1 1 DRAFT HPW-DUST HIGH PRESSURE DUST SUPPRESSION SYSTEMS Dynaset HPW Dust high pressure suppression system is based on HPW-pump and is specially designed to prevent dust emissions at crushing, pulverizing, demolition or to any process of dusting materials. HPW dust high pressure suppression system can be used effectively applications like quarries, recycling and waste management, material handling etc. Dynaset wide HPW pump series produce needed water pressure and flow to different dust suppression application. High pressure water mist is spayed via dust suppression nozzles round the dust particles. The weight of the water bounded dust particles increases multiply that makes them fall down. Low water consumption is achieved by tiny water mist that do not irrigate machine and surroundings wet. Various applicable forms of high power jets are available, turbo jets or dousing umbrella for area suppression, falling debris etc. Dynaset HPW Dust high pressure Suppression system is easy to install to any machine and is fully controlled from cabin. The system has next benefits: - Extremely low water consumption, no need for large reservoir. - Microscopic water binds dust particles effectively. - No mud forming on machinery surface. - Good visibility, clean and better breathing air. - Saves health care expenses. OPERATING INSTRUCTIONS

2 2 TABLE OF CONTENTS 1. SAFETY PRECAUTIONS AND WARNING STICKERS 3 2. GENERAL 4 3. HPW-DUST BOUBLE BASIC COMPONENTS A HYDRAULIC ACTUATOR VALVE KIT CONTROL WIRING IN DUST SUPPRESSION SYSTEM Dust suppression system with dual water circuit INSTALLATION TO DIFFERENT HYDRAULIC SYSTEMS Open centre hydraulic system with variable displacement pump Dust suppression system with a dual water circuit Dust suppression system with a single water circuit Close centre hydraulic system with variable displacement pump Dust suppression system with a dual water circuit Dust suppression system with a single water circuit INSTALLING COMPONENTS NOZZLE SPRAY ANGLE THEORETICAL COVERAGE HYDRAULIC ACTUATOR VALVE INSTALLATION OPERATION PUMPING FLUIDS HYDRAULIC FLUIDS MAINTENANCE PRODUCT DISPOSAL MANUFACTURER S LIMITED WARRANTY DECLARATION OF CONFORMITY NOTES 19

3 3 SAFETY PRECATIONS Operating with DYNASET HPW dust high pressure suppression system, user has to conform to all safety regulations concerning pressurized equipment. Hydraulic circuit has a highpressure over 220 bar. EQUIPMENT TECHNICAL CONDITION HAS TO PAID SPECIAL ATTENTION TO. In order to avoid accidents all operators and maintenance personnel must act in compliance with the laws, regulations and recommendations the high pressure hydraulics, electricity and work safety issued by local authorities. EXTERME CLEANLINESS MUST BE MAINTAINED WHEN CARRYING OUT ANY DISSASSEMBLING OR REPAIR OF HPW UNIT AND HYDRAULIC SYSTEM. THIS IS CRUCIAL TO ENSURE SAFE, RELIABLE AND LONG-LIFE OPERATION OF THE EQUIPMENT. The pressure in hydraulic fluid circuit is considerably high and hydraulic system has to maintain regularly. Especially couplings, valves and hoses have to be tight and clean as well as kept under constant observation. Check and fix possible leakages of pressure and hot blowouts immediately avoiding user and bystander injuries. In order to exclude possible accidents, it is not allowed to clean or inspect HPW unit when hydraulic fluid circuit is pressurized. Prior to any cleaning, inspection and service hydraulic system of your carrier machine must be stopped and all hydraulic fluid circuits depressurized. Wear appropriate clothing and safety equipment such as goggles, ear and eye protection, safety shoes at all times when operating with the HPW dust high pressure suppression system. Beware of warm oily machinery parts. Operators and maintenance personnel must always comply with local safety regulations and precautions in order to close out the possibility of damages and accidents. All installation and service hydraulic and electric equipment must be performing experienced personnel only. Preventing freezing nozzles, water circuit and pipeline. Draining and air flushing have to perform before ambient temperature reaches 0 C (32 F) or lower. WARNING STICKERS Dynaset dispatch department includes one (1) warning sticker bag per one (1) main product. Product recipient is obligated to fix determinate warning sticker to Dynaset product. Attach sticker to visible and appropriate place or close to Dynaset product where it s easily seen. Before attaching sticker, clean surface with solvent detergent. READ OPERATING INSTRUCTIONS. BEWARE OF HIGH PRESSURE KEEP FROM FREEZING. USE EAR PROTECTOR AND SPLATTERS. GLOGGLES.

4 4 GENERAL HWP High Pressure Dust Suppression system forms microscopic water mist which means low water consumption and low costs. Mist-like atomized water binds even the smallest dust particles and makes them heavier to falling down in a controlled manner. Dust suppression system avoid soiling of surroundings, inhibits mud sagging keeping the working area almost dry. The compact hydraulic operated high pressure pump is easily mounted onto the machine. HPW pump is controlled by electric ON/OFF valve on machinery cabin. Hydraulic valve kit controls the water pressure with pressure reducer and the oil flow limiter. Pressure reducer and solenoid valve to appropriate application control nozzles water flow. Pressure compensated oil flow-limiter controls the biggest running speed of the HPW-pump. Excavator fitted Dynaset HPW-Dust suppression system are dual power stage type. Continuous basic dust suppression is supplement with a high power mode, which is used as frequently as necessary to suppress dust created during demolition by fallen debris by bulk-loaded dump on a truck s platform etc. Technically dual stage power output is implemented in two different ways: 1. In a Dual Water Circuit (DWC), both basic and high power levels use individual high-pressure nozzle pairs. The high power dust suppression is switched on by activating separate water solenoid valve. High power suppression nozzles can be the first time coarsely pre-aimed to an assumed dust source according to task demand and conditions. Exact aiming is done after the experiment. 2. In a Single Water Circuit (SWC), the same nozzle pair is for both basic and high power dust suppression, using two separate hydraulic flows one for each power level of dust suppression. Prior to switching on the dust suppression, operator have to aim the attachment with dust suppression nozzles to a dust source. Front loader s bucket or mobile crusher s feed hopper and conveyors can be equipped with dust suppression-nozzle pipe(s) of a single water circuit mode continuous mode, dust suppression system HPW200 Dust. Nozzles: 8 x (1,6 lpm 120 )

5 5 HPW-DUST DOUBLE BASIC COMPONENTS HPW90 dust double, PC-SAE 1"-24V, D PV-SAE HPW90/ DUAL WATER CIRCUIT SYSTEM (DWC) components ready for installation and for instantly use, including following components: HPW-PUMP 1., PRESSURE REDUCING VALVE 2.2, FLOW LIMITING VALVE 2.3 and SOLENOID VALVE 2.4. (spraying On) In OC-hydraulic systems, HPW-pump is operated under constant hydraulic pressure. The output water flow and eventually hydraulic flow is rated by the size of installed water nozzles. The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression. HPW200 dust double-dwc, D HOSE HPW200/30-45 HAND SPRAY PISTOL FILTER ELEMENT NOZZLES: 2 x 6504 (12 lpm 65 ) 2 x 6502 (6,4 lpm 65 ) PRESSURE RELIEF VALVE 2.4 SOLENOID VALVE (HIGH PRESSURE) 2.3 FLOW LIMITING VALVE ON / OFF -VALVE (CONTINUOUS) - PUSH AND PULL BUTTONS - INDICATOR LAMP - SOLENOID PLUGS - CONTROL WIRING

6 6 HPW-DUST DOUBLE BASIC COMPONENTS Following Hydraulic High Pressure Water Pumps (HPW) are widely used in Dynaset high-pressure dust suppression systems: - HPW 200/30-45 dust. 4 x 6,4 l/min nozzles. - HPW 200/30-45 dust double. Double power spray 20/30 lpm. - HPW 220/50-70 dust double. Double power spray 30/50 lpm. - HPW 180/ dust double. Double power spray 30/90 lpm. - HPW 130/ dust double. Double power spray 30/180 lpm. HPW 200/30-45 HPW 130/ MAIN PARTS HPW90 Dust double, PC-SAE 1"-24V oc. D Water nozzle with required fittings is suitable for both continuous and intermittent high power modes Nozzles left to right: - No. 1-4, (6,4 lpm 200bar 110º) for intermittent high power mode. - No. 5 and 6, 2 x R3/8" (51 lpm 70bar) for continuous mode. - No. 7 nozzle attaching clamp. Water solenoid valve for occasional high-pressure dust suppression with required fittings. Dust suppression nozzles installed to a nozzle pipe. High pressure spray pistol with 10m hose. Filter to water intake (claw coupling) from pressurized water supply, i.e. water from hydrant, max. pressure 5 bar. Water intake hose with strainer and claw coupling from machinery s separate water tank.

7 7 A HYDRAULIC ACTUATOR VALVE KIT Valve kit for Open centre hydraulic systems includes pressure compensator PV-SAE pos When installing to close centre hydraulic system, concerned pressure compensator is not required. HYDRAULIC VALVE KIT for a DUAL WATER CIRCUIT SYSTEM (DWC) includes following components: PRESSURE REDUCING VALVE 2.2, FLOW LIMITING VALVE 2.3 and SOLENOID VALVE 2.4. In OC-hydraulic systems, HPW-pump is operated under constant hydraulic pressure. The output water flow and eventually hydraulic flow is rated by the size of installed water nozzles. The flow limiting valve is adjusted at factory to the throughput required by high power dust suppression. 2.3 PC-SAE 3/4" 2.4 Solenoid valve 2/2 NC 2.2 Pressure reducer Flow limiter R3/4 u s B 2.1 LS T 2.4 LS A P OC-HYDRAULICS P HYDRAULIC VALVE KIT for SINGLE WATER CIRCUIT (SWC) SYSTEM provides two separate hydraulic flows, one for both power level of dust suppression. HPW200 dust double-dwc, D P On / Off -valve Solenoid-valve Flow limiting valve T Pressure relief valve Control valve kit for single water circuit system (SWC).

8 8 A HYDRAULIC ACTUATOR VALVE KIT HYDRAULIC VALVE KIT for SINGLE WATER CIRCUIT SYSTEM (SWC): Valve kit includes an adjustable FLOW LIMITING VALVE 2.5 for continuous dust suppression, LS Valve with FLOW LIMITER 2.6 for high power dust suppression (adjusted in factory), two SOLENOID VALVES 2.7 and 2.8 respectively and PRESSURE RELIEF VALVE LS Q2 LS T Q2 P OC-HYDRAULICS 2.5 Q1 P 2.6 Q1 By activating the solenoid valve 2.7, the continuous dust suppression is being started. Water flow is rated by setting of flow limiting valve 2.5, which can be re-adjusted within certain limits. Hydraulic fluid flow Q1 is directed to the pressure port of HPW-pump through above components and fixed flow limiter The High power dust suppression is switched by activating the solenoid valve 2.8 when system s operation (primary hydraulic flow and secondary water flow) is rated tothe fixed flow limiter setting 2.6. Pressure relief valve protects the equipment against damages. CONTROL WIRING IN DUST SUPPRESSION SYSTEM DUST SUPPRESSION SYSTEM WITH DUAL WATER CIRCUIT HPW-PUMP S ON-OFF SWICTH + 24 VDC 2 x 1,5 mm2 red yellow HPW-pump is switched on by activating the hydraulic solenoid valve 2.4. The switch is to be located in a suitable place inside of the machinery cabin. ON-OFF SWITCH OF BASIC DUST SUPPRESSION IN CABIN.

9 9 CONTROL WIRING IN DUST SUPPRESSION SYSTEM DUST SUPPRESSION SYSTEM WITH DUAL WATER CIRCUIT HIGH POWER WATER SOLENOID VALVE S BUSH-BOTTON SWITCH + 24 VDC VDC 0 2 x 1,5 mm2 1.3 High power dust suppression is switched on by activating the water solenoid valve 1.3. Spring-loaded push-on button is recommended to place on a boom s control stick. 24 VDC from the 10 A fuse By activating either of hydraulic solenoid valves with a rocker or other 3-pole switch, an operator directs the hydraulic flow of chosen power mode to the HPW-pump s pressure port. The switch can be located onto the dashboard or any other user-friendly position. When the switch is in the mid-position, both solenoid valves are disengaged and HPW-pump stopped. INSTALLATION TO DIFFERENT HYDRAULIC SYSTEMS HPW-pump is to be connected to hydraulic system of carrier machine, as well as to pumping fluid circuit. HPW can be installed with no particular efforts to system based on either constant or variable displacement hydraulic pump, as well as to closed hydraulic systems. ATTENTION! Check the ports of your HPW-pump and connect it to hydraulic and pumping fluid circuits according to their markings! If the hydraulic pressure line will be connected by accident to the return port and return line correspondingly to the pressure port, it will not cause any harm to HPW-pump, however pump will not operate. In order to reduce both pressure pulsation and return line oscillation, the flexible hose with textile fabric cord is recommended to be used in return line to protect from damage low pressure units, such as oil cooler. Prior to connecting HPW-pump to hydraulic circuit, compatibility of used equipment should be ensured. Hydraulic pressure and flow rate produced by hydraulic circuit should meet values demanded by your HPW-pump. Refer to the technical specifications.

10 10 INSTALLATION TO DIFFERENT HYDRAULIC SYSTEMS OPEN CENTRE HYDRAULIC SYSTEMS WITH VARIABLE DISPLACEMENT PUMP DUST SUPPRESSION SYSTEM WITH A DUAL WATER CIRCUIT Nozzles for continuous dust suppression mode. High power dust suppression nozzles. Water solenoid valve for high power dust suppression. High-pressure spray gun. AN ALTERNATIVE: Water reservoir, intake hose, filter. PC-SAE Water supply from water hydrant (Max. pressure 5 bar). DUST SUPPRESSION SYSTEM WITH A SINGLE WATER CIRCUIT. Dual mode high dust suppression nozzles. High-pressure spray gun. AN ALTERNATIVE: Water reservoir, intake hose, filter. PC-SAE Water supply from water hydrant (Max. pressure 5 bar).

11 11 INSTALLATION TO DIFFERENT HYDRAULIC SYSTEMS CLOSE CENTRE HYDRAULIC SYSTEMS WITH VARIABLE DISPLACEMENT PUMP DUST SUPPRESSION SYSTEM WITH A DUAL WATER CIRCUIT Nozzles for continuous dust suppression mode. High power dust suppression nozzles. Water solenoid valve for high power dust suppression. High pressure spray gun. AN ALTERNATIVE: Water reservoir, intake hose, filter. Water supply from water hydrant (Max. pressure 5 bar). DUST SUPPRESSION SYSTEM WITH A SINGLE WATER CIRCUIT. Dual mode high dust suppression nozzles. AN ALTERNATIVE: Water reservoir, intake hose, filter. Water supply from water hydrant (Max. pressure 5 bar).

12 12 INSTALLING COMPONENTS Hydraulic high-pressure water pump HPW is recommended to install onto excavator s upper structure behind the boom in order to easy pressure hose lying along the boom down to the nozzles. Install pump with rubber cushions to reduce noise and vibration. Water supply hose should be brought to the HPW-pump in the way excluding the hose to be drawn under the crawler track of the machinery. The water supply hose must constantly be insight of an operator. Water reservoir (if used) is recommended to lock on an excavator. Water supply hose, provided with filter, is brought in form the upper lid or hatch. 4 x High power dust suppression nozzles should be fastened to a attachment as well. Position of the nozzles should be chosen to cover as wide dusting area as possible. Direct nozzles to the dust source so that HPW-PUMP all dust are rounded by the water mist. See picture right below. Rotating table or foot of a attachment is suitable for the purpose. Nozzles should be shielded with detachable covers against impacts. High power dust suppression is controlled by means of the water solenoid valve, which is recommended to install to a basic boom s end in suitable place to be kept clean and intact. AN ALTERNATIVE: Water reservoir 2 x NOZZLES x 4 MATERIAL FLOW 2 x High power dust suppression nozzles should be fastened to an attachment. Position of the nozzles should be chosen to cover as wide dusting area as possible. Rotating table or foot of an attachment is suitable for the purpose. WATER MIST + DUST Recommended nozzles e.g. for crushing, pulverizing or demolition: (48lpm 200bar 25º, Oc ) (26 lpm 200 bar 25º, Oc ) MATERIAL FLOW

13 13 INSTALLING COMPONENTS Basic dust suppression nozzles should be installed to an attachment. Their position must ensure water jetting immediately into the processing zone / area, for instance straight into the zone between crushers jaws, see the page 1. Install nozzles into the inter-jaw zone, crusher s shaft must be provided with a water channel on 6-10mm. Additional swivel joint is required for the water supply. If there is no possibility to use swivel water joints, basic dust suppression nozzles is the best place on rotating table s rim. 2 x 2 x Nozzles for continuous dust suppression mode attached to clamps. High pressure dust suppression nozzles are effective alternative as well. Nozzles for continuous dust suppression mode equipped with swivel joints on hose branch. 4 x Nozzles for continuous dust suppression mounted to the crusher s conveyor with clamps.

14 14 NOZZLE SPRAY ANGLE THEORETICAL COVERAGE 65º (6504) 25º 1,1 m 0,5 m Area covered 1,1m x 2m = 2,2 m². If 4 nozzles: 4 x 2,2m² x 0,6 = 5,28 m². Area covered 0,5 m x 2 m = 1,0 m². If 8 nozzles: 8 x 1,0 m² x 0,6 = 4,8 m². Figures are only exemplifying, presenting theoretical coverage of spray patterns at various distances from nozzle orifice. Used pressure level, water temperature, viscosity and water surface tension have their affects to spray angle and distance. Prior to use different kinds nozzles with DYNASET high pressure dust suppression system, please be kindly requested to contact nearest DYNASET representative for an advice. 0 m 1 m 2 m 3 m 4 m HYDRAULIC ACTUATOR VALVE INSTALLATION Hydraulic valve unit, by means of which the necessary power is taken and brought to the Dynaset HPW-pump, is recommended to install into the hydraulic pump compartment of a carrier machine. The installation of the hydraulic actuator valve of a dual water-circuit dust suppression system is displayed on the attached pictures. Refer also to hydraulic diagrams on pages 9 and10. Pressure compensator installed to a pressure port of the main hydraulic pump. An installation of a valve unit include of pressure reducing valve, flow limiter valve and solenoid valve.

15 15 OPERATION Having started a machinery and job - for instance, demolition of the building - an operator stars the basic dust suppression by activating a hydraulic solenoid valve. Basic dust suppression nozzles catch the dust straight at its source. High power dust suppression can be used to kill the dusting of bigger objects - a debris pile, fallen fragment, etc. An attachment with nozzles should be aimed to the dust-emitting object by activating either the water or hydraulic solenoid valve - depends on system s structure, see pages 9-10). The high power dust suppression is intended for discontinuous use, but if the water pipeline is available, the high power mode can be used on continuous basis when necessary. PUMPING FLUIDS High-pressure dust suppression nozzles and HPW-pump required at least mesh 80 (177 μm) water intake strainer. Observe strainer condition regularly. If any nozzle s spray form going to be varying or to be clogged, the nozzle should detach and flushed with clean water against the working flow direction. Flush suction strainer with water or change it to the new one. Water based fluids and seawater can be pumped without any special arrangements, however the pump MUST BE FLUSHED AND CLEANED THOROUGHLY after a working shift with clean sweet water. Same rule applies to pumping of gelatin and depositing fluids. After having done your job, flush HPW-pump with clean water or suitable solvent. Solvents, fuels and oils can be pumped without any special arrangements. Fluids with abrasives or high content of solids can be pumped as well, but should be kept in mind, that HPW-pump s service lifetime is considerably shortened. Pls. note that DYNASET HDF-pump series is especially designed for pumping of abrasive fluids. When HPW-pump is going to be used as a self-priming unit with a special or high viscosity liquid, the flow and self-priming conditions should be evaluated. If the self-priming property cannot be reached, pumping liquid is to be fed with certain pressure (refer to the TECHNICAL SPECIFICATIONS), or the pump should be used at lower hydraulic flow. Furthermore, if pumping solution is aggressive to NBR-rubber, special seals must be used. HPW-models made of special materials or with coated parts are available by request. ATTENTION: Preventing freezing nozzles, water circuit and pipeline at HPW dust high pressure suppression system, draining and air flushing have to perform before ambient temperature reaches 0 C (32 F) or lower. HYDRAULIC FLUIDS Wide range of standard hydraulic fluids can be used with the DYNASET hydraulic equipment. Subject to the operating temperature, following mineral hydraulic oils are recommended: ISO VG 32S for oil s operation temperature up to 70 C; ISO VG 46S for oil s operation temperature up to 80 C; ISO VG 68S for oil s operation temperature up to 90 C. Synthetic and bio-oils can be used as well if their viscosity characteristics and lubricating efficiency are corresponding to above mineral oils. Automatic transmission fluids and even engine oils can be used, provided that they are allowed to be used in hydraulic system of your carrier machine. Prior to use special hydraulic fluids a with DYNASET equipment, please be kindly requested to contact nearest DYNASET representative for an advice.

16 16 MAINTENANCE If any nozzle s spray form going to be varying or nozzle clogged, the nozzle should detach and flush with clean water against the working flow direction. Flush suction strainer with water or change it to the new one. Due to small number of moving parts, in normal operating conditions HPW-pump does not require any other service, except replacement of sealings or occasionally of water valves, which depends on content of abrasives in pumping fluid, as well as on cleanliness of hydraulic oil. Check constantly whether the fluid dropping from pump s leakage detectors is growing and replace sealing in proper time to exclude intermixing of hydraulic oil and pumping fluid. To enable the easy surveillance, pump should be kept clean. Observe also couplings, valves and hoses that they are tight with no bleeding. Clean pump fluid filter and suction strainer guarantee long components life cycle. Prior to any cleaning, inspection and service hydraulic system of your carrier machine must be stopped and all hydraulic fluid circuits depressurized. WHEN CARRYING OUT ANY DISASSEMBLING OR REPAIR OF HPW-PUMP, ABSOLUTE CLEANLINESS MUST BE MAINTANED TO ENSURE RELIABLE AND TROUBLE-FREE OPERATION OF YOUR EQUIPMENT. PRODUCT DISPOSAL Conform to waste legislation, regulations and recommendations in waste disposal and waste recycling issued by local authorities. 1. Precondition: Product is permanently useless or beyond repair. Before transportation get off all used agent (oil, cooling liquid) and dirty filters. Items requiring special handling can normally be done by authorized waste management facility, if not: Separating the base materials, iron, copper, steel, electronics, removing paint, polyester resin, and insulation tape and/or plastics residues from all components. This waste material can now be recycled. 2. Deliver the recycling and waste material to waste management facility. Note! Customer can send the DYNASET equipment for reuse or recycling to the Dynaset Oy or to other location determinate by Dynaset representative. Customer pays shipping cost. Equipment must be adequately packed for shipment. Shipment documents must contain purchaser s name, contact information, equipment type and serial number.

17 17 MANUFACTURER S LIMITED WARRANTY 1. Warranty coverage All hydraulic accessories manufactured by DYNASET OY are subject to the terms and conditions of this limited warranty. Products are warranted to the original purchaser to be free from defects in materials or workmanship. Exclusions from warranty are explained in item Beginning of warranty period Warranty period begins from the delivery date of the product. Delivery is considered to be done on the date when installation has been accomplished or purchaser has taken the product in use. Product is considered as taken in use at the date when DYNASET OY has delivered the product to purchaser, unless separately agreed otherwise by written agreement. 3. Warranty period Warranty period is twelve (12) months based on maximum of 2000 hours usage during this time period. In cases where the system is provided complete with certain special components (e.g. drive unit), those components are considered as a subject to their manufacturer s warranty. 4. Warranty procedures Immediately upon identifying a problem which purchaser believes to be a failure subject to the product s limited warranty, purchaser must contact primary to the seller of the product. Contact must be made as soon as possible, latest thirty (30) days after the problem was identified. Seller and/or manufacturer technical staff determines the nature of the problem primarily by phone or . Purchaser commits to give necessary information and to perform routine diagnostic procedures in order to determine the nature of the problem and necessary procedures. 5. Warranty repairs If the product is found to be defective during the warranty period, DYNASET OY will, at its option, either repair the product, author it to be repaired at its authorized workshop or exchange the defective product. If the product must be repaired elsewhere than premises of DYNASET OY or authorized workshop, all costs excluded from this warranty (traveling and waiting hours, daily allowance, traveling expenses and uninstallation/reinstallation costs) will be charged from the purchaser. If the problem is not covered by this limited warranty, DYNASET OY has the right to charge purchaser of troubleshooting and repairing. 6. Delivery terms of warranty repair If the product is found possible to be defective under this limited warranty and it needs to be repaired, DYNASET OY gives Warranty Return Number (WRN). Items being returned must be shipped, at the purchaser s cost, adequately packed for shipment, to the DYNASET OY or to other location authored by DYNASET OY. Shipment documents must contain: - Purchaser s name and contact information - Receipt of original purchase - WRN code - Problem description 7. Warranty of repaired product Warranty period of the product repaired under this limited warranty continues to the end of original warranty period. 8. Exclusions from warranty This warranty shall not apply to: a. Failures due to normal wear and tear, improper installation, misuse, abuse, negligence, purchaser selection of improper product to intended use, accident, improper filtration of hydraulic oil or intake water or lack of maintenance b. Cost of maintenance, adjustments, installation or startup c. Coating, hydraulic oil, quick couplings and interconnection hoses (internal or external to system assemblies) d. Products altered or modified in a manner not authorized by DYNASET OY in writing e. Products which have been repaired during warranty period by others than DYNASET OY or its authorized workshop f. Costs of any other damage or loss, whether direct, indirect, incidental, special or consequential, arising out of the use of, or the inability to use, the product g. Telephone or other communications expense h. Product that is used in exceptional conditions, considered to cause excessive wear and tear i. Faults caused by nature phenomenon s like flood, thunder, etc. DYNASET OY, all rights reserved

18 18 EC DECLARATION OF CONFORMITY We hereby declare that the below-reference product design, structure and our manufacture form fulfills relevant, fundamental safety and health requirements with the provisions in the Council Directive on mutual approximation of laws of the Member States on the safety of machines. - Machine directive 2006/42/EC - Directive 97/23/EC European standards Pressure equipment. - LVD directive 2006/95/EC Apply conformity standards: - EN Safety of machinery Electrical equipment of machines. - CEN EN ISO 4413: EN ISO 4413:2010 Hydraulic fluid power - General rules and safety requirements for systems and their components. If device has changed by someone other than at the hands of manufacturer or his permission, this declaration is not valid. PRODUCT: HIGH PRESSURE DUST SUPPRESSION SYSTEMS ALL TYPE NUMBERS: HPWxxxxxxxxxx-xxxxxxx-xxxxxxx-xxxxxxxx-xxxxxxxx YLÖJÄRVI DYNASET Oy Timo Nieminen R&D Manager

19 19 NOTES

20 20

Dynaset. High pressure dust suppression systems HPW DUST

Dynaset. High pressure dust suppression systems HPW DUST Dynaset High pressure dust suppression s HPW DUST Dust will be a big problem in future on demolition, quarrying, drilling, recycling, earth construction etc. business, without preventing actions. Why use

More information

Xaact Spot. Xaact Hot Spot

Xaact Spot. Xaact Hot Spot Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............

More information

SASE BULL 240C. Dust Collection System Manual

SASE BULL 240C. Dust Collection System Manual SASE BULL 240C Dust Collection System Manual www.sasecompany.com 800.522.2606 sales@sasecompany.com Contents 2 Symbols 3 Safety Instructions 3 Intended Use 4 Design of the Bull 240 5 Product Description

More information

2001 Smith Eastern Corporation

2001 Smith Eastern Corporation Automatic Spray Equipment Cleaning System User s Manual UG-45V Smith Eastern Corporation 10630-S Riggs Hill Road Jessup, Maryland 20794-9425 USA 301.497.7600 800.937.HVLP (4857) Fax 301.497.7613 cleaner@airverter.com

More information

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY

POWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY Vactor celebrates over 45 years as your powerful sewer cleaning partner. For nearly 50 years, Vactor Manufacturing has been the leader in building combination sewer cleaners with technological innovation

More information

1200 EVERYDAY PRESSURE WASHER. Instruction Manual. Model: PW If you have any questions or comments, please call our toll free

1200 EVERYDAY PRESSURE WASHER. Instruction Manual. Model: PW If you have any questions or comments, please call our toll free 1200 EVERYDAY PRESSURE WASHER Instruction Manual Model: PW0501400 If you have any questions or comments, please call our toll free 1-866-924-7626 PLEASE KEEP THE ORIGINAL BOX, PACKAGING AND RECEIPT. BEFORE

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODELS: CH1001-A Operator s & Installation Manual Release Date: August 9, 2002 Publication Number: 620914301 Revision Date: May 6, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd. TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih

More information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE XAACT Xtract 200 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00018 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important

More information

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

WHU WATER HEATING UNITS.  GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS WHU WATER HEATING UNITS GENERAL MANUAL MODEL KEY WHU Water Heating Unit Maximum heating power, kw Max. water inflow pressure, bar Voltage options GENERAL INFORMATION WHU water heater, producing hot water

More information

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT Sanitaire 10 GALLON Box Extractor SC6088 Series Part No. SC6088 Rev 2 (3/14) Owner s Guide IMPORTANT Do not return this product to the store. Call 1-800-800-8975* Monday - Friday 8:00 AM to 7:30 PM and

More information

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

How about Savings in Time, Money, Energy and Longer Life?

How about Savings in Time, Money, Energy and Longer Life? Chapter 17: The Value of Maintaining Evaporative Cooling Equipment 97 The Value 17 of Maintaining Evaporative Cooling Equipment 1. Cooling Tower Maintenance and Upgrades... What s in it for You? How about

More information

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and

More information

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS Enspeco AUTOMOTIVE REFRIGERANT MANAGEMENT SYSTEMS RMS 5000 INSTRUCTIONS The Enspeco Refrigerant Management System 5000 provides fast and efficient recovery, recycling and charging of automotive air conditioning

More information

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model) Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model) First Release... 6/18/96 Rev. C... 1/16/98 Rev. D... 5/01/00 Operating Instructions, Model 4400/VC (Rev. D, 5/01/2000)...

More information

Models Series Series

Models Series Series Models 31800-Series 31801-Series INDUSTRIAL DIAPHRAGM PUMPS 4 GPM/15 LPM FEATURES Self-Priming Easy Installation Can run dry without damage Low Amp Draw Flow to 4 GPM/15 LPM Compact Size Thermal Overload

More information

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions. COOL MIST ULTRASONIC HUMIDIFIER HC12W OWNER S MANUAL Read and save these instructions. 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE And neither are we. Always at the forefront of our industry, our goal is to

More information

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE XAACT Xtract 500 INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00015 Rev B 032912 1 CONTENTS: Machine Specifications............ 2 Record Important

More information

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Air Bear Accu-Fit TM. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE Air Bear Accu-Fit TM Media Air Cleaner TRION www.trioniaq.com Table of Contents Introduction... 1 Unit Selection Guide... 2 Installation...

More information

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056 MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL Call 888.896.8786 Model #: H056 IMPORTANT SAFE T SAVE THESE INSTRUCTIONS When using an electrical appliance, basic safety precautions should always be observed,

More information

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL KING COBRA 310 120V INFORMATION & OPERATING INSTRUCTIONS U. S. PRODUCTS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 56041963 IMPROPER USE OF THE MACHINE

More information

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is

More information

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa) Operation Pro Pack Portable Spray Pack - For use with Graco hand-held sprayers (except Fine-Finish sprayers) - - For portable spray applications of water-based and oil-based (mineral spirit-type) architectural

More information

ORIGINAL INSTRUCTIONS

ORIGINAL INSTRUCTIONS WARNING: Read the instructions before using the machine. POWER WASHER MODEL NO: JETSTAR 1950 PART NO: 7336010 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0617 - ISS 3 INTRODUCTION Thank

More information

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer the best

More information

DZ5080 US Index01 19/09/07 10:50 Page 2

DZ5080 US Index01 19/09/07 10:50 Page 2 www.rowentausa.com 2 1 13 12 3b* 3a 3c 11 3 3d* 10 9 4 5 6 7 8 DESCRIPTION 1 Burst of steam button 2 Spray button 3 Variable steam control a Dry ironing b Steam ironing c Self Clean d Autosteam * 4 Water

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic INSTRUCTIONS PERTAINING TO; RISK OF FIRE, ELECTRIC SHOCK OR HARM TO PERSONS IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic precautions should always be followed, including

More information

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle USE AND CARE GUIDE FOR MODEL MEK1, MEK15 Express Cordless Kettle IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed, including the following: 1. Read

More information

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and

More information

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector "The Most Powerful Dust Collector In Its Class... Guaranteed!" IMPORTANT INSTRUCTIONS DO NOT DISCARD I Thank

More information

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E E29976-00 FiberPRO 2.5 H Heated Spot Extractor Operator and Parts Manual 1001 Brown Avenue Toledo, Ohio 43607-0127 Customer Service: 888-GO-BETCO Fax: 800-445-5056 Technical Service: 877-856-5954 www.betco.com

More information

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual AIC Brazed Plate Heat Exchanger Operating and Instruction Manual Advanced Industrial Components Page 1 of 8 Customer Service Call: 1-888-738-1350 1.0 Installation 1.1 Mounting/support unit: a) On a shelf

More information

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them

K 2.900M. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them K 2.900M Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them. 5.961-933.0 01/07 2 Dear Customer, Please read and comply with these instructions

More information

Owner s. Coolerr. comply. To view

Owner s. Coolerr. comply. To view Owner s Manual EC220W Evaporative Coolerr IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to install or use this evaporative cooler. For your safety, comply with all safety

More information

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle! Trumatic E 7 7 2 9 9 4 Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7 To be kept in the vehicle! Trumatic E 2400 (Australia) Table of contents Installation example...

More information

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX FP13-15-GB SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX 1 Attention: Read all instructions carefully before installing filter pump. TABLE OF CONTENTS Instruction...... 2-3

More information

THERMAL SYSTEMS, INC. Installation and Operation Manual

THERMAL SYSTEMS, INC. Installation and Operation Manual THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016 1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never

More information

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron. User Manual Warranty Oliso, Inc. warrants that for a period of one year from the date of the original purchase, this product will be free from defects in material and workmanship, when utilized for normal

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

KB Operating Instructions. Before first use of the unit Please read these /07

KB Operating Instructions. Before first use of the unit Please read these /07 KB 6060 Operating Instructions Before first use of the unit Please read these Operating Instructions and act in accordance with them 5.962-095.0 01/07 2 Dear Customer, Please read and comply with these

More information

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: 1-866-902-9690 8:00 am to 5:00 pm, C.S.T., Monday - Friday www.forcetoolsusa.com TABLE OF CONTENTS

More information

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION

Ultra Clean LAMBTON CONVEYOR LIMITED. Installation and Operation Manual ONE SOURCE ONE SOLUTION Ultra Clean Installation and Operation Manual LAMBTON CONVEYOR LIMITED ONE SOURCE 1 Contents Warranty... 4 Section 1. Safety... 5 Section 2. Decals... 8 Section 3. Product Information... 9 Ultra Clean

More information

APW PSI PRESSURE WASHER

APW PSI PRESSURE WASHER APW5001 1300 PSI PRESSURE WASHER 1300 PSI PRESSURE WASHER Please carefully read this manual which has been specifically designed to provide all the necessary information for the correct use of the machine,

More information

Owner & Operator s Manual. Table of Contents

Owner & Operator s Manual. Table of Contents Owner & Operator s Manual Model No. Voltage Frequency 908041/9495160 100-120V 50 60 Hz 9495161 230V 50 60 Hz Table of Contents DESCRIPTION PAGE Safety 2 Technical Data 2 Unpacking Instructions 3 General

More information

RX550i Electric Pressure Washer

RX550i Electric Pressure Washer RX550i Electric Pressure Washer READ THIS MANUAL CAREFULLY BEFORE USE FAILURE TO DO SO MAY RESULT IN INJURY, PROPERTY DAMAGE AND MAY VOID WARRANTY. KEEP THIS MANUAL FOR FUTURE REFERENCE. Products covered

More information

Installation & Operation Manual

Installation & Operation Manual Humidity & Temperature Sensor 086 Accessories 086_D 08/12 Replaces: New Installation & Operation Manual Introduction The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats

More information

Track Excavator OPERATOR S MANUAL

Track Excavator OPERATOR S MANUAL 1000183743 2.2 0309 Track Excavator 1404 OPERATOR S MANUAL 1 0 0 0 1 8 3 7 4 3 www.wackerneuson.com 1 1.1 Important operator information Special instructions Abbreviations / symbols Store the Operator

More information

HOT WASHER MODEL NO: KING150

HOT WASHER MODEL NO: KING150 WARNING: Do not use the hot washer without reading this manual HOT WASHER MODEL NO: KING150 PART NO: 7320175 OPERATION & MAINTENANCE INSTRUCTIONS LS1215 INTRODUCTION Thank you for purchasing this CLARKE

More information

Straight Suction Canister. Owner s Manual

Straight Suction Canister. Owner s Manual Straight Suction Canister Owner s Manual CONTENTS Getting Started Important Safety Instructions... 1 Polarization Instructions... 2 State of California Proposition 65 Warnings... 2 Description of the Vacuum...

More information

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0 Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL Manual v1.0 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE And neither are we. Always at the forefront of our industry, our

More information

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide Miniature Thermoelectric Cooler Controller MTCC-01 user's guide 1 Table of Contents 1. Warranty... 3 2. MTCC-01-xxx overview... 4 2.1. MTCC-01-xxx specification... 4 2.2. TE cooled detector temperature

More information

Models Series Series

Models Series Series Models 3180-Series 3181-Series INDUSTRIAL DIAPHRAGM PUMPS Commercial Duty, 3 GPM/1 LPM FEATURES Sealless Easy Installation Run Dry Ability Flow to 3 GPM/1 LPM Self-Priming Low Amp Draw Thermal Overload

More information

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer the best

More information

1600 Watt Professional

1600 Watt Professional FOR THE WAY YOU LIVE 1600 Watt Professional Steam Iron Model EP480 USE AND CARE INSTRUCTIONS Congratulations! You are the owner of the Shark 1600 Watt Professional Steam Iron. To fully enjoy the advantages

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285 Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL 2 BECAUSE YOU RE NOT LIKE EVERYONE ELSE. And neither are we. Always at the forefront of our industry, our goal is to offer the best

More information

SOOTHING COOL MIST AROMA DIFFUSER

SOOTHING COOL MIST AROMA DIFFUSER SOOTHING COOL MIST AROMA DIFFUSER FOR MODEL: EE-8003 If you have any questions about the operation of your aroma diffuser, please contact Crane Customer Care. Toll Free: 888-599-0992 Email: customer-service@crane-usa.com

More information

Electric Pressure Washer

Electric Pressure Washer Electric Pressure Washer S1700 039-8574-6 Owner s Manual If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664). PLEASE

More information

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

IMPORTANT INFORMATION - PLEASE READ CAREFULLY Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part

More information

CHILLER. Operator s & Installation Manual

CHILLER. Operator s & Installation Manual CHILLER MODEL: CFF-500 Operator s & Installation Manual Release Date: November 3, 1996 Publication Number: 90667 Revision Date: May 10, 2010 Revision: E Visit the IMI Cornelius web site at www.cornelius.com

More information

P/N CC-100. Coolant Circulator. Operation manual

P/N CC-100. Coolant Circulator. Operation manual P/N 4411-0019 CC-100 Coolant Circulator Operation manual Manual Version 1 Revision B July 1, 1998 Table of Contents Chapter 1 Introduction... 5 Description...5 Specifications...5 Chapter 2 Warnings...

More information

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

JASOPELS ROTATING FLESHING MACHINE 1-BEAM USER MANUAL JASOPELS ROTATING FLESHING MACHINE 1-BEAM ITEM NO. 32200067 Our quality Your choice 2 www.jasopels.com TABLE OF CONTENTS About this document... 3 Declaration of Conformity... 6 Safety... 6

More information

ERGO BACKPACK VACUUM OWNER S MANUAL

ERGO BACKPACK VACUUM OWNER S MANUAL ERGO BACKPACK VACUUM OWNER S MANUAL Model: VACBP1 120V 12A, 1400W ETL US Canada Atrix 1350 Larc Industrial Blvd. Burnsville, MN 55337 www.atrix.com sales@atrix.com Telephone: 952.894.6154 Toll Free Telephone:

More information

Topic Page # Assembly Instructions 6-8. Operating Instructions Detergents Clean-up and Storage Cleaning Tips 16.

Topic Page # Assembly Instructions 6-8. Operating Instructions Detergents Clean-up and Storage Cleaning Tips 16. Table Of Contents Topic Page # Important Safety Tips, Precautions, Warnings, and Usage Instructions 2-5 Assembly Instructions 6-8 Operating Instructions 9-12 Detergents 12-13 Clean-up and Storage 14-15

More information

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300 USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300 2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions...

More information

Super Super Super Works Super Super Works

Super Super Super Works Super Super Works Super 130.3 Super 135.3 Super 145.3 Works Super 150.3 Super 160.3 Works User Guide (07.2018) The instruction consists of 4 parts. Part 1:3 Safety Instructions. Part 2:3 User Guide. Part 3:3 Troubleshooting,

More information

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY BLACK CAT FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL:

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY BLACK CAT FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL: OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY MODEL : BLACK CAT FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL: SERIAL NUMBER: DATE PURCHASED: PURCHASED FROM: TABLE OF

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

SSS Intrepid 16 FMS. Manual

SSS Intrepid 16 FMS. Manual SSS Intrepid 16 FMS Manual The contents of this manual are based on the latest product information available at the time of publication. Triple S reserves the right to make changes or improvements to its

More information

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

IMPORTANT INFORMATION - PLEASE READ CAREFULLY Honeywell Garrett Direct Fit Performance Intercooler 2015+ 3.5L / 2.7L Ford F150 EcoBoost Bill of Materials and Precautions Application: 2015+ Ford F150 3.5L / 2.7L Eco Boost Part Number: 870702-6001 Part

More information

SSS BPV- 40 Backpack Vacuum

SSS BPV- 40 Backpack Vacuum SSS BPV- 40 Backpack Vacuum Manual The contents of this manual are based on the latest product information available at the time of publication. Triple S reserves the right to make changes or improvements

More information

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE INTRODUCTION OPERATING & MAINTENANCE INSTRUCTIONS This operator s book has important information for the use and safe operation of this machine.

More information

Read All Instructions Thoroughly Before Installing or Using the Disposer.

Read All Instructions Thoroughly Before Installing or Using the Disposer. SINK PRO NANOGRIND 3 BOLT PRO MOUNT OPERATING & INSTALLATION INSTRUCTION MANUAL BEFORE YOU BEGIN: NOTE: Your XO Food Waste Disposer has been designed exclusively for residential use, for operation on 120V

More information

Burgess. Electric Professional Fogger. CAUTION: Read and follow all instructions

Burgess. Electric Professional Fogger. CAUTION: Read and follow all instructions Burgess Electric Professional Fogger CAUTION: Read and follow all instructions Do Not Return This Fogger To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead Group, Inc.

More information

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials

Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials Efficient Vacuum Conveyors Deliver Cost-Effective Solutions Pick-up, conveying and feeding of powders, granules and other bulk materials VOLKMANN Inc. In the past, the flat price of a conveying system

More information

Owner s. 18 Misting MF18W. To view

Owner s. 18 Misting MF18W. To view Owner s Manual MF18W 18 Misting Fan IMPORTANT SAFETY INFORMATION: Please carefully read this manual before attempting to install or use this misting fan. For your safety, comply with all safety instructionss

More information

HDS-1000W Hot Dog Steamer

HDS-1000W Hot Dog Steamer HDS-1000W Hot Dog Steamer This manual contains important information regarding your Admiral Craft unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure

More information

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide FFP S700 SERIES Pull-Out Spray Faucet Installation guide G 1782 G 1748.XX G 29016 G 1156 G R0239.XX G 13396.XX G R0637 G R1664 G 1636 G 1463 TECHNICAL DATA Minimum working pressure 0,5 bar Maximum working

More information

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume K 2.75 High Pressure Washer Operator Manual Overview... 2 Precautions... 2-4 Assembly Instructions... 4 Operating Instructions... 5 Using the Accessories... 6 Working with Detergents... 7 Shut Down and

More information

Electric High-Pressure Washer - Operator s Manual

Electric High-Pressure Washer - Operator s Manual MC1800 English 1 Electric High-Pressure Washer - Operator s Manual Before operating this product, please read this manual thoroughly and retain it for future reference. 1-866-902-9690 www.mightycleanusa.com

More information

Operation Manual 322 KL

Operation Manual 322 KL Operation Manual 322 KL 8/07 von Oertzen GmbH Ferdinand-Harten-Str. 10 22949 Ammersbek Tel. +49 40 604110 Fax +49 40 6041149 www.oertzen-gmbh.de info@oertzen-gmbh.de Table of Content 1. Introduction Page

More information

InstructIon Manual KrEs EQuIPMEnt stands

InstructIon Manual KrEs EQuIPMEnt stands Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available

More information

TECCON. 2,5 to 10,0 t / H Water evaporation RATE

TECCON. 2,5 to 10,0 t / H Water evaporation RATE TECCON BELT DRYER 2,5 to 10,0 t / H Water evaporation RATE Installation of belt dryer 2 TECCON belt dryer Belt dryer 2,5 to 10,0 t / H Water evaporation RATE 1 Zentrales Element im Pelletswerk Norica ist

More information

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system. READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system. Attention Installer: Please be sure this manual and warranty information

More information

Electric Pressure Washer

Electric Pressure Washer Electric Pressure Washer S1900 039-8575-4 OWNER S MANUAL If you have any questions or comments, visit our website at www.simoniz.ca or call our toll free hotline 1-866-4SIMONIZ (1-866-474-6664) PLEASE

More information

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance

More information

TITAN FLOW CONTROL, INC.

TITAN FLOW CONTROL, INC. PREFACE: TITAN FLOW This manual contains information concerning the installation, operation, and maintenance of Titan Flow Control (Titan FCI) Suction Diffusers. To ensure efficient and safe operation

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

EXTRACTOR Operation & Maintenance Manual

EXTRACTOR Operation & Maintenance Manual EXTRACTOR Operation & Maintenance Manual 12 Gallon Carpet Extractor Models 2-100 2-100-H 3-100 3-100-H 2-200 2-200-H 3-200 3-200-H 2-500 2-500-H 3-500 3-500-H US & Foreign Patents Pending The design features

More information

INSTRUCTION MANUAL FOR MODEL SDT SOILED DISH TABLE (SCRAPPING TABLE)

INSTRUCTION MANUAL FOR MODEL SDT SOILED DISH TABLE (SCRAPPING TABLE) INSTRUCTION MANUAL FOR MODEL SDT SOILED DISH TABLE (SCRAPPING TABLE) Toll Free: 888-774-1616 Fax : (905)-363-6998 www.aero-werks.com - 1 - Aerowerks 2017 TABLE OF CONTENTS INSTRUCTION MANUAL FOR MODEL

More information

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER MODELS SF12-A PICTURED Page 1 of 12 Table of Contents Safety Precautions Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Systems

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information