Fermentor, 15-L STANDARD OPERATING PROCEDURE

Size: px
Start display at page:

Download "Fermentor, 15-L STANDARD OPERATING PROCEDURE"

Transcription

1 STANDARD OPERATING PROCEDURE Fermentor, 15-L Model: NLF-22 Manufacturer: Bioengineering AG Location: Fermentation Facility, 1621 Food Sciences Building Publication Date: 01/22/2015 Iowa State University does not discriminate on the basis of race, color, age, ethnicity, religion, national origin, pregnancy, sexual orientation, gender identity, genetic information, sex, marital status, disability, or status as a U.S. veteran. Inquiries regarding non-discrimination policies may be directed to Office of Equal Opportunity, 3350 Beardshear Hall, 515 Morrill Road, Ames, Iowa 50011, Tel , eooffice@iastate.edu.

2 Description and Uses The Bioengineering NLF-22 Fermentor can be used for batch, fed-batch or continuous culture with automated control of ph, dissolved oxygen (DO), agitation, and temperature. It has a maximum volume of 15-L and a maximum operating temperature of 150 C. Power Specifications Motor: Bioengineering NLF-22 Voltage/Amperage: 220V/30A Speed/Frequency: Variable speed control@50-60 Hz. Maximum Operating Volume: 15-L Maximum Operating Temperature: 150 C For further information on power specifications, please see the Operating Manual located in the Fermentation Facility, 1621 Food Sciences Building. Potential Hazards and Safety Precautions High Voltage/Possible Electric Shock (220-V) Make sure that the wall outlet receptacle is properly wired and grounded, and matches the instrument s power cord and plug. Do not touch the power cord or plug if hands or feet are wet, or if standing on a wet/damp surface, as severe electrical shock or death may result. Excessive Weight/Possible Damage to Hands or Fingers when Moving or Repositioning Parts Certain parts of the fermentor, such as the upper lid, are very heavy. Use extreme caution when handling or moving these parts during fermentor assembly/disassembly. If available, wear shoes with steel caps when using the fermentor. Combustibility and Explosion/Possible Physical Damage or Injury Do not use the fermentor with materials capable of developing flammable or explosive vapors. Hot Surfaces/Possible Burns to Hands and/or Extremeties The fermentor is made of stainless steel and has a jacket that is filled with steam under pressure during the sterilization-in-place (SIP) process. As a result, the outer surfaces of the fermentor become HOT enough to cause serious skin burns if the fermentor is touched. Use extreme caution when working near the fermentor during sterilization. 2

3 Biohazard/Possible Infection from use of Pathogenic Microbes Normal operation involves the use of many types of microorganisms, all of which can be opportunistic pathogens. Occasional use may also involve working with genetically modified microbes. Use extreme caution and good sterile techniques when working with these organisms. After use, autoclave the fermentor to kill any remaining microbes. Required Personal Protective Equipment Lab Coat Hair Net Safety Glasses or Goggles No Open-toed or Open-heeled Shoes Insulated Rubber Gloves Steel-toed Shoes are recommended Required Training *Denotes courses offered online Machine & Site-Specific Training Fire Safety & Extinguisher Training* Laboratory Safety: Core Concepts* Laboratory Safety: Spill Procedures Bloodborne Pathogens and Sharps Safety* Operation Operation: Start-up 1. Be sure to complete all the required training listed above, including machine and site-specific training by the Fermentation Facility manager. 2. The Operating Manual provides a more complete description of the Bioengineering NLF-22 Fermentor. Be sure to read the manual before operating the fermentor to become familiar with its correct operation and individual component parts. 3. Be sure the drain port is closed. 4. Install the temperature probe (located on the side of the fermentor). 5. Install any other probes, if needed, such as the ph or O 2 probe. Note: If the ph probe is to be used, it must first be calibrated. Refer to Section VII: Calibration of the ph Probe in the Operating Manual. 3

4 6. Add media to the fermentor. 7. Install the top plate by performing the following steps: a. First, apply a small amount of silicone grease to the O-ring on the underside of the plate. b. If the fermentor is to be aerated, be sure that one of the openings in the top plate aligns correctly with the conical opening of the sparge tube in the fermentor. c. Insert the eight (8) screws in the plate. Tighten by hand, then with the T-shaped Allen wrench that is available. Tighten screws in a crosswise manner. Note: The top plate is heavy. Be sure to get a firm grip on the plate when attaching it to the fermentor. Be sure to wear close-toed shoes or (preferably) safety shoes with steel caps, if available. 8. Attach fittings to the top plate as follows: a. Light b. Pressure gauge c. Pressure relief valve d. Condenser with exhaust air filter (EAF). Note: Open the valve on the EAF 3-4 turns before starting the sterilization process. e. If the fermentor is to be sparged with air or oxygen, sterilize the air filter separately in advance using the autoclave. Also, there are several sizes of needles for introducing additives to the fermentor. Note: Be sure to use the large bore (~8mm) needle for sparging. The other needles have a narrower bore. If the wrong needle is used, there will be a gap between the needle and the sparge tube. This will result in most of the air not going into the fermentation broth, but lost into the headspace instead. f. Check to make sure all head-plate ports are either sealed with a blind plug or appropriate fitting. Make sure all lower ports are secured properly with blind plugs or securely fastened probes. Note: Failure to complete this step can result in serious physical injury! 9. Open the valve on the Sample/Drain-Port Steam Supply. This will send steam to the sample port to sterilize it. 10. Open the steam supply. This is valve with a green handle near the floor on the north wall of the Fermentation Facility (1621 Food Sciences Building), behind the 100-L fermentor. 11. Open the cold water supply. This is located near the floor on the north wall of the Fermentation Facility. Water is delivered to the fermentor via a ~¾" diameter green hose. 4

5 Operation: Sterilization 1. Turn on the temperature/ph control box (this is the grey box on the left in Figure 1). 2. Turn the Agitation Control knob fully counterclockwise. This is located on the agitation control box (the grey box on the right in Figure 1 above). Turn ON the power to the agitation control box by twisting the RED power knob to the right. Turn the Agitation Control knob clockwise to start the agitator. Note: During sterilization, the agitator should be set to and kept at ~300 rpm. The agitation ensures that the fermentor contents are heated uniformly. 3. Turn the circulation pump to ON by using the toggle switch on agitation control box. 4. Set the parameters for the sterilization at 121 C as follows: Figure 1 a. Two temperature set points must be entered. Press the arrow on the far left side of the temperature display. Then, press the arrow on the far right side of the display to select the desired set point. Use the UP and DOWN triangular arrows to enter the temperature. Save the setting by pressing the arrow on the far right side of the display. b. Repeat this process for the second set point. For sterilization, set both set points at 121 C. c. When both set points have been entered, press the arrow on the far left side of the display. d. Set the water and steam toggle switches to the Controller (DOWN) positions. 5. While the fermentor is heating up, the valve on the exhaust air filter (EAF) should be in the open position (~3-4 turns counter-clockwise). If the valve is closed, open it carefully. Note: Do not stand in front of the outlet, as condensate from the last run may be present in the EAF. If so, hot water and/ or steam may gush out of the EAF and cause burns! Stand off to the side while opening the valve. 6. As the fermentor and contents approach the sterilization temperature (121 C), steam will begin to exit the EAF. When this happens, wait seconds, then fully close the EAF valve. This seals the fermentor and allows the internal pressure to rise to 1 atmosphere (~1 bar) for sterilization to occur. 7. Below the temperature display are two toggle switches to control the flow of water and steam to the fermentor. The middle position is OFF. Flip both switches DOWN to the Controller position. This will send steam and cooling water to the fermentor. With the water and steam control toggle switches in the Controller position, the heating process is under automatic control by the control box. The steam and cooling water control valves perform a balancing act to keep the temperature at 121 C. The solenoid switches in these valves open and close as needed to send steam or cooling water to the fermentor to maintain the set-point temperature. 8. The fermentor should be held at 121 C and ~1 bar for 20 minutes to sterilize the contents. With steam flowing to the fermentor, the temperature eventually reaches 121 C. At this point, start timing the sterilization. Note: The temperature control is not perfect. As a result, temperature swings of C above and below the set point will occur. Lower temperature swings below 121 C occur more frequently. If this happens, flip the steam control switch up from Controller to Manual. 5

6 This will send more steam to the fermentor to raise the temperature, which may go as high as C. At this point, flip the steam control switch back to Controller. If the temperature again drops below 121 C, repeat this process as often as necessary over the 20-minute sterilization period. 9. Place the HOT sign on top of the fermentor to warn against touching the vessel. 10. During sterilization, steam will be sent to the sample port, and can be seen exiting the sampling tube. When this occurs, turn the knob on the sample port valve until it is open ~½ turn. This will allow steam to continue to flow to the sample port, but avoids the use of excess steam. The steam sterilizes the sample port to prevent contamination of the fermentor contents during sampling. Operation: Fermentation 1. After 20 min (or about 1 min before the end of the sterilization time), change the set-point temperature on the control box to the desired fermentation temperature. This will send cooling water to the fermentor to lower the temperature. Note: The steam and cold water should be left open during the fermentation to maintain the desired temperature in the vessel. Keeping the steam supply open also ensures that steam continually flows to the sampling port to prevent contamination during sampling. 2. When the fermentation temperature reaches ~105 C, open the valve on the EAF about 3-4 turns. This prevents a vacuum from forming in the vessel as the contents cool. Note: Do not stand in front of the outlet, as steam or hot water will be forcibly ejected when the valve is opened and may cause injury! 3. If the organism to be grown in the fermentor produces a surfactant (e.g., B. subtilis) that is to be collected and causes the media to foam, then close the EAF valve completely once the fermentation temperature has been reached. Note: If this is not done, the foam will exit the fermentor and be lost. 4. The cooling water will lower the temperature of the fermentor and its contents fairly quickly (~30 min). However, the temperature of the vessel above the level of the water jacket will remain hot for several hours. Note: Do not touch this part of the fermentor, especially the top plate, for at least 4 hours after the desired culture temperature has been reached. 5. When the fermentor has cooled, ancillary equipment may be attached to the fermentor as follows: a. Air inlet filter (if aeration or sparging is required, the filter should be sterilized separately in advance using the autoclave); b. Sterile tubing for adding sterile medium supplements and/or inocula to the fermentor; c. Cooling water lines to the condenser; d. Other equipment deemed necessary for the fermentation. NOTE: The attachment of tubing, etc. (a and b above) requires removal of one or more stainlesssteel (SS) plugs from the fermentor cover, then insertion of a sterile large-bore needle through the septa beneath the plugs. Prior to insertion of the needle(s), squirt several milliliters of 70% ethanol, methanol, or isopropyl alcohol on the septa to minimize possible contamination. 6

7 6. When the fermentor reaches the desired temperature, set the operating parameters as follows: a. Agitation (stirring): Turn ON the agitation control box. b. Turn the agitation control knob clockwise to the desired stirring speed; c. If required, open the air supply and, using the rotameter, d. set the air flow to the desired rate (l/min). e. If the culture is to be aerated, the air filter and connecting tubing must be separately sterilized in advance using the autoclave and then, once sterilized, attached to the fermentor. 7. Inoculate the fermentor as follows: a. A pre-culture of the organism of choice should be prepared in advance. To transfer this to the fermentor, prepare an appropriately sized glass or plastic bottle. This must have a screw cap with a siphon that reaches to the bottom of the bottle. b. If needed, also add a stir bar to keep the culture suspended. c. To the upper (outer) end of the siphon, attach a length of rubber tubing ~3 feet long. Attach an oversize-bore needle d. to the tubing. Cover the needle with a metal sleeve or aluminum foil, then sterilize the bottle, tubing and needle. e. Aseptically transfer a pre-determined volume of the pre-culture to the sterile bottle, along with any other fermentation additives, e.g., media supplements, etc. Place the bottle on a stir plate to mix the contents and keep the cells in suspension. f. Insert the needle through one of the septa on the fermentor s top plate. g. Attach the tubing to a peristaltic pump. Turn on the pump to deliver the inoculum, etc., into the fermentor. h. When this is done, remove the needle from the septum and cover the septum with a stainlesssteel plug. 8. Monitor the fermentation as follows: a. Samples can be periodically taken from the fermentor to measure growth, substrate utilization, product formation, etc. b. The sample/drain port at the bottom of the fermentor is constantly heated by steam, so it is HOT! Note: You must turn OFF the steam to the drain port ~10 minutes prior to sampling. If you must draw a sample before the 10-minute cooling period ends, always wear waterproof-insulated gloves before proceeding with the following steps. c. Open the valve by slowly lifting up valve lever. d. Allow ~25 ml of fermentor contents to drain into a waste container. This clears the dead volume from the drain tube. e. Collect the sample for monitoring. 9. Close the drain valve and re-open the steam supply to the sampling port. Then, autoclave the contents of the waste container. 7

8 Operation: Harvest and Shutdown 1. Shut off the main steam supply valve (green handle, along the north wall of the Fermentation Facility). 2. Shut off the main water supply valve (yellow handle, along the north wall of the Fermentation Facility). 3. Move the Steam and Water toggle switches to the OFF position. 4. Shut off main power switch to the temperature/ph control box. 5. Shut off the circulation pump. 6. Turn the Agitation Control knob fully counterclockwise to stop the agitator. 7. Shut off the main power to the agitation control box. 8. Reduce the airflow to 1-2 LPM. Note: The flow of air is necessary to help push the contents from the fermentor. 9. Open the exhaust valve if necessary. 10. Close the drain-port steam valve. 11. Remove the drain-port hose. Then, place a container under drain port and slowly open (press down) the drain-port valve to collect the fermentation broth. After collection is complete, close the drainport valve. 12. Completely shut off the airflow. 13. Remove the pressure gauge from the vessel head plate and place a funnel in the resulting hole. 14. Pour tap water into the funnel until the fermentor is about half full. 15. Remove the funnel and replace the pressure gauge. 16. Sterilize the fermentor and its contents (see Sterilization procedure listed earlier) to kill any organisms remaining in the fermentor. 17. When the sterilization is complete and the fermentor has cooled, drain and dispose of the fermentor contents. 18. Report any operational difficulties to the Fermentation Facility manager and initiate clean-up procedures. Clean-up Procedures 1. After the fermentor has been harvested, remove all apparati (air filter, light, pressure gauge, etc.) from the top of the fermentor. 2. With the available T-shaped, 6-mm hexagonal Allen wrench, remove the top plate. 3. Fill the fermentor about halfway with warm tap water. 4. Add a non-abrasive detergent (such as Joy or Ivory Liquid) and turn on the agitator (~300 rpm) for a few minutes. 8

9 5. After the allotted time, turn OFF the agitator. Then, scrub the inside of the fermentor with a brush or sponge. 6. Turn ON the agitator again and drain the fermentor. When drained, turn OFF the agitator. 7. Rinse the inside of the fermentor with distilled water. Then, drain again. 8. Clean the head plate, light, probes, etc. in the sink with non-abrasive detergents. Then, rinse with distilled water. 9. Fill the fermentor with tap water. 10. Replace the cover plate and any plugs, pressure gauge, etc. so the fermentor is sealed. 11. Clean up the surrounding work area. 12. Initiate check-out procedures by having the fermentor and surrounding work area inspected by the Fermentation Facility manager. Machine Care and Maintenance The fermentor must be properly cleaned and inspected after each use. All final inspections are performed by the Fermentation Facility manager. All maintenance should be performed by the Fermentation Facility manager or a trained service technician. Accessories T-shaped, 6-mm hexagonal Allen wrench 9

Mixing Tank, 500 Gallon with Agitator

Mixing Tank, 500 Gallon with Agitator STANDARD OPERATING PROCEDURE Mixing Tank, 500 Gallon with Agitator Model: PCP Manufacturer: Paul Mueller Company Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 04/29/2015

More information

Mixer with Lifting Cart STANDARD OPERATING PROCEDURE

Mixer with Lifting Cart STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Mixer with Lifting Cart Model: XD-30VM Manufacturer: SPX Corporation, Lightnin Mixers Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 03/04/2014

More information

Mill, Microcut Grinder STANDARD OPERATING PROCEDURE

Mill, Microcut Grinder STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Mill, Microcut Grinder Model: MC-15 Manufacturer: Stephan Machinery, Inc. Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 07/23/2014 Iowa

More information

Centrifuge STANDARD OPERATING PROCEDURE

Centrifuge STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Centrifuge Model: Sorvall, RC-3B Plus Manufacturer: Kendro Laboratory Products Location: Fermentation Support, 1620 Food Sciences Building Publication Date: 01/23/2015 Iowa

More information

Extruder, Twin-screw, Large STANDARD OPERATING PROCEDURE

Extruder, Twin-screw, Large STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Extruder, Twin-screw, Large Model: Mic 27/GI-40D Manufacturer: Leistritz Extrusions Technik GmbH Location: Dry Processing Pilot Plant, 1851 Food Sciences Building Publication

More information

Centrifuge STANDARD OPERATING PROCEDURE

Centrifuge STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Centrifuge Model: Sorvall, RC-5B Plus Manufacturer: Kendro Laboratory Products Location: Technology Transfer Lab, 1568 Food Sciences Building Publication Date: 09/26/2014 Iowa

More information

Mixer, Planetary Food STANDARD OPERATING PROCEDURE

Mixer, Planetary Food STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Mixer, Planetary Food Model: SM-402-NA Manufacturer: Doyon Incorporated Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 03/26/2014 Iowa

More information

Jet Cooker with Pump and Hydro-heater

Jet Cooker with Pump and Hydro-heater STANDARD OPERATING PROCEDURE Jet Cooker with Pump and Hydro-heater Manufacturer: Hydro-Thermal Corporation Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 07/23/2014

More information

Bread Slicer, Countertop STANDARD OPERATING PROCEDURE

Bread Slicer, Countertop STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Bread Slicer, Countertop Model: 711 Manufacturer: Oliver Products Company Location: Processing Lab, 1384 Food Sciences Building Publication Date: 03/26/2014 Iowa State University

More information

Feeder, Screw STANDARD OPERATING PROCEDURE

Feeder, Screw STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Feeder, Screw Manufacturer: AccuRate, Inc. Location: Technology Transfer Pilot Plant, 1598 Food Sciences Building Publication Date: 02/04/2014 Iowa State University does not

More information

Jet Cooker STANDARD OPERATING PROCEDURE

Jet Cooker STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Jet Cooker Model: SC2-3 Manufacturer: Pick Heaters, Inc. Location: Wet Processing Pilot Plant, 1091 Food Sciences Building Publication Date: 07/23/2014 Iowa State University

More information

Mill, Ultra-Centrifugal STANDARD OPERATING PROCEDURE

Mill, Ultra-Centrifugal STANDARD OPERATING PROCEDURE STANDARD OPERATING PROCEDURE Mill, Ultra-Centrifugal Model: ZM-1 Manufacturer: Retsch GmbH & Co. KG Location: Dry Processing Pilot Plant, 1851 Food Sciences Building Publication Date: 08/29/2014 Iowa State

More information

BENCHTOP FERMENTOR & BIOREACTOR SYSTEMS

BENCHTOP FERMENTOR & BIOREACTOR SYSTEMS BENCHTOP FERMENTOR & BIOREACTOR SYSTEMS A SELECT NEW RANGE OF VERSATILE, HIGH PERFORMANCE 3-20L AUTOCLAVABLE SYSTEMS WITH EASY-TO-USE TOUCHSCREEN CONTROLS www.cleaverscientifi c.com ...Introducing a new

More information

CONSTANT SUCTION UNIT

CONSTANT SUCTION UNIT CONSTANT SUCTION UNIT OPERATOR/MAINTENANCE M A N U A L Squire-Cogswell/Aeros Instruments Inc 1111 Lakeside Drive Gurnee, IL 60031-4099 1-800-662-5822/847-855-0800 Fax: 847-855-6218 www.aerosinstruments.com

More information

TECHNOSKLO Ltd. Držkov

TECHNOSKLO Ltd. Držkov TECHNOSKLO Ltd. Držkov Distillation apparatus for producing of distilled water TYPE DP 4000 Operating manual TECHNOSKLO Ltd. 468 24 Držkov 135 Czech Republic tel.: 00420 483 346 403 fax: 00420 483 385

More information

VAC-THEN-STEAM MV2010UKL OWNER S GUIDE

VAC-THEN-STEAM MV2010UKL OWNER S GUIDE VAC-THEN-STEAM MV00UKL OWNER S GUIDE MV00UKL_IB_ENG_00.indd IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS For Household Use Only WHEN USING YOUR SHARK VAC- THEN-STEAM, BASIC SAFETY PRECAUTIONS

More information

Desoldering Tool. Instruction Manual

Desoldering Tool. Instruction Manual Desoldering Tool Instruction Manual Thank you for purchasing the Hakko 472D desoldering tool with digital temperature display. Please read this manual before operating the Hakko 472D. Keep this manual

More information

Model CWA200 Owner s Manual

Model CWA200 Owner s Manual Model CWA200 Owner s Manual ClearWaveAir Purifier Owner s Manual Model CWA200 Thank you for purchasing the ClearWaveAir air purifier. The ClearWaveAir system will greatly improve the air quality in your

More information

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Owner s Manual Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit Model AC375C Recover, Recycle, and Recharge Unit for R-12 or R-134a Refrigerant Voltage: 220 230; 50 60 Hz SAFETY DEFINITIONS:

More information

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

AGITATOR V DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY AGITATOR 20 120V INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE THE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use

More information

Conical Fermenter. Instructions

Conical Fermenter. Instructions Conical Fermenter Instructions What s in the Box?: 01. AIRLOCK Rubber Bung Fermenter lid Fermenter Body CONTENTS WHAT S IN THE BOX...P1 ANATOMY/SCHEMATICS...P2 FERMENTING WITH THE STANDARD FERMENTER...P.5

More information

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference. OWNER S MANUAL DEHUMIDIFIER ESPAÑOL FRANÇAIS Read this manual carefully before operating the appliance and retain it for future reference. Model : UD701KOG1 P/NO : MFL68026017 www.lg.com TABLE OF CONTENTS

More information

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS. TABLE OF CONTENTS 1 Table of Contents www.windsterhood.com Safety Information... 2 3 WALL MOUNT SERIES User s Manual RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS NOTE: PLEASE

More information

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers

Operating Manual Mark II Solid-State Digital Automatic Controlled Sterilizers Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers Rev. 070129 PLEASE READ CAREFULLY BEFORE ATTEMPTING TO OPERATE YOUR STERILIZER. Copyright: Consolidated Stills and Sterilizers

More information

ASPIRE Laboratory Aspirator

ASPIRE Laboratory Aspirator ASPIRE Laboratory Aspirator USER MANUAL Rev 2/14/18 Accuris Instruments / Benchmark Scientific Ph: (908) 769-5555 E-mail: info@accuris-usa.com (C) Benchmark Scientific, 2018 THE ACCURIS ASPIRE LABORATORY

More information

In order to be useful, many substances must be available in pure form.

In order to be useful, many substances must be available in pure form. DISTILLATION COLUMN INTRODUCTION In order to be useful, many substances must be available in pure form. In the real world substances are seldom found or produced pure, they are frequently found mixed together

More information

Antibiotic production by fermentation

Antibiotic production by fermentation Antibiotic production by fermentation Commodity: Antibiotic fermentation model SDL-1/3/5/7/10L Lab Scale Fermentor Aniaml Cell Vessel Fermentation of antibiotics details: 1. With compatible Price about

More information

ASSEMBLY & OPERATING INSTRUCTIONS

ASSEMBLY & OPERATING INSTRUCTIONS SD-BASIC SPRAY DRYER ASSEMBLY & OPERATING INSTRUCTIONS 1) Introduction 2) Safety / COSHH 3) General Safety Rules 4) Components Included 5) Packing List 6) Connection to Electrical Supply 7) Assembly and

More information

METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE

METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE 06.-March/0 SUMMARY. Introduction. Main Precautions. Main Components. Technical Characteristics. Installation and Pre-Operation.

More information

Standard Operating Procedures

Standard Operating Procedures CENTER FOR NANOSCALE SCIENCE AND ENGINEERING Standard Operating Procedures MMR Low Temperature Micro Probe Matt Deye and Brian Wajdyk Page 1 of 8 Important Gloves should be worn when handling stage, refrigerators,

More information

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3 User s Manual Index Topic Important safeguards 03 Safety features 05 Parts and accessories 05 Before first use 06 Operating instructions 06 Programme settings 08 Care and cleaning 09 Pressure canning guide

More information

Operator s Manual. Frozen Beverage Granita Machines

Operator s Manual. Frozen Beverage Granita Machines Thank you for purchasing this Vollrath equipment. Before operating the equipment, read and familiarize yourself with the following operating and safety instructions. SAVE THESE INSTRUCTIONS FOR FUTURE

More information

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information... - TABLE OF CONTENTS Table of Contents 1 www.windsterhood.com Safety Information... 2 3 ISLAND SERIES User s Manual RA-7630SS RA-7636SS RA-7642SS RA-7648SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING.

More information

Tornado Operations & Maintenance Manual

Tornado Operations & Maintenance Manual TORNADO INDUSTRIES 7401 W. LAWRENCE AVENUE CHICAGO, IL 60706 (708) 867-5100 FAX (708) 867-6968 www.tornadovac.com Tornado Operations & Maintenance Manual MODEL NO. 99690 BD 22/14, 99720 BD 26/14 L9722

More information

BIOSTAT D-DCU. Your Fast Lane to Production

BIOSTAT D-DCU. Your Fast Lane to Production Your Fast Lane to Production Agenda Introduction System Overview Hybrid Solution Drivers of Standardization for Stainless Steel Fermentation Systems Key Drivers for Standardization Optimized and proven

More information

AUC Cell Washer. User Manual

AUC Cell Washer. User Manual AUC Cell Washer User Manual WARRANTY Spin Analytical Inc., warrants this product to be defect free in both material and workmanship for 90 days from the date of shipment. Labor services are guaranteed

More information

Operating / User Manual

Operating / User Manual UniARM Surgical Support System Operating / User Manual Version 1.1 MITAKA KOHKI Co., Ltd. 1. Introduction Introduction Thank you for purchasing the UniARM for use in surgical procedures. To use the device

More information

EPISD RISK MANAGEMENT. Custodial Safety

EPISD RISK MANAGEMENT. Custodial Safety Custodial Safety Custodial Safety The on-going maintenance of school and support facilities require custodians to perform a variety of tasks. These tasks must be performed in a neat, orderly, efficient,

More information

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up Owner s Guide J8810 / SM-610 Herbal Steamer Package Contents: 1 Steamer Unit 1 Herbal Basket 1 Glass Container 1 Stand with rollers (Unassembled) 1 Silicone Rubber O-ring Assembly Instructions: Separate

More information

Operating Instructions

Operating Instructions Operating Instructions BA-003 Read and understand this manual before use. Keep this manual for future reference. CONFORMS TO UL STD.No.1017 Certified to CSA STD C22.2 No.243-10 For questions or concerns

More information

BIOFLO /CELLIGEN 115 BENCHTOP FERMENTOR & BIOREACTOR VERSATILE L AUTOCLAVABLE SYSTEMS WITH EASY-TO-USE TOUCHSCREEN CONTROLS

BIOFLO /CELLIGEN 115 BENCHTOP FERMENTOR & BIOREACTOR VERSATILE L AUTOCLAVABLE SYSTEMS WITH EASY-TO-USE TOUCHSCREEN CONTROLS BIOFLO /CELLIGEN 115 BENCHTOP FERMENTOR & BIOREACTOR VERSATILE 1.3 14.0L AUTOCLAVABLE SYSTEMS WITH EASY-TO-USE TOUCHSCREEN CONTROLS Versatile BioFlo /CelliGen 115 Fermentors and Easy-to-use, exceptionally

More information

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling

More information

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International Indoor/Outdoor Electric Patio Heater Model No: HP1-15-50 Operating Instructions 3098007 HP1-15-50 2009 Soleus Air International Thank you for choosing a Soleus Air Indoor/Outdoor Patio Heater. This owner

More information

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer User Manual MS-H-Pro T Magnetic Hotplate-Stirrer with Timer Please read the User Manual carefully before use, and follow all operating and safety instructions!

More information

MODEL 7000 SUCTION UNIT

MODEL 7000 SUCTION UNIT MODEL 7000 SUCTION UNIT OPERATOR S MANUAL Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices

More information

Robobrew 35L All In One Brewery with Pump Model: 8695

Robobrew 35L All In One Brewery with Pump Model: 8695 Instruction Sheet Robobrew 35L All In One Brewery with Pump Model: 8695 WARNING IMPORTANT INFORMATION! 1. Please read this ENTIRE instruction sheet before using the Robobrew unit. If you are unsure about

More information

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV

OPERATOR S MANUAL FOR YOUR SAFETY. 4 Gallon / Liter Part No. PB408SV 120 VOLT WET / DRY VAC 4 Gallon / 15.14 Liter Part No. PB408SV FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. OPERATOR S MANUAL TABLE OF CONTENTS SECTION

More information

Model # VWK-2 INSTRUCTION MANUAL

Model # VWK-2 INSTRUCTION MANUAL Model # VWK-2 INSTRUCTION MANUAL Ver. March 2015 ALA Scientific Instruments Inc. 60 Marine Street Farmingdale, NY 11735 Tel. # 631.393.6401 Fax: # 631.393.6407 E-mail: support@alascience.com www.alascience.com

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS NOTE - Check with your local water authority for regulations regarding discharge of treated condensate

More information

WALLPAPER STEAMER. Model ASSEMBLY AND OPERATING INSTRUCTIONS

WALLPAPER STEAMER. Model ASSEMBLY AND OPERATING INSTRUCTIONS WALLPAPER STEAMER Model 91098 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright 2004 by Harbor Freight Tools.

More information

PERFORM Operating Document

PERFORM Operating Document PERFORM Operating Document Use and Maintenance of Tuttnauer Table-Top Autoclave PC-POD-CA-006-v03 Revision History Version Reason for Revision Date 01 New POD 13-Aug-13 02 POD Section 3.1.3 and 3.2 revised

More information

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V

* * English. Operator Manual. Carpet Cleaner Rev. 01 ( ) Model V R3 Carpet Cleaner English Operator Manual Model 9004199-230V R For the latest Parts manuals and other language Operator manuals, visit: www.tennantco.com/manuals 9003707 Rev. 01 (07-2016) *9003707* OPERATION

More information

User s Information Manual

User s Information Manual Gas-fired Water boiler Series 2 NOTICE: Series 1/Series 2 identification Read the boiler rating plate to determine the series number. The rating plate is located on the right side of the boiler. User s

More information

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. WALL MOUNT SERIES www.windsterhood.com User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

T1 SCRUBBER DRYER OPERATOR MANUAL

T1 SCRUBBER DRYER OPERATOR MANUAL T1 SCRUBBER DRYER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk Web:

More information

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY Wet/Dry Vacuums Operator s Manual Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www.vacmaster.com

More information

QuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc. REV C

QuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc.   REV C CENTI QuickStart Guide Automated Support Removal System PostProcess Technologies, Inc. www.postprocess.com REV C Copyright Copyright 2018 by PostProcess Technologies Inc. POSTPROCESS. All rights reserved.

More information

Refrigerant Recovery Machine. Model No Operating Manual

Refrigerant Recovery Machine. Model No Operating Manual Refrigerant Recovery Machine Model No. 25700 Operating Manual Safety Precautions WARNING : TO PREVENT PERSONAL INJURY AND / OR EQUIPMENT DAMAGE, CAUTION - Risk of injury. This equipment should only be

More information

PRE-INSTALLATION PROCEDURE

PRE-INSTALLATION PROCEDURE PRE-INSTALLATION PROCEDURE Required with each BLUPURA Water Treatment System. 1 each External Filter 1 each Chiller 1 each CO 2 Regulator 1 each External Filter 1 each Water Pressure Regulator 1 each 4

More information

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven 9990033 1 TABLE OF CONTENTS SECTION 1.0 SECTION 2.0 SECTION 3.0 SECTION 4.0 SECTION 5.0 SECTION 6.0 PRECAUTIONS SAFETY CONNECTION KIT

More information

CHLORIDE GASES CHLORIDES

CHLORIDE GASES CHLORIDES Note: Always have this machine s model and serial number (printed on the first page of this document) ready when calling Consolidated for service or parts. WARNING If this sterilizer s chamber is constructed

More information

ELECTRIC DRILL INSTRUCTIONS. Item #21285

ELECTRIC DRILL INSTRUCTIONS. Item #21285 ELECTRIC DRILL INSTRUCTIONS Item #21285 The EASTWOOD ELECTRIC DRILL is great for use on virtually all metals including steel, aluminum, brass and more. The powerful 6.3 Amp motor and 1/2 capacity chuck

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you

More information

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution S168-544-OO1E REV.A Schuco byallied MEDICAL ASPIRATOR MnrInI -33OA USER'S MANUAL A Caution Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by

More information

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly

Gen II Entree Bath. Maintenance Manual. All Models. Important Safety Instructions Read & Follow All Instructions Thoroughly Gen II Entree Bath All Models Maintenance Manual Important Safety Instructions Read & Follow All Instructions Thoroughly Note: The serial tag is at the first page of this manual package. The Standards

More information

BEFORE OPERATING THE MACHINE: WARNING

BEFORE OPERATING THE MACHINE: WARNING BEFORE OPERATING THE MACHINE: Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this

More information

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference. Before using your washing machine, please read this manual carefully and keep it for future reference. Washing Machine OWNER S MANUAL TRWTL-70 Read This Manual Inside you will find many helpful hints on

More information

Meat Slicer Instructions. Models: CFM-10 CFM 12

Meat Slicer Instructions. Models: CFM-10 CFM 12 Meat Slicer Instructions Models: CFM-10 CFM 12 Notice The power source must comply with the electric requirements on the label or it may cause fire or machine issues if improperly used. The machine must

More information

FLOW METER KIT #

FLOW METER KIT # FLOW METER KIT #80495684 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding

More information

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual UNDER CABINET SERIES WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

Operation Manual RANGE HOOD

Operation Manual RANGE HOOD Operation Manual RANGE HOOD MODEL: BUF-03A TABLE OF CONTENTS Safety Instructions... 2 Name of Parts... 4 How to Use... 5 Operating the Range Hood... 5 Care and Maintenance... 6 Disassembling... 7 Cleaning...

More information

OWNER S MANUAL VERSION 4.4 SERIAL # X-1 SINGLE LAYER PRESS. With EG-260 Variable Speed Grinder

OWNER S MANUAL VERSION 4.4 SERIAL # X-1 SINGLE LAYER PRESS. With EG-260 Variable Speed Grinder OWNER S MANUAL VERSION 4.4 CONFORMS TO UL STD 763, NSF/ANSI STD 8 CERTIFIED TO CSA STD C22.2 #195 CONFORMS TO CE, IEC TESTED X-1 SINGLE LAYER PRESS With EG-260 Variable Speed Grinder SERIAL # 2 20 INTRODUCTION

More information

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference Wet/Dry Vacuums Operator s Manual 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www.vacmaster.com Cleva North America 44 Parkway

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Manual Page 1 of 8. Manual. Laboratory autoclave

Manual Page 1 of 8. Manual. Laboratory autoclave Manual 17.11.2014 Page 1 of 8 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization 1. WARNINGS AND PRECAUTIONS 1.1. Caution should be exercised when handling instruments with sharp points, or cutting/drilling

More information

BMW E36 Thermostat Removal And Coolant Flush

BMW E36 Thermostat Removal And Coolant Flush BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could

More information

Multi-Mode Electrode pro

Multi-Mode Electrode pro Multi-Mode Electrode pro Manual 8.110.8018EN / 2015-06-30 Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Multi-Mode Electrode pro 6.1246.120

More information

HHP-300 EXTRACTOR 120V

HHP-300 EXTRACTOR 120V CARPET HHP-300 EXTRACTOR 120V 1 2 CORD 1 3 VAC PUMP UPHOLSTERY MODE INFORMATION & OPERATING INSTRUCTIONS DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTIONS IMPROPER USE OF THE

More information

Climate Control System

Climate Control System Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental

More information

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL KING COBRA 310 120V INFORMATION & OPERATING INSTRUCTIONS U. S. PRODUCTS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 56041963 IMPROPER USE OF THE MACHINE

More information

NOTE: THIS APPLIANCE MUST BE INSTALLED SOLELY AND EXCLUSIVELY BY A QUALIFIED TECHNICIAN.

NOTE: THIS APPLIANCE MUST BE INSTALLED SOLELY AND EXCLUSIVELY BY A QUALIFIED TECHNICIAN. Table of Contents 1. IMPORTANT SAFETY INSTRUCTIONS... 4 2. DESCRIPTION OF CONTROLS... 6 3. USING THE COOKTOP... 7 3.1 Ignition with safety device... 7 3.2 Practical advices to use the burners... 8 3.3

More information

CK247 JDW STEAM MOP Instruction Manual

CK247 JDW STEAM MOP Instruction Manual CK247 JDW STEAM MOP Instruction Manual Page 1 of 10 Plug Wiring (UK) This appliance is fitted with a BS1363 13 amp plug. If you have to replace the fuse, only those that are BSI approved to BS1362 and

More information

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. www.windsterhood.com User s Manual WS-63TB36SS WS-63TB42SS ISLAND SERIES NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED. This unit is designed

More information

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days Taylor PH61 Cleaning every 14 days Drain the Syrup Lines Remove each syrup feed tube from syrup bottle and let excess syrup drain from the feed tube back into the syrup bottle. When flow of syrup from

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

Model K 3000 G Part No

Model K 3000 G Part No K3000G Manual 11/30/01 4:56 PM Page 1 Model K 3000 G Part No. 1.133-110.0 High Pressure Washer Operator Manual Overview..................................1 Precautions...............................1-2

More information

Operation Manual Digital Heating Hotplate HP-1D

Operation Manual Digital Heating Hotplate HP-1D Operation Manual Digital Heating Hotplate HP-1D Before you operate the hot plate with external temperature probe, make sure that the external probe will be constantly soaked in your sample and not in the

More information

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS: 79202-00 79202-05 79202-30 79202-35 Approval Agency s Model 79202-00 & 79202-05 Model 79202-30 & 79202-35 Not recommended for pumping acid,

More information

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave Manual 20.2.2015 v1 Page 1 of 19 Manual Laboratory autoclave Autoclave using steam for the treatment of material and laboratory processes e.g. sterilization, as an aid in research and development CertoClav

More information

MARUTI ENGINEERING WORKS

MARUTI ENGINEERING WORKS 1 1. Introduction of company Maruti engineering works is started before 15 years old manufacturing unit. we have machine shop for machining work and fabrication work.we are making various types of fermenter.

More information

IMPORTANT SAFEGUARDS WARNING

IMPORTANT SAFEGUARDS WARNING IMPORTANT SAFEGUARDS When using an electric appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM CLEANER WARNING To reduce the

More information

LP GAS PIZZA OVEN USER MANUAL

LP GAS PIZZA OVEN USER MANUAL LP GAS PIZZA OVEN USER MANUAL To reduce the risk of fire, burn hazard or other injury, read the USER MANUAL carefully and completely before using this appliance FOR OUTDOOR USE ONLY Before Cleaning, make

More information

1998 Expedition/Navigator Workshop Manual

1998 Expedition/Navigator Workshop Manual Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:

More information

Model K 4400 G Part No High Pressure Washer

Model K 4400 G Part No High Pressure Washer Model K 4400 G Part No. 1.133-208.0 High Pressure Washer Table of Contents Overview..................................1 Precautions...............................1-2 Assembly Instructions.........................3

More information

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE: 1-866-902-9690 8:00 am to 5:00 pm, C.S.T., Monday - Friday www.forcetoolsusa.com TABLE OF CONTENTS

More information

HW-17 Record Cleaning Machine Setup and Instruction Manual

HW-17 Record Cleaning Machine Setup and Instruction Manual HW-17 Record Cleaning Machine Setup and Instruction Manual VPI Industries, Inc., 77 Cliffwood Ave. #3B, Cliffwood, NJ 07721 Phone: 732-583-6895, Email: Sales@vpiindustries.com http://www.vpiindustries.com

More information

Ultrasonic Cool Mist Humidifier

Ultrasonic Cool Mist Humidifier Model No.: LV450CH Ultrasonic Cool Mist Humidifier Questions or or Concerns? Please contact us Monday Mon-Fri 9:00AM-5:00PM - Friday am - PST 5:00 pm PST at support@levoit.com (888) 726-8520 email or at

More information

INSTRUCTIONS MANUAL PLANETARY MIXER. Model BPS-05

INSTRUCTIONS MANUAL PLANETARY MIXER. Model BPS-05 36214.0 - Março/2009 INSTRUCTIONS MANUAL PLANETARY MIXER Model BPS-05 SUMMARY 1. Introduction 01 1.1 Safety 01 1.2 Main Components 1.3 Technical Characteristics 01 02 2. Installation and Pre operation

More information