Incinerator Model A1600 -Oil
|
|
- Arron Johnson
- 5 years ago
- Views:
Transcription
1 Incinerator Model A1600 -Oil Operators Manual Important Failure to cure refractory Before using will void warranty (See refractory curing procedure) Tampering with orifices in the burner will void warranty Revised July 2006
2 Owners Manual For Oil Fired Incinerator Models A1600 Index CE certification Page 3 Overview of Incinerator Page 4 Specifications Page 5 Service / installation sheet Page 6 Site plan / fitting Page 7 Assembly Instructions Page 8 Commissioning & start up procedures Page 9 Operator instructions Page 9 Refractory Curing Procedure Page 10 Inspection & Servicing Page 11 Maintenance Programme Page 12 Recommended Housing Plan Page 13 Fitting Chimney through roof (dia.) Page 14 Warranty Page 15 1
3 Features Overview Designed for economical performance. Up to 750 kg capacity. Low profile for easy loading and ash removal. Refractory lined to retain heat for efficient operation. Fuel Efficiency Rapid incineration means low fuel consumption. Higher burn rate than smaller models. Thick refractory lining in main chamber retains heat, increasing efficiency. Quality Built to Last Heat resistant aluminized steel. Stainless steel stack. Backed by over 30 years of incineration experience. 2
4 Specifications Summary All installations must be in accordance with state and local codes. WASTE CHAMBER Chamber capacity (Type IV waste - animals) 750 kg Chamber volume 1.18 m 3 Chamber size Width 180 cm (outside) Height 330 cm Including weights Length 311 cm Door opening 200 x 77 cm Height to top of stack 3.1 m BURNERS Operation Oil burner Diesel 2 x burners ELECTRICAL SERVICE Standard volt, 50 HZ, 10 amp We reserve the right to alter specifications without prior notice Installation Must be installed in accordance with local codes and ordinances, subject to regulatory agencies. Stack test data is available from the distributor for permit application. If on-site testing is required, it is the responsibility of the purchaser and can be arranged through the distributor. Outside installation is recommended with a simple metal roof or three-sided metal shelter, providing a minimum four foot clearance from any combustible material. Inside installations may have special insurance requirements. Factory must be advised. 3
5 Inciner8 Incinerator Model A1600 Installation Location: Installed by: Date: Sold By: Service Record Date Comments 4
6 Site Information 1. The A1600 incinerators are designed to be in a covered installation on a concrete slab, which should be smooth and impervious to aid in cleaning around the incinerator area. Drainage or some bunding around the incinerator area is ideal to avoid any waste materials running off the concrete slab. 2. The A1600 may be installed in a three-sided shelter, but must comply with local building and fire codes for clearances from combustible walls and materials, with ample ventilation (also allow for wind direction). A minimum clearance of 1.25m around the incinerator is recommended for service and maintenance. 3. The incinerator should be sited away from animals, feed or bedding areas. For health and safety reasons the incinerator area should be kept locked at all times when not supervised. Please note that it is essential to use an authorised technician for the electrical and fuel installation and inspection Electrical Service 220 Volt, 50/60 HZ, 10 Amp 1. Electrical service can be supplied by plugging into the cord set. NOTE: Polarity must be maintained or the burners will not operate. If burners lock out after approximately 5 seconds and the blower continues to operate, then the polarity is incorrect. It should be corrected at the power source, not in the incinerator control. Fuel Assemble the tubing, oil filter, cut-off cock and fittings between the tank and burner. (NB tubing between the oil tank and burner to be supplied by the customer) Oil Tank Since tanks vary in size and fixtures, additional piping may be needed. It is important that a filter be provided in the line between the tank and the incinerator. There must be a flow and return pipe with two pipe system If the flow outlet is on the underside of the tank, extend a threaded nipple about 5cm into the tank to avoid problems from dirt / condensation in the bottom of the tank Please note that single pipe installation is advisable using a tiger loop. 5
7 Assembly Instructions Site 1. Position the incinerator on the concrete slab as needed for fuel and electrical hook up. Primary Chamber 1. (IT IS VERY IMPORTANT THAT THE DOOR IS NICELY BALANCED AND MAKES A FIRM SEAL AROUND THE WHOLE CASE WHEN CLOSED SHUT FAILURE TO DO THIS CAN RESULT IN THE INGRESS OF COLD AIR ALLOWING DAMAGE TO THE REFRACTORY LINING WHEN HOT) 2. Slide out counterbalance arm and secure in place with the 3 x bolts supplied. Slide out counterbalance arm and bolt into place (See above, before and after) Stack / Chimney Burner 1. Slide on the stainless steel stack over the chimney outlet on the secondary chamber and bolt into place. 1. Attach the 2 x burners at each burner port. 2. Attach the burner plugs to the relevant plug on the control box, i.e AA to AA, BB to BB 3. Connect the pipe work including pressure gauge. 4. Place the steel burner covers over each burner. Temperature Probes 1. Slide the temperature probes in each location (2) Location 1 is at the rear, top of the secondary chamber. 2. Location 2 is approx 60cm below the control box 6
8 Control Box 1. Connect the electrical control box to a power supply. (Use a qualified electrician) 2. Place the box on the mounting plate Control box settings Timer 1-10 minutes Timer 2-6 hours (Includes 40 minute secondary chamber pre warm) Timer 3-9 hours (Includes 40 minute secondary chamber pre warm) Timer 4-12 hours (Includes 40 minute secondary chamber pre warm) 7 NB Once the cycles have finished the burner fans will remain on for 8 hours for cool down.
9 Commissioning and start up procedures 1. It is imperative that the refractory has been cured (see page 10 for details) 2. All pipe work must be checked for leak tightness and should be free from dirt and debris. Welding slag needs to be removed and the pipe work should be completely clear of any obstruction. 3. It is important that the burner is set correctly by adjusting the air / fuel flow. When looking at the burner flame it should not be producing black smoke at the ends of the flames, small adjustments should be made to lean the flame so that it is clean. The above should also be checked after periods of shutdown. OPERATOR INSTRUCTIONS Curing of the refractory is essential prior to burning the first load of waste. 1. The incinerator should not be modified in any way not in keeping with the manufacturers instructions, this will not only void warranty but will possibly fail to meet ABPR (UK) 2. Dedicated tools should be used for use with the incinerator only, and not be used elsewhere. 3. REMOVE ASHES before loading the incinerator. 4. NOW LOAD THE INCINERATOR. 5. Select the required time (nos. 2-4, see above) to ignite the burner, (Number 1 is for commissioning only) 6. The secondary burner will operate for about 40 minutes, then the primary burner will ignite. (Ensure that the temperature is reading 850 deg C or above, otherwise Restart the process. 7. Dependant on which time setting has been selected (also dependant on size of load to incinerate) 8. Lock the unit door to ensure that no one can inadvertently access the chamber during the burn 9. An optional temperature cut off device can be fitted where needed. 10. The burners will AUTOMATICALLY SHUT OFF when the chosen burn time is completed. The fan should remain on for a period of time (normally 8 hours) after the burn cycle or when the primary chamber is less than 50 deg C or less 11. For the best results BURN DAILY TO A WHITE ASH 12. Do not store carcasses in the incinerator chamber. Singe and burn does not constitute an approved pre-incineration storage process. 13. In case of any form of breakdown, shut down the burner immediately (if possible leave fan running). 8
10 Refractory Curing Procedure Curing process should be done using control panel settings DAY 1 Start Burner using number 1 timer position Allow cooling for 10 minutes ON 50 minutes REPEAT THIS 12 (TWELVE) TIMES. I.E. OVER A 12 HOUR PERIOD DAY 2 Start Burner using number 2 timer position Allow cooling for 6 Hours ON 6 Hours The unit is now ready to operate normally Total Burner Time 8 hours There will be hairline cracks and minor scaling of the refractory when curing is completed. This is a normal result of the curing process 9
11 Inspection Procedures Periodic inspection and servicing of the units is required to maintain optimum operation We recommend the following schedule: - Assuming the unit has been installed and tested by a suitably qualified gas/ electrical engineer. 1 st service (post installation check up) after 50 hours of operation Regular service/ inspection 1000 hours or annually, whichever is the sooner. Service / Inspection procedures should include.. 1. Check for leaks in all pipe-work and gas supply 2. Check for leak tightness of the unit ensuring all waste gas travels up the chimney output 3. All safety shut off valves and safety guards should be inspected. 4. A temperature and combustion analysis should be performed to ensure that there is no deterioration of incinerator performance. 5. Timers should be calibrated to ensure that they reflect a true reading and ensure that the safety cut off applies. 10
12 Incinerators - Recommended Maintenance Programme Main Chamber Open the chamber door and check around the rim of the chamber for leakage, this is normally easily visible as there may be blackening beyond the area where the door seats. If there is blackening and therefore leakage, then the fire cord around the door / lid should be checked and replaced if damaged. Close the door and inspect for any signs of gaps when tightly closed. Adjustments may need to be made to the locking catch to tighten the seal, also the counterbalance weights may need to be adjusted so that they allow the lid to sit firmly, (normally the lid should be balanced, allowing easy opening and closing with one hand). Check for leak tightness of the unit ensuring all waste gas travels up the chimney output Check the integrity of the main chamber refractory lining. When the unit is cool, it is normal to see hairline cracks; these disappear when the unit is hot. Any large chips or cracks can be simply filled with an approved fire cement (approved to 1500 deg C). Check the burner outlet hole and make sure that the area is clear from any debris and that the integrity of the refractory liner is good. Check all around the outside of the chamber for any bent or buckled steel (this can arise from corroded internal refractory lining. Any damage needs to be investigated and resolved internally before making any external repairs or welds. Check all external bolts for corrosion (especially if unit is located outside) and replace where necessary. Discolouration of the stainless chimney stack is normal, although watch for corrosion where the stack meets the steel chamber (especially where units are located inside but the stack is incorrectly fitted through the roof allowing water to run down the outer skin of the chimney) see page 14. Check for leaks in all pipe-work and gas supply All safety shut off valves and safety guards should be inspected. A temperature and combustion analysis should be performed to ensure that there is no deterioration of incinerator performance Timers should be calibrated to ensure that they reflect a true reading and ensure that the safety cut off applies. Check burners for correct setting (see installation manual on set up procedures), the air / fuel mix should be set so that there is no black smoke at the flame tips and there is not excessive fuel use. Where necessary it is possible to remove any corrosion or discolouration (normally on units kept outside) using a wire brush and rust remover. The un its can be re-sprayed in those places (matching heat resistant paint available from Inciner8) Tighten up and inspect any bolts which will have loosened due to settlement, especially where the secondary chamber meets the primary chamber. 11
13 Model A1600 Suggested Building Layout LOADING DOOR Secondary Chamber Counterbalance Arm Title: Model A1600 Building Layout Author: Date: V Ferguson 11th July 2006 Sheet: ONE Revision: 3/2
14 12
15 Limited Warranty Warranty Inciner8 Ltd, warrantor, warrants to the original purchaser of one (1) year or 1000hrs (whichever is earlier) from date of purchase or delivery to original purchaser, products manufactured / supplied by it which are installed and operated according to Warrantor s instructions that are furnished and/or are available to purchaser upon request, and installed according to other applicable federal, state, government and local codes or regulations and upon substantiation that said products were installed correctly, were not abused and are defective. The exact nature of said warranty and exclusive remedy for breach by warrantor is as follows: - Warrantor will repair or replace at Warrantors expense, products found to be defective in workmanship or material. If a problem occurs which the purchaser believes is covered by his warranty, then the purchaser shall contact the seller giving the seller sufficient information to enable a resolution of the problem. Cost of delivery and installation of said parts are not covered under warranty. No product or part thereof may be returned pursuant to this warranty without first receiving specific written permission to do so. All requests should be addressed to the dealer or Inciner8 Ltd, Inciner8 House, Balmoral Drive, Balmoral Business Centre, Southport, PR8 9PZ, United Kingdom, requesting specific authority for returning merchandise pursuant to this warranty with reasons for the request. Limitations Products which are abused or neglected are not covered under this warranty, including overfilling / overheating units, or covering burner outlets (please refer to manual for usage instructions). Warrantor shall not be responsible for the costs of removal or reinstallation of its products and shall not be liable for transportation costs to and from its plant. Further. Warrantor shall not be liable for replacement, repair or refund for component parts not manufactured by it. Failure to cure the refractory (see manual) will immediately void the warranty. Use of parts for modification or repair of the unit or any component not authorised or supplied by Inciner8 Ltd, specifically for this product shall void the warranty. Implied warranties of merchantability and fitness for a particular purpose are limited to the same period of time as this express limited one (1) year warranty or 1000hrs (whichever is earlier) and are specifically disclaimed thereafter. Items Not Covered Under Warranty Nozzles (burner) Fire rope Temperature Probe Inciner8 Ltd shall not be liable for any incidental, consequential, special or contingent damages or expenses arising directly or indirectly from any defect in the product hereby warranted. The warranty shall be VOID if solvents or other highly inflammable fluids such as but not limited to Benzene, methyl ethyl, ketenes, toluene, xylene or naphtha are burned in or mixed with oil for burning in used oil fired burning heaters or furnaces. Inciner8 Ltd is not responsible for any undertaking, representation, or warranty made by any dealer, distribution, or other persons, beyond those expressly set forth in this warranty. 13
FOR EASY, FAST INSTALLATION AND FOR RESULTS
Page 1 INSTALLATION & OPERATING INSTRUCTIONS FOR FEDERAL FLOOR FURNACE OFB-100 AND OFB100L UNPACK SHIPMENT CAREFULLY AND INSPECT FOR DAMAGE. ALL GOODS ARE CAREFULLY MANUFACTURED, INSPECTED, CHECKED, AND
More informationBurn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:
Burn Easy Installation Instructions LP or Natural Gas Fired Units Cremator Setup: 1. Place cremator, outdoor on a solid base consisting of concrete or gravel. Keep this site free of all vegetation. Combustibles
More informationCorn Flame Energy Corn Stove Model 3000
Corn Flame Energy Corn Stove Model 3000 Installation and Operation Guide Read thoroughly before starting installation Save this manual for future reference SAFETY NOTICE If this stove is not properly installed,
More informationINSTALLATION AND OPERATING MANUAL
Dickinson Marine (1997) Ltd 407-204 Cayer Street Coquitlam, B.C. Canada V3K 5B1 www.dickinsonmarine.com dmarine@dickinsonmarine.com INSTALLATION AND OPERATING MANUAL This manual MUST be read carefully
More informationModel No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL
Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL PLEASE SAVE THESE INSTRUCTIONS WARNING: READ THIS OWNER S MANUAL
More informationIMpORTANT SAFETy INSTRUcTIONS
Table of contents SAFETy SETUp OpERATION MAINTENANcE Safety... 2 Specifications... 4 Setup... 4 Operation... 6 WARNING SyMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Diagram... 10 Warranty...
More informationDashley Outdoor Fire Table
Dashley Outdoor Fire Table MODEL N0. 085-557-8 L-FT047PST-F ASSEMBLY INSTRUCTIONS Toll-free 888 670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this
More informationService Parts, Kits and Accessories
The parts identification guides on the following pages have been designed to give a quick reference to component parts used on pilot ignition agricultural building heaters. The guides identify components
More informationINSTALLATION AND OPERATING MANUAL
dickinson since 1932 MODEL 00-NEW-P12000 INSTALLATION AND OPERATING MANUAL Manufactured by: Dickinson Marine (1997) Ltd, 407-204 Cayer Street, Coquitlam, British Columbia, Canada V3K 5B1 www.ahoycaptain.com
More information(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.
(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T www.simplicityvac.com Index Important Safety Instructions............................................................ 2
More informationinfrared paraffin / kerosene / diesel heater
instructions for infrared paraffin / kerosene / diesel heater model no: IR20.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Merchandisers with Air-Over Displays Refrigerated Low-Profile Mobile Merchandiser Refrigerated High-Profile Mobile Merchandiser Refrigerated Grab-N-Go Merchandiser
More informationLaing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual
Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual
More informationFire-Water Bowls Model 100
Fire-Water Bowls Model 100 OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS For your safety: If you smell gas: 1. Shut off gas to the appliance 2. Extinguish any open flame near unit. 3. If odor
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Island Merchandiser FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department IMPORTANT! This manual contains important
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-30P-DDF, CL-20F-DDF, CL-24O-DDF, CL-30-DDF READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual
More informationStoneridge Fire Pit High Dining Table Assembly Instruction
Stoneridge Fire Pit High Dining Table Assembly Instruction Item# L-DN1773SST-D-T WARNING: For Outdoor Use Only. DANGER If you smell gas: 1. Shut off gas to the appliance. 2. Extinguish any open flame.
More informationINSTALLATION AND INSTRUCTION MANUAL
EAPROSUMP10508161MAN UK English INSTALLATION AND INSTRUCTION MANUAL IMPORTANT Never attempt to clean glass sumps with a sharp, blade-like object as this may damage the silicone bond and invalidate the
More informationINSTALLATION AND OPERATION INSTRUCTIONS
Printed in U.S.A. INSTALLATION AND OPERATION INSTRUCTIONS RFPA21A CONSTRUCTION HEATER FLOOR MODEL SAVE FOR FUTURE REFERENCE Space-Ray Division, Gas Fired Products, Inc. P.O. Box 36485, Charlotte, NC 28236
More informationINSTALLER'S MANUAL CLEAN BURN TRANSPORT HEATER MODEL: 45 TH
INSTALLER'S MANUAL CLEAN BURN TRANSPORT HEATER MODEL: 45 TH I89032 PUBLICATION DATE: 4/14/09, Rev. 1 CLEAN BURN PART # 43217 Copyright 2009 Clean Burn, Inc. All rights reserved. No part of this publication
More informationFT982. Electric Professional Fogger. CAUTION: Read and follow all instructions
FT982 Electric Professional Fogger CAUTION: Read and follow all instructions Do Not Return This Fogger To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead Group, Inc. 23
More informationINSTALLATION AND OPERATING MANUAL
INSTALLATION AND OPERATING MANUAL Refrigerated Cases with Air-Over Displays Refrigerated High Profile Grab-N-Go FOR PARTS & SERVICE Contact: Piper Products, Inc. Phone: (800) 544-3057 Ask for Service Department
More informationELECTRIC FIREPLACE INSTRUCTION MANUAL. Item No: 050-HA Model No. FP405R-QA
**WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE. www.dellaproductsusa.com 909. 344. 2588 ELECTRIC FIREPLACE Model No. FP405R-QA INSTRUCTION MANUAL Item No: 050-HA-50099 2 Thank you for choosing
More informationELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR
ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR Model 91797 ASSEMBLY and Operating Instructions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure
More informationDigital Moisture Control Thermostat
Digital Moisture Control Thermostat Installation and Operation Manual PNEG 1711 Date: 2009 PNEG - 1711 Page 1 of 22 06/30/2009 READ THESE INSTRUCTIONS BEFORE INSTALLATION and OPERATION. SAVE FOR FUTURE
More informationARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date
ITEM #0807426 ARMITAGE CEILING FAN MODEL #CC52WW5L Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 17 ATTACH YOUR RECEIPT HERE Purchase Date 4009654 Questions, problems,
More informationGRAND EFFECTS Fire-Water Bowls Model 100
GRAND EFFECTS Fire-Water Bowls Model 100 OWNER S MANUAL / OPERATING AND MAINTENANCE INSTRUCTIONS For your safety: If you smell gas: 1. Shut off gas to the appliance 2. Extinguish any open flame near unit.
More informationTURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual
TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO
More informationCABINET INFRARED HEATER
**WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE. www.dellaproductsusa.com 909. 344. 2588 CABINET INFRARED HEATER INSTRUCTION MANUAL Item No: 050-HA-50082 Thank you for choosing a DELLA Infrared
More informationWKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--
8610 Production Avenue San Diego, California 92121 (858) 566-7465 Fax (858) 566-1943 WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS-- Thank you for choosing a BREEZAIRE cooling unit. We believe
More informationUS 11/2005. Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3. Instruction manual
US 11/2005 Greens Machine VP-1/VP-3 Salad & Vegetable Dryer VP-1 VP-3 Instruction manual The Greens Machine VP-1 and VP-3 Salad & Vegetable Dryer Item Old # New # Description Req. 1 30011 653628 VP-1
More informationOPERATION & INSTALLATION MANUAL
OPERATION & INSTALLATION MANUAL Model: SIO 14 & SIO 18 Electric Tankless Hot Water Generators Table of Contents SAFETY INFORMATION... 1 INTRODUCTION... 2 Unit Operation:... 2 Unit Freezing:... 3 Maintenance:...
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the directions in this manual before
More informationWHAT TO DO IF YOU SMELL GAS
AHE AHE SERIES 4 Direct Vent Wall-Mounted Boilers User s Information Manual If the information in this manual is not followed exactly, a fire or explosion may result, causing property damage, personal
More informationSERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK
STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected
More informationModel RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL
Model RGAC/SGAC Self Contained Cooling/Gas Heat Supersedes: 145.24-O1 (708) Units Form 145.24-O1 (908) MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL CATEGORY III GAS HEATING/ELECTRIC
More informationPressurized Filter Up to 1250 gallons
Pressurized Filter Up to 1250 gallons REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. ITEM #FP1250UV Questions, problems, missing parts? Before returning to your retailer, call our customer service
More informationParts and Service Manual BURNISHER MODEL: MR , MR , MR , MR
Parts and Service Manual BURNISHER MODEL: MR2000-115, MR1500-115, MR2000-220, MR1500-220 TABLE OF CONTENTS RECEIVING YOUR EQUIPMENT... 3 WARNINGS AND SAFETY... 3 ELECTRICAL INFORMATION... 4 GROUNDING INSTRUCTIONS...
More informationOwner & Operator Manual
Owner & Operator Manual NOTE: FOR ULTIMATE SAFETY AND PERFORMANCE, THIS MANUAL MUST BE READ BY INSTALLATION, OPERATING AND HAULER PERSONNEL, PRIOR TO USE OF EQUIPMENT. 23 Craig Street, Unit #6 Brantford
More informationAir Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com
Read and Save These Instructions Horizon Galaxy - Installation and Operations Manual Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC 27505 www.horizondehumidif iers.com 1 Safety Notes: The Horizon
More informationBurgess. Electric Professional Fogger. CAUTION: Read and follow all instructions
Burgess Electric Professional Fogger CAUTION: Read and follow all instructions Do Not Return This Fogger To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead Group, Inc.
More information55-Gallon Dispenser Package
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 666 Rev. A Husky 715 55-Gallon Dispenser Package 100 psi (6.9 bar) Maximum
More informationTABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2
TABLE OF CONTENTS SECTION TITLE PAGE 1. SITE PREPARATION AND INSTALLATION Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2 Installation. 3 Water supply and return.. 3 Pressure/relief
More informationOwner s Manual CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T HEAVY DUTY UPRIGHT VACUUMS. Save These Instructions
Owner s Manual HEAVY DUTY UPRIGHT VACUUMS CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T Save These Instructions Index Important Safety Instructions.... 2 Polarization Instructions....3 Grounding Instructions.....
More informationHorizontal Bottle Cooler Installation and Operation Manual
Speeds Up the Pace of Innovation Horizontal Bottle Cooler Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment! TBC-50SD, 50SB/ TBC-95SD,
More informationMAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE
Wall Heater Fan MODEL #: 2275 This fan is a CSA approved component compatible with these Williams wall heaters only: 1076512.9 2076512.9 3076512.9 1276512 1876512 3076512 1076511.9 2076511.9 IMPORTANT
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4 Replacement Element Installation 5 Replacement Parts 5 Heater Coverage Areas 6 General Notes 6 Maintenance
More informationRK / RK Methane Detector Operator s Manual
61-1006RK / 61-0192RK Methane Detector Operator s Manual Part Number: 71-0228RK Revision: 0 Released: 10/29/18 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationOwner & Operator Manual
Owner & Operator Manual NOTE: FOR ULTIMATE SAFETY AND PERFORMANCE, THIS MANUAL MUST BE READ BY INSTALLATION, OPERATING AND HAULER PERSONNEL, PRIOR TO USE OF EQUIPMENT. 23 Craig Street, Unit #6 Brantford
More informationWarnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6
TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions 4-5 Replacement Element Installation 5 Replacement Parts 5-6 Heater Coverage Areas 6 General Notes 6
More informationNilfisk Model VHS255 Drum Top Vacuum
Instructions/Spare Parts Manual Nilfisk Model VHS255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in classified (hazardous) environments, as serious injury could result. Under
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS IMPORTANT INFORMATION Warnings 2 Installation Instructions 3 Wiring Instructions 3 Outdoor
More informationMODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com MODEL HS115-3, HS115-4 & HS115-5 WIRING
More informationFire Bowls and Fire Bowl Inserts (Automated Operation) Operating and Maintenance Instructions
Table of Contents Section 1: Gas and Electric Requirements... 1 Section 2: Installation... 2 Section 3: Burner Setup and Adjustment... 8 Burner Adjustment... 9 Section 4: Maintenance... 10 Section 5: Operation...
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS CSA Model 99000 ARL00100 Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. DANGER If you smell gas: 1. Shut off gas to the
More informationSpecifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15
TABLE OF CONTENTS Page No. Specifications 3 Bladder 5 Fire Door 7 Chimney 12 Air Supply 12 Anti-Rollout Device and Ash Auger Tube 14 Timer 15 Supply Line and Return Line Threaded Connectors 15 Low Water
More informationDR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE
DR-180 Through the Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
More informationRK/ RK Combustible Gas Detector Operator s Manual
61-1003RK/61-0190RK Combustible Gas Detector Operator s Manual Part Number: 71-0120RK Revision: 0 Released: 2/11/11 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationASSEMBLY INSTRUCTIONS
ASSEMBLY INSTRUCTIONS Installer: Leave these instructions with consumer. Consumer: Keep these instructions for future reference. CSA Model99000 BRH01000 DANGER If you smell gas: 1. Shut off gas to the
More informationRetrofit Instructions for Tower Dryer Moisture Sampler Blower Kit
Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Installation Manual PNEG-1982 Date: 03-26-15 PNEG-1982 2 PNEG-1982 Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit Table
More informationHardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers
Hardwired Model Shown Installation & Operation Manual for WarmlyYours Infinity Towel Warmers Thank you for choosing your finely crafted WarmlyYours Towel Warmer. Now you can add luxury and comfort to your
More information1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090
**WARNING: READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USE. www.dellaproductsusa.com 909. 344. 2588 1500W STOVE HEATER INSTRUCTION MANUAL Item No: 050-HA-50090 Thank you for choosing a DELLA Infrared
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: PT-18W-DDF-A, PT-20F-DDF-A, PT-20S-DDF, PT-24O-DDF, PT-24-DDF, PT-24-DDF-F, PT-30-DDF, PT-30P-DDF-A, PT-30P-DDF-AF READ AND SAVE THESE INSTRUCTIONS
More informationITEM # SAIL STREAM CEILING FAN MODEL #41695
ITEM #1133114 SAIL STREAM CEILING FAN MODEL #41695 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 18 ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing
More informationIMpORTANT SAFETy INSTRUcTIONS
Table of contents SAFETy SETUp OpERATION MAINTENANcE Safety... 2 Specifications... 4 Setup... 4 Operating Instructions... 6 WARNING SyMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Diagram... 11
More informationHumidistat-Thermostat
Humidistat-Thermostat Model # HF _- - - Owner s Manual PNEG-236 Date: 12-02-09 PNEG-236 2 PNEG-236 Humidistat-Thermostat Table of Contents Contents Chapter 1 Safety... 4 Safety Guidelines... 4 Humidistat-Thermostat
More informationInstallation & Operation Manual for WarmlyYours Riviera Towel Warmers
Installation & Operation Manual for WarmlyYours Riviera Towel Warmers Thank you for choosing your finely crafted WarmlyYours Towel Warmer. Now you can add luxury and comfort to your bathroom with the soothing
More informationHR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International
HR1-08R-21 Reflective Heater Operating Instructions 3077997 Model No. HR1-08R-21 2007 Soleus Air International Thank you for choosing a Soleus Air personal heater. This owner s manual will provide you
More informationPhone (516) Fax (516) web site
PO Box 7084 Wantagh NY 11793-2204 Phone (516) 221-4762 Fax (516) 409-6631 web site www.oilstoragesolutions.com 3 Tank Tub - Product Description and Government listings 4 Tank Tub - Product Dimensions 5-6
More informationProfessional Warming Drawer and Warming Drawer Cabinet
Professional Warming Drawer and Warming Drawer Cabinet Care & Use/Installation Instructions Models: (C)VQEWD5300SS (C)VQEWD5420SS IMPORTANT SAFETY INSTRUCTIONS WARNING: Read this manual carefully and completely
More informationInstallation and Maintenance Instructions
Installation and Maintenance Instructions AMERIVENT GAS RELINING KITS MODEL AFL This symbol on the product means the product is listed by Underwriters Laboratories, Inc. GENERAL INSTALLATION GUIDELINES
More informationFIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.
RGA 2-72 INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
More informationOPERATION, SERVICE & PARTS MANUAL
OPERATION, SERVICE & PARTS MANUAL BROASTER 620N & 621 EASY BREADER Be sure ALL installers read, understand, and have access to this manual at all times. MODEL 620N MODEL 621 Genuine Broaster Chicken, Broasted,
More informationOCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters
1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING
More informationRK-05 Combustible Gas Transmitter Operator s Manual
65-2405RK-05 Combustible Gas Transmitter Operator s Manual Part Number: 71-0180RK Revision: 0 Released: 2/16/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction
More informationMariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.
MariGlo LED 45 / 60 / 90 / 120 Inspiring Excellence in Fish Keeping! Instruction version: 01/10/2013 Important Safeguards To guard against injury, basic safety precautions should be observed, including
More informationTox-COMB/ANA Combustible Gas Transmitter Operator s Manual
Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual Part Number: 71-0132TA Revision: A Released: 4/23/10 www.toxalert.com Product Warranty Toxalert International, Inc. warrants gas alarm equipment
More informationCARBON MONOXIDE HAZARD. This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you.
Intrigue EZ User manual for Intrigue EZ decorative gas appliance CAUTION DO NOT DISCARD THIS MANUAL Important operating and maintenance instructions included. Read, understand, and follow these instructions
More informationIndustrial Vacuums, Inc
Instructions/Spare Parts Manual Nilfisk Model GWD255 Drum Top Vacuum CAUTION: This Nilfisk vacuum cleaner is not to be used in explosion-hazardous areas, as serious injury could result. Under no circumstances
More informationMAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.
Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase
More informationTurbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT
Turbo Air Speed up the Pace of Innovation CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT Underbar Equipment Back Bars Installation and Operation Manual Please read this manual completely
More information150 WATT PORTABLE CLAMP LIGHT 35149
150 WATT PORTABLE CLAMP LIGHT 35149 ASSEMBLY & OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web Site at www.harborfreight.com Copyright 2006 by Harbor Freight Tools. All
More informationBuilt-in Gas Hob. Important - Please read these instructions fully before using. Operating Instructions -Please keep for future reference
Built-in Gas Hob Operating Instructions -Please keep for future reference A70GCIS Important - Please read these instructions fully before using These instructions contain important information which will
More informationRK-05 Carbon Monoxide Detector Operator s Manual
65-2433RK-05 Carbon Monoxide Detector Operator s Manual Part Number: 71-0189RK Revision: 0 Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationWALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL
WALL MOUNT ELECTRIC FIREPLACE EF-BLT13-36 EF-BLT13-42 EF-BLT13-50 EF-BLT13-60 OWNERS MANUAL NO VENTILATION REQUIRED PRODUCES SAFE AND EFFICIENT HEAT PLEASE READ THIS ENTIRE MANUAL BEFORE USING UNIT 120-VOLT
More informationUser s Manual and Operating Instructions. Model #: HH-70-SS. CONSUMER: Retain this manual for future reference.
User s Manual and Operating Instructions Model #: HH-70-SS CONSUMER: Retain this manual for future reference. IMPORTANT: Read and understand all of the directions in this manual before assembling, starting,
More informationInstruction Manual. AcuRite Atlas Outdoor Device model 06059
Instruction Manual AcuRite Atlas Outdoor Device model 06059 How It Works Set Up Your AcuRite Atlas AcuRite Atlas is an environmental monitoring station that delivers key information on current outdoor
More informationINSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER
INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS Warnings 2 Installation Instructions 3 Wiring Instructions 3 Mounting Instructions
More informationMODEL SC-600-SM OWNERS / OPERATIONS MANUAL
MODEL SC-600-SM OWNERS / OPERATIONS MANUAL 5003 Meadowland Pky. - MARION, ILLINOIS 62959 PHONE: 618-997-9348 FAX: 618-993-5960 SALES: 800-851-8180 www.southern-pride.com sales@sopride.com service@sopride.com
More informationOwner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
More informationUSER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES
USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION
More informationInfrared quartz heater
Infrared quartz heater User manual English...2 USA Introduction Infrared quartz heater Introduction Congratulations! You have made an excellent choice with the purchase of this quality Easy Home product.
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution
More informationRK-02 Multi Point Detector Operator s Manual
65-2485RK-02 Multi Point Detector Operator s Manual Part Number: 71-0237RK Revision: A Released: 11/26/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationPrime Chiller 1/10th HP Chiller
Prime Chiller 1/10th HP Chiller Instructions for Model# 2635 Warning and Safety Instructions... Page 2 Chiller Installation... Page 3 Programming Thermostat... Page 4 Warranty... Page 5 EMAIL:INFO@CURRENT-USA.COM
More informationOWNERS MANUAL MODEL 451 (-101 & -201)
OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents
More informationRegister at
Form No. 72-875 Rev A Rake and Vac, Super, and Ultra Blower/Vacuum Model No. 51574 Serial No. 12000001 and Up Model No. 51602 Serial No. 12000001 and Up Model No. 51609 Serial No. 12000001 and Up Register
More informationCompact Equipment Warranty Policy
006 07.15 Compact Equipment Warranty Policy 07/2015 Table of Contents Preface Page 1 Distributor s Warranty Responsibilities Page 1 Standard Warranties Page 2 Warranty Coverage Page 2 Warranty Limitations
More informationALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
More informationRK-03 Hydrogen Detector Operator s Manual
61-1001RK-03 Hydrogen Detector Operator s Manual Part Number: 71-0371 Revision: P1 Released: 5/26/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating detector.
More information