1 anti-condensation valve

2 Dimensions B C B Function The ltecnic anti-condensation valve connects between a biomass burning boiler and a direct or indirect heating system or domestic hot water system. It automatically controls the return temperature to the boiler to avoid condensation, by means of an integral thermostatic sensor. Keeping the boiler at a high temperature prevents condensation forming from the water vapour contained in the flue gases. It can be used on central biomass boilers or residential biomass burners such as fireplace heating systems and solid fuel stoves and cookers The anti-condensation valve gives the boiler a longer life and ensures greater efficiency. Design ulti-functional Body The compact brass single body casting houses the thermostatic sensor and temperature gauge pockets enables immediate installation of the unit, either on the right or left of the biomass boiler, respecting the flow directions as shown. The brass body prevents the formation of ferrous residues in the system, thereby helping to prolong the life of the boiler. nti-condensation valve nti-condensation valve incorporates a thermostatic sensor to control the temperature of water returning to the boiler, preventing the formation of condensation. The sensor has been specifically designed to be removed from the valve body for maintenance, re-setting or replacement if necessary. Pockets for Temperature Gauges The body of the anti-condensation valve in sizes DN25 (1 ) and DN32 (1¼ ) have pockets for temperature gauges on the front and rear sides. The pockets allow the installation of suitable temperatures gauges for measuring the three water temperatures and re-setting the thermostat if required. Code DN B C D E F kg R¾ R R R1¼ Code 6 th Digit D E F Setting 45 C 55 C 60 C 70 C Technical Specification Component aterial Specification Body: DN20 Brass BS EN CW617N DN25 & DN32 Brass BS EN 1982 CB753S Cap: Brass BS EN CW614N Obturator: PSU Polymer Spring: Stainless steel Swing check valve: PPS Polymer Sealing elements: EPD Union sealing washers: Non-asbestos fibre Wax thermostatic sensor Performance edium: water glycol solution ax. glycol percentage: 50% ax. working pressure: 10 bar ax. operating temperature: 5 C to 100 C Connections Pipe connections: nti-condensation valve Setting temperature: Setting accuracy: Bypass complete closing temperature: male taper with union BS EN C, 55 C, 60 C & 70 C ±2 C + 10 C

3 Components The Wooden biomass and condensation build-up Flow bypass Wooden solid fuel contains a variable moisture percentage depending on the type (logs, pellets, woodchips etc.) and seasoning. Water vapour is released during the solid fuel drying phase inside the combustion chamber. 5 7 The presence of cold zones in the boiler or flue gas chimney can lower the temperature of the flue gas down to the dew point, causing condensation to occur. Return to boiler System return Water vapour condenses onto the boiler surfaces, together with soot and part of the unburnt hydrocarbons contained in the flue gas, producing deposits and tar. These substances stick to the walls of the boiler, covering most of the inner surfaces. In addition to being dangerous due to its flammability, tar is damaging to the integrity of the boiler and limits the efficiency of the flue gas-system water exchanger. 1 nti- condensation thermostatic sensor 2 Obturator 3 Spring 4 Cap 5 Valve body 6 Temperature gauge pocket Kv Values and Flowrates 4 8 By keeping the boiler walls at the highest possible temperature, the anti-condensation recirculation and unit limits the formation of these substances, thereby increasing the combustion efficiency, controlling the emissions into the environment and prolonging the life of the boiler. Flue gas and emission control SF DN20 DN25 DN32 50 pressure loss - kpa flowrate - l/m ccumulation of ash and residues Primary and secondary air: Combustion efficiency SR NTI-CONDENSTION VLVE Zone ofcondensation forming: Deposits and tar Corrosion Reduction inheat exchanger efficiency Flammability Size DN20 DN20 DN25 DN32 Connection ¾ 1 1 1¼ Kv m 3 /h

4 Operating Principle The thermostat (1), which is completely immersed in the medium, controls the obturator (2) that regulates the flow through the bypass port (7) and back towards boiler. s the boiler starts up from cold the anti-condensation valve re-circulates the water so that it brings the boiler up to temperature as quickly as possible. Operating Principle Continued > +10 C SYSTE LODING by-pass closed > > +10 C, = SYSTE STRTUPTRNSIENT system returnclosed, = = ixed water temperature returning to boiler = Return water temperature from storage cylinder = Flow temperature = nti-condensation set temperature When the flow temperature exceeds the set temperature of the anti-condensation valve, the units cold port (8) starts to open to produce mixed water, in this phase the system loading begins. > STRT OF SYSTE LODING >, <, = Schematic Symbols When the return temperature to the boiler is greater than the set temperature of the anti-condensation valve by 10 C, the bypass port (7) closes and water returns to the boiler at the same temperature as the water returning from the storage cylinder. > +10 C SYSTE LODING > > +10 C, = Deaerator Dirt separator Pump Shut-off valve Expansion vessel Check valve otorised mixing valve Pressure reducing valve Filling unit Backflow preventer Safety reliefvalve Dirt separator for vertical pipes Deaerator for vertical pipes Y-strainer

5 Typical pplications Biomass Boiler with Calorifier for Indirect Heating Biomass Boiler with Direct Heating and Calorifier E & O.E ltecnic Ltd ustang Drive, Stafford, Staffordshire ST16 1GW T: +44 (0) E: sales@altecnic.co.uk Registered in England No: altecnic.co.uk L

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

281 Series. ThermoBloc boiler protection recirculation and distribution unit.   Installation, commissioning and servicing instructions www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

DISCALDIRT deaerator-dirt separator

DISCALDIRT deaerator-dirt separator DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+ INSTALLATION AND OPERATING INSTRUCTIONS Ariterm 60+ CONTENTS General.... 2 Installation.... 4-5 Installation of temperature limit valve... 6 Measurements and connections... 7 Technical specifications and

More information

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION woody art.v13 woody art.v14 Description Barberi thermostatic mixing valves woody are devices with side mixed water and are used to set the fluid

More information

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00 Ca 6s and BCa 6s 33-64 kw INSTALLATION AND OPERATING INSTRUCTIONS Page 1 CONTENTS: General specification Dimensions for Ca6s and BCa6s boilers. Boiler room clearance requirements Boiler block assembly

More information

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM S Y S T E M S THE SOURCE OF SUPERIOR SYSTEMS The new Sirrus Radiant wall hung boiler from Sirrus Systems offers good looks, comprehensive safety features and

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

function Adjustable thee-way thermostatic mixing valve... connections 1/2, 3/4, 1 NPT male union and sweat union mixcal adjustable three-way thermostatic mixing valve series CCREITE ISO 9 FM ISO 9 No. CLEFFI / N Replaces / N LOW LE function The Caleffi MixCal three-way thermostatic mixing valve is used in systems

More information

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Adjustable three-way thermostatic mixing valve... connections ½, ¾, 1 NPT male union and sweat union and ¾ press MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing

More information

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw Superior A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler Outputs 120, 160, 200, 240, 280 kw 1 The Superior is a, pre-assembled floor standing, gas fired high efficiency

More information

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit Multi-function compact unit for temperature control, thermal disinfection and distribution for hydraulic and domestic water system 6005 series ACEDITED ISO 9001 FM 21654 01160/17GB replaces dp 01160/08GB

More information

geothermal march 2011

geothermal march 2011 geothermal march 2011 General information Office hours: Monday to Friday 8.30am - 5.00pm. Prices: Prices are exclusive of VAT, and are subject to change without notice. All prices displayed are recognised

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Euron Compact Wall Mounted as Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS Compact, Efficient & Easy to Install & Maintain The Euron range of wall mounted gas fired condensing boilers

More information

SATK 30 heat interface unit

SATK 30 heat interface unit heat interface unit L nt In partnership with: n imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous

More information

100% IRISH...make yours a Brightfire.

100% IRISH...make yours a Brightfire. 100% IRISH...make yours a Brightfire. - Manufactured in Wexford Eliminates drafts up the chimney Low Fuel Consumption Environmentally Friendly Over 50 years of experience 17kw Boiler Inset Our 17kw inset

More information

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL STREBEL GENEVA CE ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL INDEX TABLE 1 TECHNICAL DATA SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 SECTION

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information

Cast Iron Boilers. G Series ( kW)

Cast Iron Boilers. G Series ( kW) Cast Iron Boilers G Series (320-1017kW) Mikrotherm G Series Cast Iron Boilers The Mikrotherm G Series of cast iron sectional boilers offer all the advantages of cast iron durability and longevity coupled

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo INSTALLATION, OPERATION AND MAINTENANCE Ariterm Vedo CONTENTS General...3 Installation...4-5 Laddomat 21 Connection diagram...6 Temperature control valve...7 About burning wood...8 Operation...9-11 Service

More information

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 0, 6, 5, 4 kw CLASS IN EN 0/5 Innovation with meaning BioClass NG IN EN 0/5 CLASS DOMUSA has managed

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING INSTALLATION AND SERVICING LOGIC HIU (Heat Interface Unit) Indirect 75 Indirect 50 Direct MT Direct HT When replacing any part on this appliance, use only spare parts that you can be assured conform to

More information

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas Varde Shape Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas These instructions for fitting and operating the Smoke Control kit must be read in conjunction

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

Wood Boiler Plumbing Schematics

Wood Boiler Plumbing Schematics Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5

More information

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB ISL deaerator-dirt separator ISL 46-461 series RI ISO 9001 M 2164 LI 01123/17 replaces dp 01123/14 unction eaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA Thermostatic mixing valves, low-lead, high-flow 5 series CCREDITED ISO 9 FM 5 ISO 9 No. CLEFFI 5/ N Replaces 5/5 N Function The thermostatic mixing valve is used in systems producing domestic hot water

More information

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT

FireFlexmaster. A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee. 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT FireFlexmaster A Multi Fuel Flexible Chimney Liner 10 year Manufacturer Guarantee 172 Ferry Lane, Stanley Wakefield, West Yorkshire, WF3 4LT FireFlexmaster Flexible Chimney Liner Introduction A twin skin

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS CONTENTS 2 6 7 8 9 10-12 16 17 18 18 19 2 GENERAL TRANSPORTATION, STORAGE AND OPENING THE PACKAGE Receiving the goods - Storage Opening the package 3 INSTALLATION

More information

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics Multi Energy Boilers Duo 1 & 2 Triplex 0 & 3000 Biotriplex Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics Jaspi Multi Energy Jaspi has been developing and manufacturing highlong

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing

More information

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH TABLE OF CONTENTS General Safety Information Page 2 Chimney and Flue Information Page 3 Installing the Appliance Page 4 Flue Draught Page 5 Chimney

More information

Product overview. the optimum components for every application

Product overview. the optimum components for every application For further information, please contact Distributor : Energy Technology Co., Ltd. 46 Soi On-Nuch 9, Sukhumvit Rd., Suanluang, Bangkok 020 Tel : (66) 0-272-860 Fax : (66) 0-272-869 E-mail : sales@energytechnology.co.th

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary... 5.5.1 General... 13 5.6 CD/30 (Oil Condensing Boiler Installation Assessment Form)... 15 5.6.1 General... 15 5.7 Technician Stationary... 18 5.7.1 CD/40 Energy Efficiency Checklist... 18 5.8 Work Notification

More information

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas Varde Aura Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas These instructions for fitting and operating the Smoke Control kit must be read in conjunction

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS 6.1 Types of Heating Systems 6.2 Heating Energy Sources 6.3 Furnaces and Air Heaters 6.4 Boilers 6.5 District Heating 6.6 Selection of Medium- Steam

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2 TABLE OF CONTENTS SECTION TITLE PAGE 1. SITE PREPARATION AND INSTALLATION Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2 Installation. 3 Water supply and return.. 3 Pressure/relief

More information

Installation and Servicing Instructions. Alpha FlowSmart

Installation and Servicing Instructions. Alpha FlowSmart Installation and Servicing Instructions Alpha FlowSmart Hot Water System incorporating an Alpha InTec 30/40GS Condensing Combination Boiler with Integrated Flue Gas Heat Recovery Device and wall mounted

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com HybridSeries WOOD & Combination FUEL Furnaces Continental s Hybrid Multi Fuel Combination Furnaces are extremely clean burning

More information

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application GESTRA Product Overview The optimum components for every application For further information, please contact Distributor : Energy Technology Co., Ltd. 436 Soi On-Nuch 39, Sukhumvit Rd., Suanluang, Bangkok

More information

MULBERRY STOVES. cast a warm eye on life

MULBERRY STOVES. cast a warm eye on life MULBERRY STOVES cast a warm eye on life 1 2 MULBERRY STOVES MULBERRY STOVES At Mulberry Stoves we have assembled a team of dedicated and experienced people who are determined to provide products that represent

More information

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com Hybrid Series Innovative Heating Solutions continentalheatingandcooling.com Hybrid 100 For heating requirements up to 1400 sq. ft. the Hybrid100 is up to the task. It can be connected to a new or existing

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly

More information

High quality boiler stoves and fireplace inserts

High quality boiler stoves and fireplace inserts High quality boiler stoves and fireplace inserts Aquaflam boiler stoves and fireplace inserts + Combustion chamber and water jacket made from 6mm steel sheet + + + damper to regulate chimney draft cooling

More information

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application GESTRA Product Overview The optimum components for every application Steam Traps Non-Return-Valves BK Range Steam traps with bimetallic regulator up to PN 630/Class 2500. BK steam traps are suited to the

More information

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW. boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 00 to 0kW. DHW output to,00 litres per hour. Where quality and reliability cannot be compromised, select the

More information

FOR INSTALLING AND USING

FOR INSTALLING AND USING FOR INSTALLING AND USING Description and function The Solarmix thermostatic mixing valve is designed to reduce the water temperature to a safer level. Unlike the under basin, or bath/shower type valves

More information

BIOMASS BOILER DUAL THERM

BIOMASS BOILER DUAL THERM DUAL THERM PELLET/ WOOD BOILER AUTOMATIC FUEL SWAP BACK UP PROTECTION SYSTEM INTEGRATED IN BOILER HEAT EXCHANGER PELLET HOPPER INCLUDED HEAT EXCHANGER AND BURNER AUTOMATIC CLEANING SYSTEM AUTOMATIC LOG

More information

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler THE MUCH WENLOCK Installation Instructions for Freestanding Much Wenlock Stove with Boiler Consumer Protection Act 1987 As manufacturers and suppliers of cooking and heating products, in compliance with

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

Installation, operation and care Firewood boiler Vedolux 40 UB

Installation, operation and care Firewood boiler Vedolux 40 UB Installation, operation and care Firewood boiler Vedolux 40 UB 2008-09-23 Ver 2 Replaces: 05-11 VEDOLUX 40 UB Notes 0809 To be completed when the Vedolux 40 UB is installed Serial number:... Installation

More information

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS 3.18.6 Independent Control of Two Space and One Water Heating Circulation Zones in a Fully Pumped System with Three Motorised Valves... 64 3.19 Non Domestic Systems and Processes... 64 SECTION 4 FUEL CONSERVATION

More information

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment Max-3 plus Steel Shell Boiler Responsibility for energy and environment Output range 420 to 2700 kw Now with new TopTronic E control 1 Why choose Max-3 plus? The Hoval Max-3 plus boiler delivers market-leading

More information

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A Remeha Fuel oil/gas boilers EN Installation and Service Manual 300016859-001-A 63115 Declaration of conformity The appliance complies with the standard model described in declaration of compliance. It

More information

FLUIDIZED BED BOILERS

FLUIDIZED BED BOILERS FLUIDIZED BED BOILERS Proven technology for burning fuels on solid grate with a fountain fluidized layer; The possibility of burning a wide variety of solid fuels - with large heated value range coal,

More information

HIGHLANDER Wood and Multi-fuel Stoves

HIGHLANDER Wood and Multi-fuel Stoves Highlander 10 with central heating boiler HIGHLANDER Wood and Multi-fuel Stoves APPROVED HETAS APPROVED Highlander Stoves are manufactured in Great Britain DUNSLEY HIGHLANDER-3 The Highlander-3 has been

More information

Stored Water District Heating Interface Units. Heat Interface Units

Stored Water District Heating Interface Units. Heat Interface Units Stored Water District Heating Interface Units Heat Interface Units Why choose Elson Elson are a Heatrae Sadia company, the UK s leading manufacturer of hot water solutions utilising thermal store technology

More information

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw 90 kw Clyde Alkon 90 LP Gas Floor standing condensing boilers Natural Gas 90 kw Contents General information Dimensions and Data Installation requirements Boiler wiring diagram Hydraulic systems Page Fully

More information

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet: PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL Operation and Maintenance THERMAL INTEGRATION LTD. Tel: 0845 2411441 Internet: www.heatweb.com Introduction The District Pandora Heat Bank provides hot

More information

Table 1: Hot water energy requirements

Table 1: Hot water energy requirements Table 1: Hot water energy requirements Floor area TFA (m 2 ) (a) Hot water usage V d (litres/day) (b) Energy content of water used (kwh/year) (c) Distribution loss (kwh/year) 30 63 1146 202 40 71 1293

More information

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of

More information

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095 Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095 Before commencing with the installation it is important that these instructions are read and fully understood. The DOVRE 700CBW is

More information

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating Providing sustainable energy solutions worldwide CTC heating boilers modern technology, efficient heating Biomass heating Boilers Biomass the domestic heating of the future When CTC launched its first

More information

VAILLANT SPARE PART CATALOGUE

VAILLANT SPARE PART CATALOGUE VAILLANT SPARE PART CATALOGUE Vaillant unvented indirect hot water cylinder VANTAGE VIHC120 VANTAGE 120 VANTAGE 150, 200 Vaillant gas fired storage water heater VGH 130/1, 160/1, 190/1 VGH 130/2, 160/2,

More information

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4. CASE STUDIES OF STEAM SYSTEM AUDIT IN SOME PLANTS By K.K.Parthiban, Venus Energy Audit System Introduction This article outlines the outcome of auditing of steam system conducted in process Industries.

More information

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw Subject to modification Contents 1. Important Information 4 1.1. Documentation 4 1.2. Guarantee

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS FOR VENT-FREE OR VENTED INSTALLATIONS LOG SET FOR UNVENTED GAS LOG HEATER OR VENTED DECORATIVE APPLIANCE MODELS TO20 / TO24 / TO30 (TEXAS OAK) This appliance may

More information

charnwood I S L A N D Operating & Installation Instructions

charnwood I S L A N D Operating & Installation Instructions Operating & Installation Instructions C O N T E N T S OPERATING INSTRUCTIONS Fuel Door Operation Multi Grate Lighting Controlling The Fire Riddling Refuelling Ash Clearance Overnight Burning Special Point

More information

CHARNWOOD COUNTRY 6 FT

CHARNWOOD COUNTRY 6 FT CHARNWOOD COUNTRY 6 FT Operating and Installation Instructions Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788 Internet: www.charnwood.com E-Mail: charnwood@ajwells.co.uk

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

gas condensing combi boiler

gas condensing combi boiler Wall mounted gas condensing combi boiler Engineered with innovative condensing technology to provide efficient and reliable heating and hot water Energy efficiency heating and hot water 1 Daikin in-house

More information

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0) User Manual PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) 161 621 5960 Fax +44. (0) 161 621 5966 info@atlantic2000.co.uk www.atlanticboilers.com 1 CONTENTS CONTROL STRATEGY GENERAL RULES.. P3 Variable temperature...

More information

WGO, WTGO and SGO-W. Maintenance and Service Guide. eference, ence, leave this manual with other boiler instructions. For future e refer

WGO, WTGO and SGO-W. Maintenance and Service Guide. eference, ence, leave this manual with other boiler instructions. For future e refer WGO, WGO and SGO-W Series 3 Oil-Fired Water Boilers Maintenance and Service Guide For future e refer eference, ence, leave this manual with other boiler instructions in the envelope provided with the boiler.

More information

Aquaflam Wood boiler stoves and fireplace inserts

Aquaflam Wood boiler stoves and fireplace inserts www.hsflamingo.com Aquaflam Wood boiler stoves and fireplace inserts AQUAFLAM wood boiler stoves and fireplace inserts from the HS Flamingo workshop have many above-standard features. These innovative

More information

Combustion hot flew gases passing chamber

Combustion hot flew gases passing chamber Disposal of Solid Municipal, Gram Panchayat, Domestic and Hospital Biomass Waste Through use of Incinerator, And Energy for Heating Water Introduction :- In present condition solid waste management is

More information

Fire Chief Wood/Coal Burning Furnaces

Fire Chief Wood/Coal Burning Furnaces Distributed by: BEST MATERIALS LLC Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 www.bestmaterials.com Email: Sales@BestMaterials.com Fire Chief Wood/Coal Burning Furnaces Indoor FC300F FC450 FC500E

More information

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

HYBRID SERIES FURNACES. napoleonheatingandcooling.com HYBRID SERIES FURNACES napoleonheatingandcooling.com THINK DIFFERENT. THINK NAPOLEON. Napoleon s Hybrid Series furnaces boast clean energy with sleek hybrid fuel designs. Hybrid furnaces switch from wood

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,

More information