reliable innovative energetic dedicated trustworthy dynamic

Size: px
Start display at page:

Download "reliable innovative energetic dedicated trustworthy dynamic"

Transcription

1 reliable innovative energetic dedicated trustworthy dynamic At SANYO we are dedicated to creating synergy between people, the environment and technology. Our philosophy is to be a very dedicated partner. We will always try to support your ambition with the world's most innovative developments. From performance and reliability, to ergonomics and usability: our products are designed with you in mind. You and SANYO a perfect match. SANYO E&E Europe BV Medical Division Biomedical Business Unit SANYO Electric Co.,Ltd., Biomedical Division, Gunma is certified for; Quality management system: ISO9001/ Medical devices quality management system: ISO13485 Environmental management system: ISO SANYO E&E Europe BV Publication Number: 21645

2 ambitious Biomedical Equipment catalogue innovative reliable dedicated Your SANYO conservation incubation sterilisation

3 Message from the General Manager of Biomedical Division The moment I became responsible for the Biomedical Division I realized this division had a great reputation worldwide. Big market share has been built in Japan, Europe, The America s and Asia. The group has No 1 market share in ultra low temperature freezers. How to improve this? With my experience from the Medicom division, a highly recognized division in Japan with key products in medicine description and intelligent software systems I realized improvement can be made in the Biomedical division as well in this respect. Takaichi Kato If you combine Intelligence and the Think GAIA concept, our factory must come with intelligent green products. This was the start of my Intelligence and Ecology concept. With our intelligence, creating intelligent products because we want to be an environmental conscious division. Saving energy by creating more intelligent products. And as an outcome of the concept producing unique products the medical and laboratory field is waiting for. In a short time I was able to arrange extra experienced engineering capacity. The division moved to a new premises where all this experience, creativity and product control is combined. It lead to two revolutionary products, which will be introduced outside of Japan in the 1st half of 09 and many more to follow. We keep learning from our customers to produce intelligent world class products with the highest quality and in respect to the environment we all live in. I am looking forward to continue our worldwide customer relationship. Life itself is our key customer. creative Takaichi Kato General Manager Biomedical Division Commercial Solutions Company SANYO Electric Co., Ltd. intelligent

4 Your SANYO reliable dynamic At SANYO we are dedicated to creating synergy between people, the environment and technology. Our philosophy is to be a very dedicated partner. We will always try to support your ambition with the world's most innovative developments. From performance and reliability, to ergonomics and usability: our products are designed with you in mind. You and SANYO a perfect match.

5 Contents SANYO SANYO Medical 4 SANYO Service 6 SANYO Synergy in Europe 8 SANYO Brand Vision 10 Sterilisation Incubation Conservation -150ºC/-152ºC Freezers MDF-1156 / MDF-1156ATN 14 MDF-C2156VAN 18-86ºC Freezers MDF-U33V / MDF-U53V / MDF-U73V 21 MDF-C8V1 26 MDF-U3386S / MDF-U5386S / MDF-U7386S 28 MDF-U4186S 32 MDF-794 / MDF-594 / MDF-393 / MDF ºC/-40 C Freezers MDF-U MDF-136 / MDF-236 / MDF-436 / MDF-U537 / MDF-U537D / MDF-U333 / MDF-U Inventory rack system SANYO Inventory racks 45 Refrigerator with Freezer MPR-414F / MPR-214F 48 Refrigerators MPR-1410 / MPR-1410R / MPR-721 / MPR-721R 52 SANYO Bio Secure Biometric security 57 Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R 58 MPR-161D / MPR-311D 62 Bloodbank Refrigerators MBR-304GR / MBR-704GR / MBR-1404GR / MBR-107D / MBR-506D 66 Laboratory Refrigerators SRR-23GD / SRR-49GD / SRR-72GD / SRR-23FD / SRR-49FD 72 Isothermal Freezers CBS Isothermal -190 C Dry Storage Freezers 76 Liquid Nitrogen Storage CBS Cryosystems 78 CO 2 Incubators MCO-80IC Large scale incubator 83 MCO-AIC 86 MCO-18AIC / MCO-18AICUV 90 MCO-5AC 92 Airjacket CO 2 Incubators MCO-15AC 95 Waterjacket CO 2 Incubator MCO Multi-gas Incubators MCO-18M 100 MCO 5M 102 Multi-Cell Imaging Incubator InCu-VIEW Live 104 Plant Growth/ Environmental Test Chamber MLR-351 / MLR-351H 106 Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-553 / MIR-162 / MIR Orbital Shaker MIR-S Autoclaves MLS-3751L / MLS-3781L 1 MLS-24U / MLS-30U 124 Tabletop Autoclave SA-230FA / SA-230MA / SA-260FA / SA-260MA 128 Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S 130 Air Purifying System VIRUS WASHER 134 2

6 vision determination commitment Your SANYO HCFC/CFC-Free SANYO has developed refrigerants, which are not destructive to the ozone layer. SANYO is committed to HCFC/CFC-free refrigerants. CPU and Touch Pad The computer control system designed for low temperature application ensures accurate setting with touch-pad controls. LED Digital Display The strategically located LED digital display is very easy to read. Specially linked to the CPU computer control for instant reaction. Cascade Cooling System SANYO developed compressors feature time-tested refrigerants and lubricating oils. Air Filter The air filter used is specially located to give easy access for removal. The filter has the extra bonus of being washable for economy and easy maintenance. There is even a filter indicator to tell you it is time. Casters All models are mounted on wheeled casters to make any moving required easy. Remote Alarm An alarm is sounded at a remote location if ever a breakdown occurs. A peace of mind feature for off-hour times in particular. Automatic Alarm System Provides both an audible and visual temperature alarm when the temperature goes up more than 10ºC from the set point. Service Always a top priority with SANYO is a proper service and maintenance program. SANYO guarantees a quick response if there is ever a need. Technology features Quiet, Reliable Compressor SANYO freezers incorporate Cool Safe compressors. These in-house developed compressors are specifically designed for ULT freezers and ensure rapid pull down and uniformity for every model every time. Rechargeable Battery A rechargeable battery is built in as the backup battery for alarms. SAVE Energy The combination of efficient technology and construction bring the added benefit of considerable energy savings, freeing your funds for other purposes. Insulated Inner Doors SANYO s unique doors are fully insulated to provide better uniformity and guarantee an airtight seal. Two inner doors ensure that exposure to incoming air is kept to a minimum when the outer door is opened. VIP VIP (Vacuum Insulation Panel) Up to 35% more space by use of the patented Vacuum Insulation Panels (developed by SANYO). Power Failure Alarm The backup battery sounds the alarm in the event of power failure, AC interruption or other abnormalities. Note: Specifications can vary - please check individual model specifications for details. 3

7 SANYO Medical Life itself is our key customer - It is said that the 21st century is an age of biotechnology and the field of medicine is expected to make great strides at an accelerated pace. In order to offer products and services in these growth fields, which can secure customer confidence and satisfaction on a global scale, we must clearly understand the research themes and business objectives of our customers. SANYO Medical offers several unique patented technologies to optimize laboratory work in research, hospitals, pharmaceutical industry, food, plant technology and the biomedical field. dedicated Your SANYO enthousiastic 4

8 Life itself is our key customer SANYO has established a worldwide reputation as a manufacturer of highquality medical equipment over the past twenty-five years. In 1974 we introduced our first 40ºC chest freezer, followed in 1975 by our first automatic tablet dispensing systems for hospitals. Since then we have expanded our range to include pharmaceutical refrigerators, ovens, incubators, bio-clean rooms and plant growth chambers. One of our greatest achievements was the development in 1991 of the world s first 152ºC ultra-low temperature freezer. SANYO automatic tablet dispensing systems have had a major impact in the automation of hospital management and the separation of dispensary from medical practice. SANYO medical appliances can now be found all over North America, Europe and Asia, in particular South Korea, Hong Kong and Taiwan. SANYO is the only company in the market that can provide all the elements for its medical equipment from its own research and manufacturing resources, which cover everything from original refrigeration and electronics technologies to compressors and semiconductors. In 1993, SANYO led the world again as the first manufacturer to offer a complete range of HCFC-free medical equipment using original patented HCFC-free refrigerants, R-412a, R-509 and R-508 which were developed jointly with the UK company, ICI Chemicals & Polymers Ltd. In 1994 our factories received ISO recognition. In 1995 ultra low temperature freezer HFC refrigerant TP5R3 registered with ASHRAE as R-508A. In 1996 MIR- D30 authorized DNA amplifier. ISO 9001 obtained. In 1997 MDF-U70V 86ºC ultra low temperature freezer with Vacuum Insulation Panels. In 1998 vacuum chamber method automatic leak detection in refrigeration units. ISO obtained. SANYO E&E Europe BV Medical Division Biomedical Dental An experienced business unit that provides it s customers with high quality products, tailor made solutions and added value. They are proving to be a trustworthy and professional partner by creating an optimal European sales and service organisation. This business unit aims to become a recognizable leading specialist in Europe for dentists and dental related areas. Sterilisation, cleaning and service are the key words that characterizes this organization Healthcare To contribute to a healthier environment, SANYO s healthcare business unit developed the Virus Washer, which inactivates airborne viruses and bacteria. In addition to the Virus Washer, more healthcare related products will be introduced as from 09. Preservation system -152ºC/-135ºC/-86ºC ultra-low temperature freezers (MDF) -40ºC/-35ºC/-30ºC medical freezers (MDF) Blood bank refrigerators (MBR) Pharmaceutical refrigerators (MPR) General Purpose Laboratory Refrigerators (SRR) Freezers/refrigerators with totally reliable internal temperatures. Culturing system CO 2 incubators (MCO) Cooled incubators (MIR) Heated incubators (MIR) Plant growth chamber (MLR) Multi-cell imaging incubator (InCu-VIEW Live ) Incubators for advanced research and testing. Drying & sterilizing system Laboratory ovens (MOV) Dry heat sterilizers (MOV) Autoclave (MLS) Equipped with electronic control systems, these models limit temperature fluctuations Automated hospital pharmacy system Automatic tablet counting and packaging machine (ATC) Based on microcomputer advances, this unit enables accurate tablet dispensing and reduces operating costs. Medical & Laboratory Equipment 5

9 SANYO Service efficient Your SANYO purposeful Working side by side with our customers - At SANYO we appreciate how much your samples and products are worth to you. Your chosen equipment has been manufactured using world leading technology and specialist engineering, so it is important that we continue to provide the best support and care possible to maximise the potential and lifespan of your equipment. We have a dedicated team of SANYO Service Specialists who are trained to carry out repairs and service to our exacting standards, ensuring the support you need during the life of your equipment. Using our many years of experience and collaboration with our customers, we have designed a number of service options to suit your requirements and budget. During a Preventative Maintenance visit, using the latest technical information and recommended test equipment, our specialists will carry out extensive tests, and make any necessary adjustments to provide optimum performance. 6

10 Working side by side with our customers SANYO s Biomedical Business Unit has established a worldwide reputation as a manufacturer of high quality medical equipment over the past twenty five years. Together with the high standard of service we deliver, it makes us a major player in the biomedical market. Logically we want our SANYO dealers to offer you the same high standard of service that belong to our equipment. Therefore SANYO only works with dealers that do guarantee this quality. So whether you buy directly from us, or from one of our European distributors, you are always sure that maintenance will be done by SANYO certified service engineers. Which means that these engineers followed a step-by-step hands on training for all SANYO products. In this way SANYO guarantee their customers the best products with the best service! committed dedicated Dedicated Service Team focusing on SANYO Biomedical Products Comprehensive range of Preventative Maintenance Plans In Warranty Maintenance Free Technical Support Installation Commissioning Calibration Validation Repairs Fully equipped workshop Genuine SANYO spares 7

11 SANYO Synergy in Europe Synergy is the best policy - People all over the world in a variety of industries, recognize SANYO s products as innovative and of excellent quality. However our products are not always visible or recognizable. SANYO batteries for instance are world leading both in quality and quantity. But hidden in cell phones or electronic equipment, hardly anyone notices them! Superior quality is what all SANYO business divisions have in common. By combining this quality we create a synergy that will be profitable for you. In this way, we are able to offer you optimal business solutions; tailor made and service driven. SANYO is the natural choice for decision makers in Europe and beyond! teamplayer 8

12 How Synergy between divisions works for you! helpful Auditorium SANYO LCD Projection Energy SANYO Solar Laboratory equipment SANYO Medical Division example SANYO synergy in Universities Restaurant SANYO Food equipment Air Conditioning SANYO Air Conditioners Security SANYO CCTV reliable committed Your SANYO No matter what type of business you are in- from education to retail, from hospitals to hotels, whether blue chip company or bank or government department- you will find SANYO synergy exists between our Air Conditioning, Biomedical, CCTV, Food Equipment, Projector and Solar divisions. 9

13 SANYO s Brand Vision SANYO has taken a new step in becoming a leading provider of environmental and energy related products with a threefold approach, focusing on the environment, energy and lifestyle. In each of these fields, SANYO redefines conventional ideas and takes a radically new perspective in order to achieve our ultimate goal of preserving a beautiful earth for future generations. By combining our synergies in these fields, SANYO will provide a total solution to enable people to live in harmony with the Earth. SANYO is determined to create a compassionate and prosperous society. dedicated Your SANYO environmently conscious involved 10

14 Think GAIA SANYO will create products that both mankind and GAIA will treasure In the latter part of the last century, mankind s pursuit of convenience and material comforts has left behind indelible stains such as global warming and environmental destruction. It is time to listen to GAIA s voice. SANYO will develop products that both mankind and GAIA will treasure by holding fast to the concepts of sustainability and symbiotic evolution. Our aim is to restore a beautiful Earth for future generations by creating innovative solutions from our various resources. The results of our GAIA product development program can already be seen with the launch of many environmentally friendly products. For example as a world leader in solar cell technology we built the world s largest solar power generator to supply one of our production plants. We have used our battery technology to develop eneloop a rechargeable battery that s so efficient, it comes pre-charged and can be recharged about 1000 times. Not only that SANYO has developed a solar recharger so that the eneloop can be charged using the power of the sun. GAIA stands for the living Earth. Gaia stands for the living Earth. J.E. Lovelock who participated in NASA s Mars exploration program in the 1960s, proposed the idea of earth as a living, green organism where mankind and all living things live in harmony. He used Gaia, the name of the goddess Earth Mother in Greek mythology, to describe this living organism (Earth). The Earth has traditionally been viewed as the Earth or Globe. However, from now on, SANYO will view the Earth as an independent organic body and refer to it as Gaia. Washing machine with Air Wash A drum type washer/dryer that disinfects and deodorizes using Ozone* 1. The new Air Wash function changes the oxygen in the air to Ozone, thus enabling easy disinfection & deodorization. Another main feature of the revolutionary new washer/dryer is the Aqualoop function, which utilises Ozone to purify water, allowing it to be reused. SANYO Virus Washer technology There aren t many effective methods to suppress airborne bacteria, viruses and allergens, especially those that exist in large spaces. In order to solve this problem, SANYO has developed the Virus Washer air purification system, which suppresses and removes bacteria without the use of any chemicals. This system utilizes tap water, which is very accessible, with SANYO s proprietary electrolyzed water technology. The Virus Washer air purification system range includes products suitable for both home and commercial use. SANYO supplies the nickel-metal batteries used in hybrid cars such as Ford s Escape Hybrid and Honda's Accord Hybrid. A new product to replace dry cell batteries for the 21st Century eneloop is a product that proposes a new lifestyle one without disposing of batteries. Once charged, it can be used repeatedly, and once used completely, it can be recycled. To promote this new kind of battery lifestyle, SANYO developed the world s first rechargeable battery which can be used like a dry cell battery immediately after purchase. 11

15 SANYO Vision on Conservation Just like you, SANYO aims for the best result. Others may say today s standard is okay, but you know better. Thinking outside of the box, leads to remarkable results. You know that when you are really focused you can achieve anything. You and SANYO a perfect match. Innovation Our reputation is built upon world-class design and refrigeration systems developed specifically for ultra-low temperature applications. In fact, SANYO has pioneered the development of new technologies for ultra-low temperature storage from the -152 C freezer, the introduction of application specific CFC-Free refrigerants and the first -86 C freezer with Vacuum Insulation (VIP). innovative More recently SANYO introduced the next generation of compressors for ultra-low freezers. Cool Safe compressors provide new levels of durability with significantly reduced power consumption, heat output and noise. World Class Design Performance - SANYO refrigeration systems offer superior performance and durability, even in high ambient temperatures and in response to frequent door openings. The cooling system also maintains uniform temperatures throughout the freezer, which is especially important when validation is required C Ultra-low Freezers -86 C VIP Upright Freezers -86 C Chest and Upright Freezers Plasma Freezers -30 /-40 C Biomedical Freezers Inventory rack system Medical Pharmaceutical Refrigerators and Enviro-Centers SANYO Bio Secure Blood Bank Refrigerators Laboratory Refrigerators Isothermal Freezers Liquid Nitrogen Storage Low Frost Design - Fully insulated inner doors, advanced gasket design and heated door frames combat excessive ice build-up and ensure an effective seal against ambient air. This reduces routine maintenance and keeps samples safe. Vacuum Insulation (VIP) - SANYO was the first company to introduce vacuum insulation panels to ultra-low temperature freezers. The SANYO range of VIP freezers provide typically 25% more storage capacity for a given floor area saving valuable laboratory space. Sample Security - Advanced microprocessor controls constantly monitor freezer operation and ambient conditions to ensure reliable operation. Extensive audio-visual alarms and remote alarm contacts give immediate notice of a fault condition. Back-up and monitoring options are available. 12

16 The Heart of Ultra-Low Temperature Freezing Your SANYO dynamic focused creative Introducing the Next Generation Compressors: Cool Safe A wide range of Ultra-low temperature freezers. We ve selected a line-up of different types and models of ultra-low freezer which can achieve and maintain temperatures down to -152ºC. Designed to meet your needs SANYO ultra-low freezers are suitable for uses such as long term preservation, testing, frozen storage etc. Specially Designed Compressor for Ultra-Low Temperature. Evolving through continuous innovation; the reliability and performance of our specially designed ULT compressors has always been unmatched. Our ULT freezers are considered to be the top of the market all over the world. Where others would be satisfied with such performance, we are always searching for improvements. This resulted in developing the next generation of compressors: Cool Safe. The Cool Safe compressors achieve a 10% higher energy conservation and the aerodynamically designed and placed components in the refrigeration compartment provide superior airflow, making it possible to significantly reduce the stress to the freezer and contributing to excellent durability. Why change a winning team is a phrase that is often heard. We changed it to obtain even better performance. A compressor that produces less heat than before, a noise level even lower than before and a reliability and performance even more unmatched. We are the only ULT freezer manufacturer capable of developing our own compressors. This is what we do and we are good at it! 13

17 -152ºC Freezers MDF-1156 / MDF-1156ATN focused accurate The world of -152ºC Why freeze to 152 C? Recrystallization mechanism -80ºC Hexagonal crystal Achieves stable long-term preservation of cells and tissues. In preserving cells or tissues at ultra-low temperatures, the point is to prevent amorphous ice crystals from recrystalizing within and outside the cells. These ice crystals have smaller diameters than the smallest substances (4,000 to 7,000A) that compose cells or tissues. When ice crystals become amorphous, they are stored using cryoprotective agents such as glycerine and dimethyl sulfoxide (Me 2 SO). The speed of ice crystal formation is thus further restricted during preservation below a certain temperature, and complete vitrification is possible C is the recrystallization point of pure water in the ultra-low temperature zone. This is the temperature at which amorphous ice crystals recrystallize. SAVE -130ºC Recrystallization Point -152ºC Cubic crystal Amorphous ice crystal For a mixed solution containing Me 2 SO and other cryoprotectants, recent research confirms that recrystallization occurs around -115ºC. Thus samples maintained in an ultra-low temperature freezer at -152º C, far lower than the recrystallization point, can be semi-permanently preserved. Such preservation maintains vitrification without further crystallization within and outside cells. Other recent findings show that preserving cattle sperm at -135 C is insufficient, and also that superconductivity experiments require temperatures of at least -148ºC. These cases show the increased necessity of -152ºC freezing. 14

18 stable Your SANYO Until recently, liquid preservation containers were mainly used when preserving valuable samples over long periods. This method however, involved troublesome liquid control and the dangers of a liquid supply. In addition, mycoplasma etc. could cause cell and tissue contamination in liquid phase preservation. As a solution to this problem, demand for vapour phase preservation has increased. In preservation with liquid nitrogen vapour, temperatures can rise to approximately -150ºC, almost the same as the ultralow temperature freezer s inner cabinet temperature of -152ºC. And freezer preservation provides users with numerous advantages; no worries about sample contamination, no liquid supply problems, no danger of sudden liquid eruptions, and low operational costs. This freezer provides easier and more stable long-term storage below the recrystallization point than ever before. Features HCFC-Free special mixed refrigerant SANYO has developed a special mixed refrigerant, replacing chlorofluorocarbons (HCFCs) that deplete the ozone layer. This new cooling system virtually eliminates damage to the earth s environment. Specially designed compressor and cascade refrigeration system for an ultra-low temperature of -152ºC A highly efficient, exclusive compressor has been specially developed and incorporated in the freezing unit. A refrigeration circuit with the Cool Safe compressor cascade refrigeration system enhances reliability of long-term preservation. With a powerful low noise design afforded by traditional ultra-low temperature technology, this freezer delivers durable, stable cooling. Microprocessor temperature control with LED digital display allows accurate temperature control Accurate temperature setting, confirmation and operation are all possible through microprocessor temperature control with a LED digital display and flat key data entry. The world s first electronically controlled freezer, this model maintains inner cabinet temperature at an ultra-low -152ºC (ambient temperature of 30ºC), far lower than the recrystallization point for pure water (-130ºC). This low temperature provides an ideal preservation environment for long-term storage. High-efficiency oil separator for stable ultra-low temperature environments Compressors continuously repeat highly compressed operations, so lubricant oil is essential to prevent abrasion and seizure. But when lubricant oil circulates in the refrigeration circuit, piping becomes clogged and results in compressor damage. Incorporating an exclusive highefficiency oil separator, the MDF-1156 effectively separates lubricant oil from refrigerant, offering a stable ultra-low temperature environment. Special foamed-in-place polyurethane insulation material The temperature difference between the inside and outside of the MDF-1156 unit reaches a maximum of 182ºC. In the ultra-low temperature range below -100ºC, ordinary foamed-in-place polyurethane insulating material can become cracked and warped. Specially designed to withstand low temperatures, SANYO s foamed-in-place polyurethane is 170 mm thick and highly resistant to extreme temperature differences, thus helping maintain inner temperature stability. Various alarm and safety devices for protecting valuable samples Microprocessor-controlled filter-clogged check function protects the refrigeration circuit. High temperature warning equipment automatically indicates when the temperature deviates 15ºC from the set temperature. The power failure alarm lamp and buzzer are activated in case of power failure or irregular temperature increase. A remote alarm contact is fitted. ATN models are also equipped with an auxiliary back-up system for liquid nitrogen. Inner cabinet s easy-to-use design Accommodates world standard 2 and 3 boxes. 15

19 -152ºC Freezers MDF-1156 / MDF-1156ATN Dimensions Specifications Unit: mm 945 Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Door Inner lid Insulation Exterior Interior Outer door latch Outer door lock Casters Access port Weight Cooling performance Refrigeration circuit Compressor Oil separator Refrigerant Refrigerating oil Evaporator Condenser Power supply MDF-1156/1156ATN 1400 x 800 x 945 mm 500 x 450 x 572 mm 128 litres 1 door, Painted steel, Acrylic finish baked 1 lid Rigid polyurethane foam in place (HCFC Free) Acrylic finish baked on painted steel Aluminium (Alumite treated) 1 pc 1 pc (latch integrated lock) 6 pcs (leveling leg 2pcs) 1 *Left side (Dia. 40mm) Approx. 285 kg -152ºC (AT 30 C, Inner air temp.1/2h) Secondary cooling system High stage side : 1100 W (hermetic type) Low stage side : 1100 W (hermetic type) SPK-0S02S2 High stage side : HFC refrigerant (R407D+6pt) Low stage side : HFC mixed refrigerant Ze-NIUS22SA High stage side : Cascade condenser Low stage side : tube on sheet type (Interior and exterior) High stage side : Fin and tube condenser Low stage side : Cascade condenser Local voltage *Single phase 2V, 50/60Hz *Single phase 230V, 50Hz *Single phase 240V, 50Hz reliable accurate * The back-up system does not include container for liquid nitrogen. Required for the ATN model. MDF-1156 has no recorder. * Specifications subject to change without notice. Applications Preservation Cancer research: Tumor Cell Preservation Blood or Bone Marrow Preservation Bacteria Research: Virus Preservation Sperm & Fertilized Ovum (Bull, Goat, Horse, Pig, Chicken) Preservation Plant Cell Preservation (ie. Pollen) Monoclonal Antibody Preservation Environmental Experiment Superconductivity & Electronics Experimentation (-148ºC) User University Private Institute Public Research Center Hospital 16

20 Specifications / Function Temperature controller Temperature sensor Temperature indication Alarm Temperature alarm Filter alarm Power failure alarm Remote alarm Controller Self-diagnostic function Power switch Compressor protection function Microcomputer control system : keypad input Temperature setting range : from -125 to -155 C (set by 1 C) Setting value memory : non volatile memory Pt LED display (1 C increments) Temperature setting +15 C (default) or +10 C selectable ALARM lamp flashes and intermittent buzzer sounds (15 min. of delay) Remote alarm interface : Normal/Open, Normal/Close Interface rating DC30V, 2A Temperature alarm turns ON during power failure Alarm ring back function (OFF: 0, 10-60: by the minute) FILTER check lamp flashes, intermittent buzzer sounds Evolution ALARM lamp flashes and intermittent buzzer sounds, Remote alarm operates Remote alarm terminal 3P : DC30V, 2A NC-COM, NO-COM (Output at temperature alarm or power failure alarm) Lamp: ALARM, FILTER, BACK-UP Display: LED BUZZER : buzzer stop key ALARM TEST : alarm test key SET : to switch the setting value and the inner temperature > : to shift the setting digit > : to change the setting value ENT : entry key Battery SW (Shared power supply SW for MDF-1156/1156ATN) Remote alarm contact ON/OFF switch Back-up injection test switch Back-up ON/OFF switch When either the temperature sensor, filter sensor, cascade sensor, A.T. sensor is faulty, error code and inner temperature is alternately displayed and remote alarm interface operates and intermittent buzzer sounds. Breaker switch * Cascade sensor L-Compressor turns ON at under -24 C L-Compressor turns OFF at over -10 C * Overload relay and H-Compressor control (Pressure SW substitution function) * Specifications subject to change without notice. Options LCO 2 backup system LN 2 backup system with recorder CVK-A (MDF-1156) CVK-ATN2 (MDF-1156) Performance data MDF-1156 / MDF-1156ATN Pull-down characteristics Temp. distribution inside cabinet -150ºC setting,ambient temperature 35ºC, no load Temperature chart recorder (-170ºC to +30ºC ) MTR-155H Chart paper RP-155 Ink pen DF-38FP Storage case MDF-49SC Inventory racks see page 46 Effect of ambient temp. on holding time of liquefied gas at: ºC low-temp. side operation rate 72% ON: 10min OFF: 4 min Pull-up characteristics during power failure Effect of ambient temp. on inside temp. 17

21 -150ºC Freezer MDF-C2156VAN The world s largest capacity -150 C freezer SAVE Ultra-low -150ºC freezer with third generation VIP insulation. The freezer is equipped with SANYO developed third generation Vacuum Insulation Panels. This improved VIP insulation is extremely efficient and results in a -150ºC freezer with a capacity of 140 world standard 2 boxes, the largest capacity -150ºC freezer in the world! New control panel with graphic LCD display All the alarm functions, self-diagnostic notifications and a digital graph of the temperature are available in the new, specially designed LCD display. The blue display provides a clear image of the temperature and gives a notification in the case of abnormalities in temperature, ambient temperature, power supply etc. New Cool Safe compressors The MDF-C2156VAN is equipped with the new Cool Safe compressors. The compressors achieve a 10% higher energy conservation and the aerodynamically designed and placed components in the refrigeration compartment provide superior airflow, making it possible to significantly reduce the stress to the freezer and contributing to excellent durability. New double door gaskets The temperature difference between the inside of the cabinet and the ambient temperature can be up to 180ºC! To prevent leaking the MDF-C2156VAN is equipped with a new double door gasket. Environmentally friendly The MDF-C2156VAN utilises binary mixed non-hcfc refrigerants. The new Vacuum Insulation Panels and double door gaskets reduce the power consumption. 18

22 Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Outer door Inner door Insulation Exterior material Interior material Outer door latch Outer door lock Casters Monitoring hole Cooling performance Refrigeration circuit Compressors Oil separator Refrigerant Refrigerant oil Evaporator Condenser Net weight Power supply Accessories MDF-C2156VAN 1730 x 765 x 1010 mm 760 x 495 x 615 mm 231 litres 1 door, Zinc galvanized steel with baked on acrylic paint (NB gray), 2 hinges 2 pcs, Plastic and insulated Rigid Polyurethane foam + new VIP (Vacuum Insulation Panels), HCFC free Zinc galvanised steel with baked on acrylic paint (NB gray) Aluminium plate 1 pc 1 pc 6 pcs 1pc (Dia. 40mm) -150ºC (AT30ºC, at 1/2 of chamber, air temperature) Binary cascade + Low side auto cascade refrigeration system High side: 1100W (hermetic type) Low side: 1100 W (hermetic type) SPK-OS02S3 High side: HFC refrigerant (R407D + 6pt) Low side: HFC refrigerant (Non-azeotropic mixed refrigerant ) Ze-NIUS32SA High side: Cascade condenser Low side: Tube on sheet (shared with interior) High side: Fin and tube condenser Low side: Auto cascade condenser Approx. 319 kg Local voltage 2 sets of keys, 1 scraper innovative Your SANYO * The back-up system does not include container for liquid nitrogen. * Specifications subject to change without notice. ambitious Specifications / Function Temperature controller Temperature display Control panel Remote alarm Alarms Temp. alarm Filter alarm Power failure alarm Status function Logging function Self-diagnostic function Key lock function Temperature sensor Power switch Compressor protection function Back-up equipment Micro computer, Settable temperature range: -125 to -155ºC (1ºC increment) Set value memory: Non-volatile memory LCD panel Temperature : Digital display (1ºC increment) : Graphic display (Chamber temperature for 24h is displayed on 1 screen) Time : year-month-day, hour-minutes-second (keep moving by lithium battery during power failure) Alarm lamp (Red), Back up (Green), BZ key(for buzzer stop), CE key (for cancel) 0,1,2,3,4,5,6,7,8,9 key, _,_,_,_ key MENU key, ENTER key Remote alarm terminal 3P : DC30V, 2A N.C.-COM., N.O.-COM (for temp./sensor abnormality, power failure alarm) Set temperature +/-5 to +/-ºC, variable (default setting +/-10ºC ) Flash of alarm lamp and inversion/noninversion of chamber temperature (on LCD panel) Intermittent buzzer (15 min. delay) Remote alarm contact: Normal open, Normal close Contacting rating DC30V, 2A (after 15min. delay) contact inversion Flash of ALARM lamp and inversion/noninversion of alarm message on LCD panel. Intermittent buzzer (Remote alarm terminal is not activated) Flash of ALARM lamp, Intermittent buzzer, and Remote alarm contact Inversion/noninversion of alarm message on LCD panel Battery / Fan motor replacement will be informed. Power supply abnormality: out of rated value +/-10% Ambient temperature abnormality: 0_A.T. sensor temperature _35ºC Fan motor abnormality Over load operation Record month/week chamber temperature Record outer door opening (more than 2 min.) Record temperature of cascade sensor, filter sensor, and ambient sensor Ability to transfer log to PC (optional communications interface) When one of the following sensors is abnormal, error code and status message will be displayed. Temperature sensor Filter sensor Cascade sensor Ambient temperature sensor Flash of ALARM lamp, activate remote alarm contact(non-voltage), Intermittent buzzer Change chamber temperature non-available Inside of MENU (KEY LOCK) 0: Lock released 1: Locked Pt 1000 Breaker switch (15A) Cascade sensor: Low compressor ON at lower than -34ºC, Low compressor OFF at higher than -12ºC Overload relay and high pressure SW in low side With electric temperature controller (temperature sensor Pt1000) Specifications of back-up controller, Temperature set value, AN : dialer(setting range: -105ºC to -135ºC) Indicator lamp : Back-up (green), Back-up test switch : push switch, Power switch : locker switch 19

23 -150ºC Freezer MDF-C2156VAN Dimensions Unit: mm Options Temperature chart recorder (-170ºC to +30ºC) MTR-155H Chart paper RP-155 Ink pen DF-38FP Mounting kit MDF-S30150 Storage case MDF-49SC Inventory racks see page 46 Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 Performance data MDF-C2156VAN Pull-down characteristics Temperature ( C) 40 Central air temp. in cabinet 0 Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Time (hour) Temperature ( C) Time (hour) LN 2 back up system operation characteristics Ambient temp. and maintenance of 135 C by injection of LN 2 (50kg) Ambient temperature ( C) 55,000 tons it s the estimate that SANYO Solar Cells produced in 06 are yielding an annual reduction of CO 2 roughly equal to 55,000 tons environmently conscious Vision

24 -86ºC Freezers MDF-U33V / MDF-U53V / MDF-U73V winner secure VIP Your SANYO Ultra-Low temperature V.I.P. Freezer Maximised storage capacity with V.I.P. technology Safe operation with continuous condition monitor Status Alert Enhanced security Improved accessibility Ergonomic quiet operation SAVE Which freezer will you choose? V.I.P. (Vacuum Insulation Panel) VIP panel is the innovative insulation component developed and manufactured by SANYO. VIP panels contain densely packed, open cell foam insulation under vacuum. This configuration dramatically enhances the insulation capability of the freezer while reducing the wall thickness. This in turn provides greater interior volume and structural stability. Conventional Insulation SANYO MDF-U53V With VIP Insulation 240 ca. 352 ca. Capacity 2 boxes 2 boxes Insulation 21

25 -86ºC Freezers MDF-U33V / MDF-U53V / MDF-U73V MDF-U73V 728 LITRES BOXES BOXES accurate What makes our V.I.P. Ultra-low freezer special? New design Evolution and Revolution SANYO V.I.P. Evolution Series -86ºC ultra-low temperature freezers use patented revolutionary Vacuum Insulation Panels (VIP) that reduces the wall thickness from 14cm to 7cm and achieves up to 30% more storage capacity than a conventionally insulated freezer without increasing the footprint. This series also combines various cutting edge technologies to evolve and enhance user convenience. Temperature check Reliability Status Alert (Condition monitor) Monitors ambient and system conditions continuously and notifies of any abnormalities before a problem happens. Safe Storage Super cooling technology with alarm systems ensures accurate storage conditions. Insulated inner doors prevent cool air leakage. Security Along with a standard door lock, the new rugged outer door latch has a hole to allow a padlock to securely protect valuable samples. make opening and closing the door smoother. Large Control Panel Multiple Inner Doors (Option) Field-installable insulated multiple inner doors enhance user flexibility. Set of 2 doors. Up to 2 sets can be installed. Door check Filter check Accessibility Eagle Latch A new beak style inner door latch tightly closes the inner door against the freezer frame. It also helps 22

26 MDF-U53V 519 LITRES BOXES BOXES winners MDF-U33V 333 LITRES BOXES BOXES Alarms & Safety functions Alarm & Safety Situation Indication Buzzer Safety operation High temperature alarm If the chamber temperature is higher than the temperature at which the high temperature alarm is activated. Alarm lamp flashes. Temperature indicator is flashed. Intermittent tone with 15 minutes delay. Remote alarm with 15 minutes delay. Low temperature alarm If the chamber temperature is lower than the temperature at which the low temperature alarm is activated. Alarm lamp flashes. Temperature indicator flashes. Intermittent tone with 15 minutes delay. Remote alarm with 15 minutes delay. Power failure alarm When the power to the unit is disconnected. Alarm lamp flashes. Intermittent tone. Remote alarm. Filter check When the condenser filter is clogged. Filter check lamp lights Auto-return When there is no key pressing in each setting mode for 90 seconds. Chamber temperature is displayed. --- Finishing of each setting mode. Sensor abnormality If the thermal sensor is disconnected. Alarm lamp flashes. E01 and chamber temp. are displayed alternately. Intermittent tone. Unit keeps running. Remote alarm. If the thermal sensor is short-circuited. Alarm lamp flashes. E02 and chamber temp. are displayed alternately. Intermittent tone. Unit keeps running. Remote alarm. If the cascade sensor is disconnected. Alarm lamp flashes. E03 and chamber temp. are displayed alternately. Intermittent tone. Unit keeps running. 23

27 -86ºC Freezers MDF-U33V / MDF-U53V / MDF-U73V Performance data MDF-U33V Pull-down characteristics Temperature ( C) 40 Central air temp. in cabinet 0 Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Temperature ( C) Time (hour) CO 2 backup system operation characteristics Time (hour) Ambient temp. and maintenance of 70 C by injection of LCO2 (30kg) Ambient temperature ( C) Performance data MDF-U53V Pull-down characteristics Temperature ( C) Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Time (hour) Temperature ( C) CO2 backup system operation characteristics Time (hour) Performance data MDF-U73V Pull-down characteristics Time (hour) Pull-up characteristics during power failure Dimensions Ambient temp. and maintenance of 70 C by injection of LCO 2 (30kg) Ambient temperature ( C) Temperature ( C) 40 Central air temp. in cabinet Ambient temp. 30 C, No-load Temperature ( C) CO 2 backup system operation characteristics Ambient temp. and maintenance of 70 C by injection of LCO2 (30kg) Time (hour) Ambient temperature ( C) Time (hour) Front Compressors Back cover Rear Air The newly developed back cover combined with new aerodynamically designed and placed components in the refrigeration compartment provide superior air flow, making it possible to drastically reduce the stress on the freezer and contributing to excellent durability MDF-U73V MDF-U53V MDF-U33V Unit: mm 24

28 Specifications Model MDF-U33V MDF-U53V MDF-U73V Exterior dimensions (W x D x H) 670 x 867 x 1860 mm 770 x 875 x 1990 mm 1010 x 875 x 10 mm Interior dimensions (W x D x H) 490 x 600 x 1140 mm 630 x 600 x 1380 mm 870 x 600 x 1400 mm Effective capacity 333 litres 519 litres 728 litres Outer door 1 door, Acrylic finish baked (NB. Grey) Inner door 2 doors (Rigid polyurethane foam insulation) HCFC Free Insulation Rigid polyurethane foam + VIP (Vacuum insulation panel) HCFC Free Exterior Acrylic finish baked on painted steel (NB.Grey) Interior Acrylic finish baked on painted steel (S White) Shelf 3 shelves, Stainless steel Outer door latch 1 pc Outer door lock 1 pc Caster 4 pcs (levelling leg 2 pcs) Access port 3 locations Upper backside (ø17mm) for a back-up nozzle Right side bottom (ø17mm) for validation Left side bottom (ø17mm) for a recorder sensor Weight Approx. 255 kg Approx. 299 kg Approx. 350 kg Cooling performance -86 C (AT 30 C, Inner air temp.1/2h) Refrigeration circuit Cascade cooling system Evaporator High stage side :Cascade condenser Low stage side :Tube on sheet type (Interior and exterior) Condenser High stage side :Fin and tube condenser Low stage side :Cascade condenser Temperature controller Microcomputer control system: keypad input Temperature setting range : -50 ~ `-90 C (set by 1 C) Setting value memory : non-volatile memory Temperature sensor Pt Temperature indication LED display (1 C resolution) Alarms: Temperature alarm Audible & Visible indication Door alarm Audible & Visible indication Filter alarm Audible & Visible indication Power failure alarm Audible & Visible indication Remote alarm Yes Part replacement notification Visible indication Status function Visual indication Self-diagnostic function Audible & Visible indication Key lock function Yes Power switch Breaker switch Compressor protection function Yes Standard Voltage 230/240V HZ 50 Hz Phase 1 AMPS - Breaker 15 A Temperature display Digital display, Door mounted Accessories Key 1 set, Scraper 1 pc Refrigerant HFC *Appearance and specification are subject to change without notice. Options LCO 2 backup system LN 2 backup system Circular temperature chart recorder (-100ºC to +40ºC) Chart paper Ink pen Temperature chart recorder (-100ºC to +50ºC) Chart paper Ink pen Recorder housing (for MTR-85H) Data Acquisition System (DAQ) Interface Software CVK-UB2 CVK-UBN2 MTR-G85 RP-G85 PG-R MTR-85H RP-85 DF-38FP MDF-S3085 MTR-480 MTR-00 3 drawers for MDF-U53V MDF-50R 3 drawers for MDF-U33V MDF-30R 1 set of 2 inner doors for MDF-U53V MDF-5ID 1 set of 2 inner doors for MDF-U73V MDF-7ID Inventory racks see page 47 25

29 -80ºC Freezers MDF-C8V1 flexible Your SANYO personal VIP MDF-C8V1 84 LITRES -80 C Ultra-Low Temperature V.I.P. Freezer New V.I.P. PLUS technology maximises storage capacity Filterless structure makes cleaning unnecessary Low noise design Achieves energy savings of approx. 40%* * SANYO Comparison SAVE Conventional model* MDF-C8V1 Features Capacity 86L Capacity 84L More advanced insulation system: V.I.P. PLUS SANYO s more advanced insulation system V.I.P. PLUS enables reducing the thickness of insulation to approximately one half compared to conventional systems. Small freezers such as MDF-C8V1 takes full advantage of this feature. Use of V.I.P. PLUS insulation material on the front, left, and right sides enables a smaller installation space with the highest class storage capacity ratio. *SANYO comparison Installation space m m 2 2 New cooling circuit enables filterless structure A new cooling circuit makes the inconvenient customer maintenance procedure of filter cleaning unnecessary. 26

30 Specifications Model Temperature range Maximum cooling performance Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Net weight Outer door/inner door Insulation Cooling system Compressor Refrigerant Evaporator Alarm system MDF-C8V1-60 to -80 C (1 C increments) -80 C (Ambient temp. 30 C) 550 x 685 x 945 mm 405 x 490 x 425 mm 84 litres Approx. 67 kg Outer Lid: 1piece, Inner Lid: 1piece (PS + PE foam) New VIP + Rigid polyurethane foam New mixed refrigerant cooling system Rotary type, Output: 400W HFC Tube on sheet type High/Low temp. alarm (±5 C to ± C) Power failure alarm Remote alarm contact: DC30V, 2A *Appearance and specifications are subject to change without notice. *Cooling performance is indicated by the temperature reached at the center of the freezer (at ambient temperature of 30 C with no load). In order to use the freezer at a stable temperature for a long time, it is recommended that the temperature be set to at least 5 C higher than the indicated lowest temperature. In addition, depending on the usage conditions, it may not be possible to reach the indicated lowest temperature. Options Dimensions LCO 2 backup system CVK-UB4 LN 2 backup system CVK-UBN2 Mounting plate for CVK-UB4 MDF-UBK Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85 Chart paper RP-G85 Ink pen PG-R Temperature chart recorder (-100ºC to +50ºC) MTR-85H Chart paper RP-85 Ink pen DF-38FP Recorder housing (for the MTR-85H) MDF-S3085 Recorder sensor cover MTR-C8 Inventory racks see page MDF-C8V1 Unit: mm Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 Newly developed single-compressor system Use of a newly developed single-compressor system achieves an approximately 40% reduction in power consumption and enables low-noise operation. Rated power consumption MDF-C8V1 340W/330W Conventional model* 550W/600W *SANYO comparison (115V, 60Hz/230V, 50Hz) Performance data MDF-C8V1 Pull-down characteristics Temperature ( C) Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Time (hour) Temperature ( C) CO 2 backup system operation characteristics Time (hour) Ambient temp. and maintenance of 70 C by injection of LCO 2 (30kg) Ambient temperature ( C) 27

31 -86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S Your SANYO reliable ambitious Ultra-low temperature upright freezers -86ºC SANYO offers a wide range of upright -86 C freezers to suit your individual storage needs. All our freezers feature the usual high-quality components you would expect from SANYO including HCFC-free refrigerants. All units feature full alarm systems to ensure your samples are well protected and secure. SANYO freezers ultilise a cascade cooling system, enabling ultra-low freezer temperatures to be reached quickly and quietly. Microprocessor control maintains these temperatures accurately and reliably. Low-temperature range applications Potential users Blood Animal & Plant Tissue Micro- Drugs Industrial organisms equipment SAVE Universities Private enterprises, Pharmaceutical companies Medical institutions, Hospitals Public research centres, research institutes 0 C -10 C - C -30 C -35 C -40 C -50 C -86 C Plasma Quick plasma Freezing Red cell Platelets Lymph cells Granulocytes Enzymes Skin cells Internals Organs DNA Embryos Cornea Bone marrow Roots Seeds Pollen Cells DNA Cells Yeast Micro organisms Virus Drugs Blood Serum vaccines For industry Equipment & Electronic parts 28

32 MDF-U5386S 483 LITRES 3 2 BOXES BOXES MDF-U7386S 668 LITRES BOXES BOXES Dimensions Unit: mm 29

33 -86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S MDF-U3386S 333 LITRES BOXES BOXES Your SANYO MDF-U3386S Unique design and size targets the growing trend to personal freezers and compact size. While this is a spacesaver there is no compromise on features. Easy access and quick placement or locating of samples. The foamed-in-place rigid polyurethane insulation is HCFC-free as in all other SANYO freezers. Features all of the technology, construction and reliability you have come to expect from SANYO freezers. Simplified maintenance with easy access filter. Less formation of ice. Specifications Model MDF-U3386S MDF-U5386S MDF-U7386S Exterior dimensions (W x D x H) 750 x 875 x 1850 mm 890 x 875 x 1990 mm 1130 x 875 x 1990 mm Interior dimensions (W x D x H) 490 x 600 x 1140 mm 630 x 600 x 1280 mm 870 x 600 x 1280 mm Effective capacity 333 litres 483 litres 668 litres Net weight Approx. 255 kg Approx. 305 kg Approx. 355 kg Temperature range -50 C to -86 C (1 C increment) Maximum cooling performance -86 C (Ambient temp. 30 C) Shelves 3, Stainless steel, Adjustable, Max. load 50 kg Acces port 17 mm diameter, 3 locations (back, bottom, left/right corner) Compressor Hermetic type, Output: high stage 450W, Hermetic type, Output: high stage 1100W, low stage 1100W low stage 750W Refrigerant High stage: R-404A (HFC), Low stage: High stage: R-407D (HFC), Low stage: R-508 (HFC) R-508 (HFC) Alarm High/low temperature, Power failure, Filter check, Battery check, Part replacement notification Remote alarm contact Allowable contact capacity: DC 30V, 2A 30

34 Front Compressors Back cover Rear Air The newly developed back cover combined with new aerodynamically designed and placed components in the refrigeration compartment provide superior air flow, making it possible to drastically reduce the stress on the freezer and contributing to excellent durability. Options innovative LCO 2 backup system LN 2 backup system Circular temperature chart recorder (-100ºC to +40ºC) Chart paper Ink pen Temperature chart recorder (-100ºC to +50ºC) Chart paper Ink pen Recorder housing (for MTR-85H) CVK-UB2 CVK-UBN2 MTR-G85 RP-G85 PG-R MTR-85H RP-85 DF-38FP MDF-S3085 ambitious Data Acquisition System (DAQ) Interface MTR-480 Software MTR-00 Inventory racks see page 47 Performance data MDF-U3386S Temperature ( C) Pull-down characteristics 40 0 Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Temperature ( C) CO 2 backup system operation characteristics Ambient temp. and maintenance of 70 C by injection of LCO2 (30kg) Time (hour) Ambient temperature ( C) Time (hour) 10 Performance data MDF-U5386S Temperature ( C) Pull-down characteristics 40 0 Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Temperature ( C) Time (hour) CO 2 backup system operation characteristics 14 Time (hour) Ambient temp. and maintenance of 70 C by injection of LCO 2 (30kg) Ambient temperature ( C) Performance data MDF-U7386S Temperature ( C) Pull-down characteristics 40 Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Pull-up characteristics during power failure Temperature ( C) CO 2 backup system operation characteristics Ambient temp. and maintenance 80 2 of 70 C by injection of LCO 2 (30kg) Time (hour) Ambient temperature ( C) Time (hour) 31

35 -86ºC Freezers MDF-U4186S MDF-U4186S Advanced refrigeration system Quiet operation Enhanced security Removable inner doors for cleaning and defrosting Evolutionary design The newly developed refrigeration system and the freezer structure offer a quiet experimental environment. The newly developed back cover combined with new aerodynamically designed and placed components in the refrigeration compartment provide superior airflow, making it possible to drastically reduce the stress to the freezer and contributing to excellent durability. Two independent and insulated inner doors prevent cold air leakage. Accessibility The condenser filter is situated at the bottom right side of the front panel to make filter removal and cleaning easier. MDF-U4186S 382 LITRES BOXES Options LCO 2 backup system LN 2 backup system Temperature chart recorder (-100ºC to +50ºC) Chart paper Ink pen Recorder housing (for the MTR-85H) CVK-UB2 CVK-UBN2 MTR-85H RP-85 DF-38FP MDF-S3085 Data Acquisition System (DAQ) Interface MTR-480 Software MTR-00 Inventory racks see page 47 Specifications Model Temperature range Maximum cooling performance Exterior dimensions (W x D x H) Interior dimensions (W x D x H) MDF-U4186S C to 86 C (1 C increment) 86 C (Ambient temperature 30 C) 870 x 780 x 1975 mm 6 x 515 x 10 mm Performance data MDF-U4186S Temperature ( C) Pull-up characteristics during power failure Time (hour) Temperature ( C) Pull-down characteristics 40 Central air temp. in cabinet Ambient temp. 30 C, No-load Time (hour) Dimensions MDF-U4186S Net weight Effective capacity Shelf Access port Compressor Refrigerant Approx. 281 kg 382 litres Stainless steel, Adjustable, 3 shelves 40 mm diameter, 1 location (left side) Hermetic type, Output: 1100 W (high stage side), 1100 W (low stage side) HFC refrigerant Time (hour) CO 2 backup system operation characteristics Ambient temp. and maintenance of 70 C by injection of LCO2 (30kg) Alarm High temperature, Power failure, 32 Remote alarm contact Accessories Filter check, Part replacement notification Allowable contact capacity: DC 30V, 2A 1 set of keys, 1 scraper Ambient temperature ( C) 62 Unit: mm

36 The heart of the Chest type freezers SANYO s Ultra-Low Temperature Chest freezers combine innovation with superior performance and reliability. Ideal for maintaining stable internal temperatures, the secure chest design is enhanced by super-efficient freezing technology and advanced features. Freezer capacities range from economical to bulk, allowing you to maximize your long-term preservation and storage environment. You and SANYO a perfect match. An Ideal Freezing Environment By Means of Foamed-in-place Insulation and the Hot Line. In Ultra-Low temperature freezers, effective insulation is extremely critical since the temperature difference between the outside and the inner compartment can be as high as 115ºC. The insulation used in SANYO s ultra-low temperature chest freezers is highly efficient rigid, foamed in place polyurethane. Moisture condensation at the top edges of the cabinet due to differences in temperature inside and out causes frost and icing problems, which may reduce heat insulation efficiency and obstruct lid movements. They are prevented by the hot line by means of which hot gas from the higher temperature circuit is circulated through the problem areas. A Special Refrigerant and Oil to Maintain Stability and Reliability. In order to expand refrigeration capacity, a special compound refrigerant has been used. This refrigerant relieves the refrigeration system of much of its load by evaporating at a lower temperature level within the circuit. Also, a special grade of refrigeration machine oil is used with the superior properties of high rate of recovery and outstanding resistance to heat and wear. This contributes to the long life and dependability of the freezer unit as a whole. Microprocessor Temperature Control with Digital Design. Precise setting and control is possible. The temperature inside the freezer can be set and monitored easily by means of very accurate microprocessor temperature control with digital display. The controller utilizes a platinum resistor (Pt 100) sensor which is precise and extremely durable. Built-In Temperature & Power Failure Alarms (Lamp/ Buzzer). Protecting Contents from Trouble. In case of power failure or an irregular rise in temperature, a rechargeable, battery-operated indicator lamp and alarm will be activated. Optional recorders automatically record the inside temperature and an accessory LCO 2 back-up system is self-activated when the freezer temperature increases. This equipment helps ensure that the contents will be protected in the event of any power failure or mechanical trouble. Innovative Design Easy to Operate. Overall operability and dependability are greatly enhanced by improved design details. Highly durable hinges are used to support the lids so both opening and closing are facilitated. Lid handles are equipped with a latch-locking system, and the control panel is protected from accidental setting. Foamed polystyrene Glass wool Rigid foamed urethane 33

37 -86ºC Freezers MDF-794 / MDF-594 / MDF-393 / MDF-192 Your SANYO personal precise Ultra-low temperature chest type freezers -86ºC A wide range of ultra-low temperature freezers to suit your needs from bulk preservation to personal in-lab use. Ideal -86ºC freezing environment. Specially designed Cool Safe compressors for ultra-low temperature. Microprocessor temperature control with digital design for precise setting and control. Built-in temperature and power failure alarms (lamp/buzzer). SAVE These ultra-low temperature freezers are designed by SANYO to maintain internal temperature as low as -86ºC, at an ambient temperature of +30ºC. They are ideally suited for use in hospitals and laboratories, in long-term preservation and storage of blood, specimens and components, and in testing of various types. Ranging in size from economical chest freezer to large-capacity, one of these models is sure to be suitable for your needs. Advanced features include a microprocessor temperature control system with digital temperature display, a platinum resistance sensor for extra precision and reliability, a power failure warning system with built-in audible and visible indicators, and easyopen/easy-close hinged lid. 34

38 MDF LITRES Performance data MDF-794 Pull-down characteristics under no-load condition Temp. ( C) Central air temp. in cabinet Ambient temp. 30 C, no load Time (hr.) Pull-up characteristics during power failure Temp. ( C) Central air temp. in cabinet Ambient temp. 30 C, no load Time (hr.) Time (hr.) Effect of ambient temp. on holding time of liquefied gas SV of backup system 70 C LCO 2 30kg Ambient temp. ( C) 35 Dimensions 861 Performance Type Cooling performance Control range Recording range MDF-794 MDF-594 MDF-393 MDF-192 Centre part of freezing room -86ºC. ambient temperature 30ºC -ºC to -86ºC + 50ºC to -100ºC (with optional MTR-85H recorder) 105 MDF-794 Unit: mm 1 Power switch 2 Back-up system switch (option) 3 Back-up system test switch (option) 4 Remote alarm switch 5 Temperature setting key 6 Digit shift key 7 Figure shift key 8 Entry key 9 Alarm test key 10 Buzzer key 11 Alarm lamp and buzzer 12 Filter clog check lamp 13 Temperature display 14 Temperature recorder (option) 35

39 -86ºC Freezers MDF-794 / MDF-594 / MDF-393 / MDF-192 MDF LITRES Performance data MDF-594 Pull-down characteristics under no-load condition Central air temp. in cabinet 0 Ambient temp. 30 C, no load Time (hr.) Temp. ( C) Pull-up characteristics during power failure 30 Central air temp. in cabinet 10 0 Ambient temp. 30 C, no load Time (hr.) Temp. ( C) Time (hr.) Effect of ambient temp. on holding time of liquefied gas SV of backup system 70 C LCO 2 30kg Ambient temp. ( C) 35 MDF LITRES Performance data MDF-393 Temp. ( C) Pull-down characteristics under no-load condition 10 Central air temp. in cabinet 0 Ambient temp. 30 C, no load Temp. ( C) Pull-up characteristics during power failure Central air temp. in cabinet Ambient temp. 30 C, no load Time (hr.) Effect of ambient temp. on holding time of liquefied gas SV of backup system 70 C LCO 2 30kg Time (hr.) Time (hr.) Ambient temp. ( C) 36

40 Options MDF LITRES LCO 2 backup system CVK-A LN 2 backup system CVK-UBN2 Temperature chart recorder (-100ºC to +50ºC) MTR-85H Chart paper RP-85 Ink pen DF-38FP Inventory racks see page 46 Performance data MDF-192 Pull-down characteristics under no-load condition Central air temp. in cabinet 0 Ambient temp. 30 C, no load Temp. ( C) Temp. ( C) Pull-up characteristics during power failure Central air temp. in cabinet Ambient temp. 30 C, no load Time (hr.) Effect of ambient temp. on holding time of liquefied gas SV of backup system 70 C LCO 2 30kg Time (hr.) Time (hr.) Ambient temp. ( C) Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Exterior cabinet Interior cabinet Lid Insulation Compressor High side Low side Temperature Controller Temperature display Sensor Alarm Recorder Back-up system Weight Accessories MDF-794 MDF-594 MDF-393 MDF x 770 x 1070 mm 10 x 770 x 1070 mm 1860 x 800 x 945 mm 750 x 700 x 945 mm 1840 x 500 x 762 mm 1280 x 500 x 762 mm 11 x 5 x 530 mm 480 x 430 x 4 mm 701 litres 487 litres 309 litres 86 litres Baked-on acrylic finish on galvanized steel Stainless steel (SUS-304) Baked-on acrylic finish on galvanized steel Rigid polyurethane foamed-in place Hermetic type 1100W 1100W 400W 400W 1100W 1100W 400W Microprocessor controller (digital display 1ºC graduation) Digital display Platinum resistance thermo-sensor Pt 100 Selectable high temp. alarm (+10 C & +15 C from set point), Power failure alarm, Filter check lamp, Remote alarm contact Optional MTR-85H: dry cell driven recording (for 2 months) cartridge type recording pen Optional CVK-A (liquid CO 2 system) 335 kg 305 kg 248 kg 121 kg Key 1 set, Rubber caps 2pcs., defrost spatula- 1 pc. Dimensions MDF MDF-594 MDF-393 MDF-192 Unit: mm 37

41 -30ºC/-40ºC Plasma Freezer MDF-U5411 MDF-U LITRES Plasma Freezer This SANYO Plasma Freezer provides an ideal freezing environment for the preservation of vaccines, blood plasma, test samples and specimens. The user-friendly design includes a built-in door latch for each of the double outer doors, and simple calibration is possible via the control panel. This, coupled with a visual and audible alarm system, ensures that your samples are both safe and secure, but also easy to access when you need them. SAVE 38 Stable & Uniform Temperature Design Double outer doors Full-height storage containers on each shelf Cooling tubes under every shelf Direct cooling system for stable temperature control Fine-controllable refrigeration circuit with valve Large Storage Capacity 300ml FFP* bag x 280 pieces. *Fresh Frozen Plasma User Friendly Design Built-in door latch for each door Easy calibration through the control panel Visual and Audible Alarm System High & Low temperature alarm Power failure alarm with non-volatile memory back up Self-diagnostic system Safety Function Remote alarm contact Re-activating buzzer, lamp and remote alarm contact (30min. after buzzer stops) Standard door lock and independent padlock hasp door latches for extra security Remote monitoring by Data Acquisition System (Option) 1/7/30 days circular recorder (Option) Environment friendly CFC-Free refrigerant and insulation

42 Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Net Weight Effective capacity Exterior cabinet Cabinet insulation Outer door Door lock Storage container Casters Adjustable leveling feet Compressor Refrigerant Temperature control range Temperature alarm Power failure alarm Remote alarm contact Access hole Accessories MDF-U x 772 x 1802 mm 658 x 607 x 1272 mm 131 kg 482 litres Polyester finish baked on galvanized steel Foamed-in-place rigid polyurethane 2, Insulated and magnetic sealed 1 door lock, 2 lockable door latches for each door 6 pcs. Upper room, 4 pcs. Lower room 4 2 Hermetic rotary type 350W R404A (HFC refrigerant) -ºC to -40ºC (Ambient temp. 30ºC) High/low (±10ºC, adjustable), Buzzer and lamp Buzzer and lamp (Automatic rechargeable battery) Memory back up DC30V, 2A, Normal open, temperature alarm or power failure alarm Rear side (ø 30 mm) Door lock key, Defrost spatula, Storage containers * Appearance and specifications are subject to change without notice Energetic Dynamic Performance data MDF-U5411 Pull-down characteristics Ambient temp., 30 C, no load Time (h) Temperature ( C) Dimensions 10 Your SANYO Options Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85 Chart paper RP-G85 Ink pen PG-R Mounting kit MPR-S Data Acquisition System (DAQ) Interface Software MTR-480 MTR Unit: mm 39

43 -30ºC /-40ºC Freezers MDF-136 / MDF-236 / MDF-436 / MDF-U537 / Your SANYO reliable effective purposeful Biomedical Freezers SAVE SANYO s MDF Series Biomedical freezers offer the outstanding reliability and performance required in a wide variety of storage and research applications. In the medical field, they provide effective storage of lifesaving blood supplies and vaccines, as well as samples for diagnosis. In the biotechnology field, the freezers provide effective storage of enzymes for genetic research, as well as culture media, reagents and samples for testing. In the industrial field, they are ideal for ageing and temperature tests on electronic components, precision devices, and compound resins. As a storage environment, with excellent safety features, easy operability, and a host of other features, these freezers offer unsurpassed reliability and functionality. If you are looking for precision temperature controlled storage equipment, look to SANYO. 40

44 MDF- U537D / MDF-U333 / MDF-U443 Dimensions MDF-136 MDF-236 MDF-436 Unit: mm Chest type Power to cope with frequent door openings MDF ºC 138 LITRES MDF ºC 221 LITRES MDF ºC 426 LITRES Small size suitable for personal use. Digital temperature display as standard feature. Compact, personal size. Versatile mid-size model. Digital temperature display as standard feature. Easy-to-use 0-litres mid-size model Jumbo-size 400-litres class. Digital temperature display as standard feature. Large-capacity, economical size. Specifications Performance data MDF-136 / 236 / 436 Model MDF-136 MDF-236 MDF-436 Exterior dimensions 640 x 687 x 881 mm 905 x 687 x 881 mm 1265 x 807 x 905 mm (W x D x H) Interior dimensions 525 x 440 x 715 mm 790 x 440 x 715 mm 1140 x 550 x 735 mm (W x D x H) Capacity 138 litres 221 litres 426 litres Control range - C to -35 C Baskets 2 (MDF-13B) 3 (MDF-13B) 4 (MDF-43B) Access ports Cooling System Refrigerant Alarm System 17 mm diameter, right-hand side and bottom left Hermetic rotary compressor R 404A (HFC) High/low temperature alarm (SV ±5ºC to ±15ºC adjustable) Power failure Remote alarm contact Calibration Zero adjustment via control panel * Appearance and specifications are subject to change without notice Storage baskets Set of two baskets MDF-13B2 for the MDF-136/236 Set of two baskets MDF-43B2 for the MDF-436 Pull-down characteristics under no-load condition Temperature ( C) Temperature ( C) (ºC) MDF MDF-236 MDF Time (Hr) Pull-up characteristics under no-load condition (ºC) MDF MDF-236 MDF Time (Hr) MDF-136 MDF-236 MDF-436 Standard included 2 baskets, maximum 5 baskets Standard included 3 baskets, maximum 8 baskets Standard included 4 baskets, maximum 11 baskets 41

45 -30ºC /-40ºC Freezers MDF-136 / MDF-236 / MDF-436 / MDF-U537 / Upright type Maximum capacity in minimum installation space MDF-U537-30ºC 482 LITRES MDF-U537D -30ºC 452 LITRES MDF-U333-30ºC 274 LITRES Large-capacity, economical, space-saving model Top/bottom twin door design prevents cold air from escaping. Individual freezer circuits for each of the five drawers. Independent top/bottom control meets differing freezer need simultaneously. Two independent freezer cabinets in one body, with separate defrost and operation. Individual freezer circuits for each of the five drawers. Easy-to-use, compact upright model. Microprocessor digital temperature display. Convenient storage drawers. Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Capacity Cooling performance Control range Baskets Access ports Cooling System Refrigerant Alarm System Calibration Inner doors MDF-U537 MDF-U537D MDF-U333 MDF-U x 772 x 1802 mm 804 x 775 x 1800 mm 610 x 733 x 16 mm 800 x 832 x 1810 mm 658 x 607 x 1272 mm 658 x 607 x 589 mm 490 x 485 x 1290 mm 640 x 615 x 1090 mm 658 x 607 x 603 mm 482 litres 452 litres 274 litres 426 litres -30 C (AT: +35ºC) -40 C (AT: +35 C) - C to -30 C -15 C to -40 C Top: 6 medium. Bottom: 8 small 4 large, 1 small - 30mm diameter, rear Two 30mm diameter, rear 30mm diameter, 40mm diameter, left-hand side left-hand side Hermetic rotary compressor Cascade R 407 D (HFC) R 134A (HFC) R134A/R404A (HFC) High/low temperature alarm (SV ±5ºC to ±15ºC adjustable) High/low temperature alarm Power failure (adjustable) Remote alarm Power failure Remote alarm contact Door ajar Filter check Zero adjustment via control panel - - Fitted standard with 2 perspex innerdoors 42

46 MDF- U537D / MDF-U333 / MDF-U443 Performance data MDF-U537 / MDF-U537D / MDF-U333 / MDF-U443 Pull-down characteristics under no-load condition Temperature ( C) (ºC) MDF-U537/U537D Time (Hr) Temperature ( C) (ºC) MDF-U Time (Hr) Temperature ( C) MDF-U Time (Hr) Dimensions MDF-U443-40ºC 426 LITRES MDF-U537 MDF-U537D Forced air circulation & auto defrost. High freezing power increases temperature uniformity. Auto defrost for easy maintenance. MDF-U333 MDF-U443 Unit: mm Options Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85 (MDF-U333, U537, U537D,136, 236, 436) Chart paper RP-G85 Ink pen PG-R Mounting kit MPR-S7 (MDF-U537, U537D (lower room)) Mounting kit MDF-S740 (MDF-136, 236, 436) Mounting kit MDF-S740T (MDF- U333, U537D (upper room)) Temperature chart recorder (-100ºC to +50ºC) MTR-85H (MDF-U443) Chart paper RP-85 Ink pen DF-38FP Temperature chart recorder (-40ºC to +14ºC) MTR-4015LH (MDF-U333, U537, U537D, 136, 236, 436 ) Chart paper RP-40 Mounting kit MPR-S30 (MDF-U537, 537D(lower room)) Mounting kit MDF-S3040 (MDF-136, 236, 436) Inventory racks see page 46 Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 43

47 -30ºC /-40ºC Freezers Features Enhanced Operation Front-mounted display/control panel located at convenient height. Photo is MDF-U537D Memory backup. Temperature display. Front access calibration for 7-day temperature recorder. The control panel, alarm system and non-volatile memory are the same for all models in the series. Single electrical box makes servicing simpler. The chamber temperature is displayed for five seconds if BUZZER key is depressed during power failure alarm. After a power outage, operation resumes at pre-outage settings (non-volatile memory for temperature and alarm temperature settings). Control panel can be reset to zero for validation. Access ports. Four casters and two adjustable feet. Door locks Recording Features (Optional) Recorder can be fitted in a convenient position that will not interfere with installation. Choice of optional recorders*. 7-day circular recorder (MTR-G85). 7-day temperature recorder with auto recharging battery. Removable Pt100 sensor for recorder. Front access calibration for 7-day temperature recorder. Chart recorder (MTR-4015LH) is also available. Environment Friendly HFC refrigerant (non-cfc, non-hcfc refrigerant) is environment-friendly and offers superb performance. Pre-coated metal body causes less environmental damage than conventional paint coating. Safety Features Alarm & recording system. High/low temperature alarm (adjustable) Power failure. Remote alarm contact Self diagnostics ( E messages shown in red figures). Breaker switch turns power off in event of over current abnormality. Balance hinge lid stops at any angle from 35º to 90º for convenience and safety. Balance hinge allows a free choice of opening angle (Chest type) To make this chest freezer easier to use, the balance hinge keeps the door open at whatever angle you choose. That means you have both hands free for work. Lockable door latch for extra security (Upright type) By adding a commercially available lock, you can safeguard the contents of the freezer and keep hazardous items out of harm s way. (except MDF-U443) Temperature Monitoring Features Unified remote monitoring system for SANYO Biomedical products (optional). * subject to model 44

48 Inventory Racks Your SANYO practical individual How to organize your low temperature freezer Organizing the spaces in your freezer can help you to make your work more efficient. Both cost- and time savings will be the result of good sample management. But it is not only efficiency that will be influenced positively, you will also decrease the risk of damaging your samples with the right racks. This is a fact, whether you store stem cell, cord blood, bone marrow or any other type of cell or tissue samples. Whether your storage unit is an upright freezer, a chest freezer or even a liquid nitrogen freezer, an organized freezer will provide you: Time efficiency because you can locate, retrieve and replace your samples easily and quickly Cost efficiency because organized samples and cell lines might reduce the number of freezers Safety because your samples are better protected SANYO s racks are made of anodized aluminum, very light, yet sturdy and corrosion free. 45

49 Inventory Racks How to select the correct rack for your low temperature freezer organized Since this can be a challenge, we hereby give you an overview of a selection of popular freezers, in combination with a variety of racks. You will find here the most common used racks. If you are looking for another more economical/practical way to use your limited available freezer capacity, or just need a special sized rack, please contact us. Chest freezer model Vertical rack type Box type Rack/quantity Total boxes MDF-C2156VAN side openings (P) A1 15 x NIR-210C 150 side openings (P) A2 15 x NIR-307C 105 MDF-1156 side openings (P) A1 9 x NIR-9C 81 side openings (P) A2 9 x NIR-306C 54 MDF-C8V1 side openings (P) A1 6 x NIR-7C 42 side openings (P) A2 6 x NIR-305C 30 MDF-794 side openings (P) A1 36 x NIR-213C 468 side openings (P) A2 36 x NIR-309C 324 MDF-594 side openings (P) A1 24 x NIR-213C 312 side openings (P) A2 24 x NIR-309C 216 MDF-393 side openings (P) A1 21 x NIR-9C 189 side openings (P) A2 21 x NIR-306C 126 MDF-192 side openings (P) A1 6 x NIR-7C 42 side openings (P) A2 6 x NIR-305C 30 46

50 economical practical NIR-9C NIR-224U HDR-216H HCS-5584 Upright freezer model Vertical rack type Box type Rack/quantity Total boxes MDF-U4186S with trays (P) A1 8 x HCS x HCS side opening (P) A1 8 x NIR-212U + 8x NIR-215U 216 with trays (P) A2 16 x HCS side opening (P) A2 16 x NIR-309U 144 MDF-U3386S with trays (P) A1 6 x HCS / x HCS / side opening (P) A1 6 x NIR-216U + 6 x NIR-2U 216 with trays (P) A2 12 x HCS / side opening (P) A2 12 x NIR-312U 144 MDF-U33V with trays (P) A1 6 x HCS / x HCS / side opening (P) A1 6 x NIR-216U + 6 x NIR-2U 216 with trays (P) A2 12 x HCS / side opening (P) A2 12 x NIR-312U 144 MDF-U5386S with trays (P) A1 16 x HCS side opening (P) A1 16 x NIR-2U 3 with trays (P) A2 16 x HCS side opening (P) A2 16 x NIR-312U 192 MDF-U53V with trays (P) A1 8 x HCS x HCS side opening (P) A1 8 x NIR-2U + 8 x NIR-224U 352 with trays (P) A2 8 x HCS x HCS side opening (P) A2 8 x NIR-316U + 8 x NIR-312U 224 MDF-U7386S with trays (P) A1 24 x HCS side opening (P) A1 24 x NIR-2U 480 with trays (P) A2 12 x HCS x HCS side opening (P) A2 24 x NIR-312U 336 MDF-U73V with trays (P) A1 12 x HCS x HCS side opening (P) A1 12 x NIR-2U + 12 x NIR-224U 528 with trays (P) A2 12 x HCS x HCS side opening (P) A2 12 x NIR-316U + 12 x NIR-312U 336 All boxes are available: in Polypropylene (P) or carton (A) as 2 inch (1) or 3 inch (2) 47

51 Refrigerator with Freezer MPR-414F / MPR-214F accurate absolute control efficient SAVE The benefits of Enviro-center (compared to typical domestic refrigerators) Reliable temp. control not Affected by ambient temp. Digital display of chamber Temperature Precise temperature setting of chamber Variable temp. control of Refrigerator (2 C to 14 C ) Variable temp. control of Freezer (- C to -30 C) Separate operation of Refrigerator and freezer Windows for viewing Racks (SUS-304, MPR-41R) Monitoring hole/port Temperature recorder (option) Door ajar alarm High/low alarm and Overheating protection Remote alarm terminal Set temp. deviation protection Self diagnostic function Condensate evaporator Enviro center Necessary function, construction or performance for preservation of reagents and pharmaceuticals Yes Some models are Yes NO Domestic refrigerator Max/ Mid/Min -18 C Pharmaceutical Refrigerator with Freezer With the growing emphasis on proper storage of laboratory refrigerated products the market requires state-of-the-art equipment to provide unyielding parameter control. In order to achieve this goal SANYO totally redesigned the refrigerator/freezer. One unit with dual temperature zone Superior cooling performance Quiet operation Various alarm and safety devices 48

52 LED display for easy-to-read temperature and alarms Triple pane window for viewing (MPR-414F) Center pillarless design for easy access Direct cooling freezer compartment for stable temperature Your SANYO Optional Drawers (MPR-41R) -ºC Restriction enzyme and reagent preservation MPR-414F 340 LITRES + 82 LITRES Effective capacity Temperature range Refrigerator 340 litres 2ºC to 14ºC Sample and blood serum preservation -30ºC -30ºC Benefits Freezer 82 litres -ºC to -30ºC ambient temp: 30ºC Fresh frozen human blood plasma and vaccine preservation Stored product integrity assured by: Microprocessor control system that provides accurate temperature. Fan convection system in refrigerator employs ducting and plenums that provide uniform temperature throughout the cabinet. Unique refrigerator defrost system minimises temperature variations during defrost cycles by activating after each compressor cycle, thus minimizing the duration of the defrost cycle. Secondary temperature deviation safety device that prevents excessive warmup or cooling. Open door indicator light with 15 min. delayed audible alarm. Low/high temperature audible and visual alarms and remote alarm. Door locks. Energy efficient and environmentally friendly operation: Two specially designed low wattage/ energy consuming hermetic compressors. Four door design reduces air loss on entry and makes efficient use of space in front of the unit (MPR-414F). Hot gas heated mullions prevent condensation, icing and subsequent loss of gasket sealing efficiency. Very quiet operation. CFC-free foamed-in-place insulation. HCFC/CFC-free refrigerant. Efficient use of material is demonstrated by the low overall weight 126 kg (MPR-414F). LED display for easy-to-read temperature and alarms 49

53 Refrigerator with Freezer MPR-414F / MPR-214F LED display for easy-to-read temperature and alarms Double pane window for viewing Design features which enhance user operation: Two full width and three half width shelves provide 1.23m 2 (13.5ft 2 ) of refrigerator storage with 0mm (8 ) height clearance. Shelves adjustable on 100mm (4 ) centers (MPR-414F) One freezer shelf permits two levels of storage on 0.2m 2 (2.6ft 2 ) of shelf area. (MPR-414F) The top refrigerated section has a pillarless design for easy access and triple pane windows for viewing. (MPR-414F) Small radius door design. Interior incandescent light. 30mm access port for the refrigerator and freezer sections. Direct cooling freezer compartment for stable temperature Field support, operational peace of mind and future serviceability is assured by: Microprocessor self-diagnosing electronics. The use of safe HCFC/CFC-free refrigerant. Alarm and safety functions MPR-214F 176 LITRES + 39 LITRES Temperature alarm Overheating protection Memory back-up function MPR-414F Yes Yes Yes MPR-214F Yes Yes Yes Door Ajar Yes Yes Self-diagnostic function Yes Yes Key lock switch Yes Yes Performance data MPR-414F Freezer pull-down characteristics Temperature (ºC) Condition: no load, ambient temperature: 30ºC Temperature at the middle of freezer cabinet Time (Hours) Relationship between chamber temperature and ambient temperature change (compared to standard home-use refrigerators) Temperature Temperature (ºC) MPR-414F Temp. setting 5ºC Temp setting standard refrigerator 5ºC Ambient temperature Refrigerator pull-down data (ºC) Highest chamber temperature Highest chamber temperature Temperature at middle of chamber Temperature at middle of upper chamber Lowest chamber temperature Lowest chamber temperature MPR 414F Set at 5ºC:t emp.at middle of chamber, ambient temp. 35ºC Standard home-use refrigerator Set to be 5ºC at the middle of chamber Freezer chamber temperature cycle of MPR-414F compared to standard home-use refrigerators (ºC) 0 Temperature MPR-414F Temperature rise during defrosting Time (Hours) Standard refrigerator Set to low temperature. At the middle of chamber ambient temperature 35 C MPR-414F Set at -30ºC: at the middle of chamber, ambient temperature : 35ºC Time (Hours) 50

54 Specifications Model Compartment Exterior dimensions (W x D x H) Effective capacity Weight Exterior Interior Insulation Temperature range Temperature control Cooling method Compressor Refrigerant Shelves Access port Casters Alarm and safety MPR-214F MPR-414F Refrigerator Freezer Refrigerator Freezer 540 x 557 x mm 800 x 600 x mm 176 litres 39 litres 340 litres 82 litres 80 kg 126 kg Polyester resin finish baked on zinc galvanized steel Styrol resin Painted aluminium plate Stainless steel Painted aluminium plate CFC-free rigid polyurethane foamed in place 2 to 14 C - to -30 C 2 to 14 C - to -30 C Ambient temp. : 35ºC Ambient temp. : 30ºC Ambient temp. : 35ºC Ambient temp. : 30ºC Microprocessor control Fan-Forced air circulation Direct cooling Fan-Forced air circ. Direct cooling 60W 60W 160W 160W R-134A (HFC) R-134A (HFC) R-407D (HFC) 3 ( kg/shelf) 1 (10 kg/shelf) large: 2 (25 kg/shelf) 1(15kg/shelf) small: 3(15 kg/shelf) ø 30mm (left) ø 30mm (left) ø 30mm (rear) ø 30mm (rear) 4 casters with 2 adjustable leveling feet High/low temperature alarm, Door ajar alarm, Memory back up during power failure Self diagnostics, remote alarm contact (DC30V,2A), Door key lock These models are not explosion-proof/safe. DO NOT preserve chemicals that are highly volatile or corrosive. Dimensions Power cord position rt Access port MPR-214F 155 Power cord position 28 MPR-414F (Unit: Unit: mm) mm absolute control efficient accurate Options Temperature chart recorder MTR-G3504 (-10ºC to +40ºC and -60ºC to +40ºC) Chart paper RP-G3504 Ink pen PG-RB Mounting kit MPR-S7 Drawers for the bottom left compartment (MPR-414F only) MPR-41R Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 51

55 Refrigerators MPR-1410 / MPR-1410R / MPR-721 / MPR-721R reliable stable accurate Large capacity enviro-centers Your SANYO Stable and reliable refrigerated environment for exacting laboratory requirements. Environmental laboratory. Wide temperature range 2 C to 23 C (ambient temp. 0 C to 35 C). SAVE It is common knowledge that product should be stored in stable conditions below ambient temperature. Domestic refrigerators are capable of storage at +4 C, but they suffer from the following drawbacks: 1. Temperature varies every time the door is opened 2. Temperature rises during defrosting 3. Cabinet temperature is easily affected by ambient temperature, with the risk of contents freezing if ambient drops below 0 C 4. Temperature setting by dial is inaccurate (no digital temperature indication) SANYO has built solutions for all these problems into its medical refrigerators, which have been well received in hospitals, laboratories and research facilities around the world. Main Features: 1. Rapid temperature recovery after door opening. 2. Stable, uniform, and controlled cabinet temperature is unaffected by ambient temperature. 3. Cycle defrost with heater allows defrosting without increases in cabinet temperature. 4. Standard alarm and safety features prevent irregular temperature fluctuations in cabinet. Easy access front control panel (MPR-1410R) 52

56 MPR LITRES MPR-1410R LITRES Adjustable shelves and wide range set point for varying laboratory applications including chromatography and pharmaceutical storage. Drawers for convenient storage. Adjustable shelves (MPR-721/1410) The shelves can be arranged to accommodate tall apparatus such as fraction collectors. These shelves are deep enough and strong enough (50kg load for the MPR-721, 40kg for the MPR-1410) to hold most apparatus. Drawer type (MPR-721R/1410R) The R models are fitted with pull-out drawers. With a profile of 100mm and 530mm front to back, these drawers are deep enough to hold large bottles Model MPR-1410 MPR-1410R MPR-721 MPR-721R Shelves/Drawers 8 wire shelves 10 drawers 4 wire shelves 5 drawers or reagent kits. They also allow convenient, space-efficient storage and management of patient medications and other items. The MPR-721R is shipped with five drawers, while the MPR-1410R is shipped with ten drawers, five in each half of the cabinet. Temperature Stability SANYO s temperature control system with thermistor monitor and microprocessor control reliably maintains cabinet temperature at the set level and is unaffected by ambient temperature. Forced air circulation ensures that the cabinet temperature returns to the set point quickly after door openings and remains uniform throughout the cabinet. Relationship between chamber temperature and ambient temperature (comparison with standard domestic refrigerators) 14 MPR-1410: set at 5 C 100mm inside of shelves 12 MPR-1410R: set at 5 C 100mm inside of drawers 10 Standard domestic refrigerator Chamber temperature ( C) Highest Domestic highest Lowest Domestic lowest Ambient temperature ( C) 53

57 Refrigerators MPR-1410 / MPR-1410R / MPR-721 / MPR-721R MPR LITRES MPR-721R 671 LITRES Movable wire shelves for test apparatus and storage flexibility. Pull-out drawers for convenient filing of storage items. Speedy & Powerful refrigeration To cope with frequent door openings, Enviro-Centers are equipped with powerful, hermetically sealed compressors. These purpose-built compressors ensure superior pulldown characteristics and precise temperature control. Easy-to-manage layout The interior layout flexibility of Enviro- Centers makes them ideal for running experiments that require stable cool conditions, as well as storage. Standard alarm & safety features Enviro-Centers are fitted with buzzers and flashing lights to warn of high and low temperature problems. In the event of an irregular rise in cabinet temperature, the heater automatically shuts off and forced air circulation brings the temperature down. Door locks are fitted to safeguard valuable contents. Large Capacity With a modular width of 770mm the MPR-721 offers a capacity of 684 litres (MPR-721R: 671 litres), while the 1440mm wide MPR-1410 offers a capacity of 1370 litres (MPR-1410R: 1365 litres). The interior is spacious enough to accommodate column chromatography apparatus or large volumes of reagents, test samples and biologicals. Wide temperature range With a temperature range of 2 C to 23 C, Enviro-Centers are ideally suited for tests that require a stable, cool temperature. Large fans The 1mm diameter fan ensures an even temperature throughout the cabinet (MPR-1410/R models have a double flow system with two fans). Heat spots from powered test apparatus are minimized and pulldown characteristics after door openings are outstanding. HFC Refrigerant & CFC free insulation SANYO biomedical equipment is designed for low environmental impact. The MPR-721 and 1410 series use HFC refrigerant, and the foamed-inplace insulation is also CFC free. Cycle defrost In the 5 C range, frost build-up on the evaporator is inevitable. This can affect the performance of the heat exchanger. SANYO has solved this 54

58 Dimensions Performance data MPR-1410 / MPR-1410R MPR-1410 Pull-down characteristics (no-load) 40 MPR-1410 MPR-721 Temp. ( C) Temp. in chamber ( C) Air temp. at centre of chamber Ambient temp. 35 C Time (min.) MPR-1410 Pull-up characteristics (no-load) Air temp. at centre of chamber Ambient temp. 35 C 5 Initial conditions: chamber stable at 2 C Time (min.) MPR-1410 Test of permissible inside thermal load Inside thermal load (W) ºC 10ºC 5ºC 2ºC MPR-1410R MPR-721R Unit: mm Ambient temperature ( C) problem with a cycle defrost and evaporator temperature sensor system. This system runs automatically, so there is no need to turn off the power for defrosting. Temperature rise during defrost is minimal. The evaporation heater also doubles as protection against drops in cabinet temperature caused by a low ambient temperature. Other features (MPR-721/721R) New concept features have been added to the MPR-721 and 721R. The filterless condenser cuts down on cleaning maintenance. All glass doors now include a protective film to prevent shattering in the event of accidental collisions. User friendly design and double function door Easy to read and operate control panel featuring a full array of alarm and safety functions. Access ports are standard to allow access for power cords. Aesthetically attractive exterior colour blends well in most lab colour schemes. The catch-free rounded corners are safe and attractive. Doors open smoothly and close automatically. Some laboratory refrigerators have solid doors for temperature stability, while others have glass doors for easy viewing. SANYO Enviro-Centers give you the best of both versions. The broad, solid frames with effective gaskets ensure excellent temperature stability, and the double-pane glass windows offer an excellent view of the interior without compromising temperature stability. Performance data MPR-721 / MPR-721R Temperature ( C) MPR-721 Permissible inside thermal load Inside thermal load (W) Air temp: at center of chamber Ambient temp.: 30 Power source: Single phase 100V 50Hz Time (hour) Temperature pull-up characteristics Temperature pull-down characteristics Ambient temperature ( C) 23 C 10 C 5 C 2 C 55

59 Refrigerators MPR-1410 / MPR-1410R / MPR-721 / MPR-721R Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity MPR x 830 x 1950 mm 13 x 710 x 1500 mm 1370 litres MPR-1410R 1365 litres MPR x 830 x 1955 mm 650 x 710 x 1500 mm 684 litres MPR-721R 671 litres Exterior Interior Doors Insulation 2 x double pane glass doors, self closing Acrylic finish baked on zinc galvanised steel Acrylic finish baked on zinc galvanised steel 1 x double pane glass door, self closing CFC-free rigid foamed-in-place polyurethane Shelves/Drawers 8x polyethylene-coated 10x coated steel drawers. 4x polyethylene-coated 5x coated steel drawers. wire shelves. Handles with card holder. wire shelves. Handles with card holder. Max. load: 40kg/shelf Max. load: 40kg/drawer Max. load: 50kg/shelf Max. load: 40kg/drawer 3x30mm Ø (2 in sides, 1 in cabinet top) 2 x cylinder type 1 x cylinder type 4 Access ports Locks Castors Cooling method Compressor Evaporator Condenser Refrigerant Defrost method Defrost heater Power source Temperature control Temperature display Safety features High temp. alarm Low temp. alarm Door ajar alarm Interior lamp Net weight Voltage Hz Phase Forced air with double fan Forced air with single fan 300W hermetic rotary 0W hermetic Reciprocating Fin tube type Fin tube type Wire tube type R-134A Forced type (cycle defrost system), fully automatic. Hot pipe for automatic evaporation of drain water 257W 153W 230/240V 230/240V 50Hz 50Hz 1Ø 1Ø Microprocessor ON/OFF type. Thermistor sensor temp. control range: 2 C to 14 C (ambient temperature -5 C to 0 C no-load). 2 C to 23 C (ambient temperature 0 C to 35 C no-load) (1 C step) Digital type (1 C step) High temp. protection circuit, low temp. protection circuit, temperature lock, self diagnostics, memory backup (non volatile memory) 2 C to 14 C (selectable) above set point, flashing LED & buzzer 2 C to 14 C (selectable) below set point, flashing LED & buzzer Flashing lamp, buzzer after 2-minute delay 40Wx1, fluorescent lamp Wx1, fluorescent lamp 231 kg 267 kg 174 kg 193 kg *Appearance and specifications are subject to change without notice Alarm and safety features Features Trigger Type of alarm/response High temperature alarm 2 C to 14 C (selectable) above set point Flashing LED & buzzer Low temperature alarm 2 C to 14 C (selectable) below set point Flashing LED & buzzer Over heating protection Interior temperature rises to 40 C Fan motor & heater OFF Options Temperature lock Lock ON Set temperature can not be altered Temperature chart recorder (-6 C to + C) MTR-0621LH Chart paper RP-06 Mounting kit MPR-S30 Circular Temperature chart recorder (-10 C to +40 C) MTR-G04 Chart paper RP-G04 Ink pen PG-R Mounting kit MPR-S7 Exterior Power failure alarm MPR-48B (MPR-721 only) Memory backup Door ajar Self diagnostics Remote terminal alarm Temperature recorder Power failure Door not closed Sensor open or short Operation can be checked from office or control room away from the lab Optional Memory of settings Door ajar lamp ON Error code shown Data Acquisition System (DAQ) Interface MTR-480 Software MTR-00 Mounting bracket MPR-48B 56

60 Every individual is important in research. Your personal input can make a difference. Which is why your research results should be personal too. Your efforts should be focused on your research not in safeguarding the results. You and SANYO a perfect match. NEW mid 09 innovative SANYO VISION Knowing the field and understanding what is needed is a key issue for SANYO. For example, safeguarding your research - which may be the result of years of hard work. Passwords and passes can be exchanged, but with SANYO biometric systems your results are personal again. SANYO Bio Secure is the result of innovative thinking aimed at keeping things simple and secure. A user-friendly fingerprint recognition technique makes it possible for you to focus your effort into your research and not in safeguarding the results. So you can rely on SANYO Bio Secure to keep guard while you focus on your work. SANYO Bio Secure 57

61 Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R Your SANYO Equipped with sliding racks. 2 C to 14 C (Ambient temperature from -5 C to +35 C) MPR-1014R LITRES Stable and reliable environment control the key to high-precision performance for exacting storage or research requirements Spacious capacity meets versatile requirements of pharmaceutical refrigeration, from small-variety packages to large-variety packages. SAVE Several factors are important to assure the quality of pharmaceuticals, samples and reagents. These are storage temperature, expiry date, exposure to ultraviolet light and humidity. Of these the most important is storage temperature. If the temperature is too high, chemical changes can occur which affect the quality of the materials. If the temperature is too low, there is a risk of structural changes brought about by freezing. Narrow and uniform temperature control without regard to ambient conditions is very important. Don t compromise your results! 58

62 stable precise efficient Uniform storage unaffected by ambient temperature Microprocessor controlled An electronic sensor accurately monitors chamber temperature and feeds the information to the microprocessor for precise control at preset temperature. Fans ensure gentle air circulation to provide uniform top to bottom temperature control after frequent door openings. SANYO s easily calibrated, reliable and stable controls make validation easier. Remarkable cooling efficiency A highly efficient hermetic compressor, specially designed and developed by SANYO, is utilized to provide powerful and rapid cooling to maintain proper temperature level. Ergonomic design The ergonomic design of the MPR series refrigerators provides a clear view of stored items through the large framed windows. The slim profile allows for easy-reach retrieval of your products. Users can choose from two types to suit their needs; one with all wire shelves or one with sliding racks on one side. Double-sensor temperature management The double-sensor control system with alarm-exclusive sensor added to the temperature control sensor always monitors the precise chamber temperature. Safety is a SANYO standard Even the best designed refrigerator must be prepared for the unexpected. Cabinet construction View Window design with protective film to prevent shattered glass from scattering onto the floor. Also features key locked doors. Control safety devices Audible and flashing LED visual alarms alert you to the unlikely event of either a high or low temperature condition. An overshooting prevention circuit automatically switches off the fan motor or heater, if the inside temperature rises abnormally. Comprehensive alarms In addition to Low/High temperature alarms and door ajar alarm, power failure alarm can be installed as an option. Remote alarm terminal is also provided as standard. Plenums SANYO s plenum design features uniform cold air flow distribution throughout the chamber to ensure temperature uniformity - essential for validated storage requirements. Worry-free cycle defrosting system With SANYO s cycle defrost system, defrosting is performed automatically during compressor off cycles, and by sensing frost levels. This way defrosting is performed only when required, further protecting the contents against unnecessary temperature rise. The defrosting heater also acts as an emergency heat source to prevent samples from freezing. HCFC refrigerant & HCFC-free insulation SANYO biomedical equipment is designed for low environmental impact. The MPR-514 and 1014 series use HCFC refrigerant and the foamedin-place insulation is HCFC free. 59

63 Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R MPR LITRES MPR-514R 486 LITRES Specifications 2 C to 14 C (Ambient temperature from -5 C to +35 C) Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective Capacity Exterior cabinet Interior cabinet Outer door Cabinet insulation Outer door lock Shelves and sliding racks Cooling method Evaporator Condenser Compressor Refrigerant Fan motor for cooling for condensing Defrosting Defrost heater Weight MPR-1014, MPR-1014R MPR-514, MPR-514R 1800 x 600 x 1790 mm 900 x 600 x 1790 mm 1700 x 465 x 1300 mm 800 x 465 x 1300 mm 1033 litres MPR litres MPR litres MPR-1014R 486 litres MPR-514R Baked-on acrylic finish galvanized steel Stainless steel 2 sliding doors, Double layer glass window with heat reflecting film HCFC-free rigid polyurethane foamed-in-place 1 10 polyester coated wire shelves 5 polyester coated wire shelves Load: 50 kg per shelf (MPR-1014) Load: 50 kg per shelf (MPR-514) 5 polyester coated wire shelves 5 polyester coated wire shelves Load: 50 kg per shelf Load: kg per shelf 10 polyester coated sliding racks 5 polyester coated sliding racks Load: kg per rack (MPR-1014R) Load: kg per rack (MPR-514R) Forced cool air circulation Fin and tube Fin and tube Wire tube, tube on sheet Hermetic type, output: 250W Hermetic type, output: 0W R404A R-134A For cooling: output 3W x 2 For cooling: output 3W x 1 For condensing: output 4W Forced type, fully automatic 141W 73.8W x 2 243kg MPR kg MPR kg MPR-1014R 147kg MPR-514R *appearance and specifications are subject to change without notice. 60

64 Performance data MPR-1014 / MPR-1014R / MPR-514 / MPR-514R Uniform Storage Temperature-ambient Temperature Uniform Storage Temperature-Cycle Defrost SANYO MPR Inside Temperature ( C) SANYO MPR Ambient Temperature (ºC) 25 Upper limit of cycle Center of Cabinet Lower limit of cycle Inside Temperature (ºC) Ambient Temperature ( C) Time (Hr) Your SANYO Inside Temperature ( C) Conventional Refrigerator Upper limit of cycle Center of Cabinet Lower limit of cycle Ambient Temperature ( C) Conventional Refrigerator Ambient Temperature (ºC) 25 Temp. rise during defrost cycle Time (Hr) secure ambitious precise Options Temperature chart recorder (-6 C to + C) MTR-0621LH Chart paper RP-06 Mounting kit MPR-S30 Circular Temperature chart recorder (-10 C to +40 C) MTR-G04 Chart paper RP-G04 Ink pen PG-R Mounting kit MPR-S7 External mounting Power Failure Alarm MPR-48B Data Acquisition System (DAQ) Interface Software Mounting bracket MTR-480 MTR-00 MPR-48B Dimensions (inside) 158 (duct) (duct) (inside) 158 (duct) Front elevation End section Front elevation End section Unit: mm MPR-514/MPR-514R MPR-1014/MPR-1014R 61

65 Refrigerators MPR-161D / MPR-311D MPR-161D 158 LITRES MPR-311D 340 LITRES Safe, worry-free cold storage of valuable medical supplies Medical refrigerators for reliable storage of pharmaceutical and medical supplies. For a versatile range of storage applications compact and largecapacity medical refrigerators. SAVE SANYO pharmaceutical refrigerators safe, worryfree cold storage of valuable medical supplies. To ensure quality, safety and effectiveness of vital medical supplies, SANYO medical refrigerators feature precisely regulated cooling systems that maintain a delicate temperature balance under a wide range of conditions. For many years, SANYO has provided equipment for medical supply storage and temperature control to hospitals and pharmacies throughout the world. Now, utilizing this accumulated experience plus valuable feedback from the medical community, SANYO has developed the Medi-Cool line of medical refrigerators, each of which is equipped with advanced cooling and electronic technology to provide the ideal temperature for the perfect preservation of a wide range of medical supplies. Remarkable Cooling Efficiency Taking into consideration that pharmaceutical refrigerators must be opened frequently, a highly efficient hermetic compressor, specially designed and developed by SANYO, is utilized in each model of the Medi-Cool series. The hermetic compressor provides powerful, immediate cooling which is effective in maintaining the inside temperature at a constant level. 62

66 Options Temperature chart recorder (-6 C to + C) Chart paper MTR-0621LH RP-06 Performance data MPR-161D / MPR-311D Your SANYO Relationship between the inside temperature and ambient temperature secure dynamic efficient Inside temp. (ºC) Inside temp. (ºC) Ambient temp. (ºC) Sanyo MPR 10 Temperature at center 8 of cabinet Conventional home refrigerator Temperature at center of cabinet Effective Temperature Control 1. Electronic Temperature Control System A thermistor sensor monitors temperature inside the chamber and microprocessor and electronic temperature control ensure that the set temperature is maintained. Even if the door is opened and closed frequently, the circulation fan ensures rapid temperature adjustment to provide a highly reliable, stable preservation environment that is not affected by ambient temperature. The MPR-161D and 311D have a digital temperature display for easy confirmation. temperature apparent inside the cabinet. 3. Cyclical Defrosting System During normal operation, the cyclical defrosting system permits defrosting to take place without increasing the temperature inside the cabinet. Equipped with Digital Temperature Display Easy-to-read digital temperature display provides at-a-glance confirmation of the current operating temperature. To simplify temperature control, temperature readings are displayed in graduations of 1ºC for temperatures ranging from 0ºC to 15ºC Ambient temp. (ºC) Comparison with conventional refrigerators Conventional refrigerators (ºC) Ambient temp. (ºC) Temp. rise during defrosting cycle Time (Hr) Sanyo MPR (ºC) Ambient temp. (ºC) 2. Fan-Forced Air Circulation The temperature stays even throughout the inside of the refrigerator with the fan-forced air circulation system. No matter how the load is distributed, every corner of the unit is immediately cooled with no noticeable variation in Easy-to-Use Doors 1. Double-Paned Glass with Heat- Reflective Film The refrigerator doors, constructed of double-paned glass with heat-reflective film, allow easy loading and unloading of medical supplies while preventing Inside temp Time (Hr) 63

67 Refrigerators MPR-161D / MPR-311D ultraviolet rays, which may damage the stored items, from entering the unit. SANYO s unique heat-reflective film blocks the passage of radiant heat rays through the glass panels and keeps the inside temperature from being adversely affected by excessive amounts of heat. 2. Door Open Alarm When the door is opened, the Door Open indicator lamp lights automatically. After approx. 30 seconds a buzzer alarm will sound if the door has not been closed. When you want to keep the door open for more than 30 seconds, you can deactivate the alarm via the buzzer switch provided. Abnormal Temperature Alarm and Safety Devices 1. Abnormal Temperature Alarm If the inside temperature suddenly descends to below 0ºC or rises to above 15ºC, the buzzer sounds an alarm. Simultaneously, the digital temperature display flashes. or above ºC (approx.), the low and high-temperature safety devices prevent the contents of the refrigerator from freezing or the temperature from rising abnormally while visible and audible alarms are activated. Rigid polyurethane foam insulation acts to keep cold air inside the unit and effectively protects against the intrusion of warm air. Chemical-resistant interior surface of the cabinet ensures reliable service for many years of use. Less installation area is required with the use of 2 easy-open sliding doors. reliable 2. Abnormal Temperature Safety Device If the internal temperature reaches below 2ºC accurate commited Specifications Model Exterior dimensions Interior dimensions Effective capacity Cabinet Interior Insulation Doors Shelves Monitoring hole Lighting Castors Power source Voltage Hz Phase Amps. Compressor Refrigerant Evaporator Condensor Defrosting Defrosting heaters Temperature control Temperature display High-temperature alarm system Low-temperature alarm system Door ajar alarm Weight MPR-161D MPR-311D 800 x 450 x 1090 mm 800 x 450 x 1800 mm 7 x 300 x 725 mm 7 x 350 x 1435 mm 158 litres 340 litres Baked-on acrylic finish on galvanized zinc-plated Stainless steel Polyurethane foam Sliding glass doors, double-paned glass with heat-reflective film Rigid wire with polyethylene coating finish 30mm diameter on back wall W fluorescent lamp (1) 2 230/240V 50Hz 1 0,9A 1,3A Hermetic type, 90W Hermetic type, 160W R-407D Fin & tube, forced-air circulation Wire & tube Cyclical defrosting & evaporator temp. detection system. 101W 114W Electronic temp. control (range: 2ºC-14ºC) Digital (display range: 0ºC-15ºC) Flashing digital indicator (above 15ºC), Buzzer (above 15ºC) High temp. indicator lamp (above approx. ºC) Flashing digital indicator (below 0ºC), Buzzer (below 0ºC) Defrost indicator lamp (below approx. -2ºC) Buzzer/door ajar alarm 59 kg 90 kg * Specifications subject to change without notice 64

68 Dimensions MPR-161D MPR-311D Unit: mm 0,01 Percentage environmently conscious vision Global water resources are said to amount to 1.4 billion km 3 : most of this is seawater, with fresh water accounting for only 2.5% of the total. The majority of freshwater is frozen in glaciers or held underground. Freshwater from rivers and lakes - which we can use directly - is indeed a valuable resource. But it accounts for only 0.01% of the Earth's water resources. In Indonesia, where most households obtain their water from wells, SANYO has been able to help with water supply by providing pump technology. In fact, the local people refer to a pump as a Sanyo. These pumps offer local inhabitants a healthier and more comfortable life through clean water. You and SANYO: a perfect match SANYO is focusing on water purification and ozone disinfection systems to encourage the reuse of limited water resources. To preserve clean water for future generations, we have developed products equipped with water recycling functions as standard. By developing environmentally and economically beneficial innovative products, we are proposing a lifestyle that values water without compromising comfortable living. 65

69 Refrigerators MBR-304GR / MBR-704GR / MBR-1404GR / MBR-107D / Your SANYO dedicated MBR-304GR 302 LITRES 1 Blood bags 450 ml secure accurate Cooling performance: 4ºC ±1ºC (Ambient temp. 35ºC) Blood Bank Refrigerators SANYO MBR-series provide two styles of storage systems, D-type (coated steel wire shelf) and GR-type (stainless steel roll-out drawer with card holder). Designed to conform to AABB criteria, with assured stable and reliable temperature control utilizing SANYO original technology: A special highly efficient compressor designed and developed by SANYO, to provide rapid cooling and quiet performance for each model. Stable Temperature Control Temperature is controlled by two sensors located in the liquid-loaded monitor bottles, which are in the shape of a blood bag. Two thermistor sensors for constantly monitoring the temperature in both the upper and lower part of the chamber. Microprocessor control ensures the most accurate temperature control available. Multi air-flow plenum system ensures excellent temperature uniformity in larger capacity models. (MBR-704GR, MBR-1404GR). Temperature-maintained defrost, designed with thermal sensors and heaters on the evaporator, all under precise microprocessor control. Temperature Variations Prevented SANYO MBR series are designed to minimize cold air loss even with frequent door openings. Seperated transparant inner doors minimize the chamber air leakage during door openings. Foamed-in-place insulation in the walls and magnetic sealed outer doors with double-pane glass window prevent chamber air leakage and promotes complete door closings. Large air circulation fan enables rapid temperature recovery after door openings (double fan for MBR-1404GR). 66

70 MBR-506D MBR-704GR 617 LITRES 360 Blood bags 450 ml MBR-1404GR 1287 LITRES 7 Blood bags 450 ml Cooling performance: 4ºC ±1ºC (Ambient temp. 35ºC) Cooling performance: 4ºC ±1,5ºC (Ambient temp. 35ºC) User Friendly Design Selectable storage system (D-type and GR-type) to suit user needs. Fluorescent interior lamp with ON/OFF switch and a large view window in the outer door provide a clear view of stored items. Digital display is easy to see, and is calibratable through the control panel. easy-to-use display at the front Alarm and safety functions To ensure the safety of the precious blood supply, SANYO MBR series provide the following safety functions. Audible and flashing LED visual alarms with remote alarm contacts, in the event of power failure, high or low temperature condition, or due to thermal sensor abnormality. Door alarm and key lock are standard features. Re-activating buzzer, lamp and remote alarm-contact. (30min. after buzzer stops). Built-in temperature recorder. Environment Friendly SANYO refrigerators feature commercially available CFC-free, HFC refrigerants and CFC-free insulation. Temperature Monitoring Features Unified remote monitoring system for SANYO Biomedical products (optional). note: descriptions in this catalogue are based on the models MPR-304GR, 704GR, 1404GR 67

71 Refrigerators MBR-304GR / MBR-704GR / MBR-1404GR / MBR-107D / MBR-107D 79 LITRES 32 Blood bags 450 ml MBR-506D 425 LITRES 1 Blood bags 450 ml Cooling performance: 4ºC ±1ºC (Ambient temp. 35ºC) Cooling performance: 4ºC ±1ºC (Ambient temp. 35ºC) Performance data MBR-304GR / MBR-704GR / MBR-1404GR Pull-down characteristics Pull-down characteristics Pull-down characteristics Pull-up characteristics during power failure Pull-up characteristics during power failure Pull-up characteristics during power failure * A continuously operating compressor was used to obtain data for the three pull-down graphs. 68

72 MBR-506D Your SANYO dedicated Options Temperature chart recorder is standard built-in on the MBR models Chart paper RP-G04 (for MBR-304GR, 704GR, 1404GR) Ink pen PG-R (for MBR-304GR, 704GR, 1404GR) Chart paper RP-06 (for MBR- 107D, 506D) Chart paper RP-G04 (for MBR-304GR, 704GR, 1404GR) Data Acquisition System (DAQ) (for MBR- 304GR, 704GR, 1404GR) Interface MTR-480 Software MTR-00 reliable accurate Storage basket MBR-15B (for MBR-107D) 7 bags of 2 ml, max. 8 baskets MBR-16B (for MBR-107D) 4 bags of 450 ml, max. 8 baskets MBR-55B (for MBR-506D) 10 bags of 2 ml, max. baskets MBR-56B (for MBR-506D) 6 bags of 450 ml, max. baskets Dimensions MBR-304GR MBR-704GR MBR-1404GR MBR-107D MBR-506D Unit: mm 69

73 Refrigerators MBR-304GR / MBR-704GR / MBR-1404GR / MBR-107D / Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Net weight Effective capacity Storage capacity Exterior cabinet Interior cabinet Cabinet insulation Outer door Door lock Inner door (Acrylic) Drawers Casters Compressor Refrigerant Cooling performance Air circulation Defrost Temperature control Temperature alarm Power failure alarm Door alarm Remote alarm contact Temperature monitor bottle Lighting Access hole Accessories MBR-304GR MBR-704GR MBR-1404GR 600 x 680 x 1835 mm 770 x 830 x 1955 mm 1440 x 830 x 1950 mm 5 x 490 x 1150 mm 650 x 697 x 1500 mm 13 x 697 x 1500 mm 140 kg 210 kg 290 kg 302 litres 617 litres 1287 litres 1 bags (450 ml) 360 bags (450 ml) 7 bags (450ml) Baked-on acrylic finish galvanized steel Baked-on acrylic finish galvanized steel CFC-free rigid polyurethane, foamed-in place Insulated steel frame with double layer glass windows stainless steel roll-out drawers 6 stainless steel roll-out drawers 12 stainless steel roll-out drawers W Hermetically sealed 2W hermetically sealed 300W hermetically sealed R 134a 4 C ± 1 C (ambient temperature 35 C) 4 C ± 1.5 C (ambient temperature 35 C) Forced air circulation Fully automatic Microprocessor control High (6 C), Low (2 C), Audible and visual alarm Audible and visual alarm (24 hours), automatic rechargable battery (Ni-MH) Audible and visual alarm DC30V,2A. Normal open, Temperature alarm or power failure alarm 250ml x 2 with thermistor sensor 15W Fluorescent lamp W fluorescent lamp 40W fluorescent lamp 1 2 1/7/30 days circular recorder Door lock key Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Net weight Effective capacity Storage capacity Exterior cabinet Interior cabinet Cabinet insulation Outer door Door lock Inner door (Acrylic) Shelves Casters Compressor Refrigerant Cooling performance Air circulation Defrost Temperature control Temperature alarm Power failure alarm Door alarm Remote alarm contact Lighting Access hole Accessories MBR-107D MBR-506D 400 x 495 x 1515 mm 800 x 832 x 1810 mm 3 x 350 x 710 mm 540 x 550 x 1240 mm 70 kg 185 kg 79 litres 425 litres 32 bags (450ml) 1 bags (450ml) Baked-on acrylic finish galvanized steel Stainless steel CFC-free rigid polyurethane, foamed-in-place Triple layer glass windows zinc plated steel wire and 1 stainless steel 4 coated hard steel wire and 1 stainless steel W Hermetically sealed 160W Hermetically sealed R-134a R-412A (TP5R) 4 C ±1 C (ambient temperature 35 C) Forced air circulation Fully automatic Microprocessor High (6 C), low (2 C), Audible and visual alarm Audible and visual alarm (9 hours), Automatic rechargeable battery Visual alarm DC30V,1a, Normal open DC24V,1A, Normal open Temperature alarm or power failure alarm 6W Fluorecent lamp 15W Fluorecent lamp 1 30 days recorder, Door lock key 1 set *Appearance and specifications are subject to change without notice. 70

74 MBR-506D Sometimes you need support to reach for the top. Your vision is what gets things done. Our vision is to create an environment in which you can reach your full potential. We support you with a service team you can rely on. Which leaves you with no distractions: just pure focus. You and SANYO a perfect match. SANYO VISION involved reliable At SANYO we appreciate how much your samples and products are worth to you. Your chosen equipment has been manufactured using world leading technology and specialist engineering, so it is important that we continue to provide the best support and care possible to maximize the potential and lifespan of your equipment. We have a dedicated team of SANYO Service Specialists who are trained to carry out repairs and service to our exacting standards, ensuring the support you need during the life of your equipment. SANYO Support and Service 71

75 General Purpose Laboratory Refrigerators reliable Your SANYO practical SRR-23GD +4 C 600 LITRES General Purpose Laboratory Refrigerators Everyday, laboratories around the world rely on SANYO for their refrigerated storage requirements, reassured by an industry-leading reputation for performance and durability. SANYO s General Purpose Laboratory Refrigerators are ideal for routine storage applications in clinical, life science, pharmaceutical and industrial laboratories. Microprocessor temperature control with digital display and alarm function Fan circulation for enhanced temperature uniformity Flexible storage with capacities from litres Durable heavy duty refrigeration systems, ideal for frequent door openings Stainless steel interior and exterior Choice of double-glazed glass or solid swing doors Auto-defrost 72

76 Solid door models Solid stainless steel doors for enhanced security or for light sensitive samples Door locks (solid door models only) SRR-23FD +4 C 600 LITRES SRR-49FD +4 C LITRES Glass door models Energy efficient doubleglazed glass doors for quick location of samples SRR-49GD +4 C LITRES SRR-72GD +4 C LITRES 73

77 General Purpose Laboratory Refrigerators Environmentally friendly (HFC), high efficiency refrigeration system with auto-defrost Microprocessor control for stable temperatures Temperature alarm LED digital display Automatic internal lamp Durable stainless steel interior and exterior Fan circulation for greater temperature uniformity High density, foamedin-place insulation protects samples and reduces energy use Adjustable epoxy coated shelving offers flexible storage Lockable, heavy-duty castors for straightforward installation 74

78 Specifications Model SRR-23GD-MEDE SRR-49GD-MEDE SRR-72GD-MEDE SRR-23FD-MEDE SRR-49FD-MEDE Type Refrigerator Refrigerator glass doors solid doors Weights & Dimensions Capacity, litres (1.100 & 600) Internal dimensions (W x D x H) 6 x 700 x mm x 700 x mm Left compartment: 6 x 700 x mm x 700 x mm x 700 x mm Right compartment: 6 x 700 x mm External dimensions (W x D x H) 739 x 805 x mm x 805 x mm x 805 x mm 739 x 805 x mm 1260 x 805 x mm Nett Weight, kg Construction Door type Double-glazed glass door Stainless steel door Number of doors Door lock - Yes Exterior Stainless steel (grade 430) Interior Stainless steel (grade 304) Insulation High density polyurethane, foamed in place Insulation thickness, mm 60 mm Castors (qty) 4 pcs. Shelves Adjustable, epoxy coated steel wire Qty of shelves 4 8 (4 per section) 12 (4 per section) 4 8 (4 per section) Interior illumination Automatic interior lighting Control Temperature setting range -3 C ~ +10 C (Ambient temperature +32 C) Standard setting +4 C Control Microprocessor Display LED (top mounted) Temperature alarm Fixed +/- 5 C around set-point. Refrigeration Compressor(s) 185W 245W 185W + 245W 185W 245W Refrigerant R-134a Defrost Automatic evaporator defrost + manual forced defrost Cooling method Forced air circulation (fan) Power Voltage 2-240V Frequency 50Hz Phase 1 Current 4A 4.5A 6.5A 4A 4A Option Additional shelves ton less CO 2 environmently conscious To further expand its rechargeable battery business, SANYO Electric started the development of HEV battery systems in After achieving the industry's highest-level performance in 1999, we have been exclusively supplying battery systems for Ford Motor's "Escape Hybrid" - the world's first hybrid electric SUV (sports utility vehicle) since 04. In the United States, an average gasolinepowered vehicle gets 8.5 km to a litres, runs an average of 18,870 km a year, and emits 2.32 kg of CO 2 per litres. Ford Motor has sold 76,041 Escape Hybrid vehicles in the United States so far (September 04 - May 08), from which the total reduction in CO 2 emissions can be calculated to be 246,264 tons. Vision 75

79 CBS Isothermal -190ºC Dry Storage Freezers Your SANYO dedicated The world of -190ºC CBS Isothermal Freezers feature a patented liquid nitrogen jacket to provide uniform storage temperatures in the -190 C range, free from liquid nitrogen contact. This innovative design eliminates the risk of cross-contamination through liquid nitrogen and the need for additional packaging to protect valuable cells and tissue C With a minimal temperature gradient, the full internal volume of each freezer is available for storing samples at liquid nitrogen temperatures making the most efficient use of available capacity. CBS Isothermal Freezers also provide added user safety by eliminating contact or splashing of liquid nitrogen. All models are certifide to the Medical Device Directive 93/42/EEC: 1993 Class IIA and feature the Series 2300 Auto-fill and Monitor System providing sample security and ease of operation. A wide selection of inventory systems for vials and bags are also available. Installation, commissioning and calibration service are available C New is the Straw Storage Inventory System. Designed for the CBS V-1500AB Isothermal Freezer, this patent-pending Inventory System provides an efficient solution for storing and working with straws, free from liquid nitrogen contact. Working with a 3-level rotating carousel, the system can hold up to straws in 68 canisters. 76

80 innovative Outstanding temperature uniformity in the -190 C range. No loss of storage space. No cross-contamination through liquid nitrogen. User safety with no liquid nitrogen in the sample storage area. Automatic operation and filling. Certified to Medical Device Directive 93/42/EEC: 1993 Class IIA. Choice of 4 models offering capacities between 9,100 and 45,000 2ml vials. reliable The Isothermal Concept The sample storage area is cooled by a liquid nitrogen jacket surrounding the stainless steel interior, and by nitrogen vapour entering the freezer from the jacket via directional vents. This patented technology provides exceptional temperature uniformity in the -190 C range, allowing the full freezer capacity to be used with confidence. The circulation of vapour within the freezer also results in less cold air loss during lid opening and improved visibility. This allows full-width lids to be used providing quick, unrestricted access to sample racks. Vacuum Insulated Jacketing Temperature Controlled Storage Area Liquid Nitrogen Envelope Features No Liquid Nitrogen Contact With no liquid nitrogen in the storage area, samples can be stored safely in the -190 C range without the risk of cross-contamination through liquid nitrogen. The Isothermal design also provides added user safety with no splashing or contact of liquid nitrogen when removing racks and samples from the freezer. Automatic Operation CBS Isothermal Freezers feature the Series 2300 Auto-fill and Monitor System, which controls the automatic filling of the liquid nitrogen jacket and provides the user with an easy to read overview of the freezer temperature and status. Sample Security A comprehensive alarm system with remote alarm contact constantly monitors all aspects of the freezer s operation. Samples are also protected by lid and control panel locks. The freezer can be monitored by a central BMS or monitoring system. Sample Storage A wide selection of inventory systems for vials and bags are available to complete the system and optimize sample storage. 77

81 CBS Isothermal -190ºC Dry Storage Freezers CBS Straw Storage Inventory System Designed for the CBS V-1500AB Isothermal Freezer, this patent-pending Inventory System provides an efficient solution for storing and working with straws, free from liquid nitrogen contact. Ideal for IVF and other straw storage applications* Isothermal dry storage with uniform temperatures throughout the freezer from -195 C to -190 C. 3-level rotating carousel provides convenient inventory control and maximises storage space. The system can hold up to 24,480* straws in 68 canisters. The middle and lower levels are ideal for medium and long-term storage respectively, whilst the upper level can be used for storage and as a workspace for viewing and manipulating samples safely at -190 C. Easy retrieval of samples using the patent-pending retrieval tool C -195 C * Maximum capacity is subject to straw diameter. Straws and goblets are not supplied. How the System works. Rotating carousels provide access to lower storage levels and maximise storage space. The upper level provides a convenient workspace where canisters can be parked (shown in green) and samples inspected at -190 C. Use the retrieval tool to place and retrieve canisters quickly and easily. Specifications Isothermal -190 C Dry Storage Freezers Model V-1500AB V-3000AB V-5000AB V-5000ABEH Liquid nitrogen capacity (litres) Static evaporation rate (litres/day) Static holding time (days) External dimensions (W x D x H) 660 x 939 x x 1219 x x 1371 x x 1371 x 1473 Usable interior height (mm) 736 mm 736 mm 736 mm 864 mm Usable interior diameter (mm) 534 mm 787 mm 1016 mm 1016 mm Weight empty 148 kg 272 kg 425 kg 453 kg Weight full 174 kg 327 kg 500 kg 566 kg Max. vial capacity (2ml)* Max. blood bag capacity (50ml)* * Capacity is subject to rack type 78

82 CBS Cryosystems Liquid Nitrogen Storage CBS manual-fill Cryosystems provide versatile, low cost sample storage at cryogenic temperatures with maximum capacity and low liquid Nitrogen consumption. Features XC, Classic and Value Added Series fulfil a wide range of storage requirements Capacities from 210 to 6,000 2ml vials Advanced vacuum and insulation for maximum thermal performance Durable, lightweight aluminium construction and roller bases for easy mobility Storage solutions for vials and straws Easy access to store and retrieve samples Sample security with low-level alarm and lockable lids (padlock not supplied) XC Series Compact Cryosystems for vial or straw storage. With roller base and handle mounted low level alarm. Classic Series Medium capacity storage for vials in standard cryogenic boxes. With roller base and handle mounted low level alarm. Value Added Series Same as Classic Series but with the low level alarm built into a lid console. LN 2 Capacity (l) 2ml Vial Capacity XC / XC 34/ XC 47/ Classic 02 & Value Added Classic 4002 & Value Added Classic 6002 & Value Added

83 SANYO Vision on Incubation SANYO knows that you need more than good intentions to stay at the top. You are resolute in your determination to get the best results. But even if you excel in your profession you still need to rely on the equipment. Being innovative and ambitious garantees that you can perform at the highest level. You and SANYO a perfect match. SANYO CO 2 and Multigas Incubators provide the very best conditions for cell cultivation, from routine cell culture to the most critical applications. SANYO has pioneered the development of technologies, which set new standards for temperature and CO 2 control. In addition, SANYO s contamination control technology constantly helps to protect valuable samples, without downtime or compromise to the incubator s performance. SANYO has received FDA 510(k) clearance to market CO 2 and Multigas Incubators for in-vitro applications. CO 2 Incubators Multigas Incubators Multi Cell-Imaging Incubator Plant Culture Chambers Heated Incubators Cooled Incubators World Class Design Performance - SANYO CO 2 and Multi-gas Incubators offer outstanding control and rapid recovery of temperature and CO 2 /O 2 concentration to provide optimum conditions and reproducible results. Temperature - Direct Heat and Air Jacket technology (DHA) provides precise and uniform temperature control, with rapid response following door opening. Uniform temperatures (and CO 2 levels) are further enhanced by gentle fan circulation, which unlike convection methods of air circulation, is much less affected by incubator loading and other factors. CO 2 SANYO introduced reliable, long-life solid-state Infrared sensors and PID control of CO 2 injection to provide exceptional CO 2 stability and recovery times. Auto-calibration using room air eliminates drift and fan circulation ensures efficient distribution and uniformity of CO 2 inside the incubator. Note: Featured models are the MCO-18AIC/18M. Specifications vary between models for details, please refer to the individual model descriptions. The main heater provides precise temperature control. The bottom heater warms the distilled water and controls chamber humidity. The outer door heater prevents condensation on the inner door and facilitates quick temperature recovery after door openings. innovative 80

84 Your SANYO ambitious dynamic creative 81

85 SANYO Vision on Incubation Choice - SANYO design and manufacture a range of CO 2 and Multigas Incubators to meet a variety of application and user needs: MCO-80IC MCO-AIC MCO-18AIC MCO-5AC MCO-15AC MCO-175 MCO-18M MCO-5M InCu-VIEW Live 851 litres Large Scale Cell Culture CO 2 Incubator 195 litres Professional Cell Culture CO 2 Incubator 170 litres Professional Cell Culture CO 2 Incubator 49 litres Personal Cell Culture CO 2 Incubator 164 litres CO 2 Cell Culture Incubator 170 litres Water-Jacketed CO 2 Cell Culture Incubator 170 litres Professional Cell Culture Multigas (CO 2 /O 2 /N 2 ) Incubator 49 litres Personal Cell Culture Multigas (CO 2 /O 2 /N 2 ) Incubator 49 litres Multi Cell-Imaging Incubator Your SANYO Relative Humidity A removable water pan combined with an independent heater at the base of the incubator provides an efficient, cost effective method for maintaining elevated humidity levels. The humidifying pan can be easily removed and a water level sensor provides an easy maintenance system. Preventive Contamination Control - SANYO s InCu safe and SafeCell UV work in combination to provide the most effective protection against contamination during culturing, without downtime or affecting cultures. InCu safe Copper-Stainless Steel Alloy InCu safe copper-stainless steel alloy combines the corrosion resistance and durability of stainless steel with the germicidal properties of Copper. The InCu safe walls and shelves significantly reduce the risk of contamination developing on internal surfaces. SafeCell UV (U.S. Patent ) SANYO s SafeCell UV system with programmable, ozone-free UV lamp sterilises the chamber air, and water in the humidifying pan. The UV lamp is completely isolated from the cell cultures and unlike other methods; the SafeCell UV system does not trap contaminants inside the incubator or require the temporary removal of critical components. Note: Featured models are the MCO-18AIC/18M. Specifications vary between models for details, please refer to the individual model descriptions. 82

86 Large Scale CO 2 Incubator MCO-80IC secure innovative MCO-80IC 851 LITRES Large Scale Cell Culture CO 2 Incubator The MCO-80IC is ideal for culturing high volumes of patient samples, performing shortterm studies, and working with large volume cell culture apparatus. The MCO-80IC includes SANYO s advanced incubator technologies such as InCu safe interior, UV decontamination* and solid-state infrared CO 2 sensor with P.I.D. control to provide outstanding performance and anti-contamination control. The incubator also features exceptionally low CO 2 gas consumption for economic operation. Superior CO 2 and Temperature Control Horizontal Laminar Airflow System The MCO-80IC features a cross-shelf horizontal air flow system, which promotes optimum temperature uniformity throughout the incubator and contributes to rapid recovery after door openings. The conditioned air is directed evenly through the incubator using perforated side plenums made from SANYO s exclusive InCu safe copper-enriched stainless steel. The horizontal airflow helps to maintain uniform air circulation and even temperature distribution when samples are placed in the incubator. P.I.D. temperature control Limits temperature fluctuation to ±0.1 C. Infrared (IR) CO 2 sensor with P.I.D. microprocessor control Delivers precise control and fast CO 2 recovery characteristics. Exceptionally low CO 2 gas consumption rates Less than half of a similar competitor unit. * Optional UV sterilisation system for humidity reservoir. See page

87 Large Scale CO 2 Incubator MCO-80IC Your SANYO dedicated precise Frame heater Door glass heater Door frame heater Faster CO 2 Recovery & Lower CO 2 Consumption SANYO s large scale cell culture incubator has been designed specifically for critical applications in pharmaceutical, biotechnology and clinical investigation. Large chamber capacity applications require special consideration of gas usage and recovery. SANYO s proprietary IR sensor with P.I.D. CO 2 control algorithm is paramount to the industry s leading design. An optional inner door system (MCO-80ID) is also available to enhance these results further. Flexibility and Ease of Use Large capacity, 851 litre CO 2 Incubator with adjustable shelving provides flexibility in use. Accommodates roller bottle apparatus, 5 bottles wide x 7 bottles high (requires optional Mounting Ramp Kit, MCO-80RBS). Full view, double paned glass door allows clear observation of cultured samples. Large LED digital display and keypad for greater visibility and ease of set-up. Preventative Contamination Control Incubator interior, plenums and shelving made from SANYO s exclusive InCu safe germicidal, copper-enriched stainless steel. Heated glass door and door frame heater prevent condensation. Optional UV sterilisation system for humidity reservoir. Humidity Selection As standard, the MCO-80IC offers a choice of normal and high humidity modes for different application needs. For reliability and reduced maintenance the humidity reservoir heaters are located on the outside walls of the reservoir and are not susceptible to corrosion or scaling through contact with water. An optional auto-fill litre secondary water tank (Model MCO-80AS) provides an additional water supply to the humidity reservoir. 84

88 Performance data MCO-80IC Dimensions Temperature level recovery characteristics Temperature ( C) Door open for 30 sec. 34 Door open for 60 sec (min.) 1524 CO 2 level recovery characteristics 6 5 CO 2 level (%) Door open for 30 sec. Door open for 60 sec. 64 Unit: mm (min.) SANYO MCO-80IC Competitor Model Door Openings 0 2 x 2 x 0 2 x 2 x (Number per day) 30 sec 60 sec 30 sec 60 sec CO 2 Consumption 280 l/day 440 l/day 457 l/day 597 l/day 728 l/day 752 l/day (litres per day) 30kg CO 2 Cylinder 60 days 39 days 37 days 28 days 23 days 23 days Retention Time* * Test conditions: Set temperature = 37 C, set CO 2 = 5%, Ambient temperature = C. * All values are actual test values for reference only, and cannot be guaranteed in operation. Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Interior volume Net weight Heating method Temp. control system Temp. range Temp. uniformity Temp. fluctuation CO 2 control system CO 2 sensor CO 2 range CO 2 fluctuation Humidifying system Temperature CO 2 Humidity Shelves Contamination control Chamber humidity Shelf dimensions (W x D x H) Shelf material Maximum load Shelves Interior surface UV lamp (ozone-free) Access port Alarm system Remote alarm contacts MCO-80IC 986 x 853 x 40 mm 806 x 693 x 1524 mm 851 litres 275 kg Heater with fan air circulation. Horizontal laminar airflow. Microprocessor PID 5 C above ambient temp. to +50 C ± 0.5 C* ± 0.1 C* Microprocessor PID Infrared 0 to % ± 0.15%* Normal mode: Natural evaporation with humidifying water High humidity mode: Heated evaporation with humidifying water Normal mode: Over 80%RH High humidity mode: Over 90%RH 776 x 659 x 10 mm Copper alloy stainless steel 30 kg per shelf 5 (standard) Copper enriched stainless steel (except humidifying pan) UV System Kit for humidifying water reservoir only (Option) 2 x 40mm diameter (left and right side) High/low temperature, High/Low CO 2, Low water, Independent overheat protection, Door ajar, Remote alarm 30V DC, 2A N.O. N.C. Control Panel Options Shelf and brackets (InCu safe ) MCO-80ST Roller bottle rack mounting kit MCO-80RBS Automatic CO 2 gas cylinder switchover system MCO-80GC UV system kit MCO-80UVS Inner door kit MCO-80ID Automatic water supply system kit MCO-80AS ma Analogue output for MCO-80IC MCO-4MA Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 * Conditions: Ambient temperature: 25 C, Temperature setting: 37 C, CO 2 level setting: 5%, no load Specifications subject to change without notice. 85

89 CO 2 Incubator MCO-AIC Your SANYO reliable sensitive Professional Cell Culture CO 2 Incubator with UV sterilization The MCO-AIC Automatic CO 2 Incubator provides a stable cell culture environment where contamination control is a continuous process, not an inconvenience. Background Contamination Control The SANYO MCO-AIC is the world s first cell culture CO 2 incubator to employ continuous active background ultraviolet light sterilization in combination with the passive resistance of a copper-enriched stainless steel chamber to destroy contaminants in vitro without affecting cell cultures and without downtime. Eliminates HEPA Filter Scrubber and Decontamination Heat Cycle The MCO-AIC inhibits the growth of mycoplasmas, bacteria, molds, spores, yeasts and fungi without costly HEPA filter air scrubbers which accumulate contaminants in the chamber, or disruptive, high temperature decontamination schemes which can actually encourage growth of heat resistant thermophilic and hyperthermophilic microorganisms in vitro. As a result, the MCO-AIC offers a sensitive yet robust platform for short term, high-throughput drug discovery projects as well as intermediate and long-term cell culture investigations. High Performance In Vitro Modeling Stable temperature, humidity and CO 2 density are achieved through a combination of performance systems supervised by a centralized microprocessor 86

90 downtime none none contamination controlled controller complete with alarm, programming, calibration and diagnostic protocols exportable to remote databases through optional communications ports for compliance monitoring. Direct Heat, Air Jacket (DHA) Heating System The Direct Heat, Air Jacket (DHA) heating system eliminates the need for a conventional water jacket, while achieving temperature stability, uniformity and fast recovery following door openings. Elevated Humidity, Low Water Level Warning To avoid cell culture desiccation, the MCO-AIC maintains 95% RH at 37ºC through a combined forced air and natural evaporation method, which is enhanced by the DHA base heater and protected by an optical water level indicator to warn of low water in the removable humidity pan. A unique optical water level sensor automatically inserts into the humidity pan when filled and replaced. Performance data MCO-AIC Temperature Pull-up Characteristics Temperature Recovery Characteristics Humidity Recovery Characteristics Temperature ( C) Time (hr.) Temperature ( C) Door opening 30 sec. Door opening 60 sec. Time (min.) Humidity (%) RH Door opening 30 sec. Door opening 60 sec Time (min.) CO2 level (%) CO 2 Level Recovery Characterics Door opening 60 sec. Door opening 30 sec. 1 (same as 60 sec.) Time (min.) Temperature ( C) Temperature decrease characteristics when power failure occurs Ambient temp. C Time (hr.) 87

91 CO 2 Incubator MCO-AIC Options Shelf and brackets (InCu safe ) MCO-58ST Roller base MCO-RB CO 2 gas pressure regulator MCO-100L Automatic CO 2 gas cylinder switchover system MCO-21GC Extra inner doors MCO-ID Half tray MCO-35ST Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 MCO-AIC 195 LITRES Specifications Dimensions Front view Power cord outlet Side view Unit: mm Model Exterior Dimensions (W x D x H) Interior Dimensions (W x D x H) Gross Interior Volume Net Interior Volume Exterior Finish Inner Door Outer Door Cabinet Insulation Net Weight Temperature CO 2 Humidity Shelves Contamination control Access Port Heating System Combined Heating Elements Temperature Controller Temperature Display Temperature Range Temperature Uniformity CO 2 System MCO-AIC 770 x 708 x 900 mm 6 x 523 x 665 mm 215 litres, nominal 195 litres, nominal Polyester finished, baked-on zinc galvanized steel Tempered glass PMMA/PVC with integrated door heater Rigid polyurethane, CFC-free 106 kg Direct Heat, Air Jacket (DHA) with positive air flow 395 W distributed proportionally Microprocessor PID Digital, resolution to 0.1 C 5 C above ambient to +50 C, ±0.1 C ±0.25 C top to bottom CO 2 Range 0 to %, ±0.1% CO 2 Variation ±0.15% Ceramic based infrared CO 2 sensor with ON/OFF inject CO 2 Setpoint and Display Digital, control panel, resolution to 0.1% CO 2 Inlet Connection CO 2 Inlet Pressure Humidification Method Requires 4 to 6mm ID tubing 0.03MPaG Gentle air flow through duct, natural evaporation from humidity pan over base heater Relative Humidity 95% at 37 C, ±5% Water Level Sensor Shelf Dimensions (W x D x H) Maximum Load Each Shelf Shelves Decontamination, Programmable UV Lamp Alarm System Microbiological Filters Interior Surface Remote Alarm Contacts Communications Electrical Maximum Current Maximum Heat Emission Noise Emission Optical, with visual low water alarm 580 x 450 x 12 mm 5 kg nominal, 5 shelves standard 15 shelves maximum UV sterilization of air and humidity source 4 W, nanometer, ozone-free emission Three, 0.3 micron, 99.97% efficient Copper alloy polished stainless steel for germicidal protection 30mm with inner and outer rubber stoppers Over temperature, CO 2 deviation, low water, door ajar 30V, DC, 2 amps allowable RS232/RS485 data port (optional) 2-240V, 50Hz, AC 1.9 amps 1299 BTU/Hr (1370 kj/hr) 30 db (A scale) 88

92 SANYO has an outstanding reputation for reliability. We believe in minimize the risks first. And we never economize on materials to cut costs. Because we know that to accomplish your goals you need superior build quality and materials. You can depend on SANYO: the way we think about quality, is profitable for you. You and SANYO a perfect match. reliable SANYO VISION well-considered Universal design offers a distinct advantage in the model selection. With reversable inner and outer doors and a cabinet reinforced for stacking, a single SANYO-MCO-AIC offers the industry s most flexible installation option without added cost. The outer door latches and door heater cable are easily switched if a reverse opening is required. Cabinet knock-outs are pre-punched to eliminate drilling. SANYO Economics 89

93 CO 2 Incubator MCO-18AIC / MCO-18AICUV MCO-18AIC 170 LITRES stable Conventional recovery time: approx. 7 minutes CO2 level recovery characteristics (Door open for 30 seconds) On-Of control 2 PID control (MCO-18AIC) Time (Min) CO 2 level (%) CO2 level fluctuations in chamber when door openings of 30-second duration are made with 10-minute intervals Company A model with TC Sensor MCO-18AIC Time (Min) CO 2 level (%) MCO-18AIC: approx. 3 minutes* Professional Cell Culture CO 2 Incubator Faster CO 2 level recovery Fast recovery of the CO 2 level is due to the effective combination of an infrared CO 2 sensor and PID (Proportional, Integrated and Differential) control. This incubator offers a long-awaited performance level with a more stable CO 2 environment to reliably function for heavy usage situations that require frequent door openings. Preventive Contamination Control InCu safe interior chamber with fully rounded corners inhibits bacteria growth continuously. An automatic ultraviolet lamp (option) can also eliminate contaminants in the circulating air and water in the humidity pan without affecting cell cultures. The two powerful measures result in effective contamination control. Water Level Sensor The humidity pan has an optical water level sensor to warn of a low water level. Field-reversible Door The reversible door allows right or left opening depending on the installation space and how other peripheral equipment is positioned. Each corner of the door has a special grip for easier opening. *Maintaining uniform CO 2 levels is assured even with frequent incubator door openings 90

94 Options Shelf and brackets (InCu safe ) MCO-46ST Half tray MCO-25ST Roller base MCO-18RB CO 2 gas pressure regulator MCO-100L Automatic CO 2 gas cylinder switchover system MCO-21GC UV system kit MCO-18UVS2 Extra inner doors MCO-18ID Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 powerful Your SANYO performance Improved Temperature Stability with DHA System Three independently controlled heaters pius SANYO s proprietary air jacket structure provides a high-precision temperature environment. Ergonomic Design Low profile, stackable design for efficient use of available laboratory space. User-friendly door-mounted control panel is easy to use and access. Automatic CO 2 cylinder Switchover System (option) This system automatically switches from the primary to secondary gas cylinder when a CO 2 gas level drop in the chamber is detected. The in-use gas cylinder is confirmed on the control panel. Dimensions Front view Power cord outlet Side view Unit: mm Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Interior volume Net Weight Heating Method Temp. control system Temp. range Temperature CO 2 Humidity Shelves Contamination control Temp. uniformity Temp. controllability CO 2 control system CO 2 sensor CO 2 range CO 2 controllability Humidifying system Chamber humidity Shelves (W x D x H) Shelf material Maximum load Shelves Interior surface UV lamp (ozone-free) Access port Alarm system Remote alarm contacts MCO-18AIC / MCO-18AICUV 6 x 710 x 900 mm 490 x 523 x 665 mm 170 litres 93 kg Direct heat & Air jacket (DHA) Microprocessor PID 5 C above ambient temperature to +50 C (Ambient temp.: +5 C to 35 C) ±0,25 C* ±0,1 C* Microprocessor PID Infrared 0 to % ±0,15%* Natural evaporation by water in humidity pan over bottom heater (with water level sensor) 95 ± 5%RH 450 x 450 x 12 mm Copper Alloy stainless steel 7kg per shelf 4(standard) Copper Alloy stainless steel UV system kit (standard for MCO-18AICUV) 30 mm diameter High/low temperature, CO 2 level, door and UV lamp failure, independent overheat Overheat protection, 30V DC, 2A allowable * Conditions: Ambient temperature: 25 C, Temperature setting: 37 C, CO 2 level setting: 5%, no load. 91

95 CO 2 Incubator MCO-5AC MCO-5AC 49 LITRES Personal Series Compact CO 2 Incubator Patient Specific, Space Saving, Triple Stackable, Compact Design Preventive Contamination Control InCu safe copper-enriched stainless steel chamber, shelves, and air plenum inhibit surface contamination growth continuously. Airborne and water pan contaminants can also be prevented and continuously controlled by use of a patented SafeCell UV, ultraviolet decontamination method (optional). The ozone-free UV light is shielded from the cell culture area allowing for UV use while cultures remain in the incubation chamber. Improved Temperature Stability with DHA System Three independently controlled heaters plus SANYO s exclusive and patented air jacket construction provide high-precision temperature control, uniformity, and quick recovery after door openings. Ergonomic Design Even in a triple-stack configuration, the units are space-saving and low-profile, allowing for the most efficient use of laboratory space and also user-friendly access to the door-mounted control display panel. 92

96 Your SANYO When placed in triple stackable configurations (pictured below), this unit meets GLP (Good Laboratory Practice) requirements by helping to avoid patient-to-patient cross contamination in individualized patient-specific clinical incubation applications, such as in vitro fertilization and regenerative medicine techniques. personal specific Door-mounted control panel Automatic CO 2 Cylinder Switchover System (option) This system automatically switches from the primary to secondary gas cylinder when a CO 2 gas level drop in the chamber is detected. The in-use gas cylinder is confirmed on the control panel. Field-reversible Door The field-reversible door can be set up for right-hand or left-hand door openings, allowing for multiple configurations during laboratory installation. A special door handle allows for easier door grab and opening in triplestacked configurations. Control Panel Heater lamp Digital temperature indicator Digital CO 2 density indicator Reversible door Copper alloy stainless steel 1704 mm UV indicator CO 2 inject lamp Door lamp Water level alarm lamp Upper limit regulator Over heat lamp CO 2 gas supply line indicators (A/B)* Reversible door 568 mm Set key Digit shift key Calibration key Numeric shift key Gas supply line switching key* Alarm buzzer stop key Enter key * requires optional MCO-5GC 93

97 CO 2 Incubator MCO-5AC Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Interior volume Net Weight Heating Method Temp. control system Temp. range Temperature CO 2 Humidity Shelves Contamination control Temp. controllability CO 2 control system CO 2 sensor CO 2 range CO 2 controllability Humidifying system Chamber humidity Shelves (W x D x H) Shelf material Maximum load Shelves Interior surface UV lamp (ozone-free) Access port Air filter Alarm system Remote alarm contacts MCO-5AC 480 x 548 x 568 mm 350 x 378 x 375 mm 49 litres 49 kg Direct heat & Air jacket (DHA) Microprocessor PID thermistor sensor 5 C above ambient temperature to +50 C (Ambient temp.: +5 C to 35 C) ±0,1 C*1 On-off control TC sensor (direct chamber detection) 0 to % ±0,15%*1 Natural evaporation by water in humidity pan over bottom heater (with water level sensor) 95±5%RH 310 x 310 x 10 mm Copper Alloy stainless steel 4 kg per shelf 3 (6 max) Copper Alloy stainless steel UV system kit (option) 30mm diameter 0,3µm, Efficiency: 99,97% (for CO 2 ) High/low temperature, CO 2 level, door and UV lamp failure, independent overheat protection 30V DC, 2A allowable *1 Conditions: Ambient temperature: 25 C, Temperature setting: 37 C, CO 2 level setting: 5%, no load Dimensions Options Shelf and brackets (InCu safe ) MCO-30ST Roller base MCO-5RB CO 2 gas pressure regulator MCO-100L Automatic CO 2 gas cylinder switchover system MCO-5GC UV system kit MCO-18UVS2 Stacking kit MCO-18PS Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 Unit: mm Performance data MCO-5AC Temperature Pull-up Characteristics Temperature Recovery Characteristics Humidity Recovery Characteristics CO 2 Level Recovery Characterics Temperature decrease characteristics when power failure occurs Temperature ( C) Time (hr.) Temperature ( C) Ambient temp. C Door opening 30 sec. Door opening 30 sec. Door opening 30 sec Door opening 60 sec. Door opening 60 sec. Door opening 60 sec Humidity (%) RH CO2 level (%) Time (min.) Time (min.) Time (min.) Time (hr.) Temperature ( C) 94

98 CO 2 Incubator MCO-15AC MCO-15AC 164 LITRES Air Jacketed CO 2 Incubator SANYO s MCO-15AC CO 2 incubator was developed utilizing advanced technology for unprecedented temperature and CO 2 control. Chamber conditions are accurately maintained by the Microprocessor P.I.D. controller. The DHA Direct Heat & Air jacket was designed to surpass the performance of the traditional water jacket and eliminates the inconveniences of using water. Start-up is simple and easy with the automatic set-up function. What s InCu safe? InCu safe is our name for products using copper-alloyed stainless steel. Copper Alloyed Stainless Steel - SANYO s Concept Against Contamination Contamination is the worst enemy of laboratory work. When designing its new range of incubators, SANYO examined two methods commonly used to combat contamination: HEPA filters and copper. HEPA filters are efficient at removing bacteria in the air, but maintenance is demanding. Copper is effective against bacteria but corrosion is a problem; even a small spill of culture medium is enough to cause oxidation. SANYO s solution to the problem is copper alloyed stainless steel; a material that combines the bacteria killing properties of copper with the corrosion resistance of stainless steel. Copper Alloy Stainless Steel Kills Mycoplasma SANYO is proud to announce that InCu safe, the copper/stainless steel alloy used in the interior of its CO 2 incubators, kills mycoplasma. Mycoplasma is one of the most common causes of contamination found in cell culture and the source can often be traced back to contaminated laboratory apparatus. The InCu safe walls and shelves inside SANYO CO 2 incubators eliminate mycoplasma and significantly reduce the risk of contamination without emptying the incubator. 95

99 CO 2 Incubator MCO-15AC Heat lamp (HEAT) Digital temperature indicator Calibration key (CAL) Set key (SET) Door lamp (DOOR) Upper limit alarm temperature indicator (OVER HEAT) Alarm Buzzer stop key (BUZZER) Upper limit alarm Temperature setting control Entry key (ENT) Digital CO 2 concentration indicator CO 2 inject lamp (INJECT) Numerical value shift key Digit shift key Performance data MCO-15AC Middle middleshelf shelf Upper upper shelf shelf Measurement position Shelf position Upper shelf +0,03 +0,07 0,00-0,15 +0,05 Middle shelf 0,00 Lower shelf -0,05-0,02-0,05-0,03 +0, Condition: Ambient temp. C, Ambient humidity 45%, CO2 level setting 5,0%, Water humidity pan 2,0 litres 1 Day Drop method with E. Coli (ATCC8739) front lower shelf Front Lower Bacteria killing after 24 hours (Drop method) Species Stainless steel Copper Alloy (Type 304) Stainless steel Copper Alloy Stainless Copper (C11000) Stainless (Type 304) Escherichia coli (ATCC8739) 0% 99,928% Escherichia coli (IFO3301) 0% 99,847% Staphylococcus aureus (ATCC6538P) 0% 99,98% Bacillus subtilis (ATCC6633) 0% 99,997% Door heater Fan Side heater SSR (Solistade relay) Insulation Air jacket CPU Precision control & quick recovery. Direct Heat & Air (DHA) jacket system. The incubator has three sources of heat sides, door, and independent bottom heaters, all of which are located outside the chamber. The sealed air jacket and foam insulation maintain a uniform temperature. The DHA jacket design provides quick recovery for temperature after door openings. Independent controlled bottom heater SSR (Solistade relay) Independent control bottom heater The microprocessor controls the bottom heater independent from the sides and door heaters. By adjusting the bottom heater control, you can change the ratio, resulting in humidity control from about 93% to 98% RH. 96

100 Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Net weight Humidity CO 2 Temperature Heating method Temperature control Temperature range Temperature uniformity CO 2 control CO 2 range CO 2 variation CO 2 secondary pressure Humidifying system Chamber humidity Air circulation system Shelves Exterior finish Interior finish Door Inner door Insulation Power source Voltage Amps Breaker Alarm system Power consumption MCO-15AC 6 x 685 x 900 mm 490 x 505 x 665 mm 164 litres 78 kg Direct heat & Air (DHA) jacket system Microprocessor PID control (sensor: thermistor) Ambient temperature +5 C~50 C ±0,2 C (setting temperature: 37 C, ambient temperature: C) Microprocessor control (sensor : Thermal conductivity) 0 % ± 0,15% 0,03 bar Gentle air circulation 95% ± 5% RH (AT: C, 60% RH) Natural evaporation with water in humidity pan (stainless) Standard 3 Baked-on acrylic finish on galvanized steel Copper Alloy stainless round corner Baked-on acrylic finish on galvanized steel with door heater Tempered glass Foamed in place polyurethane (non CFC) 230/240 V 1,6 A 10A Audible and visual Alarm Temperature, CO 2, Door alarm (circulation fan and CO 2 valve OFF) Independent overheat protection circuit and sensor 380 W * Specifications subject to change without notice. Options Stackable function Due to the design and minimal weight one unit can be stacked on top of another using stacking kit MCO-18PS. This provides not only the space saving of a double unit but also the flexibility of independent chambers. Automatic setup By turning on the power and simply entering the temperature and CO 2 set points, you can walk away from the unit while the microprocessor takes over. The unit will attain set point and adjust itself to your required parameters. Rounded corners The interior chamber is constructed of Copper Alloy Stainless steel with rounded corners. All plenums, shelves, brackets are removable without use of tools. These design features provide an interior that is easily cleaned to reduce chances of contamination. Tray and brackets (InCu safe ) Half tray CO 2 gas pressure regulator Stacking kit Rollerbase MCO-45ST MCO-25ST MCO-100L MCO-18PS MCO-18RB Performance data MCO-15AC Dimensions Temperature decrease characteristics when power failure occurs Temperature Recovery Characteristics CO 2 Level Recovery Characterics Humidity Recovery Characteristics Unit: mm 97

101 CO 2 Incubator MCO-175 Your SANYO ultra-precise MCO LITRES Water Jacketed CO 2 Incubator CO2 level (V/V%) Humidity (RH%) PID control plus chamber direct sensing system maintains a high-precision temperature environment. Through the combination of a PID (Proportional, Integrated and Differential) control system for ultra-precise temperature control and a cabinet-air sensing system which accurately monitors inside temperature, this model exhibits exceptional precision within ±0,1 degree of the preset temperature. For the temperature sensor, a durable, ultraprecise PT sensor (Pt 100) is used. Automatic stop mechanism for Fan Motor and CO 2 valve. With this mechanism, the fan motor and CO 2 valve are automatically stopped when the door is opened. This minimises air flow from the chamber and reduces air contamination due to the mixing of air. CO 2 level recovery characteristics when dehumidifier is incorporated. CO 2 level recovery characteristics without dehumidifier shows CO 2 level in chamber A compact electronic dehumidifier plus a thermal conductivity CO2 sensor produces a high-precision CO2 environment Automatic control door heater The outer door incorporates a door heater that is automatically controlled. This prevents temperature differences between the chamber and the inner door, thereby preventing condensation on the inner door. SUS-304 Stainless steel with rounded corner structure Stainless steel featuring superior chemical resistance and a rounded corner structure are incorporated within the cabinet interior. The shelves, shelf supports and shelf support tabs are easily removable to allow thorough cleaning and sterilization. Specific Tube for CO 2 Gas A specific tube is used for supply and sampling of the CO 2. Featuring superior mold resistance and enabling autoclave sterilization, the tube conforms to the Japanese regulations for Medical and Health and Food Hygiene, eliminating causes of contamination. 98

102 Water Jacketed MCO-175 System The large size MCO-175 model incorporates a water jacketed system which takes advantage of the heat retention characteristics of water. Because there is no sudden temperature change or loss of temperature during power failure, a stable temperature environment is ensured. Options Temperature chart recorder Chart paper Stacking kit CO 2 pressure regulator MCO-101TR RP-CO MCO-175SB MCO-100L Water preservative agent MCO-100C (cleaner #1000) Extra shelf MCO-46ST Half tray MCO-25ST Dimensions Specifications Power cord outlet Unit: mm Model MCO-175 Exterior dimensions (W x D x H) 770 x 6 x 900 mm Interior dimensions (W x D x H) 490 x 505 x 690 mm Effective capacity 170 litres Net weight 108 kg Heating method Water jacketed Temperature control PID control (sensor: Pt.100 Ohm) Temperature uniformity ±0,2 C (setting temperature: 37 C, ambient temperature: C) Temperature range Ambient temperature +5 C~50 C CO 2 control ON-OFF control system (sensor: Humidity protected T.C.) CO 2 range 0 % CO 2 variation ± 0,15% CO 2 secondary pressure 0,03 bar Humidifying system Natural evaporation with water in humidity pan (stainless) Chamber humidity 95% ± 5% RH (AT: C, 60% RH) Temperature CO 2 Humidity Shelves Exterior finish Interior finish Door Inner door Insulation Air circulation system Standard 6 max. 19 Baked-on acrylic finish on galvanized steel Stainless steel - round corner Baked-on acrylic finish on galvanized steel with door heater Tempered glass Foamed in place polyurethane (non CFC) Gentle air circulation Power source Voltage Amps Breaker 230/240 V 1,4 A 15A Alarm system Audible and visual Alarm Temperature, CO 2, Door alarm (circulation fan and CO 2 valve OFF) Independent overheat protection circuit and sensor Remote alarm contact Power consumption 285 W * Specifications subject to change without notice. 99

103 Multi-gas Incubator MCO-18M reliable accurate MCO-18M 170 LITRES Automatic Air Jacket Multi-gas Incubator The MCO-18M automatic air jacket multi-gas incubator provides precise CO 2 and O 2 level controls to realise a stable cell culture environment. It features multiple-patented technologies to safely achieve in-vitro performance. Also, the MCO-18M has been cleared by the US FDA for In-Vitro Fertilization (IVF) use. Rapid Recovery Exceptional CO 2 recovery is obtained by the combination of IR sensor and P.I.D. gas injection control, which precisely regulates the injection of CO 2 to provide rapid response without overshoot. Also, SANYO s IR sensor uses no moving parts. Therefore, it is extremely reliable and the lifespan is long. Additionally, along with a zirconia O 2 sensor, P.I.D. control is used for fast O 2 level control. The N 2 gas bubbler in the water pan helps recover humidity level quickly after door openings. Easy-to-Access Double Inner Door System A double inner door system keeps gas consumption low and prevents outside air influx. An optional half tray adds greater flexibility. Improved Temperature Stability with D.H.A. System P.I.D. controlled 3-way heaters plus SANYO s proprietary D.H.A. (Direct Heat and Air jacket) provides a high-precision temperature environment, and minimises the risk of condensation and subsequent contamination. Water Level Sensor The humidity pan has an optical water level sensor to warn of low water level. Automatic Gas Cylinder Switchover System This system automatically switches from the primary to secondary gas cylinder when the O 2 gas level does not change while an injection valve is open. An optional gas switchover for CO 2 gas is also available. The in-use gas cylinder is confirmed on the control panel. 100

104 Options Shelf and brackets (InCu safe ) MCO-46ST Half tray MCO-25ST Roller base MCO-18RB CO 2 gas pressure regulator MCO-100L Automatic CO 2 gas cylinder switchover system MCO-21GC UV system kit MCO-18UVS2 Your SANYO Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 Applications In-vitro/micro fertilization Gene research ES cell research Regenerative medicine research Cancer research Biological research Cell test Dimensions Front view Side view Preventive Contamination Control InCu safe copper enriched stainless steel chamber with coved corners inhibits bacteria growth on its surface continuously. Airborne and water contaminants in the water pan can also be eliminated by patented SafeCell UV, an automatic ozone-free ultraviolet lamp (option), without affecting cell cultures Specifications 580 Power cord outlet Unit: mm Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Interior volume Net Weight Heating Method Temp. control system Temp. range Temperature CO 2 O 2 Temp. uniformity Temp. controllability CO 2 control system CO 2 sensor CO 2 range CO 2 controllability O 2 control system O 2 sensor O 2 range O 2 controllability MCO-18M 6 x 710 x 900 mm 490 x 523 x 665 mm 170 litres 97 kg Direct heat & Air jacket (DHA) Microprocessor PID 5 C above ambient temperature to +50 C (Ambient temp.: +5 C to 35 C) ± 0,25 C 1 ± 0,1 C 1 Microprocessor PID Infrared 0 to % ± 0,15% 1 Microprocessor PID Zirconia 1 to 18 % / 22 to 80% ± 0,2% 1 Humidifying system Chamber humidity Shelf (W x D x H) Shelf material Maximum load Shelves Interior surface UV lamp (ozone-free) Access port Alarm system Remote alarm contacts Stacking plate for 18M + 18M is included in the main body 1) Conditions: Ambient temperature: 25 C, Temperature setting: 37 C, CO2 level setting: 5%, O2 level setting 5%, no load. Humidity Shelves Contamination control Natural evaporation by water in humidity pan over bottom heater (with water level sensor) 95 ± 5% RH 450 x 450 x 12 mm Copper Alloy stainless steel 7 kg per shelf 4 (standard) Copper Alloy stainless steel UV system kit (option) 30 mm diameter High/low temperature, CO 2 level, door and UV lamp failure, independent overheat protection 30V DC, 2A allowable 101

105 Multi-gas Incubator MCO-5M MCO-5M 49 LITRES Professional Cell Culture Compact Multi-gas Incubator The MCO-5M automatic air jacket multi-gas incubator provides precise CO 2 and O 2 level controls to realise a stable cell culture environment. It features multiple-patented technologies to safely achieve in-vitro performance. Also, the MCO-5M has been cleared by the US FDA for In-Vitro Fertilization (IVF) use. Rapid Recovery Exceptional CO 2 recovery is obtained by the combination of a unique P.I.D. TC sensor with long lifespan. Additionally, along with a zirconia O 2 sensor, P.I.D. control is used for fast O 2 level control. The N 2 gas bubbler in the water pan helps recover humidity level quickly after door openings. Water Level Sensor The humidity pan has an optical water level sensor to warn of low water level. Automatic Gas Cylinder Switchover System This system automatically switches from the primary to secondary gas cylinder when the O 2 gas level does not change while an injection valve is open. Optional Switchover for CO 2 gas is available. Preventive Contamination Control InCu safe copper enriched stainless steel chamber with coved corners inhibits bacteria growth on its surface continuously. Airborne and water contaminants in the water pan can also be eliminated by patented SafeCell UV, an automatic ozone-free ultraviolet lamp (option), without affecting cell cultures. Improved Temperature Stability with D.H.A. System P.I.D. controlled 3-way heaters plus SANYO s proprietary D.H.A. (Direct Heat and Air jacket) provides a high-precision temperature environment, and minimizes the risk of condensation and subsequent contamination. 102

106 TRIPLE STACKABLE Door-mounted control panel Copper alloy stainless steel 1725 mm Your SANYO Reversible door precise Reversible door 575 mm practical Specifications Model Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Interior volume Net Weight Heating Method Temp. control system Temp. range Temperature CO 2 O 2 Temp. uniformity Temp. controllability CO 2 control system CO 2 sensor CO 2 range CO 2 controllability O 2 control system O 2 sensor O 2 range O 2 controllability MCO-5M 480 x 548 x 568 mm 350 x 378 x 375 mm 49 litres 49 kg Direct heat & Air jacket (DHA) Microprocessor PID 5 C above ambient temperature to +50 C (Ambient temp.: +5 C to 35 C) ±0,25 C 1 ±0,1 C 1 Microprocessor PID Thermal Conductivity (P.I.D.) 0 to % ± 0,15% 1 Microprocessor PID Zirconia 1-18%, 22-80% ±0,2% 1 Humidifying system Chamber humidity Shelf (W x D x H) Shelf material Maximum load Shelves Interior surface UV lamp (ozone-free) Access port Alarm system Remote alarm contacts Stacking plate for 5M + 5M is included in the main body 1) Conditions: Ambient temperature: 25 C, Temperature setting: 37 C, CO2 level setting: 5%, O2 level setting 5%, no load. Humidity Shelves Contamination control Natural evaporation by water in humidity pan over bottom heater (with water level sensor) 95 ± 5%RH 310 x 310 x 12 mm Copper Alloy stainless steel 4 kg per shelf 3(standard); (6 max) Copper Alloy stainless steel UV system kit (option) 30 mm diameter High/low temperature, CO 2 level, door and UV lamp failure, independent overheat protection 30V DC, 2A allowable Dimensions Front view Access port Side view Options Shelf and brackets (InCu safe ) MCO-30ST Roller base MCO-5RB CO 2 gas pressure regulator MCO-100L Automatic CO 2 gas cylinder switchover system MCO-5GC UV system kit MCO-18UVS2 Data Acquisition System (DAQ) Interface Software MTR-480 MTR-00 Unit: mm 103

107 InCu-VIEW Live In vitro Live Cell Imaging Jointly developed with Olympus Co., Ltd. All microscope and stage operations are operated remotely via the PC Software. MCOK-5M 49 LITRES Multi Cell-Imaging Incubator Observation and recording of embryos and cells - in culture. All-in-one multi-gas incubator with integrated optical microscope Culture, observation and time-lapse recording of cells and embryos under controlled environmental conditions No need to remove samples for observation Record multiple samples and viewing points Reduced risk of contamination LED Optical source Sample stage InCu-VIEW Live is a Multi Cell-Imaging Incubator with an integrated optical microscope for the culture, observation and time-lapse recording of embryos and cells. Samples are maintained under tightly controlled environmental conditions with reduced risk of contamination. The integrated design eliminates the need to remove cell cultures or embryos from the incubator for observation and all microscope operations are controlled remotely minimising the number of door openings. 104

108 Options CO 2 gas pressure regulator Automatic CO 2 gas cylinder switchover system MCO-100L MCO-5GC reliable Your SANYO innovative accurate Dimensions ø Applications IVF and Embryology Stem Cells Regenerative Medicine Cell Culture Toxicology and Comparative Studies Unit: mm SANYO 49 litre Multi-gas (CO 2 /N 2 /O 2 ) Incubator provides a precise and stable culture environment. Integrated Olympus microscope with a choice of phase contrast or relief contrast optics for optimal sample imaging. Observe and record embryo or cell development with simultaneous time-lapse recording of up to 12 samples with 10 viewing points per sample. Embryo tracking automatically re-aligns stage position to follow embryo movement. 10x Objective provides approx. 250x enlarged image when displayed on a 17 monitor. 0.1W White LED optical source does not effect temperature control. The light source is only on during image capture minimising exposure for cells or embryos. High-precision motorised stage accommodates most commonly used culture dishes and flasks with no disturbance to samples. MTR Software provides easy set-up and automated operation including auto-focus, fixed point observation, analysis and time-lapse recording. Sample and culture parameters are also recorded. Two microscope system proposals for optimal sample imaging: - Phase-contrast system MCOK-5M: Integrated with phase-contrast microscope for optimal observation of cells or tissues with thicknesses of less than 30 µm in both adhesion and floating systems. - Relief-contrast system MCOK-5M(RC): Integrated with relief-contrast microscope for optimal observation of thicker samples such as embryos and ES cells. 105

109 Environmental Test Chamber MLR-351 / MLR-351H MLR-351H 294 LITRES secure Versatile Environmental Test Chamber Graphic LCD provides easier operation Programmable temperature, lighting and humidity function (MLR-351H) Microprocessor PID control and Refrigeration Capacity Control Data logging function The wide variety of temperatures and lighting patterns that are essential in various research and testing can now be accurately reproduced and controlled. And humidity control too! Microprocessor PID control of temperature and humidity (0 C to +50 C, 0 to,000lux and 55 to 90%RH resp.) create the optimum environments for various applications. Microprocessor PID and Refrigeration Capacity control minimise temperature fluctuations and thereby improve temperature control. This allows superior precision experiments plus energy and electricity savings. Programmable temperature function is perfect for temperature cycle and vernalization treatment research. 12-step programmes x 10 patterns can be stored. Selectable clock mode or timer mode. Multiple programmes can be connected (Join mode). Starting day and time of operation can be programmed. Operation data of approximately last 2 weeks (6-minute intervals) can be automatically recorded. The data can be viewed on the control panel. The data can be transmitted to a PC (CSV data via RS-232C, interface board MTR-480 required). Easy calibration: temperature and humidity can be calibrated easily through the control panel. 106

110 reliable accurate Your SANYO Applications: Plant growth Culture of plant cells, tissue and organs Acclimatization and rearing of plants Incubation and rearing of insects Electronic testing Food testing Small and lightweight, high-molecular membrane-type humidity sensor also boasts a high degree of accuracy and reproducibility. Of the newest high-molecular membrane type, the humidity sensor accurately measures chamber humidity (MLR-351H only). Control Panel Graphic LCD panel with pop-up menu function on control panel provides more visual display and allows intuitive operation. Pop-up menu Controls for High & Low temp. alarm Menu button Graphic LCD Control for LCD contrast Character input keys Selection & Enter keys 107

111 Environmental Test Chamber MLR-351 / MLR-351H Switch box LCD Control panel Door switch Air intake Side door fluorescent lamps Shelves Inner door Main door Air outlet Power switch Evaporation tray Casters and adjustable legs Performance data MLR-351 / MLR-351H Pull down, Pull up performance (The chamber temperature of center) (ST) LS0 LS2 LS4 LS5 LS1 LS3 108

112 Specifications Model MLR-351/351H Dimensions Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Exterior Interior Door Inner door Shelves Access hole Casters Air circulation Compressor Evaporator Refrigerant Heater Defrosting system Temperature range Lighting Temperature Humidity (MLR-351H) Temperature distribution Temperature fluctuation Temperature control Lighting range Control system Control range 760 x 700 x mm 5 x 490 x mm 294 litres Painted steel Stainless steel, paired glass window on right and left sides (370 x mm) Painted steel, front, left, and right side Paired glass door 5pcs. PE coated steel wire (bottom shelf with stainless steel cover), adjustable 40 mm dia. 1x (chamber top position) 4pcs. Forced air circulation Fully hermetic, 325W output Fin and tube type R404A 340W Automatic defrost (3 patterns), manual defrost 0 C to +50 C (Lamps off) MLR C to +50 C (Lamps off) MLR-351H +10 C to +50 C (Lamps on) MLR-351/MLR-351H ±1,0 C (lamp off) ±2,5 C (lamp on) ±0,3 C PID microprocessor control + refrigeration capacity control lux Max. 6 selectable light levels Fluorescent lamp 40W x 15pcs. Ultrasonic PID control 55-90% RH overall (see graphs) Unit: mm Program Function Alarms Temperature, light (MLR-351) Temperature, light and humidity (MLR-351H) 12 steps (10 patterns), 98 cycle or limitless Clock mode: 00:00 23:59 Timer mode: 00:01 99:59 Temperature alarm High and low temperature limit Humidity alarm Humidity Control Range (MLR-351H only) *note: When unit is continuously below +10 C the evaporator may become frosted and the unit efficiency will decline resulting in a chamber temperature increase. Regular inspection is recommended. Humidity (%RH) All fluorescent lamps off (LS 0) All fluorescent lamps on (LS 5) Controllable range 70 Controllable range Set temperature ( C) Set temperature ( C) Option Interface MTR-480 SANYO VISION 35 million yen SANYO provided environmental education to children at 40 schools through the Energy Evolution project for Elementary Schools Grants provided by the SANYO Think GAIA Foundation reached at total 35 million yen over five years education is the key 109

113 Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-553 / High-precision Temperature Environment SANYO s MIR cooled incubators have been recognized as exceptional units suitable for a wide range of applications. The wide variety of temperatures that are essential in research, environmental studies and testing can now be accurately reproduced and controlled. Microprocessor Control SANYO Refrigerated Incubators incorporate a high precision microprocessor temperature control combined with a heater P.I.D. and compressor ON-OFF system. This system has a feed forward function that inputs the operating conditions of the compressor beforehand, ensuring accurate temperature control for the chamber. In a wide temperature range, the heater P.I.D. exhibits temperature fluctuation up to 0.2 C, and the Compressor ON-OFF controls precisely ±1 C. In addition, the fluctuation of temperature uniformity in the chamber is within ±0.5 C, allowing a full range of precise experimentation from microorganism cultures to various types of incubation and testing. Energy Savings Because a heater output and compressor on/off are microprocessor controlled, optimum automatic operation according to ambient temperature and fluctuation of chamber load is possible, resulting in energy savings. Foamed-in-place Rigid Polyurethane Insulation HCFC-free foamed-in-place polyurethane is used for the chamber because of its high thermal retention and energy saving properties. Triple-pane Glass Observation Window plus 15W Fluorescent Lamp An easy-to-observe triple-pane glass observation window and 15W fluorescent lamp are provided for sample observation during experimentation. When observation is not required, an optional light shielding plate (MIR-154/MIR-254) can be easily attached. 110

114 MIR-162 / MIR-262 Your SANYO objective precise Alarm and Security System to Protect Sample Safety Automatic Setting Temperature Alarm When the chamber temperature deviates more than ±2.5 C, all digits of the digital indicator flash. Ten minutes later a buzzer will sound. This system also automatically allows programmed operation or setting value changes. Independent Over-temperature Protection Device This incubator incorporates an excessive temperature prevention circuit that protects experimentation materials in the rare event that a temperature abnormality does occur. Isolated from the main circuit, this exclusive circuit and sensor operate even if the temperature sensor or microprocessor malfunction, activating a buzzer notification. This system turns off the heater and chamber fan motor when over temperature is detected, and turns off the compressor when under temperature is detected. Remote alarm contacts are provided for monitoring alarm from a remote location. Programmed Memory Back-up Mechanism Should the power source be interrupted due to power failure or other event, programmed data remains stored in memory. When the power source is restored, operation can be continued according to the predetermined program. Key Lock A key lock switch is provided so that settings may not be changed unintentionally. Trouble Monitor (Self Diagnostic Function) Should a malfunction occur, the location of the malfunction can be digitally indicated, allowing quick operator response. 111

115 Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-553 / MIR LITRES MIR LITRES New MIR-154 and MIR-254 Cooled Incubators Wide Range of Applications The MIR-154 and MIR-254 refrigerated incubators are ideal in testing applications such as: Industrial testing in the electrical, machinery, textile industries Chemical testing e.g., storage, stability, acid/alkali, durability Food industry for packaging, quality control and stability Testing for waste water, BOD, soil testing Microorganism culturing Germination experiments Flexibility The SANYO MIR series offers accurate temperature control and uniformity over a wide range of temperatures, making them suitable for various applications. The MIR-154 and MIR-254 are programmable with 12 step, 10 program capability. Wide temperature range that goes up to +60 C Excellent temperature uniformity Intuitive Operation with New LCD Display Easy operability by LCD display and pop up menu 24 hour mode and timer mode are selectable Combination of multiple programs in join function Booking of operation start date and time Operation data can be autorecorded and graphical displayed. Data Can be Sent to PC Using Optional Communication Interface (MTR-480) Lights Timer Control On-Off programmed timer control for initially equipped fluorescent light (15W x 1pc) is available. Optional light addition kit (MIR-L15) can add three more fluorescent lights into the chamber ceiling, giving approx. 3000lux at 30cm below from the light sources. Improved Usability Modern design and reversible door Improved gentle air circulation that reduces media drying Full alarm package 112

116 MIR-162 / MIR-262 Programmable operation with microcomputer control Program input is simple. The MIR cooled incubators accommodate a range of diversified experimentation requirements, and are ideal for experimentation during night time or holidays, experimentation that requires settings to be changed, and microorganism culture and preservation. Constant operation mode without step operation is also available. Program examples 3-Step Repeat Operation Temperature (T1, T2, T3) and Time (H1, H2, H3) are set. Then, limited repeating operations (from 1 to 99 times) or continuously repeated operations are conducted. After a limited repeating operation has been completed, constant operating temperature T0 is retained. Application: Optimum for repeated experiments in which 3 different temperatures and times are combined. MIR LITRES 3-Step to constant Operation With a temperature of T1, T2, and T3, operation is conducted using time H1, H2, H3 respectively. Then, constant operation temperature T0 is retained. Application: Optimum for experiments that require consistent 4-step temperature increases and decreases. Performance data MIR-154 / MIR-254 / MIR-553 MIR-154 Chamber pull-down/pull-up characteristics (Outside air temperature C Power source: AC 100V/50Hz) Chamber temperature ( C) Ambient temperature C Time (Hr) MIR-254 Chamber pull-down/pull-up characteristics (Outside air temperature C Power source: AC 100V/50Hz) Chamber temperature ( C) Chamber pull-down/pull-up characteristics (Ambient temperature C Power source: AC100V/50Hz) Chamber temperature ( C) MIR Time (Hr) 6 Ambient temperature C Time (Hr) 6 Ambient temperature C Pull-down characteristics for thermal load in chamber (Outside air temperature 35 C Power source: AC 100V/50Hz) Chamber temperature ( C) Ambient temperature 35 C Chamber thermal load 1W Chamber thermal load 75W Chamber thermal load 0W Time (Hr) Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35 C Power source: AC100V/50Hz) Chamber temperature ( C) Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35 C Power source: AC100V/50Hz) Chamber temperature ( C) Ambient temperature 35 C Chamber thermal load 225W Chamber thermal load 75W Chamber thermal load 0W Time (Hr) Ambient temperature 35 C Chamber thermal load 300W Chamber thermal load 0W Chamber thermal load 100W Time (Hr) 2-Step Repeat Operation Using a temperature of T1 and T2, operation is repeatedly conducted (using time H1 and H2). Application: Optimum for day and night cycle operations of plant material or quality testing for chemicals, foods and samples. 2-Step to constant Operation With a temperature of T1 and T2, operation is conducted using time H1 and H2. Then, constant operating temperature T0 is retained. 1-Step to constant Operation With a temperature of T1, operation is conducted using time H1. Then, constant operating temperature T0 is retained. Application: Optimum for automation and labour savings while performing bacteria inspection from culture to preservation, and from preservation to culture. Options (MIR 154 and 254 only) Stacking kit (only for MIR-154) Door Padlock Bracket (Padlock not supplied) Additional Illumination kit Door Window Blanking Plate for MIR-154 for MIR-254 Communication Interface MIR-S154SB MIR-LP MIR-L15 MIR-154BP MIR-254BP MTR-480 *The data shown above are taken with the fluorescent lamp turned off. *Characteristics may vary depending on the product or operating conditions. 113

117 Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-553 / MIR LITRES MIR LITRES Heated Incubators Microcomputer PID Control + Air Jacketed System Microcomputer PID control and air jacketed system gives precise temperature control within the chamber. Temperature accuracy is within ±0,2 C (at 37 C) and temperature uniformity is within ±1 C (at 37 C). Microcomputer Timer Function An accurate microcomputer timer is fitted to allow experiments up to 99 hours and 59 minutes. Desired start time is set by an automatic start (delay function). The program activates a buzzer when a set time is over and keeps a set temperature after an operation finishes. Various operation patterns can be set by utilizing these functions. Temperature Control Range- Ambient Temperature +5 C~80 C (AT C) SANYO heated incubators allow incubation at normal temperature to high temperature. Advanced Design Control panel uses a touch keyboard and an easy-toread green LED display. Temperature and time are shown respectively by digital displays. Durable stainless steel (SUS-304) for interior cabinet. Performance data MIR-162 / MIR-262 Temperature uniformity data MIR MIR-262 Temp. ( C) Measured temp. by sensor Temp. at the middle of chamber Temp. ( C) Measured temp. by sensor Temp. at the middle of chamber Temperature pull-up speed: C to 60 C Approx. 70 minutes. (ambient temperature C, no load) Time (min.) Time (min.) 114

118 MIR-162 / MIR-262 Specifications Model Exterior dimensions: (W x D x H) Interior dimensions: (W x D x H) Effective capacity: Exterior finish: Interior finish: Door: Shelves: Insulation: Circulation system: Compressor: Evaporator: Condenser: Defrosting system: Heater: Temp. setting indication Temperature control Temperature sensor Autom. setting temp. alarm Over temp. protection device Programmed operation Temperature range Timer Temperature controllability Temperature uniformity Power source: Voltage Interior lamp Data log function Net weight Accessories Cooled incubators Heated incubators MIR-154 MIR-254 MIR-553 MIR-162 MIR x 580 x 1018 mm 700 x 580 x 1618 mm 800 x 832 x 1810 mm 580 x 595 x 8 mm 730 x 645 x 870 mm 6 x *386 x 555 mm 6 x *386 x 1088 mm 640 x 550 x 1160 mm 450 x 460 x 450 mm 600 x 510 x 500 mm 123 litres 238 litres 406 litres 93 litres 153 litres Painted steel Baked acrylic finish on galvanized steel Stainless steel SANYO Galvanized steel withblue baked on finish, Planet triple-pane glass Galvanized steel with baked Baked acrylic finish on galvanized steel observation window on finish, triple-pane glass with observation door PE coated steel wire, adjustable Stainless steel, stainless wire Foamed-in-place rigid polyurethane Glass wool Forced air circulation Natural convection Hermetic type - Output 150W Output 250W Output 300W - Fin and tube type, forced circulation - Wire and tube type Fin and tube type, forced air - cooling system Automatic timer defrost Manual start, automatic finish, - Manual start, automatic finish, natural vaporisation of drain water natural vaporisation of drain water Cord heater Cord heater Cord heater Sheathed heater Sheathed heater 141 W 218 W 332 W 0 W 300 W Digital setting with key lock digital display Microprocessor PID system, (when compressor operates, ON/OFF control) Microprocessor PID system Thermistor When temperature deviates approx. ±2,5 C, visual and audible alarm (MIR -154 / MIR-254 only) Visual and audible alarm 12 steps, 10 programs. Repeat from 1-98 times or continuous repeat. 3-step repeat from 1-99 times. - Clock mode / Count down mode. Settable program start date and time. Continuous repeat 1 step Program connection mode available. Time setting increment: 1 min 0,5~99,5Hr (program memory back up function approx. 5 hours) -10 C +60 C -10 C ~ +50 C + 5 C ~+80 C (AT C) - Automatic timer with delay function 00:00 ~ 99:59 hr:min ±0,2 C at heater PID control (Temp. setting 50 C, ambient temp. C, no load) ± 0,2 C (up to 60 C) ± 0,5 C (60-80 C) ±1 C at compressor ON/OFF control (Temp. setting 5 C, ambient temp. C, no load) ±0,5 C (Temp. setting 37 C, ambient temp. C, no load) ± 1 C (Temp. setting 37 C, ambient temp. C, no load) 230/240 V / 50 Hz 230/240 V / 50Hz 230/240 V / 50 Hz 230/240 V / 50 Hz 230/240 V / 50 Hz Controllable within program Chamber light: 1 x15w fluorescent 15 W x 1, fluorescent lamp, - (Light operation only when set temperature = +5 to +50 C) manual controllable See also additional optional Illumination Kit On-board storage of typically 2 weeks recorded data with - - chart displayed on LCD 78 kg 108 kg 5 kg 44 kg 61 kg - - Key 1set - - * Specifications subject to change without notice. * MIR-154/MIR-254 minimum depth 370mm. Dimensions MIR-154 MIR-254 MIR P30x11= P30x11= Unit: mm MIR Unit: mm MIR

119 Orbital Shaker MIR-S100 Revolution number/time display unit Numeric value shift key ENT key SET key START/STOP key START/STOP key RPM indicator lamp TIME indicator lamp Digit shift key intelligent MIR-S TO 500 RPM Compact & High-Speed Orbital Shaker The SANYO MIR-S100 orbital shaker delivers superior performance and functions in a compact, low-vibration design. Low vibration, low noise Compact design, intelligent operation Easy installation in SANYO incubator or growth chamber E. coli bacteria proliferation comparison E. coli bacteria transformation test in which bacteria cultivation continues until OD660 turbidity factor reaches 0.8. Cultivation time: approx. 5 hours at 0 rpm; approx. 2.5 hours at 400 rpm OD660 50ml tube; culture medium: 8ml/0 rpm rpm 50ml tube; culture medium: 8ml/400 rpm rpm Difference in cultivation 0.2 time by rpm Cultivation time (hr.) Bacteria sample: IFO3972; Culture medium: LB; Cultivation temperature: 37 C High-speed shaking - The MIR-S100 offers high-speed shaking from 50 to 500 rpm, which significantly reduces waiting time for cultures. Easy operation with MIR/MLR models - Can be installed in the MIR-154/ 254/553 and MLR-351. Control panel located in center of unit enables checking of indicators through the window of the MIR/MLR. Soft start - Gradually accelerates until reaching the preset number of revolutions so that samples inside flasks and test tubes are not spilled or foamed. Three levels of acceleration speed can be selected. Timer - Indicates time of operation from 0 to 99.9 hours in increments of 0.1 hour (6 minutes). Integrated operating time display - Displays the integrated operating time (which can be checked in the function mode). Key lock - Locks the keys on the control panel to avoid accidental function selection. 116

120 No. of units that can be installed MIR unit MIR units MIR units MLR units * The optional Mounting Kit is required for installation. * Please refer to the instruction manual for details before use. reliable Options Shaking platform MIR-38PFN Threaded hole diameter: 10 32UNF Threaded hole pitch (longitudinal): mm Threaded hole pitch (lateral):.65 mm Test tube rack for various tubes MIR-4SC Mounting kit MIR-15FP for use with MIR-154/254/553 and MLR-351 Clamps for flasks MIR-51FC for 50 ml flask MIR-101FC for 100 ml flask MIR-1FC for 0 ml flask MIR-301FC for 300 ml flask MIR-501FC for 500 ml flask MIR-1001FC for 1000 ml flask MIR-01FC for 00 ml flask Specifications 1 85 Auto recovery after power interruption - Automatically recovers after power interruption, and indicates that power interruption has occurred. Speed error alarm - Indicates an error when the number of revolutions does not reach or exceeds the preset value. Motor overload protection circuit - Detects over-current and automatically stops operation. Indicates an error when overload is applied to the motor. Sturdy stainless steel finish - Equipped with a cover made of stainless steel with hair line finish to facilitate cleaning. 10 Unit: mm Dimensions Front view Power cord Top view Power cord attachment position Rear view Model Exterior dimensions (W x D x H) Casing Shaking platform dimensions (W x D) Shaking platform Shaking method Amplitude (orbiting motion diameter) Shaking speed Allowable load weight Number of acceptable flasks Display unit Motor Ambient service condition Net weight MIR-S x 305 x 1 mm Main body: Baked-on acrylic finish galvanized steel Cover: Stainless steel SUS304 with hair line finish 380 x 250 mm Copper-enriched stainless steel (sold separately) Orbiting motion mm 50 to 500 rpm 5 kg 100 ml Erlenmeyer flask: ml Erlenmeyer flask: 6 Three-digit digital LED (speed/time changeable) Brushless DC motor 0 to 60 C 15 kg * Appearance and specifications are subject to change without notice. 117

121 SANYO Vision on Sterilisation SANYO recognizes that in order to excel you must be strong, focused and balanced. We focus on that vision by creating equipment that strikes a strong balance between cost and materials, design and usability. So that you can focus on accomplishing your goals. You and SANYO a perfect match. SANYO Portable Laboratory Autoclaves - Accurate, efficient temperature control. Easy-to-use functions. Portability so these Autoclaves go with you, wherever that may be. Above all these Autoclaves feature a wealth of security features to ensure the safety of the user and the material inside. What more could you want from an Autoclave! With generous capacities of up to ml flasks (MLS-3781L) and sterilisation temperatures up to 135 C, we give you two important reasons why your next autoclave should be a SANYO autoclave. For safe use of our new MLS-37 series, precautions and operating instructions are given by voice guidance. The working conditions, that are shown on the control panel, can be printed by a optional line thermal dot printer for record-keeping, management and storage. Two ranges of portable Autoclaves designed for the individual laboratory or user. Autoclaves Laboratory Autoclaves Tabletop Autoclaves Laboratory Ovens STURDY Autoclaves Class B and Class S Models - The Autoclave Sterilizer is ideal for dental and general laboratory use. Two sizes are available, 16L and 24L capacities, both having microprocessor control and are available as Class B or Class S models. SANYO MOV Laboratory Ovens - SANYO has always aimed to provide research support equipment that offers complete satisfaction to suit its users. Inspired by the search for even higher precision and greater flexibility of control, SANYO presents the MOV series of Laboratory Ovens; accurate, high-temperature equipment for scientific research. focused 118

122 strong Your SANYO individual 119

123 Autoclaves MLS-3751L / MLS-3781L MLS-3751L 50 LITRES MLS-3781L 75 LITRES Compact design In-Lab Autoclaves Researchers waste valuable time and energy when limited to using a centralized building autoclave. Installation and maintenance of central autoclaves are not only costly but time consuming. SANYO offers two solutions: The MLS-3781L and MLS-3751L portable autoclaves are designed for individual lab use and can be conveniently wheeled from one lab to another. Model MLS-3751L has a low enough profile to be stored under a lab bench when not in use. MLS-3751L Load example MLS-3781L Load example Surprisingly Large Chamber Despite the compact outer dimensions of these autoclaves, they store 8 (MLS-3751L) or 12 (MLS-3781L) 1,000ml flasks. The MLS-3751L has two baskets, and the larger MLS-3781L has three. ø370mm Eight 1000ml flasks Twelve 1000ml flasks Compact Design, Swing-up Lid for Easy Access Both SANYO models can be easily installed in minimal space. A swing-up lid provides effortless access for loading and unloading test tubes, flasks and lab instruments. 1

124 Your SANYO reliable individual Setting example Cycle Program Steriliz. Steriliz. Heat-retent. Temp. Time Temp. 1. Sterilizing 121 C 27 min. 2. Sterilizing/Keep Warm 121 C 27 min. 50 C 3. Melting/Keep Warm 100 C 30 min. 50 C 4. Instrument Sterilizing 135 C 3 min. 1. Sterilizing For water, culture media, reagents and other fluids. After completion and cooling to a selected temp., air is expelled automatically through the exhaust valve. Sterilizing temp.: 115 C to 135 C Timer: 1 to 300 min. Exhaust temp.: 0 C to 45 C. Handle Scalding prevention guard Newly designed handle lets users open and close the lid easily with one hand. The conventional slide handle has been completely redesigned to develop a hand-pull system that enables easy opening/closing by gripping with one hand. In addition, the cover is equipped with a scalding prevention guard to prevent scalding due to steam. Equipped with 4 selectable courses and 3 customizable programs Any of 4 courses can be selected according to the purpose of use, and 3 types of setting values can be stored for each course according to the usage conditions. The setting values (sterilizing temperature, sterilizing time, melting temperature, melting time, keep warm, exhaust temperature, exhaust rate) for each program can be easily changed by the user for easy use. 2. Sterilizing/Keep Warm After sterilizing culture media, reagents and other liquids, and cooling down naturally to a selected temp., air is expelled automatically from the exhaust valve. High temp. prevents solidifying. 3. Melting/Keep Warm To melt or keep culture media at a fixed temp. (This function is not for sterilizing but prevents solidifying). 4. Instrument Sterilizing For flasks, beakers, test tubes, other lab instruments. When completed, the exhaust valve opens and the temp. drops to 100 C. Thus, cool down period can be shortened. Suitable for equipment that can withstand sharp drops in pressure and for sterilizing waste. Sterilizing temp.: 115 C to 135 C Timer: 1 to 300 min. Exhaust temp.: 0 C to 45 C Incubation temp.: 45 C to 60 C. Melting temp.: 60 C to 114 C Timer: 0 to 300 min., 72 hrs. Incubation temp.: 45 C to 60 C Sterilizing temp.: 115 C to 135 C Timer: 1 to 300 min. Functions for user safety and cooling fan/exhaust level adjustment to reduce cooling time. Conforming to the requirements of IEC standards, when using sterilizing liquid the temperature when opening the cover is set to 65 C or less. In addition, by adding exhaust holes at several positions on the side of the product and positioning the standard-equipment cooling fan under the chamber, cooing efficiency and sterilizing efficiency are increased, so that operating time can be reduced. Furthermore, a constant open/close interval (with 5-step adjustment) for the exhaust process valve enables selection of the exhaust rate for steam inside the chamber to enable cooling in a shorter time while reducing exhaust time and preventing boiling over of sterilizing liquid. 121

125 Autoclaves MLS-3751L / MLS-3781L Thermal printer (optional) The work conditions shown on the control panel (temperature/pressure inside chamber, sterilizing course, time) can be printed out by a line thermal dot printer for record-keeping, management, and storage. Microprocessor temperature control Sterilizing temperature is controlled to within +2 C/-0 C of the set temperature in the range of 115 C to 135 C. Wire Baskets Solid Bucket Perforated Bucket Air vent control Can be set to allow automatic release after sterilizing is completed. Options Object temperature sensor Printer (with 1 roll of paper) Printer paper MLS-37SB MLS-37PR MLS-37PR-S (5-roll set) Stainless Steel Baskets and Buckets inner dims. Wire Baskets MLS-37BL ø335 x 2 MLS-37BS ø335 x 170 Solid Bucket MLS-37C30 ø330 x 300 Perforated Buckets MLS-37PB30 ø330 x 300 MLS-37PB40 ø330 x 400 (MLS-3781L only) 122

126 Specifications Model Power supply Power consumption External dimensions (W x D x H) Weight Chamber dimensions (diameter x depth) Effective chamber height including recess in lid Effective capacity Chamber material Maximum pressure Sterilisation temperature Culture media melting temperature Keep warm temperature Sterilisation timer Melting timer Keep warm timer Program timer Exhaust tank Exhaust control Safety devices Pressure vessel type Accessories included MLS-3751L MLS-3781L 230V single phase (50-60Hz) 8.7 A or above 230V single phase (50-60Hz) 17.4A or above 2kW 4kW 478 x 632 x 748 mm 478 x 632 x 965 mm 61 kg 71 kg Ø 370 x 415 mm Ø 370 x 630 mm 463 mm 688 mm 50 litres 75 litres SUS304 (Austenitic stainless steel) 0,240MPa 115 C to 135 C 60 C to 114 C 45 C to 60 C 1 to 300 minutes 1 to 300 minutes 72 hours fixed 1 week (Designation: Year, month, day, hour and minute) 2-litres polyethylene tank Exhaust valve open temperature setting Pressure safety valve, over-temperature limiter, anti-scorch limiter, door interlock, over-pressure limiter, current fuse Small-scale pressure vessel Stainless steel baskets Large: 1, small: 1 Stainless steel baskets Large: 2, small: 1 Drain hose: 1 Exhaust tank: 1, tank mounting bracket: 1 and tip-resistant metals: 2 Process operation Example: Instrument sterilisation course ( C) (Operating conditions: No load; Ambient temperature: C; Sterilizing temperature: 121 C, Sterilizing time: min.) MLS-3751L MLS-3781L MLS-3750* MLS-3780* *Our company s previous models (min.) Operating time varies depending on operating conditions. For liquid sterilisation course, the operating time will be longer than for instrument sterilisation course. Dimensions MLS-3751L MLS-3781L Unit: mm 123

127 Laboratory Autoclaves MLS-24U / MLS-30U MLS-24U LITRES MLS-30U 48 LITRES Accurate sterilisation temperature control - easy to use The importance of sterilisation is growing in the field of good laboratory practice in areas such as biotechnology and medicine. Of all sterilisation methods, the use of high pressure steam (autoclave) is the most widely used because of its efficacy, speed and reliability. This method is suitable for a wide range of applications including culture media, glass and metal implements, and waste products. SANYO laboratory autoclaves provide a safe, reliable high pressure steam sterilizing environment within a unit that is particularly easy to use. Microprocessor control ensures that the correct temperature is accurately maintained and easily operated with one-touch operation. Fail-safe functions ensure user safety and the compact design maximises use of valuable laboratory space. These reliable, energy saving autoclaves are ideal for a wide range of applications. Microprocessor control maintains accurate sterilisation temperature. A microprocessor monitors and controls the steam temperature within the chamber, ensuring that it is maintained within the range 105ºC - 126ºC. Easy to operate ergonomic design The interior of the chamber is free of protrusions such as sensors or piping joints that could interfere with the insertion or removal of items. The single rectangular handle turns easily and securely seals the chamber. The control panel is mounted at the top of the unit, making it easier to see and operate. A water outlet valve allows easy changeover of the sterilisation water. 124

128 Process operation Standby ( C) Water filling Heating Sterilisation Cooling Completion Sterilisation 121 C - 15 min. Sterilisation 126 C - 15 min (min reliable Your SANYO personal accurate Digital controls and display eliminate setting errors The digital control panel allows temperature and time settings to be entered accurately in 1ºC and 1-minute intervals. The display panel is easy to read helping to prevent errors when setting parameters. Pressing the (TEMP) and (TIMER) keys simultaneously displays the remaining sterilisation time. Safety assured with fail-safe functions 1. Dry scorch protection function Should the water level drop too low, an overheating protection circuit is triggered, a buzzer sounds and an error message appears on the display. Buzzer alert: pairs of short beeps repeated in succession. 2. Door switch A safety mechanism prevents the autoclave from operating if the door is not completely closed. A door closed lamp lets you check whether the door is closed. 3. Pressure safety valve A reliable pressure safety valve is used to prevent the pressure inside the chamber from rising above acceptable levels. 4. Thermistor error detector function If the thermistor temperature sensor goes open circuit (connection broken), the heater turns off to prevent overheating. Buzzer alert: pairs of short beeps repeated in succession. 5. Overheating protection function The digital display starts to flash if the temperature in the chamber rises more than 2ºC above the temperature setting. If it rises 3ºC or more above the setting, the relay shuts off and cuts off power to the heater. 6. Door protection function If the magnet-holder is not connected to the switch button, the high pressure lamp will flash when the temperature inside the chamber is over 99ºC. 125

129 Laboratory Autoclaves MLS-24U / MLS-30U Audible and visual alarms alert the user to end of cycle and error conditions. The unit sounds a buzzer to alert the user to any error conditions requiring attention and to the end of the sterilisation cycle so that items can be removed from the autoclave. 1. Sterilisation finished alert function A buzzer sounds to tell you when sterilisation is finished. 2. Safe to open door alert function The unit continues to monitor the temperature inside the chamber after sterilisation is finished. Once the autoclave has cooled to the point where it is safe to open the door, a buzzer sounds. 3. Safe to remove contents alert function (cycle fully complete) When the items being sterilized have cooled down to the point where it is safe to remove them, a buzzer sounds. Compact design ideal where space is limited. The body of the unit, with its built in exhaust bottle, measures a mere 380 x 490 mm (MLS-24U) and 440 x 550 mm (MLS-30U) so it will fit in the tightest spaces. Features of MLS-30U/24U. Wide variety of items can be autoclaved using 126ºC sterilisation. The pressure vessel is designed to meet the ASME safety code. In accordance with the code, these units have a lid interlock function. 126

130 dedicated precise Specifications Model Power supply Power consumption Exterior dimensions (W x D x H) Chamber dimensions Chamber material Sterilisation temperature Temperature gauge range Safety valve release pressure Pressure gauge range Timer setting range Exhaust tank Safety devices MLS-24U 230V AC (50/60Hz), 6,5 A 1,5 kw 380 x 490 x 840 mm 240 x 450 mm Stainless Steel (SUS304) MLS-30U 230V AC (50/60Hz), 8,7 A 2kW 440 x 550 x 1050 mm 300 x 670 mm Stainless Steel (SA-240 type 304) 105ºC - 126ºC Digital display 80º - 141ºC 177kPa (25psig) MPa / 0-45psi minutes 3L polyethylene Pressure safety valve Anti dry scorch thermo limiter Door switch Handle switch Current fuse Accessories Vinyl cover Stainless steel baskets x 2 Vinyl cover Stainless steel baskets x 3 Applicable standards Pressure vessel: Japanese standard/ce ASME Code/CSA/CSA-NTRL (UL)/CE Dimensions MLS-24U MLS-30U Options Special round basket, A (for MLS-24U) Dimensions: 2(ø) x 215(H)mm MLS-RBA Special round basket, B (for MLS-30U) Dimensions: 290(ø) x 215(H)mm MLS-RBB Special round basket, Half (for MLS-30U) MLS-RBH Dimensions: 290(ø) x 3(H)mm Unit: mm 127

131 Sturdy Autoclave Sterilizer SA-230FA / SA-260FA / intelligent SA-260FA 24 LITRES SA-230FA 16 LITRES Intelligent design for your professional choice The innovative and versatile autoclave, which combines compact and elegant design with high performance, reliability and safety. The Falcon Series Class S has a microprocessor controlled system, with 8 programs installed, and a special program of liquid sterilisation. Special indication signs keeps the user informed about the water level, the cycle steps and if the door is closed completely. There is also a pressure door auto-lock device which ensures the door is always closed when the chamber is under pressure. To guarantee a optimal dry results, the Falcon series offers an auto dry function. The pressure switch and a steam pressure safety valve offers a double protection. Installed eight (8) programs and special program for LIQUID sterilisation for your selection. The Super Microm Series Class B has all the features as mentioned earlier, but is even more specialized. They are standard equipped with pre- and dry vacuum function, and 24 programs are installed such as special programs for PRION sterilisation, LIQUID sterilisation, BOWIE-DICK test and PUMP test. 128

132 SA-230MA / SA-260MA SA-260FA Door lock Double protected chamber Sterilisation box SA-260MA 24 LITRES Sterilisation plate SA-230MA 16 LITRES Option Sterilisation Box Specifications Model SA-260FA SA-230FA Autofill water system Yes Yes Auto dry function Yes Yes Auto dry time can be selected: 0, 15, 30, 35, 40 min. - - External dimensions (D x W x H) 655 x 533 x 442 mm 594 x 522x 410 mm Chamber size ø 260 x 450 mm (D) ø 230 x 410 mm (D) Water capacity of the tank 40 ml 40 ml Chamber capacity 24 litres 16 litres Net weight 51 kg 48 kg Power supply 230V 50/60 Hz 230V 50/60 Hz Door Closed, Low water, Overheat display Yes Yes Power consumption 2300 W / 11 Amp W / 8 Amp. Sterilisation temp. 121ºC / 135ºC 121ºC / 135ºC Functions 121ºC / 135ºC, wrapped/unwrapped, dry/undry, liquid. When using the dry function, please open the door to get a better dry result after the exhaust step completed. Safety device Pressure safety valve Yes Yes Over temperature protection Yes Yes Electric overload protection Amp. Amp. Non Fuse Breaker x 2 Non Fuse Breaker x 2 Over pressure protection Pressure protection switch Pressure protection switch Door lock indication Yes Yes Water tank water level sensor Yes Yes Chamber water level sensor Yes Yes Pressure door auto-lock Yes Yes Supllied Accessories Sterilisation Plate set Plate x 3, Plateframe x 1, Plate holder x 1 SA-260MA SA-230MA Yes Yes - - Yes Yes 655 x 533 x 442 mm 594 x 522 x 410 mm ø 260 x 450 mm (D) ø 230 x 410 mm (D) 40 ml 40 ml 24 litres 16 litres 52 kg 49 kg 230V 50/60 Hz 230V 50/60 Hz Yes Yes 2400 W / 11 Amp W / 8 Amp. 121ºC / 135ºC 121ºC / 135ºC 121ºC / 135ºC, wrapped/unwrapped, dry/undry, liquid, PRION program, Bowie dick, Pump test Yes Yes Yes Yes Amp. Amp. Non Fuse Breaker x 2 Non Fuse Breaker x 2 Pressure protection switch Pressure protection switch Yes Yes Yes Yes Yes Yes Yes Yes Sterilisation Plate set Plate x 3, Plateframe x 1, Plate holder x 1 129

133 Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV LITRES 40 C~250 C Accurate, High-Temperature Equipment for Scientific Research SANYO has always aimed to provide research support equipment that offers complete satisfaction to its users. Inspired by the search for even higher precision and greater flexibility of control, SANYO presents the MOV Series. Microprocessor PID temperature control system guarantees an accurate temperature environment The microprocessor PID (Proportional, Integrated and Differential) temperature control system ensures accurate inside temperature. With less offset or overshoot, precise control is possible. This system provides the hightemperature environment that exactly meets experimentation requirements. The MOV Series can be widely used for basic to applied experimentation in the areas of scientific, industrial and environmental testing. Metal protection tube Inorganic dust insulator (magnesium oxide) Heating element (nickel chrome) Sheathed heater ensures durability and safety A sheathed heater is incorporated in the heater section. The heating element is wrapped in a magnesium oxide insulating material and covered with a metal protection tube. With conventional wire heating elements, gases or dust can cause corrosion, resulting in loss of heating capacity and electrical leakage. With its durability and high chemical resistance, the sheathed heater ensures safer, more stable operation without the risk of electrical leakage. 130

134 MOV-212S Your SANYO professional MOV LITRES 40 C~250 C Applications Medical Science (Drying equipment and samples) Medicines/Foods (Drying tests, Measurement of moisture levels, Heat resistance tests, Tests of durability, Drying) Agriculture/Soil Science/Water Analysis (Measurement of moisture levels, protein mass, or residual matter) Construction Industry/Building Materials (Heat resistance tests, Analysis of new materials, Drying tests) Electronics/Metallurgy/Mechanics (Aging, Heat treatment, Baking, Heat resistance tests) Chemistry/Fiber Technology/ Ceramics (Measurement of residual matter & moisture level, Heat resistance tests, Baking, Bonding/hardening/softening tests, Thermal denaturation tests). Microprocessor timer function SANYO has included a microprocessor timer function, so operated times can be set up to a maximum of 99 hours and 59 minutes. The combination of auto start and auto stop provides operating patterns suited to a wide variety of applications. The auto stop operates the timer when the heater is on, or when the set temperature has been reached. A buzzer indicates the end of timer operation. Attractive design SANYO believes that laboratory equipment should be attractive as well as functional. The MOV Series features a future-oriented design, with rounded corners, door handles that blend with the main body, and a flat control panel. Alarm and safety functions A comprehensive range of alarm and safety devices is included as standard in the MOV Series. Alarm and safety functions Automatic set temperature alarm Independent overheating protection circuit Overtemp. safety system for control section Trigger More than 10 C deviation from set temperature. Abnormal temperature increase above upper limit. Ambient temperature of main part (base) of control section exceeds 65 C. Alarm notification method and operation Lamp, LED, buzzer. While not in operation: buzzer. While in operation: lamp, LED and buzzer. Independent circuit switches off heater and fan motor. Lamp, LED, buzzer. Heater and fan motor switched off. Keylock switch Memory backup function Keylock switch on. During power failure, breaker cut or when unit is not connected to power supply Key input not possible (excl. buzzer and call key). Stores operation patterns for set temperatures/ times. 131

135 Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-112F MOV-112S 90 LITRES 40 C~0 C MOV-212F MOV-212S 150 LITRES 40 C~0 C accurate User-oriented design for easy operation The control panel has soft-touch keys and bright, green digital LED display that allows easy confirmation of temperature and remaining operation time. Other advantages of the design include a soft-latched door handle integrated with the door, an observation window for checking conditions inside the cabinet, two exhaust vents (shared with an access vent) on the top of the unit, and a stainless-steel (SUS-304) interior to guarantee durability and superior resistance to chemicals. Malfunction Monitor (Self diagnosis function) Should a malfunction occur, it is diagnosed and indications are given on the digital display. Built-in microprocessor timer guarantees accurate sterilisation time The built-in microprocessor timer (max. setting 99 hours and 59 minutes) accurately adjusts sterilisation time. A consecutive display of the inner cabinet temperature is provided for quick confirmation of the time when samples should be removed. And a buzzer sounds at the end of timer operation. In combination with auto start and auto stop, operation patterns can be set for a wide range of applications. Natural convection system (MOV-112/MOV-212) Natural convection is best for drying very small samples and fine particles which would be scattered by a fan. This system can be used for high-temperature applications up to 250 C. Forced air circulation system (MOV-112F/MOV-212F/MOV-112S/MOV-212S) Sirocco fan circulation keeps variations in inner cabinet temperature within ±4 C at 0 C. Compared with natural convection, quicker drying is possible. And SANYO s unique fan motor not only circulates hot air in the cabinet but also keeps the motor cool, improving the reliability and safety of the motor. 132

136 MOV-212S Specifications Model No. Exterior dimensions (W x D x H) Interior dimensions (W x D x H) Effective capacity Exterior finish Interior finish Insulation See-through window Shelves Air exhaust vent Heating system Temperature control system Sensor Temperature setting Timer Temperature/Timer display Heater (Sheathed heater) Interior fan Exterior fan Power source Max. power consumption Temperature range Temperature controllability Temperature uniformity Weight Alarm and safety function Electric Ovens Dry Heat Sterilizers MOV-112F MOV-212F MOV-112 MOV-212 MOV-112S MOV-212S 580 x 595 x 8 mm 730 x 645 x 870 mm 580 x 595 x 8 mm 730 x 645 x 870 mm 580 x 595 x 8 mm 730 x 645 x 870 mm 450 x 450 x 450 mm 600 x 500 x 500 mm 450 x 450 x 450 mm 600 x 500 x 500 mm 450 x 450 x 450 mm 600 x 500 x 500 mm 90 litres 150 litres 97 litres 157 litres 90 litres 150 litres Baked acrylic finish on galvanized steel Stainless-steel plate (SUS-304) Glass wool Reinforced triple glass window (t = 5mm) Stainless-steel plate, stainless-steel wire (adjustable) Two on top plate (32mm inside dia.) Forced air circulated system Natural convection system Forced air circulated system Microprocessor PID control Thermo couple Digital setting (adjustable range: ± 1 C) Auto start, Auto stop 00:00 ~ 99:59/one step. Digital LED display 1.1kW 1.2kW 1.1kW 1.3kW 1.1kW 1.2kW Sirocco fan dia. 149mm Sirocco fan dia. 149mm Propeller fan 107mm Propeller fan 107mm 2V/240V, 50/60Hz Approx. 1.1kW Approx. 1.2kW Approx. 1.1kW Approx. 1.3kW Approx. 1.1kW Approx. 1.2kW 40 C ~ 0 C 40 C ~ 250 C 40 C ~ 0 C ±1 deg. ±4 C (at 0 C) ±10 C (at 0 C) ±4 C (at 0 C) 50 kg 66 kg 47 kg 63 kg 50 kg 66kg Overcurrent breaker, alarm for automatic set temperature (set point +10 C), independent overheating protection circuit, overtemperature safety system for control section (triggered at 65 C), self diagnosis. Performance data MOV-112F / MOV-212F / MOV-112 / MOV-212 / MOV-112S / MOV-212S MOV-112 MOV-212 MOV-112F/S MOV-212F/S Dimensions MOV-112F/S MOV-212F/S 450 Unit: mm note: The size of the MOV-112/212 is 25mm deeper, due to the fact that these models use a natural convection system. 133

137 Commercial Use Air Purifying System SANYO VW-VF10BG reliable Your SANYO innovative progressive Enhanced Virus Protection The quality of the air we breathe is important for our well-being and in places where people gather, such as schools, hospitals and other public facilities, airborne germs are often present. Infectious airborne viruses can be rendered harmless from the treated air by SANYO s Electrolyzed Water Technology. Inactivates airborne viruses with the power of electrolyzed water. The Virus Washer uses an Electrolyzed Water Disinfecting Element to inactivate viruses and other airborne microbes and particles. Electrolyzed water runs over the air purification element in the Virus Washer. Indoor air is then forced to circulate through the element, inactivating airborne viruses which pass through it. Independent verification tests have shown that electrolyzed water is effective in suppressing more than 99% of viruses in the air passing through the disinfectant element in a single pass. Powerful cleaning can be used in schools, hospitals, offices, and other large spaces. To clean the air in large spaces where many people come and go, the fan speed can be set to 480m 3 /h (8m 3 /min). This makes the Virus Washer suitable for use in schools, hospitals, and other large spaces where people gather. The powerful cleaning capacity is capable of circulating the air approximately 2.7 times per hour in a school classroom (approximately 180m 3 ). How Electrolyzed Water inactivates Viruses Viral protein (spike) Destroyed spike HClO OH OH HClO Electrolyzed water HClO OH HClO Hypochlorous acid OH HClO OH HClO OH Hydroxyl radical Cell Membrane Receptor* Cell interior *Needed for the virus to infect the cell The electrolyzed water destroys the proteins (spikes) on the surface of the virus, rendering the virus inactive. 134

138 Inactivates more than 99% of airborne viruses and bacteria, and reduces pollen and dust mite allergens from treated air. Improves air hygiene. Designed for enclosed spaces up to 100m 2 (300m 3 ) such as within hospitals, offices and other public places. Humidifies dry air. Easy to install. Results of Virus Inactivation Test Airborne bacteria disinfectant test results Remaining infectious strength (%) of viruses in the collection fluid Passing once through the element inactivated 99% or more of airborne viruses Without element With air purification element Operating time (minutes) (Joint research conducted with the Gunma Prefectural Institute of Public Health and Environmental Sciences) Number of airborne bacteria (particles/100 liters) Natural decline More than 99.9% of the airborne bacteria removed after 5 minutes 10 1 Space purification system (Virus Washer with Disinfectant Element) VW-VF10BG Specifications Model Power source Exterior dimensions (W x D x H) mm Weight: Product weight kg Operating weight kg Operation: Operating modes Ambient usage temperature Water to be used Electrical characteristics: Power consumption W Current A Ventilating device: Rated airflow m 3 /min Louvre Airflow direction adjustment range Continuous operating time: Summer hours Winter hours Disinfectant element Water supply and drainage Operating noise db (A) VW-VF10BG AC V, 50-60Hz 580x 297 x (when water supply tank is full) High / Mid / Low 5 35 C Tap water (potable) Maximum Total Hardness (TH) of Tap Water: 400ppm as CaCO 3. Virus Washer Water Filters required above 100ppm TH High: 145, Mid: 78, Low: 57 High: 2.10, Mid: 1., Low: 0.88 High: 10, Mid: 5, Low: 2 Two louvres (with swing function, closing with power OFF) 0 23 (airflow direction position memory) High: 7, Mid: 12, Low: 18 High: 6, Mid: 10, Low: 15 Stationary type Water supply tank (capacity approx. 6 litres), drainage tank (capacity approx. 2 litres) High: 49, Mid: 35, Low: 29 Dimensions Specifications with high-performance micro-particle filter mounted Model Particle trapping efficiency % AFT-HVW10BG Equivalent to 65% by colorimetric assay method Rated airflow m 3 /min (equivalent to 93% by gravimetric method) High: 8, Mid: 4, Low: 2 Operating noise db (A) High: 49, Mid: 35, Low: 29 Unit: mm 135

Ultra-Low Temperature Chest Freezers

Ultra-Low Temperature Chest Freezers Ultra-Low Temperature Chest Freezers SANYO Ultra-Low Temperature Chest Freezer lineups for ultra-low temperature storage needs to support the forefront of life science researches. MDF-94AT MDF-193 MDF-116

More information

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES ULTRA LOW TEMPERATURE FREEZERS SERIES TwinGuard Models: MDF-U500VX-PE MDF-U700VX-PE MDF-DC500VX-PE MDF-DC700VX-PE Panasonic s TwinGuard -86 C freezers deliver the unsurpassed level of safety and sample

More information

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

TwinGuard ULTRA LOW TEMPERATURE FREEZERS ULTRA LOW TEMPERATURE FREEZERS TwinGuard Models: MDF-DU302VX- PE MDF-DU502VX-PE MDF-DU702VX-PE MDF-DC500VX-PE MDF-DC700VX-PE The most secure ultra-low temperature freezers for the storage of high value

More information

Refrigerated Incubators / Environmental Testing Chambers

Refrigerated Incubators / Environmental Testing Chambers Refrigerated Incubators / Environmental Testing Chambers MIR-154 MIR-254 MIR-553 MLR-351H SANYO s MIR and MLR series incubators have been recognized as exceptional units suitable for a wide range of applications.

More information

Heated and Refrigerated Incubators

Heated and Refrigerated Incubators Heated and Refrigerated Incubators MIR-162-PA MIR-262-PA MIR-154-PA MIR- 254-PA MIR-554-PA us.panasonic-healthcare.com powered by TM Heated and Refrigerated Incubators Panasonic MIR series incubators are

More information

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES -86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES TwinGuard Models: MDF-U5VXC-PA MDF-U7VXC-PA MDF-DC7VXC-PA The patented TwinGuard series delivers an unsurpassed level of temperature performance and sample protection,

More information

function creates form

function creates form Biomedical Equipment During the process of evolution, nature has developed perfect designs. Every detail is an example of perfect engineering, 1% dedicated to its task. Every form in nature has been created

More information

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192 -86ºC-Freezer PICTOGRAM [ FOR EXPL. P.3 ] Ultra-Low Temperature Chest freezers: CFC-Free Casters A wide range of ultra-low temperature freezers to suit your needs. Ideal -86ºC freezing environment by means

More information

-86ºC-Freezers. Ultra-low temperature upright freezer -86ºC MDF-U5086W MDF-U6086S MDF-U5186S MDF-U4086S MDF-U3086S MDF-U2086S MDF-U5086W

-86ºC-Freezers. Ultra-low temperature upright freezer -86ºC MDF-U5086W MDF-U6086S MDF-U5186S MDF-U4086S MDF-U3086S MDF-U2086S MDF-U5086W MDF-U586W MDF-U686S MDF-U486S MDF-U86S MDF-U86S MDF-U586W 497 LITER 19 -BOXES 144 -BOXES PICTOGRAM [ FOR EXPL. P. ] CFC-Free CPU and Touch Pad LED Digital Display Quiet, Reliable Compressor Rechargeable

More information

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A

-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A -86 C ULTRALOW TEMPERATURE FREEZERS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com NuAire Glacier -86 C Ultra-low Temperature Freezer NuAire Glacier -86 C Ultra-low

More information

Serie V.I.P. Congelatori -86 C F

Serie V.I.P. Congelatori -86 C F SANYO patented V.I.P. Vacuum Insulation Panel for high density storage Serie V.I.P. Congelatori -86 C F Integrated Ultra-Low Storage Solutions For Biosafety, Security and Performance Tre livelli di sicurezza

More information

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter by Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Technical Specifications Brouwer -86 o C Chest STORAGE SPECS UNIT -86 DFC 370-86 DFC 620-86 DFC 820 Capacity L 370 620

More information

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS ARCTIKO AIMS to be the first and best choice of partner in delivering advanced and customized cooling and freezing solutions

More information

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818) UCUF191S-86, UCUF241S-86 and UCUF281S-86 UPRIGHT ULTRACOLD FREEZERS Control and Alarm Features Manual defrost, adjustable control range from -50 C to -86 C. UL/CUL Listed. Factory preset at -80 C. Advanced

More information

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings 86 C freezers New Benchmark New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings 2 World-class service. NEW HEF Models For over 50 years, New Brunswick lab products

More information

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter Igloo More samples, less footprint Laboratory space is valuable. In comparison with the traditional freezers, Telstar

More information

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC The Industry s Safest Ultra-Low Storage Solution for High Value Biologicals The 18.3

More information

V.I.P. Series -86 C Ultra Low Freezers

V.I.P. Series -86 C Ultra Low Freezers V.I.P. Series -86 C Ultra Low Freezers MDF-U33V MDF-U52VA MDF-U53VC MDF-U73VC Ideally suited for ultra low storage solutions and long term preservation of biologics, reagents, specimens, components and

More information

V.I.P. Series -86 C Ultra Temperature Freezers. The Ideal 86 C, Preservation Environment in Capacities from 12 cu.ft. to 26 cu.ft.

V.I.P. Series -86 C Ultra Temperature Freezers. The Ideal 86 C, Preservation Environment in Capacities from 12 cu.ft. to 26 cu.ft. V.I.P. Series -86 C Ultra Temperature Freezers MDF-U32V MDF-U52VA MDF-U53VC MDF-U73VC ULTRA LOW TEMPERATURE FREEZERS (VACUUM PANEL INSULATION) The Ideal 86 C, Preservation Environment in Capacities from

More information

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work NEW! Thermo Scientific Revco PLUS -86 C Freezers Protecting Your Life s Work Your life s work. What is it worth to you? Your life s work. What is it worth to you? You spend countless lab hours developing

More information

Biomedical Freezer 37 38

Biomedical Freezer 37 38 Biomedical Freezer 37 38 Biomedical C (Upright) C (Upright) This product is design for storage of critical and temperature sensitive biological samples, medical products, and so on in institutions such

More information

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control Ultra-Low Temperature Freezers Series Microprocessor Control Basic Series Solid-State Electronic Control 2 Ultra-Low Freezers Queue Advantage ultra-low temperature freezers create stable -86 C, -50 C and

More information

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC

Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC Twin Guard Series -86 C Ultra-Low Freezer Featuring SANYO -86 Dual Cool Independent Refrigeration Systems MDF-U500VXC The Industry s Safest Ultra-Low Storage Solution for High Value Biologicals The 18.3

More information

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700 Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700 02 Ultra low temperature freezers for long-term storage at -86 C 03 LONG-TERM STORAGE OF SAMPLES Always the right design

More information

Ultra low temperature freezers. -40 C and -86 C. Green Line

Ultra low temperature freezers. -40 C and -86 C. Green Line Ultra low temperature freezers -40 C and -86 C Green Line by by Ultra low freezer series Brouwer ultra low temperature freezers are available in two temperature ranges: -40ºC and -86ºC. The standard internal

More information

-86 C Ultra-Low Freezers

-86 C Ultra-Low Freezers -86 C Ultra-Low Freezers MDF-U33V MDF-U53VA MDF-U56VC MDF-U76VC VIP Series The Industry s Most Complete Ultra-Low Storage Solution GREEN product Features: Industry leading -86 C preservation for uniformity,

More information

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers Maximizing Critical Sample Protection and Storage Innovative Features and Rewarding Benefits Features Advantage Benefit Refrigeration

More information

Protect your research

Protect your research Protect your research Advanced scientific refrigeration systems >ULT Freezers >Enzyme Freezers >Laboratory Fridges >Domestic Upright Manual Defrost Freezers >CO2 and O2 Incubators scientific pty ltd Quality

More information

Ultra-Low and Cryogenic Solution

Ultra-Low and Cryogenic Solution Ultra-Low and Cryogenic Solution VIP Series Twin Guard Series PRO Series Cryogenic Chest www.panasonic-healthcare.com/us/biomedical powered by powered by Discovery starts with a dream. A dream to know

More information

-86 C Ultra-Low Freezers

-86 C Ultra-Low Freezers -86 C Ultra-Low Freezers MDF-U5486SC PRO Series -86ºC Freezers Features: Energy-saving storage solutions for uniformity, reliability and environmentally safe operation. New Cool Safe refrigeration systems

More information

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program 12 Haier Bio-Medical Haier Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program This product is specially designed and manufactured for long time storage

More information

-86 Ultra Low Temperature Freezer

-86 Ultra Low Temperature Freezer - Ultra Low Temperature Freezer Note: If slight difference occurs between pictures and actual products, please refer to actual products. Our company reserves the right of final interpretation to this brochure

More information

ENVAIR lab CO2 Incubator

ENVAIR lab CO2 Incubator ENVAIR lab CO2 Incubator Laboratory Incubator Air-jacketed CO2 Incubator Introduction C02 Incubators are widely used in scientific research to grow and maintain cell cultures. A ENVAIR lab CO2 Incubator

More information

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results Galaxy Plus creating perfect conditions Scientists told us how they used CO 2 incubators

More information

TISSUE EMBEDDING CENTER

TISSUE EMBEDDING CENTER TISSUE EMBEDDING CENTER Tissue Embedding Center (Model No. : MW-3080-STE-004) Tissue embedding system is designed fit your needs. Each high capacity module is designed with temperature controls that can

More information

BLOOD BANK REFRIGERATOR - BR Series

BLOOD BANK REFRIGERATOR - BR Series BLOOD BANK REFRIGERATOR - BR Series TRANSFUSION SYSTEMS ISO 13485 Optimize blood care with advanced technology The most secure environment for blood products outside the human body FEATURES BLOOD BANK

More information

Introductions. Safe for cultivation

Introductions. Safe for cultivation ES cell research In vitro fertilization cell test Introductions CO2 incubators are widely used in scientific research to grow and maintain cell cultures. A Heal Force CO2 incubator provides you with unsurpassed

More information

A look into our complete product collection.

A look into our complete product collection. A look into our complete product collection. PRODUCT GROUPS: -150 C Freezers -86 C Freezers -30 C Freezers Refrigerators Refrigerator & Freezer Combo Units CO 2 Incubators Multigas Incubators Drosophila/Plant

More information

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS BUSINESS SOLUTIONS Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS SOLUTIONS FOR DEMANDING NEEDS RELIABLE. USER-FRIENDLY. ECO-FRIENDLY Medical Certifications are key to success Our Premium line

More information

Refrigerators. Upright Blood Bank. i.series Horizon Series

Refrigerators. Upright Blood Bank. i.series Horizon Series Refrigerators Upright Blood Bank Blood Bank Refrigerators Helmer has provided high-quality laboratory equipment and refrigerated products for over 30 years. Our experience and attention to detail allow

More information

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212 MOV Series Electric Ovens Dry Heat Sterilizers /2F MOV-1/2 MOV-1S/2S SANYO MOV Series Electric Ovens and Dry Heat Sterilizers Accurate, High-Temperature Equipment for the New Generation of Scientific Research.

More information

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Ultra low temperature freezers -40 C and -86 C. NEXUS Series Our experience in biomedical cold storage c For over 80 years Angelantoni has been producing a full range of freezers for the long-term preservation of biological samples used in scientific laboratories,

More information

more than M A N U FA C T U R I N G F R E E Z E R S U LT

more than M A N U FA C T U R I N G F R E E Z E R S U LT EvoSafe-series more than C E L E B R AT I N G M A N U FA C T U R I N G U LT years F R E E Z E R S Evolutionary Safe Ultra-Low Temperature freezers -86 0 C A full range of Ultra-Low Temperature freezers,

More information

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers Laboratory Pharmacy Blood Bank Upright Refrigerators and Freezers 2 Healthcare's most advanced refrigerators and freezers Follett medical grade refrigerators and freezers are engineered to provide the

More information

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers Maximizing Critical Sample Protection and Storage Innovative Features and Rewarding Benefits Features Advantage Benefit Refrigeration

More information

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1 New ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1 With natural refrigerants Panasonic Healthcare s VIP ECO delivers more energy efficient

More information

Setting the Benchmark

Setting the Benchmark Ultra-Low Temperature Freezers Setting the Benchmark New Brunswick freezers set the standard for superior quality, performance and energy efficiency Eppendorf Family of New Brunswick Ultra-Low Temperature

More information

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage Part of Thermo Fisher Scientific Safeguarding your precious samples Researchers worldwide protect more than two billion

More information

ULTRA.GUARD ultra low temperature freezer

ULTRA.GUARD ultra low temperature freezer UF V series 700 Ultra low temperature freezers ULTRA.GUARD ultra low temperature freezer The new BINDER ULTRA.GUARD ultra low temperature freezer ensures safe long-term storage of samples at -86 C. This

More information

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS ULTRA-LOW TEMPERATURE FREEZERS A full range of Ultra-Low Temperature freezers (-86 C), vertical as well as horizontal, in capacities from 120 up to and

More information

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32 Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect

More information

BLOOD PRODUCT STORAGE.

BLOOD PRODUCT STORAGE. BLOOD PRODUCT STORAGE 082010 www.labcold.com Welcome to the Labcold Blood Product Storage brochure incorporating our new range of platelet incubators and agitators. Here at Labcold, we pride ourselves

More information

Advance Blood Storage system from Meditech

Advance Blood Storage system from Meditech Advance Blood Storage system from Meditech Vertical Blood Bank Refrigerator Double Door Vertical Blood Bank Refrigerator Horizontal Blood Bank Refrigerator Solar Blood Bank Refrigerator 1 Advance Blood

More information

REVCO MECHANICAL CRYOGENIC FREEZER

REVCO MECHANICAL CRYOGENIC FREEZER REVCO MECHANICAL CRYOGENIC FREEZER OVERVIEW The Mechanical Cryogenic Freezers is available. As part of the product release in 2011, we have added the CE mark and restructured our price positioning to better

More information

Cell Culture CO2 Incubators

Cell Culture CO2 Incubators Cell Culture CO2 Incubators MCO-19AIC(UV)/19AIC The industry s most complete cell culture solution for highly regulated applications or conventional incubation. MCO-19AIC EU only 0123 The MCO-19AIC CO2

More information

Ultra-Low and Cryogenic Solutions

Ultra-Low and Cryogenic Solutions Ultra-Low and Cryogenic Solutions VIP Series Twin Guard Series PRO Series Cryogenic Chest us.panasonic-healthcare.com powered by powered by Discovery starts with a dream. A dream to know who we are. A

More information

Protection, safety, reliability. And more.

Protection, safety, reliability. And more. Blowing in Faster. Protection, safety, reliability. And more. ULTRA -LOW F REEZER Ultrafreezers upright and chest S Ultra-low freezers upright and chest R 7 DIFFERENT SIZE MODELS WITH WIDE CHOICE OF INTERNAL

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series Blood bank refrigerators and freezers & Mini - Platinum & Iridium - Plasmafrost Series ANGELANTONI LIFE SCIENCE propose a wide range of blood bank equipment for blood products storage as well for shock

More information

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

Freezers. Upright Laboratory & Plasma. i.series Horizon Series Freezers Upright Laboratory & Plasma i.series Laboratory & Plasma Freezers Helmer has provided high-quality laboratory equipment and refrigerated products for over 35 years. Our experience and attention

More information

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage Part of Thermo Fisher Scientific Safeguarding your precious samples Researchers worldwide protect more than two billion

More information

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series Upright Freezers Laboratory Plasma TrueBlue. Reliability & Support Horizon Series Medical-grade freezers designed specifically for healthcare and life science applications. Helmer Scientific high-performance

More information

ULTRA LOW TEMPERATURE FREEZERS

ULTRA LOW TEMPERATURE FREEZERS ULTRA LOW TEMPERATURE FREEZERS Models: MDFDU52VHPE MDFDU72VHPE MDFUVPE MDFU55VPE MDFDUVPE MDFC8V1PE PHCbi s VIP Ultra Low Temperature Freezers represent the industry s most complete combination of refrigeration

More information

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options Laboratory Refrigerators & Freezers General Purpose Laboratory Refrigerators. Pharmacy Refrigerators. General Purpose Laboratory Freezers. Selection Guide General Purpose Laboratory Refrigerators Pharmacy

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the Radiant Warm Wall Compact Incubator Reduced Oxygen Incubator Automatic Water-Jacketed Incubator, stacked For more than 45 years, Lab-Line has been on the cutting edge of incubator development. Not only

More information

Peachtree City. Griffin

Peachtree City. Griffin Item #40097 4/15/2015 1 Hoshizaki America, Inc., the world s largest manufacturer and marketer of foodservice equipment is committed to you, our customer. Plain and simple we strive to be the best best

More information

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity Environmental Chambers 2-Door & 3-Door Extra Large Capacity product line overview environmental chambers designed for a wide range of applications Caron s extra large capacity Environmental Test Chambers

More information

Platelet bags constant shaking for long periods of time.

Platelet bags constant shaking for long periods of time. Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET

More information

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Upright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Upright Refrigerators Blood Bank TrueBlue. Reliability & Support Medical-grade refrigerators designed specifically for blood bank applications. Helmer high-performance blood bank refrigerators are a result

More information

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION SCANDINAVIAN DESIGN AND ULTIMATE PERFORMANCE TECHNOLOGY Arctiko

More information

HG DI

HG DI Sample Preparations 1. Leica CM1950 Cryostat 2. Hirayama HV-85 Autoclave 3. Hirayama HG-80 Autoclave 4. Freeze Dryer 5. Vacuum Oven 6. Sputtering Machine 7. Ultracentrifuge 8. Deep Freezer 9. DI & Ultra

More information

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Ultra low temperature freezers -40 C and -86 C. NEXUS Series Our experience in biomedical cold storage c For over 80 years Angelantoni has been producing a full range of freezers for the long-term preservation of biological samples used in scientific laboratories,

More information

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM LABORATORY FREE ZERS LABORATORY FREEZERS -30 O C i.series TM Horizon Series TM introduction LABORATORY FREEZERS -30 O C helmer laboratory freezers provide the following benefits: Programmable Defrost Times

More information

Multi-Lab REFRIGERATORS Frigidere medicale

Multi-Lab REFRIGERATORS Frigidere medicale REFRIGERATORS REFRIGERATORS 2 finishings available, epoxy coated steel white colour or stainless steel (according to the model) high insulation thickness from 40 to 75 mm (according to the model) (1) rounded

More information

Laboratory & Pharmacy Refrigerators

Laboratory & Pharmacy Refrigerators Innovation can be beautiful. Laboratory & Pharmacy Refrigerators Distinctly Laboratory & Pharmacy Refrigerators Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment

More information

Freezers. Laboratory & Plasma. i.series Horizon Series

Freezers. Laboratory & Plasma. i.series Horizon Series Freezers Laboratory & Plasma Laboratory & Plasma Freezers Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment and refrigerated products for over 30 years. Our experience

More information

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators safe easy efficient Part of Thermo Fisher Scientific Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample

More information

Service Manual Biomedical freezer

Service Manual Biomedical freezer Service Manual Biomedical freezer SANYO Electric Biomedical Co., Ltd. MDF-U333 MDF-U537 MDF-U537D MDF-U537 SM7210139 Effective models This service manual is effective following models. Model name Model

More information

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers Thermo Scientific Revco UxF -80C Series Upright ULT Freezers PART 1 GENERAL 1.1 DESIGN AND PERFORMANCE CRITERIA A. Ultra Low Temperature Freezer manufactured to operate in a temperature range of -50C to

More information

REFRIGERATOR M E D I C A L.

REFRIGERATOR M E D I C A L. M E D I C A L REFRIGERATOR NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. LRM-100 SERIES Labocon Medical Refrigerator LRM-100 Series

More information

VWR Laboratory Refrigerators and Freezers

VWR Laboratory Refrigerators and Freezers VWR Laboratory Refrigerators and Freezers 01. VERSATILE STORAGE OPTIONS DESIGNED FOR YOUR NEEDS 02. SUPERIOR UNIFORMITY AND RECOVERY AFTER DOOR OPENINGS 03. OUTSTANDING TECHNICAL SERVICE Going green. What

More information

MEDICAL DEVICES. Blood bank refrigerators and freezers

MEDICAL DEVICES. Blood bank refrigerators and freezers MEDICAL DEVICES Blood bank refrigerators and freezers ANGELANTONI LIFE SCIENCE offers a wide range of blood bank refrigerators, rapid freezers for plasma and freezers to satisfy the requests of small,

More information

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful. Innovation can be beautiful. Freezers Laboratory & Plasma Distinctly Freezers Laboratory & Plasma Precisely executed. Sharply designed. Helmer has provided high-quality laboratory equipment and refrigerated

More information

Infinity 19VS. Air Conditioner with Variable-Speed Technology. Variable-Speed, High-Efficiency Air Conditioner with up to 19.

Infinity 19VS. Air Conditioner with Variable-Speed Technology. Variable-Speed, High-Efficiency Air Conditioner with up to 19. Infinity 19VS Air Conditioner with Variable-Speed Technology Variable-Speed, High-Efficiency Air Conditioner with up to 19.0 SEER Innovation and the Environment Leaders in Technology Over 100 years ago,

More information

EVOSAFE TM -SERIES ULTRA-LOW TEMPERATURE FREEZERS

EVOSAFE TM -SERIES ULTRA-LOW TEMPERATURE FREEZERS EVOSAFE TM -SERIES ULTRA-LOW TEMPERATURE FREEZERS GREEN ULTRA-LOW TEMPERATURE FREEZERS A green range of Ultra-Low Temperature freezers (-86 C) in capacities of the 475 and 720 model. The EvoSafe-versions

More information

Freeze Dry Systems and Accessories

Freeze Dry Systems and Accessories Freeze Dry Systems and Accessories FreeZone Freeze Dry Systems AN OVERVIEW Table of Contents: Overview...1 Selection Guide...4 FreeZone Freeze Dry Systems 1 Liter Benchtop...6 2.5 Liter Benchtop...8 2.5

More information

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.

More information

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA Operating Instructions High Performance Refrigerator PR-L2466W- PA PR-L2466W-PA Please read these instructions carefully before using this product, and save this manual for future use. See page 11 for

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY. Medical Refrigeration

SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY. Medical Refrigeration SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY Medical Refrigeration Medical Refrigeration Special purpose refrigerators and deep freezers, storage and transport systems for Laboratory, Medicine,

More information

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER Overview

More information

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series

Pass-Thru Refrigerators. Pharmacy & Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series Pass-Thru Refrigerators Pharmacy & Blood Bank TrueBlue. Reliability & Support i.series Horizon Series Pass-Thru Refrigerators designed specifically for healthcare and life science applications Helmer Scientific

More information

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax erators / blood bank refrigerators / combined refrigerator-freezers / laboratory freezers /laboratory and pharmacy refrigerators Fri.med. Srl Via Riva, 26/19 14021 Buttigliera d Asti (AT) Italy Tel. +39

More information

Laboratory refrigerators and freezers

Laboratory refrigerators and freezers Laboratory refrigerators and freezers laboratory refrigerators (+1 / +8 ºC) laboratory freezers (-18 / -22 ºC) plasma freezers (-30 / -35ºC) blood bank refrigerators (+4 ºC) combination fridge / freezer

More information

laboratory & sterilization technology

laboratory & sterilization technology laboratory & sterilization technology BM SERIES Circulated Water Baths Designed for many general and special applications in microbiology, research and industrial laboratories Powerful circulation by means

More information

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs VWR LABORATORY REFRIGERATORS AND FREEZERS Versatile Storage Options Designed for Your Needs Going Green. What does it mean? The Advantages of Hydrocarbon Refrigerants 45-60% DECREASE IN REFRIGERANT CHARGE

More information

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Plasma Freezer with air circulation TC 516 acc. to DIN 58375 These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm

More information

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems A Safe, Stable Environment for Culturing Cells Ultra-reliable Queue water-jacketed CO 2 incubators are carefully engineered to provide an optimal, stable growing environment for cultures. Easy Set-Up Control

More information

ENVAIR lab CO2 Tri-Gas Incubator

ENVAIR lab CO2 Tri-Gas Incubator ENVAIR lab CO2 Tri-Gas Incubator Laboratory Incubator ENVAIR lab CO2 Tri-Gas Incubator Introduction ENVAIR lab Tri-Gas Incubator, providing precise temperature, C02, 02 control as well as high humidity,

More information