Comfort Compact Controller ZG 252N

Size: px
Start display at page:

Download "Comfort Compact Controller ZG 252N"

Transcription

1 Comfort Compact Controller ZG 252N OPERATION AND PUTTING INTO SERVICE C ,5 3,5 3,0 2,5 2 1,8 1,6 1,4 A 1,2 1 0,8 0,6 0,4 0 ZG 252 N auto1 B C ,6-20 C P1 C B A P1 C B A 20 CB L1 L2 S P1 C B A

2 // //// System diagram AF TW ZG 252N // VF //// P //// VM ZR CBZG037.cdr ZG Control Unit ZR Heating mixing valve VF Flow sensor VM Servomotor AF Outdoor sensor TW Temperature selector (Option) P Heating circuit pump

3 Operating of the Control (see figure on the left) The outdoor sensor (AF) measures the outside temperature. It transmits its measured value to the control unit, which determines the necessary hot water temperature (flow temperature). Theflow sensor (VF) measures the water temperature in the heating flow. It senses also the changes that are caused by the oscillations in the boiler or heating return temperature. If the flow temperature differs from the target value, the control unit adjusts the mixing valve (ZR) with the servomotor (VM) so that the right heat input can be reached. Themixing valve determines the flow temperature by mixing the boiler s hot water with the colder return water. Theheating circuit pump (P) provides for the heating circuit of the hot water. It is switched off by the control unit, if the heating circuit is necessary. Thetemperature selector(tw) is used as a remote control, e.g. if the control unit is mounted in the cellar. The room temperature can be changed with selector knob P2. The party switch S1 makes it possible to increase the night-time decrease in temperature. (The temperature selector is not needed necessarily and is not supplied with the compact control unit.)

4 Operating and Display Components Pos. Function Basic Setting A B Heating curve diagram Parallel shift C Reduced mode -8 P1 Sensitivity 10 S Operating mode selector auto 1 L1 Hotter LED (red) L2 Colder LED (green) 1 Instructions compartment 2 Heating curve diagram 3 Basic settings 4 Reserve Trip Pins 5 Inserted trip pins 6 Timer (optional) 7 Pointer for the current time Settings on the temperature selector P2 Selector knob 0 S1 Party switch auto

5 Operating mode selector manu The control unit is deactivated (the timer runs). The mixing valve can be set manually (by hand). The heting circuit pump is switched on. auto 1 Recommended setting for improved energy saving: Automatic change between day and reduced mode according to the timer, with night switch-off. During night mode, the mixing valve remains closed completely at outside temperatures of more than +2 C and the heating circuit pump is switched off. At outside temperatures below +2 C the pump runs for frost protection and the controller works with the night decrease set on the setting knob C. auto 2 Recommended setting for automatic change between day and reduced mode according to the timer. The decrease set on the setting knob C is active. 2 The mixing valve is kept closed constantly and the heating circuit pump is switched off. The timer runs. Energy saving tip: A particularly great energy savings can be made if the switch position auto 1 is selected. In this switch position it may happen that the heating lasts longer.

6 LED s L1 L2 Both LED s light up: neutral Mixing valve stops Only the red LED lights up: hotter Mixing valve opens Only the green LED lights up: colder Mixing valve closes In the manu or 2 settings of the operating mode selector S there is no LED display.

7 Putting into service Set the timer 6 at the current time. Set the operating mode selector S on auto 1 or auto 2. The switch is in position 2 when it leaves the factory. The pump is hence switched off and is protected against the dry-running of the empty heating system. Warning: In switch position 2 the 230V line voltage is between terminals 8 and 11 of the control unit! (The servo motor closes). The remaining factory settings are printed under 3 on the controller. Timer for reduced mode 6 With the aid of the timer, the temperature of the rooms can be automatically reduced when they are not used to save on the operating costs. The timer has a built-in power reserve of approx. 60 hours thanks to a rechargeable battery.

8 Changing the program Factory settings: red pin 6:00, blue pin 22:00. Pull out the trip pin and insert it again at the desired switchon time. Push in the trip pins until they reach the stop. Owing to the different lengths, the trip pins must always be inserted in a red/blue alternate order. The red trip pin switches on day mode, while the blue pin activates reduced mode. In order to make sure that the rooms are heated well in the morning, the heating system s day mode should be activated between a half an hour and an hour before using the rooms. Energy saving tip: Reduced mode can be activated up to an hour before the room is left. The storage capacity of the heating system and building is enough to keep the rooms warm for some time. Timer with day program The day program is repeated every 24 hours. If a (second) decrease in temperature is desired in the course of the day to save energy, the program needs to be extended. Take the extra trip pins 4 and insert them at the desired time. CB cdr

9 Example: Desired time program Normal temperature: 6:00 h to 8:00 h and 16:00 h to 22:00 h Night decrease: 22:00 h to 6:00 h day decrease: 8:00 h to 16:00 h Position of the trip pins red pin 6:00 h Start day mode (normal temperature) blue pin 8:00 h Start daily decrease red pin 16:00 h Start day mode (normal temperature) blue pin 22:00 h Start night decrease Timer with week program The timer has a changeable dial. With the week program, dialling a different heating program for each weekday is possible. The dial is prepared ex factory for the day program and, if required, it can be changed to week program (see installation instructions). Setting the right time To set the time, the time dial is to be placed on the trip pins andtur - ned clockwise until the indication on the setting marker 7 matches with the current time.

10 Optimization of the Settings Basic settings for a hot water heating system working at water temperatures between 20 C and 90 C: A 1,6 B 0 C -8 I Day mode curve / II Reduced mode curve During the optimization, the radiator valves are completely open. (Set the radiator thermostat valves at the maximum value) Close all windows and doors. Proceed gradually by making only small changes! Wait for the outcome of the change after each setting (approx. 1 h). Depending on the type of system radiator/convector heating (up to 90 C), low temperature heating, air heating, and depending on the layout of the heating surfaces, various flow or supply temperatures are needed to reach the right room temperature and hence also different settings on the setting knobs. Heating curve selection (Setting knob A ) The adaptation of the controller to the heating system and to the building characteristics of the house is carried out by setting the heating curve with the setting knob A. The heating curves show the relation between the outside temperature and the necessary flow temperature. Each building must be assigned an optimal heating curve.

11 The lower the maximum flow temperature at basis of the calculation of the heating system and the more numerous the heating surfaces are, the more level the heating curve can be selected and hence the smaller the numeric value to be set on the setting knob A is. Basic setting: A 1.6 (curve I in the diagram). Displacement (room temperature change) With setting knob B, the heating curve set on the setting knob A can be moved in parallel along the room temperature axis (represented obliquely in the diagram). This displacement leads to a change in the room temperature. Basic setting: B 0 The scale division on setting knob B corresponds approximately to the change in the room temperature in K ( C). + means increase the room temperature means lower the room temperature B 0 corresponds approx. to a room temperature of 20 C B +2 corresponds approx. to a room temperature of 22 C Pay attention also to Remote Control TF 22.

12 Night decrease setting knob C On setting knob C, the size of the night decrease to be triggered by the timer is to be set. The setting on setting knob C leads to a parallel shift of the heating curve downward along the room temperature axis (dotted curve II ). The flow temperature and the room temperature are hence reduced. The scale division on setting knob C corresponds approximately to a K ( C) room temperature decrease. 0 means no decrease. Example: C -8 means that the room temperature at night can drop by approx. 8 K below the set day temperature and hence e.g. to 12 C (20 C 8 C = 12 C). The recommended setting C -8makes it possible to save quite a lot of energy with a large nighttime decrease. In some buildings the rooms may become too cold. In these cases it is recommended to set a night decrease value of only about 5 C ( C -5) or to switch on day mode earlier.

13 Remote control TF 22 (optional) Setting the Room Temperature On setting knob P2, the setting of the room temperature can be fine-tuned. The normal setting is the room temperature set on the control unit (setting knob B ) (mainly 20 C to 22 C, the room temperature is not measured on the temperature selector). The scale on the selector is divided from-7 to +7 and matches more or less to the change in degrees. + Increasing the Room Temperature Lowering the Room Temperature The functioning of the selector knob P2 corresponds to the functioning of the setting knob B on the control unit and gives a parallel displacement of the heating curve along the oblique room temperature axis indicated in the diagram. S1 P2

14 The values on the selector knob P2 and the setting knob B are added on the control unit: Examples B 0 B +1 Selector knob P Room temperature [ C] If no temperature selector is available, the desired room temperature can be set only on the setting knob B of the control unit.

15 Party switch S1 The temperature selector s party switch has the following settings: auto automatic change to day mode or to reduced mode according to the timer manual day mode, timer not active manual night mode, timer not active (the night duration mode is possible only if the hours are set.) If, for example, the heating is to stay open longer, the Partyswitch is to be set on manual day mode. Do not forget to switch back if the automatic mode is to be activated again later on.

16 Remote control TFU 22 (optional) When using remote control TFU 22 (instead of TF 22), a time can be pre-set (e. g. 10 days) during which the heating system is to work in economy mode (the anti-freeze protection is hence active.) At the expiry of the selected time, the TFU 22 resets the control unit back to automatic mode. There is no need to remember to reset the switch. Economy mode (night) is possible only if the time is set. P2

17 Adjustments to the Room Temperature If in case of varying outside temperatures the setting of the TF needs to be changed frequently to obtain a steady room temperature, modify the control unit s setting as follows: 1. The room temperature is too low: In the rooms it is... a) too cold at any outside temperature: A 1.6 B b) too cold only with mild outside temperatures: A B c) too cold only at very cold temperatures: A B 0 2. The room temperature is too high: In the rooms there is... a) too hot at any outside temperature: A 1,6 B 1 2 b) too hot only with mild outside temperatures: A 1.8 B 1 2 c) too hot only at very cold temperatures: A B 0 Tendency of correction A no corr. B increase A decrease B increase A increase B no corr. A no corr. B decrease A increase B decrease A decrease B no corr.

18 Pump Demand-responsive mode The control unit can switch on the heating circuit pump on a demand- responsive basis. It is switched on only by the control unit if a heat input is needed, i. e. if the target value of the heating flow temperature is higher that the target value of the room temperatur (pump logic). In case of the frequently usual setting of the control unit S auto 2 / B 0 / C -8 the heating circuit pump is switched off: in day mode at outside temperatures over 20 C in reduced mode at outside temperatures below 12 C In position auto 1 of the operating mode selector, the switch-off times of the pump are longer. Blocking protection The timer is equipped at the factory so that the heating circuit pump runs for about a minute every day, even if no heating is necessary (Requirement: the operating mode selector S is on auto 1 or auto 2 ). The heating circuit pump can hence avoid remaining stuck and blocked also during long periods of idleness (summer).

19 Troubleshooting Checklist Are the heater valves (thermostat valves) turned too far? Is the boiler at the required temperature? Read the boiler thermometer. Is the burner ready? Is the burner failure lamp on? If necessary, press the reset button. Was the temperature selector set by mistake? Check the setting of the selector knob P2 or of the Party switch S1. Check the setting on the control unit Setting knobs A B C and operating mode selector S Is the timer running? Is the displayed time correct? Check the time and switch-on point. If the problem still has not been solved after checking the settings, position the setting knob B on +7 The servomotor should now open the mixing valve and the red LED L2 should light up. If this is not the case, the control system has failed. Contact your heating technician.

20 Manual mode CB cdr

21 Manual mode (left-hand fig.) In case of the breakdown of the heating mode regulation you can proceed temporarily as follows: 1. Set the operating mode selector S on manu. 2. Open the mixing valve by hand until the desired flow and room temperatures are reached. The coupling incorporated in the mixing valve drive unit provides for the release of the connection between the motor and the mixing valve. Press firmly on the unlock key on the cover of the drive unit and keep the key pressed (firmly!). Use the setting lever to set the mixing valve to the desired position. After eliminating the problem, the mixing valve is set again to the right position by the control unit in automatic mode.

22 Heating curves Flow temperature[ C] C A I II CB50427E Room temperature change[ C] 0 B C External temperature[ C] -20 C

23 Instructions for the technician (only!) Removing the Timer (see also the installation instructions) 1. Pull out the instructions case. 2. Hold the timer by the two white stems and turn to the left until the connector is released. 3. Remove the timer. (To install the timer, proceed in the opposite order.) Pump activation If the temporary forced drive of the heating circuit pump is not desired while the heating system is idle, one of the jumpers on the back of the timer is to be removed. 1. Remove the timer. 2. Remove jumper Mount the timer again. Regulation Stability (Sensitivity) The stability of the regulation can be modified with the setting potentiometer P1. For the regulation technician: By means of P1, set the proportional range of the PD control unit. Recommended basic setting: P1 10. In case of unstable regulation, set higher values.

24 Reference Installation instructions Compact Control Units ZG 215N / 215 VN / 252 N GE 1H-0181 GE51 Operating Instructions ZG 252N: EN-2H0215 GE51 ZG 215N: EN-2H0216 GE51 ZG 215VN: EN-2H0217 GE51 Informationsschrift (Planning broschure in German) L3 Komfort-Compact Regler GE-0H 0327 GE51 Centra Regelungstechnik Honeywell AG Böblinger Straße 17 D Schönaich Telefon +49 (70 31) Telefax +49 (70 31) Technical data may be changed without prior notice. EN 2H-0215 GE51 R

Comfort Compact Controller ZG 215VN

Comfort Compact Controller ZG 215VN Comfort Compact Controller ZG 215VN OPERATION AND PUTTING INTO SERVICE 1 2 3 4 5 6 7 B C ( ) /// B C ZG215VN auto1-8 0 P1 C B 8311.7151 P1 C B CB50268 L1 L2 S P1 C B A Constant discharge temperature control

More information

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS Heating Controller SDC District Heating Controller DHC 43 OPERATING INSTRUCTIONS Copyright 2002 Honeywell Inc. EN2H-0220 GE51 R0802 SDC / DHC 43 Operating Instructions EN2H-0220 GE51 R0802 Contents SDC

More information

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502* User's Guide VI.7C.C5.02 2005.09 C66 *vi7cc502* *087R8069* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8069* *vi7cc502* Mixing controller with PI controlled

More information

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102*

C62. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C62. User's Guide. Installer's Guide *VIKME102* *087R8091* *087R8091* *VIKME102* User's Guide VI.KM.E1.02 2005.09 C62 *VIKME102* *087R8091* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8091* *VIKME102* Double mixing controller C62 VI.KM.E1.02

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602* User's Guide VI.7C.E6.02 2005.09 C37 *VI7CE602* *087R8070* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8070* *VI7CE602* Mixing controller with ON / OFF controlled

More information

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp COMPUTHERM For Evaluation Q7 Only. Programmable digital room thermostat Operating Instructions NEW software! GENERAL DESCRIPTION OF THE THERMOSTAT

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

ECL Comfort 110, application 116

ECL Comfort 110, application 116 Operating Guide ECL Comfort 110, application 116 (valid as of software version 1.08) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A Heating/Cooling Thermostat and Subbase Package T8196A/Q682A OWNER'S MANUAL M3375 Congratulations on your purchase of a Honeywell energy saving thermostat. The Honeywell name is your assurance of accurate

More information

Energy Ambassadors Guide

Energy Ambassadors Guide Energy Ambassadors Guide Energy Ambassadors Home Visit Guide Instructions for use This home visit guide has been developed to help non-energy professionals to identify energy related issues in their clients

More information

Home and Building Control Home and Building Control Helping You Control Your World

Home and Building Control Home and Building Control Helping You Control Your World M3375 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited/Honeywell Limitée 1985 Douglas Drive No. 740 Ellesmere Road Golden Valley, MN 55422

More information

TCW 2000 Ice liner refrigerator and freezer PIJ

TCW 2000 Ice liner refrigerator and freezer PIJ TCW 2000 Ice liner refrigerator and freezer OVER VIEW The unique rotomoulded Chest Freezer and inclined Refrigerator with two separate compartments and compressors worldwide Hold over time @ 32 C Hold

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

Operating Instructions

Operating Instructions Operating Instructions Heating Controller Landis & Staefa RVL469 Overview... 2, 3 Symbols used... 4 Info button... 5 Operating modes... 6 Switching the heating on... 7 Room temperature is not correct...

More information

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw Technical Guide Installation, Operation and Care EP E series 7 step electric boilers 26 and 42 kw Arkelstorpsvägen 88, 291 94 KRISTIANSTAD Tel +46 44-22 63 20, Telefax +46 44-22 63 58 e-mail: info@varmebaronen.se

More information

Operating Instructions

Operating Instructions Operating Instructions Control panel Logamatic 4323 For the user Please read carefully before use 6 720 618 563-11/2008 US/CA Contents 1 Introduction................................................ 4 2

More information

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control For the owner and the heating engineer Operating and Installation Manual VRC 400 Programmable weather compensator with separat HW time control GB Contents Contents Notes on the documentation..... 4 Symbols

More information

REA22 Room Temperature Controller

REA22 Room Temperature Controller REA22 Room Temperature Controller Basic Documentation Issue: 2.0 Controller series: A CE1P2276E 31.03.1999 Siemens Building Technologies Landis & Staefa Division Siemens Building Technologies Ltd. Landis

More information

ECL Comfort 110, application 130

ECL Comfort 110, application 130 Operating Guide ECL Comfort 110, application 130 (valid as of software version 1.08) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE Operating instructions For the operator Operating instructions VRT 350 Room temperature-controlled controller GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Operating

More information

Operating Instructions

Operating Instructions Operating Instructions Heating Controller SIGMAGYR RVL47 Overview... 2, 3 Symbols used... 4 Info button... 5 Operating modes... 6 Switching the heating on... 7 Room temperature is not correct... 8 Departing

More information

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps User guide TYBOX PAC Programmable thermostat for heat pumps TYBOX DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device compliant with the requirements of directives: 2004/108/CE

More information

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock RGR150 manual-final-091908:layout 1 9/19/08 8:59 AM Page 1 RGR150 USER S MANUAL Wireless Rain Gauge with Thermometer and Clock INTRODUCTION Thank you for selecting this Wireless Rain Gauge. This device

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler WARNING: Improper installation, setup, modification, operation or maintenance of the heating system can cause personal injury and property damage. Follow each appliances' instructions precisely. For assistance

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502* User's Guide VI.7B.D5.02 2005.10 P20 *VI7BD502* *087R8014* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8014* *VI7BD502* Boiler controller P20 VI.7B.D5.02

More information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions GB PLEASE LEAVE THIS INSTRUCTION WH THE USER ECOMFORT PLUS 25 HE User instructions All descriptions and illustrations provided in this manual have been carefully prepared but we reserve the right to make

More information

Weather compensated flow temperature control of heating and boiler systems

Weather compensated flow temperature control of heating and boiler systems Instructions ECL Comfort 110 Application 130 Weather compensated flow temperature control of heating and boiler systems User guide, Installation & Maintenance DH-SMT/DK VI.KT.G3.02 Danfoss 06/2008 How

More information

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER! WARNING Revise boiler control parameters only if you fully understand the purpose and result of the changes and on the advice of ECR Technical

More information

ROOM THERMOSTAT. with OpenTherm+ communication

ROOM THERMOSTAT. with OpenTherm+ communication ROOM THERMOSTAT with OpenTherm+ communication PT52 LARGE BACKLIT DISPLAY with intuitive navigation in English 9 WEEKLY PROGRAMS FOR CENTRAL HEATING (C.H.) 6 temperature changes per day 1 WEEKLY PROGRAM

More information

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V User Guide HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+ VB0124 VB0125 VB0127 PLEASE READ AND SAVE THESE INSTRUCTIONS. These products earned the ENERGY STAR by meeting strict energy

More information

Installation and servicing instructions

Installation and servicing instructions Installation and servicing instructions Programming unit RC35 For qualified professionals Please read carefully prior to commissioning and servicing 7 747 006 341-12/2006 GB Contents Contents Contents

More information

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons. Installation Guide: for the Warmup Tempo Digital Programmable Thermostat The world s best-selling floor heating brand Introduction The Tempo thermostat is designed to aid in the comfort of your home by

More information

COMPUTHERM Q3 digital room thermostat

COMPUTHERM Q3 digital room thermostat COMPUTHERM Q3 digital room thermostat Operating Instructions NEW design! GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q3 type switched-mode room thermostat is suitable to regulate the overwhelming

More information

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) Model MPC OUTPUT LED'S OUTPUT RELAYS

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) Model MPC OUTPUT LED'S OUTPUT RELAYS HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004 TEL. (973)575-4004 FAX (973)575-4052 INSTALLATION & OPERATION MANUAL MODEL MPC GOLD SERIES TABLE OF CONTENTS Control Panel... 2 Understanding

More information

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ 08/50841/3 Issue 3 1 614 770 250 250 13 : 17 605 605 2kW 2.4kW CDE2Ti(B) (Fig.3) CDE2ECC(B) & CDE24ECC(B) (Fig.2) 2 3 4 LCD x o eco X Y eco

More information

User's Instructions. Alpha CB50

User's Instructions. Alpha CB50 User's Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage (From Boiler Serial No. 27B32500001) For Technical help or for Service

More information

Control solutions Biofloor

Control solutions Biofloor TEF234 Electronic room thermostat with display 230V & 24V COMAP proposes a new control system for heating and cooling underfloor. Consisting of a 6 or 10- channels controller (MCF234), analogic (TAF234)

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 5100 Premier Series 7-Day Programmable 2-Heat / 2-Cool Heat /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed

More information

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat MODEL 2000NC USER MANUAL Builder Series 5-2 Day Programmable Single Stage /Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS USER GUIDE VB0110 BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS *This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US

More information

Open Vented Condensing Boilers

Open Vented Condensing Boilers Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers User s Operating Instructions These instructions should be left with the user Dimplex Boilers 2008 CONTENTS SECTION DESCRIPTION PAGE 1.0 Using

More information

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035 Operating & Installation Instructions What is a programmable room thermostat?... an explanation for householders A programmable room

More information

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482 Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482 Content Overview, display, and symbols... 4 Info button... 7 Operating modes... 8 Switching the heating ON... 9 D.h.w. heating...

More information

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Battery Powered Electronic Room Thermostat Cat. No. TRT033 Battery Powered Electronic Room Thermostat Cat. No. TRT033 What is a room thermostat?... an explanation for householders A room thermostat simply switches the heating system on and off as necessary. It

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

425 Coronet Electro-mechanical Timeswitch User Operating Instructions 425 Coronet Electro-mechanical Timeswitch User Operating Instructions The 425 Coronet timeswitch is a single circuit central heating timeswitch able to switch ON and OFF twice every 24 hours. An advance

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series Premier Series MODEL 5000 USER MANUAL 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

prestige Control Application Supplement - TriMax

prestige Control Application Supplement - TriMax prestige Control Application Supplement - TriMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

AUTO CM CM USER GUIDE

AUTO CM CM USER GUIDE 1 2 3 4 5 6 7 AUTO CM701...2-6 CM707...7-11 USER GUIDE CM701 - USER GUIDE Description The Honeywell CM701 is a programmable room thermostat designed to control your heating system efficiently, providing

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction The tempo has been designed with simplicity in mind and is highly intuitive in its programming.

More information

Heating Controller SDC Remote Heating Controller DHC

Heating Controller SDC Remote Heating Controller DHC Heating Controller SDC Remote Heating Controller DHC OPERATING INSTRUCTIONS EN2H-0220GE51 R1111 EN2H-0220GE51 R1111 Contents Contents 1 Software version... 7 2 Safety instructions... 7 2.1 Intended use...

More information

RAYBURN SUPREME/NOUVELLE/355S USER INSTRUCTIONS ISSUE 4 Water Temperature Control Stat. http://www.oilstoves.co.uk/ 1 2 Contents 1. Introduction. 1 2. How Does it Operate? 1 3. Description of Controls.

More information

Installation & User s Instructions

Installation & User s Instructions Installation & User s Instructions 8 080 shown Part No. 00 day Wired Digital Programmer & Room Sensor Part No. 080 day Wireless Digital Programmer & Room Sensor Part No. 00 hr Wireless Digital Programmer

More information

CT1500, CT1501, CT1502, CT1503

CT1500, CT1501, CT1502, CT1503 Timer Thermostat Fuel Saver Heating-Only Thermostat and Wallplate or Heating/Cooling Thermostat and Subbase Models CT1500, CT1501, CT1502, CT1503 Heat Only CT1500 Heat/Cool CT1501 Central Electric Heat/Cool

More information

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series Introduction The Tempo has been designed with simplicity in mind and is highly intuitive in its programming.

More information

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05) 720 12 481-00.1R oiler Energy Management System FW 200 Operating Instructions for the User 2 US/CA Dear Customer, The controls are the brain of your heating system. We have set it at the factory so that

More information

SERVICE MANUAL New Electronic Cold Platform 2005.

SERVICE MANUAL New Electronic Cold Platform 2005. SERVICE MANUAL New Electronic Cold Platform 2005. All the parts included in this document are the property of Indesit Company S.p.A. All rights reserved. This document and the information it contains are

More information

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty UK ENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTION FORMAT DGT HE 199838 User instructions Please read the Important Notice within this guide regarding your

More information

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS. User Manual HEAT RECOVERY VENTILATORS MODELS: 1000 HE HE 1.3 2000 HE HE 1.8 3000 HE HE 2.6 3055 COMPACT 5585 COMPACT VB0021 READ AND SAVE THESE INSTRUCTIONS. VVI, 550 Lemire Blvd., Drummondville, QC, Canada

More information

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY Customizable programming options for every day, weekdays, weekends, or individual days. Smart recovery gradually adjusts indoor temperatures

More information

Vokèra OpenTherm 711 without external sensor connected

Vokèra OpenTherm 711 without external sensor connected Vokèra OpenTherm 711 without external sensor connected Setup guide to using the OpenTherm Control without an external weather compensation sensor fitted. If you are unsure if there is an external sensor

More information

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 with external sensor connected Vokèra OpenTherm 711 with external sensor connected Setup guide to using the OpenTherm Control with an external weather compensation sensor fitted. If you are unsure if an external sensor is fitted check

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

Watch Movement Specification and Drawing CHRONOGRAPH. Cal. YM62A. Movement Size. Casing Diameter. Ø 27.0mm. Height. 3.7mm. Battery Life.

Watch Movement Specification and Drawing CHRONOGRAPH. Cal. YM62A. Movement Size. Casing Diameter. Ø 27.0mm. Height. 3.7mm. Battery Life. Watch Movement Specification and Drawing CHRONOGRAPH Cal. YM62A Movement Size 12 Casing Diameter Ø 27.0mm Height 3.7mm Battery Life 3 years Date: 15/Dec./'17 Cal. YM62A Items Rev. Page Specifications 04

More information

ELECTRIC DESIGNER RADIATORS

ELECTRIC DESIGNER RADIATORS ELECTRIC DESIGNER RADIATORS RF4P RF6P RF8P RF10P RF12P RF14P RF4E RF6E RF8E RF10E RF12E RF14E INSTALLATION INSTRUCTIONS AND USER GUIDE Please read these instructions before installing or using this appliance

More information

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE Installation instructions For the competent person Installation instructions VRT 350 VRT 350 GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Installation instructions Authorised

More information

Leading Word on Lag Modules

Leading Word on Lag Modules Electronic Service Inc. KW Electronic Service Inc. and Viessmann, partners in heating technology. Controls newsletter, May 2002, Issue 2 T hank you to everyone who responded to our first edition of VITOTALK.

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION MODEL 5100 USER MANUAL Compatible with low voltage multi-stage heat/cool systems with up to two stages of heating and two stages of cooling. READ ALL INSTRUCTIONS BEFORE PROCEEDING 1 2 3 4 5 6 7 CONTENTS

More information

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

BrainQ RSC/2 USER MANUAL. BrainQ RSC/2 Thermostat 8G /10.05

BrainQ RSC/2 USER MANUAL. BrainQ RSC/2 Thermostat 8G /10.05 BrainQ RSC/2 USER MANUAL BrainQ RSC/2 Thermostat 8G.52.09.00/10.05 NL F I English Contents Control level Display and operating instruments...........................................................................-5

More information

WARNING Important Safety Information

WARNING Important Safety Information Premier Series Programmable Thermostats MODEL 5000 1 2 3 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information Additional Operation Features

More information

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1. User Guide HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.5 VB0122 VB0123 VB0126 VB0136 PLEASE READ AND SAVE THESE

More information

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - ACVMax 2015-10 Prestige ACVMax Control Sup 12-14-15_ACVMax_Control 12/15/15 7:36 AM Page 1 prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory

More information

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL M/A MANUAL ESRTPRF Wireless Programmable Room Thermostat, with Delayed & Optimum Start User and Installation Instructions INDEX User Instructions What is a Programmable Room Thermostat? 1 Introduction

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Dec Wirsbo CoSy Radio. Installation and Operating Instructions Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting

More information

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller

More information

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat. MAKING MODERN LIVING POSSIBLE User Guide ECtemp 550 Electronic Intelligent Thermostat www.eh.danfoss.com Table of Contents 1 Introduction............... 4 1.1 Safety Instructions........ 5 2 Settings.................

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF AOU 9RLFW AOURLFW R40A CONTENTS. DESCRIPTION OF EACH CONTROL OPERATION. COOLING

More information

Modulating clock thermostat

Modulating clock thermostat EN Digital timer thermosatat Modulating clock thermostat Installation and Service Manual 123189-AB Contents 1 Preface...4 1.1 General...4 2 Location of the installation...5 2.1 Position of the regulator...5

More information

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL THE EVOLUTION OF CONTROL APP & CLOUD PORTAL APP MAIN APP FUNCTIONS EMERGENCY Facilitates the work of installers and company maintenance operators. Allows control of the functions of all lights of the system.

More information

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS USER GUIDE HEAT RECOVERY VENTILATS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, AND ENERGY RECOVERY VENTILAT MODEL ERV 90H-V ECM VB0124 VB0125 VB0127 VB0137 PLEASE READ AND SAVE THESE INSTRUCTIONS These

More information

Control Application. Supplement - ACVMax

Control Application. Supplement - ACVMax prestige Control Application Supplement - ACVMax L I S T E D WARNING This document is intended to be used by a factory trained and qualified heating contractor or service technician only. Read all instructions

More information

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number SERVICE INSTRUCTION REFRIGERATION DISTRIPARTS AB BOX 501 S-562 80 NORRAHAMMAR Phone 036-31 80 00 Telefax 036-31 81 10 Telefax 036-31 80 88 Publication number 599 51 96-71 Rev. 04-04-20 SV/SERVICE DT/MA/AN

More information

G a

G a G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,

More information

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY THERMOSTAT PROGRAMMABLE 7-DAY THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Riello s weekly programmer.. This central heating control device is

More information

Battery Powered Electronic Programmable Room Thermostat

Battery Powered Electronic Programmable Room Thermostat Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035 Operating & Installation Instructions What is a programmable room thermostat?...an explanation for householders A programmable room

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Planet Super4F.S. User Instructions

Planet Super4F.S. User Instructions GB Planet Super4F.S. User Instructions USER INSTRUCTIONS VERY IMPORTANT! PLEASE MAKE SURE YOUR LOG BOOK ENCLOSED IS FILLED IN CORRECTLY. ALL CORGI REGISTERED INSTALLERS CARRY A CORGI ID CARD. BOTH SHOULD

More information

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight

More information

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating MAKING MODERN LIVING POSSIBLE TP7001 Range Electronic 7 Day Programmable Room Thermostat Danfoss Heating User Guide TP7001 Electronic 7 Day Programmable Room Thermostat For a large print version of these

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

RF Programmable Room Thermostat User Instructions

RF Programmable Room Thermostat User Instructions ESRTP4RF RF Programmable Room Thermostat User Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition

More information

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER Thank you for your purchase of our Microcomputer based Temperature Indicating Controller. This manual contains instructions

More information