Cleaning System. Amajet. Type Series Booklet
|
|
- Mary Newman
- 5 years ago
- Views:
Transcription
1 Amajet Type Series Booklet
2 Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal
3 Contents Contents Waste Water Amajet...4 Main applications... 4 Fluids handled... 4 Operating data...4 Designation... 4 Design details... 4 Configuration and function... 5 Amajet system for cleaning tanks... 5 SewerAmajet system for cleaning storage sewers... 5 Product benefits... 5 Example of operating costs per cleaning process... 6 Selection information... 6 Amajet system for cleaning tanks... 6 SewerAmajet system for cleaning storage sewers... 6 Programme overview / selection tables...8 Overview of product features... 8 Material variants... 9 Technical data Dimensions Amajet H - Horizontal installation Amajet S - Compact installation Amajet VX - Vertical installation...13 General assembly drawings with list of components Amajet H...14 Amajet S Amajet VX SewerAmajet H SewerAmajet S...18 SewerAmajet VX
4 Waste Water Amajet Designation Example: Amajet H / 11 4 X G Key to the designation Code Description Amajet Type series H Installation type H Horizontal installation S Compact installation VX Vertical installation with guide wire and suspension arrangement 100 Nominal discharge nozzle diameter [mm] 260 Impeller diameter [mm] 11 Motor size 5, 7, 11, 16 4 Number of poles X Motor version U Non-explosionproof X Explosion-proof to ATEX II 2G T3 G Material variant G Standard design, main components made of grey cast iron G1 Like G, with impeller made of duplex stainless steel G2 Like G, with impeller made of white cast iron GH Like G, with impeller and intermediate casing made of white cast iron Main applications The Amajet system can be employed wherever tanks and storage sewers require cost-efficient cleaning. The Amajet system is perfect for automatic cleaning of walls and floors in: Stormwater retention tanks, stormwater overflow basins and stormwater settling basins Storage sewers in sewer systems Fluids handled Water Stormwater Waste water Mixed water Operating data Operating properties Characteristic Value Sizes DN 100 Motor rating P to 16 kw Fluid temperature t Up to +40 C 1) Design details Design Drive Stationary or compact pump set with horizontally or vertically installed submersible motor propulsive jet pump with non-clogging F impeller Three-phase asynchronous motor DOL starting Enclosure: IP68 (permanently submerged) to EN / IEC 529 Thermal class F Motors integrated in explosion-proof pump sets are supplied in Ex d IIB type of protection. Shaft seal Two bi-directional mechanical seals in tandem arrangement, with liquid reservoir Impeller type F impeller Free-flow impeller (impeller type F) Suitable for the following fluids: fluids containing solids and stringy material as well as fluids with entrapped air or gas F impellers are suitable for handling the following fluids: Activated sludge Digested sludge 1) Higher fluid temperatures on request. 4 Amajet
5 Heating sludge Mixed water Raw waste water Raw sludge Recirculated sludge Bearings Grease-packed rolling element bearings Configuration and function Amajet system for cleaning tanks Design KSB's system solution consists of: A robust submersible motor propulsive jet pump with nonclogging free-flow impeller An Amajet ejector set designed for high cleaning performance A control unit, optionally with operating data logging system and data storage unit Level monitoring equipment Control unit Function Amajet sucks in the fluid from near the tank floor and transports it to the ejector nozzle. The narrow passage through the reducing nozzle increases the flow velocity in and downstream of the nozzle, producing a low pressure in the mixing chamber compared to the fluid surrounding it and compared to the atmosphere. Through the vent line this low pressure draws in air, which is mixed with the fluid in the mixing chamber. The fluid-air mixture is ejected through the ejection pipe as a high-velocity jet that is horizontal to the tank floor. The combined effects of the water jet and the small air bubbles in the fluid generate a powerful horizontal flow with a large vertical reach in the tank. The turbulences caused in the entire tank by both transverse and longitudinal flows lift up the solids and keep them suspended. During drainage the sludge is carried out of the tank at an even rate to prevent peak demand periods for biological waste water purification. If the fill level in the tank exceeds 1 metre, the energy-saving intermittent operation mode set to approximately 10 to 50 % of the operating time is sufficient. This mode is designed for cleaning tank walls and posts. At a fill level below approximately 1 metre, the general cleaning mode (i.e. continuous operation) is activated. A control unit with operating data logging system and data storage unit Function SewerAmajet is installed on the sewer floor in the storage area. By means of a suction pipe and ejector it mixes waste water with air and ejects the mixture lengthwise along the bottom of the sewer, thus enriching the waste water with oxygen and preventing digestion. The high-grade cleaning effect of this patented cleaning equipment is achieved by combining a throttle valve with a jet nozzle. The control unit of the storage sewers transmits the required impulses for opening and closing the throttle valve at set intervals. When the valve is partly closed, the pressure increases up to 1.5 times during continuous operation of the pump set. When the valve opens, this energy is suddenly released and produces shock waves, which spread over the entire length of the storage sewer. SewerAmajet for storage sewers can usually be retrofitted without any structural modifications as long as a suitable shaft structure is available for installing SewerAmajet. A single SewerAmajet system can also be used to clean several sewers arranged in parallel, provided that specific conditions are met. Control unit The control unit is precisely set to match the conditions in storage sewer systems and ensures a fully automatic operation of the pump set, taking into account the storage sewer geometry, inflow and discharge conditions as well as the pollution load. Product benefits Energy-saving cleaning mode by intermittent operation matching the actual hydraulic conditions Intelligent control system and perfect automation by process controller: Electronic control units select a matching operating mode for each water level; operating times are computed based on the current water level. Low maintenance Low life cycle costs thanks to low maintenance costs and high energy efficiency Straightforward assembly of ready-made components Control system Optimum operation of the Amajets is provided by KSB's electronic control unit. The parameters for all levels and hystereses needed for automatic operation can be freely set to satisfy all system requirements. Amajet only operates when the water level within the tank decreases, i.e. during the draining process. The operating times for the individual Amajets are calculated separately based on the current water levels. SewerAmajet system for cleaning storage sewers Design KSB's system solution consists of: A robust submersible motor propulsive jet pump with nonclogging free-flow impeller A SewerAmajet ejector set with throttle valve Amajet 5
6 Example of operating costs per cleaning process Pump set: 1 Amajet H /7 4 X G Flow rate of the drainage pump: Q = 72 m 3 /h Tank size: 20 x 8 m Fill level: 3.5 m Electricity costs (assumed): 0.25 /kwh Total tank volume: V T = 560 m 3 Water volume in continuous operation: V C = 160 m 3 Water volume in intermittent operation: V I = 400 m 3 Drainage times (without inflow): 1. In continuous operation: 2. In intermittent operation (at operating time set to 30 %): Operating time of the Amajet: Electricity costs: t D = t I = 160 m 3 72 m 3 /h 400 m3 72 m 3 /h = 2,2 h 0,3 = 1,6 h t M = 2.2 h h = 3.8 h K En = 9.8 kw x 3.8 h x 0.25 /kwh K En = 9.31 Selection information Amajet system for cleaning tanks For a pre-selection of Amajet pump sets and ideal tank shapes please contact your KSB AG sales representative. The reference values given are based on optimum conditions. As project-specific conditions such as fluid composition, internal structures, surfaces, drainage, etc. can have a significant impact we recommend involving us already in the planning phase. SewerAmajet system for cleaning storage sewers Rough reference values for the cleaning capacity per pump set Maximum cleaning reach depending on the floor gradient Floor gradient Max. cleaning reach per pump set 2) [ ] [m] ) These values are practically only achieved in ideal conditions; floors, rough surfaces and unfavourable sewer geometries may reduce the cleaning capacity. 6 Amajet
7 Shaft structure dimensions [mm] Amajet 7
8 Programme overview / selection tables Overview of product features Overview of product features Feature Material variants G G1 G2 GH Number of motor poles 4-pole 5 4, 7 4, 11 4, 16 4 Motor Explosion protection, version U Not explosion-proof Explosion protection, version X ATEX II 2G T3 Starting method DOL 3) Voltage 400 V 4) Cooling By surrounding fluid Power cable Length 15 m 5) Cable entry Absolutely watertight Type Rubber-sheathed cable, see table "Overview of power cables" Bearings Grease-packed rolling element bearings sealed for life Sealing elements Elastomer seals Nitrile butadiene rubber NBR 6) Shaft seal Bellows-type mechanical seal 7) Monitoring equipment Winding temperature Temperature switch (bimetal) in the winding, plus PTC for explosion protection Leakage in the motor space 8) Coating Environmentally friendly KSB standard coating, colour RAL ) Max. ambient temperature 40 C Max. fluid temperature 40 C Acceptance tests Hydraulic system 10) General To ISO ) Overview of power cables Feature S1BN8-F rubber-sheathed cable S07RC4N8-F rubber-sheathed cable TEHSITE Tefzel cable Design Standard Optional Optional Rated voltage 1000 V 750 V 750 V EMC screening - - Insulation material EPR 12) EPR 12) ETFE 13) Max. continuous temperature of insulation 90 C 90 C 135 C For permanent immersion in waste water to DIN VDE /HD ) Star-delta starting is an option at 400 V 4) Optional: 500 V, 690 V 5) Optional: up to 50 m 6) Optional: Viton = fluorocarbon rubber FPM 7) Optional: mechanical seal with covered spring 8) Optional: leakage sensor 9) Optional: 250 µm two-component epoxy coating 10) On request only 11) Optional: with test report EN ) EPR = ethylene propylene rubber 13) ETFE = ethylene tetrafluoroethylene 8 Amajet
9 Material variants Overview of material variants Component Material variants G G1 G2 GH Pump set Pump casing EN-GJL-250 Impeller EN-GJL Intermediate casing/discharge cover EN-GJL Mechanical seal (pump end) SiC / SiC Mechanical seal (drive end) Carbon / SiC Shaft Bearing bracket EN-GJL-250 Motor housing EN-GJL-250 Elastomer seals NBR 14) Screws/bolts A4 (corresponds to ) Installation parts Claw (for installation type VX) EN-GJL-250 Bracket (for installation type VX) Guide wire suspension bracket (for installation type VX) Guide wire (for installation type V/X) Support foot (for installation type Galvanised steel 15) V/X) Suction elbow and discharge elbow Galvanised steel 15) Ejector set Galvanised steel 15) Ejector set, mixing chamber EN-GJL-250 Vent line Galvanised steel 15) Connection pipe (for installation type Galvanised steel 15) H) Other connecting pipes Galvanised steel 15) 14) Nitrile rubber (Perbunan) 15) Optional: Amajet 9
10 Technical data Technical data for standard operation Pump size Ejector set Rated power Hydraulic power Flow rate Head Nozzle Diffusor P 2 P Hydraulic Q H [mm] [mm] [kw] [kw] [l/s] [metres of water] / ,5 4,0 23 5, / ,5 5,5 32 7, / ,5 7,5 40 7, / ,8 11, , / ,0 13, , / ,0 14, ,0 Technical data for shock wave operation Pump size Ejector set Rated power Hydraulic power Flow rate Head Nozzle Diffusor P 2 P Hydraulic Q H [mm] [mm] [kw] [kw] [l/s] [metres of water] / ,8 7,5 40 7, / ,0 11, , / ,0 13, ,5 Motor data Explosion-proof and non-explosionproof designs: motor data for 400 V, 50 Hz, 3-phase Motor type Rated power P 2 Power input P 1 Rated current I N Power factor cos φ Starting method Starting current I A, DOL 16) Enclosure to DIN Power cable Outside diameter of the cable [kw] [kw] [A] [A] [mm] 5 4 XG 5,5 6,7 12,1 0,80 DOL/YΔ 56 IP 68 H07RN-F12G1.5 17,0-19,0 7 4 XG 7,5 8,86 15,8 0,81 DOL/YΔ 80 IP 68 H07RN-F12G1.5 17,0-19, XG 11,8 13,4 23,5 0,82 DOL/YΔ 132 IP 68 H07RN-F12G1.5 17,0-19, XG 16,0 17,9 33,0 0,79 DOL/YΔ 200 IP 68 H07RN- F7G4+5x1.5 26,9-28,8 16) See Motor Data Booklet Amajet
11 Dimensions Amajet H - Horizontal installation Amajet H 1) Floor suction pipe 2) Connection pipe 3) Max. fluid level 4) Vent DN 65 5) Supporting angle, adjustable 6) Locking pins (Ø 10 mm, depth 30 mm) Weights Size [kg] H / H / H / H / Amajet 11
12 Amajet S - Compact installation 1) 3) 2) 4) 73 w 205 h 1 h 2 d 6) 5) c Amajet S 1) Cable tie 2) Max. fluid level 3) Vent DN 65 4) Inspection hole 5) Locking pins (Ø 10 mm, depth 30 mm) 6) Supporting angle, adjustable Dimensions [mm] Size c d h 1 h 2 w [kg] S / S / S / S / Amajet
13 Amajet VX - Vertical installation Ø 10 A 60 A B ) 165 Ø 5 1) a 700 a) b 1 3) B O a) N a) 62 Z a) d 220 Ø 14 4) Z 120 Amajet VX 1) Normal fluid level 2) Max. fluid level 3) Vent DN 65 4) Foundation bolts Ø 14 Dimensions [mm] Size a b 1 d N min O min [kg] S / S / S / S / DN 2 z f x l f g f K f D f Flange dimensions Flange dimensions [mm] DN 2 g f K f D f z f Ø l f Amajet 13
14 General assembly drawings with list of components Amajet H Amajet H List of components Part No. Description Part No. Description Connection pipe Adjusting strip (part of the ejector set) 139 Suction elbow 705 Vent line Support foot 710 Pipe 14 Amajet
15 Amajet S Amajet S List of components Part No. Description Part No. Description Connection pipe Adjusting strip (part of the ejector set) 139 Suction elbow 705 Vent line 144 Discharge elbow 710 Pipe Support foot Foot plate Amajet 15
16 Amajet VX Z Amajet VX Z List of components Part No. Description Part No. Description Hook 705 Vent line Wire 732 Claw Anchor bolt 894 Mounting bracket 183 Support foot 904 Grub screw Adjusting strip (part of the ejector set) /.37 Nut 571 Bracket 970 Label/plate 572 Guide wire suspension bracket 16 Amajet
17 SewerAmajet H SewerAmajet H List of components Part No. Description Part No. Description Connection pipe Adjusting strip (part of the ejector set) 97-3 Lifting magnet (including holder) 705 Vent line 139 Suction elbow 710 Pipe Support foot 746 Throttle valve Amajet 17
18 SewerAmajet S SewerAmajet S List of components Part No. Description Part No. Description Connection pipe Adjusting strip (part of the ejector set) 97-3 Lifting magnet (including holder) 705 Vent line 139 Suction elbow 710 Pipe 144 Discharge elbow 746 Throttle valve Support foot Foot plate 18 Amajet
19 SewerAmajet VX 97-3 Z SewerAmajet VX Z List of components Part No. Description Part No. Description Hook 705 Vent line Wire 732 Claw Anchor bolt 746 Throttle valve 97-3 Lifting magnet (including holder) 894 Mounting bracket 183 Support foot 904 Grub screw 571 Bracket /37 Nut 572 Guide wire suspension bracket 970 Label/plate Amajet 19
20 KSB Aktiengesellschaft P.O. Box Halle (Saale) Turmstraße Halle (Germany) Tel Fax /05-EN
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet
Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed,
More informationVertical Ring-section Pump WKTB. Type Series Booklet
WKTB Type Series Booklet Legal information/copyright Type Series Booklet WKTB All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for
More informationCalio-Therm S NC/NCV Type Series Booklet
High-efficiency Drinking Water Pump Calio-Therm S NC/NCV Type Series Booklet Legal information/copyright Type Series Booklet Calio-Therm S NC/NCV All rights reserved. The contents provided herein must
More informationSL S.S.N.51D
GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html
More informationUPZ PUMP POWER FOR TOP PERFORMANCE UNDER
Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy
More informationmini-compacta Type Series Booklet
Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationHTM Circulation Pumps acc. to DIN EN 733 Type NKX
HTM Circulation Pumps acc. to DIN EN 733 Type NKX General The new NKX pump line replaces our former heat transfer oil circulation pump type NKL s. The outer dimensions of both pump types are identical
More informationSubmersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges
Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges TM High Performance in Wastewater Pumping HOMA submersible water and wastewater pumps operate worldwide in numerous domestic, municipal
More informationChemical Pumps Vertical Chemical Pump Type TNP
Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis
More informationLifting Plants Product Overview
Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing
More informationSUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L
operating limits Flow up to: m /h Head up to: m w.g. Liquid temperature range: + to 5 C* Specific gravity of liquid:.5 max. ph of liquid: - Max. immersion depth: m Free passage: Ø mm ND of discharge port:
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html
More informationGRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz
GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps
More informationSpecially Designed Waste Water & Sewage Pumps
Specially Designed Waste Water & Sewage Pumps Technical specifications Ebitt SC series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and other
More informationAutomatic Waste Water Lifting Unit
Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins,
More informationCR20-07 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview
More informationGSZ/GSD HIGH VOLUME DEWATERING PUMPS
www.tsurumi-global.com / HIGH VOLUME DEWATERING PUMPS Submersible High Volume Dewatering Pumps Tsurumi and series of submersible heavy-duty pumps deliver high volume discharge. This former consists of
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications
More informationCompany name: Created by: Phone:
Position Qty. Description 1 SL1..1.55..6G.C Product o.: 9655 ote! Product picture may differ from actual product on-self-priming, single-stage, centrifugal pump designed for handling wastewater, process
More informationGRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz
GRUNDFOS DATA BOOKLET Centrifugal machine tool pumps 5/6 Hz Contents General description Introduction 3 Applications 3 Special features 3 Identification Type key Codes Pump types and data Construction
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions
More informationCR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ
GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html
More informationSubmersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet
Submersible Waste Water Pump Ama-Drainer N 301/302/303 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303 All rights reserved. The contents provided herein
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 60527 Pressure Range: Suction Range: 120 to 1013 mbar 200 to 800 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationCR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html
More informationCR64-1 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html
More informationCR32-4 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html
More informationCRN A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html
More informationCAP SERIES SEWAGE AND WASTE WATER PUMPS
Part 8 CAP SERIES SEWAGE AND WASTE WATER PUMPS TECHNICAL SPECIFICATIONS : Turbosan CAP series consists of centrifugal sewage and waste water pumps. They are used for pumping muddy liquids like sewage and
More informationSIHI LPH-X - Liquid Ring Vacuum Pump One Stage
- Liquid Ring Vacuum Pump One Stage LPH 50523 Pressure Range: Suction Range: 120 to 1013 mbar 70 to 500 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with
More informationSubmersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet
Submersible Waste Water Pump Ama-Drainer N 301/302/303/358 Type Series Booklet Legal information/copyright Type Series Booklet Ama-Drainer N 301/302/303/358 All rights reserved. The contents provided herein
More informationInstallation, Operating and Maintenance Instructions
04/2016 Installation, Operating and Maintenance Instructions www.sulzer.com 2 Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Sewage Pump Type ABS XFP PE1 (50 Hz)
More informationEBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU
EBARA Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU water wastewater EBARA International Corporation Standard Pump Division S ubmersible Non-clog Pump Model DLFU DVFU DDLFU Features Watertight
More informationCR A-F-A-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html
More informationFull-line Product Overview
Full-line Product Overview End Suction Centrifugal Pumps This general purpose pump can be configured in frame-mounted and close-coupled, semi-open and enclosed impeller configurations. They are available
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationCRN90-1 A-F-G-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html
More informationVSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.
Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From
More informationBlock Macerators Series ABM-2-S
Block Macerators Series ABM-2-S Usage Macerators chop solids conveyed in liquids; materials like wood, textiles, plastics, paper, rubber, bones, skins, glass etc., so that they may be pumped. After treatment
More informationDLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:
DLKF A. General: Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide
More informationTorqueflow Sydex. Fluid Management. K Range Pumps
Torqueflow Sydex Fluid Management K Range Pumps The extremely popular K-range is a heavy-duty robust industrial pump designed for a wide range of applications throughout a multitude of industries. Available
More informationTechnical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP
Pumped liquids The pump is suitable for clean, non-aggressive water slightly dirty (grey) wastewater. The open-impeller construction ensures the free passage of solids up to 00 mm. Functions -5 Automatic
More informationHOMA Pump, Ansonia Connecticut
TM High Performance in HOMA began as a submersible motor manufacturer more than fifty years ago. We expanded into full pump production in the 1960s. Every product we design and manufacture has always exceeded
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationFlygt Top-Entry Agitators CONVENIENT AND EFFICIENT
Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT INTRODUCTION Top energy-efficient performance Advantages of Flygt top-entry agitators Rising to the mixing challenge All mixing applications require varying
More informationGRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz
GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions
More informationSpandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products
Spandau Pumps Overwiev of Products 1-6000-US Sealless Immersion Pumps for Industrial Applications Centrifugal and screw pumps for low-, medium- and high-pressure applications Quality Management DIN EN
More informationSekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS
Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted
More informationSubmersible and Immersible Pumps
Submersible and Immersible Pumps for sewage & sludges A range of quality pumps featuring the unique Hidrostal Screw Centrifugal Impeller. Models are available for fully, partially submerged or dry installation
More informationFEATURES. Other Fed-Flush Arrangements
Brochure # 0710 TYPE TYPE... VSAF SEWAGE EJECTOR SYSTEM Flows to 600 gpm, Heads to 120, 1 thru 40 HP. Discharge size 4, 1750 and 1150 RPM, strainer in discharge pipe. HIGHLIGHTS Installations where rags
More informationETP Series - Self Priming Pumps
ETP Series - Self Priming Pumps ETP SERIES Decades of experience in development & manufacturing of injection Moulded Polypropylene Corrosion Resistant Pumps. Design philosophy is to design pumps that are
More informationX1 series Submersible Drainage Pump
X1 series Submersible Drainage Pump 50HZ STAIRS INDUSTRIAL CO., LTD. X1 SERIES - Submersible Pump Model code X1-03 M A - 32 Discharge size A =Float switch S =Vertical level switch M = Single Phase T =
More information15-BER3. parts list as Excel-spreadsheet. Tsurumi Europe GmbH
5-BER3 data sheet parts list exploded view dimensional drawing free standing type dimensional drawing TOS-type sectional drawing free standing type sectional drawing TOS-type performance curve parts list
More informationCombi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610
Combi Modular System Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610 SPX FLOW Johnson Pump brand water, chemical and petrochemical standardised pumps represent a range of centrifugal pumps
More informationKTV DEWATERING PUMPS
www.tsurumi-global.com DEWATERING PUMPS Submersible Lightweight Compact Dewatering Pumps Tsurumi -series features submersible pumps of lightweight compact design. The pump body is made of die-casted aluminium
More informationKGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.
Grinder Pumps KGP(X) 7.5-15HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) (PENDING) The KEEN PUMP KGP(X) series centrifugal grinder pumps are designed for municipal, commercial
More informationVRD. Sump pump for polluted liquids
VRD Sump pump for polluted liquids VRD Sump pump for polluted liquids VRD submersible pumps are used for pumping up liquids containing solid particles from a low-lying, fluctuating, liquid level and where
More informationProcess engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system
Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental
More informationSubmersible Grinder Pump Type ABS Piranha S10 - PE125
6006085 EN 04/2018 EN Installation, Operating and Maintenance Instructions www.sulzer.com 2 Installation, Operating and Maintenance Instructions (Original Instructions) Submersible Grinder Pump Type ABS
More informationPORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES
PORTABLE HYDRANT PN1 1A; 2A; 1B; 2B; 1C; 2C TYPES HP 1 page 1A (type 1) (type 2) In water supply systems for fire extinguishing or other necessities. - Design... in conformity with STAS 698; - Nominal
More informationCentrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL
Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL General The DICKOW centrifugal pump, type NCL, is designed for handling liquids in the chemical and petrochemical industry, in refineries,
More informationCombiBloc Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More informationTechnology for life. Unit heater LH
Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables
More informationInstallation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers
Bulletin 1200/4 (Revised 5/12) Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers INNOVATORS IN HEAT TRANSFER I. INSTALLATION OF HEAT EXCHANGERS A. HEAT EXCHANGER SETTINGS 1)
More informationFlygt centrifugal grinder pumps
Flygt centrifugal grinder pumps For heavy-duty shredding applications Introduction Non-clogging grinder pump for tough challenges Why choose a Flygt grinder pump? Provides high efficiency Adjusts to actual
More informationK4RH(X) Solids-Handling Pumps
Solids-Handling Pumps K4RH(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location) RECESSED IMPELLER Handles Stringy and Fibrous Materials Passes Large Solids Pumps Heavier
More informationHD 7/11-4 Cage Classic
HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure
More informationTechnical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm
HEGA Horizontal Multistage Pump Brief Introduction HEGAHorizontal Multistage Pump is the new multistage product series, the excellent hydraulic performance and structure of which have enabled low cost
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationMasters in energy efficiency
KBA Metal Decorating Masters in energy efficiency 2-Piece Ovens The new benchmark in economy and efficiency GB 2-Piece Ovens Optimised drying solutions for 2-piece cans KBA-MetalPrint GmbH KBA-MetalPrint
More informationTransformer oil coolers BETA & CETA
2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil
More informationSSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials
The SSA series is an All-in-One self-priming silent booster pump, the compact design combined pressure tank, pressure switch, flow switch and full protection controller, moreover, the evolutional flow
More informationgrundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate
grundfos SEG AUTOadapt SEG AUTOadapt range The perfect grinder pump for wastewater transport be think innovate Designed for dependability, efficiency and cost-effectiveness AUTOadapt sets new standards
More informationSEWAGE PUMPS WITH CUTTER IMPELLER
www.tsurumiglobal.com C SEWAGE PUMPS WITH CUTTER IMPELLER Submersible Sewage Pumps with Impeller Performance Range Tsurumi Cseries pumps are heavyduty, submersible cutter pumps for sewage and wastewater,
More informationAir. Pressure. Motion. nnnnnnnn
Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page
More informationCentrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA
Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA General The selfpriming multistage DICKOW-centrifugal pump is designed for handling hydrocarbons and other volatile liquids. Applications
More information1. GENERAL INTRODUCTION 2. OPERATING CONDITIONS
1. GENERAL INTRODUCTION OM IE1 series three phase asynchronous motor with cast iron housing. These IE1 motors are for application of petroleum, chemical, metallurgical, cement and paper industries, especially
More informationFAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.
FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS History and Development Since the early part of this century, Fairbanks Nijhuis Pump has set industry standards in innovative
More informationExcellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID
Solids Handling Pumps Excellent Engineering Solutions Recessed Vortex Impeller Pumps CLEAR LIQUID The Vortex Principle The VORTEX technique developed by WEMCO is based on the principle of a whirlpool :
More informationHigh pressure cleaning heads cleanliness all around
High pressure cleaning heads cleanliness all around 2 3 Cleaning at the highest level Perfect internal cleaning of vessels with the URACA TWK system In industries such as the chemical, petrochemical, synthetics,
More informationSelf-priming centrifugal pumps
Self-priming centrifugal pumps TOUGH TECHNOLOGY experience of a lifetime // innovation for tomorrow High and dry with j self-priming centrifugal pumps J pumps are self-priming centrifugal pumps with open
More informationKSB mechanical seals for water and waste water applications
Our technology. Your success. Pumps n Valves n Service KSB mechanical seals for water and waste water applications 02 Introduction Single-source supplier: your partner for pumps, valves and service We
More informationMANUAL Oil Level Sensor
PROCESS AUTOMATION MANUAL Oil Level Sensor KVF-104-PF ISO9001 0102 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products
More informationHennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)
Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) 2013-09-16 Tank Station for Coil and Fan Door Production Item B ITEM NO. DESCRIPTION
More informationReliable Long-Term Solutions For Your Toughest Pump
Reliable Long-Term Solutions For Your Toughest Pump Municipal Raw Sewage Grit Handling Sludge Recirculation Digester Cleaning Thickened Sludge Storm Water Sump Pump (Pipe Gallery) Head Works Industrial
More informationPENGUIN SERIES HSC PUMPS INTRODUCTION
PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal
More informationBuilding Services. KSB Building Services. A Real Welcome Home.
Building Services KSB Building Services. A Real Welcome Home. 2 Introduction Build the future with KSB. Whether you earn your living by installing or selling pumps, valves and systems, or want to make
More informationFlygt N-pumps 3231, 3306, 3312, 3356, 3400
Flygt N-pumps 3231, 3306, 3312, 3356, 3400 The large wastewater pumps that cut operating costs motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48
More informationTYPE POS Oil Shield Sump Pump
Type POS Oil Shield Provides protection for the environment by preventing oil products from entering sewer systems, environmentally Sensitive River and waterways, while protecting equipment and areas from
More informationVogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM
Vogel Pumpen Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed
More informationVUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud
VUD Vac-U-Dry Vacuum Dehydrators The optimized balance between heat, vacuum, process design and an easy, user friendly operating system for removal of water and particulate from hydraulic and high viscosity
More informationSELF-PRIMING JET PUMPS
SS Anti-Rust SS Shaft Copper & Cold-rolled SELF-PRIMING JET PUMPS CONTENTS 1. Applications.... Model Description.... Technical Data... 4. Implementation Standards... 5. Safety Precautions... 6. Product
More informationInline-Pumps Type NCV /NCVL
Inline-Pumps Type NCV /NCVL General DICKOW-Inline-Pumps, series NCV / NCVL, have been developed for the chemical, petrochemical and related industries. Since the pumps are installed inline, only a minimum
More informationBlockpumps. Vogel Series LSB. Lenntech. Tel Fax
Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Blockpumps Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858 Technical Data Performance: m Capacity up to 450m
More information