BULLETIN G-99. March 2005 CONDENSED CATALOG. Air Moving Products

Size: px
Start display at page:

Download "BULLETIN G-99. March 2005 CONDENSED CATALOG. Air Moving Products"

Transcription

1 BULLETIN G-99 March 2005 CONDENSED CATALOG Air Moving Products

2 Aerovent History Over 75 Years of Growth A brief history of Aerovent includes: the first Aerovent fan manufactured in 1926 by Piqua Electric Manufacturing Co., the development of the Macheta airfoil blade and involvement in forming the Propeller Fan Manufacturer s Association (PFMA) later merging with the NAFM which is now known as AMCA, Aerovent s expansion in the late 60 s and early 70 s with the advent of air make-up equipment, and its entry into the centrifugal fan field in the mid-70 s. Today, Aerovent has become a name synonymous with quality air handling equipment for all phases of industry. Our products are sold by over 400 sales representatives in 80 offices throughout the world. Primary Business Aerovent builds a wide variety of equipment from propellers to complete Air Make-Up systems but our primary business is the manufacture of heavy duty industrial propeller fans. We are one of the fastest growing manufacturers of industrial air moving equipment in the country. We believe this is due to an unbeatable combination of the fans we manufacture and the can do attitude of Aerovent people. Our products are top-of-the-line, tested, consistent, and reliable. Our people will deal with you directly and honestly. They are innovative, have technical expertise, and answers to your problems. Testing Lab Aerovent s headquarters in Minneapolis, Minnesota, contains a 10,000 square foot, state-of-the-art airflow and acoustics testing facility is used for quality assurance and research and development. It is maintained as an AMCA Registered Laboratory and specializes in testing Axial Fans, Mixed Flow Fans, and Centrifugal Fans and Blowers. All fans can be tested on either the fan s inlet or outlet. Photo 1928: Piqua Electric Manufacturing Co. has Aerovent Ring Fans ready for delivery. Manufacturing Capability Aerovent s primary manufacturing site sprawls over 145,000 square feet in Aberdeen, South Dakota. We also have sites in Mitchell, Elkton and Brookings, South Dakota, as well as Vandalia, Ohio. Our facilities utilize Aerovent s state-of-the-art equipment and innovative manufacturing processes but it is the people who work here their skill, their knowledge, and their commitment to build the best fans in the world who make Aerovent a leader in the industry. Fan Selector Program Aerovent offers its new AMCA licensed, Windows -based Fan Selector Program on CD-ROM. Simply enter the required fan type and performance, and the program displays quick and accurate fan selection options that can be easily evaluated based on: fan type, size, class of construction, blade angle, percent of peak, RPM, BHP, outlet velocity, static efficiency, mechanical efficiency, sound power, sound pressure, LwA, and relative costs. Fan accessories can be quickly chosen from an electronic menu, and detailed reports can be printed such as performance data sheets, fan curves, and dimensional drawings. Fan Selector Standard Fan Curve (example) Ship-Out-of-Stock Program Aerovent s Ship-Out-of-Stock (S.O.S) program allows standard fans and accessories to be shipped within 48 hours. Our Ten Day Priority Shipment Program is available to provide built-to-order fans. See Bulletin S-30 or contact your Aerovent representative for information on fans available through these programs. Contents Panel & Ring Fans... 3 Tubeaxial Fans Vaneaxial Fans... 4 Mancoolers... 5 Large Adjustable Pitch Propellers Centaxial Fans... 5 Centrifugal Blowers Fan Selector Dimensional Drawing (example) Roof Ventilators Filtered Units... 9 Fiberglass Fans Air Make-Up...11 Door Air Heater...11 Air Coolers Aerovent Bulletin G-99

3 PANEL & RING Fans Panel and Ring Fans Bulletin 168 Model DDP Direct Drive Panel Fan Model DDR Direct Drive Ring Fan Aerovent panel and ring fans feature the Macheta tipped airfoil blades for increased performance. Available in direct drive and belted; standard, reverse, and reversible airflow. The wide variety of sizes and performances available makes it possible to select fans to match performance requirements and existing wall opening dimensions. Panel Fans permit installation in any square opening with minimum effort and expense. Sizes 9" to 72", capacities to 89,100 CFM. Fiberglass version available: See Model FDP, Bulletin 185, page 6. Ring Fans for general ventilating, cooling, drying, air supply, or exhaust. Sizes 9" to 96", capacities to 131,000 CFM. Belted Fans offer performance flexibility. Fan speed can be adjusted by changing drive configuration. Direct Drive Fans require less maintenance due to a minimum of moving parts. (Motor Side View) Split Wire Guard Reversible Panel & Ring Fans give equal performance in either airflow direction. The reversible R6 blade design is a truly reversible cast aluminum propeller capable of moving the same volume of air at the same brake horsepower requirements in either airflow direction. Remote fan direction control. Direct drive and belted models. Sizes 24" to 96", capacities to 130,300 CFM. Tubeaxial / VANEAXIAL Fans Tubeaxial Fans Models TA, TABD Bulletin 157 Model BP Belted Panel Fan Model DDR Direct Drive Ring Fan With Round Model DDPRV Direct Drive Reversible Panel Fan Adjustable Pitch Medium Pressure Tubeaxial Models ATA, ATABD Bulletin 400 Model TA Direct Drive Tubeaxial Model TABD Belt Driven Tubeaxial Models TA & TABD feature the Macheta tipped cast aluminum airfoil blade for increased performance, and a continuously welded, heavy-gauge flanged casing with bolt holes for mounting to fan accessories or ductwork. Belt Driven for handling corrosive fumes, smoke, hot or moist air. Sizes 12" to 96", capacities to 131,900 CFM, temperatures to 600 F. Direct Drive for relatively clean air applications which permit location of motor in the airstream. Sizes 12" to 96", capacities to 132,500 CFM. Model ATABD Model ATA Belt Driven Tubeaxial Direct Drive Tubeaxial Adjustable pitch airfoil axial flow fans. Unique blade design maximizes energy transfer to the airstream with minimum noise. Blade pitch can be individually manually adjusted. Utilizes a unique cast iron housing containing both bearings and the fan shaft as one assembly. Belt Driven design for applications handling corrosive or hazardous fumes, or dirt-laden, hot, or moist air. Sizes 40cm to 125cm, capacities to 65,100 CFM, pressures to 2 1 2" SP. Direct Drive for clean air applications which permit the location of the motor in the airstream. Sizes 35cm to 125cm, capacities to 75,600 CFM, pressures to 4 1 2" SP. Aerovent Bulletin G-99 3

4 Tubeaxial / VANEAXIAL Fans Type P Tubeaxial/Vaneaxial Models PTA/PTABD, VP/VPBD Bulletin 414 Type W Vaneaxial Models VW, VWBD Bulletin 456 Model VWBD Belt Driven Vaneaxial Model VPBD Model PTA Belt Driven Vaneaxial Direct Drive Tubeaxial Handles a wide range of requirements, from general ventilation to process air supply. Offers mounting flexibility. Model VP/VPBD: Sizes 12" to 60", capacities to 103,000 CFM, pressures to 7" SP. Direct Drive: Sizes 12" to 60", capacities to 96,000 CFM, pressures to 5" SP. Type T Belt Driven Tubeaxial/Vaneaxial Models TTABD, VTBD Bulletin 424 For high capacity straight-line discharge. Blade pitch is manually adjustable with no special tools required. Belt Driven: Sizes 25" to 84", capacities to 211,000 CFM, pressures to 4" SP. Direct Drive: Sizes 18" to 84", capacities to 217,100 CFM, pressures to 4" SP. Axico Anti-Stall Models FPAC, FPMC, FPDA Bulletin FA-200 Model FPAC Axico Anti-Stall Model TTABD Belt Driven Tubeaxial Vane Section (for Model VTBD) Medium pressure tubeaxial. Convertible to a higher pressure vaneaxial by attaching a vane section to the discharge. Available construction for airstream temperatures to 600 F. Fiberglass version available: see Model VTFBD, Bulletin 185, page 6. Model TTABD Tubeaxial: Sizes 12" to 60", capacities to 83,100 CFM, pressures to 3 1 2" SP. Model VTBD Vaneaxial: Sizes 12" to 60", capacities to 81,600 CFM, pressures to 4 1 2" SP. Type B Vaneaxial Models VB, VBBD Bulletin 466 The Axico Anti-Stall is a vaneaxial fan with 100% stable operation. It has no stall area and no stall limit. Features controllable pitch in motion and adjustable pitch at rest. Sizes 32" to 79", performance rated to 250,000 CFM, pressures to 12" SP. Axiad II Model FTFA Bulletin FA-300 Model VBBD Belt Driven Vaneaxial Designed for higher static pressures. Alternate flow design available for high temperature applications, paint spray booths, corrosive or contaminated air. Belt Driven: Sizes 12" to 60", capacities to 108,500 CFM, pressures to 7.5" SP. Direct Drive: Sizes 24" to 48", capacities to 59,500 CFM, pressures to 4" SP. Model FTFA Axiad II Low noise adjustable pitch axial flow fan with high efficiency, compact size, and simple adjustment. Low sound power levels and smaller and lighter weight compared to other standard axial flow and centrifugal fans. Sizes 22" to 55", capacities to 115,000 CFM, pressures to 15" SP. 4 Aerovent Bulletin G-99

5 Mancoolers Mancoolers Models UM, PUM, 39, STL Bulletin 264 Model UM Model PUM Model 39 Model STL Utility Mancooler Pedestal Mount Mancooler Steeler Mancooler Utility Mancooler, Pedestal Mount, and Model 39 feature Macheta airfoil propellers, propeller and motor side safety guards, and a heavy-duty tubular base. Available in sizes 16" to 42", capacities to 35,750 CFM. Large Adjustable Pitch Propellers Steeler Mancoolers offer the same performance as the Utility Mancoolers but fabricated using welded angle construction to withstand rough handling. Constructed of heavier gauge metal and structural angle iron, equipped with steel wheels and lifting eye. Sizes 24" to 48", capacities to 46,200 CFM. Large Adjustable Propellers Model AHX Bulletin 524 Model AHX Adjustable Pitch Propeller Centaxial Fans Centaxial Tubular Centrifugal Fans Model CDD (Direct Drive) Bulletin 337-D Model CBD (Belt Driven) Adjustable-pitch Macheta tipped airfoil blade propellers for coil coolers, cooling towers and heat exchangers, industrial ventilation and process exhaust wherever it is necessary to move large volumes of air. Available in 4 or 6 blade assemblies with angle settings to cover a wide range of performances. All aluminum construction, sizes 54" to 144". Tip speeds to 15,000 FPM, capacities to 328,600 CFM. Adjustable OEM Propellers Model AHX-E Flyer AHX-E Model AHX-E Adjustable Pitch OEM Propeller Available in 4 or 8 blade assemblies. All aluminum construction, sizes 14" to 48". Tip speeds to 18,000 FPM, capacities to 50,000 CFM. BIA Wheel Model CBD Belt Driven Centaxial Aerovent s Centaxial fans combine the advantages of axial flow fans with the performance and application characteristics of centrifugal fans. Used for industrial space and fume ventilation, air make-up, air conditioning, and heat recovery systems. Straight-through airflow, compact design, stable performance, quiet operation, low operating cost. Backward inclined airfoil, non-overloading wheel. Available in Class I, II, and III construction. Belt Driven: Sizes 12" to 71", capacities to 130,600 CFM, pressures to 14" SP. Direct Drive: Sizes 12" to 44", capacities to 50,644 CFM, pressures to 7" SP. Aerovent Bulletin G-99 5

6 Centrifugal Blowers Backward Inclined BI & BIA Industrial SWSI Centrifugal Fans Bulletin 719 DWDI Backward Inclined Airfoil Industrial Centrifugal Fans Bulletin 724 Model BIA SWSI Centrifugal Fan Model BIA DWDI Centrifugal Fan Efficiently designed backward inclined wheels for air moving and fume removal applications. Lower noise level, energy saving operation. Available with Flat Blade (BI) or Airfoil Blade (BIA). Class I, II, III, and IV construction, Arrangements 1, 2, 3, 4, 7, 8, 9, and 10. Temperature range from -40 F to 600 F. Sizes 12" to 79", capacities to 215,700 CFM, pressures to 20" SP. Fiberglass version available: see Model SWCBF, Bulletin 743, page 10. DWDI fans with backward inclined airfoil blades for industrial ventilation. Quiet operation and high working efficiency for clean dry air service. Class I, II, and III construction. Sizes 12" to 79", capacities to 322,250 CFM, pressures to 14" SP. Plug Fan Model CPF Bulletin 751 Utility Blowers Models BIUB, FCUB Bulletin 760 Model CPF Belt Driven Plug Fan Model BIUB Utility Blower Model FCUB Utility Blower Backward Inclined (BIUB) and Forward Curved (FCUB) Utility Blowers. Designed to supply and exhaust air in hospitals, hotels, schools, and fume hoods. Sizes 12" to 36". Available in Class I or II construction with full AMCA Class Rated performance. Class I BIUB fans are listed under UL 705 and Canadian UL 705. Capacities to 29,100 CFM, pressures to 8" SP, temperatures to 600 F. For applications where the fan becomes an integral part of an oven, spray booth, dryer, dust collector, or kiln. Belt driven, available with backward inclined (BI) or optional backward inclined airfoil (BIA) wheel. Construction for temperatures to 275 F, 450 F, and 750 F. Sizes 12" to 39", capacities to 46,500 CFM, pressures to 8" SP. Plenum Fan Model CPN-BIA Bulletin 751 Model CPN-BIA Plenum Fan Plenum fans are used in field-fabricated or factory-built air handling units to pressurize the entire surrounding air plenum. The plenum fan design also saves space by eliminating the fan housing, transitions and diffusers within the air handling unit. Features a backward inclined airfoil (BIA) wheel in sizes 12" to 79", capacities to 150,000 CFM and pressures to 12" SP. 6 Aerovent Bulletin G-99

7 Centrifugal Blowers Industrial Exhaust Fans Model MH Bulletin 705 Series 14 High Pressure Blower Model HPB Bulletin 912 Model MH Industrial Exhaust Fan Model HPB Series 14 High Pressure Blower Radial blade centrifugal fans for conveying production materials or waste, or removal of industrial dusts, fumes and gases. Available in Standard & Heavy Duty construction, Arrangements 1, 8, 9, and 10, in three wheel types: Back Plate Radial Wheel (Model MH-BW), Air Wheel (Model MH-AW), Open Wheel (Model MH-OW). Temperature range from 40 F to 600 F. Sizes 12" to 79", capacities to 80,250 CFM, pressures to 30" SP. Pressure Blower Model PB Bulletin 904 Durable, compact, and versatile. Designed and built for continuous duty in high pressure applications such as agitation and aeration, product cooling and drying, gas boosting and compressing, methane gas removal (landfills) and transporting solid materials. Sizes 14" to 30", outlet sizes 4" to 12", capacities to 6,500 CFM, pressures to 69" SP. Fiberglass version available: see Model HPBF, page 10. Cast Iron Pressure Blower Model CPB Bulletin 920 Model CPB Cast Iron Pressure Blower Model PB Pressure Blower For supplying medium pressure air for cooling, ventilating or exhaust systems handling dust, materials or fumes. Available to 600 F construction. Belt Driven: Sizes 8" to 12", capacities to 1,275 CFM, pressures to 10" SP. Direct Drive: Sizes 8" to 12", capacities to 1,645 CFM, pressures to 8" SP. Cast Aluminum Pressure Blower Model CA/CABD Bulletin 916 Model CABD Cast Aluminum Pressure Blower Medium pressure for cooling, ventilating, and exhaust systems which handle dust, materials, or corrosive fumes. Cast iron housing, cast aluminum wheel. Available to 250 F construction. Belt Driven: Sizes 7" to 14", capacities to 2,180 CFM, pressures to 12" SP. Direct Drive: Sizes 7" to 14", capacities to 2,000 CFM, pressures to 12" SP. Perfect choice for providing low volume, high pressure air for cooling, ventilating and exhaust systems that handle dust, materials or corrosive fumes. Feature heavy duty cast aluminum housings with cast aluminum wheels for extra long life and trouble-free service. Belt Driven: 8" to 18" housing sizes, 4" to 8" inlet diameters, capacities to 2,400 CFM, pressures to 22" SP. Direct Drive: 8" to 18" housing sizes, 4" to 10" inlet diameters, capacities to 2,800 CFM, pressures to 20" SP. Aerovent Bulletin G-99 7

8 Roof Ventilators Upblast Axial Roof Ventilator Model BD40C Bulletin 616 Tu-WAY Roof Ventilator Models TW, TWB, TWBD Bulletin 615 Model BD40C Upblast Axial Roof Ventilator Model TW Tu-WAY Roof Ventilator Versatile, high discharge unit. Tall design discharges smoke and/or fumes high above rooflines and away from surrounding ventilation systems. Three part assembly consisting of stack cap, fan section and base. Features cast aluminum Macheta airfoil blade propeller. Optional spark resistant, corrosion resistant, and 600 F construction. Direct drive and belt driven, sizes 12" to 96", capacities to 123,700 CFM. Upblast and Hooded Propeller Roof Ventilators Model 53 Bulletin 625 Patented reversible propeller design is equally efficient and moves the same amount of air in either supply or exhaust direction. For clean air applications. Economical and versatile. Floor level control. Available in direct drive, belt driven and belted. Sizes 24" to 72", capacities to 88,900 CFM. Three-Way Heat Saver/Ventilator Models RRES, RREH Bulletin 673 Upblast Models D53, B53 Model RREH Three-Way Heat Saver/Ventilator Hooded Models HD53, HB53 High capacity, heavy duty, quiet and efficient upblast exhaust or hooded supply or exhaust units, designed for continuous use. Belted or direct drive. Available in steel, galvanized, stainless, and aluminum construction. Sizes 12" to 72", capacities to 91,800 CFM. High Temperature Roof Ventilator Model SV40 Bulletin 653 Model SV40 High Temperature Roof Ventilator Patented reversible fan and modulating damper control systems make a unique year-round ventilation device capable of four functions: Supply Air, Building Exhaust, Recovery (Heat Saver), and Mixed Air modes. Heat Saver mode saves energy by moving warm air from the ceiling to the work area and maintaining a uniform temperature throughout the room. Sizes 24" to 60", capacities to 62,100 CFM. Vertical Weatherproof Exhaust Silencer Flyer VWES Vertical Weatherproof Exhaust Silencer Belt driven tubeaxial fan designed for use as a standard roof exhaust fan and for high temperature smoke and heat exhaust. Capable of 600 F continuous, 800 F extended, and a minimum of 8 hours at 1000 F operation. Complies with IRI recommendations. Sizes 24" to 60", capacities to 55,000 CFM. One-piece construction combines silencer and backdraft damper. The unique design allows rainwater to drain through slots to the exterior of the unit. Available in sizes 42" to 84". 8 Aerovent Bulletin G-99

9 Roof Ventilators Spun Aluminum Power & Gravity Ventilators Bulletin 102 Model ACX/ACXD Model AWX/ATDW Model ATB/ATD Model ATBR/ATDR Model AWXR/ATDWR Centrifugal Downblast Centrifugal Wall Centrifugal Upblast Centrifugal Upblast Centrifugal Wall Roof Exhauster Exhauster Roof Exhauster Restaurant Exhauster Restaurant Exhauster Centrifugal Downblast Roof Exhausters Models ACX/ACXD Designed for general exhaust applications involving relatively clean air at normal temperatures. Centrifugal wheel with non-overloading, backward inclined tapered blades for maximum efficiency and quieter operation. High efficiency spun type inlet. Power and rotating components mounted on neoprene isolators to reduce vibration and sound. Direct drive and belt driven models available. Sizes 8" to 48", capacities to 28,700 CFM, pressures to 3 1 4" SP. Centrifugal Wall Exhausters Models AWX/ATDW/AWXR/ATDWR For general exhaust applications involving relatively clean air at normal temperatures. Design eliminates vibration. Weatherproof construction, lightweight, durable. Designed for simplicity and with a pleasing, unobtrusive appearance. Restuarant models are specifically designed for exhausting grease-laden air from kitchens, restaurants, cooking and dishwasher hoods. Direct drive and belt driven units available. Sizes 12" to 31.5", capacities to 11,600 CFM, pressures to 3 1 4" SP. Centrifugal Upblast Roof Exhausters Model ATB/ATD/ATBR/ATDR Spun aluminum power roof ventilator designed for the removal of laboratory fume hood exhaust, kitchen air, smoke and chemical process exhaust high above and away from the roof of commercial and restaurant facilities. Specially designed tapered blades provide efficient, quiet operation and high performance. Restuarant models are specifically designed for exhausting grease-laden air from kitchens, restaurants, cooking and dishwasher hoods. UL (Electric) Listed power roof ventilator. UL (Grease) Listed power roof ventilators for restaurant exhaust appliances. Maximum operating temperature: 300 F. Sizes 12" to 48", capacities to 29,100 CFM, pressures to 3 1 4" SP. Filtered Units Filtered Air Supply Models FF, FSR, FSWD, FSWB Bulletin 664 Wall Mounted Filter Fan (FF). Direct drive axial flow fan for supplying low volume filtered air. Propeller is suitable for medium temperatures and mildly corrosive atmospheres. Unit consists of a fan section, filter cabinet, and motor guard. Sizes 12" to 30", capacities to 5,370 CFM. Model FSWD, FSWB Wall Mounted Filtered Air Supply Model FF Wall Mounted Filter Fan Model FSR Roof Mounted Filter Fan Wall Mounted Filtered Air Supply (FSWD, FSWB). Belted or direct drive axial flow fan. For installations requiring fresh, filtered air. Unit consists of fan, shutter, and filter assembly. Filters are mounted in a cabinet on the plenum chamber for wall installations. Sizes 24" to 60", capacities to 52,500 CFM, pressures to 1" SP. Roof Mounted Belted Filtered Air Supply (FSR). Axial flow roof ventilators for supplying fresh filtered air. Feature the Macheta tipped propeller. Available in sizes 24" to 60", capacities to 49,500 CFM. Aerovent Bulletin G-99 9

10 Fiberglass Fans Fiberglass Centrifugal SWSI Fan Model SWCBF Bulletin 743 Fiberglass Axial Flow Fans Models FBD, TFBD, VTFBD, FRV, FDP Bulletin 185 Model SWCBF Fiberglass Centrifugal SWSI Fan Constructed for durability and resistance to most chemicals. All airstream parts are constructed of fiberglass reinforced plastic mounted on an all welded, heavy-gauge steel base. Features Aerovent s FA9 wheel with backward inclined airfoil blades offering a power limiting characteristic, high operating efficiency, and low noise levels. Sizes 12" to 39", capacities to 22,250 CFM, pressures to 13" SP. Fiberglass Pressure Blower Model HPBF Bulletin 950 Model HPBF Series 14 Fiberglass Pressure Blower Model FBD Fiberglass Belt Driven Tubeaxial Model FDP Fiberglass Direct Drive Panel Fan Type FG Belt Driven Tubeaxial Model FBD The model FBD is the standard Aerovent fiberglass belt driven tubeaxial with many years of proven success in numerous applications. Features the Type FG six-bladed propeller. For medium performance range requirements. Sizes 14" to 60", capacities to 51,900 CFM, pressures to 1 1 2" SP. Direct Drive Panel Fan Model FDP The Model FDP panel fan is constructed from corrosion-resistant plastic and utilizes the Type FG propeller. Sizes 18" to 48", capacities to 41,800 CFM, pressures to 1" SP. Designed for small, constant air volumes at high static pressures. Airstream parts constructed of fiberglass reinforced plastic for corrosion resistance to most chemicals. Stainless steel shaft, construction from Dow Vinyl Ester and fire-retardant resin available as options. Sizes 18", 22", 28", capacities to 4712 CFM, pressures to 36" SP. Fiberglass Inline Centrifugal Model CBDF Bulletin 360 Model CBDF Fiberglass Inline Centrifugal Fan For exhausting gases, fumes, and vapors from chemical processes. Straight-through airflow combines the compact advantage of an axial fan with the performance characteristics of a centrifugal fan. Features Aerovent s FA backward inclined airfoil wheel for non-overloading performance, high operating efficiency and low noise. Sizes 12" to 39", capacities to 35,900 CFM, pressures to 7" SP. Model TFBD Fiberglass Belt Driven Tubeaxial Model FRV Fiberglass Roof Ventilator Type TF Belt Driven Tubeaxial/Vaneaxial Models TFBD, VTFBD A corrosion-resistant fan with more performance capability and a lower noise level than the Model FBD. Features the Type TF, 7-bladed propeller. Sizes 12" to 60", capacities to 83,200 CFM, pressures to 1 1 2" SP. Adding a vane section to the Model TFBD converts it to a model VTFBD vaneaxial fan for improved performance. All exposed surfaces are corrosion resistant. Sizes 12" to 60", capacities to 81,200 CFM, pressures to 4" SP. Roof Ventilator Model FRV The advantages of the Model FBD, TFBD, and VTFBD tubeaxial fans can be obtained in a roof ventilator assembly by adding a fiberglass stack cap, curb base, and motor cover. Sizes 14" to 60", capacities to 50,800 CFM, pressures to 1 1 2" SP. 10 Aerovent Bulletin G-99

11 Fiberglass Radial Blade Fan Model RBF Bulletin 750 Fiberglass Fans Features a radial blade wheel design constructed of solid FRP with a steel hub embedded and encapsulated into the backplate. The wheel is attached to a 316 SS stepped shaft using a 316 SS retaining plate. Fan housings are solid FRP hand lay-up construction utilizing corrosion grade flame retardant vinyl ester resin. A glass veil is standard for airstream surfaces providing a resin rich liner to maximize chemical resistance. Wheel diameters from 10" to 57", capacities to 38,300 CFM, pressures to 18" SP. Air Make-up Model RBF Fiberglass RadiaI Blade Fan Gas-Fired Air Make-Up Units Models GA, GAS, GACDW, GACSW Bulletin 864 Steam Air Make-Up Units Models S, SACSW, SACDW Bulletin 856 Complete air supply systems for the ultimate in safety and dependability. Packaged units available in propeller and centrifugal types. Available with forward curved, backward inclined, or airfoil blade. Capacities to 100,000 CFM, 10,000,000 Btu/hr, external pressures to 5" SP. Direct Digital Control: Available with Aerovent s Direct Digital Control System which allows you to remotely monitor and control your HVAC system from your PC. Door Air Heater Gas Door Air Heaters Models NDH, PDH Bulletin 896 Steam Distributing Tube Coil gives good temperature distribution, maximum freeze protection, and allows expansion of the tubes without transmitting stresses to the tubes. Propeller and centrifugal models available. Centrifugal unit available with backward curved or forward inclined airfoil blades. Units come assembled and include fan, coil, vacuum breaker and motorized shutter. Available options include remote operating station, outlet temperature control, directional discharge grille, air distributor, inlet hood, inlet hood less vanes, and inlet/discharge elbows. Capacities to 60,000 CFM and 343,000 to 5,000,000 Btu. Air Coolers Spray Type Air Cooler Model AC Bulletin 1103 Automatic direct-fired gas units provide instant, full heat when door opens; heat and fan shut off together when door closes. Compact, packaged construction, fully assembled. Designs for natural gas and propane; models available for horizontal, angular or vertical mounting. Outlet velocities to 3500 FPM, capacities to 6200 CFM, 990,000 Btu/hr with gas unit. High velocity, packaged unit is an efficient, simple and economical approach to spot or general cooling in highheat producing areas. Polypropylene nozzles, mounted in two opposite-spray banks, provide maximum saturation and heat transfer efficiency. High velocity eliminator. Available separately or with Aerovent air make-up. Capacities to 110,000 CFM, 3,848,000 Btu, outlet velocities to 1,520 FPM. Aerovent Bulletin G-99 11

12 1MPP Trenton Lane North Minneapolis, MN Ph o n e: Fax: w w w.aerovent.c o m

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

Air Make-Up Units. Product Line Overview & Capabilities

Air Make-Up Units. Product Line Overview & Capabilities Air Make-Up Units Product Line Overview & Capabilities Air Make-Up Units Customized Solutions Unmatched Flexibility As one of the most sophisticated manufacturers of Air Make-Up Units, Aerovent s unique

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX010 November 2005 AXIAL POWER ROOF VENTILATORS Power Roof Ventilators Twin City Fan & Blower offers a wide variety of Power Roof Ventilators (PRVs). The PRVs have been

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

THREE-WAY HEAT SAVER/VENTILATOR

THREE-WAY HEAT SAVER/VENTILATOR BULLETIN 673 December 2009 THREE-WAY HEAT SAVER/VENTILATOR Modulated Damper Control System Operates in Supply, Exhaust, Heat Saver and Mixed-Air Modes Models RREH & RRES Three-Way Heat Saver/Ventilator

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

Industrial Fans & Blowers

Industrial Fans & Blowers Industrial Fans & Blowers IN-LINE FANS ADD DIRECT DRIVE TUBEAXIAL FANS FEATURES & BENEFITS Spark resistant, cast aluminum airfoil axial impeller Aerodynamically efficient performance Factory set adjustable

More information

Glossary of Terms Laboratory & Fume Exhaust Fans

Glossary of Terms Laboratory & Fume Exhaust Fans Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully

More information

Centrifugal Fans, Non-Overloading, Backward Inclined

Centrifugal Fans, Non-Overloading, Backward Inclined BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Energy Guide. Fan Efficiency Grades. FEG Ratings. July Energy Guide Fan Efficiency Grades s July 2013 Certified Fans Location Mounting Airflow Application Drive Type Impeller Type Performance Model Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted

More information

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY PRODUCT GUIDE THE NEW YORK BLOWER COMPANY (800) 208-7918 nyb.com In 1889, two brothers J.W. Mathis and August Mathis opened a sheet-metal shop on the South Side of Chicago and formed Mathis Brothers Company.

More information

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING TM MITTAL ENGINEERING M i t t a l E n g i n e e r i n g i s o n e o f t h e l e a d i n g m a n u f a c t u r e r s q u a l i t y e n g i n e e r i n g

More information

Direct Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air Direct Gas-Fired Make-Up Air Model TSU Heavy Duty, High Airflow Applications Manufacturing and Industrial Facilities Up to 64,000 cfm August 2012 Products Model TSU Direct Gas-Fired Make-Up Air Unit The

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

an ISO 9001 Company Bulletin PR-112

an ISO 9001 Company Bulletin PR-112 an ISO 9001 Company Bulletin PR-112 Airfoil Fans SINGLE WIDTH DOUBLE WIDTH SQUARE SQA FANS DIRECT DRIVE FANS Known for high efficiency, low sound levels, and low horsepower, the Design 51 fan is used extensively

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

Plenum Fans. Model HPA. Direct Drive

Plenum Fans. Model HPA. Direct Drive Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in

More information

Indirect Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air Indirect Gas-Fired Make-Up Air Model IG 800 to 7,000 cfm Up to 400,000 Btu/hr Multiple Furnace Control Options Optional Evaporative Cooling May 20041 Product Features Model IG Indirect Gas-Fired Make-Up

More information

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success. BLOWERS With over 70 years of experience and expertise our fans will ensure your projects are a success. ABOUT OUR PARTNERSHIP has been representing Chicago Blower Corporation (USA) since 2004, offering

More information

Bulletin FH05 FUME EXHAUST

Bulletin FH05 FUME EXHAUST Bulletin FH05 FUME EXHAUST Models: FH, FHL Curb Mounted Centrifugal Fans Fume Exhaust Systems - FH/FHL Introduction The PennBarry FH fans are designed to meet the various requirements for fume exhaust

More information

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,

More information

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES ENVIRO UNIT ENGINEERING MANUAL KES SERIES The Cadexair INC. Enviro System (KES) and Recirculation System (KRS) have been designed and constructed specifically for a commercial kitchen exhaust. The units

More information

QUICKSHIP PROGRAM. Twin City Fan QuickShip

QUICKSHIP PROGRAM. Twin City Fan QuickShip QUICKSHIP PROGRAM QUICKSHIP PROGRAM Twin City Fan & lower stocks a large number of products for quick shipment, so your tight project deadlines can be met and downtime on replacement work can be held to

More information

CML Northem Blower Inc. Air Movement Equipment

CML Northem Blower Inc. Air Movement Equipment CML Northem Blower Inc. Air Movement Equipment For years Northern Blower has been designing and manufacturing fan equipment for commercial and industrial applications. Product integrity and outstanding

More information

SECTION AXIAL FANS

SECTION AXIAL FANS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT Fans, Heaters & Controls 1 GRAIN CONDITIONING EQUIPMENT SIOUX STEEL COMPANY Innovative Solutions Manufactured By A Family-Owned Company With A ENGINEERING

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

Understanding Fan System Effects

Understanding Fan System Effects Fan Application FA/101-99 A technical bulletin for engineers, contractors and students in the air movement and control industry. Understanding Fan System Effects The air moving industry uses a common term

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source! Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also

More information

GreenJet Transfer Fans

GreenJet Transfer Fans GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into

More information

JM Aerofoil Fans Bulletin JMA60-05

JM Aerofoil Fans Bulletin JMA60-05 www.howden.com JM Aerofoil Fans Bulletin JMA60-05 Introduction The high performance JM Aerofoil Fan Benefits of the JM Aerofoil Fan include compactness, low cost, high efficiency and rugged design. Availability

More information

QUICKSHIP PROGRAM. Twin City Fan QuickShip

QUICKSHIP PROGRAM. Twin City Fan QuickShip QUICKSHIP PROGRAM QUICKSHIP PROGRAM Twin City Fan & lower stocks a large number of products for quick shipment, so your tight project deadlines can be met and downtime on replacement work can be held to

More information

Fan Arrangements, Rotation, Discharge and Motor Position

Fan Arrangements, Rotation, Discharge and Motor Position FAN ENGINEERING Information and Recommendations for the Engineer Fan Arrangements, Rotation, Discharge and otor Position FE-3900 Introduction Fan arrangements and classes are industry standards that have

More information

YORK COMMERCIAL AND INDUSTRIAL SUPPLY AND EXHAUST FANS. YORK Commercial and Industrial Supply and Exhaust Fans. Creating air-flow efficiencies

YORK COMMERCIAL AND INDUSTRIAL SUPPLY AND EXHAUST FANS. YORK Commercial and Industrial Supply and Exhaust Fans. Creating air-flow efficiencies YORK Commercial and Industrial Supply and Exhaust Fans Creating air-flow efficiencies 1 DOWNBLAST EVD Roof-mount, spun aluminum downblast. Direct or belt drive, Gplus EC motor option. Application: General

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

MXI Mixed Flow Inline Fan

MXI Mixed Flow Inline Fan MXI Mixed Flow Inline Fan PRODUCT GUIDE PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3 CERTIFICATIONS & LISTINGS 4 MIXED

More information

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications Bulletin C6200 MAY 20 3 Buffalo Air Handling Big Buffalo Custom Applications Buffalo Air Handling Big Buffalo The historic strength of Buffalo Air Handling is the custom designed air handling equipment

More information

Modular Heating & Ventilating Unit Model IGX-HV

Modular Heating & Ventilating Unit Model IGX-HV Modular Heating & Ventilating Unit Model IGX-HV Indirect Gas-Fired Heating Evaporative Chilled Water DX Cooling October 2008 Product Features Model IGX-HV Indirect Gas-Fired Heating and Ventilating Unit

More information

The Advantages of Choosing Centrifugal Fans

The Advantages of Choosing Centrifugal Fans The Advantages of Choosing Centrifugal Fans Introduction Centrifugal fans are widely used for various commercial and industrial applications today. These fans are popular choices for automotive, heating,

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name University of Houston Master Construction Specifications Insert Project Name SECTION 23 82 20 - FANS, AIR INTAKES AND RELIEF VENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

Product Handbook. Moving Your Way. Our Complete Product Offering. PennBarry Manufacturer of Ventilation Products

Product Handbook. Moving Your Way. Our Complete Product Offering. PennBarry Manufacturer of Ventilation Products Our Complete Product Offering Moving Your Way PennBarry Manufacturer of Ventilation Products www.pennbarry.com Additional PennBarry Product Information: General & Industrial Product Catalogs For detailed

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 08:50:16 AM Job Name: EarthWise Modular Climate Changer Full Spec Location: Any Town, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SUBMITTALS Submittals

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15815 Metal Ducts This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

Ducted Propeller. Airflow Volume

Ducted Propeller. Airflow Volume Total Pressure Radial-Blade Centrifugal Tubeaxial Backward-inclined Airfoil Centrifugal Forward-curved Centrifugal Ducted Propeller Airflow Volume Figure 2: Forward-Curved Centrifugal Fan

More information

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260) Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN 46706 (260) 925-6550 Fax: (260) 925-6093 Industrial Facility Midwest Re: Facility Ventilation Audit Schust Engineering, Inc. is pleased

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10 Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance

More information

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan FAN TYPES In order to cover a wide range of applications, fans are manufactured in a variety of type. They can be classified under three general types : (a) Centrifugal, (b) Axial and (c) Mixed flow. Table

More information

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07 www.howden.com Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07 Evase Vaneaxial fans by Howden can save energy over the installed life of the system by recovering the kinetic energy contained

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional

More information

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features: RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

H2O COIL. Heat Exchange and Air Movement Products Product Preview

H2O COIL. Heat Exchange and Air Movement Products Product Preview 2011 Product Preview ATQ Series Hot Water Duct Coils Meets ARI 410 Standards 1, 2 and 3 Row Hot Water Duct Coils Galvanized Steel 18 ga. frame w/1 flange Aluminum Fins,.0045 thickness. Copper Tubing, 1/2

More information

AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE

AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE AERATION AND GRAIN CONDITIONING FANS AND HEATERS PROVEN & DEPENDABLE WWW.GRAINSYSTEMS.COM PROVEN & DEPENDABLE The demands of farming are never-ending. Maintaining consistent grain quality is essential

More information

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section. SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification

More information

Axial flow fan AXICO ANTI-STALL

Axial flow fan AXICO ANTI-STALL Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise:

More information

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector ALUMINUM REPAIR CERTIFICATION EQUIPMENT Eliminate hazardous aluminum dust with a Eurovac system BODY REPAIR EQUIPMENT OPTIONS Product Description When repairing an aluminum structured vehicle, it is essential

More information

Utility and Centrifugal

Utility and Centrifugal Utility and entrifugal Utility and entrifugal reenheck s tiered centrifugal product offering reenheck s tiered model approach gives you flexibility in size, performance and construction, matching the appropriate

More information

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc. System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect

More information

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio Tempered Air Heating Equipment Series GFR GMC GMP SAH SCH SFC SMC SMP 77 78H 78V 79 811 Hartzell Fan, Inc., Piqua, Ohio 45356 January 2011 Index Hartzell Model Code Explanation..................... Page

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

PRODUCT HANDBOOK A Complete Product Overview

PRODUCT HANDBOOK A Complete Product Overview PRODUCT HANDBOOK A Complete Product Overview PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION 3 MORE INFORMATION 3 COMMERCIAL

More information

A. This Section includes air-handling units with coils for indoor installations.

A. This Section includes air-handling units with coils for indoor installations. SECTION 237313 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes air-handling units with coils for indoor installations. 1.2 SUBMITTALS A. Product Data: For each type of indoor air-handling unit

More information

Vision and Skyline Semi-custom Air Handlers

Vision and Skyline Semi-custom Air Handlers Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions

More information

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors. SECTION 233516 - ENGINE EXHAUST SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Exhaust fans. B. Ductwork and duct fittings. C. Inlet fittings. D. Accessories. E. Carbon monoxide detectors. 1.2 RELATED

More information

ENGINEERING LETTER 4

ENGINEERING LETTER 4 ENGINEERING LETTER 4 The New York Blower Company 7660 Quincy Street, Willowbrook, Illinois 60521-5530 TEMPERATURE AND ALTITUDE AFFECT FAN SELECTION INTRODUCTION Fan performance changes with the density

More information

MECHANICAL VENTILATION

MECHANICAL VENTILATION MECHANICAL VENTILATION Natural and Mechanical Systems Four (4) possible combinations of natural and mechanical ventilations tions are as follows; Natural inlet and outlet; utilizing open able windows,

More information

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans PARAG FANS & COOLING SYSTEMS LTD. Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans Registered Office & Works Plot No.1/2B & 1B/3A, Industrial Area No.1 A.B.Road, Dewas 455001 (M.P.)

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features: RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons

More information

OUR EXPERTISE, YOUR AIR-MOVING SOLUTION CONCEPT. PROTOTYPE. IMPLEMENTATION. SUPPORT. ABSOLUTE RELIABILITY. VISIT US: LauFan.com

OUR EXPERTISE, YOUR AIR-MOVING SOLUTION CONCEPT. PROTOTYPE. IMPLEMENTATION. SUPPORT. ABSOLUTE RELIABILITY. VISIT US: LauFan.com OUR EXPERTISE, YOUR AIR-MOVING SOLUTION CONCEPT. PROTOTYPE. IMPLEMENTATION. SUPPORT. VISIT US: ABSOLUTE RELIABILITY. INNOVATING FOR OVER 80 YEARS No application is too big or too small. For decades, Lau

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

Gas-Fired Unit Heaters Commercial & Industrial

Gas-Fired Unit Heaters Commercial & Industrial 6-107.10 February, 2005 Gas-Fired Unit Heaters Commercial & Industrial GRAVITY VENTED PD, BD POWER VENTED PDP, BDP, HD SEPARATED COMBUSTION PSH, BSH, HDS GAS-FIRED, GRAVITY-VENTED UNIT HEATERS Low Initial

More information

Make-Up Air March 2012

Make-Up Air March 2012 Make-Up Air March 2012 Comfortable energy efficient kitchen ventilation starts here. At Larkin Industries, our goal is to manufacture well-designed kitchen ventilation systems with environmentally sustainable

More information

XeteX, Inc. All Rights Reserved.

XeteX, Inc. All Rights Reserved. Model DXH Custom, packaged, roof mounted or indoor mounted unit with cooling (DX or Chilled Water) and an air-to-air aluminum flat plate exchanger designed to provide pre-cooling and reheat. The DXH is

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty MODEL OVERVIEW The POWERVENT (PV) series of direct drive centrifugal in-line duct ventilation fans consists of twelve model sizes 4, 5, 6, 8, 10 and 12.4 respectively. All models are designed for direct

More information

CUSTOM PRODUCTS AND SERVICES GUIDE

CUSTOM PRODUCTS AND SERVICES GUIDE NEW YORK BLOWER COMPANY (800) 208.7918 nyb.com CUSTOM PRODUCTS AND SERVICES GUIDE Why New York Blower Company The New York Blower Company is a full service fan manufacturer offering a complete array of

More information

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division AMERICAN COOLAIR CORPORATION Greenhouse Ventilation Systems Farm Products Division AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion

More information

Fuji Electronic VFC 084P-5T

Fuji Electronic VFC 084P-5T Fuji Electronic VFC 084P-5T Fuji s complete line of ring compressors is designed to meet the most critical application requirements. Each features an impeller, mounting base and housing manufactured of

More information