Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)
|
|
- Wilfrid Hopkins
- 5 years ago
- Views:
Transcription
1 Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units) Takuya ITO Mitsubishi Electric Corporation 1
2 Biography Belonging The Air-conditioning & Refrigeration systems works Have developed the chiller since 1997 Planning new product & design Takuya ITO Mitsubishi Electric Corporation 2
3 Procedure of presentation 1. Background Purpose 2. Features of DT-R 3. Energy-saving technology and downsizing technology 4. Simplification of multiple installation construction 5. High efficiency by the multiple module control 6. Conclusions 3
4 1. Background Purpose (1) Air-cooled heat pump chillers The chillers are usually used as a central heat source machine for outdoor air processing, air condition or process cooling. The chillers have been taken notice of effectiveness to prevent global warming to reduce the refrigerant of the indoor unit. Outdoor unit Air-cooled heat pump chiller Indoor unit Air heat exchanger expansion valve Water heat exchanger Water coil 4 way valve Refrigerant pipe Compressor ACC (Accumulator) Water pipe Pump General air conditioning system(chiller) 4
5 1. Background Purpose (2) Chiller s market A further improvement of performance was requested for both 100% load and part load conditions from the viewpoint of global warming prevention. A smaller footprint and more capacity is needed. developed the high efficiency, compact new air-cooled heat pump chiller DT-R 5
6 2. Features of DT-R (1) Y-structure The lack of service space is solved between machine rooms by Y-structure. (2) The highest EER in chiller market(2015/10) The EER(50HP 3.47) is achieved by using high performance device of refrigeration circuit. Part load performance is better than conventional machines due to the mounted inverter compressor. (3) High efficiency due to the multiple module control DT-R is designed for high-efficiency operation that can control a number of units during multiple operations. Y-structure machine room Service space of machine room the side view (2 connected units) Performance DT-R Horsepower 60HP 50HP Cooling Capacity(kW) EER SEER Heating Capacity(kW) COP Dimension 2,350(H) 1,080(W) 3,400(D) Refrigerant R410A Capacity per area(kw/m 2 ) Difference of inlet and outlet water temperature is 7 degree celsius 6
7 3. Energy-saving technology and downsizing technology 7
8 3. Energy-saving technology and downsizing technology (1) Air heat exchanger 1) The new slit fin of high heat transfer rate The heat transfer rate was improved against our conventional unit by increasing the thermal boundary layer. 2) Large diameter fan The flow rate was increased against our conventional unit. Large diameter fan Air heat exchanger The ring fin of our conventional unit The new slit fin of DT-R (the ZIGZAG slit fin) The new slit fin and large diameter fan 7
9 3. Energy-saving technology and downsizing technology 3) High efficiency mounting DT-R was shaped for intake from all four sides by mounting the four L-bend air heat exchangers diagonally downsizing of the unit and to reduce space with multiple installation, Air discharge Inlet air from four directions Air Intake Mount diagonally Air discharge Air Intake Air Intake Air Intake (a) External (b) Top view (c) Front view 9
10 3. Energy-saving technology and downsizing technology (2) dual inverter(high-efficiency scroll compressor and fan motor) 1) inverter compressor The inverter compressor reaches maximum EER when at about 60% capacity. 2) inverter fan motor the flow rate is low the air heat exchanger cannot function sufficiently. the flow rate is high fan motor input is increased DT-R can drive at high efficiency due to rotational speed control for optimum air flow rate in accordance with the operating conditions of the unit. 120% 110% EER ratio 110% 100% 90% 80% 70% 60% Scroll compressor (Inverter capacity control) Screw compressor (Mechanical capacity control) EER ratio 100% 90% 80% Input Increase by high-pressure rise The best air flow rate Fan input increase 50% 20% 30% 40% 50% 60% 70% 80% 90% 100% Cooling capacity ratio Comparison of compressor performance 70% 40% 60% 80% 100% 120% Air flow ratio Performance to change in air flow rate 10
11 3. Energy-saving technology and downsizing technology (2) dual inverter(high-efficiency scroll compressor and fan motor) <Part load performance(air temp. :35, Water temp. 7 > Optimum control of compressor frequency fan rotational speed according to load EER ratio 125% (at 55% capacity) 130% Air temp. :35 Outlet water temp. :7 EER ratio 120% 110% 100% +25% 90% Cooling capacity ratio(%) Part load performance of DT-R 11
12 3. Energy-saving technology and downsizing technology (3) Two evaporation temperature cycle 1) Independent refrigeration cycle connected in series on the water side 2) Improvement of EER by raising the evaporation temperature on the upstream side of cold water. Air heat exchanger 4-way valve Circuit 1 Circuit 3 expansion valve Compressor Water heat exchanger Refrigeration cycle of DT-R Upstream Circuit 2 Circuit 4 Downstream Evaporation temp. difference against 1-evap cycle ( ) EER ratio % 103% 102% 101% 100% 99% 98% 97% 96% Difference of water temperature upon entrance and exit( ) 2% % 2-evap.-cycle 1-evap.-cycle Difference of water temperature upon entrance and exit( ) 12
13 3. Energy-saving technology and downsizing technology (4) Module coupling structure By connecting the module, DT-R achieved a great reduction of installation space. <Air Intake space> Because of the Y-shaped structure, It s easy for air intake even with consolidated installation. Y-shaped structure Side view of 3 connected units 13
14 3. Energy-saving technology and downsizing technology (4) Module coupling structure <Comparison of installation area with conventional model(300hp)> The installation space was 48% compared with the conventional machine greatly reducing the installation area space requirements.. Installed areas 38.5m 2 (48%) Installed areas 79.9m 2 (100%) (a)development model (60HP 5) (b) Conventional model (100HP 3) Comparison of installation areas 14
15 4. Simplification of multiple installation construction 15
16 4. Simplification of multiple installation construction < Selectable water piping specifications> 1.Standard piping can be adopted to and customized for various system. 2.Built-in header establish header pipe connection for each module (collection piping) in the machine room. Piping space can be reduced. Piping space can be reduced Standard piping Built-in header 16
17 4. Simplification of multiple installation construction It can easily be constructed and shorten the construction period by reducing the connection points and the piping space at the time of multiple installation. Piping space can be reduced Plumbing connection point Built-in header Plumbing at the site The piping inside the module (Install at the factory) Example of built-in header 17
18 5. High efficiency by the multiple module control 18
19 5. High efficiency by the module multiple control 1.Control of each module Outlet water temperature constant control Optimum control of the number of compressors and frequency and fan rotation speed so that outlet water temperature is constant 2. multiple module control determines the number of units based on the amount of the compressor frequency of all units. Outlet water 空調負荷 空調負荷 Remote controller 17
20 5. High efficiency by the multiple module control EER ratio at multiple system(60hpx4) keeping high EER to min-load. Determine the optimal number of module. 130% 1-unit 2-unit 3-unit 4-unit 120% EER ratio 110% 100% Keeping 110%-EER ratio +20% 90% 4-UNIT (No number of control) 80% 0% 20% 40% 60% 80% 100% Cooling capactity ratio Comparison of part-load performance of the multiple numbers of controls 20
21 5. Conclusions The new type chiller DT-R was developed to improve the energy saving and the installation area of air-cooled heat pump chiller. 1. The top level of EER3.47(50HP) and in chiller market was achieved by high performance devices. 2.DT-R has achieved a 48% smaller footprint than conventional machines by the following technology: a) By the New-Y-Shape structure, the modules can connect unit to unit and the space between the modules can be eliminated. b) By using highly-efficient inverter compressors and adopting highly-efficient small air heat exchangers equipped with Zigzag-slit fins, we were able to achieve both high-efficiency and small installation space. c) By using application of highly-efficient 2-evaporation temperature cycles, we were able to achieve the reduction in the water heat exchanger. 21
22 5. Conclusions We will continue to push further for high efficiency, compact designs and global environment friendly products. Thank you all very much for your attention. 22
COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd
COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd Abstract This paper presents the design approach adopted for the expansion of a large existing
More informationAir / Water Heat Pump - Compact Design Modulating 8 18 kw
Air Ground Water Air / Water Heat Pump - Compact Design Modulating 8 18 kw Heliotherm Sensor Comfort Compact A modulating air / water heat pump in compact design for outdoor installation for generous sized
More informationTranscritical CO2 Bottle Cooler Development
Transcritical CO2 Bottle Cooler Development C. Rohrer Ingersoll Rand Climate Control, 12999 St. Charles Rock Rd. Bridgeton, MO, United States 314 298-4765, clay_rohrer@irco.com ABSTRACT This paper contains
More informationHigh-efficiency Turbo Chiller (NART Series)
67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration)
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationDAIKIN Modular Inverter Air Cooled Chiller
DAIKIN Modular Inverter Air Cooled Chiller R410A ODP=0 R410A ODP=0 R410A ODP=0 R410A ODP=0 1 EVOLUTION ULTIMATE DAIKIN has achieved a wealth of world s firsts over the last three centuries. Based on four
More informationAIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT
AIR TREATMENT ReCOOLER HP ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT Energy efficiency the essence of our solutions All our research, development
More informationUnit Width. 900mm. Service Space Internal Header. 1st. Unit. 2nd. Coupling supplied as standard. Unit
900mm Unit Width 900mm Service Space Internal Header 1st Unit Coupling supplied as standard 2nd Unit Low noise levels By utilizing highly efficient components within a uniquely shaped chiller, the e-series
More informationMODULAR CHILLER. R410a R22
Ra R 3 Ra/-0 R/-0 New ppearance New Y-shape design, more fashion IR-COOLED SERIES (Ra) Compressor ir cooling side heat exchanger Best scroll compressor, low sound power level, By using calculation model
More informationMRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design
Special Heat Exchanger Design 4 way air return heat exchanger design Reduce the heat exchanger height (6mm), and the upper and lower wind speed uniform and high efficiency. Air Supply Chamber and Equipment
More informationAll series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.
HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types
More informationNew CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF
New CGAF New Air-Cooled Scroll Chiller CGAF New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2 New addition to the Sintesis Family: Multiple technologies,
More informationSUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP
VEP075N432G Job Name: Location: Schedule No.: System Designation: Engineer: Architect: Date: For: Reference Approval Review Construction FEATURES Two-pipe heat pump Access to electrical box for ease of
More informationTEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #43 System Drop-in Tests of Refrigerants L-41-1, L-41-2, and
More informationAQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING
Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More information2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating
2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial
More informationYORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS
YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS Efficiency-optimized Heating and Cooling for Best-in-class Performance EC Fans Brazed Plate Heat Exchanger Condenser Coils Optiview
More informationYORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS
YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS Efficiency-optimized Heating and Cooling for Best-in-class Performance EC Fans Brazed Plate Heat Exchanger Condenser Coils Optiview
More information50A KP 70A KP 90A KP 120A KP 150A KP 210A
DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw
More informationDunham Bush Air Cooled Screw Chiller AFVX B 6SR Series
Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR
More informationIntroduction of Panasonic New CO2 refrigeration system (Technical Part)
Introduction of Panasonic New CO2 refrigeration system (Technical Part) Feb. 3 rd 2015 Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division Hidekazu Tachibana # 1 AGENDA Number
More informationAir Cooled Packaged Systems AIRAH Back to Basics
Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability
More informationHVAC Water chiller selection and optimisation of operation
HVAC Water chiller selection and optimisation of operation Introduction Water-chiller is a broad term describing an overall package that includes an electrical control panel, refrigeration plant, water
More informationIncrease your flexibility.
DVM CHILLER Increase your flexibility. Get the best of two worlds. This easy to expand, modular unit combines the benefits of VRF and Chiller systems. Product Registration Required Conditions Apply 2018
More informationDevelopment of Automotive Air-Conditioning Systems by Heat Pump Technology
27 Development of Automotive Air-Conditioning Systems by Heat Pump Technology TOSHIHISA KONDO *1 AKIRA KATAYAMA *1 HIDEKI SUETAKE *1 MASATOSHI MORISHITA *2 In the future, the market for electric and hybrid
More informationAir-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a
Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition
More informationEN aquatech.piovan.com
EN aquatech.piovan.com Refrigeration Technologies: scroll-compressor chillers The scroll compressor is the most suitable component for the small and medium duty requirements in the industrial applications.
More informationAIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw
COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationVRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group
VRF D4 PLUS System Digital Scroll Series GD Midea Heating & Ventilating Equipment Co., Ltd. Is certified under the ISO 9001 International standard for quality assurance. NO.01 100 019209 GD Midea Heating
More informationTechnical Information
Date of last update: 02-08 Ref: Application Engineering Europe COPELAND SCROLL COMPRESSORS USING VAPOUR INJECTION FOR REFRIGERATION CONTENTS 1 Introduction...1 2 Principle of Operation...1 3 Capacity Effect...2
More informationApplication Engineering
Revised September, 2006 ECONOMIZED VAPOR INJECTION (EVI) COMPRESSORS INDEX SECTION PAGE 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 3 4. ARI Low Temperature Ratings... 3 5. Approved
More informationPAC BT LOW TEMPERATURE HEAT PUMP
PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter
More informationBLUEWAY DC INVERTER AIR TO WATER HEAT PUMP
BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP 1 Enjoy comfortable life with BLUEWAY DC Inverter Air to Water Heat Pump is an innovative system of house heating, domestic hot water and even space cooling,
More informationPresented By: John Dolan, P.E.
Variable Speed Compressor Technologies Presented By: John Dolan, P.E. President - Thermosystems, Inc. BS in Mechanical Engineering from UIUC 29 years HVAC Equipment Application Experience jdolan@thermohvac.com
More informationDC Inverter Smart VRF Products(R410A)
DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is
More informationHeat pump & cooling unit in one
+ + Heat pump & cooling unit in one The reversible ThermoCooler HP heat pump can be integrated in our Envistar Flex units. All parts of the cooling/heating pump are incorporated in a module section, which
More informationKawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto
Kawasaki centrifugal chiller using water as a refrigerant Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto Contents 1. Introduction of MiZTURBO 2. Study of CO 2 emissions
More informationThe Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2002 The Development Of High Efficiency Air Conditioner With Two Compressors
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationTrailblazer air cooled scroll chillers
Trailblazer air cooled scroll chillers Changing the way you think about air cooled chillers 30 to 240 tons with Variable Speed Condenser Fan Technology People and ideas you can trust. Changing the way
More informationAir Conditioning System
For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationThe next level of energy efficiency and flexibility
The next level of energy efficiency and flexibility Flexcool, utmost flexibility of application and efficiency of operation from Aquatech Innovation always comes from paradigm shifts Aquatech, one of the
More informationVariable refrigerant flow (VRF) systems
SBS5311 HVACR II http://ibse.hk/sbs5311/ Variable refrigerant flow (VRF) systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents System Overview Components
More informationDrink Showcase Equipped with Inverter Freezer
Drink Showcase Equipped with Inverter Freezer MURABAYASHI, Kenji KAGEYAMA, Toshiyuki CHOU, Ikou ABSTRACT In recent years, the impact of earthquakes has increased the demand for replacing products with
More informationIntroduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division
Introduction of Panasonic CO2 refrigeration system Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division Compressor New Model Outdoor Small Size CO2 Refrigeration Unit CO2
More informationReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit
ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit 28 May 2013 Agenda Introduction to Fläkt Woods Our Product Solution Technical Features Benefits Fläkt Woods Index We save energy!
More informationAir-cooled modular Chiller. Nick Technical Engineer
Air-cooled modular Chiller Nick Technical Engineer Product line-up Features Roadmap Product range New product Comparison Reference project Product roadmap Entered air cooled modular chiller market T1/T3
More informationNEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!
NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart! WWW.SALDA.LT 2016 Ver. A SECTION OF THE ROTARY HEAT EXCHANGER WITH THE HEAT PUMP: ideal solution targeting multiple goals In conventional
More informationExecutive Summary. Number of Low Number of High Number of Faults , Number of OK
Unit Lower limit Upper limit Air on Model no evap. F Air off evap. F dt air evap. F Executive Summary Evapo. F This is a summary chart for quick reference and view of all the systems tested. Red boxes
More informationExperimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract
Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant M. Honma, T. Tamura, Y. Yakumaru and F. Nishiwaki Matsushita Electric Industrial Co., Ltd. Living Environment
More informationWater-cooled chillers with High Speed Centrifugal Compressors
Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and
More informationDevelopment of R744 Two Stage Compressor for Commercial Heat Pump Water Heater
Purdue University Purdue epubs International Compressor Engineering Conference School of Mechanical Engineering 2012 Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater Youhei
More informationINVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.
LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /
More informationWATE R -C OOLE D WATE R C H ILLE R S
WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationVariable Refrigerant Flow (VRF) Systems
Variable Refrigerant Flow (VRF) Systems Flexible Solutions for Comfort Carrier Corporation Syracuse, New York January 2013 TABLE OF CONTENTS INTRODUCTION... 2 VRF TECHNOLOGY... 2 ADVANTAGES OF A VRF SYSTEM...
More informationEnergy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings
- 1 - Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings Mamoru Hamada, Living Environment Systems Laboratory, Mitsubishi Electric Co., Kamakura, Kanagawa, Japan Naomichi
More informationChillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw
Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative
More informationCopeland Scroll Outdoor Refrigeration Unit
Copeland Scroll Outdoor Refrigeration Unit Medium and low temperature applications Convenience Store Restaurant R-22, 134a, 404A/507A, 407C/A, 448A/449A 1.5-6 HP Innovative design based on three factors
More informationINVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by
4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies
More information"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range
3 "ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range YOSHIE TOGANO *1 JUN MIYAMOTO *1 YOSHIE KANKI *1 KAZUMI SHIMIZU *1 TAKAAKI MIURA *2 YASUSHI HASEGAWA *3 In
More informationDevelopment of multi-function CO2 Heat Pump Water Heater
Development of multi-function CO2 Heat Pump Water Heater Background of multi-function water heater Market trend of gas combustion multi-function water heater X1000 400 200 1996 1997 1998 1999 2000 2001
More informationMRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor
1 7 Features & Benefits 17 Outdoor 5 6 (SIDE DISCHARGE) OUTDOOR STRUCTURE (/1/12HP SIDE DISCHARGE) More Bigger Outdoor Capacity, More Flexible Application High efficiency DC fan motor Vector inverter control
More informationIntegrated VarIable refrigerant flow ahu/pau (r410a)
Integrated Variable Refrigerant Flow AHU/PAU (R410A) CONTENTS Features of VRF AHU/PAU 2 WELAIRE i-gt Concept 9 VRF Outdoor Unit Performance Data 10 Drawings & Performance Data 12 Dimensions 13 Notes 14
More informationSUBCRITICAL & TRANSCRITICAL SYSTEMS
R744 CO2 SYSTEMS SUBCRITICAL & TRANSCRITICAL SYSTEMS ORIGINAL MANUFACTURED EQUIPMENT R744 CO2 Systems BA-508-3 AUS In 2004 BITZER Australia introduced the Enviro-Cold CO 2 System to the Australian Refrigeration
More informationChillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps
Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant
More informationPassion & Innovation: The Enertech Team. Member
Passion & Innovation: The Enertech Team Member IGSHPA 2011 C ONFERENCE 15 years of solutions in promoting geothermal heat pump technology 4 years as a manufacturer 100+ years of collective experience in
More information1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.
MAKING MODERN LIVING POSSIBLE Most valves expand your refrigerant EcoFlow expands your options 25% COP boost possible with silent defrost. 1+ SEER energy savings Reduce energy consumption and increase
More informationPowerful and reliable. Also for high ambient temperatures. weco Compact chillers
Powerful and reliable. Also for high ambient temperatures. weco Compact chillers The smart approach to cooling. Energy-effic Innovative technology The new compact chillers are equipped according to the
More informationProcess glycol chillers
Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic
More informationDevelopment of centrifugal chiller and heat pump using low GWP refrigerant
Development of centrifugal chiller and heat pump using low GWP refrigerant Ryosuke Suemitsu 1*, Naoya Miyoshi 1, Yasushi Hasegawa 1, Kazuki Wajima 1, Yoshinori Shirakata 1, Kenji Ueda 1 1 Mitsubushi Heavy
More informationCOMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz
COMMERCIAL AIR CONDITIONERS R40A All DC Inverter VRF V5 X Series 50/60Hz Midea CAC (MCAC) As a key subsidiary of Midea Group, the Midea Central Air Conditioner (MCAC) business unit has emerged as a leading
More informationNRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER
NRP MULTIPURPOSE HEAT PUMPS AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER Multipurpose air cooled units with axial fans. For external installation. High efficiency version. NRP MULTIPURPOSE
More informationPRODUCT GUIDE
PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency
More informationA Complete Line Of Remote Rack Refrigeration Systems
A Complete Line Of Remote Rack Refrigeration Systems Choosing The Right Rack Refrigeration System DRS Series Dual Compressor Systems For combination cooler/freezer walk-ins, DRS systems provide a hermetic
More informationHow to Cut Chiller Energy Costs by 30%
How to Cut Chiller Energy Costs by 30% Pre-packaged retrofit cuts centrifugal compressor chiller energy costs by 30% while reducing required maintenance and extending operating life at Duke Realty Corporation
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationGEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers
GEA Blu chillers GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers 3 Balanced to your benefit, in a class of their own Whether for food and beverage industry, process
More informationETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming
ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming 88 KENJI UEDA *1 YOSHINORI SHIRAKATA *2 YASUSHI HASEGAWA *3 NORIYUKI MATSUKURA *4 NAOYA MIYOSHI
More informationSession: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island
Session: HVAC 101 HVAC 101 Steve Sain Sain Engineering Associates, Inc. August 9, 2016 Rhode Island Convention Center Providence, Rhode Island Why? 2 Acknowledgements 3 Disclaimer I m gonna shoot down
More informationPPL Electric Utilities Energy Efficiency and Conservation Program
Installation of High-Efficiency High Efficiency Evaporator Fans Evaporator Fans That have Highfor Walk-ins Efficiency Permanent Split $50/fan motor Capacitor (PSC) Motor or ECM High Efficiency Compressors
More informationAIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw
PROCESS CHILLERS HEAT PUMPS AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION 17-290 kw climaveneta.com PROCESS CHILLERS HEAT PUMPS A TRULY UNIQUE SOLUTION
More informationrecooler HP EQKR HEAT PUMP
AIR COMFORT AIR TREATMENT 9566 GB 2016.03.17 recooler HP EQKR HEAT PUMP» TECHNICAL CATALOGUE 2 ReCooler HP EQKR Technical Catalogue Content ReCOOLER HP EQKR HEAT PUMP 3 product presentation. 3 applications.
More informationA new method for preventing air-source heat pumps and refrigerators from frosting
12 th IEA Heat Pump Conference 2017 A new method for preventing air-source heat pumps and refrigerators from frosting Central Research Institute of Electric Power Industry L. Zhang, T. Fujinawa, K. Hashimoto*,
More informationInverter Wall Mounted Series
PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia
More informationAir cooled industrial chillers
Air cooled industrial chillers Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationNoise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 004 Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow
More informationA New Dedicated Outdoor Air System with Exhaust Air heat recovery
12 th IEA HEAT PUMP Conference Paper number O1.2.4 A New Dedicated Outdoor Air System with Exhaust Air heat recovery GREATLAB Zi-Yang Zhang, Xiang Cao, Zhi Yang, Liang-Liang Shao, Chun-Lu Zhang, Yue Yu
More informationENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS
ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering,
More informationGeneral HVAC Recommendations
General HVAC Recommendations DESIGN GUIDELINES FOR ENERGY EFFICIENT HVAC SYSTEMS Thank you for your interest in energy efficiency! Energy efficient heating, ventilation, and air conditioning (HVAC) equipment
More informationSystem Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller
System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller Satheesh Kulankara, William McQuade, Scott Rauch and
More informationThe analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.
Comparison of R134a and R1234ze for New Chiller Systems and for Fluid (Drop-In) in Existing Systems Francis A. Di Bella, P.E. Adam Weaver Colin Osborne Executive Summary A chiller cycle analysis is presented
More informationSPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing
SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated,
More informationMechanical Systems Mechanical Systems
VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell
More informationSWIMMING POOL HEAT PUMPS
WHAT IS A POOL HEAT PUMP? Swimming pool heat pumps extract the heat stored in the ambient air and transfer it to water. It increases the water temperature to reach the desired level. Comparatively, it
More informationRED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers
RED DOT UNITS R-1630 Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL The R-1630 combines powerful heating and cooling with the compact profile you need for tight spaces. It easily
More information