1 Product portfolio A one-stop-shop for industrial cooling products and developments
2 MORE THAN 50 YEARS OVERSLUIZEN Oversluizen has a rich history spanning more than 50 years of designing and building high-end technical cooling solutions for the industrial, maritime, agricultural and on- and offshore oil & gas applications. Furthermore, we have been developing new products and solutions using a combination of different cooler types, each meeting the specific requirements for combustion engines, hydraulic aggregates, generator sets and aircoolers. Using the whole range of available coolers, Oversluizen can select the optimum solution for every single project. Typically products are e.g. oilcoolers, charge-air coolers, plate-heat-exchangers, dry-coolers, shell-and-tube coolers, expansion tanks and ventilators. Depending per project we combine them side by side or face to face within one frame.
3 Products Air-/water cooled products Jacket water coolers / radiators Intercoolers / charge air coolers Oil coolers Exhaust coolers Condensers Fuel coolers Combination coolers Other products and services Plate-heat exchangers In-house calculation and manufacturing Multi-Wing ventilators calculation and assembling Pressure caps Stainless steel 316 Expansiontanks steel / stainless steel Heat recovery OTE (PID) controller Fan control Trouble shooting and repairs
4 Oversluizen Thermal Engineering product versatility has a solution for each applications. Markets: Industrial Off-shore Agricultural machinery Oil- & gas
5 Industrial air-cooled combi coolers Engineering Manufacturing 3D-design We engineer, manufacture and assemble complete custom made air-cooled coolers that are suitable for a long lifespan meeting heavy duty requirements. Materials such as copper fins, welded tubes and zincore instead of steel frame. In-house coating standards fulfil up to the offshore C5M. The radiators are built in such a way that the cooling block has room for linear expansion.
6 Aluminium oil- & air coolers Our standard product range includes plate and bar coolers for oil- and air, with or without fans. These coolers are applied in pump sets, hydraulic aggregates, generator sets, earthmoving machinery, forklift trucks, tracked vehicles etc. If a standard cooler can t be selected, Oversluizen T.E. designs and manufactures tailor-made units. Oversluizen is officially dealer of the Nissens HP oil cooler range in the Netherlands and Belgium and partner for the Nissens special coolers.
7 Ventilators Industrial environments Oil & Gas industry 24-hour delivery Oversluizen T.E. provides electrically, mechanically and hydraulically powered fans. The electric fans can be provided in 12, 24, 220 and 380 Volt, 50 or 60 Hz fitted with any kind of security on request. The systems are calculated based on maximum circumstances such as load of the engine and the maximum ambient temperature. Oversluizen T.E. has developed a temperature controlled system which can control any pulley, hydraulic or electrical driven fan. Resulting in a ventilator which will not use more power/fuel than necessary to keep the coolant within the needed range. This reduction in mechanical power will also result in a reduction in sound.
8 Airec coolers Charge-air Exhaust Condensing Heat recovery Airec has been founded in 2000 and designed a new high efficient coolers for all industries. The coolers are capable of extracting heat of all sorts of processes, this can be gasses and liquids such as natural gas, biogas, water/glycol, exhaust gasses for combustion engines and compressed air. Due to its small design and high efficiency the coolers can be placed at almost every location. Furthermore condensing moisture out of hot air is also one of the possibilities.
9 Plate heat exchangers In the field of plate heat exchanges Oversluizen Thermal Engineering has a technical collaboration with Alfa Laval. Water/glycol Sea-water Hydraulic oil Condensing Plate coolers of Alfa Laval are suitable for both fluids and gasses and are characterized by their high efficiency. Plate heat exchangers can be tuned to the application in which they will operate, not just due to the dimensions of the plates but also due to the different material types and structures of the plates. By combining several plate types, effective solutions can be provided so that pressure drop and pollution can be reduced to a minimum.
10 OTE (PID)controller Universal fuel- and sound reduction for any type of ventilator as well as electric-, hydraulic or pulley driven applications. Up to 8% fuel saving Sound reduction Universal use The OTE controller is a simple but utmost universal solution for controlling processes using universal signals. A wide range of input and output settings such as: type of sensor, controlling speed and selecting 1 out of three outputs per sensor input. Using the mA inputs and individually setting the PID settings the output can be fully configured.
11 On-site service / monitoring As an extra service, Oversluizen has invested in a wide range of sensors and loggers to troubleshoot or test a specific application. Within our range of sensors we can use a 24 channel data logger, clamp-on flow meters for water, oil or other liquids, pressure sensors and more. First picture (Left to right) Simple temperature sensor (thermocouple) Revolutions counter Flir infrared camera Ultrasonic clamp-on flow meter, Datalogger, with 24 input ports for temperature, pressure sensors.
12 Various products Pressure caps (Stainless steel 316) Mountable filler necks Thermal switches Thermal by-passes Expansiontanks
13 Notes:
14 Interested? If you re interested in our products or if you would like to know whether or not we can make the product that you re looking for, you can contact us by phone or via our website. Address: Mandenmakerstraat NL 2984AS RIDDERKERK Phone number: +31 (0) Website:
Modern Auto Tech Study Guide Chapters 39 & 40 Pages Cooling Systems 43 Points. Automotive Service
Modern Auto Tech Study Guide Chapters 39 & 40 Pages 725 767 Cooling Systems 43 Points 1. The cooling system must control the temperature of the engine for low emissions and maximum efficiency. This will
More informationBrazed plate heat exchangers. For the refrigeration industry
Brazed plate heat exchangers For the refrigeration industry Important components in refrigeration applications Installed for a wide range of duties in refrigeration applications worldwide, Alfa Laval s
More informationChoose the winning team. Heat transfer technology for industrial cooling and air conditioning
Choose the winning team Heat transfer technology for industrial cooling and air conditioning Alfa Laval makes it easy Buying heat exchange components for industrial cooling and air conditioning projects
More informationBrazed Plate Heat Exchanger for CO Applications
Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing
More informationAdvanced heat transfer technology
Advanced heat transfer technology Providing substantial energy savings through customized designs Thermo plate products for the process industry Thermo plate products for the process industry Unique transfer
More informationAdvanced heat transfer technology. Thermo plate products for the process industry. Substantial energy savings through customized designs
www.athco-engineering.dk Thermo plate products for the process industry Substantial energy savings through customized designs Unique transfer characteristics Advanced heat transfer technology ATHCO-Engineering
More informationAlfa Laval spiral heat exchangers
Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance
More informationThe theory behind heat transfer
Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineered solutions. Our equipment, systems and services are dedicated to helping customers to optimize the performance
More informationPENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.
PENDER Vario PENDER Vario Line PENDER Profi Line PENDER Air Curtains PENDER Airquell Exhaust Technology www.pender.de Our company Your manufacturer of trend-setting and efficient hall heating systems Your
More informationGENERAL INFORMATIONS
GENERAL INFORMATIONS Devices only operate in cooling mode. Enviromental-friendly R407c coolant is utilized in standard products. The system can be created with various coolants depending on the water temperature
More informationCooling water/oil heat exchanger with water thermostatic mixer
Cooling water/oil heat exchanger with water thermostatic mixer Four-way water thermostat to control the coolant temperature with built-in heat exchanger. Significantly shortens the warm-up phase of the
More informationMarine Heat Exchangers SALES SERVICE REPAIR
Marine Heat Exchangers SALES SERVICE REPAIR Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PRODUC 104-32 Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL
More informationExchangers. Air-cooled Heat. Exchangers
Hamon Process Heat Exchangers Air-cooled Heat Exchangers Hamon in a few words Hamon D Hondt factories Hamon offices and factories Hamon started its industrial activities in Europe (Belgium and France)
More information02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65
REV. 02 / 01.11.13 COOLING SYSTEM INDE 1. General... 64 2. Specifications... 65 3. Structure and Operation... 65 3.1. Cooling System... 65 3.2. Radiator... 65 3.3. Water Pump... 65 3.4. Thermostat... 65
More informationMECHANICAL SCIENCE Module 2 Heat Exchangers
Department of Energy Fundamentals Handbook MECHANICAL SCIENCE Module 2 Heat Exchangers Heat Exchangers DOE-HDBK-1018/1-93 TABLE OF CONTENTS TABLE OF CONTENTS LIST OF FIGURES... ii LIST OF TABLES... iii
More informationTop performance when the going gets tough
Top performance when the going gets tough The Alfa Laval DuroShell plate-and-shell heat exchanger Sub-headline coming soon DuroShell plate-and-shell made tougher Alfa Laval DuroShell is a specially engineered
More informationAir Conditioning Inspections for Buildings Condensers
. Air Conditioning Inspections for Buildings Condensers PRESENTED BY NIRAJ MISTRY aircon@stroma.com Condensers Condensing Process Three main types: Air Cooled (using ambient air) Water Cooled (using mains,
More informationCZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with
More informationDo not open the cooling system while it is hot or while the engine is running.
Engine And Radiator 2003 Mazda B2300 2.3L Eng VIN D Base Print Date: 1/4/2019 WARNING: Do not open the cooling system while it is hot or while the engine is running. 1. Drain the cooling system. See ENGINE
More informationIncrease efficiency EBIT. pv=nrt. du=dq-dw. Five ways to stay ahead of the competition in the petrochemical industry
Increase efficiency pv=nrt EBIT du=dq-dw Five ways to stay ahead of the competition in the petrochemical industry Boost profitability Five ways to stay ahead of the competition in the petrochemical industry
More informationOWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A
OWNER S MANUAL CPL Evaporative Cooler ILL1456-A (English) (CPL) 2 Introduction 3 Wall Control Functions 7 Drain Valve & Bleed System 8 Maintenance 10 Troubleshooting 1 CPL Evaporative Cooler INTRODUCTION
More informationSB Series Brazed Plate Heat Exchanger Installation Manual
SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual
More informationIN THE MARINE INDUSTRY
H E A T E X C H A N G E R S BULLETIN NO. TIS-108A PRIME SURFACE HEAT EXCHANGERS PLATE & FRAME HEAT EXCHANGERS ALL-WELDED PLATE HEAT EXCHANGERS IN THE MARINE INDUSTRY THE heat transfer people H E A T E
More informationSecure hydraulic system performance. Smart solutions for cooling and cleaning hydraulic oil
Secure hydraulic system performance Smart solutions for cooling and cleaning hydraulic oil The products and the global support you need How can you ensure that your hydraulic systems achieve their full
More informationUNIT 5 COOLING SYSTEMS OF IC ENGINES
UNIT 5 COOLING SYSTEMS OF IC ENGINES Cooling Systems of IC Engines Structure 5.1 Introduction Objectives 5.2 Air Cooling System 5.3 Water Cooling System 5.3.1 Components of Water Cooling System 5.3.2 Advantages
More informationOptimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller
Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ Air cooled chiller Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And today,
More informationMastering the elements
100% Stainless Steel Mastering the elements AlfaNova Fusion-brazed plate heat exchangers AlfaNova Extreme elements extreme technology From the extreme heat of our brazing process comes AlfaNova, the world
More informationRefrigeration Compressed Air Dryer Boreas Variopulse
Refrigeration Compressed Air Dryer Boreas Variopulse The intelligent refrigeration compressed air Why is compressed air processed? Compressed air is an essential form of driving and process energy in all
More informationINDUSTRIAL AIR CURTAIN. IndAC 2
INDUSTRIAL AIR CURTAIN IndAC IndAC industrial air curtain High climate separation efficiency with the IndAC industrial air curtain Optimal climate separation The Biddle IndAC industrial air curtain, is
More informationBrazed heat exchangers
HYGIENIC EQUIPMENT FOR FOOD & LIFE SCIENCES Brazed heat exchangers A product catalogue for refrigeration Refrigeration applications The brazed plate heat exchanger (BHE) is a well-established component
More informationWASTE WATER EVAPORATOR WITH ANY FUEL OPTIONS
WASTE WATER EVAPORATOR WITH ANY FUEL OPTIONS Product: Manufacturer: Engineer: Sales Contact: Technical Contact: Mechanical Contractor: INOV8 Evaporators with INOV8 burners are designed to reduce or eliminate
More informationcooling tailor made Customized OEM cooling units Product range the smart way of cooling!
S W I S S M A D E cooling tailor made Customized OEM cooling units Product range www.efcooling.com S W I S S M A D E WK water-cooling equipment «There is no dispute nowadays regarding the importance of
More informationNOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS
- 1 - NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS S.J. Metcalf, Z. Tamainot-Telto (1) and R.E. Critoph School of Engineering, University of Warwick, Coventry CV4 7AL, UK Abstract: A new
More informationCOOLING SYSTEM. Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... DESCRIPTION...
COOLING SYSTEM DESCRIPTION... Page CO-2 TROUBLESHOOTING... CO-4 CHECK AND REPLACEMEANT OF ENGINE COOLANT... WATER PUMP... CO-5 CO-6 THERMOSTAT... CO-8 RADIATOR... CO-9 CO-2 COOLING SYSTEM - Description
More informationB.C.S. Shop Heaters 26, 30 & 36 (36 shown)
BIOMASS COMBUSTION SYSTEMS, INC. 67 MILLBROOK ST., SUITE 502 WORCESTER, MA 01606 508-798-5970 - FAX 508-798-5971 B.C.S. Shop Heaters 26, 30 & 36 (36 shown) INSTALLATION MANUAL HAND FIRED SYSTEMS 8-09 Biomass
More informationUSER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw
The TopStart is a compact electric coolant heater with circulating pump for marine engines, generating sets and all types of vehicles located inside or outside (protected place only). TABLE OF CONTENTS
More informationCentrifugal Separation. Working principles and benefits
Centrifugal Separation Working principles and benefits Centrifugal Separation the best approach to cleaning fluids On-site cleaning of industrial fluids oils, coolants and wash liquids is a must in most
More informationA formula for success
A formula for success Heat transfer solutions for process applications Excellence in the making When it comes to process industries, heat transfer isn t one-size-fits-all. You need a partner who knows
More informationAUTOMOTIVE THERMAL SYSTEMS CLIMATE SYSTEM COMPONENTS
AUTOMOTIVE THERMAL SYSTEMS CLIMATE SYSTEM COMPONENTS Every day while you drive... we enable your climate system to perform for you. More than 3,000 High- Climate System Components for Cars, Vans and Trucks
More informationPEINEMANN EQUIPMENT PRODUCT RANGE
EINEMANN QUIPMENT PRODUCT RANGE 2018 Single Lance Tube Cleaner (XLTC) Semi automatic cleaning system for improved operator safety. Excellent cleaning results due to consistent speed and 2 way cleaning.
More informationDemand new standards Semi-welded plate heat exchangers in high pressure applications
Demand new standards Semi-welded plate heat exchangers in high pressure applications Tommy Ångbäck Alfa Laval SCHAFFHAUSEN, 29 th of June 2018 Schaffhausen, 29 th of June 2018 Page 2 Higher pressures demand
More informationOWNER S. m a n u a l C P L S E R I E S
OWNER S m a n u a l C P L S E R I E S CONTENTS 1 2 Introduction 3 Wall Control Functions 7 Drain Valve & Bleed System 8 Maintenance 10 Troubleshooting INTRODUCTION 2 Congratulations on choosing a new cooler
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationAIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING
AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING CHEMICAL PLANTS CURING ROOMS DRYING KILNS FACTORIES GASIFICATION PLANTS GREENHOUSES PAPER MILLS
More informationTHERMAL SOLUTIONS FINNED TUBES AND HEAT EXCHANGERS FOR GREATER EFFICIENCY
THERMAL SOLUTIONS FINNED TUBES AND HEAT EXCHANGERS FOR GREATER EFFICIENCY FINNED TUBES AND HEAT EXCHANGERS FOR GREATER Whether for condensation or evaporation, clean or corrosive media, or the most stringent
More informationIJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):
IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online): 2349-6010 Githin V Sam Jethin Babu Jesvin Sam Jithin Victor Abstract Loop heat pipes
More informationSCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS
SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS API Schmidt-Bretten Leadership in plate heat exchangers since 1879. API Schmidt-Bretten traces its roots to 1879 in Germany when company founder Wilhelm
More informationINSTRUCTION MANUAL BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.
INSTRUCTION MANUAL MODEL NUMBER : WD31EC THERMOELECTRIC WATER DISPENSER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. Avanti has a policy of continuous improvement on
More informationLargo & Allegro. Air Compressors. Largo & Allegro 31-90
Largo & Allegro Air Compressors Largo & Allegro 31-90 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer compressed
More informationHeat Transfer Equipment
Heat Transfer Equipment THE BROADEST SELECTION AVAILABLE FOR GENERAL HEATING AND COOLING. PR ODUC Shell & Tube Heat Exchangers PRE-ENGINEERED FOR GENERAL APPLICATIONS SX2000 Pre-engineered fixed tubesheet
More informationHeating and Cooling Systems
Heating and Cooling Systems Figure 1. Typical Engine Cooling System Introduction Engines generate a great amount of heat. This heat is created when the fuel and air mixture is ignited and expands inside
More informationDry-Running Rotary Screw Compressors
Dry-Running Rotary Screw Compressors 2-Stage, Free air delivery up to 1 m 3 /min, Pressure,, and bar The new dimension in oil-free compression With logical component layout and exceptional attention to
More informationSondex - A World of Heat Exchangers For All Applications
Sondex - A World of Heat Exchangers For All Applications SONDEX HEAD OFFICE Sondex - A Leading Manufacturer of Plate Heat Exchangers Sondex A/S, a Danish company, was founded in 1984 by Mr. Aa. Søndergaard
More informationDriven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf
Driven by CLIMATISATION Excellence for professionals Bosch air conditioning service units for R-134a and R-1234yf A/C service from Bosch Air conditioning systems in vehicles require regular maintenance.
More informationAGRICULTURE AND FORESTRY CONSTRUCTION AND MINING AUTOMOTIVE, COMMERCIAL VEHICLES AND RAILWAYS INDUSTRIAL EQUIPMENT
RAAL is a manufacturer of complete cooling systems and heat exchangers, made of aluminium alloys and stainless steel, in brazed construction: radiators, oil coolers, air coolers, condensers and combined
More informationASPHALT PLANT. atlasindustries.in
ASPHALT PLANT Available as stationary and mobile. STATIONARY VARIANTS: DM 45 (40-60 tph), DM 50 (60-90 tph), DM 60 (90-120 tph) MOBILE VARIANTS: MDM 45 (40-60 tph), MDM 50 (60-90 tph), MDM 60 (90-120 tph)
More informationASPHALT PLANT. MOBILE VARIANTS: MDDM 45 (40-60 tph), MDDM 50 (60-90 tph), MDDM 60 ( tph) atlasindustries.in
ASPHALT PLANT Available as stationary and mobile. STATIONARY VARIANTS: DDM 45 (40-60 tph), DDM 50 (60-90 tph), DDM 60 (90-120 tph) MOBILE VARIANTS: MDDM 45 (40-60 tph), MDDM 50 (60-90 tph), MDDM 60 (90-120
More informationRollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V
Rollair Air Compressors Rollair 40 to 125 and Rollair 40 V to 125 V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial experience.
More informationREFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE
REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE The intelligent Refrigeration Compressed Why is Compressed Air processed? Compressed air is an essential form of driving and process energy in all fields
More informationRoof top SPACE RPC 450Z R407C M011
Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per
More informationSOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59
SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery
More informationAdvantages / Characteristics
Air to Air 50 W 30 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 70 W 36 W cooling capacity 163x104x144mm (LxBxH) 1,9 kg Air to Air 75 W 30 W cooling capacity 130x109x163mm (LxBxH) 1,5 kg
More informationDOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded
More informationCooler Manual XRC-3012-WA 3000 Watt water to air cooler
Industrial X-Ray Cooler Manual XRC-3012-WA 3000 Watt water to air cooler XRC-3012-WA, Doc.-No. 50005645 Page 1 of 13 Document history Version Date Author Amendment(s) Status 12/15/2008 St. Haferl released
More informationInstallation Instructions
Suzuki Samurai Coolant and Water Hose Kit (SKU# SER-CHK) Installation Instructions SER-HHCK SER-WPI SER-ROP CAUTION: Safety glasses should be worn at all times when working with vehicles and related tools
More information9. Cooling Water System
9.1 Water quality The fresh water in the cooling water system of the engine must fulfil the following requirements: ph... Hardness... Chlorides... Sulphates... min. 6.5...8.5 max. 10 dh max. 80 mg/l max.
More informationNessie High Pressure Water Mist Components for Fire Fighting
Nessie High Pressure Water Mist Components for Fire Fighting Generally Quick overview of the Nessie product portfolio used in Fire Fighting applications within Marine, Mobile and Spot systems typically
More informationReplacement Fractional Horsepower Motors
TOTALINE UNIVERSAL AFTERMARKET MOTORS Replacement Fractional Horsepower Motors for the HVAC/R Industry TRUST TOTALINE ON YOUR TRUCK DIRECT DRIVE BLOWER MOTORS Totaline Direct Drive Blower Motors are three
More informationVacuum Packages and Central Systems
Vacuum Packages and Central Systems What Defines Elmo Rietschle Custom Engineered Solutions Elmo Rietschle specializes in the engineering, design and fabrication of vacuum systems from simple to complex.
More informationCENTRIFUGAL AIR CONDENSERS
OPERATING INSTRUCTIONS INSTALLATION COMMISSIONING OPERATING MAINTENANCE (must be given to the end user in order to complete the operating manual during the equipment service life) CAC and SIROCCO CENTRIFUGAL
More informationHeader Tank Heat Exchangers
Header Tank Heat Exchangers Heat Transfer Technology from owman Heat Exchanger Technology by World Leader in Heat Exchanger Technology Staying cool under owman Header Tank Heat Exchangers For marine propulsion
More informationIndustrial Applications
Industrial Applications SENSING AND CONTROL Part Innovation. Part Engineering. Total Solutions. HW H29 Industrial Broch_MM.indd 1 1/3/08 9:27:17 AM Industrial Applications Only one company offers more
More informationACCU-THERM PLATE HEAT EXCHANGER
ACCU-THERM PLATE HEAT EXCHANGER HEAT TRANSFER PRODUCTS Accu-Therm Operation Accu-Therm Plate Heat Exchangers Accu-Therm plate heat exchangers are designed to provide you worry-free, highly efficient heat
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationSOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS
SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS SOLAR THERMAL SOLUTIONS The great advantage of having a Solar Water heater is ITS FREE! The benefits
More informationRSW D / RSWF D water-injected, with direct drive
Oil-free screw compressors RSW D / RSWF D water-injected, with direct drive Made in Germany Motor power: 18.5 to 10.0 kw Water-injected screw compressors RENNER oil-free, water-injected screw compressors
More informationWith the world-renowned SIGMA PROFILE
www.kaeser.com Rotary Screw Compressors BSD/CSD/CSDX T SFC Series With the world-renowned SIGMA PROFILE Free air delivery 0.87 to 16.10 m³/min, Pressures 5.5 to 15 11 What do you look for in a compressor
More informationInstallation Guide Soil, Asphalt & Concrete De-icing Heating Ribbons
Installation Guide Soil, Asphalt & Concrete De-icing Heating Ribbons Page 1 of 11 Important legal notice: Area laws differ concerning the handling and installation of heating cables, building materials,
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More informationAir conditioning and chillers. Customized heat transfer solutions
Air conditioning and chillers Customized heat transfer solutions Heat transfer solutions that will help you break barriers 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. Condenser single or double circuit Evaporator single
More informationChapter 39 Cooling System Fundamentals Test
TERRY FOX AUTOMOTIVE Chapter 39 Cooling System Fundamentals Test When you are done this test guess what you think you will receive for a mark below. If you are within 2 of your actual score you will receive
More informationConnection of auxiliary heater in coolant circuit of W12 engine
Coolant circuit Connection of auxiliary heater in coolant circuit of W12 engine If the auxiliary heater is started when the engine is switched off, the coolant shutoff valve closes. The recirculating pump
More informationCyclone KB4 Debris Blower MEGA Debris Blower Cyclone Squared Debris Blower Cyclone PTO Debris Blower Cyclone 8000 Debris Blower Kubota F-80 Series
Cyclone KB4 Debris Blower MEGA Debris Blower Cyclone Squared Debris Blower Cyclone PTO Debris Blower Cyclone 8000 Debris Blower Kubota F-80 Series Front Mount Debris Blower Grasshopper Front Mount Debris
More informationENGLISH USER S GUIDE ThermoCar from 0,5 to 2 kw
The is a universal tank-style electric coolant heater to preheat engines. It is meant for either stationary (generating sets) or mobile applications (all types of vehicles). The choice of high-quality
More informationPerformance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS
Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS 05/2017 2 Picture credits: Fotolia.com ( industrieblick, Kenishirotie, surawutob, gmstockstudio). Content ADSORPTION CHILLER AGGREGATES
More informationDK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS
DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS The DKheat exchanger: Certified for maximum 130 bar at maximum 150 C CO 2 refrigerant is the perfect partner for heat recovery due to the high
More informationPermutadores de calor
refrigerados a água - Hypercool Aftercoolers can be installed immediately downstream of compressors or blowers in order to remove over 80 % of the condensate. Their function is to protect the entire compessed
More informationFilabot EX6 Extruder. Operation Manual. CAUTION! Read Carefully. Filabot Vermont, USA, Earth
Filabot Vermont, USA, Earth 1-802-505-6772 CAUTION! Read Carefully HOT MATERIALS & SURFACES Use gloves and eye protection while operating the EX6 Extruder. The barrel and nozzle are HOT and melted plastic
More informationPerformance at heart. Alfa Laval T35/TS35 gasketed plate heat exchanger
Performance at heart Alfa Laval T35/TS35 gasketed plate heat exchanger The next generation heat exchanger Alfa Laval s all-new T35/TS35 gasketed plate heat exchanger offers many advantages: High uptime
More informationMain technical datas:
DCS - DCVS Dry Coolers Frigosystem, the patent holder for free cooling and dual free cooling in single frame, present the new generation line of DRY COOLERS, born to satisfy the request of cost saving.
More informationGüntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!
Güntner Info finoox technology fin and tube heat exchangers Tailor-made solutions! Heat exchangers Knowledge-based engineering Special Air Conditioning and Refrigeration applications and the cooling of
More information50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw
Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationDistributed By: M&M Control Service, Inc Building Technologies
Building Technologies Combustion Control Systems Count on Siemens. Siemens Building Technologies, the worldwide industry leader in combustion controls, delivers globally approved products specifically
More information6. Cooling System XCITING 400i. This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i.
6. Cooling System XCITING 400i Cooling System This chapter covers the location and servicing of the cooling system components for the KYMCO XCITING 400i. Coolant... 6-3~6-11 Radiator... 6-12~6-23 Thermostat...
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating
More informationIncreased Performance Higher System Efficiency Low Refrigerant Charge Compact Design
A Wholly Owned Subsidiary of EVAPCO ADVANCED MicroChannel T E C H N O L O G Y Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design MADE IN THE USA MicroChannel Heat Excha
More informationDRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL
ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com
More informationtailored solutions and engineering
UV SERIES ROTARY VANE VACUUM PUMPS Vacuum solutions for industrial applications Vacuum is the energy that Pneumofore delivers to its worldwide customers, ensuring efficiency, reliability and accuracy in
More informationWHHR Midi & Midi Lite
WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page