1 Success Story Repair & Modification i of Competitors Oil Purification Systems 1. Repair & Enhancement of Pall HVP-900 (15 GPM) Oil Purifier 1 system. Page 2 2. Repair & Enhancement of FilterDyne (5 GPM) Oil Purifier Pages 3, 4 & 5 3. Repair of Enhancement of Enervac (15 GPM) Oil Purifier 3 total systems. Page 6 4. Ultra Vac Information. Pages 7, 8 & 9 5. Repair & Enhancement of Gulfgate (10 GPM) Oil Purifier. Page 10 Call us at because we want to help you maximize the profitability of your on-sight filtration systems.
2 I. Repair & Enhancement of Pall HVP Added Condensate Sump to prevent oil carryover from vacuum tower when foaming occurs. Customer requested this due to severe foaming and over 100 Gallons of oil hitting the ground and contaminated the top soil. 2. Added improved Vacuum Pump Lube System. Includes precision needle valve drip-oil control with lower level float shut down and alarm indication. The customer had the OEM oil lube reservoir go dry and cause the vacuum pump to fail. 3. Replaced all filters with OFS direct replacement filters. 4. Ran Stainless Steel Tubing for all connections on vacuum circuit. New Lube Reservoir with Low Level Alarm & Shutdown. New Condensate Sump to prevent foam carryover and consequent oil spills. Added High Oil Level Shutdown. Stainless Steel Tubing Installed Page 2
3 II. Repair & Enhancement of Filter Dyne 5 GPM Oil Purifier System 1 1. Rebuilt and replaced the existing failed liquid ring vacuum pump. 2. Repaired ruptured evaporator / radiator on water cooling system. 3. Improved the air inlet metering of air flow with precision needle valve and added air intake filter system. Previous system had no air intake filtration. 4. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. 5. Replaced all filters with OFS direct replacement filters. 6. Repainted and relabeled the system. Precision air intake control for vacuum regulation with air intake filter. Repaired ruptured evaporator / radiator on water cooling system Rebuilt liquid ring vacuum pump. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. Page 3
4 II. Repair & Enhancement of Filter Dyne 5 GPM Oil Purifier System Replaced the existing failed liquid ring vacuum pump with externally lubricated rotary vein. 2. Improved the air inlet metering of air flow with precision i needle valve and added d air intake filter system. Previous system had no air intake filtration. 3. Replaced existing poly plastic tubing and brass compression residential plumbing fittings with stainless steel tubing and industrial Weather Head compression fittings. 4. Replaced all filters with OFS direct replacement filters. Repair wiring i within the electrical l control panel. 6. Repainted and relabeled the system. Repair internal wiring and damaged thermo-coupler wires. Installed system lifting eye. Precision air intake control for vacuum regulation with air intake filter. Externally lubricated rotary vein vacuum pump with oil lubricator with low oil level shutdown. Replaced plastic tubing and brass compression fitting with stainless steel tubing and steel Weatherhead compression fittings. Installed gate valve for variable flow control on inlet & outlet flows. Page 4
5 II. Filter Dyne 5 GPM Oil Purifier Recommended Upgrade System 3. No electric DP Gauge with Shutdown. This design the pump will go into bypass and no oil will leave the system. Electrical Conduit is non metallic with non metallic fittings Lower Cost. We use Exterior Vinyl with internal steel with steel fittings to make an internal short go to ground. Also the conduit is more robust and does cost more. Must prime the liquid ring pump every startup with water. Must have continuous water supply for the condenser to operate and the system to be efficient. Water Sump for the liquid ring pump gets sludged up with process oil. Also dirt gets into the sump and wears out the liquid ring pump. Must remove entire top structure in order to clean it. Filterdyne uses PVC Hose on for their oil lines.??? Serious Reliability & Liability Concern Saves money but seriously this one is not good. Page 5
6 III. Repair of Enhancement of Enervac 15 GPM Oil Purifier 3 total systems. 1. Replaced Coalescer Media Filters inside the towers with permanent dispersion media permanent tdispersion i media does not thave to be changed dtherefore saving the customer from changing internal vacuum tower coalescer filters. The savings saved the customer thousands of dollars per year. 2. Removed and simplified all ¾ discharge oil plumbing and installed larger sized 1.5 discharge plumbing for improved oil flow and reduced backpressure on the pump. 3. Installed filter bypass line, installed filter differential pressure gauge & change filter light on the front control panel. 4. Repaired and modified electrical controls within the control panel. 5. Repainted and relabeled the system. Installed Permanent Dispersion Media Elements in the vacuum tower replaced coalescer elements never have to be changed again. Installed Differential Pressure Gauge and change filter light. Installed flow control bypass valve for variable flow control of inlet and outlet. Repaired electrical controls within the control panel. Removed and simplified all ¾ discharge oil plumbing and installed larger sized 1.5 discharge plumbing for improved oil flow and reduced backpressure on the pump. Page 6
7 IV. OIL FILTRATION SYSTEMS, INC. UltraVac Recommended Upgrades Electrical Conduit is non metallic with non metallic fittings Lower Cost. We use Exterior Vinyl with internal steel with steel fittings to make an internal short go to ground. Also the conduit is more robust and does cost more. Gast Rotary Vane Vacuum Pump. Very low cost pump. We stopped using them 2 years ago because of reliability problems. You can see where the customer is applying sealer to stop vacuum seal from leaking. Only 2 Bolts Hold Entire Vacuum Chamber Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern No Main Power Disconnect Must Open Door with Live Panel * Serious Safety & Liability Concern Only 2 Bolts Hold Entire Condensate Tank Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Tower is not elevated relative to the oil pump The oil pump will cavitate very easy resulting in lower vacuum settings and poor water removal rates Page 7
8 The vacuum chamber is stainless steel. Our tower in steel and internally coated. The internal coating has been working very well. Only 2 Bolts Hold Entire Vacuum Chamber Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Only 2 Bolts Hold Entire Condensate Tank Seal Seal is always breaking We have repaired several of these with a Flange Kit * Serious Reliability Concern Page 8
9 Upgraded FTI or UltraVac Dehydrator Flanges Installed on Condensate sump & Vacuum Tower 1.5 X 20 Mesh Inlet Strainer Page 9
10 V. We repair, maintain and provide performance enhancements for Gulfgate Vacuum Dehydrators. Before Repair After Repair We have many performance features to make your Gulfgate Vacuum Dehydrator much easier and lower cost to operate. 1. We replace liquid-ring or water eductors with Claw vacuum pump systems. Eliminate the need for water - only one utlitly is required, electricity. 2. We replace water cooled condensers with air cooled heater exchangers Eliminate the need for water - only one utlitly is required, electricity. 3. Note: A typical Gulfgate System requiring water will consume water at a flow rate of 5 GPM. 5 GPM running 24/7 for 365 days (1 year) = 2.63 million gallons of water consumed in 1 year. Also by eliminating i water you decrease the possible risk of electric 480 Volts. 4. Replace Coalescer Elements in Vacuum Tower with Permanent Dispersion Media (PDM) Filter Elements this eliminates the need for costly coalescer element change-out because PDM Elements never need have to be changed. They also are no viscosity limited like coalescer elements. You can process up to ISO 680 Gear Oil with PDM Elements. Page 10
VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud
VUD Vac-U-Dry Vacuum Dehydrators The optimized balance between heat, vacuum, process design and an easy, user friendly operating system for removal of water and particulate from hydraulic and high viscosity
More informationACORE Filtration Co.,Ltd provides engineering,
Oil Filtration Systems For Every Demanding Application VLF Lube Oil Purifier ACORE Filtration Co.,Ltd provides engineering, manufacturing, sales of industrial oil filtration systems, we have been striving
More informationTel: Fax: Website:
Vacuum Dehydration Oil Purification System(Oil Purifier) The water and particles contamination in lubrication, hydraulic and dielectric oils badly affect the oils performance and threaten system reliability.
More informationVUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud
VUD Vac-U-Dry Vacuum Dehydrators The optimized balance between heat, vacuum, process design and an easy, user friendly operating system for removal of water and particulate from hydraulic and high viscosity
More informationVAC-U-DRY VACUUM DEHYDRATION SKIDS
VAC-U-DRY VAC-U-DRY VACUUM DEHYDRATION SKIDS Remove Free & Dissolved Water down to 20 PPM (0.002%) Remove Free & Dissolved gasses Standard Flow range 5~60 gpm,19~225 lpm (larger units available) Visually
More informationOperations and Maintenance Manual
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE INSTALLING AND OPERATING UNIT. INSURE THERE IS ALWAYS LUBRICATING OIL IN THE FRONT FILTER LUBRICATOR FOR THE FLUID PUMP AIR MOTOR. CHECK OIL LEVEL REGULARLY
More informationVAC-U-DRY VACUUM DEHYDRATOR
VAC-U-DRY VACUUM DEHYDRATOR Remove Free & Dissolved Water down to 20 PPM (0.002%) Flow range 5~60 gpm,19~225 lpm Visually Monitor Fluid and Process through Clear Chamber Covers High Operating Vacuum and
More informationSPECIFICATIONS MODEL E859C MINI DEHYDRATOR
SPECIFICATIONS MODEL E859C MINI DEHYDRATOR 1 DEHYDRATION TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (dehydrating, de-aerating, purifying
More informationVacuum Oil Purifier (VOP) (5 Pages. June 2017)
Vacuum Oil Purifier (VOP) (5 Pages. June 2017) The best designed Vacuum Oil Purifier made, combining simple operation with higher performance, creating more value for your investment. 1. 304 Stainless
More informationCFH Series High Efficiency Filters
CFH Series High Efficiency Filters Intelligent Air Technology Save energy, dollars & protect your air system The Compressed Air Challenge, a government/ industry sponsored energy savings awareness program,
More informationPortable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700
Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700 185 Principles of Operation Contaminated oil is drawn into the Parker Portable Purification System by a vacuum of 25 In/Hg. The
More informationVacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager
INTRODUCTION The science of creating vacuum is often misunderstood and when the desired vacuum condition is not being achieved in a manufacturing setting this usually means production comes to a halt and
More informationSteele Extrusion Machinery
Steele Extrusion Machinery Vacuum System The Best in Clay Machinery Since 1889 J.C. STEELE & SONS, INC. P.O. Box 1834 Statesville, NC USA 28687 TEL: (704) 872-3681 FAX: (704) 878-0789 web site: www.jcsteele.com
More informationPhoenix C 1 GPM - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE INSTALLING AND OPERATING UNIT. INSURE THERE IS A PARTICULATE FILER ELEMENT INSTALLED IN PARTICULATE HOUSING BEFORE STARTING. With Optional Aquatrex Moisture
More informationLABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS
SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",
More informationSeries 57 WATER/OIL SEPARATORS
Series 304 WATER AND OIL IN COMPRESSED AIR SYSTEM WATER ACCUMULATION When compressing air, a compressor draws in many other substances including water vapor. The compression process causes this water vapor
More informationPhoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE INSTALLING AND OPERATING UNIT. IT IS THE CUSTOMERS RESPONSIBILITY TO WIRE UNIT WITH THE APPLICABLE ELECTRICAL CORD AND PLUG FOR USE IN HAZARDOUS DUTY ENVIRONMENTS
More informationOil-Less Rotary Screw Compressors
D15H (RS) D37H (RS) Oil-Less Rotary Screw Compressors D50H SR D75H SR Intelligent Air Technology Oil-Less Rotary Screw Compressors The CompAir range of oil-less compressors can be relied upon to deliver
More informationNew Product Introductions 2011
New Product Introductions 2011 New Product Introductions MAFH-E 15gpm Dewatering Unit Portable Filtration Systems OFS Filtration Station OFCS-OFCD Filter Carts OF7 Hand Held Filters High viscosity version
More informationIndustrial Processing Solutions
Industrial Processing Solutions Fluid power, filtration, and roll cleaning products. Innovative products and technologies. Rotating Unions & Accessories Rotary unions for water and air service ( 3 8 to
More informationSPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER
SPECIFICATIONS MODEL EHV-6000-96-38-X VACUUM OIL PURIFIER 1 DEGASSING TECHNOLOGY This proposal describes the equipment which shall be supplied by ENERVAC for a system for processing (degassification, dehydration
More informationthe condensate management specialist PURO-CT Sustainable Condensate Management CONDENSATE SEPARATORS
the condensate management specialist PURO-CT CONDENSATE SEPARATORS Sustainable Condensate Management A typical compressed air system will produce thousands of gallons of oily, contaminated condensate every
More informationCHILLER. Operator s & Installation Manual
CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com
More informationEquipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions
Dry Assembled Elbows MUST Glue when Installed Exhaust Connection P-Trap Must Be Installed to Exhaust or Warranty will be Voided AA2360 Refer to this Manual for installation Instructions 2011 Midmark Corp.
More informationSECTION STEAM CONDENSATE PUMPS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 22 23 STEAM CONDENSATE PUMPS SPEC WRITER NOTES: 1. Delete between // ---- // if not applicable to project. Also delete any other item or paragraph not applicable
More informationCondensate Management Solutions
Condensate Management Solutions Quality Condensate Management How and where is condensate formed? When air is compressed, so is the moisture it contains that, when cooled, becomes a liquid condensate and
More informationINSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump
INSTALLATION AND SERVICE INSTRUCTIONS Tuthill atlantic fluidics OSR-5, 10,15 & 20 Oil sealed liquid ring vacuum pump Vacuum & Blowers 4840 West Kearney Street Springfield, MO 65803 417-865-8715 (phone)
More informationES2000 Series. Oil / Water Separators ENGINEERING YOUR SUCCESS. mb air systems ltd
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding ES2000 Series Oil / Water Separators ENGINEERING YOUR SUCCESS. The
More informationLaboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package
System with Air Treatment Center Package Specification General The Powerex Laboratory Screw Compressor Enclosure package shall include multiple oil-free rotary screw air compressors modules and associated
More informationRMF SYSTEMS PURE POWER
RMF SYSTEMS PURE POWER VACUUM DEHYDRATION UNITS Vacuum Dehydration Units THE RMF VACUUM DEHYDRATION UNITS ARE DESIGNATED OIL PURIFICATION UNITS WHICH CAN BE APPLIED DIRECTLY TO VARIOUS TYPES OF MACHINE
More informationVacuum Pump Vacuum Pump
1 COVP28-38-46-65-106 vacuum pump Oil lubricated vacuum pump COVP is a compact oil lubricated vacuum pump series, ready for connection and operation. The main electrical motor is directly connected to
More informationLIST Price - $2, Model Number: MFD-1-27-GX-X-B-14. *Quick Delivery of Units are Subject to Prior Sales
NEW DEVELOPMENT. Quick Delivery Program Mobile Filter Cart - MFD (Delivery in 1-2 Days) LIST Price - $2,431.00 Model Number: MFD-1-27-GX-X-B-14 14 gpm flow rate for fast fluid clean-up Viscosity up to
More informationOil-Less Rotary Screw Compressors Variable Speed. Engineered to Save
D15H RS D37H RS D50H SR D75H SR Oil-Less Rotary Screw Compressors Variable Speed Engineered to Save Oil-Less Rotary Screw Compressors The CompAir range of oil-less compressors can be relied upon to deliver
More informationPHoenix-M (Mini) PORTABLE LUBE AND HYDRAULICS OIL PURIFIER OWNER/OPERATIONS MANUAL
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE INSTALLING AND OPERATING UNIT PHoenix-M (Mini) PORTABLE LUBE AND HYDRAULICS OIL PURIFIER OWNER/OPERATIONS MANUAL Rev 8 03232016KB INDEX PAGE 1 SECTION 1: Phoenix
More informationTechnical Specifications & Pricing
Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration
More informationSECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.
SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.
More informationCold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Cold Energy Saver Thermal Mass Cycling Refrigerated Air Dryers (200-1000
More informationPowerVac G Single to Twin Conversion Kit [ ]
PowerVac G Single to Twin Conversion Kit [002-1371-00] warning Motors are thermally protected with automatic reset. Unit may start without warning. Caution Vac unit weighs 375 lbs (170 kgs). Use care when
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA
More information2002 METAL FORM MFG. Form No: CCIOM/03
CELLCOOL Evaporative Cooling Module Installation Operation and Maintenance Manual PLEASE READ ENTIRE DOCUMENT BEFORE PROCEEDING WITH INSTALLATION Energy Saver has a policy of continuous product improvement
More informationSTEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationReliable Solutions in. Level Indication & Control, Sight Flow Indication, Filtration & Separation. Working Together to Deliver
Working Together to Deliver Reliable Solutions in Level Indication & Control, Sight Flow Indication, Filtration & Separation Anderson Separators Clark Steam Traps Ernst Flow Industries Enervac HYCOA Jacoby-Tarbox
More informationAtlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm
Atlas Copco Oil-sealed rotary screw vacuum pumps GVS 30-400, 35-3000 cfm Reliable general vacuum for critical applications Atlas Copco, the industry leader in compressed air solutions, has transferred
More informationMobile Transformer Oil Purification Plant
Mobile Transformer Oil Purification Plant Mobile Transformer Oil Purification Plant 1. GENERAL The necessity for regular purification of electrical insulating fluids in electrical apparatus has been recognized
More informationKey Question. What is the most important aspect to the removal and cleaning of material?
Objectives Increase plant maintenance issue awareness Understand how and where new technology can make workplace safer Ideas to discuss cleaner and more efficient Key Question What is the most important
More informationIngersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)
Ingersoll Rand Rotary Screw Air Compressors 5-15 hp (4-11 kw) A New Standard of Performance Ingersoll Rand Welcome to Ingersoll Rand s rotary air solutions, a new standard of performance. Achieve highest
More informationFM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)
www.rbmosherco.com 5902 FM 517 San Leon, TX 77539 Toll Free: 1-800-444-2207 Office: (281) 339-3382 Fax: (281) 559-1152 E-mail: sales@rbmosherco.com R.B. MOSHER CO. has been in business since 1986, providing
More informationRotary screw Air compressors. Fixed Speed 5 15HP
SEG Series Rotary screw Air compressors Fixed Speed Rotary screw Air Compressors 5 15HP Some companies are founded on hard work. Others are founded on ideals. FS-Curtis was founded on both. 1854 1857 1876
More informationCondensate Drain Valves
Innovative Compressed Air Products A Complete Line Of Drain Valves To Fit Every Compressed Air Condensate Removal Application WDV Series Condensate Drain Valves Leading Edge Technology CORPORATION Dimensions
More informationIFPM32 Internormen Fluid Purifier Systems. Maintenance manual Version 1.4
IFPM32 Internormen Fluid Purifier Systems Maintenance manual Version 1.4 Serial-no.:... Rev.-Date: 27.01.2015 Contents 1. SAFETY INFORMATION 3 1.1. Signal glossary... 3 1.2. Safety notes... 3 1.3. Intended
More informationWFH Series. High Efficiency Filters
WFH Series High Efficiency Filters Save Energy Dollars Protect Your Air System Your compressed air is contaminated! Airborne water vapor and dust are drawn into your compressor intake. The compressor adds
More informationIngersoll Rand 5-15 hp. Rotary Screw Compressors
Ingersoll Rand 5-15 hp Rotary Screw Compressors A New Standard of Performance Ingersoll Rand Achieve Highest Productivity and Lowest Total Cost-of-Ownership. Boost Your Profitability Boosting your company
More informationNitrogen Generation Systems Compressed Air Dryers
Nitrogen Generation Systems Compressed Air Dryers Balston Compressed Air Dryers Balston offers both membrane and PSA technology. Balston Membrane Air Dryers combine superior coalescing technology with
More information"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8
Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD
More informationCH250 AND CH251 CHILLERS
CH250 AND CH251 CHILLERS Operator s & Installation Manual Release Date: April 19, 2004 Publication Number: 620914801 Revision Date: May 15, 2015 Revision: G Visit the Cornelius web site at www.cornelius.com
More informationClosing procedures for above-ground pools
Closing procedures for above-ground pools Note: Carefully read this entire document before closing your pool. The following procedures are also available in video format under the «Videos» tab at www.trevi.com.
More informationVacuum Pumps and Accessories
Vacuum Pumps and Accessories www.midlandtechnologies.com Vacuum-Assist Die Casting Why Vacuum-Assist The two leading causes for rejection of high pressure castings are poor fill and excessive porosity.
More informationPZ1, PZ3 & PZ6 Installation Guide
PZ1, PZ3 & PZ6 Installation Guide PROZONE INTERNATIONAL, INC. Ozone Water Purification Systems INSTALLATION GUIDE Prozone PZ1, PZ3 and PZ6 Series Ozone Generator Systems SAFETY READ AND FOLLOW ALL INSTRUCTIONS.
More informationEV-PRO CONDENSATE SEPARATORS
EV-PRO CONDENSATE SEPARATORS SUSTAINABLE CONDENSATE MANAGEMENT The EV-Pro line of condensate separators use specially treated, adsorbent, polypropylene media, the FS-CURTIS EV-PRO Condensate Separators
More informationFixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)
Fixed Speed Rotary Screw Compressors UP6 Series - kw (5-5 hp) More Than 5 Years of Compressed Air Innovation Ingersoll Rand introduced its first air compressor in 87. Over the next 5 years, we have continued
More informationElectric Submersible Pumps
Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast
More informationCompressed air preparation Compressed air storage Moisture management. Catalog #1
Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.
More informationIndustrial. Solutions brands you trust. Product Overview
Industrial Solutions brands you trust. Product Overview Industrial Pump Applications Crane & Systems design s the most efficient and economical pumps to serve the large diversity of industrial applications
More informationEXAIR's compressed air operated Reversible Drum Vac System attaches
Pump 55 gallons in 90 seconds! Two-way pumping action! What Is The? A safe, maintenance free way to recover: Coolant Hydraulic oils Liquid spills Sludge and chips Tramp oil Waste water EXAIR s Mini allows
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE PUMP REVIEW Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationFLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.
FLOOD KING 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS. IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always be sure
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual
ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual Manual P568800 Rev 1, Mar 30, 2010 1 As the installer or operator, you should make yourself familiar with this Installation and
More informationSullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid
Sullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid Maximize energy savings Minimize costly repairs Removes condensate, protecting your equipment Drains designed for every application
More informationInstallation Instructions for. WaterMaster Series Fountains
Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly
More informationInstallation Instructions for. WaterMaster Series Fountains
Installation Instructions for WaterMaster Series Fountains Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly
More informationA AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1
A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationSEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30
SEPREMIUM 10 SEPREMIUM 20 SEPREMIUM 30 SEPREMIUM 10 SEPREMIUM 30 INDEX Useful information SEPREMIUM 10 SEPREMIUM 20 OIL/WATER SEPARATION SEPREMIUM 30 PURO MINI DISTRIBUTOR Accessories Features Exploded
More informationHYDROGEN SULFIDE REMOVAL SYSTEMS
OX120U5, OX120U10 OX120B5, OX120B10 OX120U10R & OX120U5R INSTALLATION, OPERATION & SERVICE INSTRUCTIONS HYDROGEN SULFIDE REMOVAL SYSTEMS NO MEDIA NO CHEMICALS NO WASTE PRESSURE BOOSTING SYSTEM MODELS:
More informationReve rsib le D rum Vac. Pump 55 gallons in 90 seconds! Two-way pumping action!
Reversible Drum Vac Reve rsib le D rum Vac Pump 55 gallons in 90 seconds! Two-way pumping action! MOBILE VIEW What Is The Reversible Drum Vac? A safe, maintenance free way to recover: Coolant Sludge and
More informationR 5 Central Vacuum Systems
R 5 Central Vacuum Systems R 5 Central Vacuum Systems R 5 Rotary Vane Vacuum Pumps The modular designed Busch R 5 series rotary vane vacuum pumps are single stage, air-cooled, and direct driven. This oilrecirculating
More informationtwin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)
D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm3/hr) D D D twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-1,300 Nm 3 /hr) Leading
More informationZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification
1 ZLA Series Double-stages Vacuum Transformer Oil Purifier Transformer Oil Purification ZLA series double-stage vacuum transformer oil purifier is particularly suitable for dehydration, degasification
More information2003 METAL FORM MFG. FORM NO: PCIOM/03
PRECOOLER PRE-CONDENSER EVAPORATIVE COOLERS Installation, Operation, and Maintenance Manual Energy Saver (ES) has a policy of continuous product improvement and reserves the right to change designs and
More informationKAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS
KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY ENVIRONMENT DRAIN EFFICIENCY SAFEGUARD RELIABLE COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS Level sensed
More informationPamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet M2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationPrime chiller. Inline Chiller. Instructions for Models #2645,2646
Prime chiller Inline Chiller Instructions for Models #2645,2646 Warning and Safety Instructions... Page 2 Chiller Installation... Page 3 Temperature Controller Programming... Page 5 Warranty... Page 7
More informationLocations Include: Food & Beverage. Chemical. Waste Water Treatment. Pulp & Paper. Energy, Oil & Gas
Locations Include: Memphis, TN Jackson, TN Little Rock, AR Springdale, AR Tupelo, MS Food & Beverage Chemical Waste Water Treatment Pulp & Paper Energy, Oil & Gas 1721 Corporate Avenue Memphis, TN 38118
More informationModel: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More informationPamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series
Pamphlet U2404 Mechanical Pump & Pump/ Trap GP Series GT Series Effective Processing Improves Plant Efficiency Increased productivity and product quality, plus reduced energy consumption and water treatment
More informationOIL/WATER SEPARATORS. Compressed Air & Process Filtration
DS OIL/WATER SEPARATORS Compressed Air & Process Filtration DS OIL/WATER SEPARATORS LEADING THE WAY IN AIR PURIFICATION As one of the world s leading manufacturers of compressed air purification equipment
More informationNOTE: Parts are no longer available for this tool. The manual will continue on the next page.
NOTE: Parts are no longer available for this tool. The manual will continue on the next page. ------------------------------------------------- CATALOG NO. 7628 Form No. Z21 0 Date 1-93 High Pressure Power
More informationQSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP
QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP QSV ROTARY SCREW VACUUM PUMPS QUINCY COMPRESSOR: THE LEADER IN INDUSTRIAL VACUUM TECHNOLOGY Pioneers
More informationModel: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically
More informationEFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08
EFFECTIVE: MAY, 2014 American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL 900 Blake Street Edwardsville, Kansas 66111 (913)422-3700 05/08 The American Dish Service part numbers contained in this
More informationTM Series. Induced Draft, Counter Flow Optional Accessories
ANTIFREEZE PACKAGE / RESISTANCE HEATING OPTION The antifreeze package is supplied to provide protection against freezing of standing water in the cooling tower sump due to shutdown during winter operation.
More informationFlexible Solutions for Air Quality
Flexible Solutions for Air Quality Doosan Portable Power understands the importance of clean air Clean air is essential to the safety and efficiency of countless compressed air applications. Without it
More informationDRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual
DRRRRDRY-PAK Instruction and Installation Manual IB-160 Rev. B P/N 36595 Registered by UL to ISO 9001 DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual INSTALLATION: Models DS0-00-000 through
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationWORLD CLASS 2012 PRODUCT CATALOG. Filtration and Fluid Conditioning Products. Fluid Power
WORLD CLASS 2012 PRODUCT CATALOG Filtration and Fluid Conditioning Products CONTENTS Technical Data 1 HT Cart 2 Ultimate Cart 3 T3 Totes 4 Tandem Cart 5 Ultimate Tandem Cart 6 Cube Cart 7 Drum Cart 8 Panel
More informationCBT LW MAINTENANCE GUIDE
CBT LW MAINTENANCE GUIDE PICTOGRAMS Each Signifier displayed here is specific to this User Manual. Menu Previous Advance Note Tip Example Powder Feeder Mixing Bowl Weigh Scale CBP Tanks Control Panel PSD
More informationSCFM REFRIGERATED COMPRESSED AIR DRYERS. CRN Series
10 3000 SCFM REFRIGERATED COMPRESSED AIR DRYERS CRN Series Durability Delivered Champion CRN Series refrigerated air dryers are engineered to benefit you today and tomorrow. Quality components and engineering
More informationQUINCY QGS SERIES hp
QUINCY QGS SERIES Rotary screw air compressors 40-100 hp Quincy Compressor strives to provide you with three main benefits in its air compressors, efficiency reliability and innovation. The Quincy QGS