For details of the full range of Wholehouse Heat Recovery Systems please refer to the Vent-Axia Clean Air Systems Brochure

Size: px
Start display at page:

Download "For details of the full range of Wholehouse Heat Recovery Systems please refer to the Vent-Axia Clean Air Systems Brochure"

Transcription

1 For details of the full range of Wholehouse Heat Recovery Systems please refer to the Vent-Axia Clean Air Systems Brochure

2 Multivent Wholehouse extract ventilation Central Extract System The Multivent continuous mechanical extract ventilation range is designed for the simultaneous ventilation of separate areas in the home or as a multi-point extractor system for a wide range of commercial applications. In the home the system is usually located in the loft or airing cupboard with ducts taken to the bathroom, kitchen and utility room to remove water vapour at source and from WC s to remove odours. Designed to provide 0.7 of an air change based on the volume of the building, the Multivent system provides adequate ventilation, even in a tight dwelling. Pollutant concentrations and humidity can be controlled. Suitable for wall, loft or ceiling mounting. No cross contamination due to continuous running. Speed operation using PIR, manual switch, integral humidistat or wireless controller. Ideal for use with shower LuminAir Vent Light accessory. Can extract from a number of rooms, depending on size of dwelling. Multivent is ideal for a range of commercial multipoint extract applications such as WC s, fitting rooms, and kiosk's. The units can be installed at any angle and where the ambient air has a high humidity content condensate drains are provided. The Multivent H versions are now available with 2 control options. An integral humidity sensor that will detect any rise in humidity within the system and will boost between any 2 of the 3 speeds. A new Wire-less Controller is available for use with the Multivent H with 3 speed options offering total control of the systems. Wire-less Controller Stock Ref. No Typical domestic installation > Six models: MV250, MV250H, MV350, MV350H, LoWatt MVDC and LoWatt MVDCH models with a motor offering long life and extremely low power consumption. > Fitted with four extract 125 or 100mm diameter spigots allowing quick connection to ducts. > Fitted with a condensation drain for wet areas. > Option of wall, ceiling and loft mounting. > Quiet operation suitable for continuous operation. > Integral humidity sensor or Wire-less Controller available. LoWatt MVDC The LoWatt MVDC Multivent minimises running costs by incorporating the latest DC technology. DC efficiency means less wear and tear on the motor which guarantees longer life. Multivent MV250 and MV350 are guaranteed for 2 years with an extended motor guarantee to 5 years offered on the MVDC LoWatt model. Supply and install a Multivent wholehouse ventilation system as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Tel: The system should be able to extract from multiple areas within a property not exceeding 450m 3. The system should be mounted in a loft area or kitchen cupboard with one outlet to atmosphere. The unit should be BEAB approved. The unit should have three speeds and be capable of running at low speed with boost and incorporate an optional integral humidity sensor and Wire-less Controller facility to increase to any of the higher speeds. The unit should meet building regulations under the alternative approach Digest 398 from the British Research Establishment (BRE). The motor should be of the backward curved centrifugal type and have sealed for life ball bearings for no maintenance and any angle installation and be fitted with Standard Thermal Overload Protection (S.T.O.P.). Sound Levels Ø Ø Ø 125 Stock FID 3m Ref. No. Performance m 3 /h Casing Breakout Duct Inlet 100mmØ Duct Inlet 125mmØ MV A low medium high MV250H A low medium high MV A low medium high MV350H A low medium high MVDC B low medium high MVDCH A low medium high Technical Data Multivent Installation Packs Accessory kits for Multivent installations including flexible duct, grilles, diffusers etc. 2 point Extract kit. Stock Ref. No point Extract kit. Stock Ref. No point Extract kit. Stock Ref. No Settings Low Medium High Current Power Current Power Current Power Amps Watts Amps Watts Amps Watts MV MV250H MV MV350H MVDC MVDCH STATIC PRESSURE (Pa) STATIC PRESSURE (Pa) Performance MV 250 & 250H High medium Low Output m 3 /h MV 350 & MV350H STATIC PRESSURE (Pa) High 300 medium Low Output m 3 /h MVDC & MVDCHLoWatt Long Life Model High 300 medium Low Output m 3 /h For Wiring Diagrams see pages 230. LoWatt Multivent - continuous mechanical extract ventilation 72 73

3 Wholehouse Ventilation Accessories Wholehouse Ventilation Accessories Aircheck A15/40 Electrically operated 125mm extract grille. Constant airflow of 15m 3 /h, opening to 40m 3 /h when electrically operated. Stock Ref. No Aircheck A65/120 Electrically operated 125mm extract grille. Constant airflow of 65m 3 /h, opening to 120m 3 /h when electrically operated. Stock Ref. No Aircheck P15/40 A pullcord operated 125mm extract grille. Constant airflow of 15m 3 /h, opening to 40m 3 /h when operated. Stock Ref. No Aircheck PT15/40 A pullcord/timer operated 125mm extract grille. Constant airflow of 15m 3 /h, opening to 40m 3 /h when operated. Stock Ref. No Aircheck HPT40/70 An auto humidity/pullcord/timer operated 125mm extract grille. Constant airflow of 40m 3 /h, opening to 70m 3 /h when operated. Stock Ref. No Aircheck HPT65/120 An auto humidity/pullcord/timer operated 125mm extract grille. Constant airflow of 65m 3 /h, opening to 120m 3 /h when operated. Stock Ref. No Aircheck H40/70 An auto humidity operated 125mm extract grille. Constant airflow of 40m 3 /h, opening to 70m 3 /h when operated. Stock Ref. No Aircheck H65/120 An auto humidity operated 125mm extract grille. Constant airflow of 65m 3 /h, opening to 120m 3 /h when operated. Stock Ref. No Aircheck Induct An in duct damper with constant airflow. 100mm ID45 45m 3 /h Stock Ref. No mm ID m 3 /h Stock Ref. No mm ID15 15m 3 /h Stock Ref. No mm ID30 30m 3 /h Stock Ref. No mm ID45 45m 3 /h Stock Ref No Aircheck Corner Diffuser (CD100/125) A corner diffuser for replacement air. CD100 Stock Ref. No CD125 Stock Ref. No Aircheck Ceiling Adaptor (CA125) A 125mm ceiling adaptor for connection to ducting. CA125 Stock Ref. No Circular Supply Diffusers Manufactured from polypropylene plastic. Suitable for supplying air and can be fitted directly to the duct or in the ceiling. 100mm dia Stock Ref. No mm dia Stock Ref. No mm dia Stock Ref. No Circular Exhaust Diffusers Manufactured from polypropylene plastic. Suitable for exhausting air and can be fitted directly to the duct or in the ceiling. 100mm dia Stock Ref. No mm dia Stock Ref. No mm dia Stock Ref. No Aluminium Flexible Ducting Lightweight, easy to install ducting. The ducting is made up of 5 layer aluminium foil/polyester on a steel wire helix. Fire resistance: when assessed against the integrity criterion of BS 476 Part , the ducting is capable of providing in excess of 30 minutes integrity from inside to outside. Classified as Class I to BS 476 : Part 7 : Standard length: 10 metres. 100Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No NB. For maximum fan performance it is important that flexible ductwork is fully extended, and is adequately supported to eliminate unnecessary bends. Intended bends should be of largest possible radius. 100 Dia Tube length 100 Stock Ref. No Quick Fix Termination Designed to be installed from inside the building to a nominal 115mm diameter core-cut hole, saving time and cost. Stock Ref. No A Insulated Flexible Duct (10m) Insulated duct to limit condensation forming in duct when extracting from wet areas. Minimised heat loss when used with Heat Recovery fans. 100mm diameter Stock Ref. No mm diameter Stock Ref. No mm diameter Stock Ref. No Wall Fitting Kit Telescopic liner and external grille to fit wall thicknesses from mm. 100 Ø Stock Ref. No White 100 Ø Stock Ref. No Brown 150 Ø Stock Ref. No A White 150 Ø Stock Ref. No A Brown A range of small section rectangular ducting and fittings, particularly suited to the low air volumes and velocities associated with wholehouse heat recovery ventilation systems. The plastic components are moulded in white from self-extinguishing materials to meet DIN The nominal dimensions of the duct are 110 x 54mm. Flat Channel length 1m Stock Ref. No length 1.5m Stock Ref. No Flat Channel End Cap Stock Ref. No Flat Channel Connector Stock Ref. No Flat Channel Connector with Damper Stock Ref. No Elbow Bend with Socket - 100mm I/D Stock Ref. No Elbow Bend with Spigot - 100mm O/D Stock Ref. No Horizontal 90 Bend Stock Ref. No Vertical 90 Bend Stock Ref. No Round to Rectangular Adaptor - 100mm I/D Stock Ref. No Short Round to Rectangular adaptor Stock Ref. No Horizontal T-Piece Stock Ref. No Louvred Grille with Flyscreen - round fitting - 100mm O/D Stock Ref. No Louvred Grille with Flyscreen - rectangular fitting Stock Ref. No Round Louvred Grille Stock Ref. No Flat Channel Wall Plate Stock Ref. No Flat Channel Clip Stock Ref. No Airbrick Adaptor Stock Ref. No Horizontal Louvred Airbrick Stock Ref No (White) Stock Ref No (Brown) Stock Ref No (Beige) Stock Ref No (Terracotta) Extra Circular Fittings for Specific Ducted Applications Equal Tee 100 Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No Bend 100 Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No Female Coupler 100 Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No Balancing Damper 100 Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No Flanged Spigot 100 Ø Stock Ref. No Concentric Reducer 100/125 Ø Stock Ref. No /150 Ø Stock Ref. No /150 Ø Stock Ref. No Intumescent Fire Dampers 100 Ø Stock Ref. No Ø Stock Ref. No Resettable Fire Dampers 100 Ø Stock Ref. No Ø Stock Ref. No Ø Stock Ref. No Diffuser with Integral Fire Damper 100 Ø Stock Ref. No Ø Stock Ref. No Filters 130 x 130 x 6mm. Fire retardant reticulated foam filter Stock Ref. No Wholehouse Ventilation and Heat Recovery Accessories 74 75

4 PoziDry Positive pressure wholehouse ventilation system Positive Pressure Ventilation For controlling condensation particularly in the refurbishment sector, the Vent-Axia pozidry offers a quick and simple solution. A loft mounted positive input fan draws fresh air from atmosphere, filters it and pushes into the dwelling via a ceiling mounted diffuser. All stale air in the property is forced out through the natural forms of ventilation, such as window mounted trickle vents. This entire design is a result of close consultation with the public sector authorities. This valuable feedback has resulted in special attention to key design features such as robust construction, longer life filters, user friendly operation, reliable controls and wiring flexibility. Installation It is simply installed, out of sight in the loft space, with a purpose-designed diffuser normally located over the stairwell of a conventional two story dwelling or in the main hall of a bungalow. PoziDry is set to the appropriate speed at installation based on the 14 dba using 8W of power on trickle vent. size of the dwelling, providing positive pressure input ventilation. Background ventilation openings provide the exhaust points. Performance The robust construction of the PoziDry features two larger than normal high capacity, extra long life filters to EU3 combined with upward deflecting protective grilles to ensure maximum efficiency and filter life. A specially developed LoWatt DC fan/motor arrangement quietly delivers incredibly low running costs. The special insulation mounts provided ensure PoziDry is user friendly and quiet in operation. Auto Speed Control Vent-Axia s built-in new generation electronics module monitors temperature to control condensation and minimise running costs. > Selectable air capacities to suit house volumes of up to 400m 3, or floor area up to 150m 2. > Uses latest LoWatt technology motor for low running costs. > Ultra Low sound level. > PoziDry comes complete with ceiling diffuser, flexible duct worm drive clips and anti-vibration mounts. > Standard 5 year guarantee. Bathroom Humidity Control There is also a facility to connect an external sensor or switch to select maximum airflow for special requirements. Stock Ref. No Fresh incoming Air Warm incoming Air Tempered Air Stale Air Supply and install a Pozidry positive pressure loft unit for wholehouse condensation control as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX. Telephone: The unit should be mounted in the loft space on anti-vibration mounts and ducted to a two part outlet diffuser in self-extinguishing ABS positioned at the top of the stairwell. The unit should meet all EMC and low voltage directives and be BEAB Approved. The unit should have 3 speed settings: low, medium and high, and incorporate an extra low speed setting, which automatically cuts in when the temperature drops below 5 C. A tamper-proof cover to prevent casual interference in the running of the unit should cover the switch. The unit should have an optional dry out feature which will continuously run the unit for a 14 day period and then revert to the selected setting. The motor should be of the Lowatt DC type with long-life ball bearings suitable for ambient operating temperatures of -25 C to +40 C and should be fitted with Standard Thermal Overload Protection (S.T.O.P.). Motor The electronically controlled motor is manufactured with long life ball bearings and is fitted with Standard Thermal Overload Protection (S.T.O.P.). Suitable for ambient operating temperatures of -25 C to +40 C. Static Pressure (Pa) Performance Sensor Volume (m 3 /h) Vent-Axia HumidiSwitch An adjustable mechanical humidity sensor incorporating electrical contacts for On/Off or trickle to boost switching in response to a rise in humidity. Adjustable from 20% to 80% RH. Stock Ref. No D An optional time elapse meter is available upon request. Roomside Ceiling Grille D A B C D E Ø198 Max. 450 Weight 11.5 kg A B C D C B A LoWatt Pozidry - positive pressure wholehouse ventilation system Can be used for air replacement in conjunction with an extract fan. Can be switched to boost speed by remote HumidiSwitch. EU3 filters as standard. Installation and surveys are available on this product. Unique Dry out feature For newly constructed buildings that are still drying out, a selectable built-in link allows Pozidry to run at maximum speed for an initial 14 days to help dry out the building, after which it automatically reverts to the installed settings. Typical installation Cut-away illustration of PoziDry fan unit mounted in loft area For complete peace of mind the Vent-Axia PoziDry is backed by a 5 year guarantee upon registration. Pozidry internal grille Speed rpm Watts m 3 /h 3m High Medium Low Ex. Low N/A 76 77

5 PoziDry Compact Positive pressure input ventilation system Positive Pressure Ventilation For those properties that do not have a loft, LoWatt PoziDry Compact provides an easy to install solution. The duct mounted unit that can be fitted in a number of locations around a single floor flat or apartment. Air is drawn into the PoziDry Compact unit via an external inlet* and through a short length of duct*. The specially developed fan/motor assembly (using the LoWatt DC motor technology) draws the air through an integral, high capacity, washable filter. The forward curved impeller guarantees increased efficiency, lower sound levels and better performance. The fresh, filtered airflow passes along the ducting and terminates on an internal wall with a discreet grille*. This directs the airflow upwards where the incoming air mixes with the warm air that gathers at ceiling height. 14 db(a) using 6W of power at trickle speed. Can be used for air replacement in conjunction with an extract fan. Can be switched to boost speed by remote HumidiSwitch. EU3 filter as standard. Installation and surveys are available on this product. The system automatically provides fresh, tempered airflow into the home. There is minimal power consumption and costs as little as one penny a day to run. Creating an environment where the damaging effects of condensation find it hard to exist, benefits both the occupants and the structure of the home. Unique dry out feature For newly-constructed buildings that are still drying out, a selectable built-in link on PoziDry Compact allows the unit to run at full speed for > Ultra low sound level. > Selectable air capacities to suit volumes of up to 250m3 or Floor area up to 100m2. > Extremely low running costs - from less than one penny per day. > Washable, high capacity filter. > Round to rectangular duct adaptor included. > 14 day link for high speed drying out of new, refurbished or unoccupied flats. > 5 Year Guarantee. an initial 14 days. This helps to dry out the building. The unit then automatically resets to the installed settings. There is also a facility to connect an external humidity sensor to select maximum airflow for rooms with special requirements, such as heavily used bathrooms and kitchens. Stock Ref. No: *Vent-Axia ventilation accessories. Supply and install a PoziDry Compact positive pressure flat unit for condensation control as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: The unit should be mounted on the wall with a inlet from atmosphere and on the supply side flat duct to the central area of the property. The unit should meet all EMC and low voltage directives and be BEAB Approved. The unit should have 3 speed settings: low, medium and high, and incorporate an extra low speed setting, which automatically cuts in when the temperature drops below 5 C. A tamper proof cover to prevent casual interference in the running of the unit. The unit should have an optional dry out feature which will continuously run the unit for a 14 day period and then revert to the selected setting. The motor should be of the Lowatt DC type with long life ball bearings suitable for ambient operating temperatures of -25 C to +40 C and should be fitted with Standard Thermal Overload Protection (.S.T.O.P.). Installation Packs A B C Sensor HumidiSwitch An adjustable mechanical humidity sensor incorporating electrical contacts for On/Off or trickle to boost switching in response to a rise in humidity. Adjustable from 20% to 80% RH. Stock Ref. No D An optional time elapse meter is available upon request. Accessories Wall Fitting Kit This telescopic kit will fit most walls when used as an air intake wall liner for Pozidry Compact installations. Stock Ref. No White Brown Quick Fix100mm Wall Grille Terminates a rigid duct on an outside wall using the quick fix side grips without the need of further fixings. Stock Ref. No White Brown Quick Fix 100mm Termination The Quick Fix wall termination is designed to be installed from inside the building to a nominal 100mm diameter core-cut hole, saving time and cost. Four sealing rings afford a watertight fit to the wall external leaf. Stock Ref. No B D A B C D E F G Ø Weight: 7 kg G A C E B Rear duct entry option Duct Adaptor (included) A ØB C x 110 The PoziDry Compact unit is easily installed discreetly above a cupboard in a kitchen. Stock Ref No Air Replacement Grille Set B Quick Fit Grille, For air replacement through doors. Consists of C 100mm Wall Circular Rectangular White Rectangular flat a two-piece telescopic set, which fits fitting kit ducting flat duct Wall fitting kit, duct wall plate Internal Brown unobtrusively on either side of the door panel. A outlet grille HR 70WH Rdn- Minimum fixing thickness 30mm. Plastic. Rect Ad Dimensions: 454 x 90mm. AIRFLOW HR 060WH Vert Stock Ref. No Ivory For duct and fitting, please refer to page bend Brown Ind 040WH Elbow/Spgt HR 010WH 1m Flat Chnl HR 015WH 1.5m Flat Chnl HR 020WH Speed m 3 /h 3m Watts Connector High HR 050WH Horiz Medium Bend Low HR 122-H Chnl Clip Ex. Low 45 N/A 3 External PoziDry Circular to Rectangular wall grille Compact rectangular flat duct clip duct connector F LoWatt Pozidry compact - positive pressure Input Ventilation System 78 79

6 HR25 Through wall mounting heat recovery unit > Designed for installations in Bathrooms, Toilets, Utility Areas. > 84% temperature based heat recovery. > Controls condensation and eliminates mould. > Choice of control options. E E Supply and install a HR25 Heat Recovery Unit, through the wall mounted unit for use in bathrooms and WC s as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using an ABS UV stable tube duct with black EPDM rubber wall seals and complete with rear grille. mm A B C D E F Standard long A B C D Long Life Ventilation The Vent-Axia HR25 range of through the wall heat recovery units are suitable for fitting through a 152mm (6 ) circular hole and are designed for use in bathrooms. Available in 2 lengths, a standard version suitable for wall thicknesses of up to 310mm and an extended version suitable for wall thicknesses of up to 425mm. The Vent-Axia HR25 is available in 3 models, a standard version with pullcord control, a H version with an integral humidity sensor and a P version with integral PIR detector. Performance The units are fitted with a 24V DC motor and are supplied with a state of the art Switch Mode Power Supply (S.M.P.S.) This has the ability to operate at only 2 Watts power consumption on normal setting. A 5m cable is provided for fixed wiring of the unit to the S.M.P.S. Suitable for wall mounting only, not suitable for ceiling mounting. Meets building regulations for bathrooms and toilets. Easily installed using 152mm (6 ) core drill. Typical Installation The HR25P unit is designed for installation in a 152mm (6") core drilled hole. All installation can be carried out from inside the building. The standard units are suitable for external walls up to 310mm thick. For thicker walls extended models are available, suitable for walls up to 425mm thick. Maintenance Apart from removing odours, providing fresh air and recovering heat, this appliance extracts airborne impurities such as dust, dirt and grease. These gradually build up and detract from the efficiency and appearance of the appliance. Therefore to ensure peak performance, the appliance should be cleaned regularly. Filters should be replaced every six months or as conditions necessitate. The heat exchanger and grille should be washed in warm soapy water every twelve months or as conditions necessitate. Models HR25 The HR25 is fitted with a pull cord switch which operates the twin speed control function. Stock Ref No HR25H The HR25H is fitted with an adjustable humidity sensor which automatically switches between its high and low settings depending on the relative humidity in the room. Stock Ref No HR25P The HR25P has an Infra-red sensor which detects a person moving in the room, this then activates the unit to switch to its higher setting. This unit can operate under two different modes, direct action and delayed action. Stock Ref No HR25L An extended version of the HR25 is available, designed for installations where the wall thickness is between 311mm and 425mm. Stock Ref No HR25LH An extended version of the HR25H is available, designed for installations where the wall thickness is between 311mm and 425mm. Stock Ref No HR25LP An extended version of the HR25P is available, designed for installations where the wall thickness is between 311mm and 425mm. Stock Ref No The internal grille should incorporate a reticulated foam type coarse filter to remove airborne pollutants from both exhaust and supply airstreams. The heat exchanger should be made of polymer UPVC and retain up to 84% of the temperature differential of the outgoing air. The motor should be a 24 volt DC motor with Switch Mode Power Supply (S.M.P.S.) and power consumption to be 2 W (Low) and 23W (High). Installation should only require a 152mm core drill. Grille Insert Filter Contol Board Enclosure Top Profile Side Profile Heat Exchanger Divider Board Rubber Wall Seals Extract Intake Grille Stock Weight Performance m 3 /h Performance m 3 /h Watts 3m * Type Colour Ref. No. kg Boost Trickle Boost Trickle Boost Trickle Boost Low HR25 White HR25H White HR25P White HR25L White HR25LH White HR25LP White * Active band frequency range of 250Hz to 4KHz at 3m. Unit mounted on a reflective surface. F HR25 - Through wall mounting heat recovery ventilator 80 81

7 HR100S Single room heat recovery unit > Single room domestic heat recovery ventilation unit. > Saves energy - controls condensation. > Up to 60% heat recovery. > Extremely quiet trickle ventilation mode. > Easy to install. > Rated to IP44. Supply and install a HR100S Heat Recovery Unit, a surface mounted unit for condensation control in bath and shower rooms as manufactured by Vent-Axia ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using a split tube duct and brown external grille provided. The internal casing should incorporate the supply grille covering a washable reticulated foam filter. The heat exchanger should be made of polymeric plastic and should retain up to 60% of the temperature differential of the outgoing air. Sensors Ambient Response Humidity Sensor A new electronic On/Off wall mounted humidistat, which reacts to any rapid increase in both humidity and temperature, switching a Vent-Axia fan On for rapid removal of moisture laden air. Night time RH increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls. Pullcord trickle/boost override and neon indicator for use with HR100S. Stock Ref. No A B C D E mm F G H J K mm Low Energy Ventilation The Vent-Axia HR100S heat recovery ventilation unit is surface mounted with a 100mm diameter intake/extract duct through the wall to an external louvre grille. The motor is dual speed, offering a low speed 'trickle ventilation' rate of 30m 3 /h, and a high speed boost ventilation rate of 75m 3 /h extract. Ideal for condensation control of bath and shower rooms, whilst saving the majority of the heat. Heat Exchanger The model comes complete with a highly efficient, polymeric heat exchanger cube. The compact washable cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 60% of the heat that could otherwise be lost is transferred to the incoming air,optimizing energy savings. Energy is saved on room heating with no power being used by the cube itself. Mains voltage units and associated controls must be out of reach of a person using a bath or shower. Easy Installation The HR100S model requires a nominal 115mm diameter hole through the wall. The wall tube provided incorporates a vertical web to separate the extract from the intake air flow. An external louvre grille is supplied. The unit has a washable acrylic fibre filter. An Extension Sleeve is available Stock Ref. No Model HR100S Two speed, surface mounted, extract and intake heat recovery ventilation unit for bathrooms and WC's V/1/50Hz. Class 1 earthed appliance. Stock Ref. No INTAKE (Cool fresh The motor should be a dual speed shaded pole induction type and fitted with Standard Thermal Overload Protection (S.T.O.P.). Vent-Axia HumidiSwitch An adjustable mechanical humidity sensor incorporating electrical contacts for On/Off or trickle to boost switching of heat recovery ventilation units in response to a rise in humidity. Adjustable from 20% to 80% RH. Suitable for use with HR100S. Stock Ref. No D Nominal hole through the wall 115 mm HR100S - single room heat recovery unit Higher extract rate to ensure negative room pressure. EXTRACT (warm stale Exhaust (Cool stale Suitable for bathrooms and WC s. Constant trickle speed or boost using a humidistat. 400mm extended wall sleeve available as an accessory. SUPPLY (Warmed fresh Extract Intake Ambient Stock Weight Performance m 3 /h Performance m 3 /h Watts 3m Response Type Colour Ref. No. kg Boost Trickle Boost Trickle Boost Trickle Boost Trickle Humidity Sensor HR100S White

8 Long Life Ventilation The Vent-Axia HR100W range is designed for continuous operation providing up to 70% Heat Recovery. Effectively controlling internal relative humidity. The Vent-Axia HR100WH unit come complete with integral humidity sensor and controls condensation and reduces mould. HR100W Remote Mounting Heat Recovery Unit Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air. An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply, raising the temperature of the fresh air and most importantly reducing the Relative Humidity of the supply air to the room. The HR100W has a two speed motor which provides for constant low rate ventilation automatically switching to boost speed at the factory-set humidity level of approximately 70% relative humidity at 20 C. This level can easily be adjusted by removing the front cover and heat exchanger to reveal the adjustment spindle. Constant trickle speed or boost using a humidistat. 500mm extended wall sleeve available as an accessory. Suitable for through the wall applications only, not suitable for ceiling mounting. Installation HR100W units require a 240mm x 160mm hole. The unit should be fitted so that it slopes towards the outside (nominal 1 degree) to assist in-built condensate drainage. The telescopic flange (adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface. An extension sleeve is available for thicker walls up to 500mm (Stock Ref. No ). EXTRACT (warm stale SUPPLY (warmed fresh INTAKE (cool fresh EXHAUST (cool stale > Designed for installation in Bathrooms/WC s. > Meets buildings regulations for bathrooms and WC s. > Eliminates Mould. > Controls Condensation. > 70% Heat Recovery. Maintenance Filters should be replaced every six months or as conditions necessitate. Replacement filters can be purchased in packs of four. (Stock Ref. No ).The heat exchanger should be washed in warm soapy water every twelve months or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille. Models HR100W Provides balanced ventilation with heat recovery and is suitable for installation in bathrooms and WC s. Stock Ref No HR100WH - With built-in Humidity Sensor A surface mounted heat recovery ventilation unit for use in bathrooms and toilets, meeting building regulations for this application. Stock Ref. No Supply and install a HR100W Heat Recovery Unit, through the wall mounted unit for use in bathrooms and WC s as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using a powder coated metal case with adjustable collar and plastic UV stabilised external cowl. The white internal grille should have a reticulated foam type filter fitted behind to remove airborne pollutants from both exhaust and supply airstreams. The heat exchanger should be made of polymer UPVC and retain up to 70% of the temperature differential of the outgoing air. The motor should be a two-speed motor safeguarded by Thermal Overload Protection, power consumption to be 12 W (Low) and 31W (High). The fans to be twin polymer alloy centrifugal impellers. To be used outside of Zone 2. Cable Entry on LHS Front Grille Filter Heat Exchanger Controllers Speed Control Switch - VCON100 White plastic single gang switch for On/Off control and Normal/Boost speed control. Stock Ref. No Trickle/Boost Switch A single gang switch to boost speeds of all heat recovery units. Stock Ref. No Accessories Extension Sleeve - EXT100 For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille. Stock Ref. No Replacement Filter Pack- HR100RF4 A pack of four replacement filters for internal grille application. Stock Ref. No Adjustable Collar External Cowl E Inside Relative Humidy % at 20 o C A B C D E F G F Humidity Removal Outside Air 0 o C 40% RH NORMAL SPEED BOOST SPEED G Moisture Removal (litres/24hr) Inner Grille Extract Intake Grille Stock Weight Performance m 3 /h Performance m 3 /h Watts 3m Type Colour Ref. No. kg High Low High Low High Low High Low HR100W White HR100WH White HR100W - Remote mounting heat recovery unit 84 85

9 Single room heat recovery unit Low Energy Ventilation > Single room domestic heat recovery ventilation unit. > 3 speed motor. > Integral washable filter. > Up to 75% heat recovery. > Saves energy - controls condensation. > Extremely quiet on low speed. The Vent-Axia HR200WK is a heat recovery ventilation unit specifically designed for use in domestic kitchens and utility rooms to meet the Building Regulations. The unit is also suitable for light commercial requirements up to 220m 3 /h. The compact, self contained unit is designed for through wall mounting. HR200WK The three speed, external rotor motor has two matched impellers to ensure a balanced air flow through the unit, with exceptionally economical 25 watt low speed power consumption. The efficient, polymeric heat exchanger cube will recover up to 75% of the heat from the extracted air, which would otherwise be lost, and transfers this to the intake air. This reduces heating bills whilst maintaining extraction of cooking odours and steam without cross contamination of the airflows. Quick release grilles give instant access to the integral washable filters. The extract rate is higher than the input to ensure negative room pressure. Suitable for kitchens and utility rooms. An additional 270mm extended wall sleeve is available as an accessory. Constant trickle ventilation, boosted by a humidistat or a 3 speed controller. Does not affect the performance of a cooker hood. Easy Installation The HR200WK fits through walls up to 335mm thick requiring a fixing hole 250mm square. The internal grille has washable, polymeric foam supply and extract filters. Only the neat internal twin grille visible from the room. A wall extension sleeve is available Stock Ref. No Heat Exchanger The highly efficient, polymeric heat exchanger cube is washable. The compact cube interleaves outgoing moist warm air with incoming fresh air and allows the heat from one to warm the other without the two air streams mixing. Up to 75% of the heat, which would otherwise be lost, is transferred to the intake air, ensuring energy saving balanced ventilation. The incoming air is tempered when it passes over the heat exchanger providing the room with drier air, therefore the humidity level drops due to the constant air movement preventing the air inside the room from becoming SUPPLY saturated with moisture. (Warmed fresh Energy is saved on room heating with no power being used by the cube itself. Electrical HR200WK V/1/50Hz Class 1 earthed appliance. The 3 speed motor, can be wired to operate On/Off for any one of the three speeds. Alternatively, an Ambient Response Humidity Sensor or simple changeover switch can be used to provide switching between any two speeds, giving permanent trickle ventilation and automatic changeover to a higher speed during periods of high moisture generation. Also the 3 speed controller enables the unit to be switched from permanent trickle to either medium or boost speed. Stock Ref. No Exhaust (Cool stale INTAKE (Cool fresh Supply and install a HR200WK Heat Recovery Unit, through the wall mounted unit for kitchen and utility rooms as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using a wall liner and should fit most standard wall thicknesses between 200 and 335mm and should be extendible up to 425mm. The unit should be BEAB Approved. The heat exchanger should be made of polymeric plastic and should retain up to 70% of the temperature differential of the outgoing air. The motor should be a dual speed shaded pole induction type and fitted with Standard Thermal Overload Protection (S.T.O.P.). Sensors Ambient Response Humidity Sensor A new electronic On/Off wall mounted humidity sensor, which reacts to any rapid increase in both humidity and temperature by switching a Vent-Axia fan On for rapid removal of moisture laden air. Night time RH increment setback feature suppresses nuisance tripping when the humidity level gradually rises as the temperature falls. Pullcord override and neon indicator. Stock Ref. No HumidiSwitch An adjustable mechanical humidity sensor incorporating electrical contacts for On/Off or trickle to boost switching of heat recovery ventilation units in response to a rise in humidity. Adjustable from 20% to 80% RH. Supply Voltage: V/1/50Hz Stock Ref. No D Controllers 3 Speed Controller A three position rotary control which enables the unit to be manually switched from permanent trickle ventilation to either medium or boost speed. Stock Ref. No Electronic 1.5A Controller On/Off neon indicator. Infinitely variable speed control. Adjustable minimum speed setting and optional sensor mode. The controller is radiosuppressed to BS800 and rated at 1.5 amps. Not to be used in conjunction with timer models. Stock Ref. No. W Accessories Extension Sleeve Galvanised mild steel extension sleeve for use with HR200WK on walls between 335mm to 550mm thick. Stock Ref. No A B C D E F mm min 335max Weight 9.7kg Wall fixing hole 250mm x 250mm sq. m 3 /h % db(a) Extract Intake Watts Heat 3m Speed Speed Speed HR200WK - single room heat recovery unit 86 EXTRACT (warm stale 87

10 Self contained through the wall heat recovery unit Long Life Ventilation The Vent-Axia HR30W provides balanced ventilation with heat recovery and is designed for installation in bedrooms giving virtually silent overnight operation with a daytime boost option. Performance The Vent-Axia HR30W unit is designed for continuous operation providing up to 70% heat recovery, effectively controlling internal relative humidity. The integral high efficiency pollen filter helps eradicate house dust mites to improve health and indoor air quality. Fresh pre-warmed air from the outside is continuously provided to the room with simultaneous extraction of stale, moist air. HR30W Higher extract rate to ensure negative room pressure. Constant trickle speed or boost using a humidistat or trickle/boost switch. 500mm extended wall sleeve available as an accessory. Suitable for through the wall applications only, not suitable for ceiling mounting. Virtually silent overnight operation on low speed. An integral heat exchanger transfers heat from the outgoing stale air to the fresh air supply raising the temperature of the fresh air and most importantly reducing the relative humidity of the supply air. This provides control of condensation and odours and creates conditions which can eliminate house dust mites. Relative Humidity Reduction The diagram demonstrates the efficiency of the Vent-Axia HR30 unit at reducing the relative humidity of the warmed fresh air supply in two common conditions for rooms being ventilated in typical British climatic conditions. Moisture Removal. The Vent-Axia HR30W unit provides an effective means of controlling condensation. The graph opposite shows the continuous moisture removal capabilities. Installation Vent-Axia HR30W units require a 240mm x 160mm hole. Units should be fitted so that they slope towards the outside (nominal 1 degree) to assist in-built condensate drainage. > Designed for installation in Bedrooms. > Pollen Filter on Fresh Air Supply. > 70% Heat Recovery. > Helps to Eliminate House Dust Mites. > Controls Condensation. The telescopic flange ( adjustable to fit walls 220mm to 280mm thick) covers cutting marks and provides a surface for forming a seal with the external wall surface. An extension sleeve is available for thicker walls up to 500mm (Stock Ref. No ). EXTRACT (warm stale SUPPLY (warmed fresh Maintenance INTAKE (cool fresh EXHAUST (cool stale Filters should be replaced every six months or as conditions necessitate. Replacement filters can be purchased in packs of four. (Stock Ref. No ). The heat exchanger should be washed in warm soapy water every twelve months or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille. Supply and install a HR30W Heat Recovery Unit, through the wall mounted unit for use to help eliminate house dust mites and provide condensation control in bedrooms where virtually silent running is required, with a daytime boost option as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using a powder coated metal case with adjustable collar and plastic UV stabilised external cowl. The white internal grille should have a reticulated foam type filter fitted behind on the extract airflow and pollen air filter on the fresh air supply. The heat exchanger should be made of polymer UPVC and retain up to 70% of the temperature differential of the outgoing air. The motor should be a two-speed motor safeguarded by Thermal Overload Protection, power consumption to be 10 W (Low) and 23W (High). The fans to be twin polymer alloy centrifugal impellers. Cable Entry on LHS Front Grille Pollen Filter Heat Exchanger Controllers Trickle/Boost Switch A single gang switch to boost speeds of all heat recovery units. Stock Ref. No Accessories Extension Sleeve - EXT100 For installation in walls from 280mm to 500mm thick. Supplied with white ABS plastic external grille. Stock Ref. No Replacement Filter pack - HR30RF4 A pack of four replacement filters for internal grille application. Stock Ref. No Adjustable Collar External Cowl Inside Relative Humidy % at 20 o C Humidity Removal Outside Air 0 o C 40% RH NORMAL SPEED BOOST SPEED Moisture Removal (litres/24hr) Extract Intake Stock Weight Performance m 3 /h Performance m 3 /h Watts db(a) Type Colour Ref. No. kg High Low High Low High 3m HR30W White E A B C D E F G F G Inner Grille HR30W - self contained through the wall heat recovery unit 88 89

11 HR300 Through Wall Mounting Heat Recovery Unit > Designed for continuous operation, providing up to 70% heat recovery. > Controls condensation and eliminates mould. > Speed controllable. > Quiet operation. > Washable filters Supply and install a HR300 Heat Recovery Unit, through the wall mounted unit for use in light commercial applications to control condensation and eliminating mould growth as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be mounted in an external wall using a cream coloured ABS plastic case with plastic internal and external grilles. Controllers Speed Control Switch - VCON6 Provides Off/Low/Normal and Boost speeds with the option of a sensor switch eg. PIR detector. Suitable for surface mounting only. Stock Ref. No A B C mm A Long Life Ventilation The HR300 provides balanced ventilation with heat recovery. It is ideal for light commercial applications including function rooms, swimming pools, offices, classrooms etc. The HR300 unit comes complete with an integral shutter device. Performance The HR300 unit is designed for continuous operation providing up to 70% heat recovery. Effectively lowering internal relative humidity the HR300 unit controls condensation and eliminates mould. Fresh, pre-warmed air from outside is continually provided to the room with simultaneous extraction of stale moist air and smells. Heat is transferred via a unique plastic heat exchanger from outgoing air to the fresh air supply with no cross contamination, maintaining internal temperatures and providing a fresh environment. The unit is fully controllable for speed using a small dedicated speed controller. Automatic ON/OFF control or switching to boost is easily achieved using sensors/timers e.g. humidistat. For summer operation the heat exchanger can be removed and replaced with a plastic divider board to provide positive cooling to rooms. Installation The HR300 unit requires a 380mm x 280mm hole. Units should be level and square in the wall. The unit should be fitted so that it overhangs by minimum of 50mm on the inside, and a minimum of 70mm on the outside. An extension sleeve is available for walls up to 650mm thick. Maintenance Filters should be cleaned by washing every six months or as conditions necessitate. Replacement filters can be purchased in packs of two (Stock Ref. No ). The heat exchanger should be washed in warm soapy water every twelve months, or as conditions necessitate. Access to the filter and heat exchanger is via two screws on the internal grille. INTAKE (Cool fresh The white internal grille should have a reticulated foam type filter fitted behind to remove airborne pollutants from both exhaust and supply airstreams. The heat exchanger should be made of polymer UPVC and retain up to 70% of the temperature differential of the outgoing air. This to be removable in summer to provide positive cooling to rooms. The two motors to be internal rotor motors fully controllable for speed and automatic On/Off control or switching to boost using sensors/timers e.g. humidistat. The fans to be twin mixed flow type impellers. Variable Speed Control - VCON5 Provides On/Off and fully variable speed control. Stock Ref. No Ecotronic Humidity Sensor An electronic On/Off humidity sensor with concealed humidity adjustment 65-90% RH with pullcord override. Neon indicator. Changeover relay switch. Stock Ref. No Accessories Replacement Filter Pack - HR300RF2 A pack of two replacement foam filters for internal grille applications. Stock Ref. No Extension Sleeve - EXT300 Galvanised mild steel extension sleeve for use on walls 430mm to 650mm thick. This unit comes complete with a divider board. For use with the HR300W6 unit only. Stock Ref. No B A C HR300 - through wall mounting heat recovery unit Designed for installation in offices, classrooms and swimming pools areas. EXHAUST (Cool stale Controls condensation and odours. 70% Heat recovery. Quiet operation. Eliminates mould growth. EXTRACT (Warm stale Extract Intake Stock Weight Performance m 3 /h Performance m 3 /h Watts 3m HR300 Ref. No. kg Low Normal Boost Low Normal Boost Low Normal Boost Heat Recovery SUPPLY (Warmed fresh 90 91

12 HR500 Commercial heat recovery unit Energy Saving Ventilation HR500 heat recovery ventilation units for through wall installation, which exhaust stale air whilst introducing warmed fresh air from the outside. Ideal for swimming pools, computer rooms, classrooms, offices and the health and leisure industries. The Vent-Axia HR500 unit is the perfect solution to commercial areas that require a high performance balanced intake/extract scheme. As a heat recovery ventilation unit it moves a useful 550m 3 /h of air. The compact heat recovery cube interleaves outgoing warm air with incoming fresh air and allows the heat from one to warm the other without the two streams mixing. Energy is saved on room heating with no power being used by the cube itself. The HR500 and HR500X consist of a tough telescopic wall sleeve into which the main body of the unit is housed. Walls of up to 670mm thick can be easily accommodated. Behind the neat deflecting fascia grilles are the filters, the heat exchange cube and fan units. All wall sleeve components, the heat exchange cube and the fascia grilles are made of tough polymeric materials. Electrical Maximum ambient temperature +40 C. > Efficient 550m 3 /h heat recovery ventilation unit or high performance 900m 3 /h extract fan. > Lightweight, compact and easy to install. > Integral Shutters on X type model. > Easy to clean. > Up to 70% heat recovery. > Controller with sensor mode, allows a range of sensors to be used in conjunction with the HR500 and HR500X units. > Rated to IPX5 suitable for swimming pool applications. Models HR500 - In Winter, the HR500 ventilates and maintains room warmth by saving valuable heat. Add an HR500 unit controller to the system and the user has greater flexibility to cope with changing needs: A choice of balanced intake/extract, or high extract, or low extract only performance. A choice of fan speeds. On, Off or sensor mode. The facility to set a minimum speed for individual rooms. Stock Ref. No B HR500X - As HR500 but with backdraught shutters in external grille operated by thermo actuators. Stock Ref. No Supply and install a HR500 Heat Recovery Unit, through the wall mounted unit suitable for swimming pools, computer rooms, offices and the leisure industries, as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX, Telephone: The unit should be ducted to atmosphere using an integral wall liner and should fit wall thicknesses between 450 and 670mm and should have washable reticulated foam filters provided in the supply and extract airflows. The heat exchanger should be made of polymeric materials and should retain up to 70% of the temperature differential of the outgoing air. The motor should be a external rotor type totally enclosed with sealed for life ball bearings requiring no maintenance and fitted with Standard Thermal Overload protection (S.T.O.P.). HR500 Controller A surface mounted controller with knockouts for recessed wiring or surface wiring. An optional flush fitting box is also available. Requires 5- core cable. One controller will operate a maximum of 2 HR500 or HR500X units. On/Off/Sensor mode. Choice of heat exchange or high/low speed extract fan mode. Infinitely variable speed control from low to high. Adjustable minimum speed. With integral thermal cut-out and circuit fuse protection. Stock Ref. No. W Flush Box Stock Ref. No Core Cable Stock Ref. No Sensors Vent-Axia HumidiSwitch. Used with the HR500 unit controller in swimming pools and other condensation prone areas. Stock Ref. No D Air Quality Sensor. Electronically senses tobacco smoke, smells etc, to switch On HR500 unit. Includes an interface relay for use with HR500 controller on sensor mode. Stock Ref. No B Vent-Axia Guardian. An infra red detector which will switch the unit On only when an area is occupied thus saving further energy costs. Stock Ref. No For full details of sensors see page HR500 and HR500X Hole opening 615 x 385mm Weight HR kg HR500X - 19 kg Inner Grille HR500 - commercial heat recovery unit In noise sensitive areas use an auto transformer controller. Higher extract rate to create negative pressure. Designed to fit walls from 450mm - 670mm. Install unit at 3 angle towards the outside for condensation drainage. Recommended for commercial use. Sound Power Level Spectra db (re Watts) Frequency (Hz) k 2k 4k 8k Heat Recovery Mode Extract Only Mode (Both fans) Type Stock Colour Airflow performance (m 3 /h) db(a) Controller Flush Box Ref. No. Heat recovery Extract mode 3m HRV Stock Stock mode (max) (max) (max) Ref. No. Ref. No. HR B Beige W HR500X Beige W

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications. Centra dmev Unit 62kg* carbon 80% energy E S P l i g i b l e Q P P E N D I X Part F compliant, System 3 IPX4 rated Continuous mechanical extract. Constant volume option. SP ppendix Q eligible - Low SFP

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Model: Kair Whole House Ventilator Model Number: KHRVWH2000 Installation, Maintenance Instructions and User Guide Unit 6 Chiltonian Industrial Estate 203 Manor Lane, Lee, London. SE12 0TX Tel: 08451 60

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

HR200WK Through the wall Heat Recovery Ventilator

HR200WK Through the wall Heat Recovery Ventilator HR200WK Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions Stock Ref No:- HR200WK 14120020 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q. Specific

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz

More information

Centrifugal extract and condensation control fans

Centrifugal extract and condensation control fans Approvals: BEAB CE 3yr Guarantee Zone 1 Zone 2 The Premier range of pressure developing fans is designed specifically for domestic applications, where longer duct runs are required. Key features Type:

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. CI/SfB (57.7) 3rd Edition WINNER2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. Lo-Carbon Centra Allowing you to help the environment

More information

Mini fans MiniVent M1/100

Mini fans MiniVent M1/100 Mini fans MiniVent M1/100 M1/100 Mini fans of highest quality. Design and performance of the MiniVent M1/100 sets the standard for the mini fans range. M1/100 Performance curve high speed The excellent

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions HR100R Please leave these instructions with the user Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery Installation and Servicing Instructions Contents Section Page 1.0 Introduction 4

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini... Contents How to choose Recovery Ventilation type?............................................3 How do HRV, ERV and TRV Systems work?............................................4 Types of installations..............................................................5

More information

Introducing the RetroVent

Introducing the RetroVent Fans For Life Introducing the RetroVent Features Benefits Made in the UK Flying the flag for UK manufacturing, lower carbon footprints and total control over quality Tubular heat recovery cell Designed

More information

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2 INTEGRA PLUS Installation and Wiring Instructions Stock Ref. N INTEGRA PLUS 437666 230V~ 50Hz ABC PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX2 VENT-AXIA

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

ENERGY RECOVERY VENTILATION (ERV)

ENERGY RECOVERY VENTILATION (ERV) Home/Other Products/Obsolete Ranges ENERGY RECOVERY VENTILATION (ERV) 2 model sizes covering 500 to 1500m3/hr Choice of 90% or 55% efficient aluminium energy recovery cell High performance EC/DC motors

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra CI/SfB (57.7) 2nd edition Lo-Carbon Quadra Vent-Axia Quadra An Evolution in Residential Ventilation, Designed especially for Social Housing One fan fits all Happy Installers The fan that fits anywhere,

More information

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions HR100R Please leave these instructions with the user Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery Installation and Servicing Instructions 2 Contents Section Page 1.0 Introduction

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. VA100 Lo-Carbon RANGE 100mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 31 59 - LP 44 31 60 - XP 44 31 61 - LT 44 31 62 - XT 44 31 63 - LHTP 44 31 64 - XHTP 220-240V~50Hz PLEASE

More information

CI/SfB (57.7) 2nd edition

CI/SfB (57.7) 2nd edition CI/SfB (57.7) 2nd edition Sentinel Totus D-ERV Range Following on from the highly successful award winning Sentinel demand ventilation system, Vent-Axia has taken the next step by incorporating the Sentinel

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

Sentinel Demand Energy Recovery Ventilation

Sentinel Demand Energy Recovery Ventilation Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Lo-Carbon SELV Tempra

Lo-Carbon SELV Tempra Lo-Carbon SELV Tempra THROUGH THE WALL HEAT RECOVERY FAN Installation and Wiring Instructions DRAFT Stock Ref. N 444368 Pullcord. (SVP) 444369 Timer. (SVT) 444370 Humidistat -Timer Pullcord. (SVHTP) 220-240V~50Hz

More information

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Integra Integra Plus EC MVHR Installation & Commissioning Stock Ref. N 437666EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT. Copyright 2009 Vent-Axia Limited. All rights reserved.

More information

Silhouette Installation and Wiring Instructions

Silhouette Installation and Wiring Instructions Silhouette Installation and Wiring Instructions Stock Ref. N 45 40 55B (100B) 44 51 61 (125B) 45 40 59B (150X) 45 40 56B (100T) 44 51 62 (125T) 45 40 60B (150XT) 45 40 57B (100HT) 44 51 63 (125HT) 45 40

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition By Appointment to H.M. The Queen Suppliers of Unit Ventilation Equipment Vent-Axia, Crawley, West Sussex VENT-AXIA CONTACT NUMBERS Free technical, installation and sales advice

More information

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. Fresh air unit ALB ALB it s simple and so easy! Air supplied through a heater and filter in a single unit. The ALB fresh air units from Helios provide comfortable room temperatures. Fresh outside air is

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

Positive Input Ventilation

Positive Input Ventilation The UK s Leading Ventilation Company Positive Input Ventilation Edition 1 www.vent-axia.com/positive-input-ventilation We re here to help... Positive Input Ventilation Solutions designed especially for

More information

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan Installation and Wiring Instructions Stock Ref. N 427485B (P) 427486B (T) 427487B (HT) 427488B (TM) FAN UNITS 12V DC SELV (CLASS III) CONTROLLERS

More information

BATHROOM EXTRACT FANS SILENT-100 Series

BATHROOM EXTRACT FANS SILENT-100 Series SILENT-1 Series Range of axial extractors with airflow rates of 95 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz abc EXTRACTOR HOOD Please read all the instructions carefully before starting the installation Model Stock Ref Napoli 120812 Napoli Plus (white) 436083 Napoli Plus (Silver) 436084 230 / 240V 50Hz PLEASE

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans The Silent Range Pure Elegance & Tranquillity The widest range of ultra quiet silent fans The most advanced SILENT technology delivering the highest extract performance. 1 Your first choice for ventilation

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073Q.doc Sentinel Kinetic MVHR and Kinetic Plus MVHR Operation & Monitoring Stock Ref. N 438222 Kinetic B 438222A Kinetic BS 443319 Kinetic

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Window & Roof Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456165A (9" WW) 456168A (9" RF) 456173A (12" WW) 456176A (12" RF) WIRELESS 456169A (9" WW) 456172A (9"

More information

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES The Range 1 HIGHEST INDOOR AIR QUALITY IN NEW HOMES NUAIRE S Q-AIRE Innovation at its best Since our inception in 1966, we have pioneered a number of new ventilation strategies and products now widely

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

5 year fan housing and motor warranty

5 year fan housing and motor warranty MODEL SWF SIDEWALL CENTRIFUGAL FAN MODEL FEATURES Exhaust air up to 416 CFM with static pressure capabilities to 1.5 w.g. Galvanized steel casing with black backed enamel coating Pre-wired junction box

More information

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5 S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE The Quietest Extractors in the World in their Category Lp 26,5 db AXIAL FLOW FANS Series -1-1 16182 6376-2 -3 NEW Installation examples Axial fl

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS. TWIFAS COMPACT & POWERFU, IDEA FOR ARGER ROOM APPICATIOS WHIST MAITAIIG OW OISE EVES. 9 85 8 5 Speed Control TWI FAS BEEFITS COMPACT & POWERFU Small design, high performance up to 5I/s - ideal for larger

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan Simply Silent Contour 4 (100mm) Axial Extraction Fan Suitable for bathrooms, toilets, shower and utility rooms Controls humidity, odours and mould growth Sleek low-profile design, wall or ceiling mounting

More information

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS ENERGY-SAVING VENTILATION SOLUTIONS TO IMPROVE INDOOR AIR QUALITY Quality Features Built Into Every Model Compact

More information

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. Centra o-carbon COTIUOUS EXTRACT FA Installation and Wiring Instructions Stock Ref. 44 29 54 Timer (T) 44 29 55 Humidistat-Timer (HT) 44 30 45 Humidistat-Timer- Pullcord. (HTP) 220-240V~50Hz PEASE READ

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz T-SERIES Wall & Panel Models Installation, Set-up and Operating Instructions Stock Ref. Nos. WIRED 456166A (9" WL) 456167A (9" PL) 456174A (12" WL) 456175A (12" PL) WIRELESS 456170A (9" WL) 456171A (9"

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073S.doc Sentinel Kinetic MVHR and Kinetic Plus MVHR Operation & Monitoring Stock Ref. N 438222 Kinetic B 438222A Kinetic BS 443319 Kinetic

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

Warnings, Safety Information and Guidance

Warnings, Safety Information and Guidance EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB

More information

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition.

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition. The UK s Leading Ventilation Company Lo-Carbon Revive 2nd Edition www.vent-axia.com/revive A fan designed to meet the needs of Social Housing Landlord Can be installed in a kitchen or bathroom. No filter

More information

Sentinel Kinetic MVHR RANGE

Sentinel Kinetic MVHR RANGE V:\Technical\ARTWORK\Fitting & Wiring\Word Files COMPLETE\442073 W.doc Sentinel Kinetic MVHR RANGE User Instructions Stock Ref. N 438342 Kinetic V 438222 Kinetic B Right 438222L Kinetic B Left 443319 Kinetic

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR Central ventilation system ZLS Central ventilation system ZLS-DV EC according. ZLS-DV EC is the ideal central ventilation system in multi-storey construction according. EXTRACT AIR OUTSIDE AIR FIRE PROTECTION

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG VORTICE PUNTO RANGE ➀ ➁ ➂ ➃ For intermittent or continuous ventilation of bathrooms, toilets, kitchens or utility rooms in domestic or commercial properties. 82 models available with or without the option

More information

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year. Air circulation Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year. At work employers are legally obliged to ensure that during working hours

More information

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

LANDLORDS & LETTINGS VENTILATION SOLUTIONS LANDLORDS & LETTINGS VENTILATION SOLUTIONS CREATING A HEALTHY INDOOR ENVIRONMENT CONTENTS INTRODUCTION... 3 WHY IS VENTILATION IMPORTANT?...4 CURE CONDENSATION FOR GOOD... 5 THE DRIMASTER RANGE... 6 SINGLE

More information

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position. VMD Range Features & Benefits Performance range up to.4m /s Motor Insulation Class F Anodised aluminium pentapost frame Double skinned panels Compact direct drive units Electric heater battery Built-in

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

ECO dmev Decentralised MEV

ECO dmev Decentralised MEV ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the

More information