Controls for fan coil units and cassettes
|
|
- Douglas Curtis
- 5 years ago
- Views:
Transcription
1 for Fan Coils. Technical Catalogue. for fan coil units and cassettes Stand alone or Modbus communication Built-in, wall-mounted and IR remote Power supply 230V 2 pipes and 4 pipes system Electrical heating Stand alone, selection guide Motor Location Control Standard ECM Fan speed Valves Electrical season mode Built-in Wall mounted Manual Automatic Cooling heating heating manual automatic QZAZ QZAZ QZAZ QZAZ QZAZ QZAZ QZAZ QZAZ With Modbus communication, selection guide Motor Location Control Standard ECM Fan speed Valves Electrical season mode Wall mounted IR remote Manual Automatic Cooling heating heating manual automatic QZAZ QZAZ-10 QZAZ QZAZ-12 QZAZ QZAZ-10 QZAZ QZAZ-12 QZAZ QZAZ-10 QZAZ QZAZ-12 Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
2 for Fan Coils. Technical Catalogue. Stand alone version with standard motor, technical data Built-in controls for fan coil units with decorative cabinet QZBF, QZBT and QZBM Control equipment is delivered separately and not mounted on the unit. Three speed selector switch QZAZ Manual control of fan operation, no thermostatic control 3 speed, switch Integrated thermostat with manual speed control QZAZ Room temperature control, cooling and heating (4 pipes or electrical heating), manual control of fan operation C 20 3 speed, switch Summer/Winter, switch Electronic room thermostat for fan or valves control(on/off), dep. on wiring Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter. Integrated thermostat with auto speed control QZAZ Change over sensor QZAZ Room temperature control, cooling and heating (4 pipes or electrical automatic or manual selector of fan operation) Manual or automatic 3 speeds fan control, switch. Manual (switch) or automatic switching of season mode (Summer/Winter), setting by jumper inside the unit. Automatic for 2 pipes installations with change-over sensor fitted on the water pipe, QZAZ Automatic for 4 pipes installation and continuous chilled and hot water supply, in accordance to the room temperature (-1,6 C = Winter, +1,6 C = Summer, Neutral Zone 3,2 C). Electronic room thermostat for fan and valves control(on/off). It allows to control the chilled water valve (ON-OFF) and the heating electric resistance only in case that the coil is not fed with warm water in winter.. Automatic summer/winter switch to be installed in contact with the water circuit. For 2-tube installations only (not to be used with 2 way valve). Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
3 for Fan Coils. Technical Catalogue. Stand alone version with standard motor, technical data Wall mounted controls for fan coil units - QZBA, ductable units QZSR / QZHR, and cassettes QFDK / QZCC Three speed selector switch QZAZ Manual control of fan operation, no thermostatic control 3 speed, switch Integrated thermostat with manual speed control QZAZ Room temperature control, cooling and heating (4 pipes or electrical) Manual control of fan operation 20 C 3 speed, switch Manual (switch) or automatic switching of season mode (Summer/Winter), setting by jumper inside the unit. Automatic for 2 pipes installations with change-over sensor fitted on the water pipe, QZAZ Electronic room thermostat for fan or valves control(on/off), dep. on wiring Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter. Room thermostat with auto speed control QZAZ Room temperature control, cooling and heating (4 pipes or electrical automatic or manual control of fan operation) AUTO 20 C Manual or automatic 3 speeds fan control switch. Manual (switch) or automatic switching of season mode (Summer/Winter), setting by jumper inside the unit. Automatic for 2 pipes installations with change-over sensor fitted on the water pipe, QZAZ Automatic for 4 pipes installation and continuous chilled and hot water supply, in accordance to the room temperature (-1 C = Winter, +1 C = Summer, Neutral Zone 2 C). Electronic room thermostat for fan or valves control(on/off), dep. on wiring Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter. Master/slave applications QZAZ Printboard for Master/Slave applications, intended for QZB Speed switch (Slave): it allows to control up to 8 units with only one centralized thermostat (1 speed switch for each unit). For controls QZAZ and QZAZ only. QZAZ Printboard for Master/Slave applications, intended for QZB, QSZR and QZCC Speed switch (Slave): it allows to control up to 8 units with only one centralized thermostat (1 speed switch for each unit). For controls QZAZ and QZAZ only. QZAZ Printboard for Master/Slave applications, intended for QFDK Speed switch (Slave): it allows to control up to 8 units with only one centralized thermostat (1 speed switch for each unit). For controls QZAZ and QZAZ only. Note! The Master/Slave printboard is delivered separately and not mounted on the unit. Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
4 for Fan Coils. Technical Catalogue. Stand alone version with ECM motor, technical data Built-in controls for fan coil units with decorative cabinet QZBF, QZBT and QZBM Integrated thermostat with auto speed control QZAZ Room temperature control, cooling and heating (4 pipes or electrical automatic or manual control of fan operation) Manual 3 speed or automatic continuous speed control, switch. Continuous speed control based on the difference between ambient temperature and Set temperature (speed switch in Auto position). Manual Summer/Winter switch Electronic room thermostat for fan or valves control(on/off) Simultaneous thermostatic control of the valves and fan. Wall mounted controls for fan coil units - QZBA, ductable units QZSR, and cassettes QFDK / QZCC Room thermostat with auto speed control QZAZ The control must always be connected with QZAZ power unit (fitted on the unit) or with QZAZ power unit (not fitted on the unit). Room temperature control, cooling and heating (4 pipes or electrical automatic or manual of fan operation) Manual 3 speed or automatic continuous speed control, switch Continuous speed control based on the difference between ambient temperature and Set temperature (speed switch in Auto position). Manual (switch) or automatic switching of season mode (Summer/Winter), setting by DIP inside the unit. Automatic for 2 pipes installations with change-over sensor fitted on the water pipe, QZAZ Automatic for 4 pipes installation and continuous chilled and hot water supply, in accordance to the room temperature (-1 C = Winter, +1 C = Summer, Neutral Zone 2 C). Electronic room thermostat for fan or valves control(on/off) Simultaneous thermostatic control of the valves and fan. Power unit to be installed on the fan coil (fan coil interface). It controls the fan and the valves of the fan coil. The power unit is connected to the electric supply. The power unit receives the information required from the control. It is used with the room thermostat QZAZ Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
5 for Fan Coils. Technical Catalogue. With modbus communication, standard motor and ECM motor, technical data For fan coil units - QZB, ductable units QZSR / QZHR, and cassettes QFDK / QZCC The power electronic board is set to carry out different functions and adjustment modes, in order to meet the installation requirements. The communication protocol is the Modbus RTU-RS 485. These modes are selected by setting the configuration dip switches on the board: 2/4 pipe system. Fan ON/OFF thermostatic control. Valve ON/OFF thermostatic control and continuous ventilation. Valve and simultaneous ventilation ON/OFF thermostatic control. Fan operation control depending on the coil temperature (cut-out probe fitted), which can be activated only in heating mode or heating and cooling mode. Automatic switch of the operating mode by means of water probe QZAZ (optional) applied on the 2 pipe system. Seasonal switch by means of remote contact. ON/OFF of the fan coil by means of the remote contact (window or clock contact). Electric heater control By activating the cut-out probe function, the fan is stopped in winter when the coil temperature is lower than 32 C and started when the temperature reaches 36 C. In summer mode, the fan stops when the temperature inside the coil exceeds 22 C and starts when it drops below 18 C. The following connections are located on the power board: Receiver for infra-red remote control (QZAZ or QZAZ-05-94). QZAZ wall mounted control. RS 485 serial connection to manage several fan coils in Master/Slave configuration (it requires the router QZAZ-50-15) or to create a supervisory network (Modbus). The power electronic board is mounted as standard in the cassette QFDK and is available also for ECM motor. - QZB, QZSR, QZCC - QZHR Standard motor ECM motor Mounted unit Not mounted unit Mounted unit Not mounted unit QZAZ QZAZ QZAZ QZAZ Size 1 to 6, standard motor Size 7, standard motor Mounted unit Not mounted unit Mounted unit Not mounted unit QZAZ QZAZ QZAZ QZAZ Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
6 for Fan Coils. Technical Catalogue. With modbus communication, technical data Wall mounted room controller QZAZ Wall control with display that allows controlling one or more units in Master/Slave mode. The control is equipped with internal sensor to detect the room temperature, which can be defined as a priority compared to the return air sensor on the fan coil. The QZAZ control features the following functions: Switch the appliance ON and OFF. Temperature set. Modify the set point (when used as a +/- 3 variation of the set point configured from Modbus communication). Set the fan speed (low, medium, high or auto fan). Set the operation mode (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). Time setting. Weekly ON/OFF program. Display and change of the fan coil operation parameters. A group of units with power electronic control board can be connected via a serial link and can consequently be managed at the same time by just one QZAZ wall control. It requires a router QZAZ to manage the communication between master and slave(s). By cons the group of units can t be connected to a BMS though the Modbus communication. Using the special jumper present on the board, one unit must be configured as the master, and all the others as slaves. It is clear that the remote control must be pointed at the receiver on the master unit. To avoid problems, it is recommended to install and connect the receiver only on the master unit. One control for each unit (MAXIMUM LENGTH OF THE CONNECTION CABLE = 20 m) One control for more units (20 units max.) (MAXIMUM TOTAL LENGTH OF THE CONNECTION CABLE = 800 m) Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
7 for Fan Coils. Technical Catalogue. Infra red remote control QZAZ The infra-red remote control QZAZ allows setting by a remote position the fan coil operation parameters. It integrates the following functions: Switch the appliance ON and OFF. Temperature set. Set the fan speed (low, medium, high or auto fan). Set the operation mode (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). Time setting. 24 hours ON/OFF program. An IR receiver must be mounted on the outlet air diffuser and connected to the power control board QZAZ-10/12 Application/Control operations: Clock 24 hours 00:00 am pm Timer: the program switches the divice on and off Displays the temperature set point Fan speed setting: 3 speeds plus automatic selection Operating mode: heat/cool/fan only plus automatic mode selection STARTSTOP TIMER CLOCKSET SET TEMP C A A Not mounted IR receiver Mounted IR receiver Product QZAZ QZAZ QZB, QZSR, QZHR, QZCC, QFDK with metal grille QZAZ QZAZ QFDK with ABS grille One control for each unit One control for more units (20 units max.) (MAXIMUM TOTAL LENGTH OF THE CONNECTION CABLE = 800 m) Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
8 for Fan Coils. Technical Catalogue. Multifunction control QZAZ Another option available for the serial communication between the units is the possibility to connect up to 60 units in series and manage them with just one wall mounted QZAZ controller. The wall mounted controller can be used to set the operating mode for each individual unit connected, display the operating conditions of each individual unit, and set the ON/OFF time sets for each day of the week (the program can be set for all the units and for a maximum of two groups of units). If more than 60 units need to be connected, two or more controllers must be used. Each wall mounted controller only manages the units it is connected to. The QZAZ control is used to manage a series of fan coils, up to a maximum of 60 units (the maximum length of the RS 485 connection cable must not exceed 800 m), from one single control point. The QZAZ control communicates via a serial line with all the units connected, with the possibility of controlling them all together or individually. In fact, the unique address of each individual fan coil means that all the units can be called at the same time, or the individual unit called, to perform the following functions: display the current operating mode, the fan speed, the set point; display the room temperature measured on the individual unit; turn all the units ON and OFF at the same time or alternatively each unit individually; change the operating mode (fan only, heating, cooling, automatic changeover); change the set point; modify the values and operation parameters of the fan speed. Each function can then be sent to all the units connected, or alternatively to each individual unit. Different set points or operating modes can be set for each individual unit. The QZAZ panel can also be used for the time management of the units over the week. Four ON times and four OFF times can be set on the units for each day of the week. A different Temperature set that will be considered as Operation set for all connected appliances, can be set for each event. If the Temperature set is not entered for the individual event, it must be set during programming for each individual unit or for the entire network. s without receiver or with receiver can be connected within the network: the former can receive instructions only from the QZAZ wall mounted panel; while the latter can receive information from both the wall mounted panel (QZAZ-05-96) and infra-red remote control. Use the infra-red remote control to force ON mode of the individual unit, if ON/OFF daily time programming has been set. The unit will regain the settings from the QZAZ panel during execution of successive start-up program. Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
9 for Fan Coils. Technical Catalogue. Change over sensor QZAZ The QZAZ sensor can be combined with MB boards to be placed on the water supply pipe upstream 3 way valves (not to be used with 2 way valve). The QZAZ sensor must be used as described below: Change-Over for 2-pipe system for the automatic switch of the operating mode. If water temperature is lower than 20 C, cooling mode is set; on the other hand, if water temperature exceeds 30 C, heating mode is set. It can be used on units with electric heater and hot water supply. The T2 priority probe activates the electric heater or water valve, depending on the water temperature detected. If water temperature exceeds 34 C, the water valve ON-OFF control is activated; on the other hand, if water temperature is lower than 30 C, the electric heater is activated. Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
10 for Fan Coils. Technical Catalogue. Ordering examples with products codes list Fan coil unit with decorative cabinet, with automatic control of fan speed QZB(F or M or T)-aa-bb-c-1 QZB(F or M or T)-aa-bb-c-5 QZAZ QZAZ Fan coil unit without decorative cabinet, cassette or ductable unit with automatic control of fan speed QZBA-aa-bb-c-1 QFDK-aa-0-c-d-1 + QFDZ-aa-bb QZCC-aa-b-c-1 QZSR-aa-b-c-1 QZHR-aa-b-c-1 QZBA-aa-bb-c-5 QFDK-aa-0-c-d-5 + QFDZ-aa-bb QZCC-aa-b-c-5 QZSR-aa-b-c-5 QZAZ QZAZ (QZAZ or QZAZ-12-21) Fan coil unit without decorative cabinet, ductable unit or Coanda unit with automatic control of fan speed, master/ slave application Master unit: QZBA-aa-bb-c-1 QZSR-aa-b-c-1 QZCC-aa-b-c-1 Slaves unit (up to 8): QZBA-aa-bb-c-1 QZSR-aa-b-c-1 QZCC-aa-b-c-1 QZAZ QZAZ Cassette with automatic control of fan speed, master/slave application Fan coil unit with high pressure, control with IR remote control, Stand-alone or Modbus communication available QZHR-6a-b-c-1 QZAZ-10-(30 or 31) + QZAZ QZAZ-05-(91 or 92) QZHR-7a-b-c-1 QZAZ-10-(40 or 41) + QZAZ QZAZ-05-(91 or 92) Cassette with ABS grille, control with IR remote control, stand-alone or Modbus communication available QFDK-aa-1-c-d-1 + QFDZ-15-bb QZAZ-10-(20 or21) + QZAZ QZAZ-05-(93 or 94) QFDK-aa-2-c-d-5 + QFDZ-15-bb QZAZ-12-(20 or21) + QZAZ QZAZ-05-(93 or 94) Fan coil unit, ductable unit or cassette, Modbus communication and room controller QZB(A,F,M or T)-aa-bb-c-1 QFDK-aa-1-c-d-1 + QFDZ-aa-bb QZCC-aa-b-c-1 QZSR-aa-b-c-1 QZB(A,F,M or T)-aa-bb-c-5 QFDK-aa-2-c-d-5 + QFDZ-aa-bb QZCC-aa-b-c-5 QZSR-aa-b-c-5 QZAZ-10-(20 or21) + QZAZ QZAZ-12-(20 or21) + QZAZ Fan coil unit with high pressure, Modbus communication and room controller QZHR-6a-b-c-1 QZHR-7a-b-c-1 QZAZ-10-(30 or 31) + QZAZ QZAZ-10-(40 or 41) + QZAZ Master unit: QFDK-aa-0-c-d-1 + QFDZ-aa-bb Slaves unit (up to 8): QFDK-aa-0-c-d-1 + QFDZ-aa-bb QZAZ QZAZ Fan coil unit with decorative cabinet, with automatic control of fan speed, master/slave application Master unit: QZB(F or M or T)-aa-bb-c-1 Slaves unit(up to 8): QZB(F or M or T)-aa-bb-c-1 QZAZ QZAZ Fan coil unit, ductable unit or cassette with metal grille, control with IR remote control, Stand-alone or Modbus communication available QZB(A,F,M or T)-aa-bb-c-1 QZAZ-10-(20 or21) + QZAZ QZAZ-05-(91 or 92) QFDK-aa-1-c-d-1 + QFDZ-10-bb QZCC-aa-b-c-1 QZSR-aa-b-c-1 QZB(A,F,M or T)-aa-bb-c-5 QZAZ-12-(20 or21) + QZAZ QZAZ-05-(91 or 92) QFDK-aa-2-c-d-5 + QFDZ-10-bb QZCC-aa-b-c-5 QZSR-aa-b-c-5 Fläkt Woods 9416 GB Specifications are subject of alteration without further notice.
Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationQZB "Standard" comfort fan coil
Key features Vertical or horizontal installation Concealed installation or with decorative cabinet Cooling ( pipes) and heating ( pipes or electrical heating) ECM version for low energy consumption The
More informationQFDK "ägir II" chilled water cassette
Key features Chilled water cassette Cooling ( pipes) and heating (4 pipes or electrical heating) ECM version for low energy consumption Beautiful design, six different sizes, high control flexibility,
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationNEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units
NEW MB control board for Modbus communication protocol Compliant with ERP 0 Regulation (EU) No. 7/0 Quality management systems ISO 900 Cert. n 0/ www.eurovent-certification.com www.certiflash.com Air Conditioning
More informationFan Coil Range HYDRONIC TERMINALS
Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing
More informationa-life Hydronic terminals Fan-coil for professional applications, with cabinet or built-in version 1,50-7,50 kw <<< BACK INDEX
More information
QZHW Fan Coil Unit. Key features. Specifications
Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More informationNEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationNEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT
NEW energy consumption ECM motors Air Conditioning ECM Cassette Fan Coil Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationUniTrane Ductable Units D-line and B-Line
UniTrane Ductable Units D-line and B-Line Discover the new UniTrane Ductable Units The ideal air-conditioning solutions for your building Air-conditioning plays an important role in the comfort level in
More informationYFCN Fan Coil Unit centrifugal fan
YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 0.7 kw to 7.4 kw Wired controls JWC-3V Remote three speeds controller JWC-T JWC-3V + Electronic thermostat and Summer/Winter switch
More informationconsumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK
NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationNEW. communication protocol. Control board with Modbus. Air Conditioning SkyStar SkyStar ECM Cassette Fan Coil Units
NEW Control board with Modbus communication protocol Air Conditioning ECM Cassette Fan Coil Units Quality management systems ISO 9001 Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com MD-600
More informationECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)
york air-conditioning products ECM Technology Running costs. Energy consumption. Life cycle. These are 3 issues that are becoming more and more important in the choice of Fan Coil Units. With these criteria
More informationApplication guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E
Application guide ARMONIA ARMONIA EC 1,3-11 kw Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E TABLE OF CONTENTS APPLICATION GUIDE Ref : ARMONIA-AGU-1010-E ARMONIA Introduction
More informationUser manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort
User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE
More informationSkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor
SkyStar SK Cassette Fan Coil Unit with Asynchronous Motor Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result
More informationCRIMSON & CRIMSON MAX
High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial
More informationSkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board
SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic
More informationTechnical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil
MDL SOLUTIONS Technical Catalogue NA Version PDWL AECM LSTAT Series Hydronic EC Ducted Fan Coil Hydronic Fan Coil Platform Introduction Company Introduction HVAC Solutions Sonkor Global MDL SOLUTIONS Technical
More informationEVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled
EVF818 Split execution controller for temperaturecontrolled blast chillers (with capacitive touch-key user interface, which can be integrated into the unit) ENGLISH INSTALLER MANUAL ver. 1.0 CODE 144F818E104
More informationSapphire Series TSVW & TWWS Chillwater Digital Thermostats
Sapphire Series TSVW & TWWS Chillwater Digital Thermostats Table of Contents 1. Introduction 3 TSVW Main Components 3 TWWS Main Components 4 2. Display Panels for TSVW and TWWS Thermostats 4 TSVW Display
More informationCONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3
CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3 KEYBOARD...3 ACTIVE KEY COMBINATIONS...4 TURNING THE UNIT ON/OFF...4 CHANGING TEMPERATURE AND FAN
More informationETN1000/MIGA - Operating manual
o C ETN1000/MIGA - Operating manual Cool Heat Fan Hi Med Lo SET ON OFF AUX Auto Fan 1. Switching the unit ON/OFF On/Off Mode Fan Press the ON/OFF button to activate or deactivate the thermostat - ON or
More informationManual for the integration in BMS/GTC
Manual for the integration in BMS/GTC Communication parameters MODBUS RTU and BACNET COMMUNICATION UTBS PRO-REG Software Version 3.6 EN ÍNDEX 1. GENERALITIES...2 1.1. Introduction...2 1.2. signals types...2
More informationTechnicians Manual Single Compressor
Technicians Manual Single Compressor HAC-FF-D WALL PAD Operating Manual Version PCB Version V2.3.5 Version wall pad Version Manual Page 1 Contents 1. Main features 2. Main technical data 3. Wall pad 4.
More informationPlease read this manual carefully before installation and use.
Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions
More informationHYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?
HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS? New condensed air water chillers using scroll compressors and capacities from 21 to 217 kw Models 801-1501 Models 1601-6002 Models
More informationGeneral information. Technical data...2 General information...2. Description. Installation
user manual Table of contents Technical data Technical data...2 General information...2 Installation...3 Navigation...3 First run...4 Main screen...6 Main menu...6 Time...7 Date...7 Calendar...7 Language...10
More informationECL Comfort 300 / V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 / 301 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 / 301 is an electronic temperature controller which can be loaded with selected applications by means of an ECL
More informationControl System Structure
Control System Structure Centralized Controller Wireless Controller Centralized Controller Wired Controller BMS User Friendly Management Control Solution Integrated Management Building Management Convenient
More informationINDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM
Y : PUHY R2 : PURY WY : PQHY WR2: PQRY S : PUMY INDOOR UNIT PLFY-VAM VCM PCFY-VGM PLFY-VLMD PKFY-VAM VGM VFM PMFY-VBM PFFY-VKM PEFY-VMS PFFY-VLRM VLEM PEFY-VMR Fresh Air Intake type PEFY-VML VMM VMH LONWORKS
More informationREMOTE CONTROL FOR CHILLER MYCHILLER
REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN
More informationLCF Touch Modbus Datasheet Application Security Advice Caution
LCF Touch Modbus Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet Subject to technical alteration Issue date: 3.11.214 Application Modern design flush mounting fan coil room
More informationEVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815
EVF815 Split execution controller for temperature-controlled blast chillers (with capacitive touch-key user interface, which can be integrated into the unit) ENGLISH INSTALLER MANUAL ver. 2.0 CODE 144F815E204
More informationCOMFORT HYDRONIC TERMINALS
COMFORT HYDRONIC TERMINALS i i-chd NEW GENERATION CASSETTE WITH EC HIGH EFFICIENCY MOTOR. CENTRIFUGAL FAN WITH CONTINUOUS AIR FLOW REGULATION AND SPEED MODULATION. ENERGY CONSUMPTION REDUCED BY MORE THAN
More informationENERGY TOP. Condensing boiler solutions
ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for
More informationLennox Climatic 50 and BMS Modbus, Trend or BACnet.
Lennox Climatic 50 and BMS Modbus, Trend or BACnet. Specification of the Bus: Type: RS485 Speed: (Adjustable on Climatic 50 via display ; Setting 3933) 1200 2400 4800 9600 19200 Parity: Fixed no parity
More informationTemperature - Humidity - Pressure
TEMPERATURE-HUMIDITY-PRESSURE INDICATORS XA100C Configurable digital indicators for temperature, humidity or pressure C: 32x74mm DC- TBXABDA100 XA100C -0C0PU PTC NTC inputs 12V DC- TBXABCA100 XA100C -0C0TU
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-036 08/11 FEATURES > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) > 3 x 0-10V outputs
More informationFingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk
Fingertip control, optimum efficiency, total comfort and clear reporting warmafloor.co.uk 1 Contents Intelligent control. 3 The key to efficiency Key system features 4 and benefits 7 Touchscreen 5 Alarms
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationECL Comfort V a.c. and 24 V a.c.
Data sheet ECL Comfort 300 230 V a.c. and 24 V a.c. Application The ECL Comfort 300 is an electronic temperature controller which can be loaded with selected applications by means of an ECL Card. The ECL
More informationETN-24-SUPER-PROG (US Program - Celsius)
Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions
More informationNEW RANGE OF WARM AIR CURTAINS
NEW RANGE OF WARM AIR CURTAINS stay connected and informed in real time www.france-air.com CONTENTS SELECTION GUIDE 3 HARMONY ONE EVO Compact single-phase warm air curtain 4 REGULATION 5 HARMONY Visible
More informationETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings
ETNC-FC-BAC-PIR- Rev. Index Operating instructions....- Turning the thermostat and OFF Selecting temperature scale Adjusting the Set point temperature (for set point and set points configurations) Selecting
More informationXLH210: controller for gas leak detectors
pag. 1 / 7 XLH210: controller for gas leak detectors Dixell introduces the new digital controllers designed to be combined with 4 20mA gas leak detectors. XLH210 is a microprocessor based controller, designed
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationOJ Waterline control system
OJ Waterline control system THERMOSTATS FOR COMFORT HEATING AND SNOW MELTING Product presentation Mk3 It s all about Room Temperature Control! The essential main goals are: Comfort Flexibility Reliability
More informationOPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A
OPERATION MANUAL Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A EKHBH007A*** EKHBX007A*** Indoor unit for air to water heat pump
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationNatural Ventilation Controller with 24vDC drive NVC-1204
Natural Ventilation Controller with 24vDC drive NVC-1204 BACnet Enabled C-038 08/16 FEATURES SPECIFICATION > 24V DC supply > Native BACnet communications > Master/Slave grouping (shared information) >
More informationQ-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17
Q-SMART MODBUS KIT Modbus Protocol & Parameters Cod.001085120EN rev.a ed.08/2018 Q-SMART Software Version AE17 Index 1 Modbus Protocol on Q-SMART... 4 1.1 Broadcasting... 4 1.2 Data Protection... 4 1.3
More informationCLIMAV 2.0 Thermoregulation Systems
Thermoregulation Systems EN 2 TIEMME, INNOVATION FOR A STEADY GROWTH Tiemme Raccorderie is an international leader in the production and marketing of plumbing and heating components. Experience, innovative
More informationOPERATION MANUAL. Packaged air-cooled water chillers and packaged reversible air to water heatpumps EWAQ009ACV3 EWAQ010ACV3 EWAQ011ACV3
OPERATION MANUAL Packaged air-cooled water chillers and packaged reversible air to EWAQ009ACV3 EWAQ010ACV3 EWAQ011ACV3 EWYQ009ACV3 EWYQ010ACV3 EWYQ011ACV3 EWAQ009ACW1 EWAQ011ACW1 EWAQ013ACW1 EWYQ009ACW1
More informationPanasonic RAC/PAC Training
New 2014 Range of RAC & PACi with VRF & A2W overview Panasonic RAC/PAC Training We are your Panasonic air conditioning Specialists! Panasonic Products Range Overview RAC Room Air Conditioners PACi TTQ
More informationPLC / HMI Modbus (Slave) Addressing
Made in the USA PLC / HMI Modbus (Slave) Addressing Legacy - HMI touch screen with built in Legacy - Pentra PLC with Expandable I/O Legacy Chiller Systems, Inc. General Information IMPORTANT READ BEFORE
More informationN M AirControl AHU. Control manual
N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4
More informationAir Conditioning Carisma CRS High Pressure Fan Coil Units.
Air Conditioning Carisma CRS High Pressure Fan Coil Units Quality management systems ISO 900 Cert. n 0/ www.euroventcertification.com www.certiflash.com INTRODUCTION In line with innovative trends and
More informationTOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and
More informationCH130ARR-CH130ARFR. Room thermostats for fan-coils, 3 speeds + automatic KIT THERMOSTAT ACTUATOR FAN CONNECTION COLOUR CODE CODE CODE SPEED TYPE
CH130ARR-CH130ARFR CH130ARR-CH130ARFR Room thermostats for fan-coils, 3 speeds + automatic CH130A model is a fan-coil 4- or 2-pipe thermostat that allows you to control the ambient temperature both in
More informationThe Sabiana. of Fan Coil
The Sabiana family of Fan Coil Range Basics A complete range of fan coils for use with Hot water for heating and chilled water for cooling Eurovent Certified Typical Applications Schools Hotels Commercial
More informationTechnical Manual Binair Monobloc Heat Pump
Technical Manual Binair Monobloc Heat Pump MODEL BINAIR12 Introduction Disassembly of the machine must be carried out by any professional or any special agency assigned by us. All operation and maintenance
More informationPoolsmart Plus Touchscreen Heating Controller. Installation & Operating Manual
Poolsmart Plus Touchscreen Heating Controller Installation & Operating Manual Important Notes Congratulations on purchasing the PoolSmart Plus touchscreen heating controller, manufactured in England to
More informationC&H NORDIC Commercial 4 SERVICE MANUAL
C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.
ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data. The RVA63 controller can be utilized to control the following system configurations via LPB communication. Equipment Required
More informationOne Product Numerous Applications Electronic Controllers for Heating, Cooling, Ventilation and Air Condition
MAKING MODERN LIVING POSSIBLE One Product Numerous Applications Electronic ontrollers for Heating, ooling, Ventilation and Air ondition Electronic ontrollers from Danfoss: Only a Few Products for an Endless
More informationCWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT
TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12
More informationRoom thermostats for fan-coils, 3 speeds + automatic
CH130ARR-CH130ARFR Room thermostats for fan-coils, 3 speeds + automatic CH130A model is a fan-coil 4- or 2-pipe thermostat that allows you to control the ambient temperature both in the heating and cooling
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More informationDew point set DS 400
set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the
More informationA36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS
SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers
More informationNEW GREEN TECHNOLOGY
NEW GREEN TECHNOLOGY - suitable for all heating systems Magnetic Boiler installed in all fan coils - no need for external devices! A c t i v e G r e e n S w e d e n A B ACTI VE Operation limits This technology
More informationiq Star LYRA II chilled beam cassette
iq Star LYRA II chilled beam cassette Key features Ventilation Heating and cooling Compact chilled beam Adjustable induction Flow Pattern Control Integrated control In option: Demand Controlled Ventilation,
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationTouch Screen Room Thermostat with Modbus Communication
Touch Screen Room Thermostat with Modbus Communication 50-020 Wrocław www.el-piast.com 1 / 8 Contents 1. Product Introduction.... 3 2. Technical Data..... 3 3. LCD Display... 3 4. Operation Instruction.
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationCatalogue 2015 AHU N Range: VENTUS VS 10 - VS 650
Catalogue 2015 01 VTS GROUP 1.1 VTS: Manufacturer No. 1 in the world 1.2 3 constituents of success 02 2.1 Water heaters 2.2 Product range 2.3 Technical parameters 2.4 Destratificator VR-D 03 CONTROLS
More information1/8. Field settings table. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P C
1/8 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P353731-1C - 213.12 2/8 3/8 User settings Preset values Room temperature 7.4.1.1 Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More information1.0 Digital Controller
Form CP-AHU D19_D21_D22 (11-17) D303072-A Obsoletes Forms CP-Preeva-D21 (1-16) Doc No 303072, CP-Preeva-D19 (1-16) Doc No 303071 Applies to: Preeva, MAPS, MAPS II, RPB, RPBL & SSCBL Series For Air Handler
More informationMaster devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems
X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone
More informationECOELEGANT SERIES INSTALLATION OPERATION AND SERVICE MANUAL (AMERICAS VERSION) HW~ECM SERIES
ECOELEGANT SERIES INSTALLATION OPERATION AND SERVICE MANUAL (AMERICAS VERSION) HW~ECM SERIES Revised: July 11, 2016 Page 1 of 57 INVESTING IN QUALITY, RELIABILITY & PERFORMANCE. ISO 9001 QUALITY World
More informationApplica. First Edition uly 2005
McQuay y Smart t Manager er Chilled Water System Applica pplication Manual First Edition Jul uly 2005 Introduction Introduction... Introduction-1 Section 1: Networ ork k Interface Module (NIM) and Netwar
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More information1/8. Field settings table [6.8.2] =... ID66F3. Applicable indoor units *HYHBH05AAV3 *HYHBH08AAV3 *HYHBX08AAV3. Notes - 4P E
/8 [6.8.2] =... ID66F3 Applicable indoor units *HYHBH5AAV3 *HYHBH8AAV3 *HYHBX8AAV3 Notes - 4P35373-E - 27.2 2/8 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step:
More informationand Channel indicator and monitoring unit B Operating Instructions 2.00/
and Channel indicator and monitoring unit B 70.0202 Operating Instructions 2.00/00375947 Contents 1 Instrument functions... 3 1.1 Ordering details... 3 1.2 Functions of the LMD-96... 4 1.3 Functions of
More information1.0 Digital Controller
1.0 Digital Controller...1 1.1 Display Function Keys...1 1.2 Thermostat Display...2 1.3 Controller hardware input output points... 4 2.0 Sequence of Operation...5 2.1 States of Operation...5 2.2 Modes
More informationInstallation, Start-Up, and Operating Instructions
Installation, Start-Up, and Operating Instructions CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...1 INSTALLATION...1-5 Install Batteries...1 Select Transmitter Location (Optional)...1 Mount Transmitter
More informationMiniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)
PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics
More informationElectronic Pellet Burner Controller NPBC-V3-1
Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationI/O ZONE 560/583 USERS GUIDE
I/O ZONE 560/583 USERS GUIDE 641-224 641-242 641-237 1 Table of Contents Hot Gas Re-Heat Valve On/Off:... 15 THE ZONE CONTROLLER...4 Modulating Re-Heat Valve:... 16 SPECIFICATIONS...5 CONTROLLER COMPONENTS...6
More informationField settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8
/8 [6.8.2] =... ID66F2 Applicable units *BLQ5CAV3 *DLQ5CAV3 *BLQ7CAV3 *DLQ7CAV3 Notes (*) *B* (*2) *D* 2/8 User settings Preset values Room temperature 7.4.. Comfort (heating) R/W [3-7]~[3-6], step: A.3.2.4
More information