Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES

Size: px
Start display at page:

Download "Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING BILLS OF QUANTITIES"

Transcription

1 Nairobi Funeral Home and Forensics VENTILATION AND AIR CONDITIONING ILLS OF QUANTITIES 26/10/2015

2 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR SERVER ROOM The air conditioning system shall be split type. The indoor unit shall be high wall type air-cooling unit. The air conditioning unit shall be supplied complete with room thermometer, room thermostat controls and wireless remote control device. It shall charged with R410A refrigerant or any other non ozone depleting refrigerant. The unit shall be such that if the power supply goes off, it will start automatically after power is restored with three minute delay. The outdoor unit shall have matching capacity with the indoor unit. The unit shall be Samsung Model or equal and approved. The indoor unit shall have the following capacity: A 7.1KW (24,000 tu/hr) Refrigeration Pipework Refrigeration liquid line pipework including 25mm Amaflex insulation. 2 No. 40 LM C Refrigeration gas line pipework including 25mm Amaflex insulation. 40 LM D E F Drain 25mm PVC condensate drainage pipework, class D, including bends, clips, joints and tees in the running lengths of the pipe. 16 LM Surge Protector Power surge protector as Solatek to suite or equal and approved. Electrical Works Allow for associated electrical works from the local isolator provided by others within one meter to the air conditioning units and wiring from indoor unit to outdoor unit. 2 No. G H Mounting bracket Mounting bracket for the outdoor unit complete with a cage and provided with purpose-made protective steel iron angle frame and all other anchoring accessories including rawl bolts and anti-vibration rubber mountings to engineer s approval. Wall Mounted Wired Remote Controller Fully wired wall mounted remote controller panel complete with digital display, wiring and conduit works including but not limited to interconnecting cable between the outdoor and indoor units. 2 Item 2 No. I Trunking 75x50mm approved PVC trunking for concealing the refrigerant pipework. 18 LM Total Carried Forward to Air Conditioning Collection Page Q 5 Q 1

3 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR OARDROOMS The air conditioning system shall be split type. The indoor unit shall be high wall type air-cooling unit. The air conditioning unit shall be supplied complete with room thermometer, room thermostat controls and wireless remote control device. It shall charged with R410A refrigerant or any other non ozone depleting refrigerant. The unit shall be such that if the power supply goes off, it will start automatically after power is restored with three minute delay. The outdoor unit shall have matching capacity with the indoor unit. The unit shall be Samsung Model or equal and approved. The indoor unit shall have the following capacity: A 10.4KW (36,000 tu/hr) 2 No. 7.1KW (24,000 tu/hr) 2 No. C Refrigeration Pipework Refrigeration liquid line pipework including 25mm Amaflex insulation. 60 LM D Refrigeration gas line pipework including 25mm Amaflex insulation. 60 LM E Drain 25mm PVC condensate drainage pipework, class D, including bends, clips, joints and tees in the running lengths of the pipe. 36 LM Surge Protector F Power surge protector as Solatek to suite or equal and approved. 4 No. G Electrical Works Allow for associated electrical works from the local isolator provided by others within one meter to the air conditioning units and wiring from indoor unit to outdoor unit. H I Mounting bracket Mounting bracket for the outdoor unit complete with a cage and provided with purpose-made protective steel iron angle frame and all other anchoring accessories including rawl bolts and anti-vibration rubber mountings to engineer s approval. Wall Mounted Wired Remote Controller Fully wired wall mounted remote controller panel complete with digital display, wiring and conduit works including but not limited to interconnecting cable between the outdoor and indoor units. 4 Item 4 No. J Trunking 75x50mm approved PVC trunking for concealing the refrigerant pipework. 48 LM Total Carried Forward to Air Conditioning Collection Page Q 5 Q 2

4 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR COMPUTER ROOM The air conditioning system shall be split type. The indoor unit shall be high wall type air-cooling unit. The air conditioning unit shall be supplied complete with room thermometer, room thermostat controls and wireless remote control device. It shall charged with R410A refrigerant or any other non ozone depleting refrigerant. The unit shall be such that if the power supply goes off, it will start automatically after power is restored with three minute delay. The outdoor unit shall have matching capacity with the indoor unit. The unit shall be Samsung Model or equal and approved. The indoor unit shall have the following capacity: A 7.1KW (24,000 tu/hr) 4 No. Refrigeration Pipework Refrigeration liquid line pipework including 25mm Amaflex insulation. 80 LM C Refrigeration gas line pipework including 25mm Amaflex insulation. 80 LM D Drain 25mm PVC condensate drainage pipework, class D, including bends, clips, joints and tees in the running lengths of the pipe. 40 LM Surge Protector E Power surge protector as Solatek to suite or equal and approved. 4 No. F Electrical Works Allow for associated electrical works from the local isolator provided by others within one meter to the air conditioning units and wiring from indoor unit to outdoor unit. G H Mounting bracket Mounting bracket for the outdoor unit complete with a cage and provided with purpose-made protective steel iron angle frame and all other anchoring accessories including rawl bolts and anti-vibration rubber mountings to engineer s approval. Wall Mounted Wired Remote Controller Fully wired wall mounted remote controller panel complete with digital display, wiring and conduit works including but not limited to interconnecting cable between the outdoor and indoor units. 4 Item 4 No. I Trunking 75x50mm approved PVC trunking for concealing the refrigerant pipework. 60 LM Total Carried Forward to Air Conditioning Collection Page Q 5 Q 3

5 Item Description Qty Unit Rate Cost SPLIT AIR CONDITIONING SYSTEM FOR LAORATORIES The air conditioning system shall be split type. The indoor unit shall be high wall type air-cooling unit. The air conditioning unit shall be supplied complete with room thermometer, room thermostat controls and wireless remote control device. It shall charged with R410A refrigerant or any other non ozone depleting refrigerant. The unit shall be such that if the power supply goes off, it will start automatically after power is restored with three minute delay. The outdoor unit shall have matching capacity with the indoor unit. The unit shall be Samsung Model or equal and approved. The indoor unit shall have the following capacity: A 7.1KW (24,000 tu/hr) 22 No. Refrigeration Pipework Refrigeration liquid line pipework including 25mm Amaflex insulation. 440 LM C Refrigeration gas line pipework including 25mm Amaflex insulation. 440 LM D Drain 25mm PVC condensate drainage pipework, class D, including bends, clips, joints and tees in the running lengths of the pipe. 96 LM Surge Protector E Power surge protector as Solatek to suite or equal and approved. 22 No. F Electrical Works Allow for associated electrical works from the local isolator provided by others within one meter to the air conditioning units and wiring from indoor unit to outdoor unit. G H Mounting bracket Mounting bracket for the outdoor unit complete with a cage and provided with purpose-made protective steel iron angle frame and all other anchoring accessories including rawl bolts and anti-vibration rubber mountings to engineer s approval. Wall Mounted Wired Remote Controller Fully wired wall mounted remote controller panel complete with digital display, wiring and conduit works including but not limited to interconnecting cable between the outdoor and indoor units. 22 Item 22 No. I Trunking 75x50mm approved PVC trunking for concealing the refrigerant pipework. 160 LM Total Carried Forward to Air Conditioning Collection Page Q 5 Q 4

6 Item Air Conditioning and Mechanical Ventilation COLLECTION PAGE FOR AIR CONDITIONING WORKS Description 1 Total carried forward from page Q 1 2 Total carried forward from page Q 2 3 Total carried forward from page Q 3 4 Total carried forward from page Q 4 Total Cost for Air Conditioning Works Carried Forward to Summary Page Q 25 Q 5

7 Item Description Qty Unit Rate (KShs) (KShs) A Fume Cupboard Supply, deliver and install a class A fume cupboard of exterior dimensions of 2000mm wide x 950mm deep x 2400mm high. Fume Cupboard to be complete with sliding plexiglass face with a 12 work opening running full width of cabinet, counterbalance weight at the back, base cabinet with sliding doors, an 8 diameter exhaust collar connections,extract fan, fan flexible connectors overhead instrument control panel, and shall incorporate a Vulcathene Sink, L.P. gas outlet and a non-corrosive bulkhead light.fume Cupboard to be lined with epoxy coated Aluminium on working surface and sides. The chamber to meet OSHA standards. Fume Cupboard to be as "Method or equal and approved equivalent Fume cupboard extract fan Fume Cupboard extract fan capable of 0.4m3/s against a system pressure drop of 50N/m2. Casing of the fan to be in rigid PVC, impellers moulded in phenolic resin and motor protected by sealing coat of polyurethane compound. Fan to be complete with motor starter, Electrical control panel fixed near the Fume cupboard with ON/OFF and trip and a manual overide in the plant room, flexible connections anti-vibration mountings, supports. Fan to be as WOODS fume cupboard fan size 12 running at 1400 RPM or equal and approved equivalent. 10 No. Fume Cupboard Extract Ductwork Supply, deliver and install 200mm diameter upvc ductwork for the fume cupboard above. 200mm diameter upvc pipework class D 390 Lm C Holderbats for 200mm diameter pipework 90 Item D 200mm diameter ends 48 No. E 200mm diameter ventilating Cowls 10 No. F Weathering Slate for 200mm Ø pipe 10 No. G Weathering Apron for 200mm Ø pipe 10 No. Total Cost for Fume Cupboards Carried Forward to Summary Page Q 25 Q 6

8 Freezer ill of Quantities Item Description Qty Unit Rate (Ksh) Freezer Installation Supply, deliver, install, test and commission the following freezer equipment including all materials and fittings. A C Evaporator Unit 4.5KW fan assisted evaporator unit constructed out of hammered aluminium with white enamelled finish while the coil shall be of special copper tubing with aluminium fins.the fans shall have a range of operation up to -40 C and incorporating a thermal breaker. 1 No. The unit to be complete with an electric defrost as Guntner model or equal and approved. Semi-hermetic Condensing Unit Semi-hermetic condensing unit with capacity matching Item A above.to be as ITZER or equal and approved. 1 No. Control Panel The panel shall be complete with contactors, timers and all other accessories necessary for the automatic operation of the coldstore. 1 No. D E F G H Freezer Finishes 0.9mm (SWG 20) thick aluminium sheet fixed firmly on the coldroom walls and the roof complete with the corner panels. 1.62mm (16 SWG) thick chequared aluminium plate reinforced with GI steel sheet underneath and fixed firmly on the floor Thermal Insulation Supply and lay 50mm thick pre-fabricated insulation in two layers with a coat of vapour seal between layers as flinktone type 3 or equal and approved. Freezer Door Complete insulated kitchen coldroom door size 1900 x 900 x 175mm thick complete with rubber seals on door edges. Controls Room thermostat to cut compressor in and out, depending on the room temperature. 92 SM 20 SM 92 SM 1 No. I Dial thermometer 1 No. J Thermostatic expansion valve 1 No. K Solenoid valve 1 No. L Filter drier 1 No. M Low and high cut-out switch 1 No. N Low pressure gauge 1 No. O High pressure gauge 1 No. P Sight glass 1 No. Total Carried Forward to Collection Page Q 7

9 Item Description Qty Unit Rate Refrigerant Pipework A Refrigeration pipework complete with armflex Insulation 48 LM Refrigerant Allow for the charging of the refrigeration system with necessary amount of refrigerant for initial testing and eventual operation of the coldstore. Light Fitting C 65W vapour proof light fittings 2 No. D Anti-Vibration Mountings Anti-Vibration Mountings for the condensing unit as WOODS P.N or equal and approved. E Associated Electrical Works Allow for electrical works including but not limited to wiring and conduits from the local isolator provided by others within 2metres in the machine room to the control panel, condenser and evaporator. It shall include a push and turn safety switch near the machines in the machine room for isolation during servicing and maintenance. F As-built Drawings Maintenance and Operation Manuals Allow for as-built drawing, maintenance and operation manuals in both soft and hard copies. Three copies of the as-built drawing shall be submitted in A1 paper in a scale of 1:50 Total Carried Forward to Collection Page Q 8

10 Item COLLECTION PAGE FOR WALK-IN MORTUARY FREEZER INSTALLATION Description 1 Total carried forward from page 1 2 Total carried forward from page 2 Total Cost for Walk-in Mortuary Freezer Carried to Summary Page Q 25 Q 9

11 Coldroom ill of Quantities Item Description Qty Unit Rate (Ksh) Mortuary Coldroom Installation Supply, deliver, install, test and commission the following coldroom equipment including all materials and fittings. A C Evaporator Unit 3.5KW fan assisted evaporator unit constructed out of hammered aluminium with white enamelled finish while the coil shall be of special copper tubing with aluminium fins.the fans shall have a range of operation up to -40 C and incorporating a thermal breaker. 1 No. The unit to be complete with an electric defrost as Guntner model or equal and approved. Semi-hermetic Condensing Unit Semi-hermetic condensing unit with capacity matching Item A above.to be as ITZER or equal and approved. 1 No. Control Panel The panel shall be complete with contactors, timers and all other accessories necessary for the automatic operation of the coldstore. 1 No. D E F G H Coldroom Finishes. 0.9mm (SWG 20) thick aluminium sheet fixed firmly on the coldroom walls and the roof complete with the corner panels. 84 SM 1.62mm (16 SWG) thick chequared aluminium plate reinforced with GI steel sheet underneath and fixed firmly on the floor 20 SM Thermal Insulation Supply and lay 50mm thick pre-fabricated insulation in two layers with a coat of vapour seal between layers as flinktone type 3 or equal 104 SM and approved. Coldroom Door Complete insulated kitchen coldroom door size 1900 x 900 x 175mm thick complete with rubber seals on door edges. Controls Room thermostat to cut compressor in and out, depending on the room temperature. 1 No. I Dial thermometer 1 No. J Thermostatic expansion valve 1 No. K Solenoid valve 1 No. L Filter drier 1 No. M Low and high cut-out switch 1 No. N Low pressure gauge 1 No. O High pressure gauge 1 No. P Sight glass 1 No. Total Carried Forward to Collection Page Q 10

12 Item Description Qty Unit Rate Refrigerant Pipework A Refrigeration pipework complete with armflex Insulation 36 LM Refrigerant Allow for the charging of the refrigeration system with necessary amount of refrigerant for initial testing and eventual operation of the coldstore. Light Fitting C 65W vapour proof light fittings 4 No. D E Anti-Vibration Mountings Anti-Vibration Mountings for the condensing unit as WOODS P.N or equal and approved. Associated Electrical Works Allow for electrical works including but not limited to wiring and conduits from the local isolator provided by others within 2metres in the machine room to the control panel, condenser and evaporator. It shall include a push and turn safety switch near the machines in the machine room for isolation during servicing and maintenance. F As-built Drawings Maintenance and Operation Manuals Allow for as-built drawing, maintenance and operation manuals in both soft and hard copies. Three copies of the as-built drawing shall be submitted in A1 paper in a scale of 1:50 Total Carried Forward to Collection Page Q 11

13 Item COLLECTION PAGE FOR WALK-IN MORTUARY COLDROOM INSTALLATION Description 1 Total carried forward from page 1 2 Total carried forward from page 2 Total Cost for 1No. Walk-in Mortuary Coldroom 3 FOR TWO WALK-IN MORTUARY COLDROOMS X 2 Total Cost for 2No. Walk-in Mortuary Coldroom Carried to Summary Page Q 25 Q 12

14 Item Description Qty Unit Rate Kshs Cost Kshs Prefabricated Mortuary Coldroom Cabinet Supply, deliver, install, test and commission the following coldroom cabinet equipment including all materials and fittings. A C D E A complete prefabricated front loading mortuary cold cabinet with four or three tiers and four or three hatches. The cabinet to have one door per four vertical tiers and with labelling hatch in each tier. The chamber to be fabricated from stainless steel both internally and externaly with a minimum of 100mm thick polyurethane insulation. It shall operate between 2 to 6 degrees centigrade inside the cold chambers. The package to be complete with digital controls panel, digital electronic thermostat, fan assisted evaporator, air cooled hermatic condensor unit, internal weather proof lights, insulated door, door locking system, stainless steel in-built racks, stainless steel stretchers, stainless steel body trays in each tier and to use R404A or any other non-ozone depleting refrigerant. The cabinet to have complete refrigeration components such as thermostats, thermometer, sight glass with colour coding, thermostatic expansion valve, solenoid valve, filter drier, low and high pressure cut-off switch. The evaporator shall be placed on top of the cabinet while the condensor will be located outside the room. The unit to be as Leec modular cabinets or equal and approved 2-chamber mortuary cold cabinet for 8 bodies on three tiers/ levels with all the above items and two doors. 2 Item 2-chamber mortuary freezer cabinet for 8 bodies on four tiers/ levels with all the above items and two doors. The freezer cabinet shall operate between -18 to -30 degrees centigrade. 2-chamber mortuary freezer cabinet for 6 bodies on three tiers/ levels with all the above items and two doors. The freezer cabinet shall operate between -18 to -30 degrees centigrade. 7 Item 4 Item 3-chamber mortuary cold cabinet for 12 bodies on four tiers/ levels with all the above items and three doors. 12 Item 5-chamber mortuary cold cabinet for 20 bodies on four tiers/ levels with all the above items and five doors. 7 Item The following Refrigeration Controls. (All refrigeration controls shall be as DANFOSS or equal and approved). F Room thermostat located in each room 4 No. G Digital thermometer with a range of -40 C to 50 C 4 No. H I Refrigerant liquid pipework of hard copper tubing insulated externally with 25mm thick insulation which shall be approved before installation by the project engineer. Refrigerant gas pipework of hard copper tubing insulated externally with 25mm thick insulation which shall be approved before installation by the project engineer. 680 LM 680 LM Total Carried Forward to Collection Page Q 13

15 Item Description Qty Unit Rate Kshs Cost Kshs A Stainless steel mobile cadaver lifting trolley with a rotating tray 4 No. C Surge Protector Power surge protector as Solatek to suite or equal and approved suitable for the cold cabinets. Extract Fan Silenced extract box fan unit of duty m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. 32 No. 4 No. D E Silenced extract box fan unit of duty 0.5 m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. Control Panel Splash proof controlled panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter overload relay and overheat safety control and fuses. The control panel to operate two fans and with light indicators. 4 No. 4 No. F Suppy/Extract Grilles 4-way ceiling/roof mounted air extract/supply grille with an airflow rate of 0.1m 3 /s and size 450x450mm. To be as as "Myson" fixed blade louvers or approved equivalent. 24 No G Insulated 20SWG ductwork for mechanical ventilation 376 SM H Volume control damper for 300x300mm duct 12 No. I J Perforated cable/pipe tray of size 450x150mm complete with supports and covering Allow for associated electrical works including but not limited to individual cold cabinet machine isolators and cables to interconnect the evaporator and outdoor unit approximately 15 meters apart. 120 Lm K Allow for factory inspection for two engineers and one client representative to the country of the manufacture of the mortuary cold cabinets including travelling, food, accommondation and communcation expenses. L Training of the client staff on the operation and maintenance Total for Carried Forward to Collection Page Q 14

16 COLLECTION PAGE FOR MORTUARY COLD CAINETS INSTALLATION Item Description 1 Total carried forward from page 1 2 Total carried forward from page 2 Total Cost for Mortuary Cold Cabinets Carried to Summary Page Q 25 Q 15

17 Item Description Qty Unit Rate Cost Kitchen Extract System Supply, deliver, install, test and commission the following equipment/ items as described. Where trade names are mentioned the tenderer must provide the same materials as other brands shall not be accepted without a written authority to supply alternative brands by the Mechanical Engineer. Ductwork A 500 x 500mm extract duct from hood to fan, constructed from 18 S.W.G. rolled galvanized steel sheet and connected to the fan by flexible connections and flanged joints. All joints and seams shall be sealed with mastic to make them airtight. 45 SM External Weather Louvre for Kitchen Duct 1000mm x 1000mm external weather louvers with a weather resistant external cover for fresh air inlet openings complete with galvanized coated wire mesh screen on the front face and frame and blades fabricated from extruded aluminium sections. As TROX or equal and approved. 1 No. C KItchen Extract Hood 3800 x 2800 x 600mm deep kitchen extract hood manufactured from 16 SWG anodized Aluminium sheet complete with its framework, supports and stiffened by a frame of 38 x 38mm galvanized mild steel R.H.S. The hood shall have a 75mm wide by 25mm deep grease drainage channel all round with 20mm diameter drain holes and a plenum box. 1 No D E F Grease Filter ank The grease filter unit consisting of a double angle bank housing with top exit for use in island canopy applications for housing 16No. 508 x 508mm top exit washable type stainless steel filter panels. The unit shall have removable grease trays and framework made out of stainless steel. As "Vokes" double sided V-bank housing with top exit or equal and approved. Grease Filter The grease filters of size 508 x 508mm washable type stainless steel filter panels. The unit shall have removable grease trays and framework made out of stainless steel. The filter shall be composed of folded woven metal material interspersed with layers of expanded metal mesh of stainless steel and shall be capable of filtering a total of 1020m 3 /hr. The filter panels shall be easily removable for washing as and when necessary. As "Vokes" or equal and approved. Vapor Proof Light Fitting Vapor proof light fittings, capacity 65 watts in a heat resistant and watertight enclosure all complete with in approved heat resistant conduits and wiring in the kitchen hood. 1 No 12 No 2 No Total Carried Forward to Collection Page Q 16

18 Item Description Qty Unit Rate Cost A Extract Fan Inline axial fan capable of extracting 1.5m 3 /s of air against 250Pa static pressure. The fan will run at a maximum speed of 1200 revolutions per minute and be driven by an electric motor. The fan shall be installed complete with roof cowl, plenum box and adaptor, base support with acoustic upstand, duct flange, sealing frame, inlet and bird guards and isolators in accordance with the manufacturer s printed instructions. To be as brand S&P model or equal and approved. 1 No C D Fan Installation Allow for fixing of fan, sealing and water proofing of the exit area of duct through the roof. Anti-vibrations Mounting Anti-vibrations mounting to isolate vibrations between the fan and the roof structure shall be able to withstand a load range of upto 57Kg per mounting and shall be as WOODS part No or equal and approved. Fan Control Panel Splash proof control panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter, overload relay and overheat safety control and fuses. 1 No 1 No E Associated Electrical Work Electrical works including but not limited to wiring and conduits to both kitchen extract fans and control panels from local isolators provided by others. It shall include a push and turn safety switch near the fan for isolation during servicing and maintenance. Total Carried Forward to Collection Page Q 17

19 COLLECTION PAGE FOR KITCHEN EXTRACT WORKS Item Description 1 Total carried forward from page 1 2 Total carried forward from page 2 Total for Kitchen Extract Works Carried Forward to Summary Page Q 25 Q 18

20 Item Description Qty Unit Rate Cost A C GROUND FLOOR MECHANICAL VENTILATION Supply, deliver, install, test and commission the following equipment/ items as described. Where trade names are mentioned the tenderer must provide the same materials as other brands shall not be accepted without a written authority to supply alternative brands by the Mechanical Engineer. Ductwork SWG 22 Galvanized mild steel ductwork complete with bends, transformation pieces, branch takeoffs, flanges and stiffeners all as per the approved working drawings. The ducts shall be used in first floor. Extract Fan Silenced extract box fan unit of duty 0.75 m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. Control Panel Splash proof controlled panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter overload relay and overheat safety control and fuses. 350 SM 9 No. 9 No. Associated electrical D Associated electrical works for the above installations Damper E Volume control damper of 250x300mm ductwork 8 No. F Fire damper of 250x300mm ductwork 4 No. G H I J Extract Grilles 200 x 200mm register with volume control damper as manufactured by Trox Technik or approved equivalent. Flexible Duct 200mm diameter flexible duct manufactured from aluminium foil complete with connectors, stiffeners, supports, etc all as per the approved working drawings. The ducts shall be used in lower ground and ground floors. External Louvre All weather air extract louver complete with volume control dampers of size 400 x 400 mm Door Grilles Door lourve grille to be mounted on the door. The grille to be made of corrosion resistant material and minimm dimensions to be 400x400mm.The grille should be capable of discharging atleast 5m3/hr. It shall be as Xpelair or equal and approved. 42 No. 120 No. 7 No. 24 No. Total Carried Forward to Collection Page Q 19

21 Item Description Qty Unit Rate A Extract Fans for Rooms Wall mounted extract fan capable of atleast 670m 3 /hr and having sound pressure level of not more than 50dba at 3 meters. It shall be complete with front cover,on/off switch,long length ladder strips exterior productive grille, wall kit, panel fixing clips, internal lourve grille and back drought shutter. The fan will be flush mounted into the wall. It shall be as Xpelair GX9 or approved equivalent. 0 No. C D Darkroom Extract Fan Dark room wall mounted extract fan capable of at least 670m 3 /hr and having sound pressure level less than 50dba at 3 meters. It shall be complete with front cover, on/off switch, long length ladder strips exterior productive grille, wall kit, panel fixing clips, internal lourve grille, dark room cowls and back drought shutter. The fan will be flush mounted into the wall. It shall be as Xpelair GX9 or approved equivalent. Radiology Extract Fan Radiology room wall mounted extract fan capable of at least 670m 3 /hr and having sound pressure level less than 50dba at 3 meters. It shall be complete with front cover, on/off switch, long length ladder strips exterior productive grille, wall kit, panel fixing clips, internal lourve grille, dark room cowls and back drought shutter. The fan will be flush mounted into the wall. It shall be as Xpelair GX9 or approved equivalent. Split Silencer Fan silencer constructed from rolled pre-galvanized sheet steel with spun rings incorporating tapped insets for fixing. Absorbent material shall be acoustic grade minimal fibre with an erosion resistant facing the silencer to be suitable for 381mm diameter. The installed in the supply duct and fan to be as "Woods" type or equal and approved. 1 No 1 No 7 No E F G As-built Drawings Maintenance and Operation Manuals Allow for as-built drawing, maintenance and operation manuals in both soft and hard copies. Three copies of the as-built drawing shall be submitted in A1 paper in a scale of 1:50 System alancing The systems shall be balanced such that the spaces shall be balanced as per the designed flowrates indicated in the drawings. It will be the onus of the tenderer to make sure that the flows are adjusted to meet these requirements. Duct Painting Allow for painting (2 No coats) of the ductwork with suitable matt paint to match the walls where the duct is exposed. Total Carried Forward to Collection Page Q 20

22 Item Description Qty Unit Rate A C MORTUARY RECEIVING EXTRACT SYSTEM Ductwork SWG 20 Galvanized mild steel ductwork complete with bends, transformation pieces, branch takeoffs, flanges and stiffeners all as per the approved working drawings. The ducts shall be used in first floor. Extract Fan Silenced extract box fan unit of duty 0.5 m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. Control Panel Splash proof controlled panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter overload relay and overheat safety control and fuses. 60 SM 3 No. 3 No. Associated electrical D Associated electrical works for the above installations Damper E Volume control damper of 250x300mm ductwork 6 No. F Fire damper of 250x300mm ductwork 3 No. G H I J Extract Grilles 200 x 200mm register with volume control damper as manufactured by Trox Technik or approved equivalent. Flexible Duct 200mm diameter flexible duct manufactured from aluminium foil complete with connectors, stiffeners, supports, etc all as per the approved working drawings. The ducts shall be used in lower ground and ground floors. External Louvre All weather air extract louver complete with volume control dampers of size 400 x 400 mm Door Grilles Door lourve grille to be mounted on the door. The grille to be made of corrosion resistant material and minimm dimensions to be 400x400mm.The grille should be capable of discharging atleast 5m 3 /hr. It shall be as Xpelair or equal and approved. 24 No. 48 No. 3 No. 4 No. K Split Silencer Fan silencer constructed from rolled pre-galvanized sheet steel with spun rings incorporating tapped insets for fixing. Absorbent material shall be acoustic grade minimal fibre with an erosion resistant facing the silencer to be suitable for 381mm diameter. The installed in the supply duct and fan to be as "Woods" type or equal and approved. Total Carried Forward to Collection Page 3 No. Q 21

23 Item Description Qty Unit Rate A FIRST FLOOR MECHANICAL VENTILATION Ductwork SWG 22 Galvanized mild steel ductwork complete with bends, transformation pieces, branch takeoffs, flanges and stiffeners all as per the approved working drawings. The ducts shall be used in first floor. Extract Fan Silenced extract box fan unit of duty 0.5 m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. 80 SM 5 No. C Control Panel Splash proof controlled panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter overload relay and overheat safety control and fuses. 5 No. Associated Electrical D Associated electrical works for the above installations Damper E Volume control damper of 250x300mm ductwork 10 No. F Fire damper of 250x300mm ductwork 5 No. G H I J Extract Grilles 200 x 200mm register with volume control damper as manufactured by Trox Technik or approved equivalent. Flexible Duct 100mm diameter flexible duct manufactured from aluminium foil complete with connectors, stiffeners, supports, etc all as per the approved working drawings. The ducts shall be used in lower ground and ground floors. External Louvre All weather air extract louver complete with volume control dampers of size 400 x 400 mm Door Grilles Door lourve grille to be mounted on the door. The grille to be made of corrosion resistant material and minimm dimensions to be 400x400mm.The grille should be capable of discharging atleast 5m3/hr. It shall be as Xpelair or equal and approved. 15 No. 54 No. 5 No. 5 No. Total Carried Forward to Collection Page Q 22

24 Item Description Qty Unit Rate A TOILET EXTRACT Ductwork SWG 22 Galvanized mild steel ductwork complete with bends, transformation pieces, branch takeoffs, flanges and stiffeners all as per the approved working drawings. The ducts shall be used in first floor. Extract Fan Silenced extract box fan unit of duty 0.5 m 3 /s against 150pa External static pressure consisting of a low speed forward curved centrifugal fan housed in galvanised and painted steel casing.the unit shall be suitable for outdoor installation and provided with V.C.D, cowl, and access doors. It shall be as SYSTEMAIR of U.K or approved equivalent with approved anti vibration mountings. 450 SM 14 No. C Control Panel Splash proof controlled panel manufactured from 1.2mm thick sheet with stove enamel finish and clear perplex front cover. The panel shall incorporate isolator contactor phase failure relay, motor starter overload relay and overheat safety control and fuses. 14 No. Associated electrical D Associated electrical works for the above installations Damper E Volume control damper of 250x300mm ductwork 20 No. F Fire damper of 250x300mm ductwork 5 No. G H I J Extract Grilles 200 x 200mm register with volume control damper as manufactured by Trox Technik or approved equivalent. Flexible Duct 100mm diameter flexible duct manufactured from aluminium foil complete with connectors, stiffeners, supports, etc all as per the approved working drawings. The ducts shall be used in lower ground and ground floors. External Louvre All weather air extract louver complete with volume control dampers of size 400 x 400 mm Door Grilles Door lourve grille to be mounted on the door. The grille to be made of corrosion resistant material and minimm dimensions to be 400x400mm.The grille should be capable of discharging atleast 5m3/hr. It shall be as Xpelair or equal and approved. 60 No. 96 No. 14 No. 15 No. Total Carried Forward to Collection Page Q 23

25 Item COLLECTION PAGE FOR MECHANICAL VENTILATION INSTALLATION Description 1 Total carried forward from page 1 2 Total carried forward from page 2 3 Total carried forward from page 3 4 Total carried forward from page 4 5 Total carried forward from page 5 Total Cost for Mechanical Ventilation Works Carried to Summary Page Q 25 Q 24

26 SUMMARY PAGE - AIR CONDITIONING AND MECHANICAL VENTILATION WORKS Item Description Total Cost 1 Total for Preliminaries and General Items. 2 Total Carried Forward from Collection Page for Air Conditioning Works (Q 5). 3 Total Carried Forward from Collection Page for Fume Cabinets (Q 6). 4 Total Carried Forward from Collection Page for Freezer (Q 9). 5 Total Carried Forward from Collection Page for Coldroom (Q 12). 6 Total Carried Forward from Collection Page for Mortuary Coldrooms (Q 15). 7 Total Carried Forward from Collection Page for Kitchen Extract System (Q 18). 8 Total Carried Forward from Collection Page for Mechanical Ventilation (Q 24). Total for Air Conditioning and Mechanical Ventilation Works Carried to Form of Tender in words Tenderer's Name and Stamp..... Address Period To Execute The Works Telephone No.... Mobile Phone No Tenderer s V.A.T No... Tenderer s P.I.N No Tenderer's Signature Date.... Witness Signature... Date... Q 25

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 WATER-SOURCE UNITARY HEAT PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Direct Fired Heater Model AD Specification

Direct Fired Heater Model AD Specification Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems. 15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution

More information

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013 SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited 1 more than just a fan supplier The most diverse range of industrial fans & accessories available from a single source... 2 products oem & industrial 3 single inlet centrifugal backward curved centrifugal

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

CENTRAL SPLIT UNIT UNIC

CENTRAL SPLIT UNIT UNIC CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

AIR COOLED PACKAGED CHILLER

AIR COOLED PACKAGED CHILLER AIR COOLED PACKAGED CHILLER UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its

More information

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE Hi-Pres Self Contained A/C Unit TYPE SCU-C & SCU-W Product specifications HI-PRES MARINE & OFFSHORE Contents Introduction..................... 2 Type SCU-W.......................... 2 Type SCU-C...........................

More information

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS. Installation Guide This information is provided as a guide and may differ from project to project. It is assumed that the property is a two storey dwelling. Obviously a bungalow represents a simpler task,

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

PART M PLUMBING FOR SANITARY FITTINGS AND INTERNAL DRAINAGE Item Description Qty Unit Rate Kshs

PART M PLUMBING FOR SANITARY FITTINGS AND INTERNAL DRAINAGE Item Description Qty Unit Rate Kshs PART M PLUMBING FOR SANITARY FITTINGS AND INTERNAL DRAINAGE Item Description Qty Unit Rate Kshs Supply, deliver, install and commission the following sanitary appliances complete with all accessories including

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

KITCHEN EXTRACTORS K Series

KITCHEN EXTRACTORS K Series KITCHEN EXTRACTORS K Series CK-4F CK-5 CK-6F Description Construction The K Series range of centrifugal extractors are specifically designed for the extraction of moist, grease laden air and fumes from

More information

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser. SECTION 23 37 00 - AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers 3. Grilles. PART 2 - PRODUCTS 2.1 ROUND CEILING DIFFUSERS B. Product Description:

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning. 1 3 2 4 5 Closed Circuit Cooling Tower Factory Assembled - Modular Compact Design 1 IP56 Motor(s) directly coupled to low energy and high efficient fan(s) 2 Fibreglass reinforced polyester (FRP) sandwich

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK KITCHEN EXTRACTORS K Series CK-25 N CK-35 N CK-6 F Range of centrifugal extractors specifically designed for the extraction of moist, grease laden air and fume from under domestic cooker canopies. This

More information

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS SECTION 23 62 13 - AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H MINI BENCH TOP CHAMBER MODEL: MI-80-A-H Introduction: The Mini Bench top chambers are compact sized humidity chambers which can be placed on a work bench or on the optional stand provided. These chambers

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit) 1. Ninth Floor Dual split DX-Air conditioning unit : a) Outdoor Unit i) For meeting room on ninth floor/ou-01/ - Cooling capacity = 13 Kw 1.1 Supply, fix, test and commision ductable Indoor units (auto

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM SECTION 23 81 06 - PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. This Section includes equipment types that contain all the components of the refrigeration process within

More information

Centrifugal Fans, Non-Overloading, Backward Inclined

Centrifugal Fans, Non-Overloading, Backward Inclined BACKWARD INCLINED CENTRIFUGAL FANS Centrifugal Fans, Non-Overloading, Backward Inclined MVA, MVZ, MVX & MVW Series with laminar blades MAVA, MAVZ & MAVX Series with aerofoil blades Features The combination

More information

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts Small Air Handling units SAM W i d e d u t y r a n g e 0.05m 3 /sec to 2.4m 3 /sec Powerful yet quiet Extensive options VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU) AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory

More information

TOSHIBA AIR CONDITIONING

TOSHIBA AIR CONDITIONING Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS S FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS VAYHAN AIR CONTROLS PVT. LTD. G-1, Park View Residency, Patwari Enclave Gandhi Nagar (IDPL), Hyderabad 500 037. INDIA Phone: +91-40-2372

More information

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components. Page 238126-1 SECTION 238126 - This Section includes requirements for the LEED Rating System. However, equipment specified in this Section may not qualify for LEED Rating System prerequisites and credits.

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TENDER DOCUMENT NIT No.: DLI/C&E/WI-675/290 FOR Tender for Design, Engineering, Supply, installation, testing and commissioning of PACKAGE AIR CONDITIONING (PAC) SYSTEM AND ASSOCIATED WORKS for the project

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

DOCUMENT TABLE OF CONTENTS

DOCUMENT TABLE OF CONTENTS DOCUMENT 00003 June 16, 2005 TABLE OF CONTENTS DOCUMENT NO. INTRODUCTORY INFORMATION DOCUMENT 00003 TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS SECTION 01011 SECTION 01025 SSP21.1-1 SECTION 01026

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd 1 MJC Mini Cartridge Filters Owners Manual TSOM 556 Date of Issue: 13.07.04 Orgreave Drive, Sheffield South Yorkshire. S13 9NR Tel:0114 254 0600 Fax: 0114 2540250 Email:sales@hodgeclemco.co.uk www.hodgeclemco.co.uk

More information

Centrifugal, tank pump designed to remove condensate water from air conditioners, refrigeration equipment, gas boilers and de-humidifiers. Engineered with contractor input and Little Giant quality, the

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: T2HA, T3HA, and T4HA with CAHB Systems Limited Range Multi-Zone Heat Pumps Rev. 1.1 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: ERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED

More information

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data Ducted Three Phase Split System Air Conditioner ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 23 81 26 SPLIT-SYSTEM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

More information

DIVISION 15 MECHANICAL

DIVISION 15 MECHANICAL DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with

More information

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS 0 ICE AIR LLC HARTFORD AVENUE, MOUNT VERNON, NY 10553 WEBSITE: http://www.ice-air.com TEL: (914) 668-4700; FAX: (914)668-5643 Draw1 REV. - 117/133 SENS HEAT RATIO, % TOTAL COOL CAP; % 120 110 COOLING CAPACITY

More information

Canning Shed/Facility Equipment Specifications

Canning Shed/Facility Equipment Specifications Canning Shed/Facility Equipment Specifications Item Qty Description 1 1 ea WALK IN COOLER Fast Trak Indoor One Compartment Walk In, 8' x 8' x 7' 7" H, compartments, cooler with smooth aluminum interior

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SECTION (15833) - HVAC POWER VENTILATORS

SECTION (15833) - HVAC POWER VENTILATORS PART 1 GENERAL 1.01 SUMMARY SECTION 23 34 23 (15833) - HVAC POWER VENTILATORS A. Section Includes: 1. Centrifugal Roof Ventilators. 2. Up-blast Roof Exhaust Fans (Kitchen Hood Exhaust). 3. Ceiling-Mounted

More information

CABINET PARTS For Model: KSSS48QJX00 (Stainless Steel)

CABINET PARTS For Model: KSSS48QJX00 (Stainless Steel) CABINET PARTS 48" BUILT IN REFRIGERATOR 10 02 Litho In U.S.A. (mek) 1 Part No. 1 LITERATURE PARTS LIT2209249 Use & Care Guide LIT2006651 Energy Label LIT2006748 Service & Wiring Sheet LIT628370 Modular

More information

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators

More information

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON 7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products

More information

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS) 1 Panel, Back (Galvanized) M/05039SP M/05034SP M/05034SP 2 Door, Front Top 02976SP 02937SP 02937SP 3 4 Door, Front Bottom w/slots, Damper 1,2 (shown) M/06753-XXSP M/06752-XXSP

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 237413 - PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, outdoor, central-station air-handling units (rooftop units) with the

More information

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N KITCHEN EXTRACTORS CK Series Plastic range Centrifugal extractors manufactured from flame retardant plastic V. All extractors are class II insulation fitted with centrifugal impeller and single phase 23V-5Hz

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

SECTION COOLING TOWERS

SECTION COOLING TOWERS SECTION 23 65 00 COOLING TOWERS PART 1 - GENERAL 1.1 DESCRIPTION A. Packaged, induced draft open circuit cooling tower complete with fill, fan, inlet louvers and associated accessories and equipment. 1.2

More information

CABINET PARTS REFRIGERATOR

CABINET PARTS REFRIGERATOR CABINET PARTS REFRIGERATOR 1 94 Litho In U.S.A. 1 Part No. CABINET PARTS 2 2152011 Front Roller (2) 3 489393 Screw, 4 981122 Roller (Rear) (2) 5 488454 Screw 6 2155013 Clip, Grille 7 489242 Screw 9 836196

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information