Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40
|
|
- Elwin Benson
- 5 years ago
- Views:
Transcription
1 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination of the warranty. The fl oat-controlled condensate trap is designed for the discharge of condensate from steam, compressed air and pressure gas systems. Any other usage is not permitted. The manufacturer is not liable for damage resulting from any other usage. The user or operator bears the risk in this case. This also applies analogously to incorrect assembly, start-up, use and maintenance. 1.2 Warnings and symbols Personal risk due to escaping operating medium because of pressure, temperature and weight. Failure to comply with these warnings results in the risk of accidents. Follow the instructions in this operating manual. The operator must ensure that this operating manual and, if necessary, other relevant documents are available on site. Only trained or instructed personnel may be assigned to handling this equipment. Any mode of operation that may impair safety must be avoided. 2 General description and usage 2.1 Design of the condensate trap 1 Housing flange part 2 Housing gasket 3 Housing side part 4 Control screw 5 Housing screws 6 Screw plug 7 Protective sleeve 8 Supporting screw Picture 1: Model 1200 Model 1200-G 9 Float control assembly 10 Supporting body assembly with rotary valve and cotter pin 11 Float with fork 12 Maxosglas 13 RWG frame 14 2 Gaskets for RWG 15 RWG screws 16 Gasket 17 Gasket Picture 2: Model 1200-N: without RIFObi air venting 18 Gasket Page 1 of 7 01/2017 -Di. Subject to modifi cations
2 2.2 Operation limits of housing material (Design) For Model 1200: max. operating pressure (bar g) max. operating temperature ( C) < * * only with screw material A4-70/ 1,4571/ For Model 1200-G: max. operating pressure (bar g) max. operating temperature ( C) -10/ For Model 1200-N: max. operating pressure (bar g) 40 33,7 29,7 27,4 max. operating temperature ( C) Function limit of control unit max. line pressure in bar g Cross section Steam Compressed air IIa III IV V 2,5 3 VI VIa VII VIIIa 4,5 5,5 2.4 Discharge capacity -Di. Subject to modifications 01/2017 Page 2 of 7 Discharge capacity in kg/h 2.5 Function DN 15/20/ ,01 0,02 0,03 0,05 0,1 0,2 0,3 0,5 0,8 1 1, Pressure difference in bar (with reference to atmospheric pressure) Picture 3 Discharge capacity in kg/h DN 40/ ,01 0,02 0,03 0,05 0,1 0,2 0,3 0,5 0,8 1 1, Pressure difference in bar (with reference to atmospheric pressure) Picture 4 For the cold condensate the discharge capacity is higher because of medium temperature and density. Due to the gravity the condensate flows downwards to the lowest point, which is the condensate trap housing. In the lowest position of the float the outlet cross-section is close. Rising of the liquid level lifts the float and opens the outlet. Condensate will be discharged through the upturned immersion tube. Decreasing condensate level closes the outlet again. 2.6 Compensation line In order to get proper function, the non-condensable gas must be able to leave the housing. Due to the vertical installation, the non-condensable gas is able to leave the housing and flows into the steam/gas chamber above it, which has the same
3 pressure level. If the self-venting through the pipe must be extended, the control screw (4) can be replaced by a cutting ring screw bolt and a compensation line can be installed leading upwards. Bimetal 2.7 Automatic venting For Model 1200 and 1200-G: RIFObi-automatic bimetal venting valve (venting to interior): The valve is opened in cold conditions, e.g. during the start-up and when air comes into the steam trap during the operation. The valve is closed when only steam exists in the steam trap. See Picture 5. For Model 1200-N: without RIFObi-automatic bimetal venting valve Picture Gastight under-level float control (only for gas applications) For gas applications, a gastight under-level float control is nearly exclusively used. Consult with Rifox, if necessary. 3 Assembly 3.1 Flow Direction Vario WR Vario WL Vario SO Vario SU Picture 6 Vario-WR: Flow direction horizontal from right to left Vario-WL: Flow direction horizontal from left to right Vario-SO: Flow direction vertical from top to bottom Vario-SU: Flow direction vertical from bottom to top 3.2 Modification for a different flow direction The RIFOmat Vario is delivered according to the purchasing specification, as shown in Picture 6. It can be quickly installed on site for a different flow direction, without any problem. Hier s an Example: The RIFOmat Vario 1200 / 1200-G / 1200-N has been delivered as Vario-SU and has to be mounted as Vario-WR. Unscrew the housing hexagon nuts and remove the housing side part (3) sideways. Loosen the supporting screw (8) by unscrewing it for 1-2 full turns. Use a plastic hammer to loosen the float control assembly (9) from its conic housing seat by lightly stroking on the the supporting screw (8). Reposite the housing flange part (1) by turning it 90. Reposite the float control assembly (9), so that the tube (T) pointing vertical downwards. Screw in the supporting screw (8) with gasket (17). Tighten it with a standard ring wrench or a open jawed wrench, size 27. Tightening torque according to Section 6.6. Replace the housing gasket (2) if damaged, and mount on the lateral part of housing side part (3). Tighten housing bolts evenly crosswise. Tightening torque according to Section Modification for restricted space and horizontal flow In the case of only minimal space for the housing, which projects to the side, the housing side part (3) can be mounted towards to the front or towards the rear by repositioning the housing flange part (1) for the purpose of better maintenance or better visual inspection of a built-on reflective water level gauge, etc. 3.4 Installation The condensate trap Vario 1200 / 1200-G / 1200-N has to be screwed into a pipeline between flanges. Remove transport caps from inlet and outlet. Fitting direction: according to Picture 6. The condensate flow is in the direction of the arrow (note arrow on housing flange part (1) ). The housing is positioned to the side. The word TOP on the housing side part is at the top and must be legible horizontally. Page 3 of 7 01/2017 -Di. Subject to modifications
4 Supporting brackets: The supporting brackets are not necessary for DN15/DN20/DN25 if the pipeline is adequately supported before and after the condensate trap. Condensate traps for DN40/DN50 weight over 37 kg, ensure thus proper fixing of the pipeline in front of and behind the condensate trap. To avoid downtimes, it is recommended to install stop valves with bypass to pipeline, both in front of and behind the condensate trap. 4 Start-Up The pressure build-up and heating-up of the housing should not take place abruptly. If leakage is detected after the first inspection, the screws (4 / 5 / 6 / 8 / 15) can be fixed under consideration of the given torque moments, as given in Section 6.6. The screws can only be tightened on when the housing is unpressurized and at room temperature. 5 Observation and check The function s failure can be observed either as condensate blockage or as gas/ steam leakage. Condensate blockage can be determined by a): loosen the control screw (4) for a quarter rotation, while no condensate leakage should occur; and by b): a surface thermometer on the housing for steam applications (if necessary, please consult with Rifox). Gas / steam leakage: can be determined by an ultrasonic measuring device, and for steam applications by a surface thermometer. In case of steam leakage, open the condensate trap according to Section 6.1. Make sure that float (11) can be easily moved. If necessary, disassemble and clean the float control assembly (9). If damages/ wears are detected on parts or on the sealing surface, the complete float control assembly (9) should be replaced. 6 Maintenance / Inspection 6.1 Opening the steam trap and dismantling the float control The steam trap must be depressurized. Shut off the system securely in front of and behind the steam trap. Release any remaining pressure in the housing by loosening the control screw (4) by only a quarter turn. Dismantle the steam trap from the pipeline system. Condensate traps for DN40/DN50 weight over 37 kg, apply thus lifting device. Loosen the housing screws (5) evenly crosswise. Remove the housing side part (3). Loosen the supporting screw (8) and screw out 1 to 2 turns. With a few light strokes using plastic hammer on the front side of the supporting screw (8) to loosen the float control assembly (9) from the conic housing seat. b p v Screw out the supporting screw (8) completely. Take out the float control assembly (9). 6.2 Disassembling, cleaning and assembling the float control (Picture 7) After removing the cotter pin (p), the rotary valve (v) can be simply pulled out to the side. Clean the parts using, for example, benzine. Check the rotary valve (v) for wear along the sealing edge. If wear is detected, the support body (b) together with the rotary valve (v) must be replaced. The Picture 7 exactly leakage test must be carried out by RIFOX. During assembly ensure that the notch in the rotary valve (v) points to the punch mark on the support body (b) and the cotter pin (p) is inserted and secured again carefully. It must be possible to move the float up and down easily by hand. -Di. Subject to modifications 01/2017 Page 4 of 7
5 6.3 Installation of the float control assembly and assemble the condensate trap To install the control unit in Model 1200-N (Housing material: stainless steel), please use the delivered installation set. (Copper gasket and installation bolt). The complete float control assembly (9) is inserted into the conical housing seat with the support body. It must be ensured that the tube is positioned vertically downwards. Screw in the installation bolt with copper gasket into the thread of the supporting body and tighten it with a wrench. (Tighten torque see Sec. 6.6). Screw out the installation bolt, replace the copper gasket with a standard gasket (11). Attention: This step is only for Model 1200-N! Screw in the supporting screw (8) with gasket (17) and tighten evenly crosswise using a standard ring wrench. Tightening torque according to Section 6.6. Check the housing gasket (2), replace it it is damaged. Put on the housing flange part (1) Tighten the housing screws (5) evenly crosswise. Tightening torque according to Section RIFObi automatic venting valve for Model 1200 / 1200-G (Picture 8) Function: Startup and continuous venting takes place inward, i.e. towards the condensate side. Near the temperature of ebullition the bimetal valve closes. When the temperature drops, the bimetal valve opens. Replace the bimetal valve (10.3): Dismantle the complete float control assembly (9) as described in Section 6.1. Loosen the hexagon nut (10.5) with wrench size 5. Dismantle the Bimetal valve (10.3). Visual check the seat part of valve gate (10) and of bimetal valve (10.3) for wear (cross scoring). Replace the bimetal valve (10.3). Install the float control assembly (9) as described in Section 6.3. Picture Care and maintenance In the case of a great risk of dirt accumulation, the housing, when it is depressurized, should be rinsed thoroughly from time to time. If necessary, the float control assembly (9) should also be checked according to Section 6.2. The dirt, which has been accumulated in the housing, can be removed away by screwing off the screw plug (6). For special applications, it is advisable to install a separate upstream strainer. The float control assembly (9) usually does not to be special maintained. The maintenance depends primarily on the wear resistance of the valve gasket. See Section 6.1 and 6.2. Page 5 of 7 01/2017 -Di. Subject to modifications
6 6.6 Tightening torque Tightening Torque (Nm) Position Part Name DN15, DN20, DN25 DN40, DN50 Cu WE PTFE Cu WE PTFE Control screw Housing screw Screw plug Supporting screw RWG screw Spare parts: Only original spare parts can be used. Picture 9: Model 1200 Model 1200-G Picture 10: Model 1200-N: without RIFObi air venting -Di. Subject to modifi cations 01/2017 Page 6 of 7
7 Pos. Part Name Model 1200 Model 1200-G Model 1200-N 1 Housing flange part GP240GH EN-JS / Housing gasket Soft iron Soft iron PTFE or Housing side part GP240GH EN-JS / Control screw: G¼ (BSP) Housing screws A4-70 acc. DIN 939/ acc. DIN 939 / ISO 4032 A4-70 acc. DIN 939 / ISO Drain plug: G½ (BSP) DIN DIN DIN A4 7 Protective sleeve Supporting screw Float control assembly /1.4112/1.4301/ /1.4112/1.4301/ Complete float control with built-on /1.4112/1.4301/1.4104/ /1.4112/1.4301/1.4104/ bi-meatellic venting valve RIFObi SS-Hastelloy SS-Hastelloy Supporting body assembly with rotary /1.4112/1.4301/ /1.4112/1.4301/ valve and cotter pin Complete Supporting Structure incl rotary slide valve, cotter pin and builton /1.4112/1.4301/ /1.4112/1.4301/ RIFObi bi-metallic venting valve 11 Float with fork or or Maxosglas as per DIN 7081 as per DIN 7081 as per DIN RWG frame P265GH P265GH Gaskets for RWG poor graphite with SS Sigraflex Novaphite 15 RWG screws A4-70, DIN 938/934 A4-70, DIN 938/934 A4-70, DIN 938/ Gasket for control screw Soft iron Soft iron PTFE or Gasket for supporting screw Soft iron Soft iron PTFE or Gasket for drain plug Soft iron Soft iron PTFE or Conformity assessment The pressure equipment described is a pressure-keeping component in accordance with the Pressure Equipment Directive 2014/68/EU. DN15, DN20, DN25: according to Art. 4, Subs. 3, no CE-Mark. DN40, DN50: Conformity verified through the identifying mark: CE A detailed declaration of conformity assessment according to PED is available as separate document. Please request if necessary, if not attached. Page 7 of 7 01/2017 -Di. Subject to modifications
Model: 1100 Float-Controlled Condensate Trap, PN 25
1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationOperating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage
Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination
More informationModel: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100
1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead
More informationOperating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use
1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically
More informationGESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45
GESTRA Steam Systems DK 45 EN English Installation Instructions 818676-00 Steam Trap DK 45 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED
More informationINSTALLATION, OPERATION
OM No. E-ER25-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ER 25 SERIES MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku
More informationOperating and installation instructions
Steam traps for quick assembly/disassembly CONA Universal/ CONA Connector ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 604) ANSI300 - with Universal-Flange 2 x 3/8 UNC thread (BR 622) ANSI300
More informationGESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50
GESTRA Steam Systems BK 15 Installation Instructions 810682-02 Steam Trap BK 15, DN 40-50 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure
More informationINSTALLATION, OPERATION
OM No. E-ES8N-230627 en INSTALLATION, OPERATION and MAINTENANCE MANUAL Inverted Bucket Steam Trap MODEL: ES8N MIYAWAKI INC. Osaka, Japan Headquarter: MIYAWAKI Inc. 2-1-30, Tagawakita, Yodogawa-ku Osaka
More informationSteam Trap BK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-08 Contents Foreword... 3 Availability... 3 Formatting features in the document... 3 Safety... 3 Use for the intended purpose...
More informationLevel Electrode NRG Original Installation Instructions English
Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationSMK 22 SMK SMK SMK 22-82
GESTRA Steam Systems SMK 22 SMK 22-51 SMK 22-81 SMK 22-82 EN English Installation Instructions 810481-04 Steam Traps SMK 22, SMK 22-51, SMK 22-81, SMK 22-82 1 Contents Title Page Title page...1 Inhalt
More informationSuperKlean Washdown Products
February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT
More informationBall Float Steam Trap with Integral Spiratec Sensor and Flanged Connections
Page 1 of TI-P615-03 ST Issue IFT57 SG Iron ISO 9001 Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections Cert. No. LRQ 0963008 IFT57H DN0 (horizontal shown) DN15 (vertical shown)
More informationBK 45 BK 45-U BK 45-LT BK 46
Steam Trap BK 45 BK 45-U BK 45-LT BK 46 Original Installation Instructions 810437-07 Contents Preface...3 Availability...3 Text layout...3 Safety...3 Usage for the intended purpose...3 Basic safety notes...4
More informationMK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2
GESTRA Steam Systems MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2 Installation Instructions 810348-07 Steam Traps MK 45-1, MK 45-2, MK 45 A-1, MK 45 A-2 Contents Important Notes Page Usage for the intended purpose...4
More informationTechnical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT
Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT
More informationGESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME
GESTRA Steam Systems BK 37 BK 28 BK 29 Installation Instructions 818689-00 Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME Contents Important Notes Page Usage for the intended purpose...4
More informationLevel Electrode NRG NRG Original Installation Instructions English
Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and
More informationTHERMODYNAMIC STEAM TRAP
THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,
More informationMODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS
MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS 1. FEATURES The Type N Trap range is particularly suitable for high pressure/high temperature trapping applications
More informationINSTALLATION, OPERATION
OM No. E-SCSF-170111-1 INSTALLATION, OPERATION and MAINTENANCE MANUAL Thermodynamic Steam Trap MODEL: SC/SF MIYAWAKI INC. Osaka, Japan 2 SAFETY INSTRUCTION Prior to using the SC/SF steam trap, read this
More informationSeries 1140 and 1141 Temperature Regulators
Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE
More informationInstallation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63
Installation and Maintenance Manual Forbes Marshall Tracer Line Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationGEM TRAP FITTING & MAINTENANCE INSTRUCTIONS
GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS IMPORTANT Please read these instructions before fitting any traps. The following pages describe how each type of GEM Trap should be installed. If you are unsure
More informationFT14 Ball Float Steam Trap (Screwed)
Page 1 of TI-S02-0 ST Issue 9 Cert. No. LRQ 096008 ISO 9001 FT14 Ball Float Steam Trap (Screwed) Description The FT14 is an SG iron bodied ball float steam trap having stainless steel working internals
More information13-1. Temperature Regulator
-1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details
More informationInstruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity
- Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector
More informationInverted Bucket Steam Traps
INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,
More informationS and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions
0772150/4 IM-P077-02 ST Issue 4 S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions 1. General safety information 2. General product information 3. Installation 4. Commissioning
More informationMachine needle shut-off nozzle type-s
Machine needle shut-off nozzle type-s spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More informationTemperature Sensor TRG Original Installation Instructions English
Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationArmstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual
Armstrong J Series, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual This bulletin should be used by experienced personnel as a guide to the installation
More information"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16
Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD VALVES,
More informationOPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F
OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More informationWater level controller and limiter
Water level controller and limiter RBA 25 RBA 35 D-07-B-16634-EN-0 Edition 10/09 -i Table of contents- 1. Health and safety instructions 4-5 1.1 General health and safety instructions...4 1.2 Unit-specific
More informationBK 46. Installation Instructions Steam Trap BK 46
BK 46 Installation Instructions 810645-00 Steam Trap BK 46 1 Capacity Chart 2 1 Fig. 1 1 2 Max. discharge capacity of hot condensate Max. discharge capacity of cold condensate 2 Design A B C D D E E1 F
More informationopening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)
Issue Date: 4/06 GESTRA Steam Systems Thermostatic Steam Traps MK 45-, MK 45-2 PN 40, DN 5, 20, 25 (½", ¾", ") Product Range A MK 45- MK 45-2 Description Thermostatic steam trap with membrane regulator.
More informationPump assembly Instruction manual
Instruction manual EN Version 2.0 /Release 06/2012 Table of content 1 Key background information...3 1.1 Limitation of liability...3 1.2 Responsibilities of the operator...3 1.3 Documentation...3 1.3.1
More informationInstructions for Installation, Operation, Care and Maintenance
Bulletin 422 Model E Alarm Check Valve Bulletin 422 Instructions for Installation, Operation, Care and Maintenance DN100, DN150, DN200 SIZE Model E with E2 Euro Trim The Reliable Automatic Sprinkler Co.,
More informationNRG NRG NRG NRG
GESTRA Steam Systems NRG 16-50 NRG 17-50 NRG 19-50 NRG 111-50 EN English Installation Instructions 818954-04 Level Electrodes NRG 16-50, NRG 17-50, NRG 19-50, NRG 111-50 1 Contents Important Notes Page
More information"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8
Webster Pumps "S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING Webster PUMPS or HAYWARD
More informationInstallation & Operation Instructions Nr _EN_Manual
Installation & Operation Instructions Nr. 100087_EN_Manual Product: Fog / Jet Monitor (FJM) Manual and Manual with Foam Inductor Versions Model Types: FJM-80, FJM-100, FJM-150 FJM-80S, FJM-100S, FJM-150S
More informationOwner s Manual Crimping Machine CM 25-6
Owner s Manual Crimping Machine CM 25-6 Before starting any work please read operationg instructions Rev.: 2015-04-22 1 / 14 Table of Contents 1. Preface 3 2. Technical Data 3 2.1 Setup/Construction 4
More informationOperation, Maintenance and Installation Manual
Manual No. FS-OM1-5 1-16 in. FloodSafe Inflow Preventer Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 CONSTRUCTION...
More informationInstallation manual plugs and connectors QUICK-CONNECT (63 A)
EN Installation manual plugs and connectors QUICK-CONNECT (63 A) 60003217 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal
More informationFLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)
LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam
More informationTQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.
TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih
More informationMontageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)
Montageanleitung (Original) (Translation of the original) DE MA_ 1.0 06/2014 Taperlock Clamping-bush system _0 _1 Fixed hub Inlet nozzle with IMV 1. Revision index Revision Date MA_ 1.0 06/2014 2. Safety
More informationService package PDAD- -SP (en) Assembly instructions d [ ]
Service package PDAD- -SP-12000 (en) Assembly instructions 8068819 1701d [8068821] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with
More informationMechanical seals external, single or double, to DIN EN 12756
INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly
More informationIndustrial Filters Replacement Procedure
FGD FGE FGET FGG Vessel Series Vessel Series Vessel Series Vessel Series p. 537 p. 538 p. 540 p. 543 FGA FGB FGC FGF Vessel Series Vessel Series Vessel Series Bag Filter p. 545 p. 549 p. 553 p. 555 FGH
More informationLP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions
4024750/9 IM-P402-44 AB Issue 9 LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Wiring 5
More informationGrain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation.
Grain crusher Universal. Purpose: This machine is designed for the crushing of grain in agricultural operation. Operating instructions and parts catalogue This grain crusher provides you with a machine
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationMK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A
MK 45 A Stainless Steel Design Installation Instructions 810603-00 Steam Trap MK 45 A 1 Capacity Chart 1 2 3 4 Capacity 1 2 3 4 Max. flowrate of cold condensate for MK 45 A-2. Max. flowrate of cold condensate
More informationSteam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat
s s Function Level control valves control liquid levels without the necessity of an external energy input. There are two types of level controllers including:. Chambered valves such as; bleeding & venting
More information1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationModel AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description
Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,
More informationDisc Type Steam Trap TSD-42
Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat
More informationInstallation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)
EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3
More informationVacuum Switch, Differential Pressure Adapter, Switching Amplifier
Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with
More informationTechnical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved
Worldwide Contacts www.tyco-fire.com Model TJR Resilient-Seated Gate Valves Outside Screw and Yoke General Description TYCO Model TJR Resilient-Seated Gate Valves are used in Fire Protection Systems for
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR POINT OF USE STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL PS Edition 2011 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615
More informationInstallation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50
Installation and Maintenance Manual Forbes Marshall Bucket Trap Energy Conservation Environment Process Efficiency www.forbesmarshall.com Table of Contents 1. Preface...1 2. Important Safety Notes...1
More informationAdsorption dryer PDAD. (en) Operating instructions g [ ]
Adsorption dryer PDAD (en) Operating instructions 8068814 1701g [8068816] Original instructions Installation and commissioning are to be carried out only by qualified personnel in accordance with the operating
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.
INSTRUCTION MANUAL Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan Tel: [81]-(0)79-422-1122
More informationICS Float and Thermostatic Steam Trap Installation and Operation Manual
ICS Float and Thermostatic Steam Trap Installation and Operation Manual 59 Table of Contents. General Safety Information. 3 Product Information. 4 Product Installation. 5 Service and Maintenance. 6 Troubleshooting.
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationWarranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5
5 . Manual Contents Warranty Details page 2 Pump Description & Technical page 3 Specifications Transportation, Storage & Installation page 4 Pump Maintenance page 5 Wet end Dismantling page 6 Wet end Assembly
More informationRadiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function
HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationTITAN FLOW CONTROL, INC.
PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Suction Diffusers. To ensure efficient and safe operation
More informationA AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1
A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern
More informationOperating Instructions. Rotating Vacuum Filter Type VRF
Operating Instructions Rotating Vacuum Filter Type VRF GB Rotating Vacuum Filter Type VRF Table of Contents 1 Description of machine and functions... 5 2 Danger and safety instructions... 6 2.1 General
More information1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide
1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct
More informationWaste water ejection unit
Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders...
More informationAudi-Larm Audible Alarm
Audi-Larm Audible Alarm MAINTENANCE AND REPAIR TAL 1706 (L) Rev. 7 MSA 2017 Prnt. Spec. 10000005389(I) Mat. 10093084 Doc. 10093084 REPLACEMENT KITS AND PARTS LIST TAL 1706 (L) Rev. 7-10093084 2 Exploded
More informationSTEAM TRAPS
STEAM TRAPS 08.2016 info@ayvaz.com www.ayvaz.com SELECTION OF STEAM TRAPS In order to get maximum efficiency and service life from the steam lines and steam related systems, it is crucial to make the correct
More informationVacmobile 20/2. Instruction manual OPERATION & SERVICE
This instruction manual provides general instructions for the Vacmobile 20/2 vacuum system. This machine may use either the Becker U4.20 or the PVR EM 20/B vacuum pump. Service information specific to
More informationInstallation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator
Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator 2008 Groth Corporation IOM-8331 Ref. ID: 95566 TABLE OF CONTENTS: GENERAL SAFETY INSTRUCTIONS 3 SAFETY WARNINGS 3 INSPECTION
More informationINSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer
INSTRUCTION MANUAL Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES SS3N SS3V / SS5N SS5V / SS5NH SS5VH Manufacturer 881 Nagasuna, Noguchi, Kakogawa, Hyogo
More informationFSW300 Series Flow Switch
. FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of
More informationBall Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass
Product of Quality Best Performance Ball Float Controlled Steam Traps Auto Drain Traps Float Valve Air Vent Valves Feed Control Valve Drain Control Valve Thermo Dynamic(TD) Trap Safety Valve Condensate
More informationInverted bucket steam traps Type OKZ PN6/PN16
-TERMOENERGETIKA- Inverted bucket steam traps Type OKZ PN6/PN16 We produce the inverted bucket steam traps type OKZ for nominal pressures PN 6 and PN 16 These traps have automatic air vent on the start-up.
More informationAC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY ELECTRICAL CONNECTIONS INSTALLATION
AC 4 & 5 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationInstallation manual extra-low-voltage socket outlets for panel- and surface-mounting
EN Installation manual extra-low-voltage socket outlets for panel- and 60003221 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal
More informationConductivity Electrode LRG Original Installation Instructions English
Conductivity Electrode LRG 16-4 EN English Original Installation Instructions 818854-02 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...5 Directives and standards
More informationSERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION
SERVICE MANUAL Installation, Operation and Maintenance Manual for Standrd Pre-Engineered Shell & Tube Models BCF, HCF, HFF, SSCF & SX2000 Fixed Tube Sheet Heat Exchangers For Service & Parts please call
More information569, 570, 571, 572 Series
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationPT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.
PT5 Thermodynamic Steam Traps MATERIAL : No. PART MATERIAL QTY. (Nos.). BODY ASTM A743 Gr. CA 40 0 (Seat Hardened) (Cast Equiv. AISI 420) 2. DISC CAP ASTM A743 Gr. CA 40 0 (Cast Equiv. AISI 420) 3. DISC
More informationMNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions
FARM PRODUCTS DIVISION MEMBER OF AMCA AMERICAN COOLAIR CORPORATION P.O. BOX 2300 JACKSONVILLE, FLORIDA 32203 PHONE (904) 389-3646 FAX (904) 387-3449 E-MAIL - fans@coolair.com MNEFDD54 & MNBCDD54 GALVANIZED
More informationModel T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!
Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model
More informationInstructions. Duct Mount Accessory Q Rev: 11/
Instructions Duct Mount Accessory Q5016 Rev: 11/16 95-8752 Table of Contents DESCRIPTION...1 FEATURES...1 OPERATION...1 SPECIFICATIONS.... 2 INSTALLATION... 2 Detector Location...2 Tools for Assembly...4
More informationCatalog. Self-operated Regulators Volume 2 Temperature Regulators
Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure
More informationINSTALLATION INSTRUCTIONS CARE AND MAINTENANCE
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE Heritage VorMax Right Height Elongated 2-piece Toilet Model 205AA104 Thank you for selecting American Standard - the benchmark of fine quality for over 100
More informationManual / Handbuch Spare parts list / Ersatzteilliste
Manual / Handbuch Spare parts list / Ersatzteilliste Equipment Imp.-Exp. GmbH Zitterpappelweg 9 D - 22391 Hamburg Tel.: + 49 40 60009468-0 Fax: + 49 40 536 75 01 E - M a i l : i n f o @ w e s c o - n a
More information