OIL SKIMMERS. Engineering Technologies

Size: px
Start display at page:

Download "OIL SKIMMERS. Engineering Technologies"

Transcription

1 OIL SKIMMERS Skylark engineering technologies manufacturers a wide variety of oil skimmer to meet any size application. We manufacture skimmers that can remove from 1 gallon per hour to 200 gallons per hour. We offer turnkey systems with a variety of motors, heat options, stands, and oil concentrate. Our skimmers are used on parts washers, in car washes, wells, steel mills, component cleaning machine, sugar industries, food pro sing, and any other industry where hydrocarbons need to be removed. WORKING: Although designs vary, all oil skimmers rely on specific gravity, surface tension and a moving medium to remove floating oil from a fluid's surface. Floating oil and grease cling to skimming media more readily than water, and water has little affinity for the media. This allows skimming media in the shape of a belt, disk, drum, etc. to pass through a fluid surface to pick up floating oil and grease with very little water. This oily material is subsequently removed from the media with wiper blades or pinch rollers. Oil skimmers are simple, dependable and effective tools for removing oil, grease and other hydrocarbons from water and coolants. Often, an oil skimmer by itself can achieve the desired. level of water purity. Applications for Industrial Oil Skimmers Wastewater Sumps Coolants and Cutting Fluids Heat Treating Parts Washers Food Processing Facilities Steel Mills/Scale Pits Parking Lots, Garages and Service Facilities Outdoor Ponds, Lakes, Basins, Etc. Recovery/Monitoring Wells Operating Conditions All oil skimmers have a moving medium, and possibly other parts, immersed in the liquid. The performance and life of the pickup medium, wiper blades, pulleys, etc. are affected by different conditions. These conditions include temperatures in and out of the liquid, ph of the solution, and the presence of solvents or other reactive chemicals.

2 OIL SKIMMING SYSTEMS ARE DESIGNED FOR SPECIFIC TYPES OF APPLICATIONS. THEY GENERALLY FALL INTO THREE CATEGORIES: 1. Skimmers designed for emergency oil spill situations that have a very high removal rate, but operate very inefficiently require regular maintenance and operator attention, high water removal rate, prone To clogging fuzzy hair "Rope Mop" Type systems, floating weir/pumping systems. 2. Skimmers designed for very small tight applications that cover only a small slice of surface area Disk", "Belt" Type Systems. 3. Skimmers designed for continuous operation in industrial applications Tube Type" systems. Belt type oil skimmer Applications The Belt type oil skimmer is designed for those applications where other models provide excess capacity, or physically will not fit. From a mere shimmer on top of water to a heavy oil slick, the Belt type oil skimmer performs efficiently, removing up to 20 gallons of oil per hour. Wastewater sumps Parts washers Coolant systems Heat treating fluids Food processing plants Parking lots, garages, and service facilities Outdoor ponds, lakes, and basins Underground tanks Ships' bilges Aircraft service areas and tarmac runoff Truck, locomotive, and other mobile equipment washing facilities Features Requires only a small area in the tank or sump Easy mounting High temperature capability Chip resistant powder finish Hazardous duty and food grade options Custom designs and turnkey systems available Fast cleaning with minimal maintenance

3 SPECIFICATIONS FOR BELT OIL SKIMMERS: OIL REMOVAL RATE: 60 lph with standard tail pulley. 75 lph with high capacity tail pulley. (Removal rate is based on 30 weight oil in water.) Tail Pulley: Specify standard or high capacity. (The high capacity option uses a patented pulley design That improves the adherence of oil to the inside Motor: Fractional hp, TEFC, gear motor operating on either 115/230VAC, single phase, 60Hz or 230/460 VAC, Optional: 50Hz power source; explosion Proof; drip proof; Belt Width: 4 in. (10 cm). Belt Length: User specified (up to 100', measured from the center of head pulley to center of tail pulley) Belt Material:

4 TUBE TYPE OIL SKIMMERS How The Skimmer Works: The Tube type Oil Skimmer uses a specially formulated 1.0 diameter collector tube (Fish Tube) that is sized in length for the application and welded into a continuous loop. The 1.0 Fish Tube collector tube floats on the surface of water and is driven in a continuous loop by the skimmer. Oils, fats, and grease cling to the outside surface of the Fish Tube and are drawn into the skimmer. The material drawn into the skimmer is scraped off the Fish Tube by abrasive resistant scrapers (Nitrile scrapers) and flows into a sludge pan with drain coupling. The clean side of the Fish Tube collector tube is then driven back to the surface of the water by the skimmer to remove more material. The Tube Type Oil Skimming System Is Supplied Complete With: 0.25 HP, Three phase, AC Geared Motor of fixed 30 rpm. Front safety guard with integral Nitrile scrapers & pressure blocks. Lubed for life gear reducer, bearings and sprockets. Quick connect and release Drive and Pulley Wheels. Single ring replaceable Nitrile Drive and Pulley Wheel Wear Rings. Drive and Pulley Wheel timing belt drive system with belt tension device. Rear safety guard. Operating & Maintenance Manual Weight Lbs. Dimensions (Length x Width x Height) x356 x362. Key Features: Compact design fits almost any tank or pit. Explosion proof and wash down duty motors available. Tubes with up to 100 foot reach. Safety shut off switch for safe maintenance. Simple and effective drive design for lasting performance. Unique wiping system for more effective oil removal. Weighs 74 pounds. Units with removal rates of up to 100 gph.

5 REMOVAL RATES Light Oils & Grease - 14 GPH Medium Oils & Grease - 34 GPH Heavy Oils & Grease - 80 GPH The Benefits of Oil Skimmers Oil skimmer would be ready to perform continuously for 24 hours and for 365 days a year. Suitable rain hood cover would be provided to protect the mechanism during rainy seasons if the system is to be k e p t in open. Imported polymer Tube is used for more tube travel life as well maximum oil removal. Tube has property of floating on top of the liquid and thus is capable of collecting maximum surface of the tank liquid. The AC 3Phase Motors we use are absolute i n d u s t r i a l g r a d e m o t o r s w i t h c o m p l e t e h e a v y d u t y construction and is guaranteed for continuous duty performance. General Observations: A. Tube type oil skimmer in designed for the withdraw of freefloating oils from the surface of water in a sump, The main advantage of tube type oil skimmer in that the tube floats on the water and than more free flouting oil sticks to the tube B. The Skimmer shall be placed on fabricated stand which maintain the height approximately 1 meter above the ground level so that oil can collected in a oil tank. An oil collection tray is mounted on bare place C. Polymer tube is oil and grease, while being resistance abrasion. Nitral materialscrapper to used to remove oil from the tube which is replaceable

6 APPLICATIONS FOR INDUSTRIAL OIL SKIMMERS Wastewater sumps Coolant systems Food processing plants Parking lots, garages and service facilities Outdoor ponds, lakes and basins Underground tanks Ships bilges Aircraft service areas and tarmac runoff Truck, locomotive and other mobile equipment washing Facilities Steel Manufacturing Plants How Oil Skimmer Collector Tubes Works: The Tube floats on the surface of water and is driven in a continuous loop by the oil skimmer. Free floating oils, fats and grease cling to the outside surface of the collector tube and are pulled into the oil skimmer where they are removed by tube scrapers. The material removed flows into a oil collection tray. The collector tube is then driven back to the water to remove more floating oil. How Oil Skimmer Collector Tubes Works: The Tube floats on the surface of water and is driven in a continuous loop by the oil skimmer. Free floating oils, fats and grease cling to the outside surface of the collector tube and are pulled into the oil skimmer where they are removed by tube scrapers. The material removed flows into a oil collection tray. The collector tube is then driven back to the water to remove more floating oil.

7 DISK SKIMMER Ø220, 300 or 450mm The inexpensive way to remove unwanted tramp oils from Coolants and parts washers, but with all the quality that you expect from Effective. Removes up to 20 liter of oil or more of medium weight oil per Hour. Compact Use it almost anywhere a flat surface is available for mounting. Portable Weighs less than 10 pounds, installs in no time, and runs on 110v power. Complete. Put it to work right out of the box, or add the optional coolant saving decanter for a more efficient skimming system. Standard Features: Available in 12 and 18 diameters 110v fan cooled motor High temperature disk material Quality construction Optional Features: 24 hour timer Coolant saving decanter Stainless steel disk skimmers for harsh chemical environments! Introducing a disk skimmer constructed of stainless steel for those applications where carbon steel may fail. Perfect for parts washers or plating Quick Summary: The inexpensive way to remove unwanted tramp oils from coolants and parts washers. Use it almost anywhere a flat surface is available for mounting. Weighs less than 10 pounds and installs in no time. Put it to work right out of the box, or add the optional coolant saving decanter for a more efficient skimming system. Highlights: Disk available in 12 and 18 diameters. 110v 60Hz. fan-cooled motor. High temperature disk material available. Quality construction. Available in Stainless Steel with timer. Removes up to 1-1/2 gallons of medium weight oil per hour. Optional coolant saving decanter available. Tanks!

8 LAMINAR AIR FLOW Skylark is designed and manufacture with precision, the Laminar Air Flow is ideal for Operator Protection, Product Protection and Environment Protection. Based on the smooth working profile and high-end performance of our Laminar Air Flow, we are ranked amidst notable Laminar Air Flow Manufacturers, Suppliers and Exporters from India. Furthermore, Laminar Air Flow can be customized to suit the precise requirements of the clients Specification: Powder coated Mild Steel, SS 304 / SS 316 / SS 316L or a combination of both Pre-filter (95% down to 5 micron) Mini plate HEPA Filter Supply (99.999% down to 0.3 micron) Motor blower Assembly : Crompton make variable speed motor mounted on PU coated.frp Blower with aluminum power coated impeller Noise Level: <65Db at 01 meter from face of the equipment HORIZONTAL LAMINAR AIR FLOW The Horizontal Laminar airflow provides product protection within the work area, which is confined by removable clear glass panels Or polycarbonate shutter. Room air is taken in from the bottom of the cabinet through a pre-filer with 90% efficiency which traps particles of 10µ and above. Air is spread evenly across the HEPA filter, thereby providing a steam of clean air within the work area of the cabinet; this removes all contaminated air from the interior. Perforated Stainless Steel diffuser screen protects the HEPA filter and maintain uniform air flow velocity within the work area Easy disassembly for access through a small door. Front angular 10 degree slope helps reduce operator fatigue while working on the cabinet.

9 TECHNICAL SPECIFICATION Name of Equipment Horizontal Laminar Air Flow Model SET-V-2X2 SET-V-3X2 SET-V-4X2 SET-V-6X2 External LxWxH Dimension ( MM) Work Area LxWxH Dimension (MM) Material of Construction Table Top Side Glass 705X870X XX870X XX870X XX870X X 610 X X 610 X X 610 X X 610 X572 M.S sheet with Powder coating of 1.5mm thickness /stainless still Grade 304, 1.2mm thickness for S.S model. 1.2 mm S.S 304 Sheet of matt finished. 6mm Float Glass encased Stainless still channel. Font Door Frameless gas spring loaded swiping Type Polycarbonate 06mm Thickness.(Optional ) Wheels And Lugs Design and Classification PU solid wheels with plated bracket & metallic powder coated Leveling Lugs for GI model PU solid wheels with S.S 304 bracket and solid S.S 304 leveling lugs for S.S model Front bottom loading pre- filter / complete work Area will be of S.S 304 including HEPA Grill. (Optional )Table top and light canopy internal surface for GI model and S.S model Angled front slop of 10 Degrees to reduces Operator fatigues while working Stage of filters 1) Pre-filter = 10micron with an efficiency 90% washable HDPE Media in FRP PU coated Frame for GI model for S.S304 Model the frame will be in S.S 304 2) Mini plate HEPA filter incased in aluminum frame Final = 0.3micron with an efficiency of % (anti microbial treated media ) Motor blower Velocity Noise Level Pressure Gauge ''Crompton'' make variable speed motor mounted on PU coated. FRP Blower with aluminum power coated impeller 100 FRM At 6'' from face of the filter <65Db. at 01 meter from face of the equipment Inclined Tube Acrylic monometer 0 to 40 mm wg/dyer make mangnahelic differential Switches and speed control Microprocessor control feature touch switch panel Electrical Fluorescent Lighting 18 watt -02Nos 18 watt -03Nos 36 watt -02Nos 36 watt -04Nos Chock for 18 watt -03Nos 18 watt -04Nos 36 watt -03Nos 36 watt -05Nos Ultra violet 1.5 feet length 1.5 feet length 03 feet length 03 feet length

10 VERTICAL LAMINAR AIRFLOW Skylark Vertical Laminar Flow Unit is designed specifically for product protection. The Cabinet is a clean bench which provides ultra clean sterile HEPA filtered class 100 air in an isolated area for operations requiring a particulate-free environment where the highly sensitive process activities are carried-out. Air is spread evenly across the HEPA filter, thereby providing a stream of clean air within the work area of the cabinet; this removes all contaminated air from the interior. Perforated stainless still diffuser screen protects the HEPA filter and maintain uniform air flow velocity within the work area.vertical laminar flow occupies less space and can be installed in a small area. Advantage of working from both the sides and visibility from all sides The Vertical Laminar Flow Unit draws air in through the top of the unit through a pre-filter with 90% efficiency which traps particles of 10µ and above. Through a plenum and vertically down over the worksurface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in a horizontal laminar flow cabinet. The laminar air flow cabinets are used for work with low-risk substances and materials, when protection of working material from environment is required or work with item requires a sterile working zone. Cabinets are used for equipment of local workplaces in medical, pharmaceutical and other institutes with high requirements for air cleanliness in the working zone. Revise laminar air flow: Specification: Continuous, clean, laminar down flow of Class 100 air supplied to work area in order to suppress Any dust clouds produced during open powder processing And eradicate and capture airborne particles from the operator's breathing zone Triple Stage filtration

11 Name of Equipment Model Vertical Laminar Air Flow SET-V-2X2 SET-V-3X2 SET-V-4X2 SET-V-6X2 External LxWxH Dimension ( MM) Work Area LxWxH Material of Construction Table Top Light Box Front Grill Side Glass Font Door 705X870X X870X XX870X X870X X 610 X X 610 X X 610 X X 610 X572 Stainless steel 304 Sheet with Mat finishing of 80micron 1.2 mm thickness 1.2 mm S.S 304 Sheet of matt finished. Internal cover of light box is S.S304 mat finished Capsule Type holes S.S 304 with mat Finishing 6mm Float Glass encased Stainless still channel. Frameless gas spring loaded swiping Type Polycarbonate 06mm Thickness (Optional ) Wheels And Lugs Design and Classification Stage of filters Motor blower Assembly Velocity Noise Level PU solid wheels with plated bracket & metallic powder coated Leveling Lugs for GI model PU solid wheels with S.S 304 bracket and solid S.S 304 leveling lugs fors.s model Front bottom loading pre- filter / complete work Area will be of S.S304 including HEPA Grill. Table top and light canopy internal surface for GI model and S.S model Angled front slop of 10 Degrees to reduces Operator fatigues while working 1) Pre-filter = 10micron with an efficiency 90% washable HDPE Media in FRP PU coated Frame for GI model for S.S304 Model the frame will be in S.S 304 2) Mini plate HEPA filter incased in aluminum frame Final = 0.3micron with an efficiency of % (anti microbial treated media ) ''Crompton'' make variable speed motor mounted on PU coated. FRP Blower with aluminum power coated impeller 100 FRM At 6'' from face of the filter <65Db. at 01 meter from face of the equipment Pressure Gauge Pressure Gauge Dyer make mangnahelic differential pressure gauge 0 to 40 mm wg SWITCHES AND SPEED CONTROL MICROPROCESSOR CONTROL FEATURE TOUCH SWITCH ELECTRICAL FLUORESCENT LIGHTING CHOCK FOR LIGHTING 18 WATT - 02NOS 18 WATT - 03NOS 18 WATT -03NOS 36 WATT -02NOS 36 WATT -04NOS 18 WATT -04NOS 36 WATT -03NOS 36 WATT -05NOS ULTRA VIOLET LIGHT 1.5 FEET LENGTH 15 WATTS 1.5 FEET LENGTH 15 WATTS 03 FEET LENGTH 30 WATTS 03 FEET LENGTH 30 WATTS

12 BIO SAFETY Bio Safety Cabinet comes with Cabinet Class II with open front design and functions as negative pressure generation module, providing recirculation of mass flow of HEPA filtered air that offers optimum protection to users, products as well as the surrounding environment. Other than this, the other options include totally closed bio safety cabinet class III that is a ventilated enclosure with air tight construction and allows experiments/procedures to be performed using rubber gloves. The primary purpose of a BSC is to serve as a means to protect the laboratory worker and the surrounding environment from pathogens. All exhaust air is HEPA filtered as it exits the bio safety cabinet, removing harmful bacteria and viruses. This is in contrast to a laminar flow clean bench, which blows unfiltered exhaust air towards the user and is not safe for work with pathogenic agents. Neither are most BSCs safe for use as fume hoods. Likewise, a fume hood fails to provide the environmental protection that HEPA filtration in a BSC would provide. However, most Classes of BSCs have a secondary purpose to maintain the sterility of materials inside Applications: Biological Safety Cabinet Class II is designed to meet diverse applications in Life science Clinical Microbiology Genetics Plant and animal cell culture Molecular biology Pharmaceutical and industrial laboratory Dimensional Specification 600mm x 600mm x 600mm Size Working Bench 900mm x 600mm x 600mm 1200mm x 600mm x 600mm 1800mm x 600mm x 600mm

13 CLASS II SKYLARK Biological Safety Cabinet Class II Type SET-BSC II Series is designed with inward air flow velocity (0.55m/s) for personnel protection, HEPA- filtered laminar airflow for product protection and HEPA-filtered exhausted air for environmental protection. It is suitable for microbiological research in the absence of volatile or toxic chemicals and radionuclide, since air is re-circulated within the work area. FEATURES: Two-layered marinated toughened glass ( 5mm) motorized front window Negative air pressure provides personnel protection by constant movement of air in working area Remote control operation including front sash movement and fan speed control Motored front window with timer function Digital LCD display for easy monitoring of all parameters Emission of nm for highly efficient decontamination Foot switch to adjust the height of the front window 2 waterproof sockets located in side panel.

14 PASS BOX Pass Box is designed to provide functional support of controlling ingress of particulate contamination in clean room environment as well as in other controlled environment. Further, these pass boxes also allows materials to be efficiently transferred into controlled environment without need of personnel movement. Finding suitability for protecting external environment from egress of contamination, these are perfectly suitable for biological safety laboratory applications. Applications: Used in areas like: Laboratory Semiconductors Space applications Life science Chemical industry Specification: Electromagnetic Interlocking Door. 220V, 50HZ, single phase supply with ON / OFF switch & Indicator. Dust Proof without edges, cracks & pits Provided of 90% down 10 µ efficient, cleanable with compressed air HEPA Filter (mini pleat) provided at the top for vertical laminarity of air housed in S.S. 304 >99.97% down 0.3 µ particle size. Noise Level: Less than 65 db on A scale Air cleanliness: Class 100 Differential pressure gauge, (0-50mm WG) across the Hepa filter Available in mild steel powder coated, SS304/SS 316 Application: Pharmaceutical/ Chemical industry Medical Research lab Space applications Life science

15 STATIC PASS BOX Skylark is customized to allow material to transfer without much personnel movement. It also aids Controlling ingress of particulate contaminants into clean Room between different classified areas. Static Pass Boxes entilated Pass Boxes is widely is used for transferring the material from and into the clean room, without contaminating the air of clean room and without having to open room door. These clean room pass boxes can be installed on the wall between the clean room and other room DYNAMIC PASS BOX Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than % for 0.3μ. Fresh Air Pre-filter are made from Non-Woven Synthetic with HDPE mesh; conforms to EU 6 Grade, with an efficiency rating better than 95% down to 5μ. Dwyer Make Magnehelic Gauge (0-25 mm: 1 Nos.) to monitor pressure drop across HEPA. Internal covings for easy cleaning

16 POSITIVE PRESSURE MODULE Fresh air, from an adjacent area is supplied to the room after HEPA filtration. This air builds a positive pressure in the room when compared to the adjacent area. This pressure gradient prevents ingress of particles through door leaks or when the door is opened Working: The capacity of the positive pressure module be minimum, as along with the air, heat is also added to the room, which calls for increase in AC tonnage Fresh air, from an adjacent area is supplied to the room after HEPA filtration This air builds a positive pressure in the room when compared to the adjacent area This pressure gradient prevents ingress of particles through door leaks or when the door is opened. Working Chamber Size: 3 x2 x2 4 x2 x2 5 x2 x2 6 x2 x2 Optional: High CFM exhaust system (for duct exceeding 10 feet in length) S.S. lining on work bench. PVC fume duct (perft.)

17 AIR CURTAINS We have set a benchmark in the industry for manufacturing and supplying Air Curtain. The offered air curtain is made from high quality materials in our sophisticated production unit. It is used for preventing infiltration of microbes, dust and insects in sterilized cabinets. This curtain finds wide application in the health care centers, pharmaceutical industry and food processing units. Specification: Moc- M.S. CRCA, Powder Coated. Blower / Motor (flame proof)- Make- Crompton Greave -Dynamically balanced and specially Mounted at bottom for low noise & vibrations Limit Switch- Roller type limit switch for switching of air curtain Supply-230V AC, 1 Phase, 50 Hz Dimensional Specification: 1000MM (3 ) 1200MM (4 ) 1500MM (5 ) 1800MM (6 )

18 AIR SHOWER We have set a benchmark in the industry for manufacturing and supplying Air Shower. Air shower is a device which person must pass through before entering clean room/lab in order to contamination. Decontamination is done by clearing of dust and dirt particle. It is used for preventing infiltration of microbes, dust and insects in sterilized cabinets. This curtain finds wide application in the health care centers, pharmaceutical industry and food processing units. Specification: Moc- M.S. CRCA, Powder Coated/SS 304. Blower / Motor (flame proof)- Make- Crompton Greave -Dynamically balanced and specially Mounted at bottom for low noise & vibrations Limit Switch- Roller type limit switch for switching of air curtain Supply-230V AC, 1 Phase, 50 Hz Mini plate box type 0.3HEPA filter, efficiency % down to 0.3micron Particle size, Aluminum Anodized Casing. Dimensional Specification: Features: Clear anodized door stop with seals Drag sweep for bottom door seal Magnetic door interlocking Emergency stop station LED light fixture

19 GARMENT CABINET Garment cabinet can be accumulated contamination during storage and between laundry washes. It is used for maintain cleanliness environment and insects in sterilized cabinets. This garment cabinet finds wide application in the health care centers, pharmaceutical industry and food processing units. Specification: Moc- main body of cabinet is constructed of industrial grade electro galvanized steel/m.s. CRCA, Powder Coated/SS 304. Reliable rocker switches operate the fan and light and magnehelic TM pressure gauge monitor cabinet operation. Blower / Motor (flame proof)- Make- Crompton Greave - Dynamically balanced and specially Mounted at bottom for low noise & vibrations Supply-230V AC, 1 Phase, 50 Hz Mini plate box type 0.3HEPA filter, efficiency % down to 0.3micron Particle size, Aluminum Anodized Casing. Dimensional Specification: Model Name Outside Length Outside Width Outside Height SET SET Features: Provide ISO class 3 air cleanliness within the work zone Enable garment to be stored in a visible and organized manner. Provide controlled environment which lead to better awareness of clean room standardand operating procedure. Enhance filtration system LED light fixture

20 CLEAN ROOM Skylark is design and manufacture clean room typically used for manufacturing and scientific research with a low level environmental pollutant such as dust, aerosol particle, chemical vapors, airborne microbes. Clean room has controlled level of contamination that is specified by number of particle per cubic meter at specified size of particle.these rooms are available from Class 100,000 to Class 10. The rooms are available with open free spans from 6 to 34 feet and interior room heights of 8 to 14 feet. Multiple rooms can be combined to form larger clean room systems. The system allows for additional sections to be added to existing rooms to expand the clean room at a future date. Specification: 50 mm thickness puff panel Clean Room Door make by GI material with Aluminum composite panel 3 mm thickness both side plane HEPA 0.3 micron Aluminum casing box type filter, pre-filter 10 micron Epoxy flooring 2 mm thickness ft with unit) etc MS CRCA powder coated body for blower& HEPA terminal Mini pleat HEPA 0.3 micron Aluminum casing box type filter, pre- filter 10 micron. Cruger make blower motor assembly dynamically balanced blower anti vibration lifting rod Fasnner hard wear 2 TR AC Emerson make Compressor Indoor cooling coil remote operate control panel copper piping(15 ft with unit) etc. Wall Panels and Finishes to comply with any Standard Ceilings, Windows and Doors designed especially for Clean room Use Clean room-specific Lighting, Piping, Ductwork, HVAC, and Fan Filtration Units Clean room electrical Systems and Controls Safety Equipment (Stairs, Handrails, non-slip Flooring) Application: Aerospace: Miscellaneous Applications: Pharmaceutical: Semiconductor: Life Science Features Modular and prefabricated Free-standing; does not become part of the building Can be easily and quickly relocated Large open spans up to 34 ft. Interior clear height 8 to 14 ft. Room Class 100,000 to Class 10 Aesthetic design, visually appealing High quality performance Easy to assemble Expandable and upgradeable Single pass or recirculation Internal room pressure adjustable up to 0.06 in. W.C.

21 MODULAR OPERATION THEATRE Salient Features: To stop the generation of bacteria. To always retain the OT under positive air pressure. Ensure maximum safety standard. Ensure flexibility. Minimize maintenance. Ensure functional separation of spaces. Regulates traffic flow. To prevent noscominal infections. Hygienic atmosphere. Homogenous unidirectional air ceiling system. Product range Modular operation theatre Ceiling mounted laminar flow Operation theatre control panel Surgical scrub stations Storage unit Hatch box Mini scrub station ICU track & curtains Pressure relief dampers Medical gas pipeline systems Sealed clean room light Operating list board OT lights Stainless steel swing door Hermetically sealed sliding doors Vinyl flooring View window

22 CEILING MOUNTED LAMINAR FLOW (PLAN AIR) SYSTEM The ceiling filtration system should be designed to ensure unidirectional distribution of sterile air with differential flow Velocities decreasing from center to perimeter of the surgical theatre to ensure the cleanliness of all the area covered by the airflow. The ceiling system should be equipped with HEPA filters with different performances according to their Position in the ceiling to achieve different flow velocities. The complete filtration ceiling system should be factory assembled its holding structure, filter frames and top plenum should be made of AISI 304 stainless steel.the filtration ceiling system should have flow equalizer to achieve uniform & constant air distribution over the whole Surface it should also have connection for surgical lamp to be fitted in place of any filter. The size of plan air will be 1800mm x 1800mm, 1800mm x 2400mm, 2400mm x 2400mm, 2400mm x 2800mm, 2800mm x 2800mm, as per Theatre size OPERATION THEATRE CONTROL PANEL The surgeon control panel shall meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. The Surgeon s control panel shall be designed to cope with changing technology & equipment in operating environments. Control Panel is user friendly & eases to operate. The panel is Membrane type; configured to incorporate all the services that operation room staff required. The fascia is made of superior quality UV resistance membrane with sterilization feature. Time Day Clock Time Elapse Day Clock General Lighting System Hand Free Telephone set Music control Medical Gas Alarm Panel HEPA Filter Stands Module Room Pressure Indicator Temperature & Humidity Display and/or Control Time day clock shall be digital type & clocks having high brightness characters for better visibility. Time Elapsed Day Clock shall be digital type & clocks having high brightness characters for better visibility Temperature indicator shall indicate the room temperature which shall be connected to the local pressure switches of Air-Conditioning System. Indicators are digital type & clocks having high brightness characters, not less than 30 mm in height.

23 OT LIGHTS Skylark engineering technologies provides the operating lights to meet customer requirement in various configuration with following... Specifications Single and double dome lighting system Light intensity at color temperature of 4500K will be up to Lux. Color Temperature : K Multi reflector to provide shadow less light at all levels. The light head is constructed as to provide optimum conditions for Laminar Flow. Light field adjustments by sterile sable handle. HATCH BOX (PASS BOX) A Hatch Box can be provided in each operation theater to remove waste materials from the operation theater to Dirty linen area just adjacent to Operation Theater. Each Hatch is equipped with two doors and the door shall operate electronically. The Hatch is designed in such a way that only one door should be opened at one time. Modular operation theatre The UV light shall be installed in chamber so that it is kept on while both the doors are closed; this UV light has to be automatically turned off in case of opening of either of the doors. There shall be indicators on both side of the OT so that door open / close status can be monitored from both ends PRESSURE RELIEF DAMPERS Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areas. Counter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room. Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance. The PRD should remain closed at pressure below the set pressure and should open fully at pressure and should open fully at pressure only fractionally above the threshold pressure. The body should be epoxy powder coated as per standard BS colors. First class electrolyzed steel plate should be used for body and with high grade SS304 stainless steel for blades.

24 VINYL FLOORING Vinyl Floorings must meet the needs of healthcare and administrative employees, patients and visitors. Furthermore they need to be long lasting and adapted to the use, they also need to be comfortable and bring a quiet atmosphere to help patient's recovery and relaxation for the elderly. We have created solutions handling these constraints, while still enabling you to customize each area with a wide variety of designs and colors. Concerned about delivering hygiene and disinfection solutions, our floors have stain resistant surface treatments enabling easy cleaning and guaranteed hygiene. While maintaining the technical performance and design of our products. VIEW WINDOW The view window of specified size shall be providing consisting of double insulated fixed glazing with not less that 5 mm thick toughened glass. Window frame shall be powder coated aluminum of approved shape flush mounted with wall paneling. Motorized horizontal venetian blinds of powder coated aluminum strips of approved shade including necessary accessories.

25 HERMETICALLY SEALED SLIDING DOORS To maintain sterility and the correct air pressure in the room, all doors into and out should be of the sliding, hermetically sealing type. The door should meet following specifications: Meets international quality & safety requirements. Doors should be wired to the current IEE regulations & Motor should be DC 24V 70 W brush less DC Motor Noise level of movement should not be more then 60 decibel. Controller should be microprocessor based and be CE marked. Power efficiency should be.95 (in AC 100V full load). The track should be made up of single piece extruded Aluminum. Environment temperature should be -20 C to +55 C. Starting time should be able to regulate from.5 second to 23 second & starting speed should be 600 mm per STAINLESS STEEL SWING DOOR It is a leading manufacturer and supplier of Swing Doors that are available in wide range of shapes, sizes and specifications to meet any requirement of our esteemed clients. The swing doors provided by us are subjected to stringent quality checks during the entire manufacturing and delivery procedure to guarantee premium quality and high performance. The swing doors supplied by us are fabricated from optimum quality steel and are available in single or double panel options. These easy to install, operate and maintain doors have placed us among the luminary Swing doors manufacturers and suppliers.

BioSafety Cabinet- Class 100

BioSafety Cabinet- Class 100 BioSafety Cabinet- Class 100 MODEL NO. - ACM- 42103-L Bio Safety Cabinet Class 100 We are manufacturers of bio safety cabinets class 100 and class 10000 in India since 1990. Our bio safety cabinets are

More information

CLEAN AIR SYSTEM.

CLEAN AIR SYSTEM. AIISHIL" AIR CURTAINS : JCA-01 : Invisible air door, keeps interior of a clean room dust-free, stops entry of insects, serves as temperature barrier and isolates heating, cooling & humidity. Fabricated

More information

Biological Safety Cabinets or Fume Hoods Which one to use?

Biological Safety Cabinets or Fume Hoods Which one to use? Biological Safety Cabinets or Fume Hoods Which one to use? Betty Kupskay, MSc, RBP Biosafety Officer Department of Environmental Health and Safety University of Minnesota Minneapolis, MN kupsk001@umn.edu

More information

LABORATORY CABINETS 103

LABORATORY CABINETS 103 LABORATORY CABINETS 103 MINIFLO DUE - TYPE 60 COMPACT VERTICAL LAMINAR FLOW CABINET DESIGNED FOR MICROBIOLOGICAL AND PCR PROCEDURES A very compact size (footprint 73x61 cm), for small laboratory or dedicated

More information

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class CLASS II, TYPE A BIOLOGICAL SAFETY CABINET SERIES BSC Models: MHE-N300A-PE + PP MHE-N400A-PE + PP MHE-N500A-PE + PP MHE-N600A-PE + PP Optimum protection of personnel, product and environment. BSC Class

More information

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Adv. 8.4 Guidelines for Biosafety Cabinets Rev UNIVERSITY OF CINCINNATI Environmental University Health Services 556-4968 Health and Safety ADVISORY NO. 8.4: GUIDELINES FOR THE SELECTION, INSTALLATION AND USE OF BIOSAFETY CABINETS (INCLUDING ISSUES

More information

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL CLEAN BOOTH JAPAN AIR FILTER CLEAN ROOM EQUIPMENT SERIES Summary

More information

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more. Faster UltraSafe Class II Microbiological Safety Cabinets Protection, safety, reliability. And more. BEYOND MINIMUM SAFETY REQUIREMENTS FASTER UltraSafe ULTRA FEATURES Faster UltraSafe Microbiological

More information

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Faster BH-EN and BHG Class II Microbiological Safety Cabinets Faster BH-EN and BHG Class II Microbiological Safety Cabinets Protection, safety, reliability. And more. APPLICATIONS BH-EN and BHG Class II Microbiological Safety Cabinets have been adopted worldwide

More information

Biological Safety Cabinets. Biological Safety Cabinets

Biological Safety Cabinets. Biological Safety Cabinets Biological Safety Cabinets Biological Safety Cabinets(BSCs) are among the most effective, as well as the most commonly used primary containment devices in laboratories working with infectious agents. Properly

More information

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B. Air Showers The Safety Solution for Animal Research Laboratories Viva Air Shower, Model - EAS-1B. Main Features 2 High velocity shower jets in excess of 20 m/s ensure efficient scrubbing action to remove

More information

L a b o r a t o r y E q u i p m e n t C a t a l o g

L a b o r a t o r y E q u i p m e n t C a t a l o g B y S t a t i t e c h L a b o r a t o r y E q u i p m e n t C a t a l o g Fume Cupboards & Ductless Fume Hoods Biological Safety Cabinets Laminar Flow Clean Benches PCR Cabinets Complete Laboratory Furnishing

More information

Safe Operating Procedure (Revised 2/10)

Safe Operating Procedure (Revised 2/10) Safe Operating Procedure (Revised 2/10) BIOSAFETY CABINETS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Biosafety Cabinet Classification Biological

More information

TRION Air Purification systems

TRION Air Purification systems TRION Air Purification systems TRION Air Boss ATS Purification systems Air Boss ATS There are certain things you expect from an air purification system. A perfect fit for your specific application...effectiveness...

More information

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet Simplifying Your Safety Decisions Now it s easy to select the best biological safety cabinet for your work with gases and

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow General Purpose Laminar Flow Cabinets, Horizontal and Vertical Horizontal Flow 36 48 72 96 Vertical Flow 36 48 72 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets Provides reliable

More information

Innovation in air purification unmatched air quality

Innovation in air purification unmatched air quality Thermo Scientific Ductless Fume Hoods Innovation in air purification unmatched air quality Protects the operator from fume and particle hazards Easy to change filters Improved filter clamping eliminates

More information

DOWNDRAFT BENCH SERIES

DOWNDRAFT BENCH SERIES DOWNDRAFT BENCH SERIES Sentry Air Systems line of Downdraft Benches offers users flexibility, modularity, and durability for the capture and filtration of harmful particles and fume. SERIES INCLUDES INDUSTRIAL

More information

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR Main Features Greater protection against contamination

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification 1. Purpose This specification describes a single person air shower (aka decontamination shower) used to

More information

XPert Balance and Bulk Powder Enclosures

XPert Balance and Bulk Powder Enclosures XPert Balance and Bulk Powder Enclosures Labconco Product Diversity Glove Boxes Fume Hoods Biological Safety Cabinets Freeze Dryers Glassware Washers Filtered Enclosures Carts & Mobile Benches Centrifugal

More information

Fume Hood Safety TYPES OF FUME HOODS

Fume Hood Safety TYPES OF FUME HOODS Fume Hood Safety Fume hoods exhaust toxic, flammable, noxious, or hazardous fumes and vapors by capturing, diluting, and removing these materials. Fume hoods also provide physical protection against fire,

More information

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Biological Safety Cabinets. Presented by Mr. Rene Soetens President Biological Safety Cabinets Presented by Mr. Rene Soetens President Biological Safety Cabinets are referred to by several different names, some of the more common are: BSC, Biosafety Cabinet, Bio-Hood and

More information

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes Page 1 of 5 Title: Biological Safety Cabinet Guidelines Program or Department: Research Document Type: PROCEDURE Effective Date: January 01,2015 Author Steven Hayes Next Review Date: January 01,2016 Reviewing

More information

IVF/ART Series Laminar Flow Cabinets

IVF/ART Series Laminar Flow Cabinets IVF/ART Series Laminar Flow Cabinets Applications IVF/ART procedures for human and animal reproduction require a controlled work environment. Ultra-clean conditions are required to minimise microbial contamination

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods Envair Lab OSN Eco Air H Horizontal Laminar Flow Product Protection Hoods Superior Protection for your Product. 2 These hoods guarantee excellent product protection by offering a clean working area through

More information

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories UL 61010 Viva Dual Access Animal Containment Workstation, Model VDA-4A_ Viva Universal Animal Containment Workstation, Model VA2-4A_E Viva Animal Bedding Disposal Workstation Model VBD-4A_ Animal Containment

More information

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET Laboratory Equipment LAMINAR FLOW CABINETS ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET CLEAN TECHNOLOGY FOR A CLEAN ENVIRONMENT - THE CLEAN GENERATION Envair eco air H cabinets are ISO Class 3 horizontal

More information

BIOLOGICAL SAFETY CABINET

BIOLOGICAL SAFETY CABINET BIOLOGICAL SAFETY CABINET MIT-EHS Biosafety Program - 2014 Learning objectives Learn about different types of laboratory ventilation equipment and their uses in biological research Learn about best practices

More information

Environmental Health and Safety Biological Safety Program Guidance Document

Environmental Health and Safety Biological Safety Program Guidance Document Environmental Health and Safety Biological Safety Program Guidance Document Title: Guidelines for Biological Safety Cabinets Original Date: January 2005 Revised Date: General: This document defines guidelines

More information

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level Clean Air Laminar Flow Ceiling CG 3 Ultra Clean Ventilation System with Unidirectional Flow Draft-free, comfortable room climate Minimal, undisruptive noise level Easy to disinfect housing design with

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

Double Skin Air Handling Units

Double Skin Air Handling Units Double Skin Air Handling Units With Screwless Cabinets Engineered to Deliver High Indoor Air Quality Double Skin Air Handling Units from the Experts Blue Star has over six decades of experience in offering

More information

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: OEM and Industrial Air Handling Specialist DUST COLLECTORS 7697 Snider Road, Mason, OH 45040-9135 Telephone: 513-573-0600 Visit us at www.cincinnatifan.com for more information. Cat. No. DC-108 Supersedes

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS Germicidal UV Technology to Inhibit Microbial Growth and Limit Transfer of Infections in Hospitals UVC can be utilized to inhibit microbial growth and transfer in hospitals through installation in HVAC

More information

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm) aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Cold Energy Saver Thermal Mass Cycling Refrigerated Air Dryers (200-1000

More information

WELD STRONG BREATHE FREE

WELD STRONG BREATHE FREE WELD STRONG BREATHE FREE REVISED 03/01/2017 FUME EXTRACTORS THAT WORK AS HARD AS YOU DO Welding and metal fabricating can be tough, dirty jobs. But they should never be unsafe. Protecting workers from

More information

CIRCULAIRE LAMINAR AIR FLOW

CIRCULAIRE LAMINAR AIR FLOW CIRCULAIRE LAMINAR AIR FLOW Including Visionaire Touchscreen British Design & Manufacture THE MARKET LEADER IN CLEAN AIR SOLUTIONS +44(0)1278 458090 How Does Laminar Flow Work? LAMINAR FLOW AIR FILTRATION

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

Supplying Clean Air to Industry

Supplying Clean Air to Industry Next Generation MistBuster : 500, 500 Media, 850, 2000, Infinity Supplying Clean Air to Industry The MistBuster family of self-contained mist removal systems is designed to capture mist and smoke from

More information

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories Airstream Class II Type B2 (Total Exhaust) Biological Safety Cabinet, Model AB2-4S_. Shown with optional support stand. Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution

More information

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai Guidelines for Ideal Layout for an Operating Theater Complex Dr.R.D.Ravindran Aravind Eye Hospital Madurai Patient Flow 1. WARD 4. RECOVERY ROOM 2. BLOCK ROOM 3. THEATRE Transfer area This is an area,

More information

Air Micron, a 5 year old venture, in the field of integrated micro contamination control, specializes in:

Air Micron, a 5 year old venture, in the field of integrated micro contamination control, specializes in: 1) About us : AIR MICRON CLEANTECH is one of the leading Pre-engineered, Prefabricated Air Handling Unit, Ventilation and clean room equipment manufacturer in India. AIR MICRON CLEANTECH has an expert

More information

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment: ...Only from Eriez FB-200B Tramp Oil Removal Equipment: Oil Skimmer Oil Skimmer Jr. Coalescer Tank-Side Coalescer Portable Coalescer Portable Jr. Centrifuge Portable ERIEZ Tramp Oil Removal Equipment Equipment

More information

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain An ISO 9001 Certified Company CLEAN AIR SYSTEMS DIVISION Nan Technical Trading W.L.L P.O.Box - 2683 Manama Kingdom of Bahrain Tel: +973-17212023 Fax: +973-17212289 Email: nan@nantechgroup.com Website:

More information

Kitchen Exhaust Air Cleaning Systems

Kitchen Exhaust Air Cleaning Systems Kitchen Exhaust Air Cleaning Systems Air Quality Engineering, founded in 1973, is proud to offer a continued, superior level of experience in manufacturing complete air filtration systems that provide

More information

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Certified for shock and electrical fire hazard only. MAJOR COMPONENTS

More information

Cleanroom Air Showers

Cleanroom Air Showers Technology of Tomorrow Cleanroom Air Showers KYODO-ALLIED TECHNOLOGY PTE LTD 17 Kian Teck Road, Singapore 628771 Tel: (65) 6265 1311 Fax: (65) 6265 8100 Website: www.kyodo.com.sg The biggest contaminant

More information

Laboratory Automation & Robotic System Enclosures

Laboratory Automation & Robotic System Enclosures LA Product Range Laboratory Automation & Robotic System Enclosures A World Class Manufacturer of Enclosures Innovative Solutions for Advancing your Research Bigneat manufacturing a smarter range of enclosures

More information

Sentry Air Systems, Inc.

Sentry Air Systems, Inc. Sentry Air Systems, Inc. Plastic Fume Extraction Systems Simple Solutions for Cleaner Air. Made in U.S.A. 800.799.4609 www.sentryair.com sales@sentryair.com Hazards of Plastic Fume FUME & PARTICULATE REMOVAL

More information

INCREASE YOUR LAB EFFICIENCY

INCREASE YOUR LAB EFFICIENCY INCREASE YOUR LAB EFFICIENCY Mars Pro Class 2 Ultra-Safe Triple Filters Microbiological Safety Cabinets Scandinavian by Design Mars Pro, the ideal choice for your laboratory, wherever personal, environment,

More information

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of the University of Texas at Austin for safety equipment used in or in support of

More information

Quick Reference Guide to Cabinet types

Quick Reference Guide to Cabinet types Quick Reference Guide to Cabinet types The following notes are designed as a guide to the different types of cabinets used in Laboratories, Pharmacies, Universities or Industry. They may be used as a guide,

More information

TYPICAL CPA SPECIFICATIONS

TYPICAL CPA SPECIFICATIONS TYPICAL CPA SPECIFICATIONS 4/10/2017 UNIT CONSTRUCTION: Casing: The exterior casing of the unit shall be constructed of 18-gauge, G235 galvanized steel (optional stainless steel or aluminum), unpainted.

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

LAMINAR FLOW FOR ALL YOUR NEEDS

LAMINAR FLOW FOR ALL YOUR NEEDS LAMINAR FLOW FOR ALL YOUR NEEDS 2 LAMINAR FLOW FOR ALL YOUR NEEDS EXPLORE TECNIPLAST COMPLETE RANGE OF LAMINAR FLOW SOLUTIONS: OUR CUTTING-EDGE TECNOLOGY IS AT YOUR SERVICE, TO ASSURE TOP ENVIRONMENTAL,

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

VP, Facilities and Construction Management

VP, Facilities and Construction Management Title: Biological Safety Cabinets Procedure Effective Date: November 2005 Revision Date: February 24, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director Environmental

More information

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets Table of Contents Laboratory Fume Hoods Page UniFlow Fume Hood Systems UniFlow SE Fume Hoods...4-5 UniFlow Conventional / VAV Fume Hoods...6-7 UniFlow Auxiliary Air Fume Hoods...8-9 UniFlow LE Fume Hoods...10-11

More information

VAC-U-DRY VACUUM DEHYDRATOR

VAC-U-DRY VACUUM DEHYDRATOR VAC-U-DRY VACUUM DEHYDRATOR Remove Free & Dissolved Water down to 20 PPM (0.002%) Flow range 5~60 gpm,19~225 lpm Visually Monitor Fluid and Process through Clear Chamber Covers High Operating Vacuum and

More information

DRYAIR Turnkey Dry Room Standards

DRYAIR Turnkey Dry Room Standards DRYAIR Turnkey Dry Room Standards Manufacturers of moisture sensitive or hygroscopic products can realize substantial productivity and quality increases, along with greatly reduced energy consumption by

More information

CBC s Inspection Findings and Possible Remedies Thereto

CBC s Inspection Findings and Possible Remedies Thereto CBC s Inspection Findings and Possible Remedies Thereto Contents of this Presentation This presentation contains examples for findings which CBC has identified during the inspection of GMP / biosafety

More information

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream.

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream. AIR KNIFE SYSTEMS PRODUCT OVERVIEW REPUBLIC AIR KNIFE SYSTEMS are engineered, manufactured and tested to provide 99.9% of liquid, dust, and debris removal from products prior to labeling, ink jet laser

More information

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304) Biosafety Cabinets and Fume Hoods Introduction Welcome to the Biosafety Cabinets and Fume Hoods Training for OHS_BIO304. This information is for anyone that will be conducting work and/or research that

More information

Modular Room System For Operating Theathres

Modular Room System For Operating Theathres Modular Room System For Operating Theathres Modular Room System For Operating Theatres Nowe zdjęcie We ensure complex realization of projects for modular operating theaters and other hospital rooms. Our

More information

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com LabGard NU-602 Biological Safety Cabinet

More information

Technical Catalog laboratory furniture system

Technical Catalog laboratory furniture system Technical Catalog laboratory furniture system Technical Catalog The new design of our SCALA laboratory furniture program is creating the laboratory of the future. Only when design and functionality effectively

More information

AIR SHOWERS CAP701 SERIES

AIR SHOWERS CAP701 SERIES AIR SHOWERS CAP701 SERIES CAP701 KD-ST CAP701 LP-ST CAP701 tunnel Durable heavy-gauge painted steel construction Inspection panels for high-pressure supply ducts Highest velocity and air volume rate for

More information

Technical Specifications & Pricing

Technical Specifications & Pricing Nu/Clean Model 510 Recirculating Water Deionizer Inline Aqueous Cleaning System for Closed Loop, Zero Discharge Operations Technical Specifications & Pricing The base machine in its standard configuration

More information

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science LaboGene SCANdinavian by design. ORION ALMOST Rocket Science Safety Class 2 100% exhaust Probably the best Class 2 with 100% exhaust for work with animal handling or high concentrations of organic solvents

More information

MODEL NUMBER NOMENCLATURE

MODEL NUMBER NOMENCLATURE MODEL NUMBER NOMENCLATURE DS 2200 BT P XXX OPTIONS: (SEE LIST BELOW) CONSTRUCTION: P - High Density Polyethylene FRP - Fiberglass CONFIGURATION: BT (Blow through) DT (Draw through) PA (Passive) CFM MODEL:

More information

5.0 Installation Instructions

5.0 Installation Instructions 5.0 Installation Instructions 5.1 Location Within the laboratory, pharmacy, etc., the ideal location of the biological safety cabinet is away from personnel traffic lanes, air vents (in or out), doors

More information

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities Pulse Jet ASTEC PULSE JET BAGHOUSE for Asphalt Facilities ASTEC PULSE JET BAGHOUSE FOR ASPHALT MIXING PLANTS Astec baghouses deliver superior performance and efficiency, while helping your plant meet

More information

ELECTROSTATIC FILTER 1000

ELECTROSTATIC FILTER 1000 EDIA FILTER MF1000 ELECTROSTATIC FILTER 1000 ELECTROSTATIC FILTER 1000 The acs 1000 is designed for direct attachment to most machines and machining centres. Isolator Isolator for start/stop and mains

More information

Double Skin Casing Air Handling Units

Double Skin Casing Air Handling Units Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate

More information

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI Animal Tissue Culture SQG 3242 Equipment and Lab design Dr. SITI PAULIENA MOHD BOHARI Sign Symbol? Biohazard sign Means? Hazardous For labeling the biological materials that carry a significant health

More information

Submittal Data Performance Data Electrical Data

Submittal Data Performance Data Electrical Data ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:

More information

Laminar Flow Cabinets eco air V

Laminar Flow Cabinets eco air V Laminar Flow Cabinets eco air V Class ISO 3 Vertical product protection cabinet Standard EN ISO 14644-1 Breite (m) 0.6 / 0.9 / 1.2 1.5 / 1.8 Clean technology for a clean environment eco air V the clean

More information

Packed With Features. Smart Pulsar controls are conveniently

Packed With Features. Smart Pulsar controls are conveniently Packed With Features Filter cartridge is automatically cleaned each time the pedal is operated. Pull-through exhaust fan reduces wear on impeller blades. Unique Air Logic System maximizes air flow to the

More information

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station AES Environmental Operation and maintenance manual VWS Series Laminar Vertical Flow clean work station Contents 1. INTRODUCTION... 3 2. APPLICATIONS AND LIMITATIONS... 4 2.1 Applications:... 4 2.2 Limitations:...

More information

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE

WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE WATER WASH BOOTHS PUMP TYPE PUMPLESS TYPE Highest Quality Finish and Environmentally Safe The Spray Systems Water wash Spray Booth provides an extremely efficient means for removing paint particles from

More information

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation Air handling units KLASIK Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation KLASIK air handling units Customer oriented and unique

More information

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated. Packed With Features Filter cartridge is automatically cleaned each time the pedal is operated. Pull-through exhaust fan reduces wear on impeller blades. Unique Air Logic System maximizes air flow to the

More information

Biological Safety Cabinet

Biological Safety Cabinet Biological Safety Cabinet (Class I & Class II Type A2/B2, Class III) Senova Labtech (Shanghai) Co., Ltd. Class I Biological Safety Cabinet The Class I biological safety cabinet is an open-front negative

More information

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS DUST COLLECTORS & DOWNDRAFT TABLES A division of SOLUTIONS BELT-DRIVEN RSC/RSO RSC/RSO blowers are typically installed before the dust collector and are used for the transportation of materials. They develop

More information

PART III. Laboratory equipment

PART III. Laboratory equipment PART III Laboratory equipment 10. Biological safety cabinets Biological safety cabinets (BSCs) are designed to protect the operator, the laboratory environment and work materials from exposure to infectious

More information

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

General Purpose Laminar Flow Cabinets, Horizontal and Vertical 24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a multitude of applications. p:2 Product

More information

HALCO PRODUCTS COMPANY

HALCO PRODUCTS COMPANY AIR SHOWER AND AIR SHOWER TUNNELS 9/3/2010 STANDARDS AND QUALIFICATIONS AIR SHOWERS- ARE THEY WORTH THE COST? DO THEY REALLY REDUCE CONTAMINATION? CAN THEY BE COST JUSTIFIED? The efficacy of air showers

More information

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results Automatic Cyanoacrylate Fuming Chamber The World s Most Advanced Cyanoacrylate Fuming Chamber. 24 33T 60T 72XL Safefume 360 ARV-33T Chamber shown with optional UV Lamp and UPS Safely Detect Quality Latent

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES BRAHM COLLECTOR SERIES Working together for a crystal-clean production line #1 in Welding Smoke, Oil Mist & Oil Smoke Removal Best in Class for Innovative Products and Services SERIES BRAHM by CLEAN AIR

More information

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option. Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally

More information

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR EQUIPMENTS /INSTRUMENTS HORIZONTAL LAF BENCH VERTICAL LAF BENCH FAN FILTER UNIT AIR SHOWER GARMENT CUBICLE DISPENSING BOOTH/SAMPLING BOOTH STATIC PASS

More information

Aero Biotechniques.

Aero Biotechniques. +91-8048576262 Aero Biotechniques https://www.aerobiotechniques.com/ We are Manufacturer and Supplier of premium quality Clean room Validation Services and Equipment. Our extensive product range is known

More information

Gelaire BH-EN and UltraSafe cabinets

Gelaire BH-EN and UltraSafe cabinets BH-EN and UltraSafe Class II biological safety cabinets Personnel, environment and product protection Compliance, protection, reliability. And more. Gelaire BH-EN and APPLICATIONS Gelaire BH-EN and UltraSafe

More information