A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091
|
|
- Christopher York
- 5 years ago
- Views:
Transcription
1 A Series ISO-9 orizontal Multistage Centrifugal Pumps AC/AI, ABI/ABS z APEC Pump ENTERPRISE CORP. 3F.,No.39,Sec. Mingzhi Rd., Taishan Dist.,New Taipei City 3,Taiwan. Tel : Fax: Vol. PIA-9
2 Index orizontal Multistage Centrifugal Pumps AC/AI, ABI/ABS (Z) Index/Type Key AC/AI General Data- AC/I AC/I AC - AC - Dimensions & Weights AC, - AI, - AC - AC ABI/ABS General Data- ABI/S ABI/S ABI/S ABI/S Dimensions & Weights ABI/S, - ABI/S, - Installation Operating Manual Nameplate Type Key AC - Pumps & Pumps Pump Type : orizontal Pump material C : Cast iron (Discharge & Suction) I : Stainless steel 3 BI : Stainless steel 3 BS : Stainless Steel 3 Stages times : stages 3: 3 stages : stages : stages : stages (The stages are not applicable to,) Delivery (m³ /h) : m³ /h : m³ /h : m³ /h : m³ /h APEC PUMP ENTERPRISE CORP.
3 AC AI Z (M) 7 Performance Range z 3rpm Feature: Reliability/Compact Form/Wide Range igh Efficiency / Easy Maintenance 3 Application: Domestic/ Light industry and farming Pressure boosting/air-conditioning systems Cooling systems or cooling machine AC/ AC/ Q (L / M) Q (M³/) AC z AI z Pump The AC and AI series are non-self priming, horizontal multistage centrifugal pumps. Pump is coupled with motor at the same shaft and mounted on a base-plate. The friendly design makes the pump suitable for installation in the small domestic or industrial water supply systems. The pump is fitted with a mechanical seal and through-going pump-motor shaft. AC: The discharge and suction chamber are made of cast iron. The other parts of pump in contact with the liquid are made of stainless steel. Operating conditions Liquid: Clean liquid without solid particles. Liquid temperature range: C~+9 C Maximum ambient temperature: + C AI: All parts of pump in contact with the liquid are made of stainless steel. EPDM O-rings is standard. Viton for option. Motor Pipe connections The pump is fitted with a totally enclosed, fan-cooled, squirrel-cage motor. Connections Suction port Rated speed: 3rpm/z Discharge port Enclosure Class: IP Drain hole, priming hole: Insulation Class: F Standard Voltages: x/v(.~.p) x~v(.~3.p) 3x~ /3~Y V(.~.P) 3x~77 /3~Y V(.~.P) Mechanical seals List of Materials Q: Silicon carbide B: Carbon U: Tungsten carbide E: EPDM V: Viton C: Seal Type (general use) A: Seal Type (machine tool use) * Spring is SS3. The maximum operating pressure depends on the temperature of the pumped liquid, see table: Max. operating pressure AC/AI-M, M AC-M, M kg/cm C~+ C C~+ C kg/cm + C~+9 C + C~+9 C Min. inlet pressure: According to the curve + a safety margin of.m. Max. inlet pressure: Limited by the max. operating pressure. Mechanical Seals CQB CQQ AUU Standard O-rings E V AC/I AC/I AC AC 3/ / 3/ / / / / / / AC/AI Construction & Material No Description Suction chamber Pump head Intermediate chamber Impeller Spacing pipe Shaft Mechanical seal O-ring Drain and priming plug Base plate AC Cast iron Cast iron SS3 SS3 SS3 SS3 Silicon carbide/carbon EPDM Steel Steel AC/I, AC, Materials AI SS3 SS3 SS3 SS3 SS3 SS3 Silicon carbide/carbon EPDM SS3 SS
4 9 7 AC/I - AC/I - AC / AI ISO 99 Annex A z 3rpm AC/I - AC / AI ISO 99 Annex A z 3rpm AC/I - 3 AC/I -3 AC/I -3 3 AC/I - 3 AC/I Electrical data, 3 min Pump type X - V 3 X - / 3- Y V P /3. 7.9/../..7/.9 3.7/ / / / / /.-. AC/AI - AC/AI -3 AC/AI - AC/AI - AC/AI - - Pump type X - V Electrical data, 3 min 3 X - / 3- Y V P(W) I /(A) P P(W) I /(A) P P(W) I /(A) P P(W) I /(A) AC/AI - AC/AI -3 AC/AI /.7./..3(V) / / /
5 AC - AC ISO 99 Annex A z 3rpm AC - AC ISO 99 Annex A z 3rpm AC -3 AC AC - AC - 3 AC - AC Q[m 3 /h] Q[m 3 /h] Q[m 3 /h] Q[m 3 /h] Electrical data, 3 min Pump type X / V 3 X - /3- V P(P) P(W) I /(A) P(P) P(W) I /(A) AC - AC - AC /.9.9 (V) / / / X -77 /3- V AC -. (V) 3.-.9/ Electrical data, 3 min Pump type X / V 3 X - /3- V P(P) P(W) I /(A) P(P) P(W) I /(A) AC - AC - 9.(V) / / X - /3- V AC -3 AC / /.-.
6 EVAK PUMP TECNOLOGY CORP. AC, Dimensions & Weights AI, Dimensions & Weights B B L Rc 3/ Rp B B L Rc 3/ Rp AI : Rp AI : Rp / AC : Rp AC : Rp / Rc 3/ Rc 3/ L L3 L L L3 L Pump type AC - AC -3 AC - AC - AC - AC - AC -3 AC - Dimension (mm) B L L L3 L B phase 3phase AC, Net weight (kg) phase 3phase phase 3phase AI, Pump type Dimension (mm) Net weight (kg) B L L L3 L B phase 3phase phase 3phase phase 3phase AI - AI -3 AI - AI - AI - AI - AI -3 AI
7 EVAK PUMP TECNOLOGY CORP. AC Dimensions & Weights AC Dimensions & Weights AC AC Pump type AC - AC - AC -3 AC - L L L3 L B Dimension (mm) B Fig. AC -Phase Net weight (kg)... Pump type AC - AC - AC -3 AC - L L L3 L B Dimension (mm) 3 B Fig. AC -Phase Net weight (kg). Pump type AC - AC - AC -3 AC - L L L3 L B Dimension (mm) B Fig. AC -3Phase Net weight (kg)..3.. Pump type AC - AC - AC -3 AC - L L L3 L B 9 Dimension (mm) 3 B Fig. AC -Phase Net weight (kg)
8 ABI ABS Z [M] 7 Performance Range z 3rmp Feature Reliability / Compact form / Wide range / igh efficiency / Easy maintenance / Suitable for slightly corrosive liquids Application > Water supply and pressure boosting > Air-conditioning > Water treatment > eating and cooling in industrial processes > Industrial washing and dish-washing machines > Softened water > Pressure boosting of process water > Fertilizer / dosing systems ABI/S 3 ABI/S ABI/S ABI/S 3 Q[L/M] Q[M³/] ABI z ABS z Pump A horizontal, multistage centrifugal pump is made of stainless steel. The pump is a non-self priming type and fitted with a mechanical shaft seal. Liquids to be pumped These pumps are designed for pumping freely flowing non-corrosive, non-explosive, and non-flammable liquids. The liquids to be pumped must also be free of solid matter, sands, fibers, and similar materials. Construction & Material 3 Motor Totally enclosed, fan-cooled standard motor. Rated speed: 3rpm/z Enclosure Class: IP Insulation Class: F Standard Voltages: x~v, z, 3x~3 /3-Y V, z Most common non-highly corrosive watery liquids, oily liquids, hot and cold liquids can be pumped with these pumps. The suitability of these pumps for pumping any particular liquid depends upon a number of factors, such as the ph value, contents of chemicals such as chlorides, oils, the temperature of the liquids, etc.. Operating conditions Liquid temperature range: C ~+ C Maximum ambient temperature: + C Maximum operating pressure: kg/cm² Maximum inlet pressure is limited by maximum operating pressure. Mechanical Seals List of Materials Q: B: E: V: R: *Spring is SS3. Silicon carbide Carbon EPDM Viton Seal Type (general use) Pipe connections Connections Suction port Discharge port Drain hole, priming hole: Mechanical Seals RQQ RQB O-rings E V Standard ABI ABI/S ABI/S / / 3/ 3/ ABS No Description Pump casing Suction inter-connector Chamber Impeller Cover plate Shaft Mechanical seal O-ring Base plate 9 7 ABI SS3 SS3 SS3 SS3 SS3 SS3 Silicon carbide/carbon EPDM Steel Materials ABS SS3 SS3 SS3 SS3 SS3 SS3 Silicon carbide/silicon carbide EPDM Steel
9 9 ABI/S - ABI/S ISO 99 Annex A z 3rpm 7 ABI/S - ABI/S - M ISO 99 Annex A z 3rpm 7 3 ABI/S - ABI/S - ABI/S -3 ABI/S - 3 ABI/S - ABI/S -3 ABI/S - ABI/S - ABI/S Electrical data, 3 min - - Electrical data, 3 min Pump type X- V 3 X - /3-Y V Pump type X - V 3 X - /3-Y V P P(W) I /(A) P P(W) I /(A) P P(W) I /(A) P P(W) I /(A). 39.9/ /.9-. ABI/ABS / / / /.-. ABI/ABS / / / /.3-. ABI/ABS -3 3./..-./ / /.7-.9 ABI/ABS (V) /.7-..7/ /.-.3 ABI/ABS (V) / / /.3-. ABI/ABS - ABI/ABS - ABI/ABS -3 ABI/ABS - ABI/ABS - ABI/ABS
10 ABI/S - ABI/S ISO 99 Annex A z 3rpm ABI/S - ABI/S ISO 99 Annex A z 3rpm ABI/S - ABI/S - 3 ABI/S -M ABI/S ABI/S - ABI/S - Electrical data, 3 min - - Electrical data, 3 min Pump type X- V 3 X - /3-Y V Pump type X - V 3 X - /3-Y V P(P) P(W) I /(A) P(P) P(W) I /(A) P(P) P(W) I /(A) P(P) P(W) I /(A)./ /.3-. ABI/ABS / / (V) /3.-3. ABI/ABS (V) / (V) 9.-.7/ X -77 /3-Y V 3 X -77 /3-Y V ABI/ABS /.3-..9(V) /.-. ABI/ABS /.-. ABI/ABS - ABI/ABS -M ABI/ABS - ABI/ABS - -
11 .ANDLING AC/AI, ABI/ABS Installation and operating manual Before installation, these installation and operating instructions must be read carefully. The product must be lifted and handled with care..applications AC,AI: Designed to handle clean, thin, non-aggressive water and non-explosive liquids, no solid particles. ABI,ABS: Designed to handle clean, thin and non-explosive liquid without particles. That also can be used in light industry application. 3.WORKING LIMITS AC, AI Max. operating pressure: C to + C > kg/cm², + C to +9 C > kg/cm². Liquid temperature range: C ~ +9 C. Max. ambient temperature: + C. Min. inlet pressure: According to the curve + a safety margin of.m. Max. inlet pressure: Limited by the max. operating pressure. ABI,ABS Max. operating pressure: kg/cm². Liquid temperature range: C ~ + C. Max. ambient temperature: + C. Min. inlet pressure: According to the curve + a safety margin of.m. Max. inlet pressure: Limited by the max. operating pressure..installation The pump may be installed as shown in Fig...ELECTRICAL CONNECTION Position of terminal box (Fig.) The terminal box can be turned to three positions before the pump is installed..others (Fig.) Priming Before start up, to fill the pump body and suction pipe through the priming plug, bleeding off all the air. Maintenance No routine maintenance is required. Frost protection Pumps which are not being used during periods of frost should be drained to avoid damage. Remove the priming and drain plugs and allow the pump to drain. Do not replace the plugs until the pump is to be used again. Fault. Pump does not runt when the motor starter is operated.. Pump runs but gives no water. 3. Pump capacity is not constant or is reduced.. Starter overload cut off immediately when the power is switched on. 7.TROUBLE SOOTING Possible cause Supply failure Main contacts in motor starter are not making contact or the motor coil is faulty. Control circuit fuses have cut or are defective. Pump is blocked by unknown matters. Motor is failure. Pump is not fill with liquid. Pump is blocked by unknown matters. The suction or discharge pipe is blocked by unknown matters. The foot or non-return valve is blocked or failure. The suction pipe is leakage. The suction lift is too great. The air is in suction pipe or pump. Pump takes in air. The pump, suction pipe or discharge pipe is partly blocked by unknown matters. The inlet pressure is too low. Wrong direction of rotation (three phase). The suction lift is too great. The foot or non-return valve is partly blocked. Overload setting is too low. The cable connection is loose or faulty. One fuse is blown. Pump is not free to run. Contacts in overload are faulty. The motor winding is defective.
12 . Nameplate 3 Model : P : kw P Supply : V Z S. No. : TYPE Q : LPM : M max : M F.L.A. : Amp Weight : KG 7.Pump Model.Output 3.Voltage.Serial Number.Pump Type.Rated Capacity & ead 7.Electric Current.Pump Weight 9.Maximum ead 9
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP
HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug
More informationCR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ
GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR45-12-2 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos Pump 96122818 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96122818/cr-45-12-2-a-f-a-e-hqqe.html
More informationCR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR1-16 A-FJ-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9651222 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9651222/cr-1-16-a-fj-a-e-hqqe.html
More informationCR64-1 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-1 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123527 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123527/cr-64-1-a-f-a-e-hqqe.html
More informationCR A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html
More informationCR32-4 A-F-A-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR32-4 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 9612213 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612213/cr-32-4-a-f-a-e-hqqe.html
More informationCRN A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN45-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96123118 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn45/96123118/crn-45-2-2-a-f-g-e-hqqe.html
More informationCR A-F-A-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CR9-1-1 A-F-A-V-HQQV 3x4D 5 HZ Grundfos Pump 9612486 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/9612486/cr-9-1-1-a-f-a-v-hqqv.html
More informationKQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800
KQ Series Multistage Booster Pump System Installation Manual KQ200/400 KQ800 ISO 9001 Certified Description The KQ series booster pump is an all-in-one compact and reliable automatic multistage centrifugal
More information2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C
MADE IN ITALY DATA SHEET Horizontal Two Stage Centrifugal Pumps 2CP 20 2CP 32/20A 00 2CP 32/20B 80 2CP 32/200B HEAD [m] 60 2CP 32/200C 40 20 0 2 4 6 8 0 2 4 6 3 FLOW [m /hr] Linz Electric is a brand of
More informationCRN90-1 A-F-G-V-HQQV 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN9-1 A-F-G-V-HQQV 3x4D 5 HZ Grundfos Pump 96124237 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn9/96124237/crn-9-1-a-f-g-v-hqqv.html
More informationSSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials
The SSA series is an All-in-One self-priming silent booster pump, the compact design combined pressure tank, pressure switch, flow switch and full protection controller, moreover, the evolutional flow
More informationCR20-07 A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR2-7 A-F-A-E-HQQE 3x4/69 5 HZ Grundfos pump 965513 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/965513/cr-2-7-a-f-a-e-hqqe.html
More informationGRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz
GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance
More informationCR A-F-A-E-HQQE 3x400/ HZ
GRUNDFOS DATA BOOKLET CR32--2 A-F-A-E-HQQE 3x/69 5 HZ Grundfos pump 9612212 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/crfam/9612212/cr-32--2-a-f-a-e-hqqe.html
More informationFor calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1
Centrifugal Pump Single Shaft Seal 2 Freephone lines are open between 8.00am and 5.30pm Monday to Friday FREEFAX: 0800 801404 TETRA PAK PUMPS Centrifugal Pump Single Shaft Seal Motors: 3000 r/min, 3-phase
More informationGRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz
GRUNDFOS DATA BOOKLET Grundfos booster systems with two or three CM, CMV or CR pumps 50 Hz Table of contents 1. Product introduction 3 2. Performance range 4 with CM pumps 4 with CMV pumps 4 with CR pumps
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationCompany name: Created by: Phone:
Position Qty. Description 1 SL1..1.55..6G.C Product o.: 9655 ote! Product picture may differ from actual product on-self-priming, single-stage, centrifugal pump designed for handling wastewater, process
More informationTP /4-A-F-A-BQQE 400D 50HZ
GRUNDFOS DATA BOOKLET TP 15-7/-A-F-A-BQQE D 5HZ Grundfos pump 989838 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/tp/989838/tp-15-7--a-f-a-bqqe.html
More informationSL S.S.N.51D
GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html
More informationPressurisation units & expansion vessels
Pressurisation units & expansion vessels Pressurisation units The new generation of microprocessor controlled pressurisation units Standard Unit/Advanced Unit These microprocessor controlled pressurisation
More informationV80-H Multistage Pump Instruction Manual
V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming
More informationVADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY
PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming pumps. They warrant high hydraulic and
More informationGRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz
GRUNDFOS DATA BOOKLET Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz Table of contents 1. Product data 3 Introduction 3 Performance range 4 Product range 6 Type key 9 Operating conditions
More informationCLOSED COUPLED CENTRIFUGAL PUMPS
0 Third Street Piqua, Ohio 6-060 www.pumpagents.com PumpAgents.com - Click here for Pricing/Ordering SERIES G--/ G6--/ SECTION B PAGE ISSUED /0 REPLACES /0 CLOSED COUPLED CENTRIFUGAL PUMPS 00RPM - 60Hz.
More informationSeries SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec
WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec Series SR Compact Centrifugal Mag-Drive Pumps Providing environmentally safe sealless, magnetic pumps of the highest quality for over 30
More informationVertical In-line Self-Priming liquid ring Centripetal pump TYPE - STP
investa Vertical In-line Self-Priming liquid ring Centripetal pump TYPE - STP Excellent for handling solvents from the drum and tank farm Low NPSH required Negative suction lift upto 5 mts. Low speed Compact
More informationSELF-PRIMING JET PUMPS
SS Anti-Rust SS Shaft Copper & Cold-rolled SELF-PRIMING JET PUMPS CONTENTS 1. Applications.... Model Description.... Technical Data... 4. Implementation Standards... 5. Safety Precautions... 6. Product
More informationGRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz
GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve
More informationAcquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2
CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 Congratulations on your purchase of a LEO Centrifugal Pump It is important that you read, fully understand and observe the following
More informationSECTION STEAM CONDENSATE PUMPS
SECTION 23 22 23 - STEAM CONDENSATE PUMPS PART I - GENERAL 1.1 SECTION INCLUDES A. Steam Condensate Return Units, Gravity Return Type 1. Receiver 2. Pumps 3. Control Panel 4. Accessories Note to PSC: Although
More informationB.K. Machinery (M) Sdn. Bhd. Submersible Pumps. Flexible Vibrator Poker. 1 of 6. Other Construction Machinery
B.K. Machinery (M) Sdn. Bhd. Submersible Pumps Brand YOKO Flexible Vibrator Poker Brand YOKO 1 of 6 Concrete Cutter Power Trowel 2 of 6 Portable Lifting Hoist Concrete Mixer 3 of 6 Bar Cutter, Bar Bender
More information1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide
1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide Installation Location! The pump should be located as close as possible to the liquid source so that the suction line can be as short and direct
More informationLHW HIGH HEAD DRAINAGE PUMPS
www.tsurumi-global.com LHW HIGH HEAD DRAINAGE PUMPS Submersible High Head Drainage Pumps Tsurumi LH/LH-W series pumps are submersible heavy-duty pumps specialized for high head. These pumps are available
More informationUPZ PUMP POWER FOR TOP PERFORMANCE UNDER
Submersible borehole pump People at KSB we make your world flow round! UPZ PUMP POWER FOR TOP PERFORMANCE UNDER THE TOUGHEST CONDITIONS UPZ is top choice wherever submersible borehole pumps have to satisfy
More informationFBSMS FLUX BOOSTING SYSTEMS
FBSMS FLUX BOOSTING SYSTEMS Aplications FLUX BOOSTING SYSTEM is made up of a water pump and an electronic pump controller which is used for: Residential irrigation applications when is necessary to boost
More informationEVMSU - Vertical Multistage Pumps. Product Catalog
EVMSU - Vertical Multistage Pumps Product Catalog www.pumpsebara.com Built like a Kata a A Katana is a traditional Japanese sword made with distinctive, longstanding expertise started in 300 A.D. Katana
More informationIMMERSIBLE PUMPS FOR INDUSTRY
GRUNDFOS INDUSTRIAL SOLUTIONS Grundfos MTR, MTH, MTA, MTS pumps IMMERSIBLE PUMPS FOR INDUSTRY COMPACT TANK TOP SOLUTIONS FOR DEMANDING APPLICATIONS RENOWNED FOR THEIR RELIABILITY AND PRECISION MTA MTH
More informationDUPLEX CONDENSATE TANK SYSTEM
DUPLEX CONDENSATE TANK SYSTEM PROJECT NAME: 7 EAST 54TH STREET CONTRACTOR: PRO PUMP CORP ENGINEER: KEVAN WOODWORTH SUBMITTED BY: NISSIM ISAACSON DATE: 2.20.205 DESIGN DATA Model GPM TDH HP Volt Phase RPM
More informationGSZ/GSD HIGH VOLUME DEWATERING PUMPS
www.tsurumi-global.com / HIGH VOLUME DEWATERING PUMPS Submersible High Volume Dewatering Pumps Tsurumi and series of submersible heavy-duty pumps deliver high volume discharge. This former consists of
More informationVogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM
Vogel Pumpen Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed
More information4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction
4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation
More information12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS
12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS 12/50 INDEX.................
More informationKTZ KTD DEWATERING PUMPS
www.tsurumi-global.com KTZ KT EWTERING PUMPS Submersible eavy-duty ewatering Pumps The KTZ-series is Tsurumi s flagship line of submersible pumps. Made with a cast iron body and high chromium cast iron
More informationInline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax
Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Design LR, LMR Technical Data Performance: m Capacity up to 350m 3 /h (1540USgpm)
More informationAmerica s Most Versatile Line of Centrifugal Pumps
America s Most Versatile Line of Centrifugal Pumps OEM Development Price Pump Co. has a storied history of developing products specific to the requirements of many original equipment manufacturers in industry
More informationKTV DEWATERING PUMPS
www.tsurumi-global.com DEWATERING PUMPS Submersible Lightweight Compact Dewatering Pumps Tsurumi -series features submersible pumps of lightweight compact design. The pump body is made of die-casted aluminium
More informationGRUNDFOS PLUMBING & HVAC PRODUCTS
GRUNDFOS PLUMBING & HVAC PRODUCTS SERIES UP CIRCULATORS GRUNDFOS CIRCULATORS FOR HEATING AND HOT WATER RECIRCULATION Quiet, maintenance-free performance Stainless steel construction, corrosion resistant
More informationUP/UPS-B/UPN Hot Water Service Circulators
UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers
More informationPENGUIN SERIES HSC PUMPS INTRODUCTION
PENGUIN Installation & Maintenance SERIES HSC PUMPS MODELS HSC-1/4 HSC-1/2 HSC-3/4 HSC-1 HSC-2 HSC-3 SEALS S - Single D - Double M - Single/Multi-Stage INTRODUCTION Penguin 316 stainless steel centrifugal
More informationJET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS ABOVE GROUND PUMPS
A NORMA Group brand JET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS 1300 252 677 sales.au@normagroup.com www.normagroup.com.au A
More informationTQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.
TQ Series Electronic Control Pump Instruction Manual 50Hz ISO 9001 Certified Walrus Pump Co., Ltd. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No. 83-14, Dapiantou, Sanjhih
More informationMECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More information1 of 6 ALLEN GWYNNES PUMPS SDN BHD. AGL 150 Pump (Hydrocyclone Pumps) AGP/AGL Catalog ALLEN GWYNNES
ALLEN GWYNNES PUMPS SDN BHD AGL 150 Pump (Hydrocyclone Pumps) Hydrocyclone pumps is use to pumping abrasive solid such as sand always leads to damages to the pumping unit.the output of the cyclone pump
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationInstallation & Maintenance Manual
Installation & Maintenance Manual MOL 200 S1L (B30A) Oil Burner 11/12 Tel: +44 (0) 1905 794331 Fax: +44 (0) 1905 794017 Email: info@nu-way.co.uk Web: www.nu-way.co.uk DESCRIPTION COMPONENTS 1. Shrouded
More information489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationVolute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)
Volute Casing Pumps Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0)31 721 52 24 FR: +41 (0)21 905 10 80 Technical Data Performance: m Capacity up to 600m 3 /h (2640USgpm) m Head up to 100m (330feet)
More informationPRESSURE ASSEMBLIES WITH ONE PUMP
PRESSURE ASSEMBLIES WITH ONE PUMP WATERPRESS / WATERPRESS / The WATERPRESS / and / are booster sets produced with NEWJET self-priming centrifugal pump. They are supplied wired, tested and complete with
More informationKTZ KTD DEWATERING PUMPS
www.tsurumi-global.com KTZ KT EWTERING PUMPS Submersible eavy-duty ewatering Pumps The KTZ-series is Tsurumi s flagship line of submersible pumps. Made with a cast iron body and high chromium cast iron
More informationCENTRIFUGAL PUMPS OPERATING INSTRUCTIONS
CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS This operating manual covers
More informationmarine horticulture recycling
Stuart offers a range of solutions for water transfer, pressure boosting and submersible pump applications. Together with water conditioning, pressurisation units and a range of high quality unvented hot
More informationCombiBloc Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More informationARBO Chemical pumps SealPro with mechanical seal. Product group 1.1
ARBO Chemical pumps SealPro with mechanical seal Product group 1.1 Product group 1.1 SealPro Applications For all transport or circulation duties of corrosive liquids, even high viscosity, with maximum
More informationCH & EQ centrifugal pumps. High efficiency for cost-effective pumping
CH & EQ centrifugal pumps High efficiency for cost-effective pumping What does it cost to run a pump? On average, a centrifugal pump should last at least 15 years. During that time, energy consumption
More informationCPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:
CPE RANGE PUMPS CPE RANGE PUMPS MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos: 7120305 7120310 7120315 7120320 7120325 7120330 OPERATION & MAINTENANCE INSTRUCTIONS GC0514 Contents Specifications...
More informationCombiBloc. Close-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of SPX FLOW 's Johnson Pump brand Combi-system,
More informationVertical Multistage. HP Phase Voltage Amps
Models UWH thru UWH, UWJ0 thru UWJ and UWK0 Stainless Steel Models UWK thru UWK and UWL0 thru UWL Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions
More informationThe Replacement Motor & Fan Specialists
The Replacement Motor & Fan Specialists Residential Commercial Electric Motors Fans & Blowers Hydronic Pumps Accessories www.soperssupply.com Industrial Soper s Supply Ltd. Proud Distributor of the Following
More informationDewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a
2 Dewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a complete pump range for reliable dewatering. This
More informationMECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION pumps are Hi-Tech single stage, horizontal centrifugal pumps with magnetic driven coupling. In compact and silent close-coupled execution, they can be mounted on to B5 frame motors.
More information489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications
More informationSERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model
Section: MOYNO 500 PUMPS Page: 1 of 4 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and 36752 Model DESIGN FEATURES Housing: Cast iron/316 SS
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview
More informationTECHNICAL. Series 18. Pump Packages
TECHNICAL S Y S T E M S Series 18 Pump Packages Series 18 Pump Packages Standard Features Close-coupled, end-suction, centrifugal pumps Mounted and wired pump starters Hand-Off-Auto switch for each pump
More informationVogel - Blockpumps. Design LMN / LM
Vogel - Blockpumps Design LMN / LM 1 Materials: Design LMN, Sizes DN 32-80 Design LM, Sizes DN 100-150 Performance: Capacity up to 500 m 3 /h (2200 USgpm) Head up to 95 m (312 feet) Speed up to 2950 min
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More informationChemical Pumps Vertical Chemical Pump Type TNP
Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis
More informationUSER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING
USER S MANUAL VCU/ Series CENTRIFUGAL FAN IN SCROLL CASING 2 CONTENTS Introduction Use Delivery set Designation key Technical data Safety requirements Design and operating logic Mounting and set-up Connection
More informationModel 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series
PumpAgents.com - Click here for Pricing/Ordering Model 6050-Series SELF-PRIMING PUMPS FEATURES Body: Impeller: Shaft: Wearplate: Shaft Seal: Ports: Motor: Weight: Bronze Construction JABSCO Nitrile 316
More informationCentrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL
Centrifugal Pumps acc. to EN 22858 / ISO 2858 with Shaft Sealing Type NCL General The DICKOW centrifugal pump acc. to EN 22858 / ISO 2858 is designed for handling liquids in the chemical and petrochemical
More informationMARLOW PUMPS RECIRCULATION
End suction centrifugal pump line available in both close coupled and frame mounted configurations allow users to meet exactly most flow conditions on commercial pool and waterpark applications. Features
More informationPDF # GRUNDFOS END SUCTION PUMP EBOOK
21 February, 2018 PDF # GRUNDFOS END SUCTION PUMP EBOOK Document Filetype: PDF 131.94 KB 0 PDF # GRUNDFOS END SUCTION PUMP EBOOK Complete range of Booster pump sets available as package. The Grundfos HS
More informationPREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS DB & SP SERIES
PREMIUM MAGNETIC-DRIVE SEALLESS CENTRIFUGAL PUMPS PUMPING SOLUTIONS AROUND THE WORLD QLVKWKRPSVRQ FRP DB SERIES SP SERIES MAGNETIC DRIVE, SEALLESS, CENTRIFUGAL PUMPS DB SERIES FLOODED SUCTION Backed by
More informationNON-SUBMERSIBLE WATER PUMP
NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationGRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz
GRUNDFOS DATA BOOKLET Circulator pumps 60 z Table of contents 1. Product introduction 3 Features and benefits 3 Applications 3 2. Performance range 4 4 D single-head operation 5 D twin-head operation 6
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions
More informationCleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2
Cleaning unit for coolant :_decftez`_>r_fr] Book No.: 1271526-02 V2 Alfa Laval Separation AB Separator Manuals, dept. SKEL S-147 80 Tumba, Sweden Telephone: +46 8 53 06 50 00 Telefax: +46 8 53 03 10 40
More informationGoulds Trash Hog. Self-Priming Solids Handling Pumps
Goulds Trash Hog Self-Priming Solids Handling Pumps Goulds Trash Hog Self-Priming Pumps Designed for Toughest Solids Handling Services Capacities to 6000 GPM (1363 m 3 /h) Heads to 140 feet (43 m) Temperatures
More informationPump WaterVISE, FloVISE
General information It is important that this manual is read carefully by the user and the installer in order to ensure proper functioning and lifespan of the pump. Pahlen pumps are manufactured in accordance
More informationWash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark
Wash and Clean By Michael Rasmussen, Industry application team, Grundfos, Denmark Introduction Wash & Clean systems for the food processing industry is an utility application that sets high requirements
More informationPatterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationSECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.
SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15410 - Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections. 1.02 SUBMITTALS A. Submit properly identified
More informationdualarm Vertical In-Line Pumps
Series 430 & 438 dualarm Vertical In-Line Pumps FILE NO: 43d.1 DATE: Jan. 0, 010 SUPERSEDES: 43d.1 DATE: Sept., 008 Series 430 & 438 Smart pumps for the commercial HVAC market. Armstrong Vertical In-Line
More informationSpecifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95
Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B-95 394A-95 thru 394D-95, 399A-95 Please read and save this Repair Parts Manual. Read this manual and the General Operating
More information