1 THE ELW INTEROPERABLE THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER FORM 56.1 REV 0707 SPECIFICALLY DESIGNED FOR INTEROPERABILITY The ELW provides more information about what s happening in the space than any other VAV terminal because it monitors load, supply air temperature and flow at each diffuser. LonMark compatible, the ELW will exchange data with products from other vendors on any LonWorks DDC building control network. Interoperability with other control networks is easy using gateways by other manufacturers. BETTER CONTROL ADAPTIVE ARTIFICIAL INTELLIGENCE Adaptive artificial intelligence enables the ELW to learn the dynamics of any room. During operation the unit continuously updates its control process to give the correct control response. This eliminates field tuning and calibration required by most controllers. It also eliminates inaccuracies seen when room conditions stray from tuned conditions. Adaptive control compensates for mechanical hysteresis too. ONLY THERMA FUSER VAV OFFERS THESE BENEFITS Superior air distribution longer throws, no dumping, more entrainment, even temperature distribution, higher ADPI and better ventilation effectiveness. Lowest cost per DDC zone of control. Lowest energy DDC VAV terminal green VAV. Low to no maintenance. Easily adapts to office changes. Copyright Acutherm 2005
2 NETWORK AND CONFIG URATION VARIABLES For ease of interoperability the ELW uses standard variables similar to the VAV Controller Functional Profile ID:8010 published by the LonMark Interoperability Association. It utilizes the following variables. CONFIGURATION Occupancy Temperature Setpoints Heating and cooling temperature setpoints for various occupancy modes. Location Label or Description Used to provide a descriptive physical location (such as room number). VAV heating/vav cooling or VAV cooling only. Other configuration properties include send heartbeat, maximum receive time and maximum send time. INPUTS Temperature Setpoint Can be changed via the network. Application Mode Change to another mode such as night purge or morning warm up. Manual Override Can be used to open for balancing. Occupancy Command Occupied or Unoccupied. Emergency Command Pressurize or Depressurize. Other inputs include space temperature, flow, energy hold off, CO 2 sensor, duct inlet temperature and setpoint offset. OUTPUTS Air Flow Rate. Space Temperature. Supply Air Temperature Unit Status Combines the operating mode, the capacity of heating and cooling used and an indication of any alarms present. Effective Setpoint Reports effective setpoint when the setpoint is changed locally. Terminal Load Energy use as a function of percentage of maximum flow setting and supply air temperature. THE ELW INTEROPERABLE THERMA FUSER LINEAR VAV DIFFUSER
3 HOW IT WORKS The ELW Therma Fuser linear diffuser has blade damper(s) that open and close to meter air flow (hot or cold) into the room. The damper(s) are modulated by the piston of a thermal actuator. Thermal actuators, used for reliability and low maintenance, have a piston in a cylinder wrapped with a resistance heater. The cylinder is filled with petroleum wax which, when heated by the resistance heater, expands to push out the piston. When heat is stopped the wax rapidly cools and contracts and the piston retracts. The thermal actuator piston is precisely positioned with a variable DC signal to the resistance heater form the DDC controller. The DDC controller with adaptive artificial intelligence has the ability to learn form experience and modify control behavior similar to the reasoning power of the human brain. This adaptive controller controls to setpoint in response to room temperature, supply air temperature and flow. Every 10 seconds it determines if the flow should be adjusted and the amount of any adjustment based on temperature relationships and both the rate and direction of change of flow. SELECTION GUIDELINES Minimum/Maximum Spacing Use the throw ratings for design air volume (maximum flow in the Performance Guide) to determine distances for minimum and maximum spacing to walls and other diffusers. Below design air volume, room air motion will be kept to acceptable levels by the increasing entrainment ratio as the diffuser turns down. Less than 100fpm / 0.51m/s (interpolate) is normally satisfactory for air discharged against an inside partition and up to 150fpm / 0.76m/s can be tolerated against an outside wall. Maximum throw is usually figured around the 50fpm / 0.25m/s point. DISTANCE BELOW THE CEILING Ratings in the Performance Guide are for sidewall diffusers installed with the top edge 2 in./10mm or less below the ceiling. Under these conditions, the distance between the bottom of the 50fpm/.025m/s lobe and the horizontal centerline of the diffuser face is 4 in./100mm for one slot diffuser, 5 in./125mm for two slot diffusers and 10 in./250mm for four slot diffusers. The drops remain the same for installations with the top edge of the diffuser more than 2 in./100mm below the ceiling. Throw reduces as the distance increases between the ceiling and the top edge of the diffuser as show in the following graph. When given a choice, put diffusers in line with one another, not blowing at each other. But when they must, space diffusers at least two times the 150fpm / 0.76m/s throw (preferably two times the 100fpm / 0.51m/s throw) to avoid down drafts. Maximum centerline spacing between diffusers in line (in the same row) should be three to four times the unit s length. A 48in. / 1200mm diffuser would then cover an area 12 to 16 feet / 3650 to 4875 mm wide (maximum). Do not obstruct the venturi outlet at the end of the diffuser. Allow a spacing of 2in. / 50mm or more between the venturi opening at the end of the diffuser and lights, joists, other diffusers, etc. Return Air may be handled in the conventional manner using return air grills or, more typically, return air sidewall slots can be provided to match the supply air diffusers. Each space should have returns. Select returns with the same total length of slot as the supply air diffuser in the space. If return air slots must be located in the supply air stream, place them beyond the 50fpm / 0.25m/s throw for the supply air diffuser.
4 SYSTEM DESIGN The best control for heating/cooling air handling units supplying air to VAV terminals is a discharge sensor or thermostat which maintains constant supply air temperature. With DX equipment these are a high and low limit. The fan should run continuously. The constant discharge velocity of Therma Fuser diffusers at varying air flow provides good room circulation which reduces stratification. Because the Therma Fuser diffusers control room temperature by sensing room air induced up the wall, care should be taken not to disturb room air induction and entrainment. Avoid the possibility of anything, including furniture, below the diffuser which blocks secondary air from entering the induction chamber of the diffuser. Keeping heating supply air temperatures as low as possible will further reduce room air stratification to a negligible level. Static pressure at the inlet of the Therma Fuser diffuser should be between 0.05 wg / 12Pa and 0.25 wg / 62Pa at full and partial air flows. Static pressure below 0.05 wg / 12Pa will result in low air flow and less induction. Above 0.25 wg / 62Pa, Therma Fuser diffusers operate well but excessive noise may result. If the system turns down more than 30%, static pressure should be controlled. Included in the options for static pressure control are fan control and bypass dampers. Zone dampers are recommended where several zones share a higher pressure duct or riser. When designing ducts, if Therma Fuser diffusers are to deliver nominal volume at an inlet static pressure of 0.15 wg / 37Pa and if a maximum static pressure of 0.25 wg / 62Pa is to be held for quiet operation, size the duct for a maximum pressure drop of 0.10 wg / 25Pa between the first and last takeoff. DIMENSIONS
5 A short length of low pressure flexible duct should be used to connect the diffuser. To avoid static pressure losses, flexible duct runs should be designed and installed as straight as possible (equivalent of one 90 turn maximum). Flexible duct connections to all diffusers must provide a straight run of four duct diameters minimum leading to the inlet to help insure effective operation. Acutherm has how to system design brochures for almost every ducted air system. GUIDE SPECIFICATION Interoperable variable air volume linear diffusers shall be Therma Fuser model ELW manufactured by Acutherm, Hayward, CA. Each diffuser shall be a complete VAV terminal with room air thermostat, supply air thermostat, flow sensor(s), adaptive controller, and thermal actuator self contained in a linear diffuser. They shall be LonMark compatible for interoperability on any LonWorks network. The adaptive controller shall have the ability to learn the dynamics of the conditioned space and change control response as the space changes. P, PI, PD and PID control shall not be acceptable. The controller shall be compatible with the LonMark Functional Profile for VAV controllers. It shall provide most network and configuration variables (except the inapplicable internal heater and internal fan control options). The diffuser blades shall be constructed of extruded aluminum with all visible portions painted T Bar off white low gloss enamel. The diffuser shall be complete with plenum constructed of 24 gauge galvanized steel. The diffuser shall have an induction chamber and supply air venturi at one end for inducing room air past the room temperature sensor. The venturi shall be at least 4in. / 100mm wide for effective induction. The VAV diffuser shall have positive induction of secondary room air over the room thermostat at all flows from fully closed to fully open. Manufacturer s ratings for flow and sound shall be verified by an independent testing laboratory certified for ARI 890 and ADC testing. Power compression springs cartridges shall be attached directly to the thermal actuator to contain the forces produced without distorting other parts of the diffuser and assure accuracy of control. Optional The diffuser shall be lined with ½ 2 pound density black bonded blanket of glass fibers with smooth fire resistant air stream surfaces adhered with ASTM C 916 adhesive. Power Requirements: 24VAC +4/ 2VAC. 18VA maximum. Processor: Echelon 3150 Transceiver: Terminations: Operating Environment: Indicators: Free Topology FTT 10 Network: RJ 45 or screw terminals. Power: Screw terminals. Temperature: 13 F/25 C to 131 F/55 C. Humidity: 5 95% relative humidity, non condensing. LED indicators for power and network communications.
6 TWO YEAR WARRANTY Acutherm warrants that its ELW Therma Fuser linear diffusers, exclusive of any options and accessories (whether factory or field installed) shall be free from defective material or workmanship for a period of two (2) years from the date of shipment and agrees to repair or replace, at its option, any parts that fail during said two (2) year period due to any such defects which would not have occurred had reasonable care and proper usage and all parts and controls remain unaltered. Acutherm makes NO WARRANTY OF MERCHANTABILITY OF PRODUCTS OR OF THEIR FITNESS FOR ANY PURPOSE OR ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH EXTENDS BEYOND THE LIMITED WARRANTY ABOVE. ACUTHERM S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM DEFECTS SHALL IN NO EVENT EXCEED THE COST OF REPAIR OR REPLACEMENT OF PARTS FOUND DEFECTIVE UPON EXAMINATION BY ACUTHERM. IN NO EVENT SHALL ACUTHERM BE LIABLE FOR INCIDENTAL, INDIRECT OR CONSEQUENTIONAL DAMAGES OR DAMAGES FOR INJURY TO PERSONS OR PROPERTY. Acutherm shall not be responsible for freight to or from its plant in connection with the inspection, repair or replacement of parts under the terms of this limited warranty nor for cost of removal or installation Sabre Street Hayward, CA Tel: (510) Subject to change without notice. Fax: (510) FORM 56.1 REV 0707 Supersedes Nothing e mail: info@acutherm.com
TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser
TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser Therma-Fuser Systems Models: TLW-C VAV cooling only TLW-CW VAV cooling with constant volume warm up TLW-D Manually adjustable blades TLW-RAD
More informationMB Therma-Fuser Standalone Motorized Disc VAV Diffuser
MB Therma-Fuser Standalone Motorized Disc VAV Diffuser Models: MB-M MB-S MB-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser
More informationMBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser
MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser Models: MBS-M MBS-S MBS-D Master with sensor and controller Slave with controller to follow master Drone with controller for 3rd party control Therma-Fuser
More informationTherma-Fuser Square Thermally Powered VAV Diffuser
ST Therma-Fuser Square Thermally Powered VAV Diffuser Therma-Fuser Systems Models: ST-HC Separate set points for VAV heating and VAV cooling ST-C One set point for VAV cooling only ST: Product Overview
More informationINSTALLATION & OPERATIONS MANUAL
FORM 051.201 REV1208 THERMA-FUSER SYSTEMS SQUARE 1 x 1 / 300mm - THERMALLY POWERED VAV DIFFUSER INSTALLATION & OPERATIONS MANUAL Models: TK-C TK-D TK-RA VAV cooling and VAV heating VAV cooling only Manually
More informationINSTALLATION, BALANCING & MAINTENANCE
FORM 10.2 REV 0510 THERMA-FUSER THERMALLY POWERED VAV DIFFUSER INSTALLATION, BALANCING & MAINTENANCE MODULAR VAV SYSTEMS Models: ST-C VAV cooling only. ST-HC VAV cooling and VAV heating. (See Fig. 1 for
More informationGrilles & Diffusers - Metal
Therma-Fuser Product Code Face Size Metric Inlet Designation Imperial 16040 595 x 595 6 16041 595 x 595 8 16042 595 x 595 10 16043 595 x 595 12 Grilles are white. Therma-Fuser is thermal vav diffuser with
More informationINSTALLATION, BALANCING & MAINTENANCE
FORM 23.2 REV 0605 THERMA-FUSER THERMALLY POWERED VAV DIFFUSER INSTALLATION, BALANING & MAINTENANE MODULAR VAV SYSTEMS SIDE MODELS: TLW- TLW-W VAV cooling only VAV cooling and warm up (constant volume
More informationDESIGNING MODULAR VAV SYSTEMS
FORM 5.2 REV 0905 THERMA-FUSER THERMALLY POWERED VAV DIFFUSER DESIGNING MODULAR VAV SYSTEMS MODULAR VAV SYSTEMS The Therma-Fuser diffuser is a simple stand alone device that provides VAV control when supplied
More informationEngineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.
VAV Diffusers lease refer to the rice Engineer s HVAC Handbook for more information on VAV Diffusers. Diffuser Types Ceiling Diffusers Conventional air distribution systems typically group several rooms
More information80-6-ISD A Better Solution for Proper Space Air Distribution
Air Handling Systems Engineering & Technical Bulletin 80-6-ISD A Better Solution for Proper Space Air Distribution In designing an HVAC system, an engineer has the following goals: 1. True building load
More informationARE BETTER THAN VAV BOXES Lowest energy VAV terminal Easily adapts to office layout change Lowest cost per zone of control
S FORM 2.1/402 HRMA-FUSR VAV MODULS AR BR HAN VAV BOXS Lowest energy VAV terminal asily adapts to office layout change Lowest cost per zone of control Superior air distribution Low to no maintenance ystems
More informationInffusers. idl20 (2 WAY) ids60 (4 WAY)
Inffusers idl20 (2 WAY) ids60 (4 WAY) built on innovation what is an inffuser? DADANCO s INFFUSERS are quite simply an induction diffuser that uses special nozzles located in the underside of the air plenum
More informationLinear Floor Heaters
Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement
More informationPerformance Aire offers three VAV comfort solution packages.
The Problem Overheating or overcooling problem areas? As heating and cooling zones grow larger budget constraints cause multiple work spaces to be controlled by a single thermostat. This causes system
More informationModular Heating & Ventilating Unit Model IGX-HV
Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit
More informationGuide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:
Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT
More informationTTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity
Introduction is a ceiling mounted supply air diffuser with integrated electronics for demand control of airflow and climate control. is designed for the lowest possible energy usage without deviating from
More informationImproved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design
Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design Technical Paper A guide to the design of an effective low pressure VAV air distribution system By Noel de Villiers Pr.
More informationFAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design
FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationASHRAE JOURNAL ON REHEAT
Page: 1 of 7 ASHRAE JOURNAL ON REHEAT Dan Int-Hout Chief Engineer Page: 2 of 7 Overhead Heating: A lost art. March 2007 ASHRAE Journal Article Dan Int-Hout Chief Engineer, Krueger VAV terminals provide
More informationQuestions??????? Thank you
Questions??????? Thank you Sustainable Design Products and Systems Dan Hahne/Eric Dowell ASP Sustainable Designs Overview Price and Uponor Hydronic Heating and Cooling Price Displacement Ventilation Price
More informationDisplacement Ventilation
Displacement Ventilation Displacement Ventilation Displacement Ventilation vs. Dilution Ventilation Characteristics Design Considerations Layout and Selection Product Overview Casino Case Study Dilution
More informationChilled Water DOAS Fan Powered Terminal Units
Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction
More informationIDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions
IDL20e (2 way discharge) IDS60e ( way discharge) Frequently Asked Questions UDI (vertical discharge) Inffusers INFFUSER FREQUENTLY ASKED QUESTIONS The following are frequently asked questions (FAQ s) on
More informationA. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.
Section 15 _ Energy Recovery Air Handling System Part 1: GENERAL 1.1 Section Includes: A. Energy Recovery Air Handler B. Controls (most by Others) C. Equipment Schedule 1.2 Related Sections: A. Section
More informationRosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS
10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional
More informationUNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS
PART 1 - GENERAL 1.01 General: A. Laboratory ventilation system will ensure the health and safety of laboratory occupants. B. Room pressurization control will utilize airflow tracking to vary the volume
More informationTTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity
Introduction is a ceiling mounted supply air device with integrated electronics for room climate control. The design allows for a maintained high injection rate and thus mixing of room air even at low
More informationHAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001
This HAP e-help provides a high-level overview of induction beams, how they work and how to model them in HAP 4.8 (and later versions). The first half of the article explains how induction beams work.
More informationCLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME LINEAR CEILING DIFFUSER 12 CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL
More informationTEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application Application Note Building Technologies
TEC Controller VAV 0-10V Fan Control with Hot Water Heat, Application 2236 Application Note 140-1228 Building Technologies Table of Contents Overview... 4 Hardware Inputs... 10 Hardware Outputs... 10
More informationThe swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.
Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush
More informationphoto by PFC Price Fan Column
photo by www.mrobinsonphoto.com PFC Price Fan Column Typical Applications The Price Fan Column (PFC) is a vertical fan unit designed to discharge into a raised access floor plenum. The unit s compact design
More informationIC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 ICS6-MB, ICS8-MB
Beale Street Audio IC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 In Ceiling Speakers ICS6-MB, ICS8-MB In Ceiling Subwoofers Installation Guide Introduction Congratulations
More informationVCD,VRD,VSD 4/5 GREEN TEMPERATURE OFFSET FOR WINTER HEATING AND COOLING CHANGEOVER MECHANICAL THERMAL MECHANISM
THERMAL VARIABLE VOLUME CEILING DIFFUSER 6 VCD,VRD,VSD 4/5 GREEN TEMPERATURE OFFSET FOR WINTER HEATING AND COOLING CHANGEOVER EXCELLENT THROW & FLOW MECHANICAL THERMAL MECHANISM LOW NOISE HIGH INDUCTION
More informationCopyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services
Page 238216-1 Copyright 2003 and 2005 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified by MSU Physical
More informationCity of Duluth Festival Center 04/25
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationThe Future In Air Distribution
The Future In Air Distribution 2nd Edition Drury College proved to be an excellent testing ground for Thermal Core cold air diffusers since the structure offered a variety of room configurations. At left,
More informationADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM
ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT February 29, 2012 RFP NO: 17 PROJECT: Josephine County Justice Center HVAC Upgrades BID CLOSING DATE: NO CHANGE: March 8, 2012 / NOT LATER
More informationSwegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES
Swegon PACIFIC Integrated chilled beam PACIFIC CHILLED BEAM The PACIFIC is a high performance chilled beam for installation in false ceilings. Built-in flexibility, designed to meet the needs of today
More informationProduct Data. Features/Benefits. 33CS Carrier Comfort System Variable Volume and Temperature (VVT )
Product Data 33CS Carrier Comfort System Variable Volume and Temperature (VVT ) The VVT Comfort System provides the following features and benefits: 365-day scheduling, daylight savings compensation, and
More informationGuardian CR2000 Overhead Ionizing Air Blower. User s Manual
Guardian CR2000 Overhead Ionizing Air Blower User s Manual Tabel of Contents SECTION 1: Description SECTION 2: Safety SECTION 3: Features SECTION 4: Specifications SECTION 5: Installation SECTION 6: Operation
More informationSINGLE DUCT TERMINAL UNITS
Performance Data AHRI Certification and Performance Notes Model Series 3000 asic Unit AHRI Certification Rating Points VAV: Fiberglass Inlet Size Airflow cfm l/s Min. Inlet Ps w.g. Pa Discharge Sound Power
More informationSECTION AIR DUCT ACCESSORIES
SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control
More informationCAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS
CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS TABLE OF CONTENTS Introduction...3 Selection & Application.....4 Selection Examples......5-6 Ratings......7-8 Correction Factors......9-10
More informationA. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.
SECTION 15622 DIRECT GAS-FIRED BURNER & MANIFOLD SYSTEM PART 1: GENERAL 1.1 Section includes: A. Direct gas-fired heater modules B. Controls C. Equipment schedule 1.2 Related Sections A. Section 01655:
More information- Essay Control Functions and Benefits
- Essay Control Functions and Benefits E 005 07/01 A hydronic heating control system performs many complex and important functions. Each of these functions provide benefits that make the system comfortable,
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationProduct Data. Features/Benefits. AirManager Control. 33AM Comfort System
Product Data 33AM Comfort System AirManager Control CV CONTROL BOX VAV CONTROL BOX AirManager brings precise, intelligent control to your air handler operating component and function needs, including:
More informationWhat is a High Velocity System?
What is a High Velocity System? What s different? Original concept introduced in 1946 for heat in aircraft High Velocity Systems utilize two or three inch outlets and distribution tubes to deliver the
More information15900 HVAC INSTRUMENTATION AND CONTROLS
15900 HVAC INSTRUMENTATION AND CONTROLS PART 1 GENERAL - Andover Controls BAS system is the standard for the University, and may be specified as a proprietary item. 1.0 RELATED DOCUMENTS A. Drawings and
More informationModel 405 AIRGARD Fume Hood Monitor
INSTALLATION AND MAINTENANCE INSTRUCTIONS Model 405 AIRGARD Fume Hood Monitor A TSI Company Model 405 AIRGARD Fume Hood Monitor Specifications Instrument Dimensions Instrument Weight Shipping Weight Green
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationQAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR
QAS-10000 SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR INSTALLATION, OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749, RICHMOND, ONTARIO, CANADA. K0A
More informationSECTION DUCTWORK
PART 1 GENERAL 1.1 REFERENCES SECTION 23 31 00 DUCTWORK A. ASHRAE - Handbook, Duct Design B. ASHRAE - Handbook, Duct Construction C. ASTM A90/A90M - Standard Test Method for Weight (Mass) of Coating on
More informationMODEL CDB8 INSTALLATION INSTRUCTIONS
REV 0417 TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com SUITABLE FOR SIDE WALL OR
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
Objectives and Requirements For the Creative and Performing Arts High School (CAPA), the main objective of the mechanical design is to provide an energy efficient system that is easily maintainable and
More informationIndirect Gas-Fired Make-Up Air
Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up
More informationM Series Fan Filter Units
M Series Fan Filter Units Product Specifications... 2 Safety Instructions... 3 Receiving and Unpacking... 3 Pre-Installation Instructions... 3-4 Installation Instructions... 4 Electrical Installation Instructions...
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More informationFORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units
FORM 100.50-EG2 (502) TM FlexSys Configured Packaged Rooftop Air Conditioning Units TABLE OF CONTENTS PAGE TOTAL INTEGRATED HVAC SYSTEM... 3 AN INTEGRATED SOLUTION... 4 INTRODUCTION... 6 System Description...
More information45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:
SMAT ZONE TM VAV Electronic Diffusers SMAT ZONETM www.smartdiffuser.com SMAT ZONE SE-HC/M, Type LT, Lay-in, T-Bar, VAV Fully Modulating Diffuser Specifications APPLICATION: The Model SE-HC/M VAV Smart
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationBARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide
BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner
More informationPlease Read and Save These Instructions.
Page 1 of 8 RadonAway Ward Hill, MA. GP500 Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE
More informationMacroAir by Blue Giant AirVolution HVLS Fans
Manufacturer: MacroAir Technologies, Inc. 794 South Allen Street San Bernardino, CA 92408-2210 Macroairfans.com SECTION 15830 INDUSTRIAL/COMMERCIAL CEILING FANS PART 1 GENERAL MacroAir by Blue Giant AirVolution
More informationInstallation & Maintenance Instructions
PRH Series Plenum Heaters Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise
More informationSelected Laboratory Energy Efficiency Measures
Selected Laboratory Energy Efficiency Measures These are some of the most effective energy efficiency measures for laboratories 1. Reduce (optimize) air changes per hour in lab space 2. Design to the proper
More informationIN020 Rev F Page 1 of 8
IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationBACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657
BACnet PTEC Controller VAV 0 to 10V Series Fan and 3- Stage Electric Heat, Application 6657 140-1158 Building Technologies Table of Contents Overview... 5 BACnet 14 Hardware Inputs... 14 Room Unit Identification...
More informationBypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS
BYPASS TERMINAL UNITS DVAC, One Of The Premium Workshops Specialized in Duct Fabrication has Executed Several Projects (Residential, Governmental, Commercial, Industrial & Institutional). 2 BYPASS TERMINAL
More informationDESCRIPTION OF TECHNOLOGY
March 2009 Underfloor Air Distribution INTRODUCTION Copyright 2009 Glumac. All rights reserved. While this Green Paper discusses primarily the use of raised access floors for air distribution, HVAC integration
More informationSERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB
SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB TROX (U.K.) LTD CAXTON WAY GB-THETFORD NORFOLK IP24 3SQ TEL: 01842 754545 CONTENTS 1. INTRODUCTION 1. 1 DESCRIPTION 1.2 PACKAGING AND STORAGE 1.3 HANDLING
More informationZoning System Design Manual
Zoning Made Effortless 70-2321-03 Introduction The Concept of Zoning The basic principle of forced air zoning is to allow one HVAC system to be controlled by multiple thermostats, heating and cooling a
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationUFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas
UFAD and Displacement Ventilation Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas UFAD and DV Systems, Objectives: Understand Differences between: Well Mixed, Partially Stratified and Fully
More informationVX SERIES Wireless Thermostat with Occupancy Sensor
VX SERIES Wireless Thermostat with Occupancy Sensor INSTRUCTION MANUAL Table of Contents Thermostat Installation... 7 Installing the Wireless Control Card...8 Mounting the thermostat to the wall...9 Thermostat
More informationUNDERFLOOR PRODUCTS E3
UNDERFLOOR PRODUCTS E3 Introduction Introduction Changes in office space usage, sustainable design, and indoor air quality issues have sparked considerable interest in the application of supplying conditioned
More informationSpace Air Diffusion II
MEBS6008 Environmental Services II http://me.hku.hk/bse/mebs6008/ Space Air Diffusion II Ir. Dr. Sam C. M. Hui Visiting Assistant Professor Department of Mechanical Engineering The University of Hong Kong
More informationSECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL
SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationElectric Coils. Blower Coils. Product Information
Product Information General Information Electric heat coils are an available accessory for use with Price blower coil units. The electric heating coils have been specific ally designed to suit Price blower
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.
Page 238219-1 SECTION 238219 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade and square diffuser face Horizontal swirling air discharge For comfort zones, with fixed air control blades Circular and
More informationCONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER
ELECTRONIC VARIABLE VOLUME LINEAR DIFFUSER 4 VLN 1 CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER ENERGY
More information7400-Series Small Indirect-Fired Air Turnover Units For Heating and/or Cooling Applications Industry-Leading 85% Efficient Burner Exceeds market benchmarks for drum-and-tube indirect-fired air turnover
More informationPredator Controller Hardware Family
Predator Controller Hardware Family Figure1: Predator Controller Only. Figure 2: Predator VAV Actuator. The LONMARK certified configurable Predator Controller provides direct digital control of a variety
More information8+* Bulletin No November 1997
ENGINEERING DATA VALUE 80Z UP-FLOW/HORIZONTAL GAS FURNACES *80.0 to 80.5% A.F.U.E. 45,000 to 20,000 Btuh (3.2 to 32.2 kw) Input Heating Capacity -/2 thru 6 Tons (3.5 thru 2. kw) Nominal Add-on Cooling
More informationInstallation Guide. FCU4 Fan Coil Unit. Self-Contained Interoperable Controller Model UCP-1 for Software Version 3
Installation Guide 502-037-3 FCU4 Fan Coil Unit Self-Contained Interoperable Controller Model UCP-1 for Software Version 3 SUPERSEDES: July 18, 2013 EFFECTIVE: December 9, 2013 Plant ID: 001-4059 SPECIFICATIONS
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade (optional) Horizontal swirling air discharge With very low sound power level for comfort zones, with fixed air control blades
More informationcontrol sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals
control sequences Table 47: QST / EST Analog Electronic Control Strategies Control Package Number QST EST FS-A-5000 FSE-A-5000 FS-A-5001 FSE-A-5001 FS-A-5002 FSE-A-5002 FS-A-5003 FSE-A-5003 FS-A-5004 FSE-A-5004
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More information1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.
SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationHeat Recovery Units. Heat Recovery 1
Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air
More information