1 TP970 Series CONVERTASTAT Kits APPLICATION REPLACEMENT DATA Each CONVERTASTAT Kit includes a universal wall plate adapter, cover, and a TP970 Series Thermostat to replace various manufacturer s thermostats. The thermostat cover is universal, allowing horizontal or vertical mounting and provides windows with or without setpoint and thermostat displays. All components needed to create a cover to meet building requirements are included. GENERAL RC121 INSTALLATION This sheet gives procedures for removing each manufacturer s thermostat and installing the appropriate TP970 Series CONVERTASTAT Kit. When the old mounting plate is removed, retain the screws to use for mounting the adapter plate. Cut the existing tubes as close as possible to the thermostat. Do not remove the antikink springs from cut tubes. Do not allow tubes to slip inside the wall after removing the old thermostat. This sheet describes replacing existing Johnson, Powers, and Robertshaw thermostats with the TP970 Series CONVERTASTAT Kit ( CONVERTASTAT Kit ). The appropriate CONVERTASTAT Kit, selected from Table 1, replaces newer (small size) models of Johnson, Powers, or Robertshaw vertical or horizontal pneumatic thermostats used in two-pipe applications and mounted on hollow wall (drywall) construction with air connections made directly to the thermostat using 5/32 in. plastic tubing, without the use of a wall fitting. Copyright 1995 Honeywell Inc. All Rights Reserved

2 Table 1. TP970 Series CONVERTASTAT Kit Cross-Reference. Robertshaw* Order No. Description Johnson Powers Original Uni-line TP970A2145 Direct acting, single-temp, two - pipe, 60 to 90F range TP970A2242 Same as TP970A2145 except with beige plastic cover TP970A2234 TP970B2077 TP970B2166 TP970B2150 TP971A2102 TP971A2183 TP972A2192 TP972A2200 Same as TP970A2145 except with 15 to 30 C range Same as TP970A2145 except reverse acting Same as TP970B2077 except with beige plastic cover Same as TP970B2077 except with 15 to 30 C range Two-temp, two-pipe, 60 to 90F (16 to 32C) range, DAY and NITE setpoint knobs, psi (90/124 kpa) changeover, field adjustable to 16/21 psi (110/145 kpa) Same as TP971A2102 except with beige plastic cover Single-temp, two-pipe, proportioning, 60 to 90F (16 to 32C) range, RA Summer 13 psi (90 kpa) or 9 psi (62 kpa) unit vent, DA Winter 18 psi (124 kpa) changeover, field adjustable Same as TP972A2192 except RA Summer 19 psi (131 kpa), DA Winter 14 psi (97 kpa) changeover T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T * For 2 x 2 Thermostat mounted without 3 x 3 wall plate. Kit can be used only if two-pipe wall fitting installed originally. Use kit if DAY/NITE lever feature is acceptable. ** Original thermostat was part of a kitt. Use kit if Fahrenheit scale is acceptable. TH TH T T TH T T ** TH TH TH T T TH T T TH TH TH TH TH TH T T T T T T T ** ** ** ** ** TH T Installation requires the following tools: 1/16 in. Allen wrench in. Allen wrench Thermostat Tool CCT735A Side cutters (diagonals) or knife to cut tubes Phillips screwdriver Standard screwdriver 5/32 in. tubing plug (optional), CCT1814 (plastic) or CCT1815 (aluminum) Honeywell Thermostat Tool Kit CCT3863 includes thermostat Tool, thermostat key, and gage adapter

3 Remove Johnson Thermostat Remove Robertshaw Thermostat Loosen (counterclockwise) top and bottom screws to remove cover. Remove thermostat mounting screws at top and bottom and remove thermostat from mounting plate. Cut tubes near air head and temporarily plug main line to conserve air. Remove mounting plate and retain screws. Proceed to the Install New Thermostat section. Turn cover screw on bottom inward (clockwise) to remove cover. Remove mounting screws and remove thermostat from mounting plate. Do not remove mounting plate. Cut tubes near fitting and temporarily plug main line to conserve air. Proceed to the Install New Thermostat section ROBERTSHAW Fig. 1. Johnson Thermostat. Remove Powers Thermostat Loosen (counterclockwise) screws on each side to remove cover. Pull thermostat from the mounting plate. Cut tubes near connector and temporarily plug main line to conserve air. Remove old mounting plate and retain screws. Proceed to the Install New Thermostat section MCC POWERS C2314 Fig. 2. Powers Thermostat. C2313 Fig. 3. Robertshaw Thermostat. Install New Thermostat 70 C2315 Feed the tubes through the large hole in adapter plate (Fig. 4). Match holes of the adapter plate to the wall screw holes. Mount adapter plate using screws retained from removal of old mounting plate. Do not overtighten the screws. NOTE: If any wall screw holes coincide with the noncoded holes on the adapter plate (Fig. 4), proceed as follows (If not, continue with Step 3.): a. With adaptor plate away from the wall, ream out or strip the threaded holes by tightening the screws retained when removing the old mounting plate. Tighten with enough force so that the screws move freely. Remove and retain screws. If the wall screw holes are larger than #6, enlarge the adapter plate holes to allow enough clearance for the screws. b. After removing temporary plug, push tubes onto thermostat backplate (main tube has air blowing out and must be connected to the M barb connection on rear of backplate). c. To remove cover from thermostat, slowly drive the screws inwards (clockwise) until cover is free to remove. To remove thermostat from backplate, spread retaining clips (Fig. 5) and separate

4 NOTE: d. Align and attach the backplate and adapter plate to the mounting screw holes with screws retained from stripping the threads in adapter plate. e. Proceed to Step 6. When adapting to a Johnson thermostat, if the holes in the wall are out of alignment with the adapter plate holes, use any available hole for an additional wall anchor. AIR TUBING CONNECTIONS (3) UP B B SET SCREWS M RETAINING CLIPS PILOT HOLE FOR #6 SELF-TAPPING SCREW HOLES CODED PER MANUFACTURER (10) (EXAMPLE: J = JOHNSON) COVER MOUNTING EARS Fig. 5. Backplate. C182-1 TUBING NON-CODED HOLE (2) Fig. 4. Adapter Plate Installation. C2837 To remove cover from thermostat, drive the screws inwards (clockwise) until cover is free to remove. To remove thermostat from backplate, spread retaining clips (Fig. 4) and separate. After removing temporary plug, push tubes onto the thermostat backplate (mainline tube has air blowing out and must be connected to the M barb connection on rear of backplate). Attach backplate to adapter plate with thread-forming screws provided with the thermostat. Do not overtighten the screws. Press the thermostat onto the backplate until it is fully seated and the clips (Fig. 5) on the backplate have engaged. Remove shipping stops (Fig. 6). Mount cover (see the Thermostat Cover Mounting section). QUICK-MOUNT STAT SETSCREWS THROTTLING RANGE SETTING INDICATOR TEMPERATURE INDICATOR SETPOINT INDICATOR SHIPPING STOP (2) (REMOVE WHEN INSTALLING) Fig. 6. TP970 Series Thermostat with Cover Removed. Thermostat Cover Mounting CALIBRATION SCREW SETPOINT ADJUSTMENT SETPOINT LOCK SCREW STOPS-TEMPERATURE SETTING C7257 Remove caution card from cover. Select the correct window (vertical or horizontal/ single, dual, or blank). Peel the release liner from window back (Fig. 7). Be careful that the window is oriented correctly for the installation. When viewed from the front of the cover, the setpoint and Day/Auto openings are on the bottom for a vertical thermostat or on the right for a horizontal thermostat. The cover has slots which must mate with the mounting ears on the backplate (Fig. 5)

5 CAUTION Before installing window, remove card. Check window selection and orientation to cover. The setpoint, Day/ Auto openings and/or inserts must be down or to the right. Once assembled, disassembly may damage the window. Mount the cover. Hook the two slots on the cover bottom (right end for horizontal mounting) to the ears on the backplate. Swing the cover into place and back out (counterclockwise) the setscrews with a thermostat tool or a inch Allen wrench to secure SETSREW HOLES (4) (USE HOLES CLOSEST TO THE WALL) WINDOW (DUAL SHOWN, PARTIALLY INSTALLED) Throttling Range Thermostat throttling range (TR) is factory set at 4 degrees F (2.2 degrees C) and should not require any change under normal operating conditions. If a change in throttling range is necessary, use the following procedures to reset the throttling range to the values specified on the job drawings. Recalibration is required if throttling range is changed. Remove cover and install 0 to 30 psi (0 to 210 kpa) gage (with gage adapter) in gage tap (Fig. 8). Slide the throttling range adjustment to the desired position on the throttling range scale. Mechanically check the TR by moving setpoint adjustment until the branch line pressure is 3 psi (21 kpa); note the setpoint indicator setting. Move the setpoint adjustment until the branch line pressure is 13 psi (90 kpa) and note the setpoint indicator setting. The difference in setpoint indicator settings is the actual throttling range. NOTE: The ambient temperature ±1/2 degree of the throttling range must not exceed the minimum or maximum setpoints of the thermostat. That is, with a throttling range of 6 degrees F (3.3 degrees C) and an ambient temperature of 62F (16C), this procedure will not work for a TP970A which has a minimum setpoint of 60F (15C). Recalibrate using procedures in the Recalibration section. C7256 Fig. 7. Assembly of Cover with Window Frame and Insert. CHECKOUT AND TESTING Equipment Required The following equipment is available from your Serviceline Supplier: Gage or , 0 to 30 psi (0-210 kpa) CCT729 Gage Adapter CCT735A Thermostat Tool NOTE: Before making adjustments, set the thermostat to the desired setpoint and let the system operate long enough to stabilize. Make certain that the system is stable before checking calibration. All thermostats are accurately factory calibrated and should require only a calibration check to ensure correct operation

6 THROTTLING RANGE SCALE (DAY/SUMMER) GAGE TAP THROTTLING PLATE (2) THERMOMETER CALIBRATION BOBBIN MAX MAX THROTTLING RANGE ADJUSTMENT (NITE/WINTER) SCALEPLATE SETPOINT INDICATOR TEMPERATURE INDICATOR CALIBRATION SCREW (DAY/SUMMER) SETPOINT INDICATOR (NITE/WINTER) SETPOINT LOCK SCREW DAY/AUTO LEVER (TP971 ONLY) SETPOINT DIAL (NITE/WINTER) CALIBRATION SCREW (NITE/WINTER) SETPOINT LIMIT STOPS SETPOINT ADJUSTMENT NOTE: NOT ALL ADJUSTMENTS ARE ON ALL THERMOSTATS. C5410 Fig. 8. TP971 and TP972 Controls and Indicators, Front View with Cover Removed. Setpoint Limit Adjustment To set minimum or maximum setpoint limits: Loosen the setpoint lockscrew (Fig. 8). Move each stop to the desired position. Tighten the setpoint lockscrew. Check the positioning of the stops by changing the setpoint. Changeover TP971 and TP972 thermostats have changeover features. The TP971 has day/night changeover and the TP972 has summer/winter changeover. TP971 controls direct acting at day setting with 13 psi (90 kpa) main air pressure and direct acting at the lower night setting with 18 psi (124 kpa) main air pressure. The TP972 controls reverse acting (RA) for summer cooling at 13 psi (90 kpa) main air pressure and direct acting (DA) for winter heating at 18 psi (124 kpa) main air pressure. Remove thermostat from backplate if mounted. Remove the changeover adjustment screw (Fig. 9) on back of thermostat. Replace the gold-colored spring with the silvercolored spring furnished in the TP971 kit. Order Spring for TP972 conversion. Reinstall the changeover adjustment screw and set flush with the top of the spring chamber. Mount thermostat on backplate again. Follow procedures in the Changeover Calibration Check section and recalibrate if necessary. The branchline pressure (BLP) drops as the temperature drops when the thermostat is operating DA. The BLP drops as the temperature rises when the thermostat is operating RA. FILTER COVER MOUNTNG SCREWS (4) M B Changeover Conversion On some systems the lower main air pressure is higher (14 or 15 psi [97 or 103 kpa]) so the changeover point must be raised. On these systems turn the changeover adjustment screw (Fig. 9) one-half turn clockwise for each 1 psi (7 kpa) over 13 psi (90 kpa). THERMOSTAT MULTISTAGE FILTER CHANGEOVER ADJUSTMENT SCREW SPRING CHAMBER P TP971s or TP972s used on systems having 16/21 psi (110/ 145 kpa) or 13/16/21 psi (90/110/145 kpa) main air pressure require a different spring for proper changeover operation. Change the spring as follows: DAY/AUTO LEVER (TP971 ONLY) Fig. 9. TP970 Series Thermostat Back View. C

7 Changeover Calibration Check Set main air pressure to the higher pressure setting (night for TP971, winter for TP972A2192, and summer for TP972A2200). Insert gage using gage adapter into the gage tap (Fig. 8). If the results in Steps 3 or 5 are not correct, go to the Changeover Calibration section. TP971: Turn day setpoint adjustment until the setpoint indicator reads approximately 10F (5.5C) degrees above the space temperature and set the night setpoint dial below space temperature. The gage should indicate main air pressure. Push the day/auto lever to the day (left) position; it should stay there and the BLP should go to 0 psi (0 kpa). TP972: Turn the setpoint adjustment until the setpoint indicator reads approximately 10F (5.5C) degrees above space temperature. BLP should go to 0 psi (0 kpa). Set main air pressure to lower pressure setting (day for TP971, summer for TP972A2192, and winter for TP972A2200). Use 16 psi (110 kpa) on 13/16/21 psi (90/110/145 kpa) systems. TP971: With day setpoint indicator and night setpoint dial set as in Step 3, BLP should go to zero. Push the day/ auto lever to the day (left) position, it should return to the auto position when released. TP972: With the setpoint indicator set as in Step 3, BLP should go to main air pressure. Changeover Calibration Remove thermostat from the wall. Loosen screws. Remove backplate from wall but do not disconnect tubes from backplate. Plug thermostat into backplate. Use following changeover procedures for calibration with or without a branch line pressure gage. With Branchline Pressure Gage If the thermostat changeover point was not correct at Step 3 of the Changeover Calibration Check procedure, use the screwdriver end of the thermostat tool to turn the changeover adjustment screw (Fig. 10) one-quarter turn counterclockwise. Make a calibration check. Continue with one-quarter turn adjustments followed by a calibration check until the changeover point is correct. If the thermostat changeover point was not correct at Step 5 of the Changeover Calibration Check procedure, use the TP970 Series thermostat tool to turn the changeover adjustment screw (Fig. 10) one-quarter turn clockwise. Make a calibration check. Continue with one-quarter turn adjustments followed by a calibration check until the changeover point is correct. Fig. 10. Location of Calibration Adjustment Screw with Backplate Attached. Without Branchline Pressure Gage (TP971 Only) CHANGEOVER ADJUSTMENT SCREW Set system pressure to 18 psi (124 kpa) (night pressure). Hold the day/auto lever in the day (left) position. Turn the changeover adjustment screw counterclockwise until the lever holds in place. Release the lever and slowly turn the changeover adjustment screw clockwise until the lever snaps back to the auto position. Turn the changeover adjustment screw an additional one-eighth to one-quarter turn clockwise. This places the changeover in calibration and allows for normal main air pressure fluctuations. Calibration Check Direct-Acting, Bimetal Elements Turn setpoint adjustment until the setpoint indicator reads 5 degrees F (2.8 degrees C) below actual space temperature as measured by a test thermometer and allow thermostat to build up branch line pressure. Turn setpoint adjustment (Fig. 8) up slowly. If thermostat begins to bleed off between 1 and 3 degrees F (0.5 and 1.5 degrees C) below space temperature, no recalibration is necessary. Reverse-Acting, Bimetal Elements C183-2 Turn setpoint adjustment until the setpoint indicator reads 5 degrees F (2.8 degrees C) above actual space temperature as measured by a test thermometer and allow thermostat to build up branch line pressure. Turn setpoint adjustment (Fig. 8) down slowly. If thermostat begins to bleed off between 1 and 3 degrees F (0.5 and 1.5 degrees C) above space temperature, no recalibration is necessary

8 Recalibration CAUTION The thermostat is very sensitive and should not be heated by excessive handling during calibration. NOTE: References in the following procedures to a 30 psi (210 kpa) gage mean the gage with gage adapter listed in Equipment Required section. TP972 day (left) calibration screw (Fig. 8) until the gage indicates 0 psi (0 kpa). Turn the calibration screw in the opposite direction until the gage indicates 8 ±1 psi (56 ±7 kpa). With 18 psi (126 kpa) night main air pressure, rotate the night setpoint dial until its setting agrees with the indicated temperature. Repeat Steps 3 and 4 using the night (right) calibration screw. The thermostat is now in calibration. Remove the gage and replace cover. TP970 TP971 Remove the cover and install a 30 psi (210 kpa) gage into the gage tap. Turn the setpoint adjustment until the setpoint indicator reads the space temperature. Turn the calibration screw (Fig. 5) until the gage indicates 0 psi (0 kpa). Turn the calibration screw in the opposite direction until the gage indicates 8 ±1 psi (56 ±7 kpa). The thermostat is now calibrated. Remove the gage and replace the cover. Remove the cover and install a 30 psi (210 kpa) gage into the gage tap. Turn the setpoint adjustment until the setpoint indicator reads the indicated temperature. With 13 psi (90 kpa) day main air pressure, turn the Remove the cover and install a 30 psi (210 kpa) gage into the gage tap. Turn the setpoint adjustment until the setpoint indicator reads the indicated temperature. With 13 psi (90 kpa) main air pressure, turn the left calibration screw (Fig. 8) until the gage indicates 0 psi (0 kpa). Turn the calibration screw in the opposite direction until the gage indicates 8 ±1 psi (56 ±7 kpa). With 18 psi (126 kpa) main air pressure, repeat Steps 3 and 4 using the right calibration screw. NOTE: If the thermostat has a second setpoint dial (Fig. 8), it must be set to the indicated temperature before returning to Steps 3 and 4. The thermostat is now in calibration. Remove the gage and replace the cover. Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis, MN Home and Building Control Honeywell Limited-Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 Helping You Control Your World Rev

TP970 and TP9600 Series Pneumatic Thermostats

TP970 and TP9600 Series Pneumatic Thermostats TP970 and TP9600 Series Pneumatic Thermostats GENERAL TP973A,B and TP9630A,B SERVICE DATA The TP970 and TP9600 Series Pneumatic Thermostats are one-, two-, or three-pipe, proportioning thermostats with

More information

TP970 and TP9600 Series Pneumatic Thermostats

TP970 and TP9600 Series Pneumatic Thermostats TP970 and TP9600 eries Pneumatic Thermostats ENGINEERING DATA Contents Introduction... 2 Fundamentals of Thermostat Operation... 2 General... 2 Flapper-Nozzle Operation... 2 Valve Unit Operation... 2 TP973A,

More information

HP970A, B and HP972B Pneumatic Humidistats

HP970A, B and HP972B Pneumatic Humidistats Honeywell HP970A, B and HP972B Pneumatic Humidistats SERVICE DATA MB HP970A, B HP972B VALVE SUPPLY N.C. C322.5 Fig. 1. Typical HP970A, 6 or HP972B Humidistat Two-Pipe Hookup. HP972B The HP97OA, B and HP972B

More information

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION

TP970 SERIES ASPIRATING WALL BOX ASSEMBLIES BEFORE INSTALLATION TP970 SERIES 14002424 ASPIRATING WALL ASSEMBLIES BEFORE INSTALLATION 1. The HP970 and TP970 Series Aspirating Wall Box Assembly (Fig. 1) is available in two versions: - 14002424-002 Aspirating Wall Box

More information

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase M3375 M3375 T890A/908AJ Heating or Cooling Thermostat/Wallplate; T890A/Q68B Heating/Cooling Thermostat/Subbase Installation Instructions for the Trained Service Technician. Preparation NOTE: Order Q68B

More information

TK-1001, 1101, 1201, 1301, 1601

TK-1001, 1101, 1201, 1301, 1601 TK-1001, 1101, 1201, 1301, 1601 Pneumatic Room Thermostats General Instructions DEVICE INFORMATION Identification Thermostats of this family may be easily identified by referring to the part number located

More information

TP970-72, TP970-74, TP9600, and TP9630 Pneumatic Sensors, Humidistats, and Thermostats INSTALLATION INSTRUCTIONS

TP970-72, TP970-74, TP9600, and TP9630 Pneumatic Sensors, Humidistats, and Thermostats INSTALLATION INSTRUCTIONS TP970-72, TP970-74, TP9600, and TP9630 Pneumatic Sensors, Humidistats, and Thermostats INSTALLATION INSTRUCTIONS Contents INTRODUCTION BEFORE INSTALLATION INSTALLATION CALIBRATION APPENDIX: S... 2... 2

More information

TK-1801, TK-1811 TK-1801, TKR-1811

TK-1801, TK-1811 TK-1801, TKR-1811 TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or

More information

HP970 and TP970 Series Standard Covers and Accessories

HP970 and TP970 Series Standard Covers and Accessories HP970 and TP970 Series Standard Covers and Accessories FEATURES SPECIFICATION DATA Compact cover design for aesthetic appearance Available with or without setpoint opening for tamper resistance Satin chrome,

More information

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers T4031A,B,P; T6031A,B Refrigeration Temperature Controllers FEATURES PRODUCT DATA Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

More information

T874 Multistage Thermostat and Q674 Subbase

T874 Multistage Thermostat and Q674 Subbase SUPER TRADELINE T874 Multistage Thermostat and Q674 Subbase Application The T874D Thermostat and Q674E Subbase provide 4 to 30 Vac control of standard stage heating and stage cooling systems. The Y594D

More information

Retrostat Kits for Johnson Controls D/N or H/C Thermostats

Retrostat Kits for Johnson Controls D/N or H/C Thermostats Document No. 129-141 Retrostat Kits for Johnson Controls D/N or H/C Thermostats Product Description The Retrostat Kits convert a Johnson Controls day/night or heating/cooling pneumatic thermostat to a

More information

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK

TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TK-2001, TK-2012, TK-2201, TK-3001, TK-3201, TK-4001, TK-4012, TK-4212 TK-4212-201 Pneumatic Bulb Thermostats General Instructions

More information

T834C Heating-Cooling Thermostat

T834C Heating-Cooling Thermostat M3375 M3375 TRADELINE T834C Heating-Cooling Thermostat Application T834C Thermostats control 4 to 30 Vac single-stage heating-cooling systems. See Table for specific models and applications. An spdt mercury

More information

T4398A,B Precision Electric Heating Thermostat

T4398A,B Precision Electric Heating Thermostat T398A,B Precision Electric Heating Thermostat FEATURES PRODUCT DATA APPLICATION The T398 Electric Heating Thermostat provides precise, accurate line voltage control of electric heating equipment. A snap

More information

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A Heating/Cooling Thermostat and Subbase Package T8196A/Q682A OWNER'S MANUAL M3375 Congratulations on your purchase of a Honeywell energy saving thermostat. The Honeywell name is your assurance of accurate

More information

T4098A,B Deluxe Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats T4098A,B Deluxe Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides 2 F

More information

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat Document No. 155-069P25 TH 193-5 Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat 50 60 70 80 TH0356R1 70 60 80 POWERS Description Features The TH 193 HC Hesitation Thermostats are

More information

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION TK-5001, 5101 TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Pneumatic Room Thermostats General Instructions GENERAL INFORMATION The pneumatic thermostats are used for proportional

More information

W43A Humidistat. Features and Benefits

W43A Humidistat. Features and Benefits Master Catalog 125 Humidity Controls Section W Product/Technical Bulletin W43A Issue Date 1095 W43A The W43A controls humidifying and/or dehumidifying equipment. Typical uses include the control of humidity

More information

Powers TM Controls TH 188 Unit Mounted Thermostat

Powers TM Controls TH 188 Unit Mounted Thermostat Powers TM Controls Technical Instructions Document No. 155-064P25 TH 188-2 Description The is a remote bulb, gradual acting pneumatic instrument which maintains a pre-selected temperature by positioning

More information

Home and Building Control Home and Building Control Helping You Control Your World

Home and Building Control Home and Building Control Helping You Control Your World M3375 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited/Honeywell Limitée 1985 Douglas Drive No. 740 Ellesmere Road Golden Valley, MN 55422

More information

T4398A,B High Performance Electric Heat Thermostats

T4398A,B High Performance Electric Heat Thermostats T498A,B High Performance Electric Heat Thermostats FEATURES PRODUCT DATA Controls both fan-forced and baseboard electric heaters. Temperature-responsive, vapor-filled dual diaphragm sensing element provides

More information

features Overview Powerstar Room Thermostats Description Applications Selection Guide Thermostats & Hygrostats A-3

features Overview Powerstar Room Thermostats   Description Applications Selection Guide Thermostats & Hygrostats A-3 Overview Proven to provide fast response and highly accurate temperature control, Powerstar Pneumatic Room Thermostats are designed to control heating and/or cooling by operating a variety of pneumatic

More information

CT1500, CT1501, CT1502, CT1503

CT1500, CT1501, CT1502, CT1503 Timer Thermostat Fuel Saver Heating-Only Thermostat and Wallplate or Heating/Cooling Thermostat and Subbase Models CT1500, CT1501, CT1502, CT1503 Heat Only CT1500 Heat/Cool CT1501 Central Electric Heat/Cool

More information

CT500 Electronic Thermostat

CT500 Electronic Thermostat CT500 Electronic Thermostat OWNER'S GUIDE MERCURY NOTICE If this control is replacing a control that contains mercury in a sealed tube, do not place your old control in the trash. Dispose of it properly.

More information

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell

T874A-F Multistage Thermostats; Q674A-G Subbases by Honeywell M3375 M3375 T874A-F Multistage Thermostats; Q674A- Subbases by Honeywell Installation Instructions for the Trained Service Technician Application The T874A-F Thermostats provide 4 to 30 Vac control for

More information

CORALAIS BODYSPA BATH AND SHOWER FAUCET

CORALAIS BODYSPA BATH AND SHOWER FAUCET CORALAIS BODYSPA BATH AND SHOWER FAUCET 1. BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

Q382A,B Pilot Burners

Q382A,B Pilot Burners Q382A,B Pilot Burners INSTALLATION INSTRUCTIONS APPLICATION The Q382A,B Pilot Burners provide main burner ignition for natural and LP gas-fired equipment. The design makes them ideal for use with any millivolt

More information

CT2700 An Electronic Round Programmable Thermostat

CT2700 An Electronic Round Programmable Thermostat CT2700 An Electronic Round Programmable Thermostat USER S GUIDE MERCURY SWITCH TYPICAL LOCATION OF A MERCURY SWITCH IN A THERMOSTAT M064 RECYCLING THERMOSTAT If this thermostat is replacing a control that

More information

MagicStat CT3300 Programmable Thermostat

MagicStat CT3300 Programmable Thermostat MagicStat CT3300 Programmable Thermostat Installation and Programming Instructions Weekday/Weekend (5-day/2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model

More information

T8411R Electronic Heat Pump Thermostat

T8411R Electronic Heat Pump Thermostat T84R Electronic Heat Pump Thermostat INSTALLATION INSTRUCTIONS The T84R Heat Pump Thermostat provides 24V control of two-stage heating and one-stage cooling heat pump system with manual changeover from

More information

Installation Instructions EFS Hand Washing Station

Installation Instructions EFS Hand Washing Station Installation Instructions EFS Hand Washing Station Both water and soap are sequenced and dispensed from outlet. Override button allows for non potable, water-only dispensing. Lighted icons indicate the

More information

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards FEATURES PRODUCT DATA TG509 TG511D TG510A TG512B Available in four sizes: mini, small, medium and large, to fit virtually all thermostats.

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

GAS OVEN SERVICE MANUAL

GAS OVEN SERVICE MANUAL GAS OVEN SERVICE MANUAL MODELS: MB42, MB60, MB236, MB260, MB866, SD236, SD248, SD260, SD448, SD660, SD1048, SD1060, SD866, SD10866, WF42, WF60 2018 Marsal 42 Allen Martin Drive, Essex Junction, VT 05452

More information

The T6140A,B Remote Bulb Temperature Controller

The T6140A,B Remote Bulb Temperature Controller T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold

More information

T7100D Microelectronic Conventional Thermostat

T7100D Microelectronic Conventional Thermostat T7100D Microelectronic Conventional Thermostat INSTALLATION INSTRUCTIONS APPLICATION A. ENGAGE TABS AT TOP OF THERMOSTAT AND SUBBASE. The T7100D Microelectronic Thermostat provides electronic control of

More information

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase

T8090A/Q682B Heating, Cooling, and Heating-Cooling Thermostat, Wallplate and Subbase M75 M75 T8090A/Q68B Heating, ooling, and Heating-ooling Thermostat, allplate and Subbase SUPER TRADELINE Installation Instructions for the Trained Service Technician. Preparation heck thermostat and subbase

More information

INSTALLATION. Glass Panel Doors (select models) CAUTION

INSTALLATION. Glass Panel Doors (select models) CAUTION Location Do not install refrigerator near oven, radiator or other heat source. If not possible, shield refrigerator with cabinet material. Do not install where temperature falls below 55 F (13 C) or rises

More information

Installation and Operation Manual For Hunter Ceiling Fans

Installation and Operation Manual For Hunter Ceiling Fans Installation and Operation Manual For Hunter Ceiling Fans 1 2 CONGRATULATIONS! Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years.

More information

A19, A28 Series Thermostats for Agricultural Buildings

A19, A28 Series Thermostats for Agricultural Buildings A19, A28 Series Thermostats for Agricultural Buildings FANs 121, 125 Temperature Controls Section A Product Bulletin A19, A28 Issue Date 1088 Application These thermostats are designed for heating and

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

CT2800 Programmable Thermostat

CT2800 Programmable Thermostat CT2800 Programmable Thermostat INSTALLATION AND PROGRAMMING INSTRUCTIONS Welcome to the world of comfort and energy savings with your new Honeywell Programmable Thermostat. Your new thermostat will automatically

More information

T8034C Heating/Cooling Thermostats

T8034C Heating/Cooling Thermostats T8034C Heating/Cooling Thermostats INSTALLATI INSTUCTIS APPLICATI These T8034C Thermostats control 4 to 30 Vac singlestage heating-cooling systems. An spdt mercury switch makes (H) to on temperature fall

More information

C6097A,B Pressure Switches

C6097A,B Pressure Switches C6097A,B Pressure Switches FEATURES PRODUCT DATA APPLICATION The C6097 Pressure Switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 8 Models Owner s Guide and Installation Manual Model No. Catalog

More information

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings. L Honeywell THE L4068A,C,E,F FAN CONTROLS OPER- ATE THE FURNACE FAN MOTOR IN RESPONSE TO PLENUM TEMPERATURE IN FORCED AIR HEATING SYSTEMS. ATTIC FAN CONTROL OPERATES AN ATTIC VENTILATION FAN IN RE- SPONSE

More information

Powers TM Controls ET 134 Line Voltage Room Thermostats

Powers TM Controls ET 134 Line Voltage Room Thermostats Powers TM Controls ET 134 Line Voltage Room Thermostats Technical Instructions Document No. 155-017P25 ET 134-55 134-1083 134-1084 &134-1085 Exposed Knobs 134-1084 & 134-1085 Concealed Adjustment 134-1086

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual Tribeca Owner s Guide and Installation Manual English Form# M6001-01 20120416 2012 Casablanca Fan Co. Welcome Your new Casablanca ceiling fan is an addition to your home or office that will provide comfort

More information

T7984 A,B,C Electronic Modulating Control Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats T7984 A,B,C Electronic Modulating Control Thermostats FEATURES PRODUCT DATA APPLICATION These microprocessor-based thermostats provide proportional - integral (PI) individual room temperature control in

More information

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING. 21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING www.anvilworld.com 20 ALL ANVIL EQUIPMENT COMES WITH A ONE YEAR WARRANTY ON COMPONENTS AND DEFECTIVE WORKMANSHIP. www.anvilworld.com 19 20 LITER

More information

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats T8624D Chronotherm IV Deluxe mable Multistage Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8624D Chronotherm IV Deluxe mable Multistage Thermostats provides electronic control of 24 Vac single-zone

More information

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers Electronic Pool and Spa Controllers The L8005A,B and LS8005A,C,D Electronic Pool and Spa Controllers are used in pool, spa, and hot tub applications to control water temperature. Remote Potentiometer L8005A,B

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Date Purchased

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL Style that revolves around you. CEILING FAN OWNER S MANUAL Total fan weight *53 lbs. WEXFORD 11/05 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Installation Instructions

Installation Instructions Dear customer! Thank you for choosing this quality product from ASKO. We hope it will meet your expectations and fulfil your needs for many years to come. Scandinavian design combines clean lines, everyday

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL SERIES JD GAS FIRED STEAM AND HOT WATER HEATING BOILER : If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal

More information

Thermostatic Valve and Trim

Thermostatic Valve and Trim ML8950-xx Thermostatic Valve and Trim Description Installation instructions Trim and PL8950 valve Brass lever handles and face plate Standards ASME A112.18.1 Listed IAPMO / UPC & CUPC ADA Accessibility

More information

T7200D,E Series 2000 Commercial Microelectronic Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats T7200D,E Series 2000 Commercial Microelectronic Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T7200D,E Thermostats provide electronic control of 24 Vac commercial single-zone heating, ventilating

More information

ACQUITY UPLC HT Column Heater Instructions

ACQUITY UPLC HT Column Heater Instructions ACQUITY UPLC HT Column Heater Instructions Note: This document is an addendum to Revision C of the ACQUITY UPLC System Operator s Guide. Contents: Topic Page Overview 1 Connecting the cable 4 Installing

More information

Undercounter Refrigeration

Undercounter Refrigeration INSTALLATION GUIDE Undercounter Refrigeration Contents Undercounter Refrigeration..................... 3 Undercounter Specifications.................... 4 Site Preparation..............................

More information

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.817 Date: july 23, 2015 Supersedes: 10.817 Date: june 3, 2015 1.0 Typical installations 1 2.0 How it works

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

T6984F,G Electronic Floating Control Thermostats

T6984F,G Electronic Floating Control Thermostats T6984F,G Electronic Floating Control Thermostats FEATURES PRODUCT DATA P+I control action provides accurate, stable room temperature control. Used with ML644 Series 60 Direct Coupled Damper Actuators.

More information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................

More information

CP CP

CP CP CP-8161-333 CP-8161-433 Electronic Programmable Controller Six Stage, Dual Setpoint General Instructions APPLICATION Electronic six stage programmable controller with proportional output for heating, cooling

More information

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

MODEL /4 Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload 2900 FIREGUARD Electromechanical Closer-Holder Device Models 12-2960, 9-2960 and 2960 Multipoint Hold Open with Rigid Arms Pull (Hinge) Side Installation Instructions CAUTION: FAILURE TO INSTALL OR ADJUST

More information

Marsal Deck Ovens: MB42, MB60, MB236, MB866, SD236, SD248, SD260, SD448, SD660, SD1048, SD1060, SD866, SD10866, WF42, WF60

Marsal Deck Ovens: MB42, MB60, MB236, MB866, SD236, SD248, SD260, SD448, SD660, SD1048, SD1060, SD866, SD10866, WF42, WF60 OVEN SERVICE MANUAL Marsal Deck Ovens: MB42, MB60, MB236, MB866, SD236, SD248, SD260, SD448, SD660, SD1048, SD1060, SD866, SD10866, WF42, WF60 RETAIN THIS MANUAL FOR FUTURE REFERENCE 2016 Marsal Pizza

More information

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed. Table of Contents Congratulations on purchasing your new Hunter ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

ELSTON 52 CEILING FAN

ELSTON 52 CEILING FAN ELSTON 52 CEILING FAN MODEL #10290 Español p. 21 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am -

More information

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat INSTALLATION INSTRUCTIONS APPLICATION The T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat pump

More information

Rada 320R Installation and Maintenance

Rada 320R Installation and Maintenance ALIB-320R-B Rada 320R Installation and Maintenance Water Temperature Controls Recirculation Systems Thermostatic This Rada 320R Valve has been supplied for this application based upon information provided

More information

HE120, HE160 Humidifier Installation Kit

HE120, HE160 Humidifier Installation Kit HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and

More information

52 BARSTOW CEILING FAN

52 BARSTOW CEILING FAN 52 BARSTOW CEILING FAN Owner s Manual Models #20519 If a problem cannot be remedied or you are experiencing difficulty with installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

Commercial/Industrial Combustion Control Level Three Announcement

Commercial/Industrial Combustion Control Level Three Announcement Commercial/Industrial Combustion Control Level Three Announcement SUBJECT: C6097 requiring venting Model Numbers Affected: C6097A and B Ref. Number L3-08-006 Issue Date 12/9/08 Author P.Yuen/L.Ziller Date

More information

Installation and Operation Manual For Hunter Ceiling Fans /16/2004

Installation and Operation Manual For Hunter Ceiling Fans /16/2004 Installation and Operation Manual For Hunter Ceiling Fans 1 2 CONGRATULATIONS! Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS ComfortSense 3000 Series Models / / 5/2 Day Programmable Thermostats RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE // 5/2 Day Programmable

More information

15R HARDWARE INSTALLATION GUIDE

15R HARDWARE INSTALLATION GUIDE 15R HARDWARE INSTALLATION GUIDE Table of Contents Section 1 Ratings....................................................................... 3 Section 2 Site Preparation................................................................

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents.   What to Expect with. Tools Needed. Mounting Options. Blades Table of Contents 1.888.830.1326 Ceiling Bracket 30 inches Ladder Downrod 3 Wiring 10 Operation, Maintenance & Cleaning Light Kit 11 Troubleshooting??? 17 15 1 13 5 Blades 9 Switch Housing 12 Canopy 6

More information

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models M75 M75 Installation Instructions Thermometer Scale Range: 45 o F to 85 o F [7 o C to 29 o C]. Electrical Ratings: 24 to 27 Vac. CT70A Heat Pump Thermostat Do-It-Yourself Models Your Honeywell Thermostat

More information

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS Model BK Manually led Blower Model BKT Thermostatically led Blower WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong

More information

TC-5231 Series, TC-5232, & TC-5241 Series

TC-5231 Series, TC-5232, & TC-5241 Series TC-5231 Series, TC-5232, & TC-5241 Series Low Temperature Thermostats General Instructions Application The TC-5231, TC-5232, and TC-5241 low temperature thermostats are used to control temperature in air

More information

Astro Express 2 - Hot Water Delivery System

Astro Express 2 - Hot Water Delivery System FILE NO.: 10.817 DATE: Apr. 4, 2011 SUPERSEDES: 10.817 DATE: Feb. 24, 2010 INSTALLATION AND OPERATING INSTRUCTIONS Astro Express 2 - Hot Water Delivery System TYPICAL APPLICATIONS The Armstrong Astro Express

More information

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents IAQ HUMIDIFIERS Litho U.S.A. 2007 Dallas, Texas, USA 505,289M 08/2007 Supersedes 02/2007 KAZ # C.6046 HCWB2 & HCWP2 SERIES USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS Table Of Contents Introduction....................................

More information

52 SAN LUCAS CEILING FAN

52 SAN LUCAS CEILING FAN 52 SAN LUCAS CEILING FAN Owner s Manual Models #20551 If a problem cannot be remedied or you are experiencing difficulty in installation, please contact the Service Department: 1-877-459-3267, 9 a.m.-

More information

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover Document No. 155-524P25 ET RAB-1 Description Two-wire, gas diaphragm-based fan coil room thermostat with heating or cooling sequence

More information

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS Page 1 of 10 THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS Purpose of Manual The purpose of this manual is to provide operating, servicing and repair instructions for the Summit standard models ThermaPhase

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HCB 1560/1561 HC 1550 7084 327-00 Important Please Read and Follow these Instructions These instructions contain Danger,

More information

installation and operation manual for Hunter Ceiling Fans

installation and operation manual for Hunter Ceiling Fans For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation

More information

Integrated Refrigeration

Integrated Refrigeration INSTALLATION GUIDE Integrated Refrigeration Contents Integrated Refrigeration....................... 3 Model Specifications.......................... 4 Site Preparation.............................. 6

More information

A B A B4

A B A B4 TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity

More information

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY

More information

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation Instructions HE-67xx Issue Date 0501 TRUERH Series HE-67xx Humidity Element with Temperature Sensor Installation IMPORTANT: The HE-67xx Series Humidity Element with Temperature Sensor is designed

More information

TOUCHDOWN 48 CEILING FAN

TOUCHDOWN 48 CEILING FAN TOUCHDOWN 48 CEILING FAN MODEL #50205 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am

More information

Conversion of Gazco Upgradable Controls to Battery Remote Control

Conversion of Gazco Upgradable Controls to Battery Remote Control Conversion of Gazco Upgradable Controls to Battery Remote Control Ensure that combustible materials are not placed next to or on top of the appliance when using this control. Especially when using the

More information

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat 1.0 GENERAL 1.1 Overview GUIDE SPECIFICATION The contractor shall furnish, install, and place in operating condition an HVAC

More information

T8611M Deluxe Programmable Heat Pump Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats T8611M Deluxe mable Heat Pump Thermostats INSTALLATION INSTRUCTIONS APPLICATION The T8611M Deluxe mable Heat Pump Thermostat provides electronic control of 24 Vac single-zone two compressor or two speed

More information