of performance B5/W35 5,0 5,3 5,4 5,0 5,2 HEATING capacity B0/W35 (EN 255) kw 4,7 6,4 8,1 9,1 11,1 Power consumption B0/W35 (EN 255) kw 1,04 1,38 1,70 2,00 2,39 Coefficient of performance B0/W35 (EN 255) 4,5 4,6 4,8 4,5 4,6 HEATING capacity B0/W35 (EN 14511) kw 4,6 6,3 7,9 8,9 10,9 Power consumption B0/W35 (EN 14511) kw 1,07 1,42 1,74 2,05 2,52 Coefficient of performance B0/W35 (EN 14511) 4,3 4,4 4,5 4,3 4,3 HEATING capacity B0/W50 (EN 255) kw 3,6 5,0 6,6 7,4 9,3 Coefficient of performance B0/W50 (EN 255) 3,4 3,5 3,7 3,5 3,6 Coefficient of performance B0/W50 (EN 14511) 3,3 3,3 3,5 3,3 3,4 COOLING capacity B20 (Flow16 C / Return 21 C) kw 4,6 6,6 7,9 9,8 10,7 Power consumption B20 (Flow16 C / Return 21 C) Coefficient of performance B20 (Flow 16 C / Return 21 C) EER 4,3 4,6 4,6 4,9 4,6 SOURCE minimal volume flow (at 5K) m³/h 0,73 1,01 1,30 1,44 1,75 SOURCE nominal volume flow (at 3K) m³/h 1,21 1,69 2,17 2,41 2,92 SOURCE internal pressure drop (at 3K) hpa SOURCE connection dimensions Inch SOURCE entrance brine minimal C SOURCE entrance brine maximal C SOURCE frost resistance brine C SOURCE volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 2,2 HEATING minimal volume flow (at 10K) m³/h 0,40 0,55 0,70 0,79 0,95 HEATING nominal volume flow (at 5K) m³/h 0,80 1,10 1,40 1,57 1,90 HEATING internal pressure drop (at 5K) hpa HEATING connection dimensions Inch HEATING flow temperature minimal C HEATING flow temperature temporary maximal C HEATING volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 2,2 Nominal voltage V Number of phases 1~ 3~ 3~ 3~ 3~ Frequency Hz Nominal current A 5,1 2,2 3,7 4,1 4,7 cos φ 0,9 0,9 0,7 0,7 0,7 Starting current A <30 <30 <30 <30 <30 Starting current (limited) Fuse (delay) A 20 3x16 3x16 3x16 3x20 Protection class IP 21 IP 21 IP 21 IP 21 IP 21 Sound power level (EN 12102) db(a) Measurement height mm Measurement width mm Measurement depth mm Weight kg A PN 242K All technical data were determined according to EN 255 and EN The electric heating element is to be secured depending on the power input. - 3 kw / 230V~/N/PE Fuse 1x16A - 9 kw / 400V~3/N/PE Fuse 3x16A - 18 kw / 400V~3/N/PE Fuse 3x35A As an antifreeze HAUTEC Frostcare is to be used. Other antifreezes and brines on inquiry. A change-over of the refrigerant circuit (heating / cooling) is available for all devices. Subject to technical modifications. Page 32 of 146

4 -PN Brine to Water heat pump with domestic hot water tank4,6-10,9 kw with R407c refrigerant -PN R407c with 3 years cooling circle material warranty 1 product code WP order number heating capacity [kw] -PN -PN -PN -PN -PN B5/W35 B0/W35 219K 225K 232K 235K 242K -PN-219K² 88SV219AHBPN5 5,6 4, ,- -PN-225K² 88SV2251HBPN5 7,6 6, ,- -PN-232K 88SV2321HBPN5 9,5 7, ,- -PN-235K² 88SV2361HBPN5 10,7 8, ,- -PN-242K 88SV2431HBPN5 12,8 10, ,- heat pump controller 5 and remote control ready for operation, urgent neccessary and pre-programmed heat pump controller with remote control 1.302, , , , ,- Total with controller 7.000, , , , ,- The obstructed kits for the Brine and heating circles can be equipped against surcharge with electronic pumps (see page 135/136). Surcharge for exchange of multi-level source pump against electronic source pump 270,- 270,- 270,- 270,- 270,- Surcharge for exchange of multi-level circulating heating pump against electronic circulating heating pump 270,- 270,- 270,- 270,- 270,- Accessories - (optional). Further information in the accessories list connecting kit with reinforced hoses (supplied as separate unit) HWAS01L 89WA00100H0ND 148,- 148,- 148,- 148,- 148,- Heating-cooling, refrigerant circuit switching to active cooling, inclusive controller modification (built-in and ready for operation) HWU-HK01 89HK00100H0ND 1.695, , , , ,- HWU-HK02 89HK00200H0ND HAUTEC heat exchanger for passive cooling inclusive product modification (supplied as separate unit) HPK01 89PK00100H0ND 1.477, , , , ,- HPK02 89PK00200H0ND HAUTEC heat-meter (supplied as separate unit) HWME01 89WME0100H0ND 175,- 175,- 175,- 175,- 175,- HAUTEC temperature sensor for mixing circuit control (supplied as separate unit) HMKF01 89MKF0001H0ND 25,- 25,- 25,- 25,- 25,- When ordering please use product code e.g.: -PN-235K with order number. 1) The warranty for parts of refrigerant circuit comes into effect only if the equipment is used for its intended purpose and the installation and commisioning have been examinated and approved of an authorized HAUTEC customer service technician. An extended warranty of 2 years is available (refrigerant circuit) for a surcharge of 2% on the selected equipment price. 2) Also available in 230V AC. See separate price list. Please check delivery time when ordering. 3) Source circulating pump is sufficient for e.g. HAUTEC double U pipe probes of maximum length of 50 m (each); mind the maximum pressure head. 4) For use with HELN - mind the maximum pressure head 5) The Hautec Heat Pump controller must be used with these models. More accessories may be found in the accessory section page 118 onwards. Page 33 of 146

5 HCW-PN Water to Water heat pump with domestic hot water tank 6,1 11,9 kw with R407c refrigerant The HAUTEC series may be used in conjunction with underground water as heat source. The HAUTEC models are for space heating and hot water generating in residential and commercial buildings. The HAUTEC heat pumps are constructed to run especially quietly. All models may be delivered for cooling in summer as option. Besides optimum economic efficiency, a maximum in residential comfort, the heat pump incorporates the new HAUTEC heat pump controller especially developed for heat pump applications. The operator has full control of all functions of his heating system. The built-in ready for use HAUTEC source and heating kits and electric heating element reduce the on site assembly costs. Hot water generation is achieved into the hot water tank under the heat pump via an internal coil heat exchanger. The compact construction method has a small footprint, using very little floor space. The heat pump has a high efficiency compressor, suction gas cooled with 2 stainless steel plate heat exchangers, one for the heating circuit and one for the source circuit. It is built on a proven Hautec chassis in a sound insulated housing. The brine- and heating circulating pumps, the hot water priority switch and the electric heating element are built-in, ready for operation. The pre-wired heat pump is controlled with weather compensation and is supplied with a separate remote control. Configuration: - The integrated domestic hot water tank below the heat pump has a volume of 200 l capable of providing 340 l at 40 C (after blending) - built-in heat pump controller with plain text display - mixing circuit control ( temperature sensor must be ordered separately) - high efficiency - built-in electric heating element - easy assembly and easy operation - built-in hot water priority switch - easy transportation in two parts - built-in circulating pump for heat circuit - built-in pressure transmitter (depending on the version) - flow temperature: R407c max 65 C Optional: - cooling operation - built-in heat meter - well pump wiring - electronic circulating pump HAUTEC comfort heat pump controller HSC1WPC, microprocessor controlled with weather compensation. It can control up to 2 heat generators for heating and domestic hot water and optional cooling, including 1 mixing circuit. Conditions: Output related switch of first heat generator (compressor), which can be operated in two power levels and additional 2nd heat generator ( e.g. electric heating element). Digital clock with perpetual calendar, clock change summer/winter time, several adjustable clocktimer programs, separate counting of operation hours and number of starts for every heat generator, plain text display. Showing the flow and return temperature of the heating system and source entrance and exit temperatures, outside and inside temperatures. Easy handling with two buttons and error diagnostics. With the master remote control it is possible to display up to 14 temperature values. Depending on the system configuration 4-8 of these will be available for use. Optional: Radio clock module, remote control with space temperature sensor, diagnostic module for data trasmission to a PC. HAUTEC digital remote control with plain text display and space temperature sensor to adjust the time, heating mode, automatic programs, holiday program or party mode. With the remote control the main values can be read out. A button for showing error messages, operation hours and number of starts for every heat generator, flow and return temperature of the heating system, source entrance and exit temperatures, outside and inside temperatures. The technican can use it as a master remote control to get other important information such as temperature and low and high pressure of the refrigerant circuit. Page 34 of 146

6 Source HCW-PN Water to Water heat pump with domestic hot water tank6,1 11,9 kw with R407c refrigerant Top view Heating flow 2 Heating return 3 Source inflow 4 Source exit TS Transport bracket Front view Side view Back view Heat pump Heating 1 3 TS Heating flow Cold water Circulation Hot water Heating return HCW-PN Page 35 of 146

7 HCW-PN Water to Water heat pump with domestic hot water tank6,1 11,9 kw with R407c refrigerant Type HCW PN 219K HCW PN 225K HCW PN 232K HCW PN 235K Refrigerant R407c R407c R407c R407c Refrigerant filling weight kg 1,10 1,20 1,30 1,45 Compressor Oil (Polyol-Ester SEZ 68) kg 0,9 1,5 1,5 1,5 Primary-source (Water-water) x x x x Setting-up inside / outside + / - + / - + / - + / - HEATING capacity W10/W35 (EN 255) kw 6,2 8,3 10,3 12,1 Power consumption W10/W35 (EN 255) kw 1,15 1,47 1,83 2,13 Coefficient of performance W10/W35 (EN 255) 5,4 5,6 5,6 5,7 HEATING capacity W10/W35 (EN 14511) kw 6,1 8,1 10,1 11,9 Power consumption W10/W35 (EN 14511) kw 1,16 1,50 1,87 2,20 Coefficient of performance W10/W35 (EN 14511) 5,3 5,4 5,4 5,4 HEATING capacity W10/W50 (EN 255) kw 5,4 7,0 8,8 10,2 Coefficient of performance W10/W50 (EN 255) 3,8 4,0 4,0 4,0 Coefficient of performance W10/W50 (EN 14511) 3,6 3,8 3,8 3,8 COOLING capacity W10 (Flow16 C / Return 21 C) kw 4,8 8,1 8,7 11,4 Power consumption W10 (Flow16 C / Return 21 C) Coefficient of performance W10 (Flow 16 C / Return 21 C) EER 5,2 6,6 5,4 6,4 SOURCE minimal volume flow (at 5K) m³/h 0,87 1,17 1,46 1,71 SOURCE nominal volume flow (at 3K) m³/h 1,45 1,96 2,44 2,85 SOURCE internal pressure drop (at 3K) hpa SOURCE connection dimensions Inch SOURCE entrance minimal C SOURCE entrance maximal C SOURCE volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 HEATING minimal volume flow (at 10K) m³/h 0,53 0,71 0,89 1,04 HEATING nominal volume flow (at 5K) m³/h 1,07 1,42 1,77 2,07 HEATING internal pressure drop (at 5K) hpa HEATING connection dimensions Inch HEATING flow temperature minimal C HEATING flow temperature temporary maximal C HEATING volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 Nominal voltage V Number of phases 1~ 3~ 3~ 3~ Frequency Hz Nominal current A 5,7 2,5 3,9 4,0 cos φ 0,9 0,8 0,7 0,8 Starting current A <30 <30 <30 <30 Starting current (limited) Fuse (delay) A 20 3x16 3x16 3x16 Protection class IP 21 IP 21 IP 21 IP 21 Sound power level (EN 12102) db(a) Measurement height mm Measurement width mm Measurement depth mm Weight kg A All technical data were determined according to EN 255 and EN The electric heating element is to be secured depending on the power input. - 3 kw / 230V~/N/PE Fuse 1x16A - 9 kw / 400V~3/N/PE Fuse 3x16A - 18 kw / 400V~3/N/PE Fuse 3x35A A change-over of the refrigerant circuit (heating / cooling) is available for all devices. With water-water heat pumps a water analysis is inevitably to make sure that the limit values are kept for the heat exchangers or to ascertain the necessity of an evaporator with higher resistance. The limit values are to be requested from HAUTEC. Subject to technical modifications. Page 36 of 146

8 HCW-PN Water to Water heat pump with domestic hot water tank6,1 11,9 kw with R407c refrigerant HCW-PN R407c with 3 years cooling circle material warranty 1 product code WP order number heating capacity W10/W35 [kw] HCW-PN 219K HCW-PN 225K HCW-PN 232K HCW-PN 235K HCW-PN-219K² 88WV219AHBPN5 6, ,- HCW-PN-225K² 88WV2251HBPN5 8, ,- HCW-PN-232K 88WV2321HBPN5 10, ,- HCW-PN-235K² 88WV2361HBPN5 11, ,- heat pump controller 5 and remote control ready for operation, urgent neccessary and pre-programmed heat pump controller with remote control 1.302, , , ,- Total with controller 6.761, , , ,- The obstructed kits for the Brine and heating circles can be equipped against surcharge with electronic pumps (see page 135/136). Surcharge for exchange of multi-level circulating heating pump against electronic circulating heating pump 270,- 270,- 270,- 270,- Accessories - (optional). Further information in the accessories list Connecting kit with reinforced hoses (supplied as separate unit) HWAS01L 89WA00100H0ND 148,- 148,- 148,- 148,- Well pump switch. It refers to the submersible pump (connected and ready for operation) 3) HBPA01 89BP00100H0ND 293,- 293,- 293,- 293,- Heating-cooling, refrigerant circuit switching to active cooling, inclusive controller modification (built-in and ready for operation) HWU-HK01 89HK00100H0ND 1.695, , , ,- HWU-HK02 89HK00200H0ND HAUTEC heat exchanger for passive cooling inclusive product modification (supplied as separate unit) HPK01 89PK00100H0ND 1.477, , , ,- HPK02 89PK00200H0ND HAUTEC heat-meter (supplied as separate unit) HWME01 89WME0100H0ND 175,- 175,- 175,- 175,- HAUTEC temperature sensor for mixing circuit control (supplied as separate unit) HMKF01 89MKF0001H0ND 25,- 25,- 25,- 25,- When ordering please use product code e.g.: -PN-235K with order number. 1) The warranty for parts of refrigerant circuit comes into effect only if the equipment is used for its intended purpose and the installation and commisioning have been examinated and approved of an authorized HAUTEC customer service technician. An extended warranty of 2 years is available (refrigerant circuit) for a surcharge of 2% on the selected equipment price. 2) Also available in 230V AC. See separate price list. Please check delivery time when ordering. 3) With water-water heat pumps a water analysis is neccessary. 4) For use with HELN - mind the maximum pressure head 5) The Hautec Heat Pump controller must be used with these models. More accessories may be found in the accessory section page 118 onwards. Page 37 of 146

9 -PK Brine to Water heat pump 4,6 14,0 kw with R407c refrigerant with an underbuilt domestic hot water tank and flanged separate hot water heat pump. The HAUTEC series may be used in conjunction with different heat sources such as geothermal probes or geothermal collector. The HAUTEC models are for space heating and hot water generating in residential and commercial buildings. The HAUTEC heat pumps are constructed to run especially quietly. All models may be delivered for cooling in summer as option. Besides optimum economic efficiency, a maximum in residential comfort, the heat pump incorporates the new HAUTEC heat pump controller especially developed for heat pump applications. The operator has full control of all functions of his heating system. The built-in ready for use HAUTEC source and heating kits and electric heating element reduce the on site assembly costs. Hot water generation is achieved into the hot water tank under the heat pump via a flange connected hot water heat pump HWBW K. The compact construction method has a small footprint, using very little floor space. The heat pump has a high efficiency compressor, suction gas cooled with 2 stainless steel plate heat exchangers, one for the heating circuit and one for the source circuit. It is built on a proven Hautec chassis in a sound insulated housing. The brine- and heating circulating pumps, the hot water priority switch and the electric heating element are built-in, ready for operation. The pre-wired heat pump is controlled with weather compensation and is supplied with a separate remote control. Configuration: - The integrated domestic hot water tank below the heat pump has a volume of 200 l capable of providing 340 l at 40 C (after blending) - built-in heat pump controller with plain text display - mixing circuit control ( temperature sensor must be ordered separately) - high efficiency - built-in electric heating element - easy assembly and easy operation - separate hot water heat pump - easy transportation in two parts - built-in soft starter (only type 260) - built-in circulating pump for heat circuit - built-in circulating pump for brine circuit - built-in pressure transmitter (depending on the version) - flow temperature: R407c max 65 C Optional: - cooling operation - built-in heat meter - electronic circulating pumps HAUTEC comfort heat pump controller HSC1WPC, microprocessor controlled with weather compensation. It can control up to 2 heat generators for heating and domestic hot water and optional cooling, including 1 mixing circuit. Conditions: Output related switch of first heat generator (compressor), which can be operated in two power levels and additional 2nd heat generator ( e.g. electric heating element). Digital clock with perpetual calendar, clock change summer/winter time, several adjustable clocktimer programs, separate counting of operation hours and number of starts for every heat generator, plain text display. Showing the flow and return temperature of the heating system and source entrance and exit temperatures, outside and inside temperatures. Easy handling with two buttons and error diagnostics. With the master remote control it is possible to display up to 14 temperature values. Depending on the system configuration 4-8 of these will be available for use. Optional: Radio clock module, remote control with space temperature sensor, diagnostic module for data trasmission to a PC. HAUTEC digital remote control with plain text display and space temperature sensor to adjust the time, heating mode, automatic programs, holiday program or party mode. With the remote control the main values can be read out. A button for showing error messages, operation hours and number of starts for every heat generator, flow and return temperature of the heating system, source entrance and exit temperatures, outside and inside temperatures. The technican can use it as a master remote control to get other important information such as temperature and low and high pressure of the refrigerant circuit. Page 38 of 146

10 Source -PK Brine to Water heat pump 4,6 14,0 kw with R407c refrigerant with an underbuilt domestic hot water tank and flanged separate hot water heat pump. Top view Front view Side view 1 Heating flow 2 Heating return 3 Source inflow 4 Source exit TS Transport bracket Back view Heat pump 900 TS Heating Heating flow Cold water Circulation Hot water Heating return HCW-PK Page 39 of 146

11 -PK Brine to Water heat pump 4,6 14,0 kw with R407c refrigerant with an underbuilt domestic hot water tank and flanged separate hot water heat pump. Type PK 219K PK 225K PK 232K PK 235K PK 242K PK 248K PK 260K Refrigerant R407c R407c R407c R407c R407c R407c R407c Refrigerant filling weight kg 1,05 1,15 1,25 1,40 1,50 1,55 1,65 Compressor Oil (Polyol-Ester SEZ 68) kg 0,9 1,5 1,5 1,5 1,5 1,5 2,2 Primary-source (Brine-water) x x x x x x x Setting-up inside / outside + / - + / - + / - + / - + / - + / - + / - HEATING capacity B5/W35 kw 5,6 7,6 9,5 10,7 12,8 13,7 15,9 Coefficient of performance B5/W35 5,0 5,3 5,4 5,0 5,2 5,3 5,1 HEATING capacity B0/W35 (EN 255) kw 4,7 6,4 8,1 9,1 11,1 11,9 14,3 Power consumption B0/W35 (EN 255) kw 1,04 1,38 1,70 2,00 2,39 2,46 3,14 Coefficient of performance B0/W35 (EN 255) 4,5 4,6 4,8 4,5 4,6 4,8 4,6 HEATING capacity B0/W35 (EN 14511) kw 4,6 6,3 7,9 8,9 10,9 11,6 14,0 Power consumption B0/W35 (EN 14511) kw 1,07 1,42 1,74 2,05 2,52 2,51 3,18 Coefficient of performance B0/W35 (EN 14511) 4,3 4,4 4,5 4,3 4,3 4,6 4,4 HEATING capacity B0/W50 (EN 255) kw 3,6 5,0 6,6 7,4 9,3 10,0 13,3 Coefficient of performance B0/W50 (EN 255) 3,4 3,5 3,7 3,5 3,6 3,6 3,3 Coefficient of performance B0/W50 (EN 14511) 3,3 3,3 3,5 3,3 3,4 3,4 3,1 Heating capacity HWBW-K W20/W45 kw 1,6 1,6 1,6 1,6 1,6 1,6 1,6 Coefficient of performance COP >4 >4 >4 >4 >4 >4 >4 COOLING capacity B20 (Flow16 C / Return 21 C) kw 4,6 6,6 7,9 9,8 10,7 11,5 15,2 Power consumption B20 (Flow16 C / Return 21 C) Coefficient of performance B20 (Flow 16 C / Return 21 C) EER 4,3 4,6 4,6 4,9 4,6 4,6 4,8 SOURCE minimal volume flow (at 5K) m³/h 0,73 1,01 1,30 1,44 1,75 1,90 2,28 SOURCE nominal volume flow (at 3K) m³/h 1,21 1,69 2,17 2,41 2,92 3,17 3,76 SOURCE internal pressure drop (at 3K) hpa SOURCE connection dimensions Inch SOURCE entrance brine minimal C SOURCE entrance brine maximal C SOURCE frost resistance brine C SOURCE volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 2,2 2,5 2,5 HEATING minimal volume flow (at 10K) m³/h 0,40 0,55 0,70 0,79 0,95 1,02 1,23 HEATING nominal volume flow (at 5K) m³/h 0,80 1,10 1,40 1,57 1,90 2,04 2,46 HEATING internal pressure drop (at 5K) hpa HEATING connection dimensions Inch HEATING flow temperature minimal C HEATING flow temperature temporary maximal C HEATING volume heat exchanger (water-side) l 1,1 1,3 1,7 1,9 2,2 2,2 2,5 Nominal voltage V Number of phases 1~ 3~ 3~ 3~ 3~ 3~ 3~ Frequency Hz Nominal current A 5,1 2,2 3,7 4,1 4,7 4,8 6,5 cos φ 0,9 0,9 0,7 0,7 0,7 0,7 0,7 Starting current A <30 <30 <30 <30 < Starting current (limited) A 19 Fuse (delay) A 20 3x16 3x16 3x16 3x20 3x20 3x25 Protection class IP 21 IP 21 IP 21 IP 21 IP 21 IP 21 IP 21 Sound power level (EN 12102) db(a) Measurement height mm Measurement width mm Measurement depth mm Weight kg All technical data were determined according to EN 255 and EN The electric heating element is to be secured depending on the power input. - 3 kw / 230V~/N/PE Fuse 1x16A - 9 kw / 400V~3/N/PE Fuse 3x16A - 18 kw / 400V~3/N/PE Fuse 3x35A As an antifreeze HAUTEC Frostcare is to be used. Other antifreezes and brines on inquiry. A change-over of the refrigerant circuit (heating / cooling) is available for all devices. Subject to technical modifications. Page 40 of 146

12 -PK Brine to Water heat pump 4,6 14,0 kw with R407c refrigerant with an underbuilt domestic hot water tank and flanged separate hot water heat pump. -PK R407c for heating with 3 years cooling circle material warranty 1 with separate hot water heat pump flange connected HWBW K with refrigeration R134a ready for operate with 2 years cooling circle material warranty 1 hot water temperature temporarly up to 65 C product code WP order number heating capacity [kw] B5/W35 B0/W35 -PK 219K -PK 225K -PK 232K -PK 235K -PK 242K -PK 248K -PK 260K -PK-219K² 88SU219AHBPN5 5,6 4,6 1, ,- -PK-225K² 88SU2251HBPN5 7,6 6,3 1, ,- -PK-232K 88SU2321HBPN5 9,5 7,9 1, ,- -PK-235K² 88SU2361HBPN5 10,7 8,9 1, ,- -PK-242K 88SU2431HBPN5 12,8 10,9 1, ,- -PK-248K² 88SU2491HBPN5 13,7 11,6 1, ,- -PK-260K² 88SU2601SBPN5 15,9 14,0 1, ,- heat pump controller 5 and remote control ready for operation, urgent neccessary and pre-programmed heat pump controller with remote control 1.302, , , , , , ,- Total with Controller 8.385, , , , , , ,- The obstructed kits for the Brine and heating circles can be equipped against surcharge with electronic pumps (see page 135/136). Surcharge for exchange of multi-level source pump against electronic source pump 270,- 270,- 270,- 270,- 270,- 320,- 320,- Surcharge for exchange of multi-level circulating heating pump against electronic circulating heating pump 270,- 270,- 270,- 270,- 270,- 320,- 320,- Accessories - (optional). Further information in the accessories list Kit for integration an hot water generating modul in the underfloor heating return (Supplied as separate unit) HEQ01 89EQ00100H0ND 108,- 108,- 108,- 108,- 108,- 108,- 108,- connecting kit with reinforced hoses (supplied as separate unit) HWAS01L 89WA00100H0ND 148,- 148,- 148,- 148,- 148,- 148,- 148,- Heating-cooling, refrigerant circuit switching to active cooling, inclusive controller modification (built-in and ready for operation) HWU-HK01 89HK00100H0ND 1.695, , , , ,- HWU-HK02 89HK00200H0ND 1.861, ,- HAUTEC heat exchanger for passive cooling inclusive product modification (supplied as separate unit) HPK01 89PK00100H0ND 1.477, , , , ,- HPK02 89PK00200H0ND 1.855, ,- HAUTEC heat-meter (supplied as separate unit) HWME01 89WME0100H0ND 175,- 175,- 175,- 175,- 175,- 175,- 175,- HAUTEC temperature sensor for mixing circuit control (supplied as separate unit) HMKF01 89MKF0001H0ND 25,- 25,- 25,- 25,- 25,- 25,- 25,- When ordering please use product code e.g.: -PN-235K with order number. 1) The warranty for parts of refrigerant circuit comes into effect only if the equipment is used for its intended purpose and the installation and commisioning have been examinated and approved of an authorized HAUTEC customer service technician. An extended warranty of 2 years is available (refrigerant circuit) for a surcharge of 2% on the selected equipment price. 2) Also available in 230V AC. See separate price list. Please check delivery time when ordering. 3) Source circulating pump is sufficient for e.g. HAUTEC double U pipe probes of maximum length of 50 m (each); mind the maximum pressure head. 4) For use with HELN - mind the maximum pressure head 5) The Hautec Heat Pump controller must be used with these models. 6) The HWBW K is useable only in connection with underflor heating system (min 80 square meters must be constantly opened) More accessories may be found in the accessory section page 118 onwards. Page 41 of 146

Premium. Configuration:

Premium. Configuration: Carno - Water to Water heat pump 6,1-41,9 kw with R407c refrigerant The HAUTEC Carno series may be used in conjunction with underground water as heat source. The HAUTEC Carno models are for space heating

More information

Water and ground source heat pumps 61WG kw. Heating

Water and ground source heat pumps 61WG kw. Heating SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Water and ground source heat pumps 61WG 20-100 kw Heating A new carrier unit - designed for heating Trust Carrier s expertise for your heating needs Carrier

More information

Natural geothermal energy

Natural geothermal energy Natural geothermal energy ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient. L A ++ A Scale space heating

More information

Oilon Ground Source Heat Pumps

Oilon Ground Source Heat Pumps Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source

More information

Technical data LA 60TUR+

Technical data LA 60TUR+ Technical data LA 6TUR+ Device information LA 6TUR+ Design - Heat source Outside air - Model Universal design reversible - Regulation - Thermal energy metering Integrated - Installation location Outdoors

More information

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser Vitocal 300-A, type AWC-I and AW-O.1 Product description A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser & High operational reliability,

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

Ground source heat pump range. Why Vaillant? because we can unearth the energy. Ground source heat pump range Why Vaillant? because we can unearth the energy. geotherm exclusive geotherm Your future energy supply starts at home Renewable Energy With global temperatures continuing

More information

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M.

MAKING MODERN LIVING POSSIBLE. Technical description DHP-M. MAKING MODERN LIVING POSSIBLE Technical description www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels Data sheet SI 24TE Brine-to-water heat pump with two performance levels Order reference: SI 24TE Installation location: Indoors Flow temperature max 60 C Casing, powder-coated Heat pump for heating purposes

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

BWL air heat pumps BWS brine heat pumps

BWL air heat pumps BWS brine heat pumps BWL air heat pumps BWS brine heat pumps Wolf - Heat pumps Benefits offered by Wolf heat pumps From each 1 kwh power, heat pumps generate between 3 and 5 kwh heat Free environmental energy from the ground

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 00 m /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

HIGH-POWER HEAT PUMPS. Up to 300 kw

HIGH-POWER HEAT PUMPS. Up to 300 kw HIGH-POWER HEAT PUMPS Up to 300 kw 1 2 NEW GENERATION OF HEAT PUMPS GORENJE 4 COMPLETE RANGE OF NEW GENERATION HIGH-POWER HEAT PUMPS 8 MODERN CONTROL UNIT HEAT PUMPS AIR-WATER 10 Heat pumps AEROGOR COMPACT

More information

Technical specifications

Technical specifications Technical specifications Compact p by nilan Certified for use in passive houses A single compact ventilation and ing system - five efficient features The ventilation and ing solution of the future Compact

More information

PRODUCT DATA SHEETS HEAT PUMPS

PRODUCT DATA SHEETS HEAT PUMPS PRODUCT DATA SHEETS HEAT PUMPS HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIERSAL DESIGN - MAX. FLOW TEMPERATURE 70 C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

your tree NEW TREE  for you Several facts on trees: Follow our Green Tree heat pumps Follow our Green Tree heat pumps heat pumps manufacturer Green Join the Hotjet Green Tree your tree for you Line project, let us plant By purchasing the first heat pump in the HOTJET Green Tree product

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control. Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept

More information

Heat pump range. Why Vaillant? Because we are a great source of heat pump solutions. geotherm geotherm air climavair

Heat pump range. Why Vaillant? Because we are a great source of heat pump solutions. geotherm geotherm air climavair Heat pump range Why Vaillant? Because we are a great source of heat pump solutions. geotherm geotherm air climavair Your future energy supply starts at home Renewable energy When it comes to creating the

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

WZH Ground source heat pumps

WZH Ground source heat pumps Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw

More information

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery. PRODUCT DATA COMPACT P - SERIES BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating THE VENTILATION

More information

Technical data LA 60TU

Technical data LA 60TU Technical data LA 6TU Device information LA 6TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q *** PRODUCT BULLETIN Estia Air to Water Heat Pump 5 Series w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q4 2017 *** are pleased to announce the production of the NEW Estia

More information

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the

More information

Technical data LA 28TBS

Technical data LA 28TBS Technical data LA 28TBS Device information LA 28TBS Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website 17/04/2012 CI/SFB [56] www.dimplex.co.uk ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website The information is correct at time of downloading,

More information

Type summary Albatros 2

Type summary Albatros 2 OEM Type summary lbatros 2 The lbatros 2 family is a comprehensive range of controls. It offers solutions for basic to complex heating plant. Uniform and integral operating philosophy with clear-text display

More information

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45 Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The

More information

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution! SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS DE L AIR Comfort Module 5-2 kw Choose the easy heating solution! Comfort Module: heating with Carrier system innovation Proper control of heat pumps is key to

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages

Technical Data Sheet. Brine/Water Heat Pumps 8 12kW - single phase 230V. Heliotherm Basic Comfort. Basic Comfort Advantages Technical Data Sheet Air Ground Water Brine Cooling PV-ready Modulation Brine/Water Heat Pumps 8 12kW - single phase 230V Heliotherm Basic Comfort A fully modulating Brine/Water heat pump with leading-edge

More information

Ground Source Heat Pumps

Ground Source Heat Pumps indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist indoor installation Ground Source Heat Pumps heat pumps The heat pump specialist AlphaWeb compatible Simply control your

More information

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers water cooled chillers / heat pumps and condenserless chillers COLDPACK_ cooling capacity 32,2 379,3 kw heating capacity 29,5 414,4 kw compressors scroll refrigerant R407C microprocessor MP.COM models 88

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

Technical data LA 9S-TU

Technical data LA 9S-TU Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Multi Inverter Air Conditioning Condensing Units - Summary

Multi Inverter Air Conditioning Condensing Units - Summary Multi Inverter Air Conditioning Condensing Units - Summary Model Description Nominal Max of Cooling Inverter No. Heating of (kw) Fan Condensing (kw) Coils Unit ECO18MS2 Twin Multi Inverter 5kW 5.2 6.1

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

Technical data. Danfoss DHP-L

Technical data. Danfoss DHP-L Technical data Danfoss DHP-L Heat pump with the same features as Danfoss DHP-H, but with separate hot water tank. Can reduce heating costs by more than 50 percent. Main parts... 2 Bipack contents... 3

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL t Thank you for choosing Aqua inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

Industrial cooling systems LT

Industrial cooling systems LT Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in

More information

F-H Refrigerated Dryers

F-H Refrigerated Dryers F-H Refrigerated Dryers Engineered to Save Refrigeration Dryers F-H Series refrigeration dryers are the final result of intensive research and development program. The result is the most efficient direct

More information

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~

Providing sustainable energy solutions worldwide. Installation and Maintenance Manual CTC EcoHeat V 3N~ / 230V 1N~ 162 105 30-2 2013-09-23 Providing sustainable energy solutions worldwide Installation and Maintenance Manual CTC EcoHeat 400 400V 3N~ / 230V 1N~ Removing the cooling module 1. Disconnect the cooling module

More information

S-Therm Air to Water Heat Pumps

S-Therm Air to Water Heat Pumps S-Therm Air to Water Heat Pumps AIR TO WATER HEAT PUMP Air to water heat pump Nowadays, people are increasingly focusing on the cost of heating as well as on environmental issues. Traditional heating systems

More information

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Instructions AK-PC 520

Instructions AK-PC 520 Instructions AK-PC 520 084B8012 Identification Dimensions 084B8012 Principle NZ control PI or P control RI8NM102 04-2009 ENGLISH Connections P0/Pc: AKS 32R: 1 = Black = + 2 = Blue = - 3 = Brown = s Brine

More information

GLIDER_. air cooled liquid chilled chillers / heat pumps

GLIDER_. air cooled liquid chilled chillers / heat pumps GLIDER_ cooling capacity 189,7 1613,1 heating capacity 203,1 1613,1 compressors screw refrigerant R134a fan type axial microprocessor MP.COM models 45 RC GROUP SpA C_GNR_0507 87 VERSIONS : GLIDER (R134a)

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

COOLflow 4E PRODUCT RANGE

COOLflow 4E PRODUCT RANGE COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed

More information

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer The natural fit, all-in-one Daikin Altherma monobloc heat pump for the installer Air-to-water technology Air-to-water technology Daikin Altherma monobloc Why choose Daikin Altherma monobloc? A monobloc

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The

More information

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

Air / Water Heat Pump - Compact Design Modulating 8 18 kw Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 8MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 0, 6 and 48 Fig. 1 18K Fig. 2 24K and 0K Product Data INDUSTRY LEADING FEATURES / BENEFITS A competitively priced and creative solution to design

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

Precise Temperature Control; Compact Footprint

Precise Temperature Control; Compact Footprint Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

PAC BT LOW TEMPERATURE HEAT PUMP

PAC BT LOW TEMPERATURE HEAT PUMP PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw Water-Sourced Liquid Chillers/Heat Pumps with or without Integrated Hydronic Module www.eurovent-certification.com www.certiflash.com Unit with optional hydronic module Standard unit 6WG/30WG Nominal cooling

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS Chiller units and air-water heat pumps Cooling capacity: Heating capacity: 6, to 6,6 kw 8, to 69,4 kw ENVIRONMENTALLY FRIENDLY HFC R407C PROTECTION DE L'ENVIRONNEMENT Silent and compact design Air-conditioning

More information

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES 60 TON AIR-COOLED CHILLER PA-ACCTR-60 Call us today! (800)341-4297 The 60-Ton portable chiller package features a Trane CGAM chiller unit. Trane leads the industry in providing some of the most reliable,

More information

MODULAR CHILLER. R410a R22

MODULAR CHILLER. R410a R22 Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

Ground source heat pump NIBE F1255

Ground source heat pump NIBE F1255 NIBE.EU Ground source heat pump NIBE F1255 NIBE F1255 is an intelligent, inverter-controlled ground source heat pump with integrated water heater. NIBE F1255 provides optimum savings since the heat pump

More information

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING 171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

Product Line Introduction. Karl Zhang Technical support engineer

Product Line Introduction. Karl Zhang Technical support engineer Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial

More information