1 VENTILATION FOR STUDENT ACCOMMODATION Featuring the NEW range

2 VENTILATION FOR STUDENT ACCOMMODATION NUAIRE UNDERSTANDS THE MANY CHALLENGES AND REGULATIONS THAT MODERN BUILDING VENTILATION MUST MEET AND OUR TECHNICAL TEAM ARE ON HAND TO ASSIST WITH PRODUCT SELECTIONS. DESIGN* & TECHNICAL ESTIMATING SUPPORT The correct system design is vital to ensure that ventilation products perform to their design intent. Our experienced team of technical design estimators are skilled at selecting the correct product and system layout to ensure that, once installed, the system will deliver the required airflow. Correct system layouts will ensure that the product is not noisy and inefficient. Nuaire s technical design estimators will provide clear guidance to ensure that installation is straight forward and in compliance with Part F Building Regulations *Nuaire require a full set of DWG s, Acoustic report & Fire Strategy. FAN SELECTOR Nuaire s Fan Selector is a practical and helpful tool to assist with the selection of ventilation products that, software provides detailed datasheets comprising of efficiency, performance, acoustics, wiring and specification. The software allows the data to be exported in Microsoft Excel or DWG format for AutoCAD. To download Fan Selector simply visit and follow the instructions. An reminder will be sent to you each time Fan Selector has been updated, enabling you to download the latest copy. REVIT COMPATIBLE BIM MODELS Nuaire has a dedicated BIM team offering libraries of Revit compatible BIM models to meet customers exact specifications. Nuaire s libraries offer collision detection, connection positions and weights. Project specific performance criteria and support for design, project management and building operations can be requested which will result in improved design efficiency. To download Nuaire s Revit compatible BIM models simply visit and click on the library. AFTERSALES SERVICE & SITE SUPPORT Nuaire prides itself on the quality of the design and manufacture of all its products. All products are tested prior to customer delivery. If customers do experience an issue on site, our team of highly knowledgeable Technical Support staff will provide expert advice and guidance on all of our products if an issue should arise. Our Technical Support staff are available to answer all product queries and if necessary provide an on-site support engineer. For further details on any of the above call Nuaire on

3 CONTENTS 2-3 TECHNICAL & DESIGN SUPPORT 4-5 UNI-X APPLICATION GUIDE 6-7 UNI-X FEATURES & BENEFITS 8-9 UNI-X SWITCH & SENSORS UNI-X220 PERFORMANCE & TECHNICAL DETAILS UNI-X360 PERFORMANCE & TECHNICAL DETAILS UNI-X580 PERFORMANCE & TECHNICAL DETAILS 16 UNI-X WIRING 17 UNI-X CONSULTANTS SPECIFICATION EXTRACT & HEAT RECOVERY PRODUCT SELECTOR 20 Q-AIRE CARBON FILTRATION Q-AIRE SUPPLY & EXTRACT VALVES Q-AIRE IAQBOX-S Q-AIRE IAQBOX-D 27 Q-AIRE IAQBOX CONSULTANTS SPECIFICATION 28 DUCTMASTER DUCTING & ANCILLARIES DUCTMASTER THERMAL DUCTING & ANCILLARIES DUCTMASTER - TYPICAL DUCTING ARRANGEMENTS DUCTMASTER PVC DUCTING & ANCILLARIES DUCTMASTER RADIAL DUCTING & ANCILLARIES nuaire.co.uk 3

4 APPLICATION GUIDELINES WITH THE INCREASE IN STUDENT NUMBERS COMES THE NEED FOR STUDENT ACCOMMODATION COVERING ALL TYPES OF PROPERTIES FROM SPECIFICALLY DESIGNED STUDENT BLOCKS THROUGH TO INDIVIDUAL REFURBISHED HOUSES. Student accommodation can feature many configurations including communal lounges and kitchens, individual bedroom/study areas through to 12 bed clusters. Nuaire appreciates that Student accommodation often requires unique solutions. With this in mind, Nuaire has developed a wide range of ventilation products to ensure the highest level of indoor air quality with the lowest level of occupier interaction. MECHANICAL EXTRACT WITH HEAT RECOVERY FOR LIVING AND COMMUNAL AREAS: (UNI-X, XBC & MRXBOXAB-ECO-LP1). Heat recovery systems offer efficiency and control over the air quality and volume within the accommodation. Providing tempered air into living areas whilst extracting moisture laden air from wet areas. Heat recovery is ideal for student and other multi-storey accommodation. MECHANICAL EXTRACT FOR BATHROOMS, TOILETS AND KITCHENS: (GENIE, XS, AIREVOLVE AVS, AVT, MEVDC, OPUS & DAVE). Nuaire offers a wide range of extract fans for wall, window, roof and ceiling/void applications. Fans can be located in wet rooms, kitchens, utility areas and roof, extracting from wet areas and kitchens whilst providing continuous fresh air via trickle ventilators. TYPICAL LAYOUTS UNI-X360. Up to 8 cluster (plus kitchen/communal living space). CONSTANT PRESSURE FOR MULTI-ROOM VENTILATION: (AVT-CP, AVS-CP, XBC & BOXER BPS). Why ventilate empty rooms? Constant pressure is ideal for student accommodation. A central extract system provides all the necessary extraction, via a central fan, which is normally positioned on a roof and unique multiposition CVD dampers or NRG grilles which ensure operation only when room is occupied

5 UNI-X580. Up to 12 cluster (plus kitchen/communal living space). UNI-X220. Up to 4 cluster (plus kitchen/communal living space). nuaire.co.uk 5

6 MECHANICAL VENTILATION WITH HEAT RECOVERY UNI-X is a range of high performance heat recovery units offering efficiency and control over the air quality and volume within the accommodation. The units provide tempered air into the living areas whilst extracting stale moisture-laden air from wet areas. n INSTALLATION TEMPLATE - A mounting template is provided with every UNI-X unit. UNI-X Range is ideal for Student accommodation and other applications such as meeting rooms and offices. n HIGH EFFICIENCY HEAT EXCHANGER - Counter flow heat exchanger with efficiencies up to 90% (Eurovent Certified) n LOW SPECIFIC FAN POWER - High efficiency ErP 2018 EC blowers with IP54 rating and stepless speed control n CLASS LEADING NOISE LEVELS - Unique casing design with internal profiling and external acoustic cladding ensures lower noise levels n AUTOMATIC 100% BYPASS FACILITY - Guarantees the delivery of fresh, clean air in the summer months, activated +20 degrees C n SPACE SAVING - Low profile unit designed for ceiling voids. All units have a maximum depth of 295mm n EASY TO MAINTAIN - G3 filters fitted as standard to both supply & extract air paths and can be accessed from underside of unit. Carbon filter options are available, see page 20 n QUICK TO INSTALL - An adhesive positioning template is supplied with every unit to ensure a quick installation n PEACE OF MIND - UNI-X range has a 2 year warranty n SIMPLE CONTROL - In-built control, factory tested to provide trickle/boost facility. Choice of boost switches available n STACKED IN MULTIPLES OF 3 - Units are delivered shrink wrapped in multiples of 3 to ease manoeuvrability on site

7 n INTEGRAL MOUNTING BRACKET AS STANDARD - Helps reduce installation time. n CLASS LEADING NOISE LEVELS - Unique rigid casing design with acoustic cladding. n G3 FILTERS AS STANDARD - Can be easily accessed from underside of unit via two moulded filter retainers. UNI-X580 Up to 12 cluster (plus kitchen/ communal living space). UNI-X360 Up to 8 cluster (plus kitchen/ communal living space). UNI-X220 Up to 4 cluster (plus kitchen/ communal living space). n UNITS ARE NOT HANDED - The condensate pipe is positioned at the front of the unit. Condensate pump ancillary available contact Nuaire. n UNI-X SPIGOTS - UNI-X units are available with either rectangular spigots (220 x 90mm) (Code example UNI-X220) or circular spigots ( Ø150mm) (Code example UNI-X220-C) as standard. MVHR-DRAIN is available as an ancillary (see page 45 for details). nuaire.co.uk 7

8 UNI-X STANDARD CONTROL SWITCH & SENSORS n UNI-X STANDARD CONTROL n UNI-X 3 SPEED SWITCH For simple control and commissioning we offer a 3 speed switch. (Code: MRXBOX95-3SWITCH) DIMENSIONS (mm) Front view Side view Flush mounting face to wall or back box The UNI-X control is pre-wired, factory fitted, factory tested and incorporates the following functionality: Integrally mounted within the fan unit on purpose-made PCB Independent control of 3 supply and extract flow rates. Controls can be used to set trickle, boost and maximum flow rates Integral fan failure indication Integral S/L terminal for maximum set speed, from remote switch e.g. plate switch Integral S/L terminal for boost set speed, from remote switch, e.g. light switch Integral heat exchanger frost protection Discrete daily run monitor n ES-PIR2 (Enabler) Detects movement and activates system. Incorporates a system status LED, overrun timer and timer adjustment. (Code: ES-PIR2) DIMENSIONS (mm) Plan view Side view n ES-JB JUNCTION BOX Compatible with Ecosmart System this unit is supplied with a pre-plugged 10 metre length of communications cable DIMENSIONS (mm) and has 8 further ports. (Code: ES-JB) (Maximum of two ES-JB s per UNI-X unit which provides 16 available ports for sensors) mm 86mm dia. 150 TYPICAL LAYOUTS - with suggested switch, sensors & lighting circuit 6 bed cluster (plus kitchen/communal living space). COLOUR KEY: SWITCH & SENSORS & LIGHTING CIRCUIT UNI-X 3 SPEED SWITCH BOOST SWITCHES ES-PIR2 ES-AVI2 ES-HUMIDISTAT2 LIGHTING CIRCUIT

9 UNI-X STANDARD CONTROL SWITCH & SENSORS n PIR SENSOR WITH RUN-ON TIMER Passive Infra Red (P.I.R) movement detector. (Code: 230-PIR) DIMENSIONS (mm) 16mm n BOOST SWITCHES To boost from LOW to HIGH speed. Boost switches settable between 2 minutes and 120 mins (2 hrs). Illuminated push button run-on timer switch. (Code: UNI-X-BT). Illuminated touch sensor button run-on timer switch. (Code: UNI-X-TT) DIMENSIONS (mm) 10mm dep 86mm 85mm 86mm 85mm n ES-AVI2 (Enabler) When fan failure occurs the AVI will flash a warning. Supplied with pre-plugged 10m length of communication cable. (Code: ES-AV12) DIMENSIONS (mm) Plan view Side view 25.50mm 86mm dia. n ES-HUMIDISTAT2 (Enabler) Activates the system when the RH level is above set point. Incorporates two system status LEDs. (Green = OK, Red = Failure) and RH set point level adjustment. (Code: ES-HUMIDISTAT2) DIMENSIONS (mm) Plan view Side view 25.50mm 86mm dia. n ES-VF Signal conditioning circuit for humidity, temperature and CO 2 sensors. (Code: ES-VF) DIMENSIONS (mm) Plan view End view 7 X 25mm dia. cable entry grommets 110 n Q-AIRE FILTERED INLET/EXTRACT AIR VALVES (Ø 125mm ) Adjustable, lockable with no adjustment after a filter change. (Codes: Q-AIRE-EV125, EV125F & EV125FH) DIMENSIONS (mm) dia. 125 dia (Optional filter fitted) closed 38.0 open (max) 10 bed cluster (plus kitchen/communal living space). 4 bed cluster (plus kitchen/communal living space). nuaire.co.uk 9

10 UNI-X220 PERFORMANCE & TECHNICAL DETAILS UNI-X220 RECTANGULAR SPIGOTS UNIT PERFORMANCE % Speed ISO AMCA 300 V Type D Air Density 1.2 kg/m Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X220 RECTANGULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X220 Open Extract 100% (Maximum Open Supply 100% Rectangular) Breakout 100% UNI-X220 EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 2 Bed 1 29 l/s 75 Pa Bed 1 37 l/s 75 Pa Bed 1 45 l/s 75 Pa UNI-X220 TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X x 572 x 1003 UNI-X220 RECTANGULAR SPIGOTS (220 x 90mm) UNIT DIMENSIONS 977 View on A 152 A B C Filter Access Control Access 75 C/L 285 View on B 142 EXTRACT FROM ROOM INTAKE FROM OUTSIDE SUPPLY TO ROOM EXHAUST TO OUTSIDE Condensate Pipe 132 C/L 285 Control Access View on C

11 UNI-X220-C PERFORMANCE & TECHNICAL DETAILS UNI-X220-C CIRCULAR SPIGOTS UNIT PERFORMANCE % Speed ISO AMCA 300 V Type D Air Density 1.2 kg/m Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X220-C CIRCULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X220-C Open Extract 100% (Maximum Open Supply 100% Circular) Breakout 100% UNI-X220-C EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 2 Bed 1 29 l/s 75 Pa Bed 1 37 l/s 75 Pa Bed 1 45 l/s 75 Pa UNI-X220-C TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X220-C x 572 x 1003 UNI-X220-C CIRCULAR SPIGOTS (150mm dia.) UNIT DIMENSIONS 1000 View on A 160 A B C Filter Access Control Access 93 C/L 285 View on B 85 EXTRACT FROM ROOM INTAKE FROM OUTSIDE SUPPLY TO ROOM EXHAUST TO OUTSIDE Condensate Pipe 134 C/L 285 Control Access View on C nuaire.co.uk 11

12 UNI-X360 PERFORMANCE & TECHNICAL DETAILS UNI-X360 RECTANGULAR SPIGOTS UNIT PERFORMANCE ISO AMCA 300 V Type D Air Density 1.2 kg/m % Speed 300 Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X360 RECTANGULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X360 Open Extract 100% (Maximum Open Supply 100% Rectangular) Breakout 100% UNI-X360 EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 5 Bed 1 53 l/s 75 Pa Bed 1 61 l/s 75 Pa Bed 1 69 l/s 75 Pa Bed 1 77 l/s 75 Pa UNI-X360 TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X x 721 x 1095 UNI-X360 RECTANGULAR SPIGOTS (220 x 90mm) UNIT DIMENSIONS 1072 A B View on A 194 C Filter Access Filter Access 160 C/L 361 EXTRACT FROM ROOM INTAKE FROM OUTSIDE View on B 130 SUPPLY TO ROOM EXHAUST TO OUTSIDE 21mm Dia. Condensate Pipe (PVC) 163 C/L 361 Control Access View on C Control Access

13 UNI-X360-C PERFORMANCE & TECHNICAL DETAILS UNI-X360-C CIRCULAR SPIGOTS UNIT PERFORMANCE ISO AMCA 300 V Type D Air Density 1.2 kg/m % Speed Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X360-C CIRCULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X360-C Open Extract 100% (Maximum Open Supply 100% Circular) Breakout 100% UNI-X360-C EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 5 Bed 1 53 l/s 75 Pa Bed 1 61 l/s 75 Pa Bed 1 69 l/s 75 Pa Bed 1 77 l/s 75 Pa UNI-X360-C TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X360-C x 721 x 1095 UNI-X360-C CIRCULAR SPIGOTS (150mm dia.) UNIT DIMENSIONS 1095 View on A A B 180 C Filter Access Filter Access 188 C/L View on B 361 EXTRACT FROM ROOM INTAKE FROM OUTSIDE 92 SUPPLY TO ROOM EXHAUST TO OUTSIDE 21mm Dia. Condensate Pipe (PVC) 128 C/L Control Access View on C nuaire.co.uk 13

14 UNI-X580 PERFORMANCE & TECHNICAL DETAILS UNI-X580 RECTANGULAR SPIGOTS UNIT PERFORMANCE ISO AMCA 300 V Type D Air Density 1.2 kg/m % Speed Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X580 RECTANGULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X580 Open Extract 100% (Maximum Open Supply 100% Rectangular) Breakout 100% UNI-X580 EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 9 Bed 1 85 l/s 75 Pa Bed l/s 100 Pa Bed l/s 100 Pa UNI-X580 TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X x 988 x 1156 UNI-X580 RECTANGULAR SPIGOTS (220 x 90mm) UNIT DIMENSIONS A B C View on A 268 C/L Filter Access Filter Access EXTRACT FROM ROOM INTAKE FROM OUTSIDE C/L View on B 103 SUPPLY TO ROOM EXHAUST TO OUTSIDE 21mm Dia. Condensate Pipe (PVC) Control Access View on C Control Access C/L

15 UNI-X580-C PERFORMANCE & TECHNICAL DETAILS UNI-X580-C CIRCULAR SPIGOTS UNIT PERFORMANCE ISO AMCA 300 V Type D Air Density 1.2 kg/m % Speed Static Pressure (Pa) SFP 2.0 W/(l/s) Airflow (l/s) UNI-X580-C CIRCULAR SPIGOTS UNIT - ACOUSTIC DATA Volume Fan Static Sound Power Levels re 1pW (Hz) Fan Code Type Speed Flow (l/s) Pressure (Pa) k 2k 4k 8k (dba@3m) UNI-X580-C Open Extract 100% (Maximum Open Supply 100% Circular) Breakout 100% UNI-X580-C EXAMPLE SELECTIONS - For further details please refer to Nuaire Fan Selector ( No. of beds Plus kitchen/living Duty PA SFP dba 9 Bed 1 85 l/s 75 Pa Bed l/s 75 Pa Bed l/s 75 Pa UNI-X580-C TECHNICAL DATA Voltage Input power FLC/SC Fan Speed Unit Weight Pallet/Crate Dimensions (Stack of 3) Fan Code (V AC) (kw) (A) (RPM) (kg) H x W x L (mm) UNI-X580-C x 988 x 1156 UNI-X580-C CIRCULAR SPIGOTS (150mm dia.) UNIT DIMENSIONS 1136 A B View on A 274 Filter Access C Filter Access EXTRACT FROM ROOM INTAKE FROM OUTSIDE C/L View on B 53 EXHAUST TO OUTSIDE SUPPLY TO ROOM 21mm Dia. Condensate Pipe (PVC) Control Access 203 C/L 493 View on C Control Access nuaire.co.uk 15

16 UNIT SERVING KITCHEN AND BATHROOM UNI-X MECHANICAL VENTILATION WIRING Disconnection from the supply mains must be incorporated within the fixed wiring in accordance with the wiring regulations and shall have a minimum contact separation of 3mm. MAINS 230V 50Hz N L Fuse 3A Light switch (Double Pole) Room light 3 Pole isolator Green/yellow Blue Brown Black Grey Optional boost switch Supply cord from unit Kitchen switch / 230PIR UNIT SERVING KITCHEN AND TWO BATHROOMS Disconnection from the supply mains must be incorporated within the fixed wiring in accordance with the wiring regulations and shall have a minimum contact separation of 3mm. MAINS 230V 50Hz N L Fuse 3A Light switches (Double Pole) Room lights 3 Pole isolator Green/yellow Blue Brown Black Grey Optional boost switch Supply cord from unit Kitchen switch / 230PIR

17 UNI-X MECHANICAL VENTILATION CONSULTANTS SPECIFICATION UNIT SPECIFICATION The unit shall be manufactured from high density EPS (Expanded polystyrene) with galvanised sheet steel casing to provide excellent thermal and acoustic characteristics, while providing a lightweight and low profile casing. Incorporating a high efficiency, aluminium counter flow heat exchanger block with a thermal efficiency of up to 90%. The heat exchanger will be protected by two G3 grade filters in the fresh inlet and system extract air streams, with both filters being accessible from the underside of the unit allowing for quick and easy maintenance. The unit shall have a maximum height less than 295mm to fit within ceiling voids. The unit will contain two, low energy, high efficiency EC fan assemblies, with centrifugal backward curved impellers offering IP54 rating and stepless speed control. The fans will have the facility for variable speed control at trickle (continuous background ventilation), and boost speed to allow for individual specific adjustment during commissioning. The motors shall be suitable for use in ambient temperatures of 40 C. CONTROL OPTIONS The control shall be capable of 3 speed operation. All versions shall have the following functions integrally mounted with the fan unit on a purpose made PCB, all such components are pre-wired and factory fitted by the manufacturer: Independent control of background supply and extract flow rates Independent control of boost speed supply and extract flow rates Independent control of secondary boost speed supply and extract flow rates Integral fan failure indication OPERATION The unit shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. The combined supply and heat recovery unit shall supply filtered fresh air to each to the habitable rooms whilst extracting moisture-laden air from wet area s e.g Bathrooms. The supply air shall be tempered via the counterflow heat exchanger. The unit shall boost its speed and therefore the ventilation rate as it receives a signal from light/remote switch. The unit shall have a secondary boost speed in addition to the standard boost speed. The unit shall have the facility to commission the supply and extract fan independently at all 3 speeds. UNITS WITH RECTANGULAR SPIGOTS UNI-X220: The unit shall be suitable for 220 x 90mm Rectangular ducting. UNI-X360: The unit shall be suitable for 220 x 90mm Rectangular ducting. UNI-X580: The unit shall be suitable for 220 x 90mm Rectangular ducting. UNITS WITH CIRCULAR SPIGOTS UNI-X220-C: The unit shall be suitable for Ø150mm Circular ducting. UNI-X360-C: The unit shall be suitable for Ø150mm Circular ducting. UNI-X580-C: The unit shall be suitable for Ø150mm Circular ducting. Integral Switch Live terminal for boost speed commission level, from remote switch e.g light switch Integral Switch Live terminal for secondary boost to commission level from remote switch, e.g wall switch Integral heat exchanger frost protection. Automatic summer bypass The unit shall be supplied complete with a condensate drip tray and 21.5mm drain connection. The unit shall be fitted as standard with an automatic 100% bypass facility. The bypass opens automatically when the supply air exceeds 20 C, this opens the bypass channel via actuators and allow the outside air to bypass the heat exchanger. The air which is bypassed will still pass through the filter to ensure that the air quality remains the same regardless of the external temperatures. CODE DESCRIPTION UNI-X360-C UNI-X = Range = Unit model 220, 360 or C = Circular spigots, No C = Rectangular spigots The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. nuaire.co.uk 17

18 EXTRACT RANGE PRODUCT SELECTOR LOCAL UNITS CENTRALISED UNITS LOCAL & CENTRALISED UNITS WALL & CEILING MOUNTED GENIE DC Duty Up to 31l/s Single Room with ensuite Bedsit with kitchen 1, 2 and 3 bed apartment Single Room ensuite centralised Bedsit with kitchen centralised 1, 2 and 3 bed apartment centralised Cluster (up to 4) plus kitchen/ living space Cluster of (up to 8) plus kitchen/ living space Cluster (up to 12) plus kitchen/ living space GENIE DCE Up to 31l/s DMEV Up to 18l/s XS6, 9 & 12 Up to 530l/s OPUS 40, 60 & 95 Up to 95l/s DUCTED IN CEILING VOIDS ES-OPUS DC Up to 110l/s MEVDC Up to 98l/s MEVDC2 Up to 98l/s DAVE Up to 1.1m 3 /s AIRVOLVE AVS/CP (Single fan) Up to 1.8m 3 /s AIRVOLVE AVT/CP (Twin fan) Up to 1.8m 3 /s QUIETSCROLL EST/CP (Twin fan) Up to 4.5m 3 /s PLANT ROOMS INTERNAL/ROOF TOP/EXTERNAL DAVE Int/Ext Up to 1.1m 3 /s AIRVOLVE AVS/CP (Single fan) Internal only Up to 1.8m 3 /s AIRVOLVE AVT/CP (Twin fan) Int/Ext Up to 1.8m 3 /s QUIETSCROLL EST/CP (Twin fan) Int/Ext Up to 4.5m 3 /s

19 HEAT RECOVERY PRODUCT SELECTOR LOCAL UNITS CENTRALISED UNITS LOCAL & CENTRALISED UNITS WALL & CEILING MOUNTED Duty Single Room with ensuite Bedsit with kitchen 1, 2 and 3 bed apartment Single Room ensuite centralised Bedsit with kitchen centralised 1, 2 and 3 bed apartment centralised Cluster (up to 4) plus kitchen/ living space Cluster of (up to 8) plus kitchen/ living space Cluster (up to 10) plus kitchen/ living space MRXBOX95AB-WM1 Up to 52.1l/s MRXBOX95AB-WM2 Up to 90l/s MRXBOX95AB-WH1 Up to 110l/s MRXBOX95AB-WH2 Up to 180l/s DUCTED IN CEILING VOIDS MRXBOX95AB-ECO-LP1 Up to 78l/s OPUS-XBOX Up to 100l/s XBC Up to 0.79m 3 /s XBC 10-65/CP Up to 0.79m 3 /s PLANT ROOMS/ROOF TOP/EXTERNAL XBC10-85/WP Up to 2.1m 3 /s XBC10-85/WP/CP Up to 2.1m 3 /s BOXER PACKAGED SOLUTIONS Up to 5m 3 /s BOXER BESPOKE Up to 10m 3 /s l l l l nuaire.co.uk 19

20 CARBON FILTRATION The Nuaire Q-Aire range of products has been designed to complement ventilation systems that are a necessity in modern living. We recognise that customers need products quickly, systems that work quietly and confidence in their high quality - something that comes as standard with Nuaire. The range is comprised of a supply and extract valve, an in-line carbon filter, an acoustic enclosure for an MVHR unit only and finally a unique all-in-one acoustic enclosure surrounding not only an MVHR unit but a built in silencer as well. Q-AIRE-V125, EV-125F & EV-125FH The supply & extract Valve can help solve common problems with MVHR commissioning, balancing and performance. It is available in three versions: 1. Standard supply and extract (Q-Aire-V125) 2. Filtered extract (Q-Aire-EV125F) 3. Filtered extract with integral humidistat (Q-Aire-EV125FH). Q-Aire supply & extract valve is the only lockable, filtered valve on the market and is fully-compliant with the latest NHBC guidance. Q-AIRE IAQBOX-S Nuaire s IAQBOX range offers solutions for urban areas where air pollutants such as NO2, Carbon Dioxide and dangerous Particulate Matter need to be filtered before outdoor air enters the property. These specifiable products will refine traditional filtration and ensure that Air Quality planning obligations are met. The IAQBOX-S offers a unique approach in carbon filtration by using a single cell carbon filter to refine polluted outdoor air that MVHR systems bring in to properties. Q-AIRE IAQBOX-D The IAQBOX-D is Nuaire s unique offering, showcasing a double size unit which allows a larger volume of air-flow to pass through the carbon filter resulting in some of the lowest resistances on the market. This unit also comes with the option of 2 outlet spigots, further reducing system pressure and resistance by decreasing the number of duct runs needed to feed to all supply rooms. Q-AIRE-EV125F Extract valve with filter. Typical IAQBOX-S installation. Typical IAQBOX-D installation

21 CARBON FILTRATION Q-AIRE V125, EV125F & EV125FH As Mechanical Ventilation Heat Recovery fast becomes the most popular form of ventilation, Nuaire continue to lead the way in innovation and design. The Q-AIRE supply & extract valve can help solve common problems with MVHR commissioning, balancing and performance. Q-AIRE BENEFITS EVERYBODY FROM CONSULTANTS TO INSTALLERS n STANDARD SUPPLY AND EXTRACT (Q-AIRE-V125) Q-Aire supply & extract valve is the only lockable, filtered valve on the market and is fully-compliant with the latest NHBC guidance n FILTERED EXTRACT (Q-AIRE-EV125F) The filtered extract version removes the need for a duct cleaning regime and access panels because air is filtered before it enters the ducting. The valve is lockable once commissioned and even when the filter is removed and changed. Once replaced, it returns to the commissioned position n FILTERED EXTRACT WITH INTEGRAL HUMIDISTAT (Q-AIRE-EV125FH) Q-Aire extract valve is the only lockable, filtered valve on the market and is fullycompliant with the latest NHBC guidance. The in-built humidity sensor simply uses the Ecosmart SELV cable to connect back to the MVHR or MEV unit COMING SOON! The IAQ-V125 is Nuaire s unique carbon filter supply valve. Q-AIRE-V125 Supply and extract valve. Q-AIRE-EV125F Extract valve with filter. Q-AIRE-EV125FH Extract valve with filter and fitted integral humidistat. Q-AIRE valve shown installed. The filter can be quickly replaced by simply removing the damper assembly and changing the filter. The damper assembly is then put back into its place without any adjustment of the commissioned set point, thus ensuring the system remains commissioned. nuaire.co.uk 21

22 CARBON FILTRATION AIR RESISTANCE PERFORMANCE Resistance @37l/s Existing V125S - 10mm Gap (CATALOGUE VALUES) Q-AIRE-V125 (13mm Gap - Extract) Q-AIRE-V125 (13mm Gap - Supply) Q-AIRE-EV125F (13mm Gap - Extract) Q-AIRE-EV125FH (13mm Gap - Extract) Q-AIRE SUPPLY & EXTRACT VALVES CONSULTANTS SPECIFICATION OPERATION The supply and extract valves are used to control and distribute airflow entering or being removed from a dwelling. They shall be capable of being used on their own, with a filter or with a filter and integral humidistat control. UNIT SPECIFICATION Each valve shall be low profile, protruding from the ceiling by no more than 18mm when closed. Each valve will be suitable for 125mm diameter ducting. Each valve shall be made from flame retardant ABS plastic. There shall be a means of adjusting the opening aperture for commissioning purpose with a decorative panel supplied to hide the commissioning screw. The flow deflector shall be spring-loaded to prevent vibration. It shall be possible to remove/replace the bezel disc assembly within the bezel for filter access without altering the commissioned position of the valve or deflector. An optional humidity PCB for connection to ventilation unit shall be available with set point disc removal. Humidistat PCB shall be Nuaire Ecosmart compatible. The valve shall be offered with a 5 year warranty. The manufacturer s recommendations should be observed at all times. The valve shall be manufactured by Nuaire. OPTIONS Three options shall be available: Q-AIRE-V-125 Supply & Extract Valve Q-AIRE-EV125F Extract Valve with filter Q-AIRE-EV125FH Extract Valve with filter and fitted with integral humidistat. The filter shall be easily removed and be of G2 grade. The assembly shall be supplied with a deflector plate to enable air to be directed away from obstacles or to prevent air being blown in a direction which would create nuisance draughts

23 IAQBOX-S CARBON FILTRATION Q-AIRE IAQBOX-S The IAQBOX-S offers a unique approach in carbon filtration by using a single cell carbon filter to refine polluted outdoor air that MVHR systems bring in to properties. n 99.5% NO2 FILTRATION - highest on the market n LOWEST RESISTANCE - meaning MVHR systems are not affected n CARBON FILTER - unique single cell n CHOICE OF PRE-FILTERS - for increased Particulate Matter filtration n LOW PROFILE DESIGN - for flexible installation AIR RESISTANCE TEST Resistance (Pa) IAQBOX-S with PM2.5 pre-filter IAQBOX-S with PM10 pre-filter only IAQBOX-S with Carbon Filter only Flow rate (l/s) There is a choice of PM2.5 or PM10 pre-filters to further enhance the filtration of polluted, outdoor air when it enters the property. To specify the IAQBOX-S with fitted pre-filters please choose from the following codes. PM2.5 OR PM10 PRE-FILTERS IAQBOX-S IAQBOX-S- IAQBOX-S- PM10 PM2.5 No Pre-filter PM10 Pre-filter PM2.5 Pre-filter nuaire.co.uk 23

24 IAQBOX-S DIMENSIONS (mm) IAQBOX-S DIMENSIONS (mm) TOP VIEW END VIEW SIDE VIEW TYPICAL EXAMPLE OF A UNI-X580 MVHR UNIT WITH IAQBOX-S, INSTALLED IN THE SUPPLY DUCTING. Top of ceiling void. Exhaust air from kitchen/bathroom to outside via air brick. Insulated extract duct. Air supply to lounge via Air Valve in ceilings. Minimum distance as specified in building regulations. Intake air from outside via air brick.. Extract air from kitchen via Air Valve in ceilings. Air supply to bedrooms via Air Valve in ceilings. Extract air from bathroom via Air Valve in ceilings. All duct between MVHR unit and atmosphere to be insulated. Insulated supply duct. Nuaire UNI-X580 MVHR unit. IAQBOX-S Inline Carbon Filter unit installed into the supply ducting

25 IAQBOX-D CARBON FILTRATION Q-AIRE IAQBOX-D The IAQBOX-D is Nuaire s unique offering, showcasing a double size unit which allows a larger volume of air-flow to pass through the carbon filter resulting in some of the lowest resistances on the market. This unit also comes with the option of 2 outlet spigots, further reducing system pressure and resistance by decreasing the number of duct runs needed to feed to all supply rooms. n 99.5% NO2 FILTRATION - highest on the market n LOWEST RESISTANCE - meaning MVHR systems are not affected n LOW PROFILE DESIGN - for flexible installation n TWO OUTLET SPIGOT - option n CARBON FILTER - unique single cell n INNOVATIVE DOUBLE SIZE UNIT - with multispigot option n CHOICE OF PRE-FILTERS - for increased Particulate Matter filtration AIR RESISTANCE TEST Resistance (Pa) IAQBOX-D with PM2.5 pre-filter IAQBOX-D with PM10 pre-filter only IAQBOX-D with Carbon Filter only Flow rate (l/s) There is a choice of PM2.5 or PM10 pre-filters to further enhance the filtration of polluted, outdoor air when it enters the property. To specify the IAQBOX-D with fitted pre-filters please choose from the following codes. PM2.5 OR PM10 PRE-FILTERS IAQBOX-D IAQBOX-D- IAQBOX-D- PM10 PM2.5 No Pre-filter PM10 Pre-filter PM2.5 Pre-filter nuaire.co.uk 25

26 IAQBOX-D DIMENSIONS (mm) IAQBOX-D DIMENSIONS (mm) TOP VIEW END VIEW (OUTLET) SIDE VIEW TYPICAL EXAMPLE OF A IAQBOX-D UNIT INSTALLED IN THE SUPPLY DUCTING. Units are supplied complete with a mounting bracket for quick and easy surface mounted installation. Access to the unit for maintenance is granted via the bottom panel. Ensure that an access panel has been allowed for maintenance to the unit

27 IAQBOX-S & IAQBOX-D CONSULTANTS SPECIFICATION UNIT SPECIFICATION The IAQBOX-S and IAQBOX-D (plus pre-filter variant codes) comprise the Q-Aire IAQBOX range and shall be manufactured in galvanised sheet metal, with an integral foam lining to reduce noise & provide internal sealing. Each inline filter shall have the ability to have an optional PM10 or PM2.5 pre-filter inserted into the filter box to be capable of additional particulate filtration; particularly from diesel vehicle fumes. The IAQBOX shall come complete with a removable mounting bracket. The double size IAQBOX-D range of units have the option to be configured using a single or double spigot on the outlet. The unit shall be suitable for 220 x 90mm ducting. The unit shall be installed in conjunction with the manufacturer s installation and maintenance guidelines. The unit shall be offered with a 5 year warranty; 1 year parts and labour, remaining years parts only. This warranty is void if the equipment is modified without authorisation, is incorrectly applied, misused, disassembled or not installed, commissioned and maintained in accordance with the details contained in the I&M manual and general good practice. Double spigot on the outlet shall provide lower air resistance and further ducting options. The IAQBOX shall come complete with a single carbon cartridge of plastic construction, containing two 30mm (approx.) beds of activated carbon pellets providing a large surface to filter the airflow. The filters shall be easily removed and replaced when required. The filter shall have a minimum efficiency of between 96% and 99.5% effectiveness in the removal of Nitrogen Oxides/Dioxides. The unit efficiency shall be confirmed and independently verified by a BRE (Building Research Establishment) test method and the information shall be provided by the filter manufacturer for approval. The activated carbon shall have at least the following minimum qualities: BULK DENSITY KG/M (+/-5% Nominal diameter of cylindrical pellets mm 4.0 Nominal length of cylindrical pellets mm 8.0 Moisture content (approx.) % 3 Crush strength (minimum) kg 2 Removal capacity for CI2 of own weight % 10 Minimum design efficiency % 99.5 Typical air velocity m/s Suitable for relative air humidities % Temperature range o C nuaire.co.uk 27

28 DUCTING & ANCILLARIES Ductmaster is a fully comprehensive range of installation ancillaries for all ducted applications, to ensure you achieve the most cost effective solution. Installation is quick and easy, significantly reducing both costs and time spent on site. The range includes Ductmaster Thermal, Ductmaster PVC and Ductmaster Radial. DUCTMASTER THERMAL DUCTMASTER PVC DUCTMASTER RADIAL Nuaire s award-winning Ductmaster Thermal range is a quick and effective solution for ducting in unheated spaces. Unlike other thermal ducting systems that fit around the PVC pipe, Nuaire s Ductmaster is an all-in-one complete insulated ducting system, providing a cost effective and quick installation. A comprehensive range of PVC ducting and ancillaries for the domestic market, Ductmaster PVC is available as a circular duct, a slim duct which is ideal for apartments or ceiling voids, or a flat duct for where space is at a premium. Nuaire Ductmaster Radial (NRD75) is a range of semi-rigid ducting and ancillaries, intended for installation in domestic properties. Unlike other types of ducting systems, Nuaire s Radial Ducting design negates the need for multiple lengths of duct, bends and ancillaries, minimising duct leakage and reducing installation time. Ductmaster Radial works perfectly with the Ductmaster Thermal ducting. n Use rigid duct for the majority of your installation n Avoid using flexible ducting, if you must, remember the regulations, pull taut to 90% of its length, support the install and don t install where it can be crushed n Minimise bends and ensure your duct routes take the path of least resistance n Use insulated ducting for unheated spaces or heated spaces that are carrying cold air n Install Nuaire s CONTRAP and install the ductwork correctly to prevent backflow of moisture going to the fan unit n Follow the design provided by Nuaire

29 THERMAL DUCTING & ANCILLARIES DUCTMASTER THERMAL The award-winning, all-in-one Thermal Ducting solution that fully complies with building regulations. The lightweight material means that installation becomes a one-man job, while the unique clip system forms an airtight seal, with no need for sealant or tape. THE ONLY COMPLETE SOLUTION ON THE MARKET n FULLY COMPLIANT with Building Regulations n IMPROVED thermal efficiency n UNIQUE CLAMPING MECHANISM no requirement for sealant and tape n LIGHTWEIGHT MATERIAL - one person install n SIMPLE QUICK-FIT COMPONENTS n SIGNIFICANTLY REDUCES time on site n ENVIRONMENTALLY FRIENDLY - through eco-efficiency n COST-EFFECTIVE SOLUTION n INDEPENDENTLY TESTED for thermal conductivity by BASF Germany n LABC APPROVED n PATENT PENDING n INDEPENDENTLY TESTED - for air- tightness by BRE nuaire.co.uk 29

30 THERMAL RECTANGULAR DUCTING ANCILLARIES x 90mm & 204 x 60mm INSULATED FLAT DUCT 1M LENGTH Part Number Duct Size @180l/s NTD-220-1M 220mm x 90mm Insulated Flat Duct 1M length @37l/s NTD-204-1M 204mm x 60mm Insulated Flat Duct 1M length INSULATED T-PIECE Part Number Duct Size @180l/s NTD-220-TP 220mm x 90mm Insulated T-Piece 6 - @37l/s NTD-204-TP 204mm x 60mm Insulated T-Piece INSULATED 90º HORIZONTAL BEND Part Number Duct Size @180l/s NTD H 220mm x 90mm Insulated 90º Horizontal Bend @37l/s NTD H 204mm x 60mm Insulated 90º Horizontal Bend INSULATED 45º HORIZONTAL BEND Part Number Duct Size @180l/s NTD H 220mm x 90mm Insulated 45º Horizontal Bend @37l/s NTD H 204mm x 60mm Insulated 45º Horizontal Bend INSULATED 90º VERTICAL BEND Part Number Duct Size @180l/s NTD V 220mm x 90mm Insulated 90º Vertical Bend @37l/s NTD V 204mm x 60mm Insulated 90º Vertical Bend INSULATED 45º VERTICAL BEND Part Number Duct Size @180l/s NTD V 220mm x 90mm Insulated 45º Vertical Bend INSULATED RECTANGULAR TO ROUND PLENUM Ø125mm Part Number Duct Size @180l/s NTD-220-PL 220mm x 90mm Insulated Plenum to Ø125mm @37l/s NTD-204-PL 204mm x 60mm Insulated Plenum to Ø125mm DUCT CONNECTOR CLAMPS Part Number Duct Size @180l/s NTD-220-CONL 220mm x 90mm Duct Clamps with Fixing Lugs NTD-220-CON 220mm x 90mm Duct Clamps no Fixing Lugs NTD-204-CONL 204mm x 60mm Duct Clamps with Fixing Lugs NTD-204-CON 204mm x 60mm Duct Clamps no Fixing Lugs

31 RECTANGULAR DUCTING cont. ANCILLARIES x 90mm & 204 x 60mm INSULATED RECTANGULAR TO ROUND ADAPTER Ø125mm & Ø150mm DUCT Part Number Duct Size @180l/s NTD-220-STR mm x 90mm Insulated Adapter to Ø125mm NTD-220-STR mm x 90mm Insulated Adapter to Ø150mm INSULATED 220mm RECTANGULAR ADAPTER TO 204mm RECTANGULAR DUCT Part Number Duct Size @180l/s NTD-220-RED mm x 90mm Insulated Adapter to 204mm THERMAL CIRCULAR DUCTING ANCILLARIES - Ø125mm INSULATED DUCT 1M LENGTH NTD-125-1M Ø125mm Insulated Duct 1M length INSULATED T-PIECE NTD-125-TP Ø125mm Insulated T-Piece INSULATED 90º BEND NTD H Ø125mm Insulated 90º Bend INSULATED 45º BEND NTD H Ø125mm Insulated 45º Bend INSULATED ROUND DUCT CLAMP WITH FIXING LUGS NTD-125-CONL Ø125mm Insulated Duct Clamps with Fixing Lugs INSULATED ROUND DUCT CLAMP NTD-125-CON Ø125mm Insulated Duct Clamps without Fixing Lugs CUTTING AID NTD-125- Ø125mm x 60mm Cutting aids for Ductmaster CUTTING AID Thermal Round Ducting CONDENSATION TRAP NTD-125- Ø125mm Ductmaster Thermal CON-TRAP Condensation Trap nuaire.co.uk 31

32 TYPICAL DUCTING ARRANGEMENT FOR A CEILING VOID MOUNTED MVHR UNIT USING RECTANGULAR INSULATED & UNINSULATED 204 x 60mm DUCTING Airflow colour key: Supply insulated Supply Extract Extract uninsulated uninsulated insulated Uninsulated round to rectangular fan plenum. (204 x 60mm) Part no. PVC540WH. Supply air to bedrooms via Air Valve (Part no. V125S) in ceilings. Inline attenuator. Part no. PVCSIL Duct support clamps for insulated ducting. (204 x 60mm) Part no. NTD-204-CON Part no. NTD-204-CONL. Top of ceiling void. Air brick. Part no. PVC505NS. Exhaust air from kitchen/bathroom to outside via air brick (Part no. PVC505NS). Supply air to lounge via Air Valve (Part no. V125S) in ceilings. Minimum 300mm Extract air from kitchen via Air Valve (Part no. V125S) in ceilings. Extract air from bathroom via Air Valve (Part no. V125S) in ceilings. Nuaire MRXBOX95B-LP1H ceiling void mounted unit. Intake air from outside via air brick (Part no. PVC505NS). Supply and extract ducts from external grilles to the unit should be insulated ducting. Air valve. Part no. V125S. Duct support clip for uninsulated ducting. (204 x 60mm) Part no. PVC122-5WH. Condensate drain. Part no. MVHR-DRAIN. Insulated 90 o horizontal bend. (204 x 60mm) Part no. NTD H. Insulated rectangular pipe. (204 x 60mm) Part no. NTD-204-1M. USING DUCT CLAMP NTD-204-CON & RECTANGULAR INSULATED DUCT PIPE OTHER INSULATED ANCILLARIES Clamp fastener. Remove the bottom part of the duct clamp from the top half of the clamp and using two screws attach the top half of the clamp to the installation position. Offer the rectangular duct pipe up to the installed portion of duct clamp and press the duct pipe onto the vertical spikes inside the clamp. With the duct length in position, offer the lower part of the duct clamp up to the top half of the clamp. Locate the fixing tabs on each side of the lower part of the duct clamp into the clamp fasteners each side of the top half of the clamp. Each duct joint should be supported by a clamp centrally positioned over each joint. Insulated fan plenum. (204 x 60mm) Part no. NTD-204-PL. Insulated T-piece. (204 x 60mm) Part no. NTD-204-TP. Insulated 90 o vertical bend. (204 x 60mm) Part no. NTD V. Insulated 45 o horizontal bend. (204 x 60mm) Part no. NTD H

33 TYPICAL DUCTING ARRANGEMENT FOR A WALL MOUNTED MVHR UNIT USING ROUND INSULATED & UNINSULATED Ø125mm DUCTING Airflow colour key: Supply insulated Supply Extract Extract uninsulated uninsulated insulated Uninsulated round duct connector. (Ø125mm) Part no. PVC593WH. Insulated round pipe. (Ø125mm) Part no. NTD-125-M. Uninsulated round duct (Ø125mm) Part no. PVC1200-SWH. Uninsulated 90 o bend. (Ø125mm) Part no. PVC590-WH. Louvre grille. Part no. PVC504. Exhaust air from kitchen/bathroom to outside via louvre grille. (Part no. PVC504). Minimum 300mm Intake air from outside via louvre grille. (Part no. PVC504). All duct between MVHR unit and atmosphere to be insulated*. Top of ceiling void. Nuaire wall mounted MVHR unit. Air supply to lounge via Air Valve in ceilings. (Part no. V125S) Air supply to bedrooms via Air Valve Extract air in ceilings. from (Part no. V125S) kitchen/ bathroom via Air Valve in ceilings. (Part no. V125S) Duct support clamp for insulated ducting. (Ø125mm) Part no. NTD-125-CON. Insulated 90 o bend. (Ø125mm) Part no. NTD H. Condensate drain. Part no. MVHR-DRAIN. Air valve. Part no. V125S. Duct clip for uninsulated duct. (Ø125mm) Part no. PVC596WH. USING DUCT CLAMP NTD-125-CON & ROUND INSULATED DUCT PIPE OTHER INSULATED ANCILLARIES Clamp fastener. Remove the bottom part of the duct clamp from the top half of the clamp and using two screws attach the top half of the clamp to the installation position. Offer the rectangular duct pipe up to the installed portion of duct clamp and press the duct pipe onto the vertical spikes inside the clamp. With the duct length in position, offer the lower part of the duct clamp up to the top half of the clamp. Locate the fixing tabs on each side of the lower part of the duct clamp into the clamp fasteners each side of the top half of the clamp. Each duct joint should be supported by a clamp centrally positioned over each joint. Insulated 45 o bend. (Ø125mm) Part no. NTD H. Insulated T-piece. (Ø125mm) Part no. NTD-125-TP. nuaire.co.uk 33

34 PVC DUCTING & ANCILLARIES DUCTMASTER PVC Nuaire provides a comprehensive range of ancillaries for all ducted applications to ensure the most cost-effective solution can be achieved. Ductmaster PVC is available as a circular duct, a slim duct which is ideal for apartments or ceiling voids, or a flat duct for where space is at a premium. THE ONLY COMPLETE SOLUTION ON THE MARKET n CIRCULAR DUCT - provides optimum system efficiency. Lightweight with simple push fit connections for ease of installation n FLAT DUCT SYSTEMS - ideal for apartments, ceiling voids, loft and other confined spaces where space is at a premium, without reducing whole system performance. Available in 204mm x 60mm and 220mm x 90mm n ATTENUATION - reduce duct noise as per ' Domestic Compliance Guide 2010' and noise requirements in 'Part F Building Regulations 2010'. Attenuator ducting also reduces cross talk through the ventilation systems, between rooms n WIDE SELECTION OF INTERNAL/ EXTERNAL GRILLES - designed to maximise system airflow performance and occupant comfort n FIRE PROTECTION - available for all duct systems to meet regulations n SELF SEAL - a simple and innovative solution for ducting systems to ensure the air leakage in and out of the duct joint is kept to an absolute minimum ALL YOUR REQUIREMENTS FROM A SINGLE SUPPLIER

35 PVC FLAT DUCTING FLAT CHANNEL 1.5M LENGTH PVC515WH 204mm x 60mm Flat Channel 1.5m Length PVC4015WH 121mm x 60mm Flat Channel 1.5m Length PVC015WH 110mm x 54mm Flat Channel 1.5m Length FLAT CHANNEL 2M LENGTH D mm x 60mm Flat Channel 2m Length D mm x 54mm Flat Channel 2m Length SLIM DUCT CONNECTORS PVC520WH 204mm x 60mm Slim Duct Connector PVC420WH 121mm x 60mm Slim Duct Connector PVC020WH 110mm x 54mm Slim Duct Connector CHANNEL CLIPS PVC122-5WH 204mm x 60mm Channel Clips PVC422WH 121mm x 60 mm Channel Clips PVC020WH 110mm x 54mm Channel Clips º HORIZONTAL BEND PVC550WH 204mm x 60mm 90 Horizontal Bend PVC450WH 121mm x 60mm 90 Horizontal Bend PVC050WH 110mm x 54mm 90 Horizontal Bend º VERTICAL BENDS PVC560WH 204mm x 60mm 90 Vertical Bend PVC460WH 121mm x 60mm 90 Vertical Bend PVC060WH 110mm x 54mm 90 Vertical Bend º HORIZONTAL BEND PVC555WH 204mm x 60mm 45 Horizontal Bend nuaire.co.uk 35

36 PVC FLAT DUCTING 45º VERTICAL BEND PVC575WH 204mm x 60mm 45 Horizontal Bend ADAPTORS PVC570WH 204mm x 60mm Ø125 Round to Rect Adaptor PVC470WH 121mm x 60mm Ø100 Round to Rect Adaptor PVC070WH 110mm x 54mm Ø100 Round to Rect Adaptor FLAT CHANNEL END CAP PVC518WH 204mm x 60mm Flat Channel End Cap PVC018WH 110mm x 54mm Flat Channel End Cap HORIZONTAL T-PIECE PVC582WH 204mm x 60mm Horizontal T-Piece PVC018WH 110mm x 54mm Horizontal T-Piece FAN PLENUM PVC440WH 204mm x 60mm Fan Plenum Ø100mm PVC540WH 204mm x 60mm Fan Plenum Ø125mm PVC641WH 204mm x 60mm Fan Plenum Ø1500mm PVC030WH 110mm x 54mm Fan Plenum Ø100mm PVC430WH 121mm x 60mm Fan Plenum Ø100mm AIR BRICK ADAPTOR PVC077WH 110mm x 54mm Airbrick Adaptor FLEXIBLE DUCT CONNECTOR PVC581WH 211mm x 64mm Flexible Duct Connector PVC481WH 121mm x 60mm Flexible Duct Connector PVC381WH 110mm x 54mm Flexible Duct Connector

37 PVC FLAT DUCTING 220 X 90MM DUCTING & ANCILLARIES Part Number @180l/s PVC910WH Flat Channel 1m Length PVC915WH Flat Channel 1.5m Length D Flat Channel 2M Length PVC961WH Elbow Bend with Rotating Offset Spigot 150mm PVC957WH Supertube to MegaDuct PVC977WH Double Airbrick Adapter PVC950WH Horizontal 90 Bend PVC955WH Horizontal 45 Bend PVC960WH Vertical 90 Bend PVC975WH Vertical 45 Bend PVC970WH Round to Rectangular Adapter PVC922WH Channel Clip 10 PVC920WH Flat Channel Connector 6 PVC982WH Horizontal T-Piece nuaire.co.uk 37

38 PVC CIRCULAR DUCTING RIGID ROUND PIPE 2M PVC1200-4WH Ø100mm x 2m 100mm Rigid Pipe PVC1200-5WH Ø125mm x 2m 125mm Rigid Pipe PVC1200-6WH Ø150mm x 2m 150mm Rigid Pipe PIPE CONNECTOR PVC493WH Ø100mm 100mm Pipe Connector PVC593WH Ø125mm 125mm Pipe Connector PVC693WH Ø150mm 150mm Pipe Connector º BEND PVC490WH Ø100mm 90 Bend 100mm PVC590WH Ø125mm 90 Bend 125mm PVC690WH Ø150mm 90 Bend 150mm º BEND PVC491WH Ø100mm 45 Bend 100mm PVC591WH Ø125mm 45 Bend 125mm INLINE BACKDRAUGHT SHUTTER PVC494WH Ø100mm 100mm Backdraught Shutter PVC594WH Ø125mm 125mm Backdraught Shutter PVC694WH Ø150mm 150mm Backdraught Shutter PIPE HANGER PVC496WH Ø100mm 100mm Pipe Hanger PVC596WH Ø125mm 125mm Pipe Hanger PVC696WH Ø150mm 150mm Pipe Hanger T-PIECE (MALE FITTING) PVC492M Ø100mm T-Piece 100 x 100 x Male fitting PVC592M Ø125mm T-Piece 125 x 125 x Male fitting

39 IN-LINE ATTENUATION Inline Attenuation available in 0.5m, 1m & 1.5m lengths. NUAIRE S NOISE SOLUTIONS n REGULATION DRIVEN - to reduce duct noise for designers Domestic Compliance Guide 2010 & noise requirements Part F 2010 n CORROSION PROOF - lightweight PVC removes the risk of corrosion n REDUCES CROSS-TALK - room to room noise n PREVENTS NOISE INGRESS - for inner city development n SPACE SAVING - slim line, low profile design for integration within your ducting system mm 1.0m 1.5m Tested by SRL Test Report Number: C/21196/RO Noise Reduction (db) TECHNICAL INFORMATION 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz -10 Frequency PRODUCT RANGE Silencer Code Description Width Length Height PVCSIL-500 System 204 Duct Silencer x 500mm 204mm 580mm 65mm PVCSIL-1000 System 204 Duct Silencer x 1.0m 204mm 1080mm 65mm PVCSIL-1500 System 204 Duct Silencer x 1.5m 204mm 1580mm 65mm THE LEVEL OF SOUND ABSORPTION Silencer Length 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz 500mm m m STATIC PRESSURE DROP IN PASCALS (Pa) VERSUS FLOW RATE (l/s) Approximate l/s PVCSIL-500 Pa PVCSIL-1000 Pa PVCSIL-1500 Pa nuaire.co.uk 39

40 PVC CIRCULAR DUCTING T-PIECE (FEMALE FITTING) TP150 x x 100mm T-Piece 150 x 150 x 100mm x 100 Female fitting REDUCING PIECE PVC119WH 125mm ID- Circular Reducing Piece mm OD PVC121WH 150mm ID- Circular Reducing Piece /100mm OD ROUND HOSE CONNECTOR PVC380WH Ø100mm Round Hose Connector FLAT CHANNEL WALL PLATE PVC114-4WH Ø100mm Wall Plate PVC114-5WH Ø125mm Wall Plate

41 PVC FLEXIBLE DUCTING FLEXIBLE RECTANGULAR DUCTING 3M LENGTH PVC333WH 114mm x 57mm Rectangular Flexible PVC Duct m length) PVC433WH 121mm x 60mm Rectangular Flexible PVC Duct (3m length) PVC533WH 211mm x 64mm Rectangular Flexible PVC Duct (3m length) FLEXIBLE ALUMINIUM DUCTING 5M LENGTH FLD100 5m x Ø100mm Aluminium Flexible Duct 100mm FLD125 5m x Ø125mm Aluminium Flexible Duct 120mm FLD150 5m x Ø150mm Aluminium Flexible Duct 150mm FLD200 5m x Ø200mm Aluminium Flexible Duct 200mm FLEXIBLE INSULATED DUCTING 5M LENGTH FLDI100 5m x Ø100mm Insulated Flexible Duct 100mm FLDI125 5m x Ø125mm Insulated Flexible Duct 120mm FLDI150 5m x Ø150mm Insulated Flexible Duct 150mm FLD1200 5m x Ø200mm Insulated Flexible Duct 200mm SEMI-RIGID ACOUSTIC DUCTING 3M LENGTH SRDI100 3m x Ø100mm Semi-Rigid Acoustic Ducting 100mm SRDI125 3m x Ø125mm Semi-Rigid Acoustic Ducting 125mm SRDI150 3m x Ø150mm Semi-Rigid Acoustic Ducting 150mm SRDI200 3m x Ø200mm Semi-Rigid Acoustic Ducting 200mm FLEXIBLE INSULATED DUCTING 5M LENGTH PVC363WH 3m x Ø100mm Flexible Ducting 100mm nuaire.co.uk 41

42 PVC GRILLES & TERMINALS WHITE STEEL EXTRACT / SUPPLY VALVES V100 Ø100mm 100mm dia Extract/Supply spigot Valve (White) V100S Ø100mm 100 dia Extract/Supply spigot Valve (Stainless Steel) V125S Ø125mm 125 dia Extract/Supply spigot Valve (White) V125S Ø125mm 125 dia Extract/Supply spigot Valve (Stainless Steel) The above resistances are based on 10mm opening setting. FILTERED INLET GRILLE 100IG 100mm x Filtered Inlet Grilles mm OD (White Only) LOUVERED GRILLE - WITH FLYSCREEN PVC104WH Ø100mm Louvered Grille with Flyscreen spigot PVC504WH Ø125mm Louvered Grille with Flyscreen spigot PVC604WH Ø150mm Louvered Grille with Flyscreen spigot PVC105WH Ø110mm Louvered Grille with Flyscreen spigot LOW RESISTANCE LOUVERED GRILLE - NO FLYSCREEN PVC104LR Ø100mm Low Resistance Louvered Grille spigot AIR BRICK PVC501WH 201mm x 57mm Air Brick with Shutter PVC505NS 201mm x 57mm Air Brick - No Shutter DOUBLE AIR BRICK PVC905WH 204mm x 60mm Double Air Brick Nuaire external grilles supplied White (RAL9010) as standard. For alternative colours please replace the WH at the end of the product code with BR for Brown (RAL 8017) l COT for Beige-Cotswold (RAL 1001) l TC for Red-Terracotta (RAL 8012) l

43 PVC GRILLES & TERMINALS UNIVERSAL COWL - SLATE GREY PVC4411 Ø100mm - Universal 100 x 150mm Cowl Ø150mm spigot GRAVITY SHUTTER WALL OUTLET PVC100WH Ø100mm spigot Wall Outlet with Gravity Flaps PVC101WH 110mm x 54mm Wall Outlet with Gravity Flaps PVC506WH Ø125mm spigot Wall Outlet with Gravity Flaps COWLED WALL OUTLET WITH DAMPER PVC102WH Ø100mm spigot Cowled Wall Outlet with Damper PVC103WH 110mm x 54mm Cowled Wall Outlet with Damper PVC502WH Ø125mm spigot Cowled Wall Outlet with Damper ROOF COWL 4RC Ø100mm spigot Roof Cowl 100mm WALL COWL 4WC Ø100mm spigot Wall Cowl 100mm WALL MOUNTING SHUTTERS PVCWALL/1 Ø100mm spigot Wall Mounting Gravity Operated Anti-Backdraught Shutters and Wall Duct WALL MOUNTING LOUVRE PVCWALL/2 Ø100mm spigot Wall Mounting Weather Louvre with Fly Screen and Telescopic Wall Duct Nuaire external grilles supplied White (RAL9010) as standard. For alternative colours please replace the WH at the end of the product code with BR for Brown (RAL 8017) l COT for Beige-Cotswold (RAL 1001) l TC for Red-Terracotta (RAL 8012) l nuaire.co.uk 43

44 PVC GRILLES & TERMINALS WALL MOUNTING RECTANGULAR COWLED OUTLET PVCWALL/3 Ø100mm Wall Mounting Rectangular spigot Cowled Outlet complete with Anti-Backdraught Damper and Telescopic Wall Duct 300mm - 550mm WALL MOUNTING CIRCULAR COWLED OUTLET PVCWALL/4 Ø100mm Wall Mounting Circular Cowled spigot Outlet with Telescopic Wall Duct 300mm x 550mm WALL MOUNTING AIRBRICK PVCWALL/5 Ø100mm Wall Mounting Air Brick with spigot Reducer 155mm Length of 110mm x 54mm Duct and Rectangular to 100mm dia Adaptor WALL MOUNTING WEATHER LOUVRE PVCWALL/6 Ø100mm Low Resistance Wall Mounting spigot Weather Louvre and Telescopic Wall Duct 300mm x 550mm HIGH RISE PVC2447T Ø100mm High Rise 100mm Round Cowl spigot WALL MOUNTING SHUTTER Nuaire external grilles supplied White (RAL9010) as standard. For alternative colours please replace the WH at the end of the product code with BR for Brown (RAL 8017) l COT for Beige-Cotswold (RAL 1001) l TC for Red-Terracotta (RAL 8012) l

45 PVC ATTENUATORS & ANCILLARIES SLIMDUCT SILENCER MEV-SIL10 204mm x 60mm Slimduct Silencer 1000mm MEV-SIL15 204mm x 60mm Slimduct Silencer 1500mm CONDENSATION TRAP CONTRAP100 Ø100mm Condensation Trap 100mm CONTRAP125 Ø125mm Condensation Trap 125mm ONTRAP150 Ø150mm Condensation Trap 150mm INLINE CONDENSATION DRAIN MVHR-DRAIN Ø22mm Inline Condensate Drain DYNO TIES DT33 150mm - Dyno Ties up to Ø200mm mm OD DUCT ACCESSORIES PVCDSEAL N/A Duct Sealant PVC50TP45 N/A Aluminium Duct Tape 45m PVCFSEAL N/A Intumescent Duct Sealant CIRCULAR FIRE DAMPER CFD-100-E60S Ø100mm Circular Fire Damper 100mm CFD-125-E60S Ø125mm Circular Fire Damper 125mm CFD-160-E60S Ø160mm Circular Fire Damper 106mm CFD-200-E60S Ø200mm Circular Fire Damper 200mm CIRCULAR FIRE DAMPER AIR VALVE V-FD100-E60S Ø100mm Circular Fire Damper Air Valve mm V-FD125-E60S Ø125mm Circular Fire Damper Air Valve mm nuaire.co.uk 45

46 PVC ATTENUATORS & ANCILLARIES FIRE WRAP PVC mm x 54mm Fire Brake Duct Connector x 50 PVC mm x 60mm Fire Brake Duct Connector x 60 PVC mm Intumescent Fire Brake FW110 x mm x 54mm Fire Wrap FW204 x mm x 60mm Fire Wrap FWS110 x mm x 54mm Fire Collar FWS204 x mm x 60mm Fire Collar

47 RADIAL NRD75 DUCTMASTER RADIAL DUCTING Nuaire Ductmaster Radial Ducting (NRD75) is a range of ducting and ancillaries intended for installation in domestic properties. Nuaire radial ducting is available in Ø75mm with a range of components compatible with the Nuaire Ø125mm Thermal Ductmaster range. THE ONLY COMPLETE SOLUTION ON THE MARKET n REDUCES INSTALLATION TIME - unlike other types of ducting systems, Nuaire s Radial Ducting design negates the need for multiple lengths of duct, bends and ancillaries, minimising duct leakage and reducing installation time n DUCTMASTER RADIAL DUCT - is designed to use with Nuaire Thermal Ducting and allows quick and easy installation without the need for any tapes or sealants n PROVIDES LOWER LEAKAGE - will achieve a level of leakage substantially lower than the maximum allowed for a class A duct as defined in DW/143 (Ductwork leakage testing). Nuaire radial ducting is fully SAP Appendix Q recognised for use in new build properties n REDUCES CONNECTIONS - can be easily manipulated to suit changes in direction, reducing the need for connections which saves time on installation INSTALLATION OPTIONS This is an example of a variant where the Manifolds (air distribution boxes) have been mounted above a lowered ceiling. Exhaust air to outside via wall grille. Ductmaster Thermal Duct. The lowered ceilings will have to be constructed in such a way that the air distribution boxes remain accessible. A centralised Heat Recovery unit distributes and extracts the air to and from the dwelling through the Manifold outlets and Ductmaster Radial Duct. Ductmaster Thermal Duct is used in the cold space. Supply air from outside via wall grille. MRXBOX95 MVHR unit. Ductmaster Thermal Duct. Manifold. Ductmaster Radial Duct. Manifold. Extract air via Plenum and Air Valve in the ceiling. Extract air via Plenum and Air Valve in the ceiling. Air supply via Plenum and Air Valve in the ceiling. Ductmaster Radial Duct. Air supply via Plenum and Air Valve in the ceiling. nuaire.co.uk 47

48 RADIAL NRD75 40M OF BLUE RADIAL DUCT Part Number Duct Size Description NRD75-B40M 40m Length x Ø75mm Blue Radial Duct 40M OF RED RADIAL DUCT Part Number Duct Size Description NRD75-R40M 40m Length x Ø75mm Red Radial Duct 8-PORT MANIFOLD BOX Part Number Duct Size Description NRD75-MANCOM-150 Ø75mm Manifold Box with 8 Ports 12-PORT MANIFOLD BOX Part Number Duct Size Description NRD75-MAN-150 Ø75mm Insulated Manifold with 12 Ports 8-PORT MANIFOLD BOX Part Number Duct Size Description NRD75-MAN-125 Ø75mm Insulated Manifold with 8 Ports WALL PLENUM WITH GRILLE Part Number Duct Size Description NRD75-WG Ø75mm Wall Plenum with Grille FLOOR PLENUM WITH GRILLE Part Number Duct Size Description NRD75-FG Ø75mm Floor Plenum with Grille RESTRICTION RING Part Number Duct Size Description NRD75-RING Ø75mm Restriction Ring DUST CAP Part Number Duct Size Description NRD75-DUCT-CAP Ø75mm Dust Cap (Red) for Ducting MANIFOLD TO DUCT CONNECTOR Part Number Duct Size Description NRD75-MAN-CON Ø75mm Manifold to Duct Connector

49 RADIAL NRD75 90 MANIFOLD TO DUCT CONNECTOR Part Number Duct Size Description NRD75-MAN-90-CON Ø75mm 90 Manifold to Duct Connector DUCT CONNECTOR Part Number Duct Size Description NRD75-DUCT-CON Ø75mm Duct Connector 90 BEND DUCT CONNECTOR Part Number Duct Size Description NRD75-DUCT-90 Ø75mm 90 Bend Duct Connector 90 BEND WITH FIXING PLATE Part Number Duct Size Description NRD75-DUCT-90FP Ø75mm 90 Bend with Fixing Plate 2 PORT CEILING VALVE PLENUM CONNECTOR Part Number Duct Size Description NRD75-VPL Ø75mm 2 Port Ceiling Valve Plenum Connector 2 PORT WALL VALVE PLENUM CONNECTOR Part Number Duct Size Description NRD75-HPL Ø75mm 2 Port Wall Valve Plenum Connector DUST CAP FOR CONNECTORS Part Number Duct Size Description NRD75-CON-CAP Ø75mm Dust Caps (Red) for Connectors MOUNTING BRACKET Part Number Duct Size Description NRD75-MB Ø75mm Mounting Bracket CEILING VALVE Part Number Duct Size Description NRD75-VALVE Ø75mm Ceiling Valve DUCT CONNECTOR Part Number Duct Size Description NRD75-SEAL Ø75mm Sealing Rings nuaire.co.uk 49

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES The Range 1 HIGHEST INDOOR AIR QUALITY IN NEW HOMES NUAIRE S Q-AIRE Innovation at its best Since our inception in 1966, we have pioneered a number of new ventilation strategies and products now widely

More information

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide 1.0 INTRODUCTION NTD-125-*, NTD-204-* & NTD-220-* Nuaire Installation Guide Nuaire Ductmaster Ducting (NTD) is a range of ing and ancillaries intended for installation in domestic properties. Nuaire Ducting

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

FOR EVERY DUCTING SOLUTION DUCTING & ANCILLARIES

FOR EVERY DUCTING SOLUTION DUCTING & ANCILLARIES FOR EVERY DUCTING SOLUTION DUCTING & ANCILLARIES DUCTING & ANCILLARIES Ductmaster is a fully comprehensive range of installation ancillaries for all ducted applications, to ensure you achieve the most

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

RESIDENTIAL VENTILATION DUCTING SOLUTIONS RESIDENTIAL VENTILATION DUCTING SOLUTIONS NUAIRE S PEDIGREE ABOUT NUAIRE Nuaire have designed and manufactured innovative, quality products for home and overseas markets since 1963. The group has extensive

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL NUAIRE S PIV: HALL CONTROL The DRIMASTEReco Range The DRIMASTER-ECO range provides whole home ventilation using the Positive Input Ventilation principle, which introduces fresh filtered air into the dwelling

More information

MRXBOX95AB-WH2 (with automatic summer bypass)

MRXBOX95AB-WH2 (with automatic summer bypass) MRXBOX95AB-WH (with automatic summer bypass) MRXBOX95AB-WH is designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

Polypipe Ventilation Specifiers Guide

Polypipe Ventilation Specifiers Guide Uniclass L75344 CI/SfB (57.5) X PVSB-2 May 215 Polypipe Ventilation Specifiers Guide Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Intermittent Extract and Decentralised Mechanical

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS. - SMA COMMERCIA HEAT RECOVERY SYSTEM OW DEPTH, HEAT RECOVERY UIT WITH MUTIPE SPIGOTS AD ECOSMART COTROS. 34 09 085 800 AIR HADIG UITS (AHU S) TECHICA IFORMATIO BEEFITS OW DEPTH 185MM The shallowest available,

More information

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM SOLAR PRE-HEAT VENTILATION SYSTEM SUNWARM USES SOLAR ENERGY TO REDUCE THE HEATING DEMAND OF THE HOME AS WELL AS PROVIDING A COMPLETE VENTILATION SOLUTION. 76 BENEFITS Sunwarm Air provides both a ventilation

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance MRXBOX95AB-WH1 Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction

More information

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

SPECIFICATION GUIDE. Tel DOMUS VENTILATION SPECIFICATION GUIDE Tel 3443 715 523 www.domusventilation.co.uk @DomusVent DOMUS VENTILATION Contents Introduction 3 Best Practice Guide 4 Indoor Air Quality 8 Mechanical Ventilation Products 9 DME Controls

More information

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXBOX95-WM2 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Viewpoint August 2012 Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system Dr Sarah Price and Helen Brown Summary Mechanical Ventilation and Heat

More information

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover Automatic & Manual Hand dryers for Commercial Applications 1.1kW Compact Eco Swift 409733 409734 Satin Stainless Steel 409735 Polished Stainless Steel Intelligent sensing, element auto switch off when

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance MRXBOX95-WM2H Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications. Centra dmev Unit 62kg* carbon 80% energy E S P l i g i b l e Q P P E N D I X Part F compliant, System 3 IPX4 rated Continuous mechanical extract. Constant volume option. SP ppendix Q eligible - Low SFP

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)

IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev) IMPROVIG IDOOR AIR QUAITY I EW HOMES MECHAICA EXTRACT VETIATIO (MEV & dmev) UAIRE S PEDIGREE Proud to Build British uaire is a world leader in the design and manufacture of fans and ventilation systems.

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref. Lo-Carbon MULTIVENT MVDC-MS & VENTILATION SYSTEMS Installation and Wiring Instructions Stock Ref. N MVDC-MS 76A 98 0-0V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE

More information

Building Regulations 2010: What it means to you.

Building Regulations 2010: What it means to you. Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both

More information

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS. TWIFAS COMPACT & POWERFU, IDEA FOR ARGER ROOM APPICATIOS WHIST MAITAIIG OW OISE EVES. 9 85 8 5 Speed Control TWI FAS BEEFITS COMPACT & POWERFU Small design, high performance up to 5I/s - ideal for larger

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

DUCTING FOR HRV SYSTEMS The distribution of airflows

DUCTING FOR HRV SYSTEMS The distribution of airflows DUCTING FOR HRV SYSTEMS The distribution of airflows As we saw in my two previous articles, Heat Recovery Ventilation (HRV) gives healthy and comfortable ventilation whatever the weather. And in wintertime,

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

ventilation solutions

ventilation solutions ventilation solutions for apartments and communal residences Helping to create a relaxing, ventilation solutions comfortable environment Nuaire is the market leader in the design and manufacture of energy

More information

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. CI/SfB (57.7) 3rd Edition WINNER2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. Lo-Carbon Centra Allowing you to help the environment

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4. MRXBOX95-LH1/LH2 Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction Unit must

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

LANDLORDS & LETTINGS VENTILATION SOLUTIONS LANDLORDS & LETTINGS VENTILATION SOLUTIONS CREATING A HEALTHY INDOOR ENVIRONMENT CONTENTS INTRODUCTION... 3 WHY IS VENTILATION IMPORTANT?...4 CURE CONDENSATION FOR GOOD... 5 THE DRIMASTER RANGE... 6 SINGLE

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

VENTILATION DESIGNED FOR CARE HOMES

VENTILATION DESIGNED FOR CARE HOMES CI/SfB (57) Uniclass Pr_65_67_29 October 2017................................ ............................................................................. Contents Ventilation designed for Care Homes

More information

Airflex Radial & ISO Thermal pipe

Airflex Radial & ISO Thermal pipe Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

Centrif Duo & Centrif Duo Plus

Centrif Duo & Centrif Duo Plus Centrif Duo & Centrif Duo Plus Installation and Wiring Instructions Stock Ref. N Centrif Duo P 25 61 20D Centrif Duo T 25 62 20D Centrif Duo DP 25 63 20D Centrif Duo HTP 25 64 20D Centrif Duo Centrif Duo

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. 01 Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. This fan can be wall, ceiling, inline or window mounted You must ensure that any emissions

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

Sentinel Demand Energy Recovery Ventilation

Sentinel Demand Energy Recovery Ventilation Welcome to the world of Sentinel Demand Energy Recovery Ventilation Sentinel Totus 2 Demand Energy Recovery Ventilation (D-ERV) is a new heat recovery demand ventilation system designed to meet modern

More information

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air. MRXBOX95-WA Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction Figure 2. Fixing

More information

ventilation solutions for schools, academies, colleges and universities

ventilation solutions for schools, academies, colleges and universities for schools, academies, colleges and universities Creating environments that inspire learning We eliminate the risk and high cost of ventilation by designing and manufacturing innovative products for homes

More information

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range & 300 Exceptionally low energy consumption High Efficiency, Low Profile Heat Recovery Range & 300 High Efficiency, Low Profile Heat Recovery Range High-efficiency, low profile MVHR units to deliver exceptionally

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

MVHR & MEV VENTILATION GUIDE 2017

MVHR & MEV VENTILATION GUIDE 2017 MVHR & MEV VENTILATION GUIDE 2017 Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation Rigid and Semi-Rigid Duct Systems 1 All prices quoted exclude VAT and do not include trade discounts.

More information

VENTILATION PRODUCTS & CONTROLS FOR COMMERCIAL KITCHENS

VENTILATION PRODUCTS & CONTROLS FOR COMMERCIAL KITCHENS VENTILATION PRODUCTS & CONTROLS FOR COMMERCIAL KITCHENS Energy Efficient Control Cheetah Energy Control NUAIRE - FOR THE COMPLETE VENTILATION SOLUTION A COMPLETE VENTILATION SERVICE FROM DESIGN TO CUSTOMER

More information

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance TOP ECOSMART TWINFANS (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU INDOOR USE ONLY Introduction

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User/Homeowner Guide

More information

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make

More information

Warnings, Safety Information and Guidance

Warnings, Safety Information and Guidance EN SR700 SRHRV Fan TP600 Single Room Heat Recovery Ventilation Fan Unit SRC Controller TP590 Single Room Heat Recovery Ventilation Controller Unit Product Installation Manual ventilation systems Warnings,

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

SMOKE CONTROL - NEW DIRECTIONS

SMOKE CONTROL - NEW DIRECTIONS SMOKE CONTROL - NEW DIRECTIONS Nuaire provides the total package for smoke control with schemes designed to fully comply with statutory and regulatory requirements. Our team of skilled engineers include

More information

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra Centrifugal Fan Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units Product Manual ventilation systems 2 PCT Patent Application No PCT/GB2009/000114 Contents Introduction...................................

More information

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHHR125DC Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use "WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor Installation, Operating and Maintenance Instructions domestic and commercial use Page 2 Contents Section Page Number Introduction 3 How

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

Caice Attenuator Selector - Specifier Edition

Caice Attenuator Selector - Specifier Edition Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

ECO dmev Decentralised MEV

ECO dmev Decentralised MEV ECO dmev Decentralised MEV The ECO dmev has been designed and developed to offer the market a constant volume, continuously running decentralised extract fan to achieve the lowest power consumption, the

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific

More information

Xcell 270 Longlife DC wholehouse heat recovery unit

Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270 Longlife DC wholehouse heat recovery unit Installation and maintenance instructions Xpelair Xcell 270 Longlife DC wholehouse heat recovery unit Xcell 270, Xcell 270BP Please leave this leaflet

More information

Zehnder Comfosystems. ComfoAir 180 Datasheet

Zehnder Comfosystems. ComfoAir 180 Datasheet Zehnder Comfosystems Heating Cooling Fresh Air Clean Air ComfoAir 180 Datasheet Zehnder Comfosystems ComfoAir 180 Physical specifications The Zehnder ComfoAir 180 heat recovery ventilation system is an

More information

Intelligent Air Solutions

Intelligent Air Solutions Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent

More information