energy efficient air curtains technical data and controllers
|
|
- Erika Austin
- 6 years ago
- Views:
Transcription
1 energy efficient air curtains technical data and controllers
2 Versatile are delighted to introduce the following door curtains manufactured by LSA. LSA are a market leader in Europe in the manufacture of quality energy efficient door curtains. Versatiles aspiration to source products like LSA and provide the most energy efficient, aesthetically pleasing indoor climate control solutions Why Chose the LSA Product? Low flow temperatures 60/40 degrees Stylish, Being Manufactured in high quality materials including stainless steel by top European designers Reliability by using EBM fans which also contribute to ease if installation All wiring is plug and play, the installer has no necessity to open the casing Other products available from the Versatile range: Indoor climate control Radiators Radiant heating & cooling Radiator valves Heat recovery systems Air handling systems Active cooling Control valves Trench heating (Heating / Cooling) CO2 Control Heat pumps & pipework For further details please visit our web site on: or Phone: or alternatively sales@versatile.ie
3 air curtain range technical data and controllers > Effect > Cassette Effect > Dual Effect > Colum Effect > Wing Effect > Nouveauline > Rondell > Indu Effect > Controllers Plug & Play > Correction Factors
4 > Effect Air Curtains for every interior
5 Technical Data > Effect Type Air volume m 3 /hr Heating capacity water 60 /40 kw ** Water resistance 60 /40 Pa Water connections 60 /40 female thread Electric heating capacity 400 V/kW Electric fan supply Nominal capacity Volt kw A Sound pressure db(a)* Weight kg Effect S Recommended blowout height max m 1000 P 1500 P 2000 P P E 1500 E 2000 E E /6/9 4/8/ Effect M Recommended blowout height max m 1000 P 1500 P 2000 P P E 1500 E 2000 E E /6/9 4/8/ Effect G Recommended blowout height max m 1000 P 1500 P 2000 P P E 1500 E 2000 E E /10/15 7,5/15/22,5 10/20/30 11/22/ Effect GX Recommended blowout height max m 1000 P 1500 P 2000 P P 3000 P Effect GXX Recommended blowout height max m x 1 1 /4 2 x 1 1 / P 1500 P 2000 P P 3000 P x 1 1 /4 2 x 1 1 /4 2 x 1 1 /4 2 x 1 1 / * Measured at a distance of 3 metres. Technical changes reserved ** LSA air curtains are supplied for a warm water supply with a temperature of 60 C and a return temperature of 40 C, inlet temperature +20 C. It is not necessary to supply the air curtain with other heat exchangers. See conversion table for other water temperature supplies and example below. T a Water C 100/80 90/70 80/60 70/50 60/40 55/35 T a air +15 C +18 C +20 C > Example The Effect M 2000 P60/40 gives 20.8kW with an air inlet temperature of 20 o C. If the system gives water temperatures of 90 o /70 o C then the factor is The capacity will become 2.17x20.8 = 45.14kW. This amount of energy is usually not relevant! Installing a three-way valve the outlet temperature and the necessary amount of energy will be varied and optimally adjusted to the number of revolutions of the fans. 1
6 > Effect length dimensions > Effect standard available in the colours: mm mm mm mm mm > Effect S/M/G GX/GXX > Effect 260 mm 450 mm > Effect Supplied with 60 /40 C warm water heater or electric heating as standard. See conversion table for other water temperature supplies. > Effect The outlet lamella can be adjusted in five different positions: The outlet vanes can be adjusted to suit different indoor requirements: Vertical air flow At 10 and 15 inwards, for use in the heating season At 10 and 15 outwards, for use when air conditioning is operating Other RAL colours available on request > Effect The electronic controller is suitable for connection to a solenoid valve and allows summer or winter operation for year round comfort. Can be connected to a building management system if required. > Effect A two or three-way valve can be easily connected to the warm water connections. > Effect Installation kits supplied assembled for units for ceiling void (BP) and flush with ceiling units (GP). > Effect Dust particles go no further than the micro perforated inlet grille which is easily cleaned by either wiping clean with a dry cloth or vacuuming. > Effect Available in 5 different lengths as standard. 2
7 > Cassette Effect Recessed air curtain range > Dual Effect
8 Technical Data > Cassette Effect Model Air quantity Heat output at PWW 60/40 C Water volume resistance Water connections Output of electric heating at 400V Electric connections, fans, rated output Sound level min/max Weight m 3 /h kw** kpa female thread kw Volt 50Hz kw A db(a)* kg Cassette Effect S Recommended blow-out height max m S 1.0 / S 1.2 S 1.5 / S 1.8 S 2.0 S 2.4 / S x 1/2 2 x 1/ /53 40/54 40/55 40/ S-E-1.0 / S-E-1.2 S-E-1.5 / S-E-1.8 S-E-2.0 S-E-2.4 / S-E /6/9 4/8/ /53 40/54 40/55 40/ Cassette Effect M Recommended blow-out height max m M 1.0 / M 1.2 M 1.5 / M 1.8 M 2,0 M 2.4 / M /54 40/55 40/56 40/ M-E-1.0 / M-E-1.2 M-E-1.5 / M-E-1.8 M-E-2.0 M-E-2.4 / M-E /6/9 4/8/ /54 40/55 40/56 40/ Cassette Effect L Recommended blow-out height max m L 1.0 / L 1.2 L 1.5 / L 1.8 L 2.0 L 2.4 / L /55 40/56 40/57 40/ L-E-1.0 / L-E-1.2 L-E-1.5 / L-E-1.8 L-E-2.0 L-E-2.4 / L-E /10/15 7.5/15/ /20/30 10/20/ /55 40/56 40/57 40/ * Measured in 3 metres distance. Subject to technical alterations ** LSA air curtains are delivered for heat exchangers 60/40º C and an intake air temperature of +20 C. The LSA air curtain also works excellently in the early or late season. Installing a thermostat limits the blow-out temperature and thus adjusts the needed amount of energy to the amount of air. T a Water C T a Air +15ºC +18ºC +20ºC 100/80 90/70 80/60 70/50 60/40 55/ For different water temperatures see the conversion table. 4
9 260 mm Cassette Effect S/M/L > Cassette Effect length dimensions mm mm mm mm mm mm mm > Cassette Effect Ready for connection, with self supporting sheet steel housing with no screws visible in sight area, powder-coated in white RAL colour 9016 (PVC - free), other RAL colours available on request. Sound and heat- damping internal insulation. > Cassette Effect Specially designed to be installed flush with the ceiling. > Cassette Effect All connections made sideways. The necessary mounting space is only 26cm. Flush installation to the ceiling tiles is possible. Width 70 cm. Parallel air inlet preparation. A two or three-way valve can be easily connected to the warm water connections > Cassette Effect Supplied with 60/40ºC warm water heater or electric heating as standard. See conversion table for other water temperature supplies. > Cassette Effect The double outlet vanes can be adjusted in five positions: Vertical air flow At 10º and 15º inwards, for use in the heating season At 10º and 15º outwards, for use when the air conditioning is operating New Double outlet vanes Adjustable to 5 positions A IN A 1/ OUT
10 > Dual Effect > Energy-saving air curtain with double-jet air flow Colum Effect
11 Technical data > Dual Effect Model/ Length of unit Warm air quantity Circulating air quantity Total air quantity Heat output at PWW 60/40 C Water volume resistance Water connections Electric connections, fans, rated output Sound level min/max Weight mm m3/h m3/h m3/h kw kpa female thread volt 50Hz kw A db(a)* kg Dual Effect S Recommended blow-out height/projection height max m S /53 48 S /54 65 S /55 92 S / Dual Effect M Recommended blow-out height/projection height max m M /54 52 M /55 70 M /56 98 M / Dual Effect L Recommended blow-out height/projection height max m L /55 60 L /56 80 L / L / * Measured in 3 metres distance. Subject to technical alterations. LSA air curtains are delivered for heat exchangers PWW 60/40º C and an intake air temperature of +20 C. The LSA air curtain also works excellently in the early or late season. Installing a thermostat limits the blow-out temperature and thus adjusts the needed amount of energy to the amount of air. front view 260 bottom view top view A 40 side view IN OUT circuid board connecting box revision 7
12 Dual Effect S/M/L > Dual Effect length dimensions > Dual Effect standard available in the colours: mm mm mm RAL 9016 (Traffic White) RAL 9006 (White Aluminium) Other RAL colours available on request mm > Dual Effect height S/M/L > Dual Effect 260 mm Ready for connection double-jet door air curtain device with self-supporting sheet steel housing with no screws visible in sight area, powder-coated (PVC - free). Access door for maintenance hidden behind the intake screen. Double air outlet with adjustable aluminium vane (anodized) for optimal air flow. Inlet grill is in same colour as the device, made of perforated plate for filterless and easy to maintain operation. New Adjustable outlet vane flush with the device s underside In 5 levels adjustable > Dual Effect Energy-saving double-jet door air curtain with or without heating. Only two-thirds of heating power will be required compared to standard air curtains. Sound- and heat- damping internal insulation. Shock-mounted and separately driven centrifugal fans with thermostat relays for motor protection. High-efficiency heat exchanger for low temperature heating, made of copper tube with integrally moulded aluminium vanes. Threaded hole M8 for ceiling mounting. The electronic 5 level comfort control Tronic P for warm heating heating provides standard summer/winter function. An solenoid or a pump with up to 2.5 A could optionally be controlled in the winter-position. It is possible to shunt up to 12 devices. The control panel provides a tree contact (for external release), which can be connected to every GLT or DDC. A 20m cable with integrally moulded plug (excess lengths available upon request) is included in delivery. > Dual Effect For energy saving reasons, a thermostatic 2-way or 3-way valve can be ordered as reasonable to keep the intake air temperature on an even level. It is delivered as loose enclosure and can be fitted easily by the customer. 8
13 > Colum Effect Design Air Curtains
14 Technical Data > Colum Effect Type Length/ Height mm Air volume m3/h Water resistance kpa Heating capacity 60/40 C kw Water resistance kpa Water connections female thread Electric heating capacity 400 V kw Electric fan supply Nominal capacity Volt 50Hz kw A Sound pressure db(a)* Weight kg Colum Effect 2000 recommended blow-out height/projection height max 2.50 m , , ,48 2,62 6,40 12,44 3,01 11,60 17,40 23,30 30,90 34,90 3,18 0,84 2,28 4,66 1,03 0,54 0,89 1,08 1,35 1,62 2,36 3,54 4,72 5,90 7, E 2001,5 E 2002 E 2002,5 E 2003 E /6/9 4/8/12 10/20/30 0,54 0,89 1,08 1,35 1,62 2,36 3,54 4,72 5,90 7, Colum Effect 3000 recommended blow-out height/projection height max 2.80 m , , ,17 3,79 10,83 19,23 5,07 17,40 23,30 34,90 40,70 52,30 5,63 1,21 3,81 7,16 1,72 0,81 1,08 1,62 1,89 2,43 3,54 4,72 7,08 8,26 10, E 3001,5 E 3002 E 3002,5 E 3003 E /6/9 4/8/12 10/20/30 10,7/21,4/32 0,81 1,08 1,62 1,89 2,43 3,54 4,72 7,08 8,26 10, Colum Effect 4000 recommended blow-out height/projection height max 3.20 m , , ,74 15,98 5,24 4,40 25,80 38,80 51,60 64,60 5,05 2,55 5,57 3,41 1,00 1,70 2,40 2,70 6,50 9,00 13,00 14, E 4001,5 E 4002 E 4002,5 E application application application application 1,00 1,70 2,40 2,70 6,50 9,00 13,00 14, Colum Effect 5000 recommended blow-out height/projection height max 3.60 m , , ,30 8,40 12,70 5,40 32,10 48,40 69,30 91,90 3,41 3,37 7,06 8,47 2 x 1 1,70 2,50 3,40 4,00 9,00 13,50 18,50 21, E 5001,5 E 5002 E 5002,5 E application application application application 1,70 2,50 3,40 4,00 9,00 13,50 18,50 21, *measured in 3 metres distance Subject to technical alterations IN OUT F A A D MB M8 E F 10
15 Colum Effect 2000/3000/4000/5000 Product description This innovative air curtain installation with its compact, cylindrical shape has been specially developed for visible mounting, upright or hanging. Its preferred upright configuration offers the advantage of a heated air current of consistent velocity directly at floor level. Its pleasing design in conjunction with low-maintenance operation and invisible power connections (for upright versions) is a plus factor for architects, planners, building contractors and operators. The optionally galvanised RAL coloured powder coated covering or stainless steel version all blend in well with existing doors and doorways. Field of application This air curtain can be used at entrance and exit doors and revolving doors to prevent thermic mixing in summer and winter. Preferred application Standing upright right/left to doors or gates and at revolving doors to prevent the development of "cold spots"! Performance figures: When planning an installation for the Colum Effect 2000 model range, a blow-out or projection height of up to 2.5 m is indicated; for the Colum Effect 3000 range a height of up to 2.8 m; for the 4000 range up to 3.2 m and up to 3.6 m for the Colum Effect 5000 range. Detailed description A cylindrical self-supporting composite steel housing with two-part galvanised sheet steel cover with no visible screwed or riveted joints. Powder coated to RAL colour or in stainless steel version. Fine inlet screen and reusable filter that can be removed without tools for easy cleaning. Outlet screen with aluminium vanes (teardrop profile), depending on model in double or multiple versions for infinitely adjustable rectified air stream. Ceiling fixing via 8 mm captive bolts (e.g. with LSA ceiling mounting kit). Upright installation via tapped holes in the base plate and with recess for hidden power connections (for PWW / electrical). High-efficiency aluminium/copper heat exchangers (PWW) or finned tube heat exchangers (electrical) with easy to service, stable ribs and rib spacing. Double inlet, direct drive shock-mounted centrifugal fans, motor protected by thermal contact and electronic speed control. Fully assembled and wired. Delivery includes an electronic control Tronic D 5 for PWW, Tronic E for an electrical heater or Tronic M, all with a wide variety of adjustment options. Design versions One-sided installation, left or right. Suited to doorways of limited width. Two-sided installation. For extra-wide doors and doorways with high screening needs. Suspended installation. For use in door and doorway heights of 2.0 m (COLUMN 2000) up to 3.6 m (COLUMN 5000) in areas of limited side space. 11
16 > Wing Effect Air curtains for revolving doors with Jetflow technology
17 Technical Data > Wing Effect Model Length of unit mm Air volume m3/h Heat output at PWW 80/60 C kw** Water volume resistance kpa Heat output at PWW 60/40 C kw** Water volume resistance kpa Water connections female thread Output of electric heating at 400V kw Electric connections, fans, rated output Volt 50Hz kw A Sound level min/max db(a)* Weight kg Wing Effect 2002 Recommended blowout height max m 2002,2 2002, ,2 2,5 3, ,70 22,60 27,60 3,60 10,00 4,80 13,30 20,80 24,10 7,90 7,80 5,80 3/4 3/4 1 4/8/12 0,890 1,080 1,350 3,54 4,72 5, * Measured in 3 metres distance Subject to technical alterations > Wing Effect Product Description Special Jetflow nozzle continuously adjustable exhaust angle and exhaust opening. Composed of a self-supporting sheet steel housing and no screws visible in sight area. Available in every RAL colour or Stainless steel. Fine inlet screen and reusable filter that can be removed without tools for easy cleaning. Special Jetflow blow-out nozzle. A Upright installation via tapped holes in the base plate and with recess for hidden power connections (for PWW/electrical). High-effiiency Cu/Al heat exchangers (PWW) or finned tube heat exchangers (electrical) with easy to service, stable ribs and rib spacing. A A Double inlet, direct drive shock-mounted centrifugal fans, motor protected by thermal contact and electronic speed control. Fully assembled and wired Jetflow nozzle R 1100 suction grille with filter suction grille with filter R 1100 Jetflow nozzle 137 fixing d= 10 mm R el. connector in out out in 240 el. connector fixing d= 10 mm R revision top cover 650 revision top cover installation right installation left 13
18 > Nouveauline Designer air curtain with optimised new Jetflow Nozzle and EMC fans
19 Technical Data > Nouveauline Model Length of unit mm Air quantity m 3 /h Heat output at PWW 80/60 C kw Water volume resistance kpa Heat output at PWW 60/40 C kw Water pipe resistance kpa Water connections female thread Output of electric heating at 400V kw Electric connections, fans, Volt 50Hz kw A Sound level min/max db(a)* Weight kg Nouveauline S Recommended blowout height max m S 1 S 1,5 S 2 S ,50 11,30 15,10 18,80 7,20 3,40 8,00 3,00 6,50 10,00 14,10 18,70 2,50 10,70 4,30 7,30 0,26 0,39 0,52 0,65 1,20 1,80 2,40 3,00 40/53 40/54 40/55 40/ Nouveauline M Recommended blowout height max m M 1 M 1,5 M 2 M 2, ,30 15,70 22,60 27,60 5,20 3,60 10,00 4,80 9,70 13,30 20,80 24,10 6,30 7,90 7,80 5,80 0,29 0,44 0,59 0,74 1,40 2,10 2,80 3,50 40/54 40/55 40/56 40/ Nouveauline L Recommended blowout height max m L 1 L 1,5 L 2 L 2, ,50 22,60 33,50 39,60 2,27 7,30 5,50 7,50 10,80 18,10 26,10 32,60 7,80 14,40 12,20 10,30 0,44 0,59 0,74 1,03 2,10 2,80 3,50 4,90 40/55 40/56 40/57 40/ * Measured in 3 metres distance Subject to technical alterations ** LSA air curtains are delivered for heat exchangers PWW 80/60 C or 60/40º C and an intake air temperature of +20 C. It is not necessary for the air curtain to heat the boiler up to 80 C or 90 C for lower temperatures (PWW 60/40 C). The LSA air curtain also works excellently in the early or late season. Installing a thermostat limits the blowout temperature and thus adjusts the needed amount of energy to the amount of air. Jetflow nozzle energy saving up to 40% continuously and perfectly adjustable low noise development 15
20 Nouveauline S/M/L > Nouveauline length dimensions mm mm mm Vibration-free bedded EMC radial fans, separately powered, with motor overload protection unit. Threaded hole M 8 for ceiling mounting. > Nouveauline The electronic 5-level standard control panel Tronic EC with serially fitted manual/auto function, summer/winter function and contacts for additional external signallers. It is possible to shunt up to 12 devices. The electronic standard control panel Tronic E form electrical heating features a contact for connection a room thermostat to it. 5 fan speeds output, 3-level heater performance. Multiple control is not possible mm Measured without side covers. > Nouveauline height 333 mm Both panels feature a potential free contact (for external release), which can be connected to any GLT or DDC. Included in delivery is a 20 m shielded data cable with integrally moulded plug (other lengths are available upon request). For energy saving reasons, a thermostatic 2-way or 3-way valve can be ordered as a reasonable accessoire to keep the intake air temperature on an even level. It is delivered as loose enclosure and can be fitted easily by the customer. > Nouveauline description Others than the given lengths are possible. LSA air curtain with short deliverytime. Nouveauline designer air curtain is built with self supporting sheet steel, with concealed fixing knock on corners for an elegant looking finish. The standard modern colour is a white aluminium (RAL 9006), other RAL colours are available on request. Access door for maintenance opens together with the intake grille downwards. Outlet grille with 5 steps adjustable aluminium vane (anodized) for optimal air distribution. Inlet grilles made of 3D perforated plate for filterless and easy to maintain operation. Vibrationfree bedded centrifugal fans with external thermostat relays for motor protection. Threaded hole M8 for ceiling mounting. Jetflow nozzle multiple adjustable, for a low noise development - better protection of the air flow in certain situations, continuously adjustable exhaust angle and exhaust opening. EMC fans with interior speed controller - without condenser and without transformer. 85% degree of efficiency (20% better than conventional vans). In consequence of using EMC technology the operating costs will be reduced. > Nouveauline standard available colour: RAL 9006 (White Aluminium) Other RAL colours available on request 16
21 > Rondell Air curtains for revolving and circular sliding doors
22 Technical Data > Rondell Model Length of unit Air quantity Heat output at PWW 60/40 C Water connections Output of electric heating at 400V Electric connections, fans, rated output Sound level min/max Weight mm m 3 /h kw** female thread 400 V/kW Volt 50Hz kw A db(a)* kg /6/9 3/6/9 3/6/9 4/8/12 4/8/ /52 40/52 40/53 40/53 40/ /20/30 10/20/ /55 40/57 40/57 40/59 40/ /20/30 10/20/30 10/20/ /59 40/60 40/ * Measured in 3 metres distance Subject to technical alterations Dimensioning > Rondell Dimensioning > Rondell DT Type of mounting: built-in (EB) on top (AB) front (VB) HA Air curtain For dimensioning the air volume Passage/blow-out height HT = mm HT Revolving door DB For dimensioning the revolving door unit, the following main measurements are required: Decisive for the unit s size Diameter of door unit DT = mm Passage width DB = mm Height of attic HA = mm DB Number of door wings FZ = Passage angular dimension = Speed of the door / min. dz = U/min Standard is 3 to 4 rev/min Dimensioning the heating device t A outside temperature C (in relation to location) E.q. -2 C for Belfast but -1 C for Dublin Existing heating medium PWW (pump hot water) = C Electrical energy = V Unit will not be put into production until we have received drawings from revolving door manufacturer. 18
23 Rondell > Rondell Types of Mounting Air curtain installed on a revolving door (type AB ) D T D T D D A A A A D A D A D I A - A HB 100 A - A HB 100 DZ 50 D Air curtain installed in the revolving door (type EB ) 160 DT 40 DZ 50 D 240 E HA E > Rondell Function The air curtain blows warm air downwards to the front of the opening of the revolving door. This warm air stream is heating the inside air down to the bottom and shields it from cold outside air. The duct with the aluminium blow-out vanes matches the door radius. > Rondell Technical Description Revolving doors and air curtains seem to be contradictory but in practice this proofs to be an excellent combination. The use of a revolving door inside a building prevents draught. With no direct connection between inside and outside air, optimal inside climatic conditions are achieved. When the door revolves, cold air is entrained with the door wing and the difference in temperature between outside and inside air results in a cold zone directly behind the door. For heating the incoming air, an air curtain is to be installed directly behind or inside the revolving door which leads to pleasurable climatic conditions in the entrance area. By using a temperature control, both an optimum result and low energy consumption is achieved. A A Air curtain installed outside the revolving door (type VB ) A D A - A 240 D 50 A (mm) = length D (mm) = depth E (mm) = height A-50 (mm) = width of blow-out duct DT (mm) = diameter revolving door DA (mm) = outer diameter of blow-out duct DI (mm) = inner diameter of blow-out duct DZ (mm) = length of blow-out duct HA (mm) = height of the attic HB (mm) = height of faceplate D A DT 19
24 > Indu Effect Industrial Air Curtains
25 Technical Data > Indu Effect Type Air volume m 3 /h Heating capacity water 60 /40 kw ** Water resistance 60 /40 Pa Water connections 60 /40 female thread Electric fan supply Nominal capacity Volt kw A Sound pressure db(a)* Weight kg Indu Effect with heating 1200 P 1800 P 2400 P 3000 P x 1 1 /4 2 x 1 1 / Indu Effect without heating 1200 K 1800 K 2400 K 3000 K * Measured at a distance of 3 metres echnical changes reserved Installation possibilities > Indu Effect Connecting data per fan > Indu Effect 400 V/50 Hz - 0,8 Amp - 0,3 kw. U V 1 2 W 3 TK 5 TK 6 PE U V W TK U V W U V W TK TK M 3 PE M 3 PE M 3 PE TK TK TK 5-position speed controller 21
26 Indu Effect 120 > Indu Effect dimensioned sketch Vertical / horizontal design onder/zijaanzicht Front/rear view Outlet A Aspiration Renvoi vloerconsoles > Indu Effect LSA Industry Air Curtains are composed of self-supporting steel plate housings covered with synthetic foil, finished in RAL Other RAL colours are available on request. > Indu Effect is suitable to mount vertically or horizontally. > Indu Effect is equipped with axial flow fans IP 54, motor security through thermo contacts. > Indu Effect is equipped with a heat exchanger produced with a copper box with pressed aluminium lamellas > Indu Effect has a specially designed outlet grille with adjustable lamellas. 80 Outlet View from above/side-view A/2 17,5 Aspiration Soufflerie () M 10 nuts for suspension
27 > Controllers Plug & Play Our aspiration is that the installer never has to open the box
28 Wiring Diagrams OPTIONAL DIGITAL ROOM THERMOSTAT Operating switch to be installed by third parties Optional external on/off (e.g. BCS) contact open = release OPTIONAL! EXTERNAL ON/OFF (e.g. BCS) contact open = release OPTIONAL ROOM THERMOSTAT (potential free) (if applied remove bridging wire between 4-5) Optional magnetic valve V/50Hz Control print Input cable/plug Control print input cable/plug Control print input cable/plug Air curtain 1 Possible air curtain 2 and next (max. 11) Air curtain 1 Position 2 Position 1 type Tronic P type Tronic E Position 3 = Position 1 + Position 2 > 5-step controller for warm water version Max. 12 air curtains on one controller > 5-step controller for electric version Standard controller. Parallel connecting of more air curtains to one controller is not possible! Tronic P dimensions 100x70x28 mm Tronic E dimensions 145x90x45 mm Connecting cable between controller and air curtain Thermostatic three-way valve Room thermostat Door contact 24
29 Correction Factors > Energy Saving Versatile advocate the use of low water temperature for energy saving. Our standard outputs are based on flow and return of 60/40. ** LSA air curtains are supplied for a warm water supply with a temperature of 60 C and a return temperature of 40 C, inlet temperature +20 C. It is not necessary to supply the air curtain with other heat exchangers. See conversion table for other water temperature supplies and example below. T a Water C 100/80 90/70 80/60 70/50 60/40 55/35 T a air +15 C +18 C +20 C > Example The Effect M 2000 P60/40 gives 20.8kW with an air inlet temperature of 20 o C. If the system gives water temperatures of 90 o /70 o C then the factor is The capacity will become 2.17x20.8 = 45.14kW. 25
30
31 Design: artefact.ie Energy Efficient Door Curtains Dealer Stamp For technical details or details of your nearest stockist, please contact Versatile Ltd on or us on
The green and friendly entrance. Comfort air curtains Model CA 2
The green and friendly entrance Comfort air curtains Model CA 2 Energy saving and userfriendly air curtain Model CA 2 is the newest addition to the series Biddle comfort air curtains. It is Biddle s conviction
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationWOLF WARM AIR CURTAIN
TECHNICAL DOCUMENTATION WOLF WARM AIR CURTAIN TL-2 30m 3 /h TL-2 WARM AIR CURTAIN Additional silencer mat in the discharge section Attractive intake grille with rectangular perforations, self-centring
More informationEasily maintained air curtain. Comfort air curtains Model DoorFlow
Easily maintained air curtain Comfort air curtains Model DoorFlow Comfort air curtains Comfortable and inviting Outside doors of shops and public buildings are often left open for commercial reasons. n
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationThermozone AC 300/WAC 300
Ambient, no heat Electrical heat 8- kw Hot water heat Lengths: and.7 metres Thermozone AC 00/WAC 00 AIR CURTAINS FOR DOORWAYS BETWEEN.5 AND.5 METRES The Thermozone 00-series consists of the AC variant
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationDX AIR CURTAIN. SensAir
DX AIR CURTAIN SensAir Biddle and Daikin Complete climate system Since 2006 Biddle and Daikin have joined forces to provide a complete climate system for shops and public buildings. By combining Biddle
More informationDOORS P -SERIES. Shop & Business MADE OFAIR. The smart way for Shop & Business TEDDINGTON AIR CURTAIN SYSTEMS FILTERLESS OPERATION
FILTERLESS OPERATION P -SERIES The smart way for Shop & Business Equipped with the CORRIGO air discharge system Shop & Business DOORS MADE OFAIR The smart way of saving energy. Expensive, heated air often
More informationOptimal work climate with open doors. Industrial air curtains Model IndAC
Optimal work climate with open doors Industrial air curtains Model IndAC Industrial air curtain Optimal work climate During loading and unloading the door remains open, without the indoor climate being
More informationCHILLED ROOM AIR CURTAIN. IsolAir
CHILLED ROOM AIR CURTAIN IsolAir IsolAir chilled room air curtain Climate separation without heating Optimal climate separation The Biddle IsolAir chilled room air curtain is the perfect solution for internal
More informationRecessed. Air Curtain. Fig 1. Recessed air curtain
the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable
More informationOriginal instructions AR
Original instructions SE... 8 GB... 22 NO... 27 FR... DE... 6 ES... 4 NL... 46 IT... 5 RU... 56 Dimensions and connections AR20/AR25 M8 002/52 940/450 494 449 92 20 98 042/552 42 20 AR20/25A/E 40 275 DN5
More informationCHILLED BEAM CASSETTE IQ STAR LYRA
CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled
More informationCassette units Model Comfort Circle. - heating - cooling - ventilation
Cassette units Model Comfort Circle - heating - cooling - ventilation Cassette unit: Comfort Circle A comfortable room and climate are pleasant to work in and may also entice visitors to lengthen their
More informationCOMFORT AIR CURTAIN. DoorFlow
COMFORT AIR CURTAIN DoorFlow DoorFlow comfort air curtain Maintenance-friendly air curtain Energy-efficient and comfortable Outside doors of shops and public buildings are often left open for commercial
More informationComfortline L Series The appreciated, flexible Design Air curtain for mounting up to 4 metres
Ambient on request Water heated (WL / WH) Electrically heated (E) Colour customization Lengths,.5, 2, 2.5 and 3 metres ISO 900 Comfortline L Series The appreciated, flexible Design Air curtain for mounting
More informationTechnical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC
Technical Concept Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan Product Description The Plenum Integrated Filter Fan (PIFF) is a fan filter unit with integrated
More informationType CODE Speed Heating Cooling
CLIMA CANAL HYBRID - Low Temperature radiator - Heating and cooling - Build-in height of 10 > 14.5 cm CLIMA CANAL - Low Temperature radiator - Heating - Build-in height of 8.5 > 13 cm 24V EC MOTOR High
More informationCHH - Active Chilled Beam. Halton CHH. Active Chilled Beam
Halton CHH Active Chilled Beam Combined cooling, heating, and supply air unit for suspended ceiling / bulkhead installation Excellent suitability for hotel guest rooms with high requirements for thermal
More informationHalton Rex 600 Basic R6B - Active chilled beam
Halton Rex 600 Basic R6B - Active chilled beam Halton Rex 600 Basic chilled beam is: A base version to the combined cooling, heating, and supply air unit for flush installation within a suspended ceiling.
More informationHigh temperature air-to-water heat pumps
Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationSPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw
SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:
More informationThe swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.
Halton CSW Swirl comfort unit for ceiling installation The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply. A combined cooling, heating, and supply-air unit for flush
More informationAC25. Art.nr:
GB Installation and maintenance instruction for air curtains IMPORTANT: Read these instructions before the product is installed and used. Save the instructions for future use...2 Art.nr: 172785-01 Assembly
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationUnits for suspended ceilings
X X testregistrierung Units for suspended ceilings Type, hinged induced air grille, water connections Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings
More informationCOLD STORE AIR CURTAIN MAT
COLD STORE AIR CURTAIN MAT MAT cold store air curtain Optimal climate solution for cold stores The Biddle MAT air curtain is used for climate separation between the cold store and the loading area in order
More informationwww.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationCONDOR. Supply air ceiling QUICK FACTS
Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant
Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL
More informationTTL Products Exclusiv. TTL-TWISTO Design air curtain systems with energy saving effect and with EC-fan technology
TTL Products Exclusiv TTL-TWISTO Design air curtain systems with energy saving effect and with EC-fan technology TTL-TWISTO Door air curtain - against cold and draft with proven technology TTL-TWISTO the
More informationTechnology for life. Unit heater LH
Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables
More informationATC Heating Devices. P. 1 ATC Heating Devices
ATC Heating Devices P. 1 ATC Heating Devices ATC Heating Devices Suspended water heater FWW The hot water heater is attached to a wall using brackets. The direction of air flow (upwards or downwards) is
More informationPassive chilled beams
X X testregistrierung Passive chilled beams Type with frame, with perforated metal facing without perforated metal facing, RAL 9005, black Passive chilled beam in nominal lengths of up to 3000 mm and with
More informationNEW RANGE OF WARM AIR CURTAINS
NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible
More informationGalletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better
www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better A guide to choosing The group It s 1961 and Galletti with its Jolly copper
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationUnits for suspended cei lings
. X X testregistrierung Units for suspended cei lings Type, hinged induced air grille, water connections Chilled Beams No. 09.2.432 Eurovent certification HYGIENISCH GETESTET V DI 6022 Tested to VDI 6022
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationAIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating
Air curtains Air curtains The air curtains from VEAB create an effective, separating air trap between two temperature zones, for the entrances of department stores, public spaces, offices, etc. During
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationThermozone ADR 200/300 E/W
R Thermozone ADR 200/300 E/W Electrical heat 9-18 kw Water heat Lengths: 1, 1,5 and 2 metres Thermozone ADR 200/300 E/W Recessed air curtains for doors heights up to 3,5 metres ADR is our air curtain for
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationPolaris-I-60. active chilled beam. the future of space conditioning
the future of space conditioning Polaris-I-60 active chilled beam Function Cooling and supply air with two-way air distribution Available with heating and integrated controls Application Offices, hotels,
More informationHeating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air
Heating and cooling ceiling systems Suspended ceiling systems Heating Cooling Fresh Air Clean Air The complete heating and cooling ceiling systems Customers can now order a fully suspended heating and
More informationTEDDINGTON AIR CURTAIN SYSTEMS L -SERIES. The smart entrance for Shop & Business. Equipped with the CORRIGO air discharge system
L -SERIES The smart entrance for Shop & Business Equipped with the CORRIGO air discharge system Doors Made ofair The smart energy-saving entrance. An air curtain system which balances moderate output with
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
Electrically heated 3000 6000 W 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationDomestic & Commercial Fans
Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO
More informationTEDDINGTON AIR CURTAIN SYSTEMS. Air curtain technology for industrial premises and warehouses DOORS MADE OFAIR. Industries
Air curtain technology for industrial premises and warehouses Industries DOORS MADE OFAIR Air doors. Doors and hall entrances are opened frequently at industrial premises and warehouses. An exchange takes
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationBTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa
FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation BTBa CEILING UNIT FLUSHLINE BTBa FLUSHLINE BTBa is a complete climate system offering immense flexibility. Ideal for large areas with
More informationProduct Catalogue Edition 2007
Product Catalogue Edition 2007 { Creating the perfect environment About Thermo Air A drilling platform owner requires cooling for his processes without the danger of explosion. A store owner would like
More informationEnergy-efficient heat source provides comfort in large rooms
AIR HEATER NOZ NOZ air heater Energy-efficient heat source provides comfort in large rooms When it comes to providing large, and often high buildings, with the best possible source of efficient heating
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationThermozone AD Corinte
R Thermozone AD Corinte Ambient, no heat Electrical heat 15 22,5 kw Water heat Vertical: 2,2 and 2,5 metres Horizontal: 1,7 and 2,2 metres Thermozone AD Corinte Air curtains for doors with heights of up
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationTOSHIBA AIR CONDITIONING
Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD
More informationNEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationAI R CU RTAI N SYSTEMS. The green Solution for Shop & Business
E - S E R I E S The green Solution for Shop & Business Trendsetting energy efficiency. Expensive, heated air escapes through open doors. This is unpleasant and wastes a great deal of energy. Teddington
More informationAir Curtains. For a better working environment. Tel:
Air Curtains For a better working environment www.sill-line.com Tel: 01327 301922 Email: sales@sill-line.com www.sill-line.com Standard s This elegant slimline range of powerful modular air curtains, built
More informationBRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING
Low Water-Temperature system wall and ceiling mounting 2-or 4-Pipe system heating and /or cooling with or without casing easy installation EC motor silent, powerful, economical, sustainable 2-PIPE 4-PIPE
More informationNEW GREEN TECHNOLOGY
NEW GREEN TECHNOLOGY - suitable for all heating systems Magnetic Boiler installed in all fan coils - no need for external devices! A c t i v e G r e e n S w e d e n A B ACTI VE Operation limits This technology
More informationACCESSORIES ITEM NUMBER. Digital timer, burning and ventilating. RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. fault detector.
ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5
More informationContact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.
Contact, Overview, Index Ceiling Heating/Chilled Plexus Professor Pilot Architect Polaris I & S Plafond Podium Celo Cabinett Capella Fasadium Atrium H & C /Loggia Regula Drypac TM Lighting TEKNOsim 0 0.00
More informationCentrifugal air heaters hot water or electrical supply
The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:
More informationCBC - Active Chilled Beam. Halton CBC. Active Chilled Beam
Halton CBC Active Chilled Beam Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited for spaces with high cooling loads and low humidity load Ideal
More informationHalton CHB Active chilled beam with boost function for bulkhead installation
Halton CHB Active chilled beam with boost function for bulkhead installation Combined cooling, heating, and supply-air unit for bulkhead installation Different sizes, to meet various cooling and air-flow
More informationFan Coil Range HYDRONIC TERMINALS
Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationCEILING SPEAKER SYSTEM
INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-2852C TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 4 5. INSTALLATION... 5 7. REPAINTING
More informationCOR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics
AIR CURTAINS COR Series Designed for wall application in commercial and industrial environments. COR Can be fitted up to a height of 2,5 metres. performance tangential propeller/impeller giving a low sound
More informationCWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT
TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationAir cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw
Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with
More informationAxial fans The right fan for every house
Axial fans The right fan for every house Axial fans with frame for incorporation into walls Big Dutchman offers a wide range of axial fan types. This variety allows us to meet all the climate requirements
More informationQTS SELECTION TECHNICAL BOOKLET
EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationLDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More informationVENTILATED CEILINGS PLENUM SPANTILE COMBINED ADVANTAGES
VENTILATED CEILINGS PLENUM SPANTILE COMBINED We reserve the right to change specification in this brochure without prior notice. August 07 ADVANTAGES Flexible layout in catering equipment Addition of equipment
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Plenum box with damper blade and square diffuser face Horizontal swirling air discharge For comfort zones, with fixed air control blades Circular and
More informationLSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES
Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures
More informationThermozone RD. Air curtains for revolving doors
Electrical heat 6-36 kw Water heat Thermozone RD Air curtains for revolving doors Thermozone RD is an ideal solution for any environment with revolving doors. The air curtain is mounted on top of the door
More informationHalton Rex for Vario R6O - Variable air volume chilled beam
Halton Rex for Vario R6O - Variable air volume chilled beam Halton Rex for Vario chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling Well suited
More informationElztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications
Single panel radiant heater for offices, shops etc. 3 models 3 600 1500 W Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments
More informationT-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION Thermoscreens Ltd St. Mary s Road Nuneaton Warwickshire
More informationINTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold
RADIANT PANELS TRENCH PERIMETER GRILLES ELEMENTS PIPER FARM, BROMLEY GREEN ROAD, ASHFORD, KENT. TN26 2EF TEL: 01233 733308 FAX: 01233 733883 E-MAIL: sales@feukltd.com RADIANT PANEL RANGE INTRODUCTION HOW
More informationGas heaters and convectors ROBUR
Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7
More information