INSTALLATION INSTRUCTIONS FOR MODEL B512GZ SW57.6

Size: px
Start display at page:

Download "INSTALLATION INSTRUCTIONS FOR MODEL B512GZ SW57.6"

Transcription

1 ISTALLATIO ISTRUCTIOS FOR MODL B51GZ SW57.6 Page 1 The B51GZ is a two part Temperature Control system, comprising a Wall Control Pad with Integral sensor and a Relay Module. Location of Wall Control Pad. Fix to a flat surface on an internal wall approximately 1500mm above floor level at a location to sense average room temperature. Avoid locations in direct sunlight or sources of hot or cold drafts directly on or near the Wall Control sensing element. The same location guide should be observed for additional sensors. Rear View of Wall Control. Front View of Mounting Plate ITGRAL SS 6 HAT PUMP 5 BOTH ZOS 4 ZOS COT FA 1 SPD FA 1 O S 1 S RMOT SS 1 COOL/LC IDIVIDUAL ZO ZOS AUTO/COT FA MO SPD FA Remove Wall Control from Mounting Plate by inserting a flat blade screw driver into the slot at the bottom and turn as shown. Typical Plasterboard Mounting Bracket 1/4 Turn 1/4 Turn Fix mounting plate to plasterboard Clip in at Top AM 1 ST FILTR PM O TUS SU MO WD THURS FRI SAT O Install Wall Control to Mounting Plate AM Control button layout.0 ST BACK VT 1 PM oc TIM 1 CLOCK O MO TU WD THUR FRI SAT SU TIMR FILTR O COT AUTO HAT COOL COT AUTO HAT COOL RU STAG ROOM Time clock and program Menu buttons FA AUTO COTROL HAT COOL ST TMP XIT DISPLAY RPAT OMIT RSTOR TIMR Zones shown. Blank label also supplied for on Zone systems 1 LIVIG KITCH DIIG 4 BDROOM Press and snap in at Bottom FOR LASAM SRVIC SUPPORT. FR normal office hours. IDX Wall Control Pad Operating Buttons Time clock set up After hours Timer or Countdown Timer set up. Temperature setback set up. Temperature set point range limit. Filter light. MISSIOIG and SRVIC KYS. Reset controller to factory default settings. High resolution temperature reading. Room and set point temperature differentials. Cancel timers. LD check. TMPRATUR SWITCHIG DIFFRTIAL MU. Change factory settings FUTIO MU, F1-F11 and FUTIO MU IFORMATIO. Change factory settings. g : To add and assign ZOS see F5. AIR CODITIOIG OPRATIG SLCTIO. TS. Use in conjunction with wiring diagrams and Function Menu WIRIG DIAGRAMS Page /6 DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

2 Wall Control Pad operating buttons. Page O/ button. Press to start or stop system manually or activate optional After Hours Run Time. FA COTROL button. Select fan speed and operating mode. Function Menu and Wall Control DIP switch for other options Repeat pressing of button to select the required fan speed in continuous or automatic operating mode. Automatic mode (COT light off). cycles with heating or cooling demand. Continuous mode (COT light on). runs continuously when system is on. Air circulation mode. Turn system off. Press FA COTROL button. To stop fan Press O/. AUTO/HAT/COOL button. Select temperature operating mode. Repeat pressing of button to select operating mode. AUTO MOD. AUTO light. Heat or Cool automatically selected on system demand. HAT MOD. HAT light. System operates in heating cycle only. COOL MOD. COOL light. System operates in cooling cycle only. DISPLAY button. Select screen display. Repeat pressing of button to display the following: TMPRATUR ST POIT. ST light. TIM. Time and day displayed. ROOM TMPRATUR. ROOM light. ST TMP Up and Down arrow. Adjust room temperature set point. Press UP or DOW arrow to select temperature set point. To change factory adjustment range. Temperature Set Point Range Limit (page). Zone buttons. If applicable Press Zone button to open. Zone light on. Press Zone button to close. Zone light off. ote: e zone is always activated to prevent air conditioning system operating with all zones closed. Time Clock program buttons. Turn off system to set up time clock Turn time clock. Press DISPLAY button to read Time. Press button twice. TIM CLOCK light on. light flashing. Press O/ button. O light flashing. Press to accept. Time displayed and Hours flashing. Press Up or Down arrows to set hours. Press Minutes flashing. Press Up or Down arrow to set minutes. Press to accept. Day flashing. Press Up or Down arrow to set day Press to accept. to accept. Monday VT 1 O displayed. Press Up or Down arrow to set the time. Press to accept. Monday VT 1 displayed. Press Up or Down arrow to set the Off time. Press to accept. Monday VT O displayed. Press Up or Down arrow to set the time. Press to accept Monday VT displayed. Press Up or Down arrow to set the Off time. Press to accept. Tuesday VT 1 O displayed. Repeat as above. Alternatively to repeat previous day program from Tuesday onwards. Press RPAT button then for each /Off event for that day. At VT 1 O, repeat for the following days. Individual /Off event times can be programmed for each day..g different Off time on Thursday. OMIT To omit an vent..g VT O Saturday and Sunday press. Three dashes will be displayed. RSTOR otes. 1. To restore an vent press RSTOR OMIT. The Time will be displayed.. To exit menu at anytime press XIT button.. To turn time clock operation off. Press button twice. O flashing. Press O/ button. flashing. Press XIT button. TIMR Button. Set timer as a) Countdown timer (factory setting) or b) After Hour Run Timer. a) Countdown timer. Setting timer to override time clock function. Set timer to start air conditioning system. Press TIMR button. Time and day shown with TIMR and O light flashing. Press Up or Down arrow to select time. Press button to accept. TIMR light on. S et timer to stop air conditioning system. Press TIMR button. Time and day shown with TIMR and light flashing. Press Up or Down arrow to select off time. Press button to accept.timr light on. otes. 1. To cancel the TIMR set up. Press the O/ button. TIMR light off.. To see the set time to start or stop the system, press TIMR button. Time is shown on display.. b) After Hour Run Timer. To run A/C system for preset time(adjustable) out of normal operating time. otes: 1. Time clock function has to be enabled for AH run on timer function to operate... Set AH run timer function and run time from Function Menu F9 and F10. ote F8 must also be in A1 setting.. Press Wall Control O button or optional remote O button(see wiring diagrams) to enable AH Timer. TIMR light 4. To turn off system before completion time, Press button. 5. If AH run time setting overlaps time clock start time the system starts but TIMR light will be Off. DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

3 Wall Control Pad operating buttons. Continued Page Temperature setback. (conomy temperature setting). Turn off system to set up. Generally used in unoccupied times or during the night to limit the maximum or minimum room temperature. Press DISPLAY button until room temperature is displayed. ROOM light. Press button. ST BACK light. light flashing if setback is disabled. Press ST TMP Up arrow to select STBACK operating mode (COOL, HAT, COOL and HAT or ). STBACK COOL mode only. COOL, O lights flashing. STBACK HAT mode only. HAT, O lights flashing. STBACK COOL and HAT mode. COOL, HAT, O lights flashing. Press to accept selection. Current cooling setback temperature displayed. COOL and O lights flashing. Press ST TMP Up or Down arrow to select cooling setback temperature. Press to accept. Current heating setback temperature displayed. HAT and O lights flashing. Press ST TMP Up or Down arrow to select heating setback temperature. Press to accept. Press XIT to exit menu. ote. COOL mode. Operates in cooling only. Cooling setback range 4oC to 6oC. HAT mode. Operates in heating only. Heating setback range 8oC to 0oC. COOL and HAT mode. Operates in cooling and heating. Temperature Set Point Range Limit. Turn off system to change settings. To change UPPR LIMIT Press DISPLAY button to display TIM and day. Press button then timeclock program Up arrow. Current setting will be displayed..g U8 (8oC). Press the ST TMP Up or Down arrow within 0.5 seconds to adjust set point upper limit. The system will automatically except the new settings. ote. Maximum set point limit is 6oC. To change R LIMIT. Press DISPLAY button to display TIM and day. Press button then timeclock program Down arrow. Current setting will be displayed..g L16 (16oC). Press and ST TMP Up or Down arrow within 0.5 seconds to adjust set point lower limit. The system will automatically except the new settings. ote. Minimum set point limit is 10oC. Filter light. Filter light operates every 160 running hours to remind owners to check air filter. Reset filter light by pressing O/ button. ote. Filter light is a reminder only and is not indicating a fault. To read Set point when screen is displaying time or room temperature. Quick press of ST TMP Up or Down arrow to display set point. To change set point, press and hold Up or Down arrow. MISSIOIG and SRVIC KYS Reset controller to factory default settings. With the system. Press and hold XIT button, press and release Down arrow. Press O/ button and release with XIT button. All LD s will display if successful. High resolution temperature reading. Displays sensor temperature to 1/10 degree. Press and hold XIT, press RPAT, release both. Press DISPLAY to exit menu. Room temperature and set point temperature differential. Press and hold XIT, press OMIT, release both. Press DISPLAY to exit menu. RSTOR Cancel timers. Press and hold XIT, press O/, release both. LD check. Turn off system to check. Press and hold XIT, press DISPLAY, release both. DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

4 TMPRATUR SWITCHIG DIFFRTIAL MU. Turn system to change settings. Page 4 Press and hold XIT button. Press UP arrow. Release both buttons. STAG 1, COOL and lights. Press UP or DOW arrow to change setting. Press button to accept change and move to next stage. STAG 1, COOL and O lights. Repeat for other settings. Table Below. To exit from menu at any time press XIT button. F1 F F F4 F5 Heating and Cooling Stage1 Cool Off Stage1 Cool Stage Cool Off Stage Cool Stage Cool Off Stage Cool FUTIO MU. Turn system to change settings. Press and hold XIT button press button. Release both buttons. nters Function Menu F1 (Function 1). Press the Up or Down arrow to change setting. Press button to except your choice and move to F (Function ). Repeat for all functions. ote. To exit menu at any time press XIT button. FUTIO MU IFORMATIO. F1. Automatic-ly temperature changeover or Customer-Select temperature operation from Wall Control. F. Runon. Recommended when using electric heating. F. Compressor start delay. Anti-cycle protection F4. Condenser Pump Interlock. nter menu to enable function. F5. Add Zones and assign zones to optional sensors. Sensor 1 has been factory assigned to Zone 1. Optional Sensor has been factory assigned to Zone. Zone or Zone 4 can be assigned(set to sense temperature )to either Sensor 1 or optional Sensor. F6. Sensor 1 calibration offset. F7. Sensor calibration offset. F8. Auxiliary input functions. Four available external input functions. notes in Function Table. F9. Turn After Hours run timer function. ote: Time clock program has to be enabled for After Hours to operate. F10 Set After Hours run time period. F11 Filter. Time remaining before indication. Factory Default Cool/ Auto/Heat P1-1 Adjustment Range 0-10Mins 0-10Mins Factory Settings 0.5oC 1.0oC 1.0oC 1.5oC 1.5oC.0oC Options or Increments Auto All settings are the temperature offset from the Controller set point. Lights (LD S) Displayed on Wall Controller O. Temperature Adjustment 0.0 to 9.0oC 0.1 to 9.9oC 0.0 to 9.0oC 0.1 to 9.9oC 0.0 to 9.0oC 0.1 to 9.9oC COOL Lights (LD s) Displayed on Wall Control 1 FILTR ROOM COOL HAT AUTO C ST TIM TIMR O RU HAT Stage1 Heat Off -0.5oC -0.0 to 9.0oC Stage1 Heat -1.0oC -0.1 to 9.9oC Stage Heat Off -1.0oC -0.0 to 9.0oC Stage Heat -1.5oC -0.1 to 9.9oC Stage Heat Off -1.5oC -0.0 to 9.0oC Stage Heat -.0oC -0.1 to 9.9oC B. -stages of heating and cooling only available without zones control. DIP switch Off. settings page 5 Press Zone button or 4 to add to system. Press Up or Down arrow to assign Zone or 4 to Sensor 1 or optional sensor. F to.5 0.1oC F to.5 0.1oC F8 A1 A,A,A4 A1. Time switch. Open contact stops A/C. Closed contact starts A/C. Wall Control can override time switch function. A. Standby. Open contact stops A/C. Closed contact starts A/C at last setting. Wall Control cannot override function. A. Start. Contact momentary closed starts A/C. Wall Control can override this function. A4. Key card. Open contact stops A/C. Wall Control cannot override function. Closed contact, A/C can be restarted from Wall Control. F9 F Mins 0-600Mins 15 Mins o adjustment. F Hours Indicates time remaining 1 O ST STAG DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

5 AIR CODITIOIG OPRATIG SLCTIO. Set DIP switch settings on rear Wall Control Pad. Wall Control onboard sensor used. Heat Pump or reverse cycle A/C system. Control Individual or all the Zones When zone control is required operates continuously when system. Single fan speed only. Connect to relay O Integral sensor Heat Pump Both Zones Zones Continuous 1 Speed DS.6 DS.5 DS.4 DS. DS. DS.1 Remote sensor 1 Cool/lectric Individual Zones Two zone. I.e Day or ight not both. o Zones When stage heat or cool is required Page 5 Auto/Cont Allows fan operating mode from Wall Control Pad. Speed Wall Control onboard sensor not used Comp/Cooling valve - lectric Heat/ Heating valve Allows fan speed selection from Wall Control Pad TS. wiring diagrams for ote o. and FUTIO MU for additional information volt Control System. Connect 4vac into terminals instead of 40 volts.. Single Speed. Use fan relay terminal.. Zone Dampers. Use 40 vac Drive Open, Drive Close or Drive Open, Spring Close Actuators. 4. xternal stop/start input by others. Function Menu. F8 in A1 setting and F9 to be Off. 5. Remote after hours run momentary push button. Function Menu. F8 in A1 setting and F9 to be set. 6. System O indication. Max 4vac supplied by others. Function Menu F4 Off. o indication if system in ventilation mode. 7. Pump Interlock with LASAM P.I.R.M or differential water pressure switch. nable Function Menu F4. 8. System O indication. Use ZO 4, 40 vac output. Wall Control DIP switch. Zone 4 not enabled in F5. 9. Two Sensors in circuit. Temperature readings from sensors are averaged. 10. Remote Sensor 1. Remote used instead of Wall Control Sensor. Wall Control DIP switch 6 Off. TYPICAL WIRIG COCTIOS. following diagrams for other Systems +1 RLAY MODUL ote VRIFY FA eut WALL COTROL KY ote 1 SS 1 MO SS 1 SHILD SSOR To compressor STG COOL To compressor 1 STG 1 COOL 40 volt control UTRAL ote 1 ITRAL LIKS RV COOL RV HAT STG HAT ZO 4 ZO ZO ZO 1 To 4 way valve (s) operating in cooling To 4 way valve (s) operating in heating Z4 Z ote Z Z1 SS 1 MO Compressor - speed fan. 1 stage R/C heat 4 zone control SHILD 40 vac System 1 System +1 RLAY MODUL +1 RLAY MODUL VRIFY VRIFY S KY ote 9 KY SS 1 RV COOL SS 1 SS 1 RV COOL SSOR RV HAT SSOR Valve RV HAT STG HAT MO STG HAT eutral SHILD STG COOL Compressor STG COOL STG 1 COOL ZO 4 Zone 4 Compressor 1 STG 1 COOL ZO 4 Zone ZO ZO 40 vac eutral UTRAL ZO UTRAL Zone - speed fan. ZO stage R/C heat ZO 1 Zone 1 4 zone control ZO 1 Remote Sensor Valves eutral Zone 4 Zone eutral Zone Zone 1 DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

6 TYPICAL WIRIG DIAGRAMS ote 4 ote 9 Remote start/stop. S S1 SS 1 MO SHILD Compressor Compressor 1 - speed fan. - stage R/C heat Remote O/ Remote Sensors 4 Zone control 40 vac Pump verification with Leasam Pump Interlock System. ote 7 System System 4 +1 RLAY MODUL +1 RLAY MODUL VRIFY VRIFY KY KY SS 1 RV COOL SS 1 SS 1 RV COOL SSOR RV HAT SSOR Valves RV HAT MO STG HAT STG HAT eutral SHILD STG COOL Compressor STG COOL STG 1 COOL ZO 4 Zone 4 Compressor 1 STG 1 COOL ZO 4 Zone ZO ZO 40 vac eutral UTRAL ZO UTRAL Zone ZO ZO 1 Zone 1 - stage R/C heat ZO 1 Pump Interlock Page 6 Valves Compressor System O Relay. Max supply 4vac ote 6. ote 10 S1 SS 1 MO Compressor Compressor 1 - stage cool - stage electric heat Remote Sensor 1 System O relay. SHILD 40 vac Pump verification with SFS-1 System 5 pressure switch ote 7 System 6 +1 RLAY MODUL +1 RLAY MODUL VRIFY VRIFY KY KY SS 1 RV COOL SS 1 SS 1 RV COOL SSOR RV HAT SSOR RV HAT Stage Heat STG HAT MO STG HAT SHILD STG COOL Compressor STG COOL STG 1 COOL ZO 4 Stage Heat Compressor 1 STG 1 COOL ZO 4 ZO Compressor ZO 40 vac UTRAL ZO - stage cool UTRAL ZO - stage electric heat ZO 1 Pump interlock ZO 1 System O relay. Stage Heat System O Relay. ote 8 ote 9 SS 1 MO Remote start/stop. ote 4 System 7 System 8 +1 RLAY MODUL RLAY MODUL Remote after hours run timer. +1 VRIFY VRIFY S ote 5 S1 KY KY SS 1 RV COOL SS 1 SS 1 RV COOL SSOR RV HAT SSOR RV HAT Stage Heat STG HAT MO STG HAT SHILD SHILD Compressor STG COOL STG COOL Compressor 1 STG 1 COOL ZO 4 Stage Heat STG 1 COOL ZO 4 M CH.W.V ZO Compressor ZO 40 vac 40 vac UTRAL ZO UTRAL ZO Cooling water valve ZO 1 stage electric heat ZO 1 Remote O/ - speed fan. - stage cool - stage electric heat averaging Sensors Remote O/ Stage Heat DPI-B51GZ- &O. SUBJCT TO CHAG WITHOUT TIC. -5-6

T-32-TS Touchscreen Thermostat. Installation Manual

T-32-TS Touchscreen Thermostat. Installation Manual T-32-TS Touchscreen Thermostat Installation Manual TABLE OF CONTENTS Introduction...4 Getting Started...5 Installing the Thermostat...6, 8 Disassembly...6 Thermostat Location...6 Mounting the Subbase...6,

More information

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Smart Temp. ApolloP/n Installation Manual. Version 1.0 Smart Temp ApolloP/n 44-800 Installation Manual Version 1.0 TABLE OF CONTENTS Introduction...6 Getting started...7 Installing the thermostat...8 Disassembly...8 Thermostat location...8 Mounting the subbase...8,

More information

Product Manual SZ1009

Product Manual SZ1009 Product Manual SZ1009 Conventional Heating & Cooling Thermostats with Heat Pump Mode Communicating Thermostats Description The SZ1009 is a microprocessor-based mable thermostats designed for conventional

More information

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes

(-)HC-TST213UNMS 5/1/1 Day 5/2 Day Non-Programmable. Yes Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Universal Thermostat

More information

4 Wiring Brochure Wiring and

4 Wiring Brochure Wiring and - Brochure tekmarnet 4 Thermostat 544 D 544 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Comfort System T-21-P Touchscreen Thermostat Installation Manual Comfort System T-21-P Touchscreen Thermostat Installation Manual Version 1.40 INTRODUCTION The Comfort System T-21-P is a feature-rich touchscreen thermostat that can be battery powered or hardwired to

More information

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction. Introduction The UL listed Phone-A-Stat (model # 7632 ) is designed and approved for the safe operation of remotely controlling four independent loads, such as a sprinkler system or a water heater via

More information

User s Manual

User s Manual 997-060180-4e User s Manual 8403-060 Menu Driven Display 1120-445 I. CONTROLLER OPERATION ADJUSTING TEMPERATURE (Temporary Override when in Programmable mode) 1. Before you can adjust the temperature,

More information

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1. TH146-P-2H1C Installation Guide Programmable 2H1C Controller Removable Connector * Removable Connector * TH146-P User Console CT280-2H1C Control Module AC144-03 Outdoor Temperature Sensor * To remove a

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8800 Universal Communicating Thermostat Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 2 Thermostat mounting...

More information

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance Programmable Thermostats Detailed User Guide 2020NC 2220NC Single Stage Heat / Cool Conventional and Heat Pump Up to 2 Heat / 2 Cool Conventional Up to 2 Heat / 1 Cool Heat Pump Model number is located

More information

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help? INSTALLATION MANUAL This manual covers the following models: T955W Master Thermostat Base Module Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency

More information

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins Table of Contents Parts Diagram........................................................... 1 Icon Descriptions......................................................... 2 Specifications...........................................................

More information

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance Programmable Thermostats Detailed User Guide 2020NC 2220NC Single Stage Heat / Cool Conventional and Heat Pump Up to 2 Heat / 1 Cool Conventional and Heat Pump Model number is located on back of thermostat

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS - SPLIT DUCTED SYSTEMS CONGRATULATIONS on your purchase of an ActronAir air conditioning system. This energy efficient unit has been precision designed, manufactured from high quality

More information

ETN-24-HC21-PROG Econo-Vent

ETN-24-HC21-PROG Econo-Vent ETN-24-HC21-PROG Econo-Vent Owner's Manual - Installation and Operating Instructions Cat. G030121 Rev. 3.1 02.06 Meitav-tec Ltd (Contel group) Tel: 972-3-9626462 ax: 972-3-9626620 www.meitavtec.com - support@meitavtec.com

More information

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE Emerson Blue Wireless Comfort Interface - Homeowner User Guide Message to Homeowners Congratulations on choosing the Emerson Blue

More information

Product Manual SZ1022/SZ1031/SZ1035/

Product Manual SZ1022/SZ1031/SZ1035/ Product Manual SZ1022/SZ1031/SZ1035/ Conventional Heating & Cooling Thermostats Communicating Thermostats Description The SZ1022, SZ1031, and SZ1035, are microprocessorbased mable thermostats designed

More information

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats Installation and Advanced Programming Instructions HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats These instructions are intended for installation and first time set up of the thermostat. For day to day

More information

Please read this manual carefully before installation and use.

Please read this manual carefully before installation and use. Doylestown, PA 18902 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: support@scillc.com - www.scillc.com FMT-24-SUPER-PROG With freeze protection Owner s Manual Installation and Operating Instructions

More information

Installation and Programming Instructions for. Deluxe Programmable Thermostats

Installation and Programming Instructions for. Deluxe Programmable Thermostats Installation and Programming Instructions for Deluxe Programmable Thermostats TABLE OF CONTENTS INTRODUCTION...4 STANDARD FEATURES...4-6 THERMOSTAT LOCATION...7 REMOVING THE THERMOSTAT FROM THE SUBBASE...8

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T915 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux.

More information

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS Debonair 33CS Flush-Mounted Flatstat Commercial Programmable Thermostat IMPORTANT: Read entire instructions before programming the thermostat. Owner s Manual Part Number 33CS250-FS and 33CS220-FS GENERAL

More information

1F Non-Programmable 5/1/1 Day 7 Day

1F Non-Programmable 5/1/1 Day 7 Day Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION MODEL 5100 USER MANUAL Compatible with low voltage multi-stage heat/cool systems with up to two stages of heating and two stages of cooling. READ ALL INSTRUCTIONS BEFORE PROCEEDING 1 2 3 4 5 6 7 CONTENTS

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8476 Thermostat with Event-Based Air Cleaning Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Installation Installation location recommendations... 3 Outdoor

More information

MC200V3. Installation and Setting Instructions

MC200V3. Installation and Setting Instructions MC200V3 stallation and Setting structions MC200 stallation and Setting structions Issue 4.1 October 2014 Contents Section Page 1 Description 1 2 Specifications 1 3 Dimensions 2 4 stallation 2 5 lectrical

More information

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat WARNING! Important Safety Information Builder MODEL 2200 Series 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat USER MANUAL Compatible with low voltage multi stage heat/cool

More information

ETN-24-SUPER-PROG (US Program - Celsius)

ETN-24-SUPER-PROG (US Program - Celsius) Meitavtec Ltd (Contel group) Tel: 972 (3) 962 6462 Fax: 972 (3) 962 6620 www.meitavtec.com support@meitavtec.com ETN24SUPERPROG (US Program Celsius) Owner s Manual Installation and Operating Instructions

More information

WARNING Important Safety Information

WARNING Important Safety Information Premier Series Programmable Thermostats MODEL 5000 1 2 3 Specifications Installation Testing Your New Thermostat Programming User Settings WARNING Important Safety Information Additional Operation Features

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000R Part No. 4028407 Dehumidifier & Ventilation System Controller 4201 Lien Road, Madison, WI 53704 TOLL-FREE (800)-533-7533

More information

Smart Temp. Model

Smart Temp. Model Smart Temp Model 42-160 SINGLE STAGE PROGRAMMABLE THERMOSTAT 1 Heat / 1 Cool Single Stage Thermostat. 5+2 Programmable, Compatible with Gas Heat & Heat Pump System Installation and Operation Manual SPECIFICATIONS:--------------------------------------------------------------------------------

More information

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer INTRODUCTI Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer technology to provide precise time/temperature control. This

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 5100 Premier Series 7-Day Programmable 2-Heat / 2-Cool Heat /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage multi-stage heat / cool systems with up to two stages of heating and two stages

More information

HEAT COOL. Meets Commercial California Title 24

HEAT COOL. Meets Commercial California Title 24 Digital Thermostat commercial THERMOSTAT T2900 7-DAY MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Control up to 3 Heat & 2 Cool Stages 3 Configurable Outputs Adjustable 2nd & 3rd Stage Timers & Deadbands

More information

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS

More information

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652C 8400 Tstat Install.indd 1 10/13/09 11:08:56 AM Table of contents Installation Installation location

More information

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions - Brochure tekmarnet 4 Thermostat 542 D 542 06/05 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough In Wiring Rough-in 4 Wiring

More information

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button. Operation GT7000 Operation GT7000 TEMP UP button Time / Current Temp Display - Cover Closed - Control Panel SET CLOCK SDP HOME DAY PROGRAM TIME SLOT TIME SET TIME NEXT P TIME COPY HOLD REVIEW FILTER TEMP

More information

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button USER MANUAL Type UCG/UDG 57116D 06/12 (MBC) 1.10 2012 OJ Electronics A/S...1 Français...7 Español... 14 Type UCG/UDG Contents Introduction...1 First Time Settings...1 Ground Fault Circuit Interrupter (GFCI)...1

More information

Digital Programmable

Digital Programmable www.geappliances.com Digital Programmable Thermostats Operating Instructions Auto Changeover..........10 Day/Time Setting Mode.....6 Default Mode...............4 Fan Control...............10 Hold and Temporary

More information

RDY2000 Commercial Room Thermostat

RDY2000 Commercial Room Thermostat Document No. 9-95 June 4, 4 RDY Commercial Room Thermostat Figure. RDY Thermostat. Product Specifications System Compatibility Conventional Up to Heating/ Cooling stages Heat Pumps Up to 4 Heating/ Cooling

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T725 Thermostat Applications Guide Des cription Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS

DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS DX2002 OPERATING AND PROGRAMMING INSTRUCTIONS The four pushbuttons located at the bottom right of the circuit board are used to do all programming. Each button has more than one function. Alternate Settings

More information

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control O M N I S T A T ELECTRONIC COMMUNICATING THERMOSTAT Installation Manual RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control Document Number 13I00-5 November, 1997 CONTENTS

More information

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page. INSTALLATION MANUAL This manual covers the following models: T755 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

DAY/TIME Button: Selects hour, minute and day setting.

DAY/TIME Button: Selects hour, minute and day setting. MODEL 5300 USER MANUAL READ ALL INSTRUCTIONS BEFORE PROCEEDING For more information on energy savings, go to www.energystar.gov Premier Series Universal Auto Changeover Thermostat Up to 2 Heat / 2 Cool

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

Safety & Installation Instructions

Safety & Installation Instructions 8400 Series Thermostats Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS 61000652A 8400 Tstat Install.indd 1 7/23/09 2:20:45 PM Table of contents Installation Installation location recommendations...

More information

USER'S OPERATING INSTRUCTIONS

USER'S OPERATING INSTRUCTIONS SAT-2 Thermostat COOL FAN DRY HEAT AUTO SLEEP SWING AUTO ZONE SUN MON TUE WED THU FRI SAT HEATER ON OFF ERR UNIT USER'S OPERATING INSTRUCTIONS CONTENTS Page Introduction 3 Features Summary 3 Display 4

More information

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 ERV-24 Technician Settings & Operating Manual Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135 1 Introduction brief description General The ERV-24-HC11

More information

Installation and Setting Instructions

Installation and Setting Instructions stallation and Setting structions MC200 stallation and Setting structions Issue 2.1 January 2010 Contents Section Page 1 Description 1 2 Specifications 1 3 Dimensions 2 4 stallation 2 5 lectrical Connections

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 3006 Auto Changeover 7-Day Programmable Hardwired Programmable Electronic Thermostat 7-Day Programmable Single Stage Heat Pump/Non-Heat Pump Systems Backlit Display Single Stage Heat/Cool Systems Field

More information

- Data Brochure tekmarnet 4 Thermostat 542e

- Data Brochure tekmarnet 4 Thermostat 542e - Data Brochure tekmarnet 4 Thermostat 542e D 542e 03/08 1 Information Brochure Choose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

Programmable Thermostat

Programmable Thermostat Programmable Thermostat with Humidity Control Auto Changeover Dual Power 7-Day, 5-2-Day, or 5-1-1- Day Programmable Configurable for Multiple Systems Large Display with Backlight Selectable Fahrenheit

More information

RCS Residential Control Systems Inc.

RCS Residential Control Systems Inc. RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following

More information

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE OWNER S MANUAL COMMERCIAL THERMOSTAT P/N P374-2800 I 2 : 0 0 Su AUTO Pm 74 COOL 7 2 HEAT T O T A L I N E HEAT COOL 7-DAY HEAT PUMP PROGRAMMABLE DIGITAL THERMOSTAT 3 Configurable Outputs Control up to 2

More information

ComfortSense 7500 Commercial Thermostat. User Guide

ComfortSense 7500 Commercial Thermostat. User Guide ComfortSense 7500 Commercial Thermostat User Guide 507505-02 6/2018 Supersedes 5/2017 Table of Contents Features...2 Home Screen Temperature Indicator...2 Home Screen Information...3 Operating Mode Selection...5

More information

Commercial Touchscreen Thermostat

Commercial Touchscreen Thermostat 55,13M 1/27 Supersedes 12/25 Commercial Touchscreen Thermostat 25 Lennox Industries, Inc. Dallas, Texas, USA APPLICATION Page 1 INSTALLATION INSTRUCTIONS The Lennox Commercial Touchscreen Thermostat provides

More information

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Each reader connected to the Challenger LAN system is programmed as an Arming Station. Challenger Version 8 Readers. This document provides details of the programming requirements for adding readers to a Version 8 Challenger System for use in Alarm Control Access Control functions. Each

More information

WHITE-RODGERS COMFORT-SET 90 SERIES

WHITE-RODGERS COMFORT-SET 90 SERIES INSTALLATI DESCRIPTI WHITE-RODGERS COMFORT-SET 90 SERIES MULTI-STAGE/HEAT PUMP INSTALLATI/CFIGURATI This White-Rodgers Automatic Setback Digital Thermostat uses microcomputer technology to provide precise

More information

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL 1. INTROUCTION Zone control is a two pieces fan coil thermostat available for Heat/Cool versions. Its application is for the duct type system

More information

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS Contents T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS OWNER S GUIDE Features... 2 Settings... 3 Programming... 5 63-2638 FEATURES Typically used in buildings (including: restaurants,

More information

SC Installation, Operation & Application Guide

SC Installation, Operation & Application Guide SC 5211 2-Stage Heat Pump Auto Changeover Hardwire Programmable Electronic Thermostat 7-Day, 5-2-Day or 5-1-1-Day Programmable Configurable 2-Stage Heat Pump Systems Large Display With Backlight Selectable

More information

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT! PSP721U SMART TEMP UNIVERSAL PROGRAMMABLE THERMOSTAT FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 52033 IMPORTANT! Please read all instructions carefully before beginning

More information

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats 2007 Lennox Industries Inc. Dallas, Texas, USA OWNER S GUIDE ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats IMPORTANT Read and save these instructions. 506067 01

More information

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual COM RT SYSTEM T-32-TS Touchscreen Thermostat User Manual TABLE O CONTENTS INTRODUCTION USINGTHETOUCHSCREEN DISPLAY TYPICAL DISPLAY SETTINGTHE DAY,TIME AND CALENDAR SETTING DAYLIGHT SAVINGTIME BASIC UNCTIONS

More information

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings Energy Plannersm Programmable Thermostat Customer Guide Take control of your comfort and energy savings BLANK PLACEHOLDER FOR INSIDE FRONT COVER DO NOT PRINT Contents Introduction About this Guide... 1

More information

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat MODEL 2000NC USER MANUAL Builder Series 5-2 Day Programmable Single Stage /Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

1F Day Day Non-Programmable. Maximum Stages Heat/Cool Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. Blue Humidity

More information

Installation, Service, and Troubleshooting Instructions

Installation, Service, and Troubleshooting Instructions 33CS TEMP System Unitary Controller Thermostat Installation, Service, and Troubleshooting Instructions Page GENERAL........................................ 2 TEMP System Components......................

More information

1F80ST /2 Day 5/1/1 Day Non-Programmable 1F86ST-0471

1F80ST /2 Day 5/1/1 Day Non-Programmable 1F86ST-0471 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. 80 Series Thermostat

More information

MC200/V3 Control System

MC200/V3 Control System Issue 5.0 April 2016 MC200/V3 Control System dustrial & Commercial Heating Systems. www. p o w r m a tic. c o.uk Users, stallation and Setting structions WARIG: THIS APPIAC MUST B ARTHD IMPORTAT: Reset

More information

1F Day Day Non-Programmable. Maximum Stages Heat/Cool

1F Day Day Non-Programmable. Maximum Stages Heat/Cool Blue Universal Touchscreen Thermostat with Automatic Heat/Cool Changeover Option Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

User & Installer Manual SMT-400 Enterprise Wi-Fi Thermostat User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat Ver 1.01 May 2018 Great care has been taken in the preparation of this manual. Smart Temp Australia P/L takes no responsibility for errors

More information

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3

1F Day 5/1/1 Day Non-Programmable. W/ Economizer Max. Stage Heat/Cool 1/1 1/2 2/2 2/3 3/1 3/2 4/2 4/3 Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. APPLICATIONS

More information

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS 63-2652 FEATURES Typically used in buildings (including: restaurants, shopping malls, office buildings and banks) under 55,000 square feet.

More information

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

SAS908WHB-3-RF/B WIRELESS THERMOSTAT SAS908WHB-3-RF/B WIRELESS THERMOSTAT Installation and operation instructions 908WHB-3-RF/B can replace most common residential thermostat and is designed to be used with electric, gas or oil heating control

More information

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation

FMT24-SUPER-2S-FP-PROG-F Owner s manual & Technician Settings. Installation Installation The FMT24-SUPER-2S-FP-PROG is designed for flush mounting in the room to be controlled. It should be located where the occupant can easily read the LCD display and use the controls. If the

More information

T600MEP-2 Programmable Economizer Thermostat

T600MEP-2 Programmable Economizer Thermostat Installation Instructions Issue Date January 19, 2005 T600MEP-2 Programmable Economizer Thermostat Application The T600MEP-2 is a programmable thermostat for control of single- or two-stage unitary rooftop

More information

SMART 2000 Digital Programmable Thermostat Installation Manual Robertshaw 2/

SMART 2000 Digital Programmable Thermostat Installation Manual Robertshaw 2/ SMART 2000 Digital Programmable Thermostat Installation Manual www.robertshaw.com 2015 Robertshaw 2/15 352-00193-001 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD Turn off power at the

More information

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat Models: VS30W and VS30B it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014 10:28 Digital Thermostat Models: VS30W and VS30B INSTALLER / USER MANUAL it600 VS30W - VS30B Installer - User Manual 015_Layout 1 28.07.2014

More information

ATC32U03 igate Communicating, Programmable Thermostat

ATC32U03 igate Communicating, Programmable Thermostat ATC32U03 igate Communicating, Programmable Thermostat User Manual 97B0055N02 Rev.: 11/3/17 Table of Contents Section Title Page Menu Navigation Shortcuts 3 1.0 Operating Mode Selection 3 2.0 Temperature

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Part No. 4028539 Dehumidifier & Ventilation System Controller 4201 Lien Rd Madison, WI 53704 TOLL-FREE 1-800-533-7533 www.thermastor.com

More information

ATC32U01 igate Communicating, Programmable Thermostat

ATC32U01 igate Communicating, Programmable Thermostat ATC32U01 igate Communicating, Programmable Thermostat User Manual 97B0055N02 Rev.: 7/2/12 Table of Contents Section Title Page Menu Navigation Shortcuts 3 1.0 Operating Mode Selection 3 2.0 Temperature

More information

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide. INSTALLATION MANUAL This manual covers TopTech models: TT-N-721 and T721 Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump ( Aux. or Emergency Heat) Heat Pump (with Aux.

More information

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series Premier Series MODEL 5000 USER MANUAL 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including

More information

HEAT PUMP PROGRAMMABLE THERMOSTAT

HEAT PUMP PROGRAMMABLE THERMOSTAT HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15

More information

DP711. PurePro DP711 INSTALLATION AND OPERATING INSTRUCTIONS

DP711. PurePro DP711 INSTALLATION AND OPERATING INSTRUCTIONS DP711 PurePro DP711 INSTALLATION AND OPERATING INSTRUCTIONS 52178 1 COMPATIBILITY........................................ 2 2 FEATURES.............................................. 2 3 ELECTRICAL RATINGS.................................

More information

Underfloor Heating Programmable Thermostat

Underfloor Heating Programmable Thermostat Underfloor Heating Programmable Thermostat t: 093 4906 m: 0794 69635 w: www.gs-ufh.co.uk e: gs@warmfloors.co.uk POWER CLOCK H A DOWN UP TO CHANGE THE TIMINGS AT ANY STAGE DURING THE PROCESS YOU CAN PRESS

More information

PerFormance Pro t12000 series InstallatIon GUIDe

PerFormance Pro t12000 series InstallatIon GUIDe PerFormance Pro t12000 series InstallatIon GUIDe the Peco PerFormance Pro thermostat Thank you for choosing a PCO Performance PRO thermostat. The Performance PRO T12000 Series is intended for use in residential

More information

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT CONTENTS Installation Instructions for Heating & Air Conditioning 1F72 5/2 Day Programmable Heat Pump Thermostat Preparations... 1 Thermostat Details... 1 Removing Old Thermostat... 1-2 Mounting and Wiring...

More information

OWNER S MANUAL Venstar Inc. 08/07

OWNER S MANUAL Venstar Inc. 08/07 Digital Thermostat commercial SCHOOL THERMOSTAT T2900SCH MABLE up to 3-heat & 2-cool HEAT COOL HEAT PUMP Energy Saving Operation Morning Warm-up Period Programmable Override Unoccupied until button press

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE

More information

Elegance. SMT-700 User manual. Ver

Elegance. SMT-700 User manual. Ver Elegance SMT-700 User manual Ver 3.0. 0807 Congratulations on the purchase of your new Thermostat! Your new air conditioning system thermostat has been built using the best components and design philosophy

More information

Model: Edge-HC. 1 edge-hc

Model: Edge-HC. 1 edge-hc Model: Model: Edge-HC 1 edge-hc Table Of Contents Product Image Table of Contents Installation Procedure System Type LCD Display Power On/OFF Setting the Time & Date Mode Select Fan Speed Temperature Display

More information

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents. INSTALLATION MANUAL This manual covers TopTech models: TT-S-755H Thermostat Applications Guide Description Gas or Oil Heat Electric Furnace Heat Pump (No Aux. or Emergency Heat) Heat Pump (with Aux. or

More information

danfoss Heating Solutions 5

danfoss Heating Solutions 5 4. Technical settings...22 4.1 Deactivating automatic daylight saving time...22 4.2 Adjusting to radiator/room...23 4.3 Deactivating intelligent control...23 4.4 Technical specifications...24 5. Safety

More information

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/ PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual www.robertshaw.com 2016 Robertshaw 01/16 352-00244-001 IMPORTANT SAFETY INFORMATION WARNING: ELECTRICAL SHOCK HAZARD

More information