Size: px
Start display at page:

Download ""

Transcription

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15 UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E56070 CHI MEI CORPORATION 59-1 SAN CHIA, JEN TE, TAINAN HSIEN 717 TW PA-765A(+) Acrylonitrile Butadiene Styrene (ABS), "Polylac", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL 1.5 V V-0, 5VB V-0, 5VA V-0, 5VA Comparative Tracking Index (CTI): 1 Dimensional Stability (%): - High-Voltage Arc Tracking Rate (HVTR): 2 High Volt, Low Current Arc Resis (D495): 7 Dielectric Strength (kv/mm): - Volume Resistivity (10 x ohm-cm) : - (+) - Optional prefix or suffix; may be used to denote usage of percent acid scavengers. ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: Last Revised: Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC , IEC Class (color) 1.5 V-1 (ALL) 2.1 V-0, 5VB (ALL) 2.5 V-0, 5VA (ALL) 3.0 V-0, 5VA (ALL) Glow-Wire Flammability (GWFI) IEC C - - Glow-Wire Ignition (GWIT) IEC C - - IEC Comparative Tracking Index IEC Volts (Max) - - IEC Ball Pressure IEC C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m ISO Izod Impact ISO 180 kj/m ISO Charpy Impact ISO kj/m Underwriters Laboratories Inc /6/9

16 UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E56070 CHI MEI CORPORATION 59-1 SAN CHIA, JEN TE, TAINAN HSIEN 717 TW PA-777D Acrylonitrile Butadiene Styrene/Phenyl Maleimide (ABS/PMI), "Polylac", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL HB Comparative Tracking Index (CTI): 1 Dimensional Stability (%): - High-Voltage Arc Tracking Rate (HVTR): 0 High Volt, Low Current Arc Resis (D495): 7 Dielectric Strength (kv/mm): - Volume Resistivity (10 x ohm-cm) : - ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 smallscale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: Last Revised: Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC Class (color) HB75 (ALL) Glow-Wire Flammability (GWFI) IEC C - - Glow-Wire Ignition (GWIT) IEC C - - IEC Comparative Tracking Index IEC Volts (Max) - - IEC Ball Pressure IEC C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m ISO Izod Impact ISO 180 kj/m ISO Charpy Impact ISO kj/m Underwriters Laboratories Inc /4/9

17 UL iq for Plastics 第 1 頁, 共 1 頁 Component - Plastics E41938 E I DUPONT DE NEMOURS & CO INC ENGINEERING POLYMERS, CHESTNUT RUN PLAZA, PO BOX 80713, WILMINGTON DE G33L(+) Polyamide 66 (PA66), glass reinforced, "Zytel", furnished as pellets Min Thk Flame RTI RTI RTI Color (mm) Class HWI HAI Elec Imp Str ALL 0.71 HB HB HB Comparative Tracking Index (CTI): 0 Dimensional Stability (%): 1.1 High-Voltage Arc Tracking Rate (HVTR): 1 High Volt, Low Current Arc Resis (D495): 5 Dielectric Strength (kv/mm): 23 Volume Resistivity (10 x ohm-cm) : 13 (+) - Virgin and regrind up to 50% by weight inclusive, have the same basic material characteristics. NOTE - (1) Material designations that are color pigmented may be followed by suffix letters and numbers. (2) Material designations may be prefixed by "ZYT" for Zytel or "MIN" for Minlon or "ZEN" for Zenite or "DEL" for Delrin or "CRA" for Crastin or "RYN" for Rynite or "THX" for Thermx or "ETPV" for ETPV grades. ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 smallscale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. Report Date: Last Revised: Underwriters Laboratories Inc IEC and ISO Test Methods Thickness Test Name Test Method Units Tested (mm) Value Flammability IEC Class (color) 0.71 HB75 (ALL) 1.5 HB75 (ALL) 3.0 HB40 (ALL) Glow-Wire Flammability (GWFI) IEC C - - Glow-Wire Ignition (GWIT) IEC C - - IEC Comparative Tracking Index IEC Volts (Max) - - IEC Ball Pressure IEC C - - ISO Heat Deflection (1.80 MPa) ISO 75-2 C - - ISO Tensile Strength ISO MPa - - ISO Flexural Strength ISO 178 MPa - - ISO Tensile Impact ISO 8256 kj/m ISO Izod Impact ISO 180 kj/m ISO Charpy Impact ISO kj/m Underwriters Laboratories Inc /4/13

UL YELLOW CARD FOR PLASTICS ADD MORE PROPERTIES, WIN NEW CUSTOMERS

UL YELLOW CARD FOR PLASTICS ADD MORE PROPERTIES, WIN NEW CUSTOMERS UL PERFORMANCE MATERIALS UL YELLOW CARD FOR PLASTICS ADD MORE PROPERTIES, WIN NEW CUSTOMERS PERFORMANCE & CERTIFICATION. SIMPLIFIED. As a plastics manufacturer, you undertake rigorous measures to ensure

More information

Lexan* Resin 3412R Europe-Africa-Middle East: COMMERCIAL

Lexan* Resin 3412R Europe-Africa-Middle East: COMMERCIAL LEXAN 3412R is a high viscosity, 20% glass reinforced grade. It offers excellent flame retardancy and is especially designed for applications requiring high rigidity together with high heat. MECHANICAL

More information

Lexan* Resin 121 Europe-Africa-Middle East: COMMERCIAL

Lexan* Resin 121 Europe-Africa-Middle East: COMMERCIAL LEXAN 121 is a low viscosity multi purpose grade available in transparent, translucent and opaque colours. MECHANICAL Taber Abrasion, CS-17, 1 kg 10 mg/1000cy SABIC Method Tensile Stress, yield, 50 mm/min

More information

Supporting Product Innovation

Supporting Product Innovation UL Performance Materials Supporting Product Innovation in the Electrical and Electronics Industry The electrical and electronics (E&E) industry has always relied on highperformance materials, and turned

More information

HIGHTECH THERMOPLASTICS ENERGIZED BY

HIGHTECH THERMOPLASTICS ENERGIZED BY HIGHTECH THERMOPLASTICS ENERGIZED BY High-Tech Thermoplastics for the E&E Industry Standards, Testing, Materials, Applications This information and our technical advice - whether verbal, in writing or

More information

MN-3600H. Panlite. Technical note. Non-halogen PC high-resistant grade. (Comparison of MN-3600H with an company s heat resistant grade:a

MN-3600H. Panlite. Technical note. Non-halogen PC high-resistant grade. (Comparison of MN-3600H with an company s heat resistant grade:a No.J-MN-017 Apr. 13. 2004 Panlite Non-halogen PC high-resistant grade MN-3600H (Comparison of MN-3600H with an company s heat resistant grade:a Technical note TEIJIN CHEMICALS LTD. 1.Introduction Panlite

More information

D U R ETHAN AND POCAN F OR THE ELECTRI CAL IN D U STRY N EW HALOGE N-FRE E FLAME-RETARDANT

D U R ETHAN AND POCAN F OR THE ELECTRI CAL IN D U STRY N EW HALOGE N-FRE E FLAME-RETARDANT D U R ETHAN POCAN D U R ETHAN AND POCAN F OR THE ELECTRI CAL IN D U STRY N EW HALOGE N-FRE E FLAME-RETARDANT POLYESTER S AND POLYAMI D E S A HALOGE N-FRE E FUTUR E Our flame-retardant polyamides (PA) Durethan

More information

This is a preview - click here to buy the full publication ICS ISBN

This is a preview - click here to buy the full publication ICS ISBN CONSOLIDATED VERSION IEC 60691 Edition 4.1 2019-01 colour inside Thermal-links Requirements and application guide INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.120.50 ISBN 978-2-8322-6430-0 Warning!

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper 23 May 2013 Rev A 503-32020 GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY Background Safety is paramount in the home appliance industry. Due to the possibility of human misapplication, over-current,

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper BACKGROUND: Safety is paramount in the home appliance industry. Due to the possibility of human mis-application, over-current, or short circuit

More information

EU flammability standards and ENFIRO

EU flammability standards and ENFIRO EU flammability standards and ENFIRO Pim Leonards Institute for Environmental Studies, VU University Amsterdam Email: pim.leonards@vu.nl EU research project FP7: 226563 Life Cycle Assessment of Environment-Compatible

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Stable Court Contact: Mark Richens Oakley Tel: +44 (0)1630 658568 Nr Market Drayton Fax: +44 (0)1630 658921 Shropshire E-Mail: mark@cranage.co.uk

More information

The Appendix is an integral part of Certificate of Accreditation No. 104/2015 of

The Appendix is an integral part of Certificate of Accreditation No. 104/2015 of Testing Laboratory locations: 1. Climatic and Corrosion Resistance Testing Laboratory 2. Material Testing Laboratory 3. Testing Laboratory of Camouflage Devices 1. Climatic and Corrosion Resistance Testing

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD First edi tion 19904 O-l 5 Plastics - Prepregs - Bulk moulding compound (BMC) and dough moulding compound (DMC) - Basis for a specification mstiques - Preimpr6giNk - Mdanges Z!I

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5 5 Tech Notes TESTING PROTOCOL Fire Retardant Gel Coats Issue Date: 4/22/2010 Document ID: TN-TS-05A 2010 Interplastic Corporation Testing Protocol

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2595099 (LR 7189-177) Master Contract: 164196 Project: 2697346 Date Issued: January 28, 2014 Issued to: Tyco Electronics Corporation 2901 Fulling Mill Rd Mail Stop

More information

Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito. Matteo Paleari Senior Project Engineer

Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito. Matteo Paleari Senior Project Engineer Criteri di Preselezione in Accordo ad UL 94 e Conformità del Prodotto Finito Matteo Paleari Senior Project Engineer UL and the UL logo are trademarks of UL LLC 2012 Who we are Underwriters Laboratories

More information

Drying your polymer. Why? Surface Moisture Hygroscopic: Hygroscopic: tending to absorb moisture from the air W I T H DRYING TECHNOLOGIES

Drying your polymer. Why? Surface Moisture Hygroscopic: Hygroscopic: tending to absorb moisture from the air W I T H DRYING TECHNOLOGIES Drying your polymer Why? Surface Moisture Hygroscopic: Hygroscopic: tending to absorb moisture from the air W I T H DRYING TECHNOLOGIES Drying your polymer And Because all material manufacturers recommend

More information

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Dryflex FLAM. Halogen-Free Flame Retardant TPEs Dryflex FLAM Halogen-Free Flame Retardant TPEs CONTENTS BRAND NAMES & NOMENCLATURE INTRODUCTION KEY PROPERTIES FLAM 600 SERIES FLAM 700 SERIES TYPICAL APPLICATIONS EXPLANATION OF FLAMMABILITY TESTS PROCESSING

More information

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

ASTM D Horizontal Burning Rate Determination of Marlon FS 1.5mm Clear Polycarbonate Sheet UNCONTROLLED ELECTRONIC COPY ASTM D 635-14 Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet A Report To: Brett Martin Ltd. 24 Roughfort Road Mallusk, Co. Antrim United

More information

UL 94 Flammability Ratings: Introduction

UL 94 Flammability Ratings: Introduction UL 94 Flammability Ratings: Introduction UL intends this standard to serve as a preliminary indication of a plastics acceptability for use as part of a device or appliance with respect to its flammability.

More information

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag STANDARD COLOR CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag TECHNICAL DATA SHEET Revision Number. 1 Last Edited 9. januar 2019 OTHER COLORS MATERIAL Flat band cross linked polyolefin. OPERATING

More information

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.) CTA Bulletin Recommended Loudspeaker Safety Practices An Industry Guideline CTA-CEB19 W-2014 (Formerly CEA-CEB19 W-2014) September 2014 NOTICE Consumer Technology Association (CTA) Standards, Bulletins

More information

TOYOLAC PC//ABS Alloy PX10

TOYOLAC PC//ABS Alloy PX10 TOYOLAC PC//ABS Alloy PX1 Technical Guide for Processing & Molding Toray Plastics (Malaysia) Sdn. Bhd. Penang (Head Office) 2628 MK1,SPT.,Lorong Perusahaan 4, Prai Free Industrial Zone, 136 Prai,Penang,Malaysia.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60455-2 Edition 3.0 2015-06 Resin based reactive compounds used for electrical insulation Part 2: Methods of test INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 17.220.99; 29.035.01

More information

Fires, fire safety and trends.

Fires, fire safety and trends. Gummi Fasern Kunststoffe, 66, No. 4, 2013, pp. 219 223 Fires, fire safety and trends. Regulations, standards and the role of flame retardancy J. H. Troitzsc Fire and Environment Protection Service FEPS,

More information

Technical information

Technical information Quality in Quantity Integrated management system The objective of the Phoenix Contact integrated management system is to coordinate all the requirements regarding products, processes and organization.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. 2 Pine Trees, Chertsey Lane, Staines-upon-Thames. TW18 3HR Unit 8B, B W Estates Oldmixon Crescent Weston-super-Mare North Somerset BS24 9BA Contact: Mr K D James Tel: +44 (0)1934-644866 Fax: +44 (0)1934-413909

More information

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION Thomas Leck, PhD DuPont Fluorochemicals 2010 NEXT ACR Tokyo International Exchange Center 17 Feb 2010 DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

More information

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO SVENSK STANDARD SS-EN ISO 6402-1 Fastställd Utgåva Sida 2001-02-23 2 1 (1+10) Copyright SIS. Reproduction in any form without permission is prohibited. Plastics Acrylonitrile-styreneacrylate (ASA), acrylonitrile-

More information

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS The main advantages of NYLON as a washer material are its resistance to abrasion, repeated impacts, organic solvents, oils, gasoline and temperature extremes. It has good creep resistance (yielding to

More information

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves STANDARD TUBE COLOR ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves TECHNICAL DATA SHEET Revision Number. 1 Last Edited 24. juli 2018 The ZH-2X Heat Shrinkable Wire Markers are made of halogen

More information

Fire Test Methods ASTM NFPA UL ISO IEC

Fire Test Methods ASTM NFPA UL ISO IEC Fire Test Methods ASTM NFPA UL ISO IEC D2859 (Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials) E84 (Standard Test Method for Surface Burning Characteristics

More information

Performance of household electrical appliances-refrigerating. EN Domestic cooking appliances burning gas - Part 1-1: Safety - General

Performance of household electrical appliances-refrigerating. EN Domestic cooking appliances burning gas - Part 1-1: Safety - General IAS Accreditation Number Company Name Address Contact Name TL-601 Baglar Mah. Osmanpasa Cad. No: 95 Is Istanbul Plaza E Girişi 34209 Gunesli Istanbul Turkey Ms. Muge Okumus E&E Section Manager Telephone

More information

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

Market-Leading Non-Metallic Enclosure Brands

Market-Leading Non-Metallic Enclosure Brands A unique SMC system for maximizing polymer chain and crosslink bonding. Up to 60% more UV-resistant compared with other available formulations. Meets UL 94 5V Fire-Retardancy Standards plus NFPA No. 101

More information

PRINTED CIRCUIT BOARDS

PRINTED CIRCUIT BOARDS COMPREHENSIVE COMPLIANCE & PERFORMANCE SOLUTIONS FOR PRINTED CIRCUIT BOARDS SUPPORTING THE SUCCESS AND SAFETY OF PRINTED CIRCUIT BOARDS (PCBs) UL is one of the most recognized and trusted certification

More information

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product Product Description PolyOne is a global polymer solutions provider with the ability to meet regulatory and product specifications globally and offer the widest range of polymer-specific specialty colorant

More information

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Table of Contents Product Description...3 Fire Tape Manufacturer...3 Fire Tape Listed

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wallace Way Tern Valley Business Park Market Drayton Shropshire TF9 3AG Contact: Mark Richens Tel: +44 (0) 1630 658568 E-Mail: mark@cranage.co.uk

More information

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES CREATING TOMORROW S SOLUTIONS MOBILITY e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES THE POWER OF e-mobility The need to develop energy-efficient and environmentallyfriendly drive technologies has

More information

Fire Risks and Safety Standards

Fire Risks and Safety Standards Fire Risks and Safety Standards Florian Reil TÜV Rheinland Group Renewable Energies 51105 Cologne, Germany Phone: + 49 221 806 27 94 Email: Florian.Reil@de.tuv.com Workshop BIPV The Increasing Role of

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Maxwell Road Stevenage Hertfordshire SG1 2EW Contact: Darren Hone Tel: +44 (0)1438 777700 Fax: +44 (0)1438 777800 E-Mail: info@fira.co.uk

More information

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In File E170507 Project 08ME09223 October 7, 2008 REPORT ON UNLISTED COMPONENT - Attachment Plugs, Fuseless For Use Only In APPLICANT'S CLASSIFIED, LISTED OR RECOGNIZED PRODUCTS, SYSTEMS OR COMPONENTS Globtek

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 UL Verification Services Inc. 1559 King Street Enfield, CT 06082 www.ul.com/consumer-products Point of Contact:

More information

Submittal Packages Detailed with Items and Reviewers

Submittal Packages Detailed with Items and Reviewers Submittal Packages Detailed with Items and Reviewers Tenochca Upgrades Project # 2351 San Diego State University 5500 Campanile Drive San Diego, CA 92182 Tel: 619-594-3740 Fax: 0050-211000-0 Fire Protection

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

PLASTICS WORKSHOP ENGINEERED. Learn About Thermoplastics Connect with Experts WESTBOROUGH / MASSACHUSETTS (BOSTON AREA)

PLASTICS WORKSHOP ENGINEERED. Learn About Thermoplastics Connect with Experts WESTBOROUGH / MASSACHUSETTS (BOSTON AREA) ENGINEERED PLASTICS WORKSHOP Learn About Thermoplastics Connect with Experts 2017 WESTBOROUGH / MASSACHUSETTS (BOSTON AREA) YOUR GLOBAL COMPOUNDER OF CUSTOM ENGINEERED THERMOPLASTICS Answers to Your Burning

More information

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction 3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction Automatic reset thermostat designed to meet your specific application requirements. Its patented and tamper proof snap action bi-metal disc provides

More information

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT File E133400 Project 05ME09466 Issued: November 1, 2005 Revised: February, 2009 REPORT On COMPONENT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT TDK-Lambda Americas

More information

Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels

Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels Note: This document is a translation of the Spanish document RP 01.37 rev 9 approved by the Plastics

More information

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA

More information

Flame Retardant Polyethylene Tubing

Flame Retardant Polyethylene Tubing Flame Retardant Polyethylene Tubing Classified Under U.L. 1820. Performance Pipe DRISCOPLEX 2600 Instube Flame Retardant (FR) Polyethylene Tubing For Pneumatic Instrument Controls PERFORMANCE PIPE is the

More information

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions 1/8 Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions Content: 1 Safety advises 2 Usage 3 Construction of the DRG 1200 4 Function 5 Installation, dimensions and hole pattern 6 Technical

More information

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate PL-18354-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 11.12.2018 to 21.12.2022 Date of issue: 11.12.2018 Holder

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

Product Information Motor and machine protection

Product Information Motor and machine protection - Basic information The REISSMANN Sensortechnik heater bands were specifically designed for the electric motor industry. These heater bands are delivered as a finished product, in various combinations,

More information

Two Circuit Heavy Duty Burner Connector

Two Circuit Heavy Duty Burner Connector Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Section Specification for Geotextile Used in Permanent Erosion Control Application

Section Specification for Geotextile Used in Permanent Erosion Control Application Project Name: Project Number: 1 GENERAL Section 02370 Specification for Geotextile Used in Permanent Erosion Control Application 1.1 SECTION INCLUDES A. Geotextile to prevent soil loss resulting in excessive

More information

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement Nr. Material or Product Type of activity Internal reference number 1 Cables of rated voltage up to Electrical test Determining resistance of conductors by means of using DC four-wire connection measurement

More information

Q1000 Series exit Devices

Q1000 Series exit Devices 1 1000 Series exit Devices 1000 Series Exit devices and Trims are designed for new or retrofit installation into other manufacturers devices. Push Bar assembly has smooth and reduced projection minimizes

More information

Jan05 Rev A EC

Jan05 Rev A EC Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

FIRE SAFETY OF ELECTRICAL AND ELECTRONIC EQUIPMENT ICL-IP SOLUTIONS

FIRE SAFETY OF ELECTRICAL AND ELECTRONIC EQUIPMENT ICL-IP SOLUTIONS FIRE SAFETY OF ELECTRICAL AND ELECTRONIC EQUIPMENT ICL-IP SOLUTIONS 35 Br 79.90 15 P 30.97 12 Mg 24.31 7 N 14.01 Brominated Flame Retardants Phosphorus Flame Retardants Magnesium Flame Retardants Nitrogen

More information

System Management Certifications. Testing processes Control quality laboratory ottobre 2018 P 2

System Management Certifications. Testing processes Control quality laboratory ottobre 2018 P 2 System Management Certifications Testing processes Control quality laboratory ottobre 2018 P 2 Laboratory machine/equipment TYPE OF TEST MACHINE/EQUIPMENT Dimensional ALTIMETER TYPE LINEAR HEIGHT SERIE

More information

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur. First Revision No. 1-NFPA 501-2015 [ Section No. 5.3.1.3 ] 5.3.1.3 The following conditions shall be met when an interior finish material is tested using the test protocol of NFPA 286, Standard Methods

More information

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc. Hydrogen Sensor Testing and Certification 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. Working for a safer world since 1894 2011 Underwriters Laboratories Inc. Overview Introduction

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 118 Lupton Avenue Leeds LS9 6ED Contact: Mr Scott Wiseman Tel: +44 (0)113 248 8830 Fax: +44 (0)113 248 0239 E-Mail: scott@hstts.co.uk Website:

More information

Automatic Waste Water Lifting Unit

Automatic Waste Water Lifting Unit Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins,

More information

Suppression of Class C Fires

Suppression of Class C Fires Suppression of Class C Fires DEVELOPMENT OF A STANDARD PROCEDURE FOR THE EVALUATION OF THE PERFORMANCE OF CLEAN AGENTS March 23, 2007 Mark L. Robin, Ph.D., DuPont Fluoroproducts Bon Shaw and Brad Stilwell,

More information

2017 INDUSTRIAL FAN CATALOG

2017 INDUSTRIAL FAN CATALOG 2017 INDUSTRIAL FAN CATALOG airkinglimited.com TABLE OF CONTENTS Introduction 2 Industrial Grade Drum Fans 3 1/3 HP Industrial Grade Air Circulators 4 Industrial Grade Fan Components 5 1/4 HP Industrial

More information

Flexible Heaters. of Silicone Rubber & Kapton

Flexible Heaters. of Silicone Rubber & Kapton Flexible Heaters INTRODUCTION Durex Industries flexible heating elements are providing customers their optimal thermal solution in over twenty different OEM markets. Durex s unique approach to flexible

More information

SECTION AIR DOORS

SECTION AIR DOORS SECTION 23 34 33 AIR DOORS Berner Series VSA air doors are designed for openings up to 12 ft for environmental separation and up to 10 ft for insect control. Berner Series VSB air doors are designed for

More information

CERAMIC FIBER HEATERS

CERAMIC FIBER HEATERS Introduction to High Temperature eramic Fiber Heaters...4-2 Options and ccessories...4-5 Flat Panel Heaters...4-6 Full ylindrical Shaped Heaters...4-7 Semi-ylindrical Shaped Heaters...4-8 SETION ERMI FIBER

More information

Pneumatic Tubing POLYTUBING O.D. 5/32"

Pneumatic Tubing POLYTUBING O.D. 5/32 Pneumatic Tubing POLYTUBING O.D. 5/32" 1/4" 3/8" 1/2" PART NR COLOR COIL LENGTH MASTER PACK MASTER PACK WT. 1063636 TWIN TUBE 500' 1000' 16# 1063635 BLACK 500' 2000' 17# 1063641 BLUE 500' 2000' 17# 1063765

More information

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014

IAS Accreditation Number Applied Research Laboratories of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014 IAS Accreditation Number Company Name Address Contact Name TL-222 of South Florida, LLC 5371 Northwest 161st Street Miami, Florida 33014 John Lewczak Director of Quality Assurance Telephone (305) 624-4800

More information

This document is a preview generated by EVS

This document is a preview generated by EVS IEC 61730-2 Edition 2.0 2016-08 REDLINE VERSION colour inside Photovoltaic (PV) module safety qualification Part 2: Requirements for testing IEC 61730-2:2016-08 RLV(en) THIS PUBLICATION IS COPYRIGHT PROTECTED

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Element Materials Technology Oil and Gas UK Limited, Trading as ccredited to

More information

Brasch Hazardous Location Unit Heaters

Brasch Hazardous Location Unit Heaters Brasch Hazardous Location Unit Heaters BHUH Features Designed for rugged industrial applications in hazardous locations where the possibility of explosion or fire exists due to the presence of certain

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908

More information

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Product Data Sheet 4114 N/17HH-218. The engineer's choice The engineer's choice 4114 N/17HH-218 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output

More information

Twin radial blower DRG 1200

Twin radial blower DRG 1200 1/7 Twin radial blower DRG 1200 Content: 1 Safety advises 2 Usage 3 Construction of the DRG 1200 4 Function 5 Installation, dimension and hole pattern 6 Technical data 7 Characteristic curve 8 Validation

More information

The Laboratory is qualified to update standards identifying the test procedures.

The Laboratory is qualified to update standards identifying the test procedures. Page 1 of 19 The Laboratory is qualified to update standards identifying the test procedures. Tests: 2/1 Tensile test at ambient temperature IP No. 07002T001 (ČSN EN ISO 6892-1, ČSN EN ISO 15630-1, 2,

More information

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867

TENDER NO. PGVCL/PROC/SMC BOX FOR CT OPERATED METER & Junction Box/867 1.0 SCOPE: SCHEDULE - X TECHNICAL SPECIFICATION FOR SERVICE CONNECTION BOX MADE FROM THERMOSETTING PLASTIC FOR SERVICE CONNECTIONS. 1.1 This specification covers the design, manufacturing and testing of

More information

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE SKAPS INDUSTRIES 335 Athena Drive, Athens, GA 30601 Ph: (706)-354-3700 Fax: (706)-354-3737 Email: contact@skaps.com DROP-IN SPECIFICATIONS SKAPS GEOTEXTILE SUBSURFACE DRAINAGE The following drop-in specification

More information

Ceramic Fiber Heaters. Table Of Contents

Ceramic Fiber Heaters. Table Of Contents Table Of ontents Pictorial Index................. -14 Introduction to High Temperature eramic Fiber Heaters............. 4-2 Options and ccessories............ 4-5 Flat Panel Heaters............... 4-6

More information

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI TECHNICAL MANUAL for FIRE TAPE E-Z TAPING SYSTEM PO BOX 10887 GREEN BAY, WI 54307 800-721-8273 http://www.e-ztape.com Table of Contents Product Description... 3 Fire Tape Manufacturer... 3 Fire Tape Listed

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 52 00.00 40 (November 2017) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 52 00.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B

PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B f- PRESSURE-SENSITIVE TAPE CLOSURE SYSTEMS FOR USE WITH FACTORY-MADE AIR DUCTS- STANDARDS UL 181A AND UL 181B Dwayne Sloan, Engineering Group Leader, Underwriters Laboratories Inc., Research Triangle Park,

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60079-0 Edition 3.1 2000-06 Edition 3:1998 consolidated with amendment 1:2000 Electrical apparatus for explosive gas atmospheres Part 0: General requirements IEC 2000 Copyright

More information

Twin radial blower DRG 730

Twin radial blower DRG 730 1/7 Twin radial blower DRG 730 Content: 1 Part numbers 2 Safety advises 3 Usage 4 Design 5 Function 6 Technical data 7 Dimensions 8 Installation 9 Characteristic curve 10 Validation A U R O R A Konrad

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

Twin-Agent Fire Fighting/Securing Systems Specifications

Twin-Agent Fire Fighting/Securing Systems Specifications Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,

More information

Type approval qualification of Photovoltaic Modules Procedures and test experiences

Type approval qualification of Photovoltaic Modules Procedures and test experiences Type approval qualification of Photovoltaic Modules Procedures and test experiences We Advise. Develop. Facilitate. Inspect. Certificate. Precisely Right. For You. 1 Type approval qualification of Photovoltaic

More information

HOOK-UP AND LEAD WIRE. UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2. AWG Size. Number of Strands. Note: AWG 20 is available upon request.

HOOK-UP AND LEAD WIRE. UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2. AWG Size. Number of Strands. Note: AWG 20 is available upon request. HOOK-UP AND LEAD WIRE PRODUCT DATA Rubber Insulated Wire UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2 Prestolite manufactures a full assortment of standard wire and cable products for the OEM in automotive

More information

PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS

PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS NEMA FB 11 PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS NEMA Standards Publication No. FB 11-2000 Plugs, Receptacles, and Connectors of the Pin and Sleeve Type

More information