1 H Y D R O C O U R S E T R E N C H H E A T I N G Natural convector trench heating system Modular design for bespoke applications Architectural floor grilles High efficiency finned tube element
2 Contents PAGE IDENTIFICATION Introduction 2 Authority 2 DESCRIPTION Hydrocourse Trench 2 Range 3 Features 3 Casing 3 Elements 3 Example A & B 3 Accessories 4 Grilles 4-7 Special options 4 PERFORMANCE 8 Correction factors 9 IDENTIFICATION Introduction This brochure provides comprehensive information about Dunham-Bush Hydrocourse trench heating, with guidance on selection, application, use and supply. Dunham-Bush Hydrocourse trench heating comprises powder coated steel casings, finned tube elements and satin anodized aluminium grilles. Hydrocourse provides natural convective heat and produces a warm air current which can be used to off-set local down draughts and heat losses. It is suitable for operation with pumped hot water systems. Authority Dunham-Bush Ltd operates a quality control system and is a registered company of Assessed Capability to BS EN 9001:2015 APPLICATIONS General 10 Selection 10 Using factors - Applications 1& 2 11 Expansion 12 Typical layout 13 Dimensions ENGINEERING SPECIFICATION General 25 Casings 25 Edge trim 25 Floor grille 25 Levelling screws 25 Finish 25 Elements 25 Working pressure & temperatures 26 Performance 26 Standard parts & accessories 26 Packing 26 CONSTRUCTION Handling 27 Storage 27 Preparation 27 Layout drawings 27 PRICES & CONDITION OF SALE Prices 27 Conditions of sale 27 Availability 27 Ordering 27 Delivery 27 TECHNICAL SUPPORT SERVICES Product support 27 DESCRIPTION Dunham-Bush Hydrocourse trench heating is manufactured in 22 standard models and in fixed lengths of 500mm, 1000mm, 1500mm, complete with telescopic mm casings and a mm trim length casings. The system comprises casings in black powdered coated steel, copper tube element with aluminium fins and rigid or roll satin anodized aluminium grilles. The standard finned element lengths are manufactured with 22mm O.D. copper tube and aluminium fins having a nominal spacing of 6mm. Some elements are also available with 15mm copper tube Casings and elements are sized to accommodate single or double runs of finned element lengths where appropriate, in progressive ascending output combinations. Return pipework options are available. 2
3 MODEL RANGE AND DIMENSIONS Range Standard casing models:- HTA-1 to HTA-10 Return pipework models:- HTA-1/P to HTA-10/P Fin types:- X = 60mm x 48mm W = 70mm x 76mm Y = 100mm x 70mm Z = 100mm x 100mm Features Built-in level adjustment Uniform heat distribution Minimal maintenance Silent operation Effective control of space heating Model Reference Casing Width Casing Height Fin Types (Height) HTA W-070 HTA WW-070 HTA WW-070 HTA YY-100 HTA W-070 HTA Z-100 HTA YZ-100 HTA YY-070 HTA WW-070 HTA ZZ-100 HTA-1P W-070 HTA-2P WW-070 HTA-3P WW-070 HTA-4P YY-100 HTA-5P W-070 HTA-6P Z-100 HTA-7P YZ-100 HTA-8P YY-070 HTA-9P WW-070 HTA-10P ZZ-100 Casing The casing type is defined by model reference; H - (Hydrocourse) TA (Transverse Aluminium Grille Bars) and the casing size type number. The P suffix denotes whether a casing is fitted with provision to accommodate return pipework, and the "S" suffix denotes whether a casing is a bespoke style. Example A Model HTA-2 comprises a 270mm wide, 100mm high case, with two runs of W element, size (70mm high x 75mm wide). Example B HTA-7P comprises a 340mm wide, 200mm high case, with provision for return pipework and a double run of element, consisting of one run of Y element size (100mm high x 70mm wide) and one run of Z element (size 100mm high x 100mm wide). Elements Standard element types X, W, Y and Z are manufactured in 22mm O.D. copper tube. The number of elements, orientation (by fin height) is defined by the number of letters before the fin size. e.g. W = single run of W element set at 70mm high YY = double run of Y element set at 100mm 3
4 ACCESSORIES AND BESPOKE OPTIONS Accessories End caps for finishing Hydrocourse trench casing runs, and 90 / 270 butt & mitred corners are available as standard in all casing sizes. Mitred joints are available to any specified angle at extra cost. Expansion joints and guides where specified. Typical expansion joint & pipe guides Grilles Floor grilles have a standard anodized finish in AA5 Satin Silver, made from aluminium spar profile Y-bar. Roll grilles are suitable for light applications, and rigid grilles are suitable for medium applications, as classified in BS EN 13264:2001. Special bespoke options available:- i) Stainless steel grilles are available for all casing sizes. ii) Special grilles are available for heavy duty loads and traffic upon request. iii) When specified linear grilles are available for suitable trench applications. iv) Curved grille is available for curved trench applications. v) Decorative wooden grilles are also available for domestic or architectural applications. vi) Fixed height and telescopic mounting feet can be made to order, and accommodate the void between the finished floor level and the depth of trench casing. vii) Note that non-standard grille dimensions may affect the performance. Case style HTA-7 (300mmH x 200mmW casing) with YZ-100 elements. 4
5 GRILLES Butt joint corner arrangement Mitred corner arrangement (90 standard, other angles on request) 5
6 GRILLES Bespoke Linear Grille Applications Stainless Steel U-Bar Roll Grille 6
7 PERFORMANCE Standard heat outputs to BS EN 442 with LPHW 70 C mean, 0.32kg/s water mass flow rate, ambient air at 20 C Casing Style Element Type Casing Width (mm) Casing Height (mm) Standard Output Qs (W/m) HTA-1 W HTA-2 WW HTA-3 WW HTA-4 YY HTA-5 W HTA-6 Z HTA-7 YZ HTA-8 YY HTA-9 WW HTA-10 ZZ HTA-1P W HTA-2P WW HTA-3P WW HTA-4P YY HTA-5P W HTA-6P Z HTA-7P YZ HTA-8P YY HTA-9P WW HTA-10P ZZ Standard outputs at T = 50K to BS EN 442 standard conditions (LPHW 75/65 C and ambient air 20 C) and water flow rate 0.32kg/s 2. For different LPHW temperatures, ambient air temperatures and water flow rates, refer to page 8. 7
8 PERFORMANCE Corrected output (Q c ) = Qs x F1 x F2 where Qc = Corrected output (W/m) Qs = Standard output at standard conditions (W/m) Water flow rate (kg/s) = Qs / (TF TR) x Cp where TF = water flow temperature ( C) TR = water return temperature ( C) Cp = specific heat capacity of water (kj/kg K) For most applications, Cp can be taken as kj/kg K Correction factor F1 for different water temperatures T (K) F1 T (K) F1 T (K) F1 T (K) F1 T (K) F Correction factor F2 for different water velocities Water Water F2 Water Water F2 Water Water F2 Water Water F2 Flow Rate Velocity Flow Rate Velocity Flow Rate Velocity Flow Rate Velocity (kg/s) (m/s) (kg/s) (m/s) (kg/s) (m/s) (kg/s) (m/s) Water velocity (m/s) based on elements with 22mm copper tube; contact Dunham-Bush for guidance on correction factors with 15mm tube elements. 8
9 SELECTION & APPLICATION General Dunham-Bush Hydrocourse trench heating is designed to cover a broad range of casing sizes, grille styles and outputs. Heat is emitted by natural convection and provides evenly distributed warmth, ideal for preventing down draughts on cold surfaces such as outside walls and glazing. Standard casings are supplied in fixed lengths of 500mm, 1000mm, 1500mm. Telescopic casings with an adjustment range mm length are supplied for made-to-fit installations Similarly, trim casings with a range mm can also be supplied for cutting on-site. Standard, telescopic and/or trim casings are fixed together on site to form a continuous heating run. End caps are available for finishing the ends of Hydrocourse trench cases. Where specified Hydrocourse trench heating can accommodate flow & return pipework. When using L.P.H.W or M.T.H.W as the heating medium in long lengths, consideration must be given to the change in output along the length due to the reduction in water temperature from flow water temperature to return water temperature. On long runs consideration must be given to accommodate the expansion of the element/pipework. Dunham-Bush can supply expansion bellows and guides upon request. Step 1. Select a model to suit to the desired dimensions that the floor void/trench will accommodate. Base the selection of the model firstly by the model s casings height. Trench heating is supplied with an additional height adjustment of up to 50mm (with factory-fitted M6x70 levelling screws) Adjustable casing supports can also be supplied for floor voids greater than 150mm in depth, up to the depth of 450mm. Special, bespoke casings can be considered contact your Dunham-Bush represetative. Step 2. Once the desired model is selected, calculate the nominal output per length, using the correction factors. Step 3. Decide the location of the trench heaters and consider floor grilles. If heaters are to be installed in areas of high foot traffic, rigid grilles are more suitable than roll grilles. The standard grille offered for all applications is the Y-Bar roll grille. Step 4. Consider finishes as well as control accessories; contact Dunham-Bush for further guidance. 9
10 10
11 SELECTION & APPLICATION Provision for expansion, general considerations. When the elements and tubing are connected to form a continuous run, provision must be made for the resulting expansion when the heating medium is applied to the system. It may be possible, in some circumstances, to arrange for a small amount of expansion to be taken up within the casing by allowing the pipework to float. But it is usually necessary to provide expansion bellows & guides to compensate for the expansion. As a basic rule the maximum float should not exceed 6mm. Because of the limited space available within the trench casings it is not always possible to fit proprietary expansion bellows, and for this reason Dunham-Bush offer purpose made expansion joints and suitable pipe guides. Quantity of Expansion Joints and Guides To decide on the quantity and suitability of Dunham-Bush expansion joints & guides for a particular application. The total amount of movement or expansion of the elements and tubing in the run being considered. This will depend upon the difference between the minimum installed and maximum operating temperature and the coefficient of the linear expansion of the tubing material. Each expansion joint & guide kit is capable of accepting up to 6mm maximum of expansion, i.e. 3mm from each end. 11
12 GENERAL ARRANGEMENT - CASINGS AND GRILLES 12
13 GENERAL ARRANGEMENT - ADJUSTABLE (TELESCOPIC) CASING SUPPORTS 13
14 HTA-1 SINGLE ELEMENT TYPE W-070 HTA-1P SINGLE ELEMENT TYPE W
15 HTA-2 DOUBLE ELEMENT TYPE WW-070 HTA-2P DOUBLE ELEMENT TYPE WW
16 HTA-3 DOUBLE ELEMENT TYPE WW-70 HTA-3P DOUBLE ELEMENT TYPE WW-70 16
17 HTA-4 DOUBLE ELEMENT TYPE YY-100 HTA-4P DOUBLE ELEMENT TYPE YY
18 HTA-5 SINGLE ELEMENT TYPE W-070 HTA-5P SINGLE ELEMENT TYPE W
19 HTA-6 SINGLE ELEMENT TYPE Z-100 HTA-6P SINGLE ELEMENT TYPE Z
20 HTA-7 DOUBLE ELEMENT TYPE YZ-100 HTA-7P DOUBLE ELEMENT TYPE YZ
21 HTA-8 DOUBLE ELEMENT TYPE YY-070 HTA-8P DOUBLE ELEMENT TYPE YY
22 HTA-9 DOUBLE ELEMENT TYPE WW-070 HTA-9P DOUBLE ELEMENT TYPE WW
23 HTA-10 DOUBLE ELEMENT TYPE ZZ-100 HTA-10P DOUBLE ELEMENT TYPE ZZ
24 ELECTRIC TRENCH HEATING Model: HTA-E Unit size: 200mm wide x 125mm deep. Element Enclosure: Electric IP 66 rated Levelling Feet: depth) M6x70 (1-50mm adjustment on casing Our range of electric trench heaters are an alternative option to the standard LPHW convectors. Natural convection is achieved from an electric element with outputs ranging from W. The electric heaters can have one of three standard selections for grille styles. Y-bar grille being the most common, to the I-Bar/U-Bar grilles for medium to heavy foot traffic. Available lengths and outputs: 800mm casing length outputs W 1000mm casing length outputs W 1200mm casing length outputs W 1500mm casing length outputs W 24
25 ENGINEERING SPECIFICATION The Hydrocourse trench heaters shall be manufactured by Dunham-Bush Limited, Downley Road, Havant, Hampshire, PO9 2JD. The models, style, numbers and quantities shall be as indicated in the schedule and/or on the drawings. The construction of all heaters must comply with the following specification. General Each trench heater shall consist of a sheet metal casing, heating coil. Where appropriate to the model, water control valves shall be fitted into the casing. Casing Construction Casings shall be constructed from 1.2mm mild steel panels, adequately stiffened to minimise distortion. All casings shall have rounded edges, for increased safety. Casing Dimensions Each model has its own unique dimensions, Our Hydrocourse heaters have a selection of depths and widths to suit all trench applications. Casing dimensions shall have a manufacturing tolerance of ±1mm. Fitted Grilles All fitted grilles shall be pencil proof, manufactured from aluminium alloy in either Y-bar or I-Bar profile. Our grilles are manufactured in either rigid sections to suit the Hydrocourse trench length, or Roll-up grille for continuous runs up to and including 3000mm in length on request we can use U-Bar stainless steel. Alternative option from our standard transverse grille is the linear option. Linear grille is only available in Y-bar aluminium in set lengths of 1.0m, 1.5m 2.0m. Curved grilles are an available option, a.dwg file is required at quotation stage. Please note that without a.dwg file, we are unable to proceed with an order until all information is received. Casing and Grilles Finish All mild steel casing components, casings and grilles shall be pre-treated before the application of polyester powder coating. Casing standard colour : Black 00 E 53, 10% gloss. Grille standard colour: Silver AA5 anodised finish. Colours to BS4800:1989. Other colours available on request. Elements Elements shall be supplied in single lengths of 15mm O.D. solid drawn copper tubes, expanded into single plate aluminum fins. Test pressures for coils only 10.5 barg cold test 7.0 barg max water pressure. 25
26 ENGINEERING SPECIFICATION Copper tube/aluminium finned elements Element types X, W, Y and Z consist of 22mm O.D. copper tube with (X) 60mm x 48mm, (W) 70mm x 75mm, (Y) 70mm x 100mm and (Z) 100mm x 100mm aluminium fins having a minimum thickness of 0.35mm. Outside diameter of tube shall be as listed below. Element Min Max Tube dia. O.D.mm O.D.mm 22MM MM - - All copper tube/aluminium finned elements shall have plain ends and shall be available in lengths of 1000 and 1500mm. Unless otherwise stated the finned length shall be 150mm less than the overall length, giving 75mm plain tube ends for connection to pipework (fittings by others). Working Pressure and Temperatures The working pressure and temperature and cold test pressure may be limited to those given for expansion joints and fittings used with elements. Element only Maximum working pressure 14.0 bar gauge. Maximum working temperature 175 C. Maximum cold test pressure 21.0 bar gauge. Anchors Where necessary, Anchors shall be provided by others. Performance Hydrocourse shall be capable of producing the heat outputs listed in the manufacturer s Product Catalogue, when installed in accordance with their recommendations. Heat outputs shall be derived from tests to BSEN 442. Standard parts 500mm, 1000mm and 1500mm fixed casings. 1000mm- 1500mm telescopic casings and mm trim lengths. Casings shall include two element supports, one baffle, captive nuts and screws. Grille trims shall be supplied in 2000mm lengths and floor grilles in lengths of 500mm, 1000mm, 1500mm, (roll grille only is also available in 3000mm) Standard Accessories End plates, 90 / 270 butt corner, 90 / 270 mitred corners and expansion joints. Special Accessories Fixed height and Telescopic mounting feet, height and width as per customer requirements. Packing Hydrocourse Trench components shall be properly packed and labelled. Expansion joints & guides When specified, expansion joints & guides shall be supplied to suit the element. Expansion joints shall be manufactured from gliding metal and shall have plain copper female ends suitable for forming a capillary joint. Maximum working pressure of 2 bar gauge and (cold) test pressure of 3 bar gauge. Expansion joint pipe guide kits are manufactured from 1.6mm mild steel and shall be provided for fitting each side of an expansion joint at intervals along the element run to ensure only axial movement. Guide clips shall be slotted to allow element grading. 26
27 CONSTRUCTION Handling The purchaser is responsible for off loading. Heaters are grouped together and loaded upon a pallet up to 2.0m x 1.2m. When a significant quantity of heaters is delivered, they may be palletised and shrink wrapped, so a fork lift truck or some form of lifting equipment is strongly desirable. Care should be taken to ensure the heaters are not dropped or knocked under any circumstances. Storage Heaters should be stored under clean, dry conditions. The shrink wrap should not be removed until heaters are required for installation, unless damage in transit is suspected. Note the purchaser must examine the heaters promptly upon receipt and any claims for damage will only be accepted if, at the time of delivery, the consignment note is endorsed with a note detailing the damage and counter signed by the transport driver. Installation details Hydrocourse heaters are supplied with a copy of the Installation, Operation & Maintenance Instructions, which provide full details for installing, connecting and commissioning the unit. Additional copies are available upon request, or can downloaded from Preparation A suitable trench void should be prepared ready to accept the trench heating system. The trench void should be straight, uniform and level and free from obstructions that encroach on the casing, grille trim or grilles. If the trench system is to be cast into the floor, the installer must take adequate precautions to protect the dimensional stability of the casing assembly. Suitably sized plywood shuttering must be fitted to the grille recess prior to casting taking place. PRICES & CONDITION OF SALE Prices Dunham-Bush Ltd do not issue price lists but will be pleased to supply a written quotation upon request. Condition of sale The standard conditions of sale appear on all quotation and order acknowledgement forms. Additional copies are available upon request. Availability Hydrocourse trench heaters are supplied direct from our manufacturing plant. The availability varies with demand and should therefore be checked at the time of ordering. Packaging Heaters are placed on the pallets and given individual labels for referencing and then they are shrink wrapped. Each heater is marked to show the model, figure number, serial number and any reference given on the order for site identification. This information also appears on the consignment note. Delivery to site Hydrocourse heaters are delivered to site in accordance with our Conditions of Sale. The purchaser is responsible for the off loading and proper safe storage. Ordering and enquiry detail To allow us to process your order promptly, please refer to any quotation we have supplied and any relevant correspondence. Please send your order to our Agent or Sales Engineer who provided the quotation, remember to include the coil handings as incomplete information will delay manufacturing process. TECHNICAL SUPPORT SERVICES Product support In the United Kingdom and Ireland, Dunham-Bush has a network of Sales Agents, situated at strategic locations, to provide local support. Pipework connections Coil connections are either 15mm/22mm O.D straight pipe. Local isolating and regulating valves are recommended. Observe the correct flow and return positions, to ensure the rated heat output. Wiring diagram A project specific wiring diagram is supplied separately along with the installation instructions for reference when connecting the remote components where specified. 27
28 Quality Dunham-Bush operates a quality control system and is a company of assessed capability to BS EN ISO 9001:2015 Whatever the product, wherever its eventual destination, Dunham-Bush design and manufacturing policy has always been firmly based on technical quality. Other Dunham Bush products Series AM cased fan convectors Series BM concealed fan convectors Series CM cased fan convectors Series 600 ceiling tile heaters Series SL slim-line fan convectors Evolution radiant panels Evo-Lite radiant panels Dunham Strip radiant panels Lynx fan coil units Panther fan coil units Leopard fan coil units Cougar fan coil units Puma fan coil units Ocelot fan coil units Aerocourse fan-assisted trench heating Finvector perimeter sill-line heating Series UH unit heaters System LST low surface temperature radiators Sentry air curtains Sentinel air curtains BS EN ISO 9001: 2008 Manufacturer reserves the right to change any product specification without notice Dunham-Bush Ltd Downley Road Havant Hampshire PO9 2JD Tel Fax info@dunham-bush.co.uk C May 2018
Series CM. Cased fan convector Sill-Line 600mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW C heating medium
Series CM Cased fan convector Sill-Line 6mm high 7 sizes and 3 heating coil options 1-13kW output with LPHW 5-13 C heating medium CONTENTS IDENTIFICATION Identification Introduction 2 Authority 2 Description
More informationS E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S
S E R I E S B M C O M F O R T, A V A N T - G A R D E & L S T F A N C O N V E C T O R S Concealed chassis fan convector with range of 8 standard models Each model available in 9 sizes with 4 heating coil
More information(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.
System LST Low Surface Temperature Natural Convector Installation Instructions Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 (Global) www.dunham-bush.com Document
More informationOcelot Fan Coil Units
Ocelot Fan Coil Units Installation, Operation and Maintenance Instructions. Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 PDS-1200 1200-F-02 0258 58-00 (Global)
More informationSERIES BM. Concealed Fan Convector
SERIES BM Concealed Fan Convector Contents IDENTIFICATION Introduction Authority PAGE DESCRIPTION Range -4 Composition Features 3 Accessories 4-10 PERFORMANCE 11-13 Heat outputs-lthw Correction factors
More informationPanther Fan Coil Units
Panther Fan Coil Units Installation, Operation and Maintenance Instructions. Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 Fax. 023 9245 3601 PDS-1200 1200-F-02 0226-04 (Global)
More informationInstallation, Operation and Maintenance Instructions Document Ref:
Panther Fan Coil Units Installation, Operation and Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 126-000-001-C UK:www.dunham-bush.co.uk
More informationInstallation, Operation and Maintenance Instructions Document Ref:
Leopard Fan Coil Units Installation, Operation and Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 129-000-001-A UK:www.dunham-bush.co.uk
More informationInstallation, Operation & Maintenance Instructions Document Ref:
Lynx Fan Coil Unit Installation, Operation & Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 131-000-001-B UK:www.dunham-bush.co.uk
More informationWIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.
Puma Fan Coil Units Instructions.. Installation, Operation and Maintenance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD Tel. 023 9247 7700 PDSPDS-12001200-F-02440244-02 Fax. 023 9245
More informationMetropolitan high output natural and powered trench heaters
Metropolitan high output natural and powered trench heaters High output trench heaters Typically used in large glazed areas to reduce glazing losses, these units are the perfect way to enhance comfort.
More informationP R O D U C T G U I D E LST
P R O D U C T G U I D E LST Radiators Radiant Panels Fan Convectors Door Curtains Trench eating Perimeter eating Fan Coil Units Unit eaters Chillers Welcome Comfort to the Zone ICONIC E AT I N G A N D
More informationInstallation, Operation & Maintenance Instructions Document Ref:
Series AM Fan Convectors Installation, Operation & Maintenance Instructions Document Ref: Dunham-Bush Ltd, Downley Road, Havant, Hants PO9 2JD 023 9247 7700 info@dunham-bush.co.uk 121-000-001-A UK:www.dunham-bush.co.uk
More informationEfficient Cooling and Heating. Flexibility Is The Key
Lynx Energy efficient fan coil unit Chilled water cooling & hot water heating Waterside control with variable air volume Commercially quiet with excellent acoustics Programmable communication control systems
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TRENCH HEATING TUBULAR RADIATORS GILLED TUBE HEATING Introducing the new, simply better, Trench Heating range. Equally at home in commercial buildings, contemporary and traditional
More informationINTRODUCTION Flexibility Is The Key Simple Access For Maintenance
Cougar Energy efficient slimline 180mm fan coil unit Chilled water cooling & hot water heating Waterside control with variable air volume Commercially quiet with excellent acoustics Programmable communicating
More informationPanther Fan Coil Unit
Panther Fan Coil Unit Energy Efficient EC Motors 280mm Deep Chassis Horizontal Fan Coil Unit INTRODUCTION The Panther, manufactured by Dunham-Bush is an adaptable, easy to use fan coil unit, that performs
More informationSill Line Perimeter Casing. Warmline Trench Heating. Vectair Natural Convectors. Spirally Wound Gilled Tube
Sill Line Perimeter Casing Warmline Trench Heating Vectair Natural Convectors Spirally Wound Gilled Tube Introduction 1 Introduction Sill Line Perimeter Casing Sill Line Selection Procedure Warmline Trench
More informationTRENCH HEATERS COMMERCIAL/DOMESTIC INNOVATIVE VENTILATION & HEATING
TRENCH HEATERS COMMERCIAL/DOMESTIC A guide to Trench Heaters, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk OUR TRENCH HEATER
More informationProviding Natural Solutions to Heating
Designed and Manufactured in Great Britain Product Range Sill-Line Perimeter Casing Warmline Trench Heating Vectair Natural and Fan Assisted Convectors Spirally Wound Gilled Tubing Providing Natural Solutions
More informationUK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS
UK PRICE GUIDE January 2009 Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS CONTENTS Introduction 2 Round Top Range 3 Compact Range 5 Low Surface Temperature Range
More informationLinear Floor Heaters
Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement
More informationRittling Element. Catalog
Hydronic Heating Fan Coils Radiant ceiling systems Rittling Catalog Water Source Heat Pumps Zehnder decorative radiators Heating and cooling ceiling systems Comfortable indoor ventilation Clean air solutions
More informationSpecialists in Bespoke Trench Heating Tel:
Specialists in Bespoke Trench Heating Natural Convection Trench Heating Wet systems Natural Convection Trench Heating Electric Element Fan Assisted Trench Heating Fan Assisted Trench Heating and Cooling
More informationModula Standard Performance
the future of space conditioning Modula Standard Performance heating panel Application Commercial, hospitals, hotels, schools, shops, sports halls, offices, laboratories, food industry etc. Installation
More informationBELGRAVIA Classic (Vertical Units) - Technical Data Sheet
S & P Coil Products Limited BELGRAVIA Classic (Vertical Units) - Technical Data Sheet BELGRAVIA CLASSIC: CONSTRUCTION Each Belgravia Classic unit comprises a sheet metal case, fitted with inlet and outlet
More informationRecessed. Air Curtain. Fig 1. Recessed air curtain
the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable
More informationINTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold
RADIANT PANELS TRENCH PERIMETER GRILLES ELEMENTS PIPER FARM, BROMLEY GREEN ROAD, ASHFORD, KENT. TN26 2EF TEL: 01233 733308 FAX: 01233 733883 E-MAIL: sales@feukltd.com RADIANT PANEL RANGE INTRODUCTION HOW
More informationThe new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION
The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION Experience the external venetian blind 80 S in action! www.warema.com/80s The new WAREMA external venetian blind 80 S PROVEN THINGS
More informationConvectors Steam / Hot Water November, 2009
Convectors Steam / Hot Water 13-111.3 November, 2009 TABLE OF CONTENTS I. Model Nomenclature...3 II. Design Benefits... 4-5 III. Typical Piping Arrangements....6 IV. Correction Factors A. Steam...7 B.
More informationOptimal work climate with open doors. Industrial air curtains Model IndAC
Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being
More informationPerimeos. Ceiling Recess. decor. systems
Ceiling Recess decor systems Ceiling Recess Perimeos is a revolutionary ceiling perimeter solution, for concealing blinds and curtain tracks. A key feature is the SpeedClip mounting channel. This allows
More informationFORCEFLOW. 900 Series Fan Convectors
ORCELOW 900 Series an Convectors ORCELOW 900 SERIES WHY USE N CONVECTOR? an Convectors have three big advantages over similar heating solutions: they require little maintenance, they occupy much less wall
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More informationRADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING
RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED
More informationAirflex Radial & ISO Thermal pipe
Airflex Radial & ISO Thermal pipe Semi rigid ducting Key Features Zero leakage ensures highest performance 70% time saving on installation Interchangeable ducting system (75mm round / 51mm x 114mm oval)
More informationHydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econo-Line Enclosures
Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econo-Line Enclosures Catalog Zehnder decorative radiators Heating and cooling ceiling systems Comfortable indoor ventilation
More informationRittling Fanvector. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air
Rittling Fanvector Installation, Operation and Maintenance Heating Cooling Fresh Air Clean Air i Arrangements 1 General information 1 Dimensions and data 2 Installation 6 Wiring diagram 9 Operation 10
More informationDARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES
SECTION 15830 HEATING & COOLING TERMINAL UNITS PART 1 DESIGN DIRECTIVES 1.1 DESIGN CRITERIA A. All fan coil units shall be sized to meet design load while operating at medium speed. In extreme noise sensitive
More informationRADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING
RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED
More informationStatic cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection
DS 4094 E 05.2007/1 Technical Selection Main features 2 Preliminary remarks 3 Construction design 3 Main dimensions and materials 3 Design data 3 Layout example 5 Design specifications 8 Installation instructions
More informationSECTION (15767) - UNIT HEATERS
SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationCaice Attenuator Selector - Specifier Edition
Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels Efficiency Energy Saving Heating Cooling Fan Unit Acoustic Performance Guarantee Modular Product Selection Low Noise Levels
More informationAluminium Curtain Tracks
Aluminium Curtain Tracks Hand-drawn and Corded Tracks The brand for curtain accessories The brand for curtain accessories Your Curtain Tracks and Renaissance Your time is valuable. So you need to choose
More informationLOW SURFACE TEMPERATURE RADIATORS
JULY 2017 LOW SURFACE TEMPERATURE RADIATORS www.qrl-radiators.com/lst Page 03 LST RANGE SUMMARY Page 0-0 LST RANGE SPECIFICATIONS Page 0 RESISTANCE DIAGRAM Page 0 MOUNTING DETAILS Page 10 DRILLING CHART
More information3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater
Selectable Wattages, Back Cans, And Power Disconnects Furnish and install Electric Forced Air Heaters, Series 3380 where specified. The heaters shall be constructed of a heavy gauge steel housing. The
More informationFloor convectors LINE LINE ВНУТРИПОЛЬНЫЕ КОНВЕКТОРЫ
Floor convectors LINE LINE ВНУТРИПОЛЬНЫЕ КОНВЕКТОРЫ About company ON THE BASIS OF EUROPEAN STANDARDS AND THEIR ACCURATE EXECUTION AS WELL AS TAKING INTO ACCOUNT CONSTANTLY GROWING ENERGY PRICES, COMPANY
More informationInstructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System
Instructions for the BASIC Air Handling System, Sizes 004 055 1. General 1.1 Description of the System The BASIC System is a complete modular air handling unit. The unit consists of blocks, i.e. a number
More informationWARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes
WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure
More informationFill Point, Level Gauges, and Control Range
Fill Point, Level Gauges, and Control Range Page 1 Contents Fill Points, Level Gauges, and Control Equipment... 3 Fill Point Cabinets... 4 Single Tank Cabinet... 5 Twin Tank Cabinet... 6 Three Tank Cabinet...
More informationPRODUCT SPECIFICATION FireMaster Plus Concertina
PRODUCT SPECIFICATION FireMaster Plus Concertina 1 GENERAL 1.1 Scope Coopers FireMaster Plus Concertina active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated, delivered,
More informationG-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA
G-Series Cooler COUNTERTOP COOLER Part No.11IPA-061000 Instruction Manual FOR YOUR FUTURE REFERENCE This easy-to-use manual will guide you in getting the best use of your cooler. Remember to record the
More informationINTERNAL FRAMING PROFILES
INTERNAL FRAMING PROFILES Ceiling Furring Sections Dry-Wall Partitioning Sections Angle Beads And Accessories About the Hadley Group Hadley Industries is one of Europe s leading manufacturers of cold rollformed
More informationEnriching Environments
Enriching Environments 2 Enriching Environments We understand the difference an improved internal environment can make 3 Contents 4 5 6 7 8 9 10 11 About us Heating and cooling coils Fan convectors Trench
More informationCitrine. Low Depth. Features: Applications:
Citrine Low Depth 20 54 Fixed/adjustable round recessed LED Down Light. beam angle 20. colour temperature as Ideal to use in Hotels, Toilets, Under Counters, Showrooms and Display Areas. Fixed and adjustable
More informationACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS
ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS WWW.COOPERSFIRE.COM VII FIRE ACTIVE FIRE CURTAIN BARRIER FOR YOUR HOME AND COMMERCIAL PROPERTY. From architects to homeowners to commercial
More informationVARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8
VARICOOL Velum System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8 All legal and technical information was compiled to the best of our knowledge
More informationAXIOM L CANOPY Installation Guide
CI/SfB (35) Xy AXIOM L CANOPY Installation Guide June 2016 1 PREPARATION AXIOM L CANOPY COMPONENTS Item Nr. Description CS 534205 AXIOM L Profile (78,5 mm height) SUSPENSION POINTS Suspension points should
More informationinstallation, operation & Maintenance manual Floor-mounted Induction units
installation, operation & Maintenance manual Floor-mounted Induction units built on innovation induction units- fmfby/ fmlby/ fmtby Floor-mounted induction units FMFBY, FMLBY, & FMTBY are designed for
More informationAUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1
PRODUCT DATA SHEET AUTOMATIC FIRE CURTAIN FM 1 AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1 FM-1 fire curtains are used where, if there is a fire, it is necessary to create a temporary barrier within an opening
More information1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationCooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation
Cooling and heating systems Static cooling ceiling system SKS-/3 DS 10 E 01.010 Static cooling ceiling system SKS-/3 Main features Preliminary remarks / Applications 3 Main dimensions and materials 3 Construction
More informationUNITAIRE IV FAN COIL UNITS
UNITAIRE IV FAN COIL UNITS High Quality Engineered Fan Coils Since 1931 1 UNITAIRE IV ROOM FAN COIL UNITS Always an industry leader AIRTHERM has earned a reputation for m a n u f a c t u r i n g innovative,
More informationPedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk
Pedestal Range Installation and user manual Kiosk Trafalgar Tube Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3
More informationPolaris-I-60. active chilled beam. the future of space conditioning
the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,
More informationGCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER
G-Series Cooler GCG-10 UPRIGHT COOLER Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual Manual is for the following models: GCG-10-N33EB G-10-N33EB Instruction Manual GCG-10
More informationBand Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices
Band Heaters Mica Insulated Band Heaters (HM) Ceramic Insulated Band Heaters (KHM) Rectangular Band Heaters, Strip, Ring and Flat Heaters Protection Housings (WSM) Cast Heaters, Band, Flat or Custom Insulating
More informationG-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA
G-Series Cooler UPRIGHT COOLER Part No.11IPA-062800 Instruction Manual FOR YOUR FUTURE REFERENCE Thank you for using our product. This manual will guide you in getting the best use of your cooler. Remember
More informationCAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING
Page 1 Fig. 1 A typical concealed sampling installation. The capillary (or drop pipe sampling point assembly) places the sampling point in the same position normally occupied by a point type smoke detector.
More information1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material
1. Description General The cooler is used for cooling of water, oil or other liquid by use of air. The liquid is passing in the tubes where it transfere the energy to the air via the fins on the outside
More informationEN transition from BS 1387 Structural & Conveyance Business
Corus Tubes EN 10255 transition from BS 1387 Structural & Conveyance Business EN 10255 A smooth transition with Corus Install Contents 1 Introduction 2 The new standard 4 Detailed comparison 7 Comparison
More informationFor more information on Smart Architectural Aluminium visit The art of creative living. alitherm windows & doors
The art of creative living alitherm windows & doors Beautiful windows that complement your home Designed to conserve warmth & energy Alitherm windows and doors have been designed to reduce heat loss by
More informationSAX. Window & Wall Fans
SAX Window & Wall Fans features & benefits The SAX is a stylish, high performance range of axial flow fans which provides powerful extract of air through windows, walls, ceilings and panels for a variety
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction
More informationCopperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user
Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user Copperad QA/IOM/58 Issue 2 1 GENERAL 1.1 GENERAL DESCRIPTION This manual
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes 1. Hydronic baseboard radiators. 2. Hydronic finned-tube radiators. 3. Hydronic convectors. 1.2 SUBMITTALS A. Product Data: Include rated capacities,
More informationSargasso Range. A new range of radiant panels for heating commercial applications
Sargasso Range A new range of radiant panels for heating commercial applications How radiant panels work Radiant panels provide heating solutions for a wide range of applications. Sargasso Radiant Panels
More informationRESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators
RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING www.b Unique, slim-design baseboard radiators The RESCOM 2100 system is unlike traditional baseboard heating systems. Smooth flat panels are easily secured
More informationWOLF WARM AIR CURTAIN
TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring
More informationSAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts
Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products
More informationPhotography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE
Photography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE 2 Architect: Pettes et Sagnes SYSTEMA_TECHNAL_EN.indd 2 Photography: R. César 04-03-2014 17:00:07 SHOP AND OFFICE FITTINGS, simple
More informationinstallation, operation & Maintenance manual Floor-mounted Induction units acb 30/35
installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 built on innovation acb 30 & 35 Active Chilled Beam Models ACB30 & ACB35 are designed for installation in the ceiling
More informationECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance
TOP ECOSMART TWINFANS (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use Installation and Maintenance The EMC Directive 2014/30/EU The Low Voltage directive 2014/35/EU INDOOR USE ONLY Introduction
More informationCork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award
Cork Institute of Technology Higher Certificate in Engineering in Building Services Engineering Award Instructions Answer FIVE questions, All questions carry equal marks. (NFQ Level 6) Autumn 2006 Building
More informationTrench Heating. Katherm NK
Trench Heating Katherm NK Unbeatable advantages Katherm NK at a glance Details Choice of grilles and possible geometries Controller models Heat output Dimensions Benefits for you! Calculation program (ext.
More informationAegean Range. A new range of fan coils for heating and cooling commercial applications
egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)
More informationPRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex
PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex 1 GENERAL 1.1 Scope Coopers FireMaster NVS Horizontal Simplex active fire curtain barrier assemblies ( Fire Curtains ) are to be designed, fabricated,
More informationOptimax Refrigerated Retail Merchandisers
V Optimax Refrigerated Retail Merchandisers MODEL NUMBERS RMR65E RMR100E RMR130E RMR65S RMR100S RMR130S RMR65SW RMR100SW RMR130SW Assisted service 650 wide Assisted service 1000 wide Assisted service 1300
More informationWEAVE RADIANT TEXTILE PANEL. Credit Reimann Architecture
RADIANT TEXTILE PANEL Credit Reimann Architecture Developed in conjunction with Kvadrat Soft Cells, Weave radiant textile panels by Price provide thermal and acoustic comfort as well as infinite design
More informationSpace Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk
Space Saver Installation and user manual SS3 SS5 SS7 SS9 Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3 Important
More informationTrench Heating. Katherm QK with EC Technology
Trench Heating Katherm QK with EC Technology Unbeatable advantages Katherm QK at a glance Details Choice of grilles Controller models Heat output Dimensions Benefits for you! Calculation program (ext.
More informationCHH - Active Chilled Beam. Halton CHH. Active Chilled Beam
Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal
More informationSurface Temperature Tests on an LST Fan Convector
Surface Temperature Tests on an LST Fan Convector BSRIA Report 59569/1 Edition 2 This report supersedes Report 59569/1 dated 29 July 2016 Carried out for Smiths Environmental Products Ltd. By Alf Russell
More informationat in Bathroom radiators are where fashion and function come together in perfect harmony. With everything
128 Bathroom radiators are where fashion and function come together in perfect harmony. With everything from a choice of Ladder rails in a selection of sizes and colours, to the latest technology of infrared
More informationBS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.
FIRE RESISTANT CABLES FP600 FIRE RESISTANT CABLES FP600 BS7346-6 FP600 > Prysmian FP600 is a unique enhanced performance fire resistant power cable, designed specifically to meet the more onerous fire
More informationOur Pedigree. Smart Systems is a member of the internationally renowned Aliplast Group.
Assuredly ALITHERM Our Pedigree Smart Systems has over the past 25 years grown to become one of the UK s leading systems company with a reputation for product innovation, design expertise and quality in
More informationFIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION
FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION MEANS OF ESCAPE PROTECTION CASE STUDY: SSE HYDRO GLASGOW UK
More informationHydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels
Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels Catalog INTRODUCTION Zehnder Alumline: provides optimal comfort and energy
More informationWe have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems
We have some on stock... GEA MultiMAXX Prompt Unit Heaters Data & Facts GEA Heat Exchangers / HVAC Systems Short Description/Overview of Capacity Quick solution for heating of industrial halls For more
More information