Automated Electric Brewing System

Size: px
Start display at page:

Download "Automated Electric Brewing System"

Transcription

1 Automated Electric Brewing System Operation Manual V2.07 (For Brew-Boss App Versions 1.27 and later) Page 1

2 1 - System Overview The Brew-Boss home brew system is an all electric home brewing system that allows home brewers to brew extract and all-grain recipes with complete and accurate automatic control of temperature and timing. Complete systems are available in 10, 15, and 20 gallon versions in both 120VAC and 240VAC options. The 10 gallon version produces a 5 gallon net batch, the 15 gallon version is capable of 10 gallon net batches, and the 20 gallon system is capable of 5, 10 and 15 gallon batches. The Brew-Boss System utilizes a power control box that controls one or two electric heater elements, a recirculation pump, and an optional Hops Boss automatic hops feeder. The Brew-Boss controller communicates with an Android Tablet App that provides a color touch screen graphical user interface that allows complete control over the brewing process. All steps and parameters relative to the brewing process can be modified by the user to control nearly any brew setup. It operates in a completely Automatic mode, or can be operated in manual step mode for those that want manual control over their brewing process. The base system provided operates as a Brew-in-a-Bag system with a single kettle. A version is also available with a COFI Mash Infusion Filter that replaces the mesh bag in a BIAB system and offers a few additional advantages. The controller will also control 2 and 3 vessel systems as well! The Brew-Boss controller interfaces with the Android tablet or ipad via a Wi-Fi interface. The Brew-Boss controller can be purchased as a part of a complete system or the controller can be Page 2

3 purchased separately to add to your existing system. Brew-Boss system can be supplied as a Brew-In-A-Bag (BIAB) or with our patented COFI mash infusion system. Complete systems include the following components: 10, 15, or 20 Gallon Stainless Steel Kettle with Petcock Valve and Side Mounted Recirculation Accessory Port 3500 or 5500 Watt Electric Heating Element for 240 Volt Systems or Dual 1500 Watt Elements for 120VAC 10 Gallon Version Microprocessor Controlled Brew-Boss Brew Controller with LCD Display and Integrated WiFi Router High Temperature Recirculation Pump Recirculation System with Camlock quick connect fittings and Brewery Grade Hoses (Silicone not Vinyl) Infusion System. Either the COFI Mash Infusion Basket or BIAB with a false bottom and mesh bag. Side Mounted Sparge Sprayer for BIAB version Electronic Temperature Sensor Probe Optional 7 or 10.1 Android Tablet with Brew-Boss Software Note: This system is sold as a complete kit with the exception of the Power Plug. You will need to add a 240VAC power plug that corresponds to your local electrical requirements and your 240VAC receptacle. A 30 AMP circuit is required. A Ground Fault Interrupter is highly recommended as well for this circuit. For the 120VAC system, all plugs and receptacles are provided. The customer must make certain that they are plugging the two power cords into two separate 120VAC outlets that are on DIFFERENT CIRCUITS in their home. VERY IMPORTANT!! Test the System with a Wet Run with only Water Read the entire document before attempting to brew with the system and potentially waste good ingredients. The vast majority of tech support requests and issues we hear about are clearly described in this document, but were never read. Read the entire document so you fully understand how the system operates, then, do a Wet Run with only water for the entire brew process. You can use the WetRun Brew Definition file included with the application to test the entire system in a shortened amount of time. Please do the Wet Run before trying an actual batch. Page 3

4 2 - Brew-Boss Controller & Android Tablet The Brew-Boss controller contains all of the necessary control elements to allow automated control of the brewing process. A small embedded controller (Arduino) with a purpose built control circuit board are the heart of the controller. The controller accepts input from a plug-in digital temperature probe and controls the heater and the pump via industrial quality Solid State Relays (SSR's). A wi-fi interface is also provided for the Hops Boss Automatic Hops Feeder. A 12-digit numeric LCD display is provided to allow viewing of the temperature, power setting and the pump state (0=Off and 1=On). The controller itself will do nothing without instructions from the Brew-Boss application running on an Android Tablet or ipad (Tablet). The controller simply receives commands from the tablet and provides status information back to the application, but does not actually control the brew process on its own. Before brewing, you must install the Brew-Boss application on your tablet. Make sure you have created a Google (Android) or itunes (ipad) account on your tablet and that you are connected to a Wi- Fi network with internet connection. Open the App store. In the applications area, search for Brew- Boss. The Brew-Boss application should be found in the search results. Install the application, but do not run it yet, as you must first connect to the Brew-Boss controller. The controller connects to the Tablet via a Wi-Fi interface. To connect via Wi-Fi, it is required that you first connect to the Brew-Boss network using the tablet's wi-fi settings before connecting to the controller, where Brew-Boss is the SSID of the wi-fi controller. The Brew-Boss controller must be powered on for at least 1 minute for the Wi-Fi radio to start up. Please note, that the Brew-Boss controller acts as it's own server, and that you will not be able to communicate with the internet or your home/work network on the tablet while connected to the controller. It is recommended that before you Page 4

5 run the Brew-Boss application that you forget the network you connect to the internet with. This is because the tablet will try and connect to the strongest powered network with internet access automatically, and should the signal strength of the Brew-Boss network drop, the tablet will automatically try and connect to other stronger wifi networks. So all other networks other than the Brew-Boss network should be Forgotten prior to running the Brew-Boss application. To forget a network, simply touch the network SSID in the tablet's wifi settings and select the Forget or remove option. Once you have connected to the Brew-Boss controller, run the Brew-Boss application. The app screen shows the status of the connection to the Brew-Boss controller in the upper right hand corner of the screen. If you have connected successfully, the Status Bar should turn green and display Connected as indicated in the picture below. You can test the connection by selecting the menu, other, test alarm. The alarm inside the controller should sound indicating the tablet is communicating. 3 - System Setup Select a Location Select a location for your system. The ideal location is within access to a 30 AMP 240VAC power panel or outlet (Stove, Dryer, Welder, etc.) for the 240VAC system or within proximity to two separate Page 5

6 120VAC receptacles on different circuits for the 120 volt systems. It should ideally have a ventilation system that removes steam vapors and sends them outside. This could be a range hood, etc. You should have a sturdy work surface such as a counter top, work bench, or table. Basements and garages are ideal. If you brew outdoors, avoid windy areas or cold temperatures below 50 degrees F. The wind and/or cold temperatures can greatly affect the ability of the system to maintain temperatures. Ideally, some type of overhead support such as a floor truss, ceiling truss, etc. for mounting a lifting device above the kettle is helpful as well. For the COFI version, this is required. Brew-Boss offers a very nice block and tackle type hoist on the brew-boss.com web site. Access to a water supply and sink for cleanup nearby is essential. Brew-Boss Controller Connections Page 6

7 Wiring/Power According to the web site: It is recommended that GFCIs be installed in areas where appliances and power tools are used in close proximity to water The Brew-Boss system is designed to be as electrically safe as possible considering the fact that it is being used to heat water and pump water and several amps are involved. To facilitate the use of GFI breakers and outlets, the various circuit elements must be separately powered. As such, there are separate power plugs for the 240VAC and 120VAC required by the system. After receiving your system, you will need to facilitate powering the unit with VAC and/or 120VAC. The 240VAC system requires a 30 AMP VAC circuit and a 15 or 20 AMP 120VAC circuit. The 120VAC system requires two separate 15AMP circuits VAC Circuit This circuit drives the heater on USA systems and also the pump for systems supplied outside the USA. The Brew-Boss controller is equipped with a 15 foot long 240 volt power cord terminated with an L6-30P twist lock plug that is molded onto the cord. It is recommended that you install an L6-30R receptacle on the GFI circuit you will be running the Brew-Boss syustem on. If you do not have an L6-30R receptacle and want to use an existing dryer or range outlet, you can simply cut the molded L6-30P plug off of the cord and install a plug that matches your outlet (obtain from local home supply or hardware store). The power cable from the controller has three (3) wires, Black, White, and Green. The White and Black wires get wired to the HOT prongs of your plug (L1 and L2). The GREEN wire gets wired to the GROUND prong of your power plug. If you have a 4-wire receptacle, simply do not use the 4 th prong, which is the Neutral wire. 120 VAC Circuit For the 240VAC system, plug the 3 prong 120VAC plug into a 120VAC outlet. It is recommended that this outlet be a GFI type as well. This circuit drives the water pump. For the 120VAC system with dual 1500Watt heater elements, you must locate two 120VAC outlets in your home that are on different circuits, and route the two power cords to those outlets. It is recommended that these outlets be GFI type as well. Separate circuits means that they are serviced by different breakers in your main breaker panel. If you are unfamiliar with this nomenclature, find someone that understands it or even an electrician to help you locate acceptable outlets. Page 7

8 Warning - Shock Hazard! Brew-Boss V2.07 Operation Manual This is an all electric system. It eliminates the many dangers associated with gas fired systems, but working with electricity is dangerous. You can be seriously injured or worse die by electricity. This system requires that you provide a 240VAC 30 AMP or two 120VAC 15 Amp circuits and the appropriate power plug. A ground fault interrupter circuit breaker is highly recommended! If you are not comfortable or not knowledgeable with electrical wiring please have a certified electrician wire your system. *** By ordering this product, you accept all liabilities for any and all damages that may occur by your usage of this equipment. Further you agree to install all equipment in accordance with your local codes and regulations as required. *** Place Kettle on Work Surface Place the kettle on a surface that can handle high temperatures. We recommend using silicone trivets as they prevent thermal losses to the surface and prevent slipping as they are fairly sticky so they keep the kettle from sliding around. The picture shows the type we are suggesting. Position 3 or 4 of them in a pattern that assures the kettle is completely supported. Page 8

9 Install the Heater Element Assembly The Brew-Boss heater element assembly is a Tri-Clamp device and needs to be clamped to the Tri- Clamp ferrule(s) on the lower left side of the kettle using a Tri-Clamp clamp. Install the Red silicone gasket between the heater and the ferrule on the kettle. Make certain the gasket is centered in the grooves and does not get pinched while installing the clamp and tightening. Hand tighten the clamp, do not use tools to tighten the clamp. For 240 Volt 10 gallon systems, install the cap on the spare ferrule as there is only one heater. For 120 volt systems, install both heater assemblies as described above. Brew-Boss Heater Element Assembly Brew-Boss Heater Element Assembly Installed in Kettle Page 9

10 Insert the Digital Temperature Probe The temperature probe plugs into the controller using a headphone type stereo plug on the right side of the controller. The system includes a weldless temperature probe coupler that allows direct contact between the sensor and the water. This provides faster and more accurate temperature control. Install the weldless temperature probe coupler to the 1/2 diameter hole in the kettle as shown in the drawing below. Care must be taken to properly install the temperature sensor. Fist, install the nut and two rubber O- rings as shown in the picture. Next, insert the assembly into the coupling on the kettle as shown so that about ¾ 1 inch protrudes into the inside of the kettle. Make certain it will not interfere with the COFI infusion filter if you are using that device. Apply a very small amount of petroleum jelly to the O-rings for lubrication. Page 10

11 kettle while clearing the COFI filter or false bottom. Tighten the nut by hand (never use a wrench) until it is just tight enough to prevent it from coming off on it's own. If it leaks, tighten a little more. Over tightening will damage the O-rings, so be careful and lean towards too loose rather than too tight. It is very important here to make certain the sensor is not touching any metal of the weldless fitting. If it touches metal, it will measure the temperature of the kettle rather than the liquid (water or wort) in it. The probe should be insulated by the two o-rings and rest centered in the hole when viewed from the inside. It should protrude as far as possible into the If you are seeing readings 5-7 degrees F below actual, you probably have not installed the probe properly. The sensors supplied with this system are digital and are certified accurate within 1 degree C. If your system uses a thermowell type temperature sensor housing, simply insert the temperature probe into the thermowell tube as far as you can get it in so that it bottoms out. The temperature sensor works best when it is in direct metal to metal contact with the thermowell. It is suggested that thermal grease or paste be applied to the sensor before it is inserted to improve thermal conduction and thus the response of the sensor. These thermal products are commonly used to mount heat sinks to computer processors, etc. and are readily available on the internet or at Radio Shack. Install Recirculation Plumbing Components The system includes several stainless steel threaded fittings. It is important to wrap all threads with a high quality Teflon thread tape. We like Blue Monster PTFE tape. Wrap all male threads in the steps below with 4-6 layers (about inches) of tape prior to assembling all connections. Wrap in the direction shown in the picture so that when threading the fitting on the tape is forced to wrap onto the thread rather than removed. Page 11

12 Install Accessory Port Install the accessory port to the hole on the front top of the kettle. There are two types of accessory ports, VALUE and DELUXE. The VALUE accessory port has a Camlock nipple on the inside of the kettle and a barbed nipple on the outside of the kettle. VALUE Accessory Port Assembly The DELUXE accessory port has a Camlock nipple on the inside and outside of the kettle. DELUXE Accessory Port Assembly Page 12

13 For both accessory port styles, the Camlock fitting shown on the left of both images above is installed inside the kettle. To install the accessory port, first wrap the threads of the male threaded Camlock nipple with Teflon tape as described above. Then, install the thin stainless steel washer over the wrapped threads. Now install the high temperature gasket over the threads being careful not disturb the Teflon wrap. The nipple will look like the following picture when properly assembled. Inside Accessory Port Camlock with Teflon Tape, Washer, and Gasket Installed Next, carefully push the inside accessory port Camlock nipple through the hole on the top of the kettle from the inside, being careful not to disturb the Teflon wrap. If a second Stainless Steel thin washer was provided, install that over the threads from the outside. Now, thread the female nipple onto the wrapped threads. Using two wrenches, tighten the two nipples together until the gasket just begins to compress visually. The accessory port can remain installed and typically does not need to be removed. Just make certain when cleaning, to run a small round brush through the hole to remove any trapped debris. Install Kettle Valve Install the valve to the Tri-Clamp to male pipe adapter assuring that the handle will rotate outwards (away from the kettle) when installed to the kettle. Install the Male Camlock (DELUXE System) or hose nipple (VALUE System) to the exit side of the valve. Use a Teflon tape on the threaded joints as described earlier. Kettle Valve Assembly (shown with DELUXE Camlock nipple) Page 13

14 Install the valve assembly to the Tri-Clamp ferrule on the bottom front of the kettle (below the Brew- Boss Logo) using the clear silicone gasket between the valve and the ferrule on the kettle. Make certain the gasket is centered in the grooves and does not get pinched while installing the clamp and tightening. Hands tighten the clamp; do not use tools to tighten the clamp. Kettle Valve Assembly Installed on Kettle (shown with VALUE nipple) Option: Install Lifting Device Wet saturated grains can get very heavy (each 9 lbs of grain absorbs about 1 gallon of water) and when they are hot, can be difficult to work with. When removing the wet grains, it is desirable to let the grains hang above the kettle for a while to allow the trapped wort in the grains to drain into the kettle. If you are using the BIAB mesh bag style system, you'll need a lifting device like the one shown below. Simply tie the end around the BIAB bag with a slip knot. These locking lifts are nice as they self lock as you pull them up, so the bag won't drop uncontrolled if you accidentally let go of the rope. We offer Page 14

15 these on our web site as well. Brew-Boss V2.07 Operation Manual Self Locking Lifting Device (Available on Brew-Boss Web Site) We recommend mounting an eye hook above the kettle to the ceiling, truss, joist, etc. so this can be utilized. If you are using the COFI mash infusion filter, we recommend the rope lifting device above, but an electric hoist is much better! This is what we use. It is a 440 pound capacity hoist and we got ours from Harbor Freight for $100. When using this, be careful not to hook your COFI filter on the heating element or the temperature probe. It has a lot of power and can do damage quickly. Add Water to Kettle To validate everything is working and that there are no leaks, we need to add water to the kettle. First, making sure the valve is closed, add enough water so that the water level is just above the temperature sensor. Check for leaks around the heater element, faucet, and temperature sensor. Make certain gaskets are positioned properly if you have any leaks. Note: Never never never ever power the system without enough water in the kettle to cover the heating element! The element is designed to be submersed and if powered on without being in water can burn out very quickly. We do not warrant the heating elements for this reason. Page 15

16 Connect Heating Element to the Controller The heating element simply plugs into the controller using the L6-30 twist lock connectors. Make sure that the controller is NOT plugged into the 120 or 240VAC source and the switch on the front of the controller is in the OFF position. It is possible that one could touch one of the metal prongs while plugging the two connectors together, so make sure the POWER IS OFF! This plug is provided to make it easy to detach the kettle from the controller so the kettle can be cleaned. Make sure to always POWER OFF the controller and unplug the controller from the 120 and/or 240VAC source when unplugging or plugging in the heating element assembly/assemblies. The heater element should be plugged into the controller before the controller is powered up. Care should be taken when removing the cord from the heating element to assure that the twist lock is released by turning counter clockwise before pulling. The cord should come off easily, do not force the cord off or damage could result to the prongs on the heater element. Turn the Master Switch On To turn the master switch on the front of the controller on, move the red lever switch on the front of the controller to the ON position. You can use this switch as an emergency stop switch for the heater if for some reason you need to turn the heater off quickly, like when you inadvertently turn the heater on without water! Upon power-up, the LCD on the controller will display a start-up message B-BOSS X-X where the X-X is the version number of the firmware installed. If you forgot to plug in the temperature probe, the controller will beep and warn you that no temperature probe was detected. The Wi-Fi radio in the controller takes seconds to start up. Wait at least this time before trying to connect to it with the tablet. Page 16

17 Start the Brew-Boss Application After the controller is powered up as described above, make sure you are connected to the Brew-Boss network as described in Section 2. After connecting to the Brew-Boss network, you can start the Brew-Boss app on the Tablet. The Brew-Boss App attempts to connect to the controller automatically on start up. The Controller Connection Status window at the top right side of the screen should turn Green and indicate Connected as shown in the following picture. Make certain that your system parameters are set up properly as described in Section 6 in this manual. The temperature shown on the controller LCD should match that shown on the Brew-Boss App. Once successfully connected, you can proceed to testing the heater, pump, and Hops Boss hops feeder if you have one. Test the Heater Test the heater by pressing the Heater Toggle button so that the little green indicator turns on as shown. The heater power slider bar should change to 100% and the heater power on the LCD display on the controller should change from 0 to 100. Page 17

18 Look at the heater element, you should see small bubbles coming off the heater element and most of the time, hear it heating as well. If it appears the heater is not functioning, confirm that the heater is plugged into the controller. Now try dragging the yellow heater power slider to the left with your finger. You should see the power setting change. Let up on the bar and you should see the corresponding power setting on the LCD display on the controller. Install the Pump The pump is marked with the direction of flow through the pump housing. Water flow is from the kettle valve, through the pump, and then to the accessory port on the kettle. Install the stainless steel flow restriction valve on the discharge side of the pump. Use a high quality Teflon plumbers tape on all threaded joints. Next, install the MALE stainless steel barbed or Camlock fittings onto the inlet of the pump and outlet port of the flow restriction valve. Do not over tighten, especially on the plastic body pump. Page 18

19 Flow Restriction Valve and Nipples Installed on Pump (DELUXE fittings shown on Stainless Pump) The Brew-Boss system is supplied with either barbed (VALUE) or Camlock (DELUXE) type quick connect/disconnect fittings. If you purchased the VALUE system, the silicone brewery hose simply slips over the barbed nipples on the fittings. No hose clamps are required on the input side of the pump as there is no pressure inside those hoses. Use the supplied hose clamps for the hoses on the discharge side of the pump. The Brew-Boss system includes 6 feet of silicon brewery grade tubing. You need to cut this tubing into two pieces based on your desired setup. We recommend 2 feet between kettle and pump and 4 feet between pump and kettle, but let you cut it as you desire. If you are using Camlock fittings, you will need to attach the female camlocks to each of the 4 ends of the tubing you cut. If the Camlocks provided have differing size nipples, use the nipples with the larger diameter on the pump inlet side. DELUXE Recirculation Plumbing Hardware Configuration Note: According to Chugger Pump, the pump should never be run full flow on the discharge. There should always be some back pressure on the discharge of the pump otherwise the pump could de-couple and stop pumping. For this reason, always close the flow restriction valve on the discharge side of the pump slightly to create some back pressure. Of course during mashing, you adjust the flow restriction valve on the discharge side of the pump to maintain the proper liquid level in the kettle. With BIAB systems using false bottoms, make certain to stir your grains often to prevent he pump from creating a vacuum beneath the false bottom, potentially damaging your kettle or false bottom! Page 19

20 DELUXE Recirculation Plumbing Hardware Installed The pump should be located on the same level as the kettle or below the kettle so that at least 12 of water are above the pump. Connect all the tube ends to the appropriate points as shown in the images above. The two hose clamps supplied are intended to be installed on hose on the discharge side of the pump, as that is the high pressure side. No hose clamps are needed on the hose that goes from the kettle valve to the pump. Test the Pump Plug the pump into the pigtail 120 VAC receptacle on the back of the controller. If you purchased the 240 volt pump, you will need to install mating electrical plugs (female on controller and male on pump) that match your local standards. Now open the valve and wait for a few seconds for the water to flow into the pump. The pump should never be run dry, so make sure the valve is open and water has filled the tubing to the pump. The pump can be screwed down to the work surface or placed on a silicone trivet to keep it from sliding around and to silence vibrations. Warning: Never try and run the pump without water in the kettle and the valve on the kettle open. Running the pump dry can damage it. If you want to test the output, you can plug an electric lamp or Page 20

21 other electric device that requires less than 10 amps into the pump pigtail receptacle. To test the pump, simply press the Pump Toggle button on the App so the prompt changes from Pump Off to Pump On and the little green light on the button lights up. The pump should turn on and begin circulating water (make sure the discharge hose is connected to the accessory port!) By the way, the toggle pump button is a handy Emergency Stop button for the pump any time you need to turn it off. Once pump operation is validated, repeat the steps above to toggle the pump off. Test the Alarm An alarm is provided to alert you when your interaction with the system is required. To test the alarm, enter the menu on the tablet and select the More entry then the Test Alarm entry. This will allow you to validate the volume is set appropriately for your brew environment as well as validate the alarm in the controller is operational. VERY IMPORTANT!! Test the System with a Wet Run with only Water Read the entire document before attempting to brew with the system and potentially waste good ingredients. 90% of tech support requests and issues we hear about are clearly described in this document, but were never read. Read the entire document so you fully understand how the system operates, then, do a Wet Run with only water for the entire brew process. You can use the Wet Run Brew Definition file included with the application to test the entire system in a shortened amount of time. Please do the Wet Run before trying an actual batch. Page 21

22 4 Brew-Boss Controller and Brew-Boss App The Brew-Boss system makes brewing as simple as pressing buttons and following textual and voice prompts, assuring successful batches every time. The system consists of two elements, an Android or ipad Tablet running the Brew-Boss application and the Brew-Boss Controller. The Brew-Boss Controller contains a small microprocessor that communicates with the Brew-Boss App and controls the Solid State Relays (SSRs) for the heater and pump. It also controls the optional Hops Boss Automatic Hops Dispenser. The Brew-Boss Controller also has a 12 character numeric LCD display that displays the current kettle temperature, heater power, pump state, and the hops feeder position. The Brew-Boss Controller does nothing on it's own. It receives it's operating instructions from an Brew-Boss App that is connected to the controller wirelessly via a Wi-Fi interface. For this reason, the Brew-Boss App must be running during brewing! We recommend you set your tablet's display Sleep settings to Never to prevent the tablet from entering sleep mode. Also, try and run your tablet off AC power and not battery. Many tablets have power saving features that put the wi-fi radio in a low power mode when on battery, and this could cause disconnection issues. Some tablets have an advanced wi-fi setting that allows you to disable wi-fi power optimization as well. You should disable this optimization if the option is available. The application requires Brew Steps defined by the user (Section 5) and system parameters (Section 6) to be properly configured for proper operation. Sample screen showing user selectable functions on the screen. Page 22

23 Target Temperature This window shows the current target temperature (setpoint) that the controller is trying to heat to and maintain. This value is automatically obtained from the current brew step (see section 4). It is also a drop-down list. Clicking on this window will present a list of temperatures that the user can use to override the controller and manually set the setpoint. This overrides the setpoint as defined in the current step. Simply scroll the list up or down to locate the desired setpoint and then click on the new setpoint. Please note that the next step to execute will use the value determined by the step definition, not the override value. In other words, the setpoint override only lasts to the end of the current step. Time Remaining This Step This window shows the time remaining for the current step being processed, and thus only displays a value when Step Type 4 is being processed or you manually set the timer. Clicking on this window allows you to enter a time value to count down from or to modify the current timer value when a step type 4 activity is active. Simply click on this window and enter a new timer value in minutes. e.g. 1.5 hours is 90 minutes. Hops Feeder Position Th is window shows the current position of the Hops Boss automatic hops feeder if it is installed. Clicking on the window allows you to manually position the hops feeder to Home or any of the 7 hops dispenser tubes. Clicking on the window brings up a simulated image of the hops feeder with the current position shown in RED. Simply click on the desired location to index the feeder to that position to or press the RED position to exit without changing the current position. Brew Mode These two radio buttons allow you to select the brew mode. Brew Mode can either be Auto or Manual and is selected by clicking on the desired mode. When in Auto Mode, the controller will automatically proceed from one step to the next. When in Manual Mode, the controller will complete the current step and then stop, requiring the user to manually start the next step. Manual Brew Mode is used when you want to modify the standard process and manually interact. The default Page 23

24 value for Brew Mode is set in the system parameters screen. The default value is the value that the controller uses when the application starts up. You can go between manual and auto modes during your brew session if desired. The brew mode is only used to tell the controller to automatically proceed to the next step or not, it is not used for Manually Brewing. If you want to use the controller to manually brew (not using brew steps), you can simply use the heater, pump, and timer controls on the main screen manually. Pump Toggle Button This Toggle button shows the status of the pump and allows the user to manually override the status of the pump. On when the pump is running, and Off when it is not. Every press of the button changes the state to the opposite state. Note that when in Auto Brew Mode, when application steps to the next brew step, the state of the pump on the new brew step will override this button in the event it was used as an override. Heater Toggle Button This Toggle button shows the status of the heater. If ON, the application is trying to heat to or maintain the temperature in the Target Temperature window. If OFF, the heater power is forced to 0%. This button allows the user to manually override the status of the Heater. Every press of the button changes the state to the opposite state. Note that when in Auto Brew Mode, when application steps to the next brew step, the state of the Heater on the new brew step will override this button in the event it was used as an override. The Heater Power % graph gives a graphical representation of the heater's power level. The horizontal red bar changes in length corresponding to the power level. The power level in % is also indicated inside the power bar. Heater Power Slider The power slider (yellow band with gray slider button) allows the user to change the power output of the heater manually. This gives the user very accurate control of the power output by simply sliding the slider left or right until the desired power setting is displayed and releasing the slider. This is very useful when your operating parameters might not be set ideally and you want to manually adjust the power output. This is most helpful during the boil to reduce power temporarily during the hot break to prevent over boiling. Note that during a brew session, the power output override will override the power defined in the system parameters, until the temperature drops below setpoint (negative change), at which time the controller will choose it's own power setting to attempt to hold the setpoint. Green Start (Enter) Button This button is the most used button on the controller. If all brew steps and system parameters are configured properly before a brew session starts, the entire brew session can be completed by only pressing this button! Truly a 1 button brew controller! All the other areas on the main screen are used to override the controller in some way, usually the result of a misstep in step definition or parameter setting. Page 24

25 Pressing this button when the system is idle starts the brew process from the 1 st step in the brew step definition table. This button is also used to confirm user interactions requested by Step Type 1. Red Stop/Pause Brewing Button This button is used to Stop (cancel) or pause brewing. The button only appears during an active brew session. Pressing it immediately stops the pump and the heater from operating, so it can be considered an emergency stop button in that sense. When pressed, the application will ask you if you are certain you want to stop brewing. If you are press the Yes button, and the current brew session will be terminated. If you press No, the application will resume the brew session where it left off. Elapsed Time Reset and Power Windows This area becomes visible once brewing is started on Auto Brew Mode from the beginning (first step). It keeps track of the cumulative brew time and also calculates the power used and the corresponding power cost for the brew session. For this to be accurate, you must make certain the system parameters for Heater Watts and Cost per KW Hour are properly set in the system parameters. If you click on the Elapsed Brew Time title, the application will ask you if you want to reset the brew timer. If you respond Yes, the controller will zero the brew timer and start over. Open Menu A yellow menu icon button is provided in the upper right comer of the screen. The standard Android menu button has been disabled in the Brew-Boss app as many newer devices no longer have menu buttons. Clicking on the menu icon may vary on various tablets) opens the application menu. When clicked, the following menu will appear in some fashion based on the make and model of Android tablet. The menu functions that are available are: Define/Edit Brew Steps See Section 4 Save Current Brew Steps This saves the brew step definitions with a name you specify Load Saved Brew Steps Allows you to recall a saved Brew Definition file Page 25

26 Convert BeerXML to Brew Steps (Android Only) Allows you to automatically create Brew-Boss brew steps from a BeerXML export. Many oftware applications such as BeerSmith and Beer Alchemy or from BrewersFriend.com and other beer recipe creation tools can export BeerXML files. You must copy the BeerXML file to the BrewBoss/BeerXML folder on the Android Tablet before running the Brew-Boss app and using this function. Please be aware that the BeerXML converter handles most brewing situations but it does not handle hops additions that occur after flameout, these hops additions will be added to the final hops addition whenever that was. The converter will create brew steps that include manual hops additions, unless you have the Hops-Boss enebled in your parameters, in which case the brew steps will automatically be created for the Hops-Boss. Also, the converter will not handle any cooling steps that you may have in your BeerXML file. Edit Parameters See Section 5 More - Clicking on More brings up these additional menu selections: Fermentation Control The Brew-Boss controller had built in fermentation control capability (controller firmware V1.04 and greater). This menu option will display an input screen (see screenshot below) that allows you to set your fermentation temperature and put the controller into fermentation mode. Simply use the dropdown list to select your desired fermentation temperature and then hit the Save and Close button. The controller will handle fermentation control without the Brew-Boss app running once it is set up using the app. To stop fermentation mode, simply turn the controller off or select Off in the fermentation Control window and then hit the Save and Close button. The LCD on the controller will Indicate the start and end of fermentation modes. While in fermentation mode, the LCD on the controller will alternate between the normal screen that shows the current temperature and a seconds screen that displays the current fermentation setpoint. Fermentation control assumes you have a jacketed fermenter or a chiller coil in your fermenter that chilled water is forced through either by a pump or tap water pressure. You may also use the electric Page 26

27 heater if you have the capability of mounting the Brew-Boss heater into your fermenter. The electric heater is used to warm your beer and the pump circuit to cool your beer. The heater is limited to 10% power output to avoid killing yeast. Your cooling device (water pump, aquarium chiller, solenoid valve, etc.) gets plugged into the pump connector on the controller. When the temperature of the fermenter increases above the setpoint, the pump circuit will turn on directing chilled water to the fermenter. If the temperature drops below setpoint, the heater will be energized at 10% power to raise the temperature to the setpoint. FTP Import BeerXML (Android Only) The menu option allows you to import a BeerXML file using an FTP server. This makes it easier to import files to the tablet. To use this function, you must have previously entered your FTP Server information into the parameters using the Edit Parameters menu. Please note that the FTP settings if changed in the parameters do not take effect until the app is restarted. This option assumes you know how to install and set up an FTP server as instruction on that is beyond the scope of this document. Set Hops Boss Timers This is used to set the timers in the stand-alone version of the Hops-Boss. The stand-alone version operates without the Brew-Boss application. Do not use this feature if you are incorporating you re your Hops-Boss hops additions into the step definitions. Visit Brew Boss Web Site Brings up the Brew Boss web site in the Browser. Your tablet must be connected to the internet before invoking this function. Test Alarm and Tests the Alarm as well as the notification if you are using that feature. Allows you to sample the volume and make sure the alarm works properly. Brew Log via Brew-Boss Sends log of your brew session to Brew Boss tech support using Brew-Boss internal client. Use as requested by support. Your tablet must be connected to the internet before invoking this function. Share Brew Log Sends log of your brew session to Brew Boss tech support using an client on your tablet. Use as requested by support. Your tablet must be connected to the internet and you must have an operational client on the tablet before invoking this function. View Operation Manual Opens this document from the Brew Boss web site. Your tablet must be connected to the internet and a pdf viewer installed before invoking this function. Invert Pump Used on legacy systems do not use this unless instructed by support! Similar menu functions are also provided on the ipad version of the Brew-Boss application. 5 Defining Brew Steps The Brew-Boss system allows the user to define his/her own steps to facilitate varying hardware setups, brew methods, and styles. The brew process is defined by the user using spreadsheet style data entry using the Define/Edit Brew Steps menu entry in the Brew-Boss application. These steps can be saved and recalled as needed. Page 27

28 Note: The temperature can be defined as Fahrenheit or Celsius in the system parameters. It is important that the temperatures entered in the steps below use the same temperature units as is defined in the system parameters. There are five (5) unique brew step types that allow you to define nearly any brew process or session. Yes, only 5 step types allow you to define any brew session! All 5 steps require the same parameters be entered, although some steps do not use all parameters. The parameters corresponding to the columns in the spreadsheet are defined below. Step Parameters Step Type This is a number from 1 to 5 indicating the step type as defined below. Prompt This is the text that will be displayed by the application to identify to the user what step is being executed. It is also the prompt that will be verbally enunciated if the TTS option is enabled for that step. Note: The Prompt parameter cannot include any commas or quotation marks! Setpoint This is the temperature that the controller should heat to and/or maintain for the step being defined. Enter zero if the heater is not required for the step being defined. Temperatures must be in the same units as is defined in the system parameters. Step Timer This is the time for this step and only applies to step type 4 as that is the only step that incorporates a timer. The time should be entered in minutes. So 1.5 hours would be 90 minutes. Boil Flag This parameter tells the controller that we are trying to boil the contents of the kettle and is only used for step types 3 and 4. As the temperature that a wort will boil is dependent on the specific gravity of the wort and the barometric pressure, the temperature that the wort will boil is unknown. Please note that water does not boil at 212F (100C) everywhere! It only boils at 212F (100C) at seal level on a standard pressure (29.92 in Hg) day! If you are at a higher altitude or barometric pressure is low, your wort may boil at as low as 205F. It is important that the controller knows the boil temperature to maintain, otherwise it would stay at full power through the entire process and would not know when boiling commenced. This flag set to 1 tells the controller that it should detect boiling, once detected, store the temperature value where the wort boiled for the following steps and then proceed to the next step. It is best to set the setpoint for any step where you set the Boil Flag to 1 to a value of 220F or 105C, guaranteeing it reaches boil. Set this value to 0 when setpoints for mashing, etc. are set. This flag tells the application that we are not trying to reach a specific setpoint, instead, we want it to determine automatically what the boiling temperature is for the current conditions. The application looks at the slope of the temperature rise curve and determines when that slope levels off, which is the point where the temperature ceases to rise. That indicates that the kettle Page 28

29 is boiling. At that time, the boil temperature is recorded, and the power is reduced to PwrB. Make certain to set the Boil Flag for any step that involves boiling so that the program knows to use the PwrB value. Pump Flag This parameter tells the controller that you want the pump turned on for the step. Setting it to 1 turns the pump on when the step begins. Setting it to 0 forces the pump off. Hops Feeder Position This parameter is used when the Optional Hops Boss automatic hops feeder is installed. This tells the controller which hops positions (0-7) to dispense to the kettle, where position 0 is home. Values entered for the hops feeder must be sequential. i.e. when defining your brew steps, you can't ask to dispense from position 3 before positions #1 and #2 have been dispensed. There is a special case here where the amount of hops you want to dispense does not fit in a single dispenser tube. Each dispenser tube holds about 2oz of pellet hops. If for instance you had 3oz of hops you wanted dispensed at 15 minutes into the brew cycle, you would initially divide the 3oz between two sequential dispenser tubes, say for example dispenser tubes #2 and #3. For this example, lets say you dispensed 1oz of hops from dispenser tube #1 at the commencement of boil (boil hops). Then, after 15 minutes elapsed, you wanted all 3ozs of the 2 nd addition to be dispensed, you would specify dispenser tube #3, as the system will automatically dispense the hops in dispenser tube #2 when it is rotating to position #3. Set this parameter to 0 if the hops feeder is not installed. Speak This parameter tells the controller that you want the Prompt parameter described above to be verbally enunciated by the controller. The controller will read the text you defined in the Prompt field. Setting this parameter to 1 enables text speech output for that step and setting to 0 does not use speech. Do not use quotation marks or commas in your prompts. In general, any punctuation other than the period. is not recommended. Remember when creating your prompts, that the system will be speaking these prompts so word them appropriately so they are understandable. For example, use the entire word first vs the commonly used 1 st abbreviation as seen in the example brew step definition later on in this section. Alarm Flag This parameter tells the controller to sound an alarm to alert the user. Setting to 1 enables the alarm and 0 disables the alarm for the current step. If you have entered an address and are connected to a local network with internet service, the system will also send an when the alarm is triggered. Brew Step Types The five (5) step types are defined as follows: Type 1 Prompt User with User Confirmation Required. This step type is used to pause the program to request the user perform some action. After the user completes the action, he/she presses the Green Start button on the Brew-Boss application screen. When the user presses the Start button, the next step is processed in the sequence shown on the step definition spreadsheet. Page 29

30 Type 2 Prompt User Without Confirmation This step type is used to prompt the user for informational purposes without requiring that they confirm. This step does not pause brewing and basically immediately proceeds to the next step. This step type is most often used with the hops feeder to tell the user that hops have been added automatically. This step does not modify any times or temperatures. A brew step type 3 or 4 is usually mandatory after a step type 2. Type 3 Heat Kettle to Specified Setpoint This step type is used to tell the controller to heat the kettle to a specified temperature (setpoint) and then continue to the next step. Once the setpoint temperature is reached, the controller will turn the pump off if it was on. If Auto Brew Mode is selected, the heater will stay on for the next step, maintaining the specified setpoint. If Brew Mode is set to Manual, the pump and heater will both be turned off at the end of this step. Type 4 Maintain Temperature for Specified Time This step type is used to tell the controller to maintain a temperature (setpoint) once reached by step type 3 for a specified period of time. Type 5 Cool Kettle to Specified Setpoint This step type is used to tell the controller to wait until the kettle temperature cools to a temperature (setpoint). This is the opposite of step type 3. This step involves no heating. It is typically used when an immersion chiller is installed to run the pump until the kettle reaches yeast pitching temperature. It can also be used for hop stands. To define your brew session steps, from the main screen enter the application menu and then select Define/Edit Brew Steps. A spreadsheet style data entry screen like the following will pop up. To add or insert a step (row), long press on the line before or after where you want to add the row and choose to insert the row before or after the selected row. To delete a step (row), long press on the row you want to remove and select delete on the pop-up menu. Note: It is best to only edit these steps when not actively brewing. The system allows you to edit the steps during brewing in the event a change is really necessary, but it is not advisable as the controller stops controlling the brew session and should some timer expire while editing, unpredictable things can happen. Page 30

31 The above image shows the first 12 steps of a typical BIAB brew session. The columns correlate to the Step Parameters defined above. Study the table above to understand how to set up your own brew session. The step by step walk through below of the basic BIAB process with this system will help with understanding. Make sure to read the section later in this document that describes how the Brew- Boss system handles the mashing process before attempting to change the settings below. A thorough understanding of the mash process is essential. Step by Step BIAB Example Step 1 Fill kettle with water: This is defined as a Step Type 1, prompt the user and require confirmation, as indicated by the 1 in the first column under Step Type. The prompt is Fill kettle with water. We are telling the user to fill the kettle with water to the desired water level for the recipe being brewed. For this prompt step, all the parameters are set to 0, except the Speak parameter, which is set to 1 indicating we want the controller to verbally enunciate the prompt to the user as well. In this case, the controller will display the Fill kettle with water prompt in the prompt window on the Brew- Boss application (the application) screen and also verbally announce the same prompt to the user. The application will then wait for the user to press the green Start button on the application screen when he/she finishes adding water to the kettle. If the controller is in Auto Brew Mode, the controller will proceed to the next step. Please note that for step type 1, the program automatically adds when finished, press the green start key to the prompt. Step 2 Place cover on kettle and open the valve: This is also defined as a Step Type 1, as we now Page 31

32 want the user to Place the cover on the kettle and open the valve. This forces the user to perform the steps in the proper sequence. We could have added this prompt to the first step, but opening the valve before adding the water is a bad idea, as it might start dumping water all over the floor. We want this step as we plan on recirculating the water with the pump while we heat the kettle to strike temperature. This is recommended as the recirculation equalizes the temperature in the kettle assuring the temperature is consistent throughout the kettle and that the controller is getting an accurate measurement of the temperature. Again, the user must press the start key to advance to the next step if the controller is in Auto Brew Mode. Step 3 Heating water to strike temperature of 154 degrees: In this step we want to heat the kettle to strike temperature of 154F while recirculating with the pump. So, we have set the Step Type to Step Type 3, Heat Kettle to Specified Setpoint. We define the prompt to Heating Kettle to Strike Temperature of 154 degrees. We set the Setpoint to 154. We set the Pump Flag to 1 indicating we want the pump ON. And we like audible prompts, so we set the Speak flag to 1 as well. This step definition will turn the heater on and pump on and will terminate when the kettle reaches the strike temperature of 154 degrees. We set the Alarm Flag to 1, so the controller will sound the alarm to alert the user that their presence is required! The pump will be turned off at the end of the step but the heater will continue to hold the 154F setpoint, unless Manual Brew Mode had been selected, in which case both the pump and heater will be turned off. Step 4 Water at strike temperature. Please close valve and add grains: This step is initiated after step 3 completes, i.e. the kettle reaches 154F degrees. Since the kettle is at the desired strike temperature, we now want to add the grains to the kettle. To do this, we need to remove the cover. Removing the cover requires that we close the valve or else very hot water will flow out through the pump! For that reason, this step prompts the user, using Step Type 1, to Close the valve and add grains. It also notifies the user what the status is, which is why the Water at strike temperature was included in the prompt. You can make these prompts anything you want, just don't use quotation marks or commas! After the user completes adding the grains and presses the Start button, the controller proceeds to step 5 if the controller is in Auto Brew Mode. Step 5 Place cover on kettle then open the valve: This is also defined as a Step Type 1, as we now want the user to Place the cover on the kettle and open the valve again for mashing. We want this step as we plan on recirculating the water with the pump while we Mash. Again, the user must press the start key to advance to the next step after he/she places the cover and opens the valve. Step 6 Heating to mash temperature of 152 degrees for the first mash step: This step uses Step Type 3, heat to a setpoint. It is possible that we calculated our strike temperature wrong or we took a long time to add the grains and the heater was off because we are in Manual Brew Mode. In these cases, the temperature of the kettle dropped below the desired mash temperature of 152F. This step is included to make sure the kettle is returned to the proper mash temperature before the mash timer is started. Step 7 Maintaining Temperature of 152 degrees for the first mash step: This step uses Step Type 4, which maintains specified temperature for a specified amount of time. In this case, we want to Page 32

33 process our first mash step and maintain 152F for 1 hour (60 minutes) with the pump recirculating worth through the grain bed. We set the prompt to tell the user what we are doing, set the Setpoint to 152F, set the Step Timer to 60 minutes,. We also set the Speak flag to verbally enunciate the commencement of this step. When the timer expires, the controller proceeds to the next step when in Auto Brew Mode. Step 8 Heating to mash out temperature of 168 degrees: We now want to raise the temperature of the kettle to our mash out temperature of 168F. We use Step Type 3 again. We set the appropriate prompt, set the setpoint to 168F, keep the pump recirculating, and of course tell the user verbally what we are doing with the Speak Flag set to 1 as well. If Auto Brew Mode is selected, the controller will automatically advance to the next step when the temperature of 168F is reached. Step 9 Maintaining mash out temperature of 168 degrees: This step again uses Step Type 4, which maintains specified temperature for a specified amount of time. In this case, we want to process our Mash-Out step and maintain 168F for 15 minutes with the pump recirculating worth through the grain bed. We set the prompt to tell the user what we are doing, set the Setpoint to 168F, set the Step Timer to 15 minutes,. We also set the Speak flag to verbally enunciate the commencement of this step. When the timer expires, the controller proceeds to the next step when in Auto Brew Mode. Step 10 Mash out complete. Please close the valve and remove the cover: This step starts after the Mash-Out step completes. We now use Step Type 1, as we now want the user to Close the valve and remove the cover so we can begin boiling our wort. We use the Speak and Alarm Flags to tell the user that his/her attention is required. We make certain the Setpoint stays at 168 so the temperature of the kettle is maintained. Again, the user must press the start key to advance to the next step after he/she removes the cover and closes the valve. Step 11 Please remove the grain bag and install the automatic hops feeder: Now we need to have the user remove the spent grains from the kettle and then install the automatic hops feeder. We again use Step Type 1, as we now want the user to remove the grain bag and install the hops feeder so we can begin boiling our wort. We use the Speak and Alarm Flags to tell the user that his/her attention is required. We set the Setpoint temperature to boiling (220F) to get a head start on heating the kettle to boil. We also set the Boil Flag to 1 to instruct the controller to automatically detect the temperature where boiling commences. We use 220F to assure we reach boiling, so we choose a temperature we know will produce boiling in any environment (220F or 105C). Again, the user must press the start key to advance to the next step. Step 12 Please add your hops to the feeder in appropriate positions: Now we need to have the user add the hops to the appropriate hops feeder dispenser tubes. This step prompts the user to do this while the kettle is heating to boil. We still want the controller to automatically detect boil temperature and want the prompt enunciated as well, so those flags are set to 1. The user must press the start key to advance to the next step after adding the hops. Page 33

34 The following image shows the remaining steps of the BIAB step definition screen example Step 13 Heating wort to boil: We now want to raise the temperature of the kettle to Boil, which we already got a head start on in the previous steps. We use Step Type 3 again. We set the appropriate prompt, set the setpoint to 220F, turn the pump off, and of course tell the user verbally what we are doing with the Speak Flag set to 1 as well. We also set the Boil Flag to 1 to tell the controller we want it to automatically detect and store the boil temperature. If the Boil Flag is not selected, this step will never terminate if the setpoint entered is never reached. (See the Boil Detect Time definition in the System Parameters section of this document for a description on how the controller detects boiling). If Auto Brew Mode is selected, the controller will automatically advance to the next step when the Setpoint is reached or boiling is detected.. Step 14 Boiling state reached. Add boiling hops: When we get here, the kettle has reached boiling, so typically Boiling Hops are added. Because we are using the Hops Boss automatic hops feeder in this example, we use Step Type 2 for the first time. Step type 2 allows us to prompt the user (give a status update) but not require their interaction. If we were not using the Hops Boss automatic hops feeder and instead wanted the user to manually add hops, we would use Step Type 1. So we prompt the user Boiling state reached. Adding boiling hops. We set the Setpoint to 220F with the Boil Flag still set to 1 to tell the controller to use the stored boil temperature that it automatically determined. Since we placed our Boiling Hops in dispenser tube #1, we set the Hops Feeder Position (Hops Pos) to 1. At this time the controller will rotate the feeder to empty hops dispenser tube #1 into the kettle and tells us Page 34

35 it did that via an audible prompt as well. The Alarm Flag is also set as we want to make certain that the user gets to see the awesome Hops Boss automatic hops feeder in action! Since this is step type 2, the controller proceeds to the next step automatically if Auto Brew Mode is active. Note: If we did not want the user to witness the awesomeness of the Hops Boss automatic hops feeder in action, we could have just specified Hops Pos #1 in the next step. Step 15 Maintaining Boil: Now we want to maintain the boil for 60 minutes, but we have a hops addition we'd like with 15 minutes left in the boil. This is where a complete understanding of the controller relative to timing is important. Basically, every time that step type 4 is used, it starts a timer from that point, and the expiration of that timer represents the end of that step. So if we want to have a 60 minute boil, but want to interrupt that with a hops addition, we need two separate timer steps. The first for 45 minutes and the second for 15 minutes, for a total of 60 minutes. So, we use Step Type 4, which maintains specified temperature for a specified amount of time. In this case, we want to maintain boil for 45 minutes. Se we set our Prompt to Maintaining Boil and set the Setpoint to 220 and the Boil Flag to 1 to use the automatically determined boil temperature that was discovered in the heat to boil step. We also keep the Hops Pos parameter set to the last used position. This prevents the hops feeder from reversing, so we set that to 1 in every subsequent step up to the next hops addition. When the timer expires, the controller proceeds to the next step when in Auto Brew Mode. Step 16 Add finishing hops and Irish moss: The wort has been boiling for 45 minutes based on the previous step. Now we want to add the Finishing Hops and some Irish Moss. We have added those items to hops feeder dispenser tubes #2 and #3 respectively. Since we want to witness the awesomeness of the Hops Boss automatic hops feeder in action again, we added this step using Step Type 2, other wise we could have just used Step type 4 immediately (step 17 the next step) with the proper hops feeder position identified. So here we set the Setpoint to 220, Boil Flag to 1, Hops Pos to 3 and the Speak and Alarm flags to 1 as well. We set the Hops Pos to 3 because in order to get from position #1, where it was before this step to position #2, it must pass position #2. So by setting it to 3, positions #2 and #3 both get dispensed. Step 17 Maintaining Boil: Now we want to maintain the boil for the remaining 15 minutes as we have already boiled for 45 minutes. So, we use Step Type 4, which maintains specified temperature for a specified amount of time. In this case, we want to maintain boil for 15 more minutes. Se we set our Prompt to Maintaining Boil and set the Setpoint to 220 and the Boil Flag to 1 to use the automatically determined boil temperature that was discovered in the heat to boil step. We also set the Hops Pos parameter set to the last used position which is 3 as we want to assure it had time to get to that position from the last step. When the timer expires, the controller proceeds to the next step when in Auto Brew Mode. Step 18 Add chiller to kettle: Our final 15 minutes at boil has expired, now it is time to chill the wort. We instruct the user to add the chiller to the kettle. We use the Speak and Alarm Flags and change the Setpoint to 70, which will effectively turn the heater off and serve as a reminder where we want to chill to. Again, the user must press the start key to advance to the next step. Once the chiller is added. Note, frequently I will add 5 minutes to my boil time and add another 5 minutes of boil after this to sanitize the chiller. For this example that was omitted as not everyone uses an immersion type Page 35

36 chiller. Step 19 Place cover and open valve: The recirculation system works great for speeding the chilling process by recirculating the wort over the cooling coils. To accomplish this, we need the cover ion place and the valve open. This step uses Step Type 1 again, requesting confirmation. We also use the Speak and Alarm Flags. Step 20 Recirculation: We use Step type 4 for this as the timer works well to create a stop point as the controller will not trigger on declining temperatures (cooling). So we set the timer value to 15 minutes which can be adjusted according to your chiller. Once the 15 minutes expires, the final step is processed, provided the controller is in Auto Brew Mode. With V1.20 and above of the Brew-Boss App, we recommend using step type 5 for this step. Step 21 Brewing Complete: This step is included to turn everything off and uses Step Type 2. A simple prompt only with just the Speak and Alarm flags set. Important Note: As you can see from the example above, the system is very flexible, but with flexibility comes responsibility. Make certain to thoroughly think your steps out and make certain the heater is not turned on without water in the kettle, or that the valve is open before turning the pump on, etc. Damage can occur to these devices or worse yet personal harm can occur if not careful (e.g. spraying scalding water all over yourself). Use the prompts like in the example to force yourself to do what may seem as trivial steps. Sometimes you will not be able to brew as often as you like and what you take for granted today as trivial may be a forgotten step in the future when you brew again. Page 36

37 6 Setting System Parameters Menu This menu allows you to set the Power On Default Settings for all the operational parameters. Changing these settings during brewing does not necessarily change the parameters for the active brew session! It is important to make sure these settings are correct before starting brewing. Definitions of paramers are as follows: Wi-Fi Enabled Use this to enable Wi-Fi if you have the Wi-Fi interface in your Brew-Boss Controller. All Brew- Boss Controllers are wi-fi at this time, so make certain this box is checked. If you have a USB cabled version, make certain to un-check this box. Please note that USB cabled versions are only available for Android devices with a USB host port. The ios (ipad) version of Brew-Boss does not support USB cabling. IP Address of Brew-Boss Controller Enter the ip address of the Brew-Boss controller. If you are using the Brew-Boss controller in the default configuration where the tablet is connected to the Brew-Boss SSID network, use the default value of for the ip address. If you connect the Brew-Boss controller to your home or business network, then use the static IP that you assigned to the Brew-Boss controller. Page 37

38 TCP/IP Port for Brew-Boss Controller Enter TCP/IP port number for the Brew-Boss controller. If you are using the Brew-Boss controller in the default configuration where the tablet is connected to the Brew-Boss SSID network, use the default value of 8080 for the port. If you connect the Brew-Boss controller to your home or business network, then use the port that you assigned to the Brew-Boss controller. In most cases 8080 should be the port selected. Temp Units This is the Temperature Units to use in the system. This will change the prompts on the main screen to either Fahrenheit (F) or Celsius (C). Select radio button F or C for this value. Make certain your step definitions use the same units as you have defined here. Enable Hops-Boss Automatic Hops Feeder Use this to enable the Hops Boss Automatic Hops Feeder if you purchased that option. Check the box if you want to use the Hops-Boss. IP Address of Hops-Boss Controller Enter the ip address of the Hops-Boss controller. If you are using the Hops-Boss controller in the default configuration where Hops-Boss connects directly to the Brew-Boss controller, use the default value of for the ip address. If you connect the Hops-Boss controller to your home or business network, then use the static IP that you assigned to the Hops-Boss controller. TCP/IP Port for Hops-Boss Controller Enter TCP/IP port number for the Hops-Boss controller. If you are using the Hops-Boss controller in the default configuration where Hops-Boss connects directly to the Brew-Boss controller, use the default value of 8081 for the port. If you connect the Hops-Boss controller to your home or business network, then use the port that you assigned to the Hops-Boss controller. In most cases 8081 should be the port selected. Enable Hot Break Detect on Hops-Boss The Hops-Boss device has an option for an innovative hot break detection device. If your Hops- Boss device has this option, check this box to enable this feature. Hot Break Threshold Value If you enabled Hot Break Detect, you must specify a threshold value between 1 and The default value is 900 and should work in most cases. If Hot Break detection is enabled, a status slider bar will appear on the screen indicating the current reading of the detector as a number. Select a number at least 100 below the average number you see on that status bar. Enable Optional Analog Input on Hops-Boss The Hops-Boss device has an option for an optional analog input. This is a future feature and is not yet supported. Make certain this is not checked. Page 38

39 Analog Input Minimum Value If you enabled Optional Analog Input, you must specify a minimum value. Default is 0 Analog Input Maximum Value If you enabled Optional Analog Input, you must specify a maximum value. Default is 100 Brew Mode This defines the default Brew Mode. Set to Auto or Manual using the radio buttons. For most users, this should be set to Auto. Do not use this setting to change Brew Mode for the current session, instead, use the radio buttons on the main screen as described earlier. Auto mode simply proceeds automatically to the next step in the brew step definitions. Manual mode stops after each step. Most users will never use manual mode. Boil Detect Time The controller automatically detects boil, but uses this parameter to add time in seconds to the time that the controller detects. This must be at least 30 seconds, set higher if in a cold environment. If your controller detects boil too fast (boil has not started but controller thinks it is), increase this number. Heater Watts This is the power output of the heating element in your system. This value is used to determine the power usage for a brew session. The standard 240VAC element supplied in the USA is 5500 watts. Cost per KW Hour This is your local electricity cost per Kwh in Dollars. The current average for the USA is $0.13 so it should be entered as 0.13 without the $. Address for Alerts This is the address that the Brew-Boss App will send alerts to (whenever you set the Alarm Flag to 1 in the step definitions). This is handy as you can have the Brew-Boss App send you an e- mail or text message to your phone when your attention is required (we don t advise or recommend you be far from your brewing setup during brewing for safety reasons). You can only use this feature when you have configured the Brew-Boss controller to connect to your home or business wireless network that has internet capability. Note that you can use this to send text messages by using the address of your service provider (e.g @vtext.com for Verizon). FTP Parameters The FTP parameters allow you to specify an FTP server where you store your BeerXML file exports. This feature allows you to directly convert BeerXML files to Brew-Boss Step files without having to copy the BeerXML files manually to the tablet. These parameters include FTP Address for BeerXML import, FTP PORT for BeerXML import, FTP Username for BeerXML import, FTP Password for BeerXML import, and FTP Path for BeerXML import. Set these parameters to match your FTP server settings. Please note that the FTP settings, if changed in the parameters, do not take effect until the app is restarted. Page 39

40 The remaining parameters deal with power management for temperature control. We have created our own temperature management technique in lieu of standard PID techniques which can be very difficult to understand as they involve derivatives and integration and other calculus :(. Also, PID by design allows overshoot, and we want to minimize the potential of temperature overshoot as too high of temperatures are the culprits in many brewing failures. For this reason, we believe PID is not applicable to brewing. There are several variables that dictate how accurately your system will control temperatures. These variables include ambient temperature, water volume, sensor delay, etc. Because every environment is different, we have given you the ability to set your own parameters in a much easier to understand manner than setting K values for traditional PID control. Google K values PID and see what we mean! The preceding chart helps describe how the parameters used within the Brew-Boss controller are used. Our target temp is 156 on this chart. The Red line is typical temperature control like your oven works. They simply react too slowly to hold within any decent tolerance. As you can see, the red line drastically overshoots the 156 mark and then because the only option is turn the burner off, the temperature undershoots on the cool down as well. The Blue line represents the temperature control used by the Brew-Boss system. Understanding this curve is the key to setting the parameters for your environment. Don't worry, the defaults are pretty close and you are not going to ruin a batch by using the defaults, but if you want to tweak, this will help you out. First off, the temperature control algorithm in Brew-Boss uses 5 different power settings, 100%, PwrS, PwrM, PwrL, PwrB and Off. When heating initially begins, power is set to 100% as is shown on Page 40

41 the graph. Both the curves are collinear up to 150. Once the temperature gets within Delta T1 of Target temperature, the controller switches to PwrS (PwrS = Slow Down but Keep Positive Heating Slope %). In this case, Delta T1 is 6 degrees so we transition to PwrS at (156 6) = 150. As you can see, the slope (increase in temperature over time) gets flatter so we approach the Target Temperature less drastically so we don't overshoot. So you can see by modifying the PwrS value and/or the Delta T1 value you can approach Target Temperature very gradually at the expense of more time. Once the temperature gets within Delta T2 of Target temperature, the controller switches to PwrL (PwrL = Slow Down More but Keep Positive Heating Slope %). In this case, Delta T2 is 3 degrees so we transition to PwrL at (156 3) = 153. Once Target Temperature is reached, the system transitions to PwrM (Power Maintain %). This power setting is greatly dependent on ambient temperature as it is the amount of power required to maintain the temperature of the kettle to overcome losses to the surrounding environment. You will need to adjust this setting to your needs based on your environmental factors so that the temperature is maintained properly. The Brew-Boss App will automatically tweak this value for you and save that value in your parameters. If there is ever temperature overshoot (over setpoint), the value of PwrM is automatically reduced by 2%. If the temperature then ever falls below setpoint, the value is increased by 1%. At the end of a brew session, the parameters screen will reflect the final working value of PwrM. You may want to make note of it and save it with your saved parameters. PwrB is the power required to maintain a proper boil. Once boiling and Boil Flag is set to 1 in the step definition, this power setting will be used. This is because at boiling, PwrM will be insufficient to get the roll we want as PwrM is designed to maintain a temperature. Since we can't get over boil temp, a little additional power is required to maintain boil. A good way to determine this setting is to use the manual slider bar during the boil part of your brew session and keep record what power setting gives you the boil you like. Then, change the PwrB to that setting. Default values for temperature Control Parameters are as follows and are designed for optimized for a 10 gallon batch (approximately 13 gallon liquid volume). PwrS = 75% PwrM = 20% PwrL = 40% PwrB = 63% Delta T1 = 6 degrees F Delta T2 = 3 degrees F Suggested values for a 5 gallon batch (8 gallon liquid volume): PwrS = 50% PwrM = 10% PwrL = 20% PwrB = 63% Delta T1 = 6 degrees F Delta T2 = 3 degrees F Page 41

42 The Brew-Boss App stores the parameters you enter whenever you make a change to any parameter to a file named lastused.prm. This file is loaded each time the Brew-Boss App is started. If you want to save the parameters for later recall, you can save the parameters to a file you name using the Save Parameters button on the lower right side of the screen. If you select a file that already exists from the file dialog, the existing file will be overwritten. This feature is handy for creating parameter files for varying batch sizes, environments, etc. The parameters used for the last brew session are saved automatically and used the next time the application is loaded. It is a good idea each time you edit parameters to close the application and restart it. Do this by hitting the Android Back/Exit button on the bottom android task bar. You will be prompted if you really want to exit, 2 times! Similarly, you can recall saved parameter files by using the Load Parameters button on the lower right side of the screen. Select a file from the list of saved files in the dialog box. Page 42

43 7 About Mashing The Brew-Boss system allows unlimited mash steps (multi-step mashing). The system allows you to define how many mash steps you desire by simply adding each mash step to your brew step definitions as described above. Make sure that you understand this process so you can properly configure the controller for your desired mash process. The first step in mashing is always heating the water in the kettle to a Strike Temperature (Strike Temp). This is the temperature that the water in the kettle is heated to before the grains are added. The Strike Temp is higher than Mash Temperature (Mash Temp) because adding grains that are cooler than the water will cool the water in the kettle. The goal is that the temperature of the liquid in the kettle drops to the first mash step temperature after the grains are added. For this reason, the water must be heated to a slightly higher temperature than the 1 st mash step temperature. There are many online tools that allow you to calculate this value. In general, for the BIAB method, because we are doing a full volume mash, only a degree or two is typically lost by grain addition.. Remember when using online tools and using BIAB method, that you need to make sure that you are using a full volume mash calculator. The Strike Temp is a function of the weight of grain to be added and the volume of water in the kettle. There are as many theories as there are homebrewers as to the ideal mash process. The simplest, which the supplied default BIAB step definition executes, is a two step mash. Two Step Mash (Default): - Water is heated to 154 degrees F. This is the Strike Temperature. - Grain is Added and temperature drops to about 152 degrees F. - Temperature is maintained at 152F for 1 hour. - Temperature is increased to 168F (This is the last mash step and is commonly called Mashing-Out). - Mash Out temperature of 168F is maintained for 15 minutes after the wort reaches 168F. Multi-Step (4 step) Mash Example: The graph below shows a typical Style Specific Mash schedule. The mash schedule represented by the above graph is a 4 step mash as follows: - 15 Minutes at 113F - 15 Minutes at 140F - 30 Minutes at 150F - 10Minutes at 168F (Mash Out) Page 43

44 Pilsner/Dry Lager Mash Temp (F) Time (min) As you can see, the The Brew-Boss system is flexible enough to handle almost any mash schedule you may want to try. The Brew-Boss system provides three different methods of mashing, BIAB, BIAB with Mesh Basket, and COFI. Brew In A Bag (BIAB) Systems False Bottom for BIAB Systems (10 Gallon Size Shown) The BIAB (Brew In A Bag) method utilizes a mesh bag to contain the grains during mashing. The BIAB system is supplied with a stainless steel false bottom that supports the bottom of the bag and Page 44

45 keeps the bag from touching the heater element. Install the false bottom before starting brewing making certain the support legs are parallel with the heating element of positioned to not touch either element for 120 volt systems. False Bottom for BIAB Systems Installed in Kettle (10 Gallon Shown) A sparge/sprayer wand is provided that attaches to the accessory port on the side of the kettle and sprays recirculated wort over the grain bed in the bag. To install the sprayer wand, simply slide over the Camlock nipple on the accessory port and clamp using the Camlock levers on the sprayer wand. Make certain it is positioned so the holes in the wand are pointed down! BIAB Mesh Bag and Sparge/Sprayer Wand Installed Page 45

46 BIAB Basket Mash Systems The Brew-Boss BIAB Basket mash method is similar to the BIAB method described above, except the mesh bag and false bottom are replaced by a stainless steel mesh basket. This mesh basket holds the grain and is easier to use than the mesh bags and lasts a long time! These BIAB baskets do not have covers like the COFI systems described below. BIAB Baskets for 10, 15, and 20 Gallon Kettles COFI Mash Infusion Systems The Brew-Boss COFI filter is an exciting new patent pending technology that optimizes the efficiency of Brew-In-A-Bag (BIAB) type brewing. The filter is manufactured from stainless steel mesh which holds the grain during the mash process, but allows water to flow through. Page 46

47 COFI Infusion Filter Assembly A central infusion tube, that is perforated with a series of flow-matched holes, extends all the way to the bottom of the filter. During the mash cycle, water/wort is continuously pumped from the bottom of the kettle to the top of the filter, into the central infusion tube, where it is forced through the grain bed. Water passing through the grain bed flows out of the filter to the bottom of the kettle. This Center Out Forced Infusion (COFI) technology assures that all the grain is in constant contact with the mash water and that there are no dead spots. No stirring is required as the system is self agitating and efficiency is thereby optimized. The COFI filter is also very easy to clean, simply invert it in a sink and spray it with your sprayer! Because it is made of stainless steel, it will not rust and will last indefinitely. Page 47

48 Spray Pattern of Central Infusion Tube The central infusion tube is also connected to a false bottom. After mashing is completed, the elbow fitting at the top of the COFI filter is exchanged with a lifting ring. When removing the filter, the filter is lifted by the lift ring. This brings the false bottom towards the fixed cover, allowing the weight of the filter to gently squeeze the grain. This squeezing action extracts much of the trapped sweet wort from the grain, but does not release the off tasting tannins. The COFI filter is supplied with two accessories that thread onto the top of the infusion tube, a 90 degree barbed elbow and a lifting ring. The 90 degree elbow is used during mashing, and the lifting ring is used to lift the basket out of the kettle after mashing. The lifting ring should also be used when filling the COFI filter to prevent grain from getting into the central infusion tube. VERY IMPORTANT: Make certain that when attaching the central infusion tube to the false bottom, that you use a wrench to SLIGHTLY tighten the copper infusion tube to the false bottom. Just 1/8 turn with a wrench is all that is needed. It just needs to be tighter than hand tight! This is because the 90 degree barbed elbow and lift ring will be attached to the tube as well by hand. The center infusion tube must be tighter than hand tight to the false bottom to assure that when the elbow is removed after mashing that the center infusion tube does not thread out of the false bottom. Page 48

49 COFI Infusion Filter Installed in Kettle and Attached to Accessory Port During Mashing, the 90 degree barbed elbow is attached to the infusion tube and the other end is connected to the accessory port as shown in the image above. It is important when installing the COFI filter to make certain the filter is rotated such that the support legs are oriented to not hit the heating element. The tabs that the handle attaches to are aligned with two of the feet, so the proper placement is with the handle 45 degrees to the heating element as shown in the image below. Page 49

50 Proper Placement of COFI Filter 45 Degrees to heater Element CAUTION: During mashing, it is important to ensure that the flow of water into the pump equals the flow out of the pump. This is true for both BIAB and COFI mash methods. The wort/water level should always be above the temperature probe level. Use the flow regulation valve on the pump output to reduce flow appropriately. If grains are crushed too finely or viscous ingredients are used such as rice, oats, or corn, it is possible that the screening on the filter can become plugged, causing a stuck mash (water can get into the filter but not out). In this case, it is possible, especially with smaller batches, for the COFI filter to fill with water/wort such that the supply of water in the kettle outside the COFI filter depletes, both starving the pump and heater element. This could cause dry firing of the heater element, causing scorching or worse yet, permanent damage to the element. Page 50

51 After mashing, if you desire to utilize the grain squeeze feature, follow these instructions. 1. Remove the 90 degree barbed elbow accessory and install the lifting ring accessory. 2. Lift the COFI filter out of the kettle about The saturated grain bed tends to get sticky and wants to stick to the sides of the filter. For this reason you'll need to break the bond between the grain bed and the filter. To do this, using hot mitt gloves or hot pads, press down with both hands at the points shown in the image below. It may take some force to break the bond. 4. Once the bond is broken, lift the filter until the feet are just above the surface of the wort. 5. Once again, press down at the points shown until the grain bed meets the cover. 6. Gently press a little more to extract the trapped liquid between the grains. You don't want to push too hard as to actually compress the grains, as this will extract off tasting tannins. 7. Let the basket hang above the kettle to fully drain while the kettle is being heated to boil. Page 51

52 8 - Brew Day...Example Procedure Brew-Boss V2.07 Operation Manual For your first batch, we recommend the 5 gallon Miller Like recipe #1 below. It is the simplest and least expensive recipe that will allow you to test the system out without risking expensive ingredients should something go wrong. It brews wonderfully using the default settings. Use the Display Parameters option under the Edit Parameters menu to validate that all the parameters are set correctly before starting. This should be standard operating procedure. Follow the steps below to brew: 1. Make sure the equipment is clean and sanitized. 2. Make sure the pump and heating element are plugged into the controller. 3. Make sure the temperature sensor is inserted properly and that the valve is closed. 4. Power up the controller and wait for the Wi-Fi network to appear on the Android tablet. 5. Connect to the Brew-Boss Wi-Fi network on the Android tablet. 6. Start the Brew-Boss App on the Android Tablet. 7. Validate the parameters for your recipe using the edit parameters menu. 8. Load the Default BIAB brew steps file. 9. Make sure Brew Mode is set to Auto. 10. Press the Start button on the controller. The controller will prompt you to add water. 11. Add the desired amount of water for the recipe. 12. Press the Start button on the controller indicating you have added water. The controller will begin heating the water to the Strike Temperature. 13. While the water is heating, weigh out your grains and crush them if required. 14. Pour your crushed grains into the Mesh Bag or the COFI Mash Infusion Filter, depending on the mash method you use. 15. When the water reaches the Strike Temperature, the controller will beep and prompt you to add the grains. 16. Slowly place the entire BIAB bag or COFI filter containing the grains to the kettle. You must lower into the water slowly allowing the grains to saturate so that the water does not overflow the kettle. 17. Pull the excess mesh bag over the outside of the kettle and tie the string if your bag has one or attach the recirculation hose to the COFI filter. 18. Press the Start button on the controller to confirm that you have added the grains. 19. The controller will now prompt you to cover the pot and open the valve. 20. Place the cover on the kettle and open the valve that feeds the pump. 21. Press the Start button on the controller to confirm that you have placed the cover and opened the valve. 22. The controller will now automatically step through the mash process by heating to required temperatures and timing each step. 23. During the mash process, make certain that the flow out of the pump is set appropriately with the flow regulation valve as described in the CAUTION above! 24. With the BIAB Bag method, occasionally, stir the grains in the kettle to get even mashing and to prevent a stuck mash. It is helpful to use the Toggle Pump button on the controller to turn the Page 52

53 pump off so you can lift the cover. Make sure to turn the pump back on after stirring. 25. When the final mash step completes (mash out), the controller will beep and instruct you to close the valve and remove the cover. 26. Press the Start button on the controller to confirm that you have closed the valve. 27. The controller will then beep and instruct you to remove the grain. Lift the bag or COFI filter out of the kettle using the rope hoist or electric hoist and let it hang above the kettle to drain. Let the strainer stay suspended above the kettle until the liquid stops draining (a minute or two). You may add water to the level you need for your recipe at this point. For 10 gallon batches, we usually add water to get level to gallons. 1 gallon will boil off in 1 hour typically, leaving about 11 gallons to the fermenter. A good technique is pour hot water over the grains to rinse the remaining sweetness off the grains. You can start the next step immediately though. Once the strainer is suspended above the kettle, press the Start button to continue to the next step. 28. The controller will now start heating the kettle to boil temperature. One needs to keep a close eye on this step! This is the unknown part of the process. At some point close to boil, the wort will reach a point called Hot Break. At this point, the liquid will begin to foam and left unchecked, will boil over and make a mess. The best way to handle this is to use a spray bottle filled with water and continuously spray the foamy froth with water to keep it from boiling over. After about a minute, the proteins will group together and frothing will cease. 29. Once boil temperature is reached, the controller will beep instructing you to add boiling hops. 30. Add boiling hops if desired and press Start. 31. The controller will start a countdown timer for the configured Boil Time. 32. During the boil, the controller will beep at you and prompt you to add hops for each hops timer you have set. These alarms are reminders only, the controller does not stop or request confirmation. 33. When the Boil Time expires, the controller will beep and notify you that the brew process is complete! 34. Cool the contents to room temperature. If you use a copper coil chiller, simply replace the strainer basket (grain bag removed) and place the chiller in the basket. This will keep it off the heater element. 35. Transfer contents to your primary fermenter and add yeast. Best way to do this is to close the valve, remove the hose from the inlet to the pump, place the hose into your primary fermenter, and open the valve. The valve opening is positioned above the bottom of the kettle slightly to allow most of the sediment to remain behind. 36. Thoroughly clean everything including flushing the hoses and pump with hot water and a sanitizer. That's all there is to it! Experiment with your own recipes. If you come up with some good ones, let us know and we'll add them to the web site for others to enjoy! Page 53

54 Note regarding Rye: We have found that brewing with high concentrations of Rye does not work well with electric brewing. For some reason rye burns and scorches to the heating element and is very difficult to clean off. It can also impart a burnt and smokey flavor to the wort. We recommend avoiding recipes containing rye if possible. Page 54

55 Example Recipes Note: Hops in the recipes below are pellets. Recipe 1: "Miller Like" 5 Gallon Recipe This is a basic drinkable beer that resembles a typical American "blonde" beer. It is a lighter beer that everyone enjoys. If Malt is purchased in bulk (50-55lb) bags, you can expect this recipe to cost a little over $10! 8 lbs pale Ale Malt (2 Row) 1 oz Cascade Hops (Boiling) ½ oz Hallertau Hops (Aroma) added 15 minutes before end of boil 1 tsp Irish Moss added 15 minutes before end of boil 1 packet Safale US-05 Yeast or equivalent Strike Temp 154F Mash Time F Sparge Time 15Minutes at 168F Boil Time 60 Minutes Recipe 2: "Not Flat Tire" 5 Gallon Recipe This is a nice Hoppy Amber. Resembles a popular micro-brewed Amber Ale. 5 lbs Pale Ale Malt (2 Row) 1 lbs Vienna Malt 1.5 lbs Amber Malt 0.5 lbs Crystal Malt 40L 1 oz Cascade Hops (Boiling) 1oz Hallertau Hops (Aroma) added 15 minutes before end of boil 1oz Cascade Hops (Aroma) added 15 minutes before end of boil 1 tsp Irish Moss added 15 minutes before end of boil 1 packet Safale US-05 Yeast Strike Temp 154F Mash Time F Sparge Time 10 Minutes at 168F Boil Time 60 Minutes Page 55

56 Recipe 3: "Mick A. Lobes Amber Bock" 5 Gallon Recipe This is a nice Amber Bock and our favorite recipe. Mick Andrew Lobes drank this and said it was his favorite as well. Here's to you Mick! Cheers! 11 lbs Pale Ale Malt (2 Row) 1 lbs Vienna Malt 2 lbs Amber Malt 1 lbs Crystal Malt 40L 1 lbs Chocolate Malt 2 oz Cascade Hops (Boiling) 1 oz Hallertau Hops (Aroma) added 15 minutes before end of boil 1 oz Cascade Hops (Aroma) added 15 minutes before end of boil 2 tsp Irish Moss added 15 minutes before end of boil 1 packet Safale US-05 Yeast Strike Temp 154F Mash Time F Sparge Time 10 Minutes at 168F Boil Time 60 Minutes Calculating Starting Water Volume We've found that 9 pounds of grain absorbs about 1 gallon of water during mashing. We also lose about 1 gallon of volume per hour of boil. So, for the Miller Like recipe example above, we have 8 lbs of grain, so we'll lose about 1 gallon of water to grain absorption. We have a 1 hour boil, so we'll lose another gallon, totaling 2 gallons lost. If we want 5.5 gallons into our fermenter (allowing for trub loss), we'll need 7.5 gallons of water to start. This same calculation can be made for any recipe. Page 56

57 Configuring Brew-Boss wi-fi Radio for Connection to Home or Business Network In some cases, using the Brew-Boss system in its default state where the Brew-Boss controller acts as its own wireless network (SSID Brew-Boss) is not viable. These cases include those that want to use the alarm feature or have multiple Brew-Boss controllers operating in the same area. If you can use the Brew-Boss Controller in its default state, you do not need to reconfigure the wifi radio. Only perform the steps below if you need to operate on your own wireless wifi network! These instructions will walk you through reconfiguring your controller to operate on your home or business wireless network. Please follow the instructions carefully, and attempt only at your own risk. Re-configuring the radio improperly can render your Brew-Boss system inoperable, requiring you to send it back to us and is not covered under warranty. IMPORTANT: IF YOU ARE USING THE HOPS-BOSS AUTOMATED HOPS FEEDER, YOU MUST RECONFIGURE IT FIRST, BEFORE RECONFIGURING THE Brew-Boss CONTROLLER! The Brew-Boss and Hops-Boss controllers are equipped with a wi-fi radio device as well as thier own microprocessors. The wi-fi radio must be re-configured to communicate with your internet enabled home or business wireless network if you want to use the notification feature of the Brew- Boss app or are using multiple Brew-Boss controllers in the same area (such as a nano brewery or brew on premise operation). You will need to know your wifi SSID, pass codes or access keys if the network is encrypted, and the type of encryption is used. The Brew-Boss controller requires a static IP address and cannot be used with DHCP. If you don t understand what DHCP or static IP addresses are, please consult your network administrator or someone else who does. It is important that you find a static IP address that is available on your network that does not conflict with another device and is outside the DHCP range. If you have the Hops-Boss, you will need two static IP addresses. You will also need to make certain the ports 8080 and 8081 are not blocked by your router s firewall. NOTE: If you do not have a Hops-Boss, skip to Re-Configuring the Brew-Boss Controller to Use Home or Business Network below. Re-Configuring the Hops-Boss Controller to Use Home or Business Network The Brew-Boss Controller in its default state as shipped has a wireless wifi SSID of Brew-Boss and is an open network (has no security encryption). The Hops-Boss Controller is programmed by default to connect to the Brew-Boss SSID of the Brew-Boss Controller. Please follow the instructions carefully, and attempt only at your own risk. Re-configuring the radio improperly can render your Brew-Boss system inoperable, requiring you to send it back to us and is not covered under warranty. Page 57

58 To re-configure the Hops-Boss controller to connect to your home or business network, follow these steps: 1. Power up the Brew-Boss Controller and let it boot up for at least 45 seconds so that the Brew-Boss network is visible from your tablet. 2. Connect the tablet to the wireless network Brew-Boss in wifi settings. 3. Launch the Brew-Boss application. 4. Make certain the application reports that the Brew-Boss controller is connected as shown in the picture below. 5. Power up the Hops-Boss device. 6. Wait for the Brew-Boss application to show that the Hops-Boss is connected as shown in the picture above. 7. Close the Brew-Boss application. 8. Launch the browser on the tablet. 9. In the address bar, type: and hit <enter> or <go> on the keyboard. 10. If you are presented with a logon page, use admin for both the Name and Password fields then touch Sign in. Page 58

59 11. You will be presented with a page like the following image. 12. Click on the SCAN button to the right of the SSID cell with Brew-Boss in it as shown above. 13. You will be presented with a list of wireless networks within range of the Hops-Boss controller. You should see the Brew-Boss network as well as your home or business network SSID. Select the small circle to the left of your network SSID to select it. It should turn GREEN like the one next to Bertram1 below. Page 59

60 14. Next, click on the Apply button on the lower right of the screen to save this network selection. 15. Select the Encrypt Type that matches your network encryption using the dropdown list. Select Open if your network is not encrypted. 16. Enter the network encryption Password of your network if it is not set to Open. This must be EXACT! 17. If IP Type is not set to STATIC, use the dropdown list to select STATIC. DO NOT set to DHCP! 18. Make certain you have identified an IP address that you can use on your network that does not conflict with other devices and is outside the DHCP range your router assigns to other devices. Enter this IP address in the IP Address box. The image below shows as an example. Your address must match your IP range of your router. Write this address down as you will need to enter it in the IP address area of the parameters in the Brew-Boss application. 19. The Subnet Mask should be , if it is not, change it. 20. The Default Gateway needs to be set to the IP address of your router. In the example shown, it is The Primary and Secondary DNS Servers should both be blank as shown in the example Page 60

61 image. 22. None of the other fields should be changed. Confirm they match the example image below. 23. Once you have confirmed all data is correct, click on the Apply button at the bottom of the screen as shown in the image above. Be very certain all the information is correct before clicking on Apply, especially the network encryption password. If it is not correct, your Hops-Boss controller will no longer function! 24. Wait about 1 minute for the Hops-Boss to reboot and attempt to connect to your network. 25. Test that the Hops-Boss was properly configured. Connect your tablet to your home or business network in the wifi settings area. 26. Launch the Brew-Boss application. 27. Load the Edit Parameters screen using the menu. 28. Change the IP Address for Hops-Boss Controller cell to the static IP address you set for the controller above. 29. Make certain the TCP/IP Port for Hops-Boss Controller is set to Click on the Close button on the lower right corner of the Operational Parameters screen to save. Page 61

62 31. Close the Brew-Boss application and restart it. After a few seconds, the Hops-Boss Controller Connection Status should turn GREEN and display Connected (the Brew-Boss Controller Connection Status will be RED at this time as we have not re-configured it yet!). Test it by clicking on the Hops-Boss position and manually moving the Hops-Boss to a different position. Note: If the Hops-Boss does not connect, try removing power from the Hops-Boss and restarting it. If that does not work, it is most probable that you set something incorrectly or your network router is blocking the port. It may be necessary to send the controller back to Brew-Boss for reset. Contact support if this is needed: support@brew-boss.com. Page 62

63 Re-Configuring the Brew-Boss Controller to Use Home or Business Network The Brew-Boss Controller in its default state as shipped is configured as a wireless router and has a wireless wifi SSID of Brew-Boss and is an open network (has no security encryption). Please follow the instructions carefully, and attempt only at your own risk. Re-configuring the radio improperly can render your Brew-Boss system inoperable, requiring you to send it back to us and is not covered under warranty. To change the Brew-Boss controller to become a wifi client instead of a wifi server, perform the following steps: 1. Power up the Brew-Boss Controller and let it boot up for at least 45 seconds so that the Brew-Boss network is visible from your tablet. 2. Connect the tablet to the wireless network Brew-Boss in wifi settings. 3. Launch the Brew-Boss application. 4. Make certain the application reports that the Brew-Boss controller is connected as shown in the picture below. 5. Launch the internet Browser on your tablet. 6. In the address bar, type the following: and hit <enter> or <go> on the keyboard. 7. If you are presented with a logon page, use admin for both the Name and Password fields Page 63

64 then touch Sign in. Brew-Boss V2.07 Operation Manual 8. You will be presented with a page like the following image. 9. Change the NetMode to WFI(CLIENT)-SERIAL by using the dropdown list that appears when you touch the cell that should originally contain WIFI(AP)-SERIAL. The screen should update to look like the following: Page 64

65 10. Click on the SCAN button to the right of the SSID cell with Brew-Boss in it as shown above. 11. You will be presented with a list of wireless networks within range of the Hops-Boss controller. You should see the Brew-Boss network as well as your home or business network SSID. Select the small circle to the left of your network SSID to select it. It should turn GREEN like the one next to Bertram1 below. 12. Next, click on the Apply button on the lower right of the screen to save this network selection. 13. Select the Encrypt Type that matches your network encryption using the dropdown list. Select Open if your network is not encrypted. 14. Enter the network encryption Password of your network if it is not set to Open. This must be EXACT! 15. If IP Type is not set to STATIC, use the dropdown list to select STATIC. DO NOT set to DHCP! 16. Make certain you have identified an IP address that you can use on your network that does not conflict with other devices (including the Hops-Boss if you have one) and is outside the DHCP range your router assigns to other devices. Enter this IP address in the IP Address box. The image below shows as an example. Your address must match your IP range of your router. Write this address down as you will need to enter it in the IP address area of the parameters in the Brew-Boss application. Page 65

66 17. The Subnet Mask should be , if it is not, change it. 18. The Default Gateway needs to be set to the IP address of your router. In the example shown, it is The Primary and Secondary DNS Servers should both be blank as shown in the example image. 20. None of the other fields should be changed. Confirm they match the example image below. Page 66

67 21. Once you have confirmed all data is correct, click on the Apply button at the bottom of the screen as shown in the image above. Be very certain all the information is correct before clicking on Apply, especially the network encryption password. If it is not correct, your Brew-Boss controller will no longer function! 22. Wait about 1 minute for the Brew-Boss to reboot and attempt to connect to your network. 23. Test that the Brew-Boss controller was properly configured. Connect your tablet to your home or business network in the wifi settings area. 24. Launch the Brew-Boss application. 25. Load the Edit Parameters screen using the menu. 26. Change the IP Address for Brew-Boss Controller cell to the static IP address you set for the controller above. 27. Make certain the TCP/IP Port for Brew-Boss Controller is set to Click on the Close button on the lower right corner of the Operational Parameters screen to save. 29. Close the Brew-Boss application and restart it. After a few seconds, the Brew-Boss Controller Connection Status should turn GREEN and display Connected (the Hops-Boss Controller Connection Status should be green as well from the steps above. Page 67

68 Note: If the Brew-Boss controller does not connect, try turning the power off on the Brew- Boss controller and restarting it. If that does not work, it is most probable that you set something incorrectly or your network router is blocking the port. It may be necessary to send the controller back to Brew-Boss for reset. Contact support if this is needed: Page 68

69 Swirl-Boss Whirlpool Wand Instructions The Swirl-Boss wand is designed to connect directly to the accessory port on the 15 and 20 gallon Brew-Boss kettles. It connects using a camlock style connector and creates a whirlpool using pressure from the pump through a custom E nozzle. The special E nozzle will direct flow along the perimeter of the kettle as well as slightly inward to optimize rotation. The Swirl-Boss can be rotated to direct flow parallel to the bottom, pointed toward the bottom, or slightly upwards to direct flow towards the surface. Experiment with varying angles to optimize the rotation speed of the whirlpool. Run the pump at full output (restriction valve open all the way). The best time to whirlpool is after you have chilled the wort in your kettle so that the cold break has already occurred. We've found about 10 minutes is optimum for effective sediment concentration to the center of the kettle. We highly recommend the use of the Brew-Boss pickup tube with this device as that will eliminate the need to tip your kettle to get the las bit of wort out of the kettle when transferring to your fermenter. Page 69

70 Hops-Boss Installation and Use Instructions The Hops-Boss automated hops feeder will make your brew day a joy. Watching the Hops-Boss automatically feed your pellet hops and other brew finings into your brew kettle at the proper times is amazing. Never miss a hops addition again! The Hops-Boss is available in two versions, as an accessory device (slave) to the Brew-Boss electric brew controller or as a stand-alone device that requires programming via an Android or ios application. This document will guide you through setup and use of your new Hops-Boss. Overview The Hops-Boss consists of a stainless steel structure that supports a rotating carrier gear. A stepper motor is used to accurately position the carrier gear. The carrier gear is laser machined with seven holes that loosely retain plastic hops cups (we call them mortar shells because that is what they look like). Each mortar shell can hold up to 1.75 ounces of pellet hops, for a total hops addition potential of over ¾ pound! It is important to note that hops must be placed in the cups in the proper sequential order in relation to the order each hops need to be added. Each hops position is laser etched with the position number on the carrier gear. Thus, you can't randomly select hops locations. Position 1 must dump before Position 2, Position 2 before 3, etc. In the event you want to add more than 1.75 oz at one time, simply divide the hops required into multiple sequential mortar tubes and use the highest numbered feeder position to activate that addition. So for example, if you wanted 3 oz of hops dispensed at once, simply divide the hops into two sequential mortar shells. e.g. Positons 2 and 3. Simply specify the highest numbered location, in this case position 3 for your hops addition and position 2 will be dispensed as well on its way to position 3. Page 70

71 Assembly The Hops-Boss is assembled easily with 8 nuts. Items are assembled as shown in the picture below. If you have the optional heat shield, Make certain to mount the Chute to the Baseplate first, as the heat shield (not shown) will obstruct the fasteners on the bottom of the Baseplate, making them difficult to install. Don't over-tighten the nuts! Just a small amount of torque once the nut makes contact is sufficient. The Carrier Gear and the Hops Cups (Mortar Shells) are shipped installed. To remove the top gear, simply unscrew the center socket head bolt and remove the gear and mortar shells. The shells are loosely retained by the carrier gear, so be careful not to drop any of the mortar shells. They are purposely designed to fit loosely so they ride flush with the baseplate when moving. We have found it easiest to hold the Hops-Boss assembly as shown when removing or installing the top gear as the mortar shells will stay in place in this position. Page 71

72 Clean the Hops-Boss before your first use. To clean, remove the top carrier gear and hand wash the mortar shells in hot soapy water. Hand or air dry. The Hops-Boss contains delicate electronics and is not submersible! Clean the stainless steel surfaces with any household cleaner and paper towel by wiping with cleaner sprayed on towel. (Clorox or Windex wipes work great). Dry with paper towel. After assembling the Hops-Boss unit, power it up by plugging in the power supply (included) to a 120VAC outlet. Plug the other end into the Hops-Boss unit. There is no power switch on the Hops- Boss. Plugging it in powers it up. The RED light on the bottom should illuminate and if the top carrier gear is not already in the Home position, it will automatically turn to that position. Any time the unit is first powered up, it will seek the home position. Configuring Hops-Boss wi-fi Radio for Connection to Brew-Boss The Hops-Boss is equipped with a wi-fi radio device as well as it's own microprocessor. The Hops- Boss Master device (stand-alone) version is designed to be connected to directly and as such it is configured with the SSID of Hops-Boss. Do not change the SSID of the Stand-Alone (Master) version of the Hops-Boss! The slave version of the Hops-Boss is designed to communicate with the Brew- Boss controller directly. The Hops-Boss slave model comes pre-configured to communicate directly to the Brew-Boss controller. If you want to use your home or office network, the e wi-fi radio must be configured to connect to your network. If you purchased the Standalone version of the Hops-Boss, you don't need to do anything with the wi-fi radio setup, as it is shipped properly configured. Also, if you have an older Brew-Boss controller, and your SSID is not Brew-Boss (has an SSID of BrewBoss XXXXXX where the X's represent a unique number), you will need to reconfigure your Brew-Boss controller to have an SSID of Brew-Boss. To change the SSID, perform the following steps: 1. Turn on your Brew-Boss controller and wait for at least a minute for the wi-fi radio inside to boot up. 2. Connect to the Brew-Boss XXXXXX wireless network on your Android tablet as you normally do before launching the Brew-Boss App. Do not launch the Brew-Boss App at this time. Wait for the tablet to show connected for the wireless network. 3. Launch the internet Browser on your tablet. 4. In the address bar, type the following: then hit the enter or go button. If you are prompted for a username and password, enter admin for both. 5. If the foregoing steps were performed properly, you will see a web page display that looks like the following: Page 72

73 6. Change the SSID from Brew-Boss XXXXXX (Brew-Boss in example above) to Brew-Boss typed exactly like shown noting the capitalization! 7. Click the Apply button on the bottom of the screen. Do not change any other settings even if they don't match the ones shown above! 8. Close your browser. 9. Return to your wi-fi settings on your tablet. A new network called Brew-Boss should appear. Connect to the Brew-Boss network. Wait for connected to appear by that network. 10. Optional. Click on your old network name Brew-Boss XXXXXX and click Forget so it gets removed from your saved network list. 11. Launch your Brew-Boss app (make certain you have Version 1.10 or later! If you don't, connect to the internet and make sure to update to the latest version in the Google Play Store or Amazon's App Store). Confirm that it connects to the Brew-Boss controller normally. 12. Change the Use Hops Boss Feeder to true. In the edit parameters menu function. Make certain to press the Close button on the edit parameters screen, as this saves the data. You may also want to name the configuration and save it. 13. Exit the Brew-Boss app by pressing the back button. Confirm exit as usual. 14. Power up the Hops-Boss by plugging in the power plug. The RED light on the bottom should illuminate, indicating it has power. Wait 30 seconds for the Hops-Boss to try and connect to the Brew-Boss controller. Page 73

74 15. Launch the Brew-Boss app again. The Use Hops Boss check box should now appear checked and the Hops-Boss position should now be shown as illustrated in the screenshot below. Note that the backgrounds around the Temperature Header and the Use Hops Boss Checkbox are green in the screenshot above. GREEN indicates that the devices have connected, RED indicates they are disconnected. The Green Temperature box indicates the Brew-Boss controller is connected and the Green Hops-Boss Checkbox indicates that the Hops-Boss is connected. It is important that the controllers be powered up in the order above. First the Brew-Boss controller, wait at least 1 minute, then the Hops-Boss, wait at least 30 seconds, then connect the Tablet to the Brew-Boss network, and finally, run the Brew-Boss app. The screen should look like the one above. Page 74

75 16. Test the Hops-Boss by clicking on the Box with Home shown on the screenshot above. A graphic representation of the Hops-Boss unit will be displayed as shown in the screenshot below. Notice that the current position of the Hops-Boss feeder is highlighted in RED. To test the feeder, simply press on one of the hops feeder position numbers on the graphic. The feeder should befin spinning to the selected position. The display will then show the current position as the feeder reaches those locations as shown below, where we selected position #2. Page 75

76 17. Now you can add automated hops feeding to your step definitions by simply placing the desired position number in the Hops Pos column of the Edit/Define Brew Steps screen. Valid poitions are from 0 (Home) to 7. Remember to make certain that the hops feeder positions are in sequential order as previously described. Important, once a brew step includes a Hops Position greater than 0, you must make certain each subsequent step has a hops position specified as well that is at least the number before it! If you leave a step at 0 (zero), it will force the feeder to return to home or other position specified, turning the feeder backwards. This is not desirable, unless you purposely want to return the feeder to a prior position. Simply repeat the hops feeder position in each step definition until you want it changed to a higher numbered hops location. Below is an example of a Step Definition using the Hops-Boss. In this example, we have a 2oz hop load we want to add when boiling is reached and another 2oz load we want to add with 15 minutes remaining in a 60 minute boil. Because both hops loads are more than will fit in one Mortar Shell, we divided them out evenly between multiple positions. The 2 oz. That we want to add at the beginning of boil are placed in hops positions 1 and 2. The remaining 2 oz. are divided evenly between hops positions 3 and 4. Page 76

77 Line A above shows the step definition for the first hops addition after the kettle reached boil. We use a step type 2 (prompt without user confirm) to move the feeder to position 2. This dispenses the contents of feeder positions 1 and 2. Line B, step type 4, maintains the boil for 45 minutes. Notice here is where we must place a 2 in the Hops Pos column so that the feeder stays at position 2. Line C begins after the 45 minutes of boiling completes. Here we move the feeder to position 4, which will feed both positions 3 and 4. Line D maintains boil for the remaining 15 minutes, to complete our 60 minute boil. Notice that in Line D we used a Hops Pos of 4, to keep it at that position for the remainder of the boil. Because Line C was a step type 2, there would not be enough time for the feeder to move to position 4 as step type 2 is instantaneous. So, we place the 4 for the Hops Pos in Line D as well. Stand-Alone Hops-Boss Operation - FUTURE - Page 77

Automated Electric Brewing System

Automated Electric Brewing System Automated Electric Brewing System Operation Manual V3.03 (For Brew-Boss App Versions 2.07 and later and Brew-Boss Controller V2.0 or Greater) www.brew-boss.com V2.0 Brew-Boss Deluxe COFI System with Brew-Boss

More information

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa

More information

KEG RIVER MICROBREWERY INSTRUCTION MANUAL

KEG RIVER MICROBREWERY INSTRUCTION MANUAL KEG RIVER MICROBREWERY INSTRUCTION MANUAL MODEL NO.: BM-S400M-1 ~ BM-S500M-1 Thank you for purchasing the Keg River Microbrewery system. Please follow the instructions below to get the best from your machine.

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

PROFESSIONAL BREW DEVIL MICRO BREWERY INSTRUCTION MANUAL. Thank you for purchasing this Brew Devil Microbrewery system.

PROFESSIONAL BREW DEVIL MICRO BREWERY INSTRUCTION MANUAL. Thank you for purchasing this Brew Devil Microbrewery system. MODELS: BREWDEVIL30 BREWDEVIL50 PROFESSIONAL BREW DEVIL MICRO BREWERY INSTRUCTION MANUAL Thank you for purchasing this Brew Devil Microbrewery system. Please follow the instructions below to get the best

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert) Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel

More information

Conical Fermenter. Instructions

Conical Fermenter. Instructions Conical Fermenter Instructions What s in the Box?: 01. AIRLOCK Rubber Bung Fermenter lid Fermenter Body CONTENTS WHAT S IN THE BOX...P1 ANATOMY/SCHEMATICS...P2 FERMENTING WITH THE STANDARD FERMENTER...P.5

More information

Instruction Sheet WELCOME TO THE CLUB

Instruction Sheet WELCOME TO THE CLUB Instruction Sheet WELCOME TO THE CLUB Page 1 of 20 www.kegland.com.au Last Updated 17 December, 2018 BrewZilla 65L ALL IN ONE DOUBLE BATCH BREWERY WITH PUMP GEN 3 WARNING IMPORTANT INFORMATION! 1. Please

More information

IntelliSync Thermostat / Mobile App Frequently Asked Questions

IntelliSync Thermostat / Mobile App Frequently Asked Questions IntelliSync Thermostat / Mobile App Frequently Asked Questions This FAQ page addresses the most common questions on Deriva IntelliSync. Why bother setting a heating and cooling schedule? What is ENERGY

More information

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options Spotlight Cam Mount Smart Security at Every Corner of Your Home Your new Spotlight Cam lets you extend the Ring of Security around your entire property. Now, you ll always be the first to know when someone

More information

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION ClearChoice Economy Under Sink Drinking Water System OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION Congratulations on the purchase of your ClearChoice

More information

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS) FOR PROPER AND SAFE USE OF THIS CHEMCHAMP EQUIPMENT, PLEASE FOLLOW THIS DOCUMENT AND LOCAL AUTHORITY. KEEP THIS DOCUMENT FOR FUTURE REFERENCE.

More information

BUNN TECHNICAL TRAINING ICB

BUNN TECHNICAL TRAINING ICB BUNN TECHNICAL TRAINING ICB Index Unit 1: Installation Site Requirements...4 Location of the Serial Number...5 Water Supply Install...5 Electrical Install...5 Initial Start-Up...6 Unit 2: Setup Setup and

More information

Monitor Alarms and Events

Monitor Alarms and Events This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

Water Hero P-100. P-100 Components:

Water Hero P-100. P-100 Components: Water Hero P-100 Thank you for purchasing the Water Hero P-100. The P-100 offers wholebuilding leak detection, mitigation, and water usage monitoring. P-100 Components: Main Controller Water Meter, Sensor

More information

AQUAPEUTICS MONACO INSTALLATION MANUAL

AQUAPEUTICS MONACO INSTALLATION MANUAL AQUAPEUTICS MONACO INSTALLATION MANUAL Monaco schmatic diagram Cross sectional illustration of gaskets Recommended tools 4 5 5 5 5 Installation steps Steam generator hook-ups Troubleshooting n Steam dispenser

More information

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

DryLINK TRAINING Phoenix DryMAX XL and DryLINK DryLINK TRAINING Phoenix DryMAX XL and DryLINK FREE MOBILE APP 125 PPD XL LGR DEHUMIDIFIER WITH BLUETOOTH BE EVERYWHERE AT ONCE TABLE OF CONTENTS Introduction...3 Initial Setup Downloading the App...4

More information

FreezeAlarm Dialer Pro

FreezeAlarm Dialer Pro FreezeAlarm Dialer Pro User Manual for FA-800E Thank you for purchasing our FreezeAlarm Dialer Pro. This instruction manual covers installation for model FA-800E. General Description The FA-800E automatically

More information

Grainfather Connect Control Box. Instructions

Grainfather Connect Control Box. Instructions Grainfather Connect Control Box Instructions TECHNICAL SPECIFICATIONS Waterproof graphic display 30% glass infused ABS plastic for extra strength Vents Power: 2000W Heating Triac - for variable heat control

More information

Washer. 120~volt 60-Hz. IhilPORTANT: Read and save these instructions. Parts supplied:

Washer. 120~volt 60-Hz. IhilPORTANT: Read and save these instructions. Parts supplied: Bi Installation Instructions 120~volt 60-Hz Washer Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read

More information

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS Included Parts: A. 581.1 Solid Bowl B. 58.1LA Vacuum Breaker C. 58.6 Stainless Steel Supply Tube D. 58.29 90º Compression Fitting E. 58.24 Straight Compression Fitting F. 58.7 Vinyl Discharge Tube G. 66.123

More information

IQ PANEL USER GUIDE SMARTHOME.

IQ PANEL USER GUIDE SMARTHOME. IQ PANEL USER GUIDE SECURITY & SMARTHOME www.schmidtsecurity.com USING YOUR SYSTEM: BASICS Navigation Move from page to page and access information on each page using finger touches, swipes, and scrolling.

More information

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: Available in: Sapphire Black and Glacier White. 1 Series Model: Available in: Sapphire Black and Glacier White 1 Series Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure Mode Select Pairing the neohub

More information

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-03 and 89800-04 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

Ontech GSM 9040/50. Reference Manual English -1 -

Ontech GSM 9040/50. Reference Manual English -1 - Ontech GSM 9040/50 Reference Manual English -1 - Content Welcome... 5 This manual... 5 Text styles... 5 Support... 5 Disclaimer... 5 Overview... 6 Accessories... 6 External temperature sensor 9901... 7

More information

L A signature series TA T N E RE O, A L L A T S IN

L A signature series TA T N E RE O, A L L A T S IN signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Robobrew 35L All In One Brewery with Pump Model: 8695

Robobrew 35L All In One Brewery with Pump Model: 8695 Instruction Sheet Robobrew 35L All In One Brewery with Pump Model: 8695 WARNING IMPORTANT INFORMATION! 1. Please read this ENTIRE instruction sheet before using the Robobrew unit. If you are unsure about

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL QUATRO 10/09 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION

More information

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat. Peak Partners Web-Programmable Thermostat Homeowner s Manual Look inside for a complete guide to the setup and operation of your new thermostat. Table of Contents Step 1: Getting Started...4-6 A. Thermostat

More information

U ser's Guide PC6010

U ser's Guide PC6010 User's Guide PC6010 Quick Reference Guide This manual is for Basic and Advanced users. Each of these types of user can access a different set of functions. The and symbols next to the title of each procedure

More information

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series Model: Available in : Sapphire Black and Glacier White 1 Series Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation.

PUMPS COMPATIBLE WITH ANY TYPE OF WATER PUMPING SYSTEM. Instructions must remain with installation. 450455 PUMPS Instructions must remain with installation. 2016 BURCAM Printed in Canada 450456T.2 ALERTS YOU before any water damage occurs from your sump or sewage tank IMPORTANT : Your Wi-Fi Water Watcher

More information

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat. IT801 Thermostat User s Manual The complete guide to the set up and operation of your new smart Wi-Fi thermostat. The smart Wi-Fi thermostat system learns your comfort preferences, then finds opportunities

More information

EVac II Programmable Digital Vacuum Gauge

EVac II Programmable Digital Vacuum Gauge EVac II Programmable Digital Vacuum Gauge Thank you for your purchase of the YELLOW JACKET evac II Digital Vacuum Gauge. The evac II is the most accurate and precise vacuum gauge available today with patented

More information

347002K/177002K/34900

347002K/177002K/34900 Service Manual Models: 347002K/177002K 34900/347012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation and Safety Precautions... 2 Depressurizing

More information

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-

More information

The Ruby Street Brewery. Owners Manual. Ruby Street Brewing, LLC. Fort Collins, Colorado USA

The Ruby Street Brewery. Owners Manual. Ruby Street Brewing, LLC. Fort Collins, Colorado USA The Ruby Street Brewery Owners Manual Ruby Street Brewing, LLC Fort Collins, Colorado USA Table of Contents Introduction 3 Safety Instructions 4 Brewery Overview 5 Kettle Assembly 6 Proper Kettle Placement

More information

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Personal Reference Guide Brighten ithermostat Thermostat Guide Online Guide Brighten Conservation Program Welcome to your new Brighten ithermostat

More information

WeatherLink for Alarm Output Addendum

WeatherLink for Alarm Output Addendum WeatherLink for Alarm Output Addendum Introduction This Streaming Data Logger is designed to provide an electrical interface between a Vantage Pro or Vantage Pro2 weather station console or Weather Envoy

More information

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White Model: Available in: Sapphire Black and Glacier White 1 Series Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure Mode Select Pairing the neohub

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL Style that revolves around you. CEILING FAN OWNER S MANUAL Total fan weight *53 lbs. WEXFORD 11/05 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.

More information

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL REMOTE FLOOD AM PM PHOTO F rh PPM TEMPERATURE HUMIDITY SELECT RUN LAMP START FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP

More information

FiRe mobile-2 Operation Manual

FiRe mobile-2 Operation Manual FiRe mobile-2 Operation Manual P/N 00-3230-505-0003-01 ISS 07JAN15 Copyright Trademarks and patents Manufacturer Version 2015 UTC Fire & Security. All rights reserved. The FiRe mobile-2 name and logo are

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. SYSTEM USER GUIDE SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad. IS THIS A FALSE ALARM? YES NO displays. REAL ALARM If

More information

QuadraTouch Pro Software Manual Dryer Control System

QuadraTouch Pro Software Manual Dryer Control System QuadraTouch Pro Software Manual Dryer Control System Software is constantly changing. Make sure you are up to date with Sukup s newest software. New software and manuals are available for download at:

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

EVAPORATIVE COOLER W

EVAPORATIVE COOLER W EVAPORATIVE COOLER 972-1003-W USER MANUAL INTRODUCTION READ AND SAVE THESE INSTRUTIONS! 1 Thanks for your support and choice of our unique tower fan, in order to help you use the product more conveniently,

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

Installation & Operating Guide

Installation & Operating Guide HOT WATER DISPENSER Installation & Operating Guide Read all instructions thoroughly. Keep this guide for future reference. Proof of purchase is required for Warranty. Staple receipt or proof of purchase

More information

PL-1 Thermostat User s Guide

PL-1 Thermostat User s Guide Table of Contents Introduction... 1 PL-1 Thermostat User s Guide Version 2.0 Firmware Version 2.0 Conventions... 2 Front Panel Layout... 3 Thermostat Modes... 4 Thermostat Mode Programming... 5 Set Point

More information

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved.

Wi-Fi Thermostat. Sensi TM INSTALLATION GUIDE. Models: 1F86U-42WF, UP500W Version: October Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Thermostat INSTALLATION GUIDE Models: 1F86U-42WF, UP500W Version: October 2017 2017 Emerson Electric Co. All rights reserved. CONTENTS Installation guide Downloading the Sensi app 3 Creating

More information

HERMS (Heat Exchanger Recirculating Mash System) Controller

HERMS (Heat Exchanger Recirculating Mash System) Controller HERMS (Heat Exchanger Recirculating Mash System) Controller Your new HERMS controller Thanks for buying your controller from us!!! Your controller is based on two MYPIN TA4 series PID controllers. Unlike

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

CODE ALERT Enterprise Software User Guide

CODE ALERT Enterprise Software User Guide CODE ALERT Enterprise Software User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form

More information

Quick Tips Electronic Temperature Controllers (ETC)

Quick Tips Electronic Temperature Controllers (ETC) Quick Tips Electronic Temperature Controllers (ETC) Electronic Temperature Controllers (ETC) The Ranco ETC is a microprocessor based temperature controller capable of regulating temperatures in both heating

More information

SPRITE Warewash Dispensing System

SPRITE Warewash Dispensing System SPRITE Warewash Dispensing System Reference Manual DM-400 NUMERIC Series Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online for the

More information

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800) Aquapeutics GENERAL INSTALLATION GUIDE Toll Free Customer Service line 1 (800) 290-6812 Thank you for choosing an Aquapeutics product. Please read the following guide in its entirety before assembling

More information

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017

Sensi TM. Touch Wi-Fi Thermostat INSTALLATION GUIDE. Models: 1F95U-42WF, ST75 Version: October 2017 Models: 1F95U-42WF, ST75 Version: October 2017 Sensi TM Touch Wi-Fi Thermostat INSTALLATION GUIDE CONTENTS Installation guide Downloading the Sensi app 3 Creating a Sensi account 3 Installing the Sensi

More information

Grainfather Connect Control Box. Instructions

Grainfather Connect Control Box. Instructions Grainfather Connect Control Box Instructions TECHNICAL SPECIFICATIONS Waterproof graphic display BLUETOOTH WIRELESS TECHNOLOGY (LE V4.1) Triac - FOR ACCURATE HEAT CONTROL (PID ALGORITHM) SYNCS WITH GRAINFATHER

More information

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS L-71 SinkSpa JETTED SINK Model LJD1306L JOB AID Part No. 8178201 FORWARD This Whirlpool Job Aid, SinkSpa Jetted Sink, (Part No. 8178201), provides the

More information

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents. 1 Model: Available in : Sapphire Black and Glacier White Table of Contents Product Image 1 Frost Protection 20 Table of Contents 2 Power ON/OFF 21 What is a Programmable Room Thermostat? Installation Procedure

More information

Code Alert Series 30 Software User Guide

Code Alert Series 30 Software User Guide Code Alert Series 30 Software User Guide 2018 RF Technologies, Inc. All specifications subject to change without notice. All Rights Reserved. No Part of this work may be reproduced or copied in any form

More information

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website General/Operational Troubleshooting Guide I have an Error Code: E0 (Thermostat

More information

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

Dimensions: 39 1/2 w x 22 D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink, Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot), Putty knife Plumber's putty Pipe wrench Channel-lock pliers

More information

USER MANUAL FOR GAS STOVE MODEL TABLE OF CONTENTS. Getting Started What s in the Box

USER MANUAL FOR GAS STOVE MODEL TABLE OF CONTENTS. Getting Started What s in the Box USER MANUAL FOR GAS STOVE MODEL iguardstove INTELLIGENT Model # IGSG-(valve) Sept 2018 Firmware v2048 TABLE OF CONTENTS Open the Box Getting Started What s in the Box Control Panel Quick Install Guide

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Installation and Operation Manual MG-304. Please read this manual carefully before use.

Installation and Operation Manual MG-304. Please read this manual carefully before use. Installation and Operation Manual MG-304 Please read this manual carefully before use. 1 P a g e Important Safety Instructions: Warning! Use this unit only for its intended purposes or as described in

More information

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

Attached is Supplement three for service manual We suggest you file this with your Manual for reference. INTRODUCTION Attached is Supplement three for service manual 16008203. We suggest you file this with your 16008203 Manual for reference. Models covered in this manual: MAH21PD MAH21PN MAH21PR MAH21PS CONTENTS

More information

REV: 000. Lumitron/ Luminator

REV: 000. Lumitron/ Luminator REV: 000 Lumitron/ Luminator Table Of Contents Introduction 3 Standard Operating Guide 3 Features & Specs 3 External Layout 4-8 Internal Layout 9-10 Wiring Diagrams 11 F.A.Q. 12-14 Ballast to Lamp Relationship

More information

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA Smart Smart Garage Garage Hub Hub Manual Manual For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA by Before You Start To reduce the risk of SEVERE INJURY to persons: DO NOT enable the MyQ

More information

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 Model: 1 Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure 1 2 3-4 5-6 Mode Select Pairing the ProTouch iq Hub Pairing the ProTouch iq What

More information

Click here for a labelled version of above

Click here for a labelled version of above Click here for a labelled version of above Download Of This Page: Click Here to download this whole page. (773 Kb Adobe Acrobat File) Biodiesel Processor Diagram: Click Here to download a detailed diagram

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility

More information

Robobrew 35L All In One Brewery with Pump Generation 3 Model: KL04749

Robobrew 35L All In One Brewery with Pump Generation 3 Model: KL04749 Instruction Sheet Robobrew 35L All In One Brewery with Pump Generation 3 Model: KL04749 Page 1 of 22 www.kegland.com.au Last Updated 1/30/2018 8:44 PM WARNING IMPORTANT INFORMATION! 1. Please read this

More information

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Welcome to MultiSight TM Vision Sensor Hands-On Lab Welcome to MultiSight TM Vision Sensor Hands-On Lab About This Hands-On Lab Welcome to the MultiSight TM Vision Sensor Hands-On Lab! This session provides you with an opportunity to explore the functionality

More information

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17 User manual Epi-Care mobile Phone: +45 58 50 05 65 Page 1 of 17 Introduction The purpose of the Epi-Care mobile epilepsy alarm is to ensure severe seizures are not overseen. Epi-Care mobile recognizes

More information

Deluxe FreezeAlarm. Model FA-D2

Deluxe FreezeAlarm. Model FA-D2 Deluxe FreezeAlarm Model FA-D2 Thank you for purchasing our Deluxe FreezeAlarm, model FA-D2. If you have any questions or concerns about this product, feel free to contact us. Our phone number, web sites

More information

MPL3115A2 Sensor Toolbox User s Guide

MPL3115A2 Sensor Toolbox User s Guide Freescale Semiconductor Document Number: MPL3115A2STUG User s Guide Rev. 0, 04/2012 MPL3115A2 Sensor Toolbox User s Guide 1 Introduction The Freescale DEMOSTBMPL3115A2 Sensor Toolbox provides the hardware

More information

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series Model: Available in : Sapphire Black and Glacier White 2 Series Table of Contents Product Image 1 Locking/Unlocking the neostat 19 Table of Contents 2 Frost Protection 20 What is a Programmable Room Thermostat?

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL CEILING FAN OWNER S MANUAL VERA CRUZ 5/04 GENERAL INSTALLATION & OPERATION INSTRUCTIONS IMPORTANT SAFEGUARDS: 1. To ensure the success of the installation, be sure to read the instructions and review the

More information

Installation Instructions

Installation Instructions Instructions for Frontload Washers Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part

More information

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver Product Guide EBDHS-AD-LT30 Ceiling PIR HS presence detector 1-10V, low temperature Overview The EBDHS-AD-LT30 PIR (passive infrared) presence detector provides automatic control of lighting loads with

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

Smart Water Heater Controller

Smart Water Heater Controller Smart Water Heater Controller Installation Instructions Version 1.0 2016 1 Introduction Congratulations on the purchase of your Aquanta Smart Water Heater Controller! The Aquanta retrofittable water heater

More information

Liberty-Classic. Operator s Manual

Liberty-Classic. Operator s Manual Liberty-Classic Operator s Manual Pure & Secure LLC 4120 NW 44th Lincoln, NE 68524 Phone: 402-467-9300 Fax: 402-467-9393 2006, Pure & Secure LLC. All Right Reserved Table of Contents Important Safety

More information

OWNER OPERATION MANUAL FOR USER 2.0

OWNER OPERATION MANUAL FOR USER 2.0 OWNER OPERATION MANUAL FOR USER.0 Contents kumo cloud... Quick Setup... Get Started... Download the App... Create an Account... Control... Whole or Individual Zone... Temperature... Cool, Heat and Other

More information

Installation Instructions

Installation Instructions www.aquanta.io Aquanta by Sunnovations Inc. www.sunnovations.com Installation Instructions For online instructions go to: https://portal.aquanta.io/setup 1 Tools Needed: Phillips screw driver Flathead

More information

STEAMPRO. Steam Generator Troubleshooting and Service Guide

STEAMPRO. Steam Generator Troubleshooting and Service Guide STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.

More information

The FAWSsit USER CARE GUIDE

The FAWSsit USER CARE GUIDE The FAWSsit Fold Away Wheelchair Shower US Patent Number 7,231,673 B1 USER CARE GUIDE Recliner R3000 A Note to You Thank you for buying this product. To ensure you enjoy years of trouble-free operation,

More information

PRODUCT GUIDE. Spike+ System Product Guide CONTENTS:

PRODUCT GUIDE. Spike+ System Product Guide CONTENTS: Spike+ System Product uide ONTNTS: Page : rewing control panel Page : Hot Liquor Tank Page 3: Mash Tun Page : oil Kettle Page 5: Wort hiller Page 6: Pumps Page 7: Hoses RWN ONTROL PANL Autotune your HLT

More information

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08 Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3

More information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs User Manual Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs Models 89800-13 and 89800-14 THE STANDARD IN PRECISION MEASUREMENT Table of Contents

More information

How To: PREPARATION REPLACE A KITCHEN SINK

How To: PREPARATION REPLACE A KITCHEN SINK Skill Level: INTERMEDIATE Give these projects a try if you're a confident DIYer with a good working knowledge of a variety of tools. They can take a day or more to complete. If you can build a birdhouse

More information

HWD-2110 Hot Water Dispenser

HWD-2110 Hot Water Dispenser User s Guide t f Touch Function Selector Technology HWD-2110 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine. Temperature On Demand US design patent applied for. Other

More information

INSTANT HOT WATER DISPENSER

INSTANT HOT WATER DISPENSER INSTANT HOT WATER DISPENSER Tank Installation Materials required (not provided) 2 mounting bracket screws (and 2 plastic anchors if attaching to drywall) Shut-Off valve and T fitting Components When you

More information